ML12199A442

From kanterella
Jump to navigation Jump to search
Tennessee Department of Environment and Conservation Final 303(d) List 2010
ML12199A442
Person / Time
Site: Watts Bar 
Issue date: 08/31/2010
From:
State of TN, Dept of Environment & Conservation
To:
Watts Bar Special Projects Branch
Poole J
References
Download: ML12199A442 (181)


Text

Final YEAR 2010 303(d) LIST August, 2010 TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION Division of Water Pollution Control Planning and Standards Section 6th Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534

Table of Contents Page Guidance for Understanding and Interpreting the Final 303(d) List 1

2010 Public Meeting Schedule 8

Key to the 303(d) List 9

TMDL Priorities 10 Final 2010 303(d) List 11 Barren River Watershed 11 Upper Cumberland Basin 12 Obey River Watershed 14 Cordell Hull Watershed 16 Collins River Watershed 16 Caney Fork River Watershed 18 Old Hickory Watershed 22 Cheatham Reservoir Watershed 24 Stones River Watershed 30 Harpeth River Watershed 34 Barkley Reservoir Watershed 41 Red River Watershed 43 North Fork Holston River Watershed 45 South Fork Holston River Watershed 46 Watauga River Watershed 51 Holston River Basin 54 Upper French Broad River Basin 57 Lower French Broad River Basin 60 Nolichucky River Watershed 64 Upper Tennessee River Basin 73 Little Tennessee River Basin 81 Upper Clinch River Watershed 82 Powell River Watershed 83 Lower Clinch River Watershed 85 Emory River Watershed 89 Lower Tennessee Basin 92 Hiwassee River Watershed 96 Conasauga River Watershed 101 Ocoee River Watershed 102 Sequatchie River Watershed 104 Guntersville Reservoir 106 Wheeler Lake Watershed 108 Elk River Basin 109 Pickwick - Shoal Creek Basin 113 Upper Kentucky Reservoir 114

Table of Contents (cont.)

Duck River Basin 115 Buffalo River 122 Lower Kentucky Reservoir 123 East Fork Clarks River 125 Mississippi River Basin 125 Obion River Basin 127 South Fork Obion River 131 North Fork Forked Deer River 134 South Fork Forked Deer River 141 Hatchie River Basin 145 Loosahatchie River Basin 149 Wolf River Basin 153 Nonconnah Creek 157 APPENDICES Appendix A.

Streams on the 2008 303(d) List That Have 160 Been Delisted in 2010 For Reasons Related to Water Quality Appendix B.

Streams on the 2008 303(d) List That Have 171 Been Delisted in 2010 For Reasons Other Than Water Quality Appendix C.

Federally Listed Endangered Aquatic Species 172 In the State Of Tennessee

1 GUIDANCE FOR UNDERSTANDING AND INTERPRETING THE FINAL 2010 303(d) LIST August, 2010 What Is the 303(d) List and Why Is It Important?

The 303(d) List is a compilation of the streams and lakes in Tennessee that are water quality limited or are expected to exceed water quality standards in the next two years and need additional pollution controls.

Water quality limited streams are those that have one or more properties that violate water quality standards. They are considered impaired by pollution and not fully meeting designated uses.

Additionally, the 303(d) List prioritizes impacted streams for specialized studies called Total Maximum Daily Load (TMDL). In one waterbody, Barkley Reservoir, a Total Maximum Daily Thermal Load study is needed.

The 2010 303(d) List will update and when finalized, will replace the previous one published in 2008.

Once a stream has been placed on the 303(d) List, it is considered a priority for water quality improvement efforts. These efforts include traditional regulatory approaches such as permit issuance, but also include efforts to control pollution sources that have historically been exempted from regulations, such as certain agricultural and forestry activities.

If a stream is impaired, regardless of whether or not it appears on the 303(d) List, the Division cannot authorize additional loadings of the same pollutant(s). It may mean that dischargers will not be allowed to expand or locate on 303(d) listed streams until the sources of pollution have been controlled.

WHATS NEW FOR 2010 Reassessment of Group 1 and Group 2 Watersheds.

In developing the draft 2008 assessment, the Division used all readily available information.

Consistent with the Divisions watershed approach, the major difference between the 2006 and 2008 versions of the List is the reassessment of the Group 1 and 2 watersheds. It is in these areas of the state that the reviewer will note the most significant assessment changes.

When the assessments for the Group 4 watersheds were undertaken in 2006, chemical data were available.

However, many of the RBPIII biological samples had not yet been fully processed. (In an RBPIII survey, invertebrate collections are taken to a laboratory for identification to genera.)

As a result of the departments desire to meet the statutory deadline of April 1, 2006 for completing the assessment, only chemical data could be used in that revision. For Group 4 watersheds, the biological results have now been fully incorporated.

Continued Incorporation of Elements of EPAs Integrated Reporting Guidance.

In the 2010 303(d) List, we have continued the use of EPAs new assessment categories. These categories are explained in more detail on the following page.

2 303(d) ASSESSMENT CATEGORIES USED IN 2010 The assessment categories suggested by EPA have been incorporated into the development of the 2010 303(d) List. Each stream or lake in Tennessee has been placed into one of the following categories.

Category 1 Waterbody or waterbody segment meets all designated uses.

Category 2 Waterbody or waterbody segment meets some designated uses, but data are not available in order to determine whether all uses are being met.

Category 3 Insufficient data exists to determine whether any uses are being met.

Category 4A One or more uses are not being met. However, TMDLs have been completed and approved for all listed pollutants.

Category 4B One or more uses are not being met. However, a TMDL is not needed because compliance with water quality standards will be achieved in the short-term by a more traditional approach, such as permitting or enforcement.

Category 4C One or more uses are not being met. However, the impairment is not being caused by a pollutant.

Category 5 One or more uses are not being met. A TMDL is needed for the listed pollutants.

Notes concerning the above categories:

1. As with the 2008 list, Tennessee has used Category 4C for segments impacted by flow alteration as that is not a pollutant and a TMDL would not be helpful. If commenters suggest additional causes as appropriate for Category 4c, these will be considered on a case-by-case basis. See the Summary of Public Comments and Departmental Responses for additional information.
2. Some streams, including the area directly impacted by the Kingston ash spill, were proposed as Category 4b. These are cases where for on specific streams, traditional approaches such as permitting or enforcement would lead to water quality standards being met in the short-term and a TMDL would not be helpful. Additional streams were suggested for Category 4b, which we have incorporated into the final version.
3. Category 4a was only used for those streams where all TMDLs have been completed. If additional TMDLs were needed in a segment, it was identified as Category 5, even if some TMDLs were approved.

3 How Were the Waters of Tennessee Assessed for this Document?

The assessment of Tennessees waters was based on a water quality evaluation that took place during 2009 and 2010. Water quality data collected at hundreds of streams in Tennessee were compared to existing water quality criteria (Chapter 1200-4-3-.03).

Data were compared to numeric water quality criteria, or in the case of substances with narrative criteria (criteria based on verbal free from statements), data were compared to ecoregion reference stream data from the appropriate sub-ecoregion.

Details of the monitoring design and assessment process are provided in TDECs Quality Assurance Project Plan (QAPP) for 106 Monitoring in the Division of Water Pollution Control. This document is posted on the departments webpage.

Information concerning monitoring design and sampling procedures of the agencies that supplied additional data used in Tennessees assessment process can be requested from the specific agencies.

Which Tennessee Streams Are Not On the 303(d) List?

Streams considered unpolluted (Categories 1 or 2), plus streams that the Division cannot assess due to a lack of water quality information (Category 3), are not found on the List.

Thus, any stream not on the 303(d) List can be assumed to be either unassessed or unpolluted.

On What Basis Can Waterbodies Be Removed From the 303(d) If They Were Listed In a Previous Version?

The 303(d) List is designed to be a flexible document that can be updated as new information becomes available. EPA must approve revisions to the document and has identified several acceptable reasons for removing or delisting a stream from the 303(d) List:

The stream was listed in error originally.

An example of this might be if a water quality standard was improperly applied, such as the wrong hardness was used to calculate metals criteria.

The streams status changes. A waterbody or a portion of a waterbody might be ruled a wet weather conveyance rather than a stream. (Different criteria apply to wet weather conveyances.)

Water quality standards change. The 303(d) is a compilation of streams that violate state water quality standards. If standards change through the triennial review process, the list can be adjusted.

The stream has improved. If the quality of the stream improves and no longer violates criteria for the parameter(s) of concern, the stream can be removed from the List. Documentation of the improvement is necessary.

Appendix A contains a list of the streams approved for delisting due to water quality improvement. A rationale for each delisting is provided.

Appendix B contains any streams being approved for delisting on any basis other than water quality improvement.

4 Did the Division Use All Readily Available Data In the Water Quality Assessment Process?

The Division utilized its own water quality data, plus that collected by other agencies and entities in Tennessee. EPAs STORET database was utilized as a primary source of water quality data.

Additionally, the Tennessee Valley Authority, the U.S. Army Corps of Engineers, and the U.S Geological Survey were contacted/surveyed directly as none of these agencies currently use STORET.

If any citizens or entities has additional data they would like to have incorporated into the statewide assessment, we would welcome an opportunity to review them. In addition to the data, submissions should include detailed location information, plus QA/QC measures taken to ensure data quality. Data submittals specific to a stream segment will be considered a comment for official departmental response.

Are There Any Data Sources That the Division Chose To Not Use in the Assessment Process?

No. We used all the data that were submitted. However, it should be noted that not all data submitted were used to independently list streams as impacted.

Where questions about sampling techniques or analysis methodologies could not be easily resolved, submitted data were used to screen streams for future studies.

As stated previously, if during the review process for the draft 303(d), additional water quality data are brought to our attention, these data will be factored into our final decision concerning the status of specific streams.

See the Summary of Public Comments and Departmental Responses for additional information.

Agency Data Submitted or Obtained for Consideration in the 2010 303(d) Assessment Process Agency Physical Data Biological Data Chemical Data Bacteriological Data US Environmental Protection Agency X

X X

X US Army Corp of Engineers X

X X

Tennessee Valley Authority X

X X

X US Geological Survey X

X X

X Tennessee Wildlife Resources Agency X

X Metro Water Services MS4 Program X

5 What Is the Watershed Cycle?

In 1996, the Division of Water Pollution Control restructured monitoring and permitting activities on a rotating watershed basis.

Each watershed will be examined on a five-year cycle as illustrated by the map on the next page.

A typical cycle will generally include:

Year 1 Hold planning meetings with stakeholders.

Stakeholders include citizens, environmental groups, other governmental agencies, municipalities, industries, and other interested parties.

Develop a monitoring plan.

Year 2 Collect water quality data.

Year 3 Collect water quality data.

Year 4 Water quality assessment activities.

Perform modeling and TMDL generation Year 5 Publish a watershed plan, which includes the proposed actions to be taken to insure that water quality standards will be met. Issue draft NPDES permits and hold public hearings.

Year 6 Issue final permits after comments have been addressed. Begin cycle again in sixth year.

Stream inventoried on the 303(d) List as violating one or more water quality criteria must be scheduled, on some priority basis, to have a TMDL developed to assist in the identification of control strategies.

Planning Review Existing Data Public Outreach Monitoring Strategies and Data Collection Watershed Assessment and Public Update TMDL Development and Wasteload Allocation Draft Management Plans and Draft Permits Public Notice for Plans and Permits NPDES Permits Issued in 6th year START Stakeholder Involvement 8-Digit Hydrologic Units

6

7 What Is a TMDL?

A Total Maximum Daily Load (TMDL) is a study that (1) quantifies the amount of a pollutant in a stream, (2) identifies the sources of the pollutant, (3) and recommends regulatory or other actions that may need to be taken in order for the stream to no longer be polluted. Following are actions that might be recommended:

Re-allocate limits on the sources of pollutants documented as impacting streams. It might be necessary to lower the amount of pollutants being discharged under NPDES permits or to require the installation of other control measures, if necessary, to insure that standards will be met.

For sources the Division does not have regulatory authority over, such as ordinary agricultural and forestry activities, provide information and technical assistance to other state and federal agencies that work directly with these groups to install appropriate BMPs.

Even for impacted streams on the 303(d) List, TMDL development is not considered appropriate for all bodies of water. Additionally, in cases involving pollution sources in other states, the recommendation may be that another state or EPA develops the TMDL.

How Are the TMDLs Prioritized?

Tennessees TMDL prioritization schedule has been based on a 1998 agreement between EPA and the Department. Under this schedule, the Department committed to the development of all TMDLs for 303(d) listed streams by the year 2011. For its part, EPA committed to provide better guidance and new tools for TMDL generation.

A few years later, the same schedule was formalized by being included as part of a Consent Decree between EPA and environmental groups. Thus, for the next two years, the Division has decided to base its TMDL priority for each body of water on the 303(d) List based on the agreement reached with EPA.

How Did Citizens Participate in this Process?

Once the draft 303(d) was published in April, the Division accepted public comments until June 15, 2010.

Additionally, citizens were able to provide verbal comments at a series of public meetings in May. The list of these meetings appears on the next page.

We specifically requested comments or data the public felts were relevant to a listing, or to a stream not currently listed.

We requested that data include some basic information such as detailed station locations and the QA/QC procedures used during the sample collection and analysis process.

Additionally, departmental staff were available to meet with groups or individuals to discuss specific listings.

Following the conclusion of the formal comment period, responses were prepared for each comment. Our responses were included in a companion document that can be found on our webpage.

http://tn.gov/environment/wpc/publicatio ns/

The responses indicated whether or not a revision was made based on the specific comment received. If a comment did not result in a revision, we explained our rationale for not making a change.

8 2010 303(d) List Public Meeting Schedule WATERSHED DATE LOCATION LOCAL TIME Middle Tennessee May 27 Ruth Neff Conference Room 17th Floor, L & C Tower 401 Church Street, Nashville 1:30 pm West Tennessee May 27 Jackson EFO

  • Main Conference Room 1625 Hollywood Drive, Jackson 1:30 pm Southwestern Tennessee June 2 Memphis EFO Conference Room 8383 Wolf Lake Drive, Bartlett 1:30 pm 6:30 pm East Tennessee June 10 Knoxville EFO Main Conference Room 3711 Middlebrook Pike, Knoxville 1:30 pm 6:30 pm Southeastern Tennessee June 10 Chattanooga EFO Main Conference Room 540 McCallie Ave, Chattanooga 1:30 pm The May 27 meeting in Jackson and the June 10 meeting in Chattanooga were video linked with the Nashville and Knoxville meetings, respectively.

9 Key to 303(d) List WATERBODY ID In 1988, the Division divided the states waters into waterbodies and created a database of information about each. Each waterbody has an ID based on EPAs River Reach System. The first eight digits of the ID (after TN) are the USGS HUC Code number. The next three or four digits are the reach number assigned to the stream by EPA. The last four digits is the segment number assigned to each stream section for the Assessment Database (ADB). There is also a GIS coverage for listed streams.

The 303(d) List is sorted in hydrologic order within each major watershed basin. The NRCS watershed number for the segment is available through the ADB.

WATERBODY The name of the main body of water within the waterbody is provided as NAME.

COUNTY The county or counties where the waterbody is located.

MILES/ACRES IMPAIRED If the stream is considered impaired (not meetings water quality standards), the number of impacted miles or acres (according to Reachfile 3) is shown in this column. Lake acres are noted as ac.

CAUSE The pollutant or pollutants exceeding water quality standards is identified.

SOURCE The general source of each pollutant exceeding water quality standards within the waterbody is identified. (For both causes and sources, the Division uses categories provided by EPA in order to be consistent with language used by other states.)

10 TMDL Priorities It should be noted that TMDL priorities are parameter specific and methodologies have not yet been developed for all substances or conditions. Thus a stream that has multiple causes of impairment may be high priority for one cause, but low priority for another.

HIGH (H)

Tools are available to produce the TMDL and the stream is in one of the watersheds being studied in the next two years. The TMDL will be produced in the next two years.

MEDIUM (M)

Tools are available to produce the TMDL, but the stream is not in a watershed being studied in the next two years.

TMDL will be produced in the next five years.

LOW (L)

Tools are not currently available to produce the TMDL and the stream is not in the watershed being studied in the next two years. TMDL will be produced in the next twelve years.

NOT APPLICABLE (NA) 4a - A TMDL has already been completed, submitted to EPA, and approved by EPA.

4b - A TMDL is not needed because a different type of control strategy is in place which will bring about compliance with the criterion in a reasonable amount of time.

4c - The impact to the stream is not being caused by a pollutant.

11 Final Version - YEAR 2010 303(d) LIST FOR THE STATE OF TENNESSEE Barren River Watershed This small basin is USGS Hydrologic Unit Code 05110002 and flows into Kentucky as part of the Barren River watershed.

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05110002 008 - 0550 UNNAMED TRIB TO WEST FORK DRAKES CREEK Sumner 2.7 Flow Alterations NA Upstream Impoundment Randomly selected for Impounded Streams Survey.

Stream is Category 4C.

(Impairment not caused by a pollutant.)

TN05110002 008 - 0600 DONAHO BRANCH Sumner 3.0 Nitrate+Nitrite L Total Phosphorus L Physical Substrate Habitat Alterations H Escherichia coli NA Collection System Failure Urbanized High Density Area Channelization Category 5. (One or more uses impaired.) However, EPA approved a pathogen TMDL which addresses some of the known pollutants.

TN05110002 010 - 0300 DAVIS BRANCH Macon 1.6 Flow Alterations NA Upstream Impoundment Randomly selected for Impounded Streams Survey.

Category 4C. (Impairment nor caused by a pollutant.)

TN05110002 010 - 0500 LITTLE TRAMMEL CREEK Sumner 11.0 Nitrate+Nitrite L Total Phosphorus L Municipal Point Source Stream is Category 5. (One or more uses impaired.)

TN05110002 027 - 0421 TOWN CREEK Macon 3.7 Unionized Ammonia L Nitrate+Nitrite L Total Phosphorus L Low dissolved oxygen L Escherichia coli NA Minor Municipal Point Source Urbanized High Density Area Category 5. (One or more uses impaired.) EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05110002 027 - 0425 WHITE OAK CREEK Macon 3.0 Alteration in stream-side or littoral vegetation M Total Phosphorus L Escherichia coli H Municipal Point Source Urbanized High Density Area Stream is Category 5. (One or more uses impaired.)

TN05110002 031 - 0250 LITTLE TRACE CREEK Clay 7.86 Flow Alterations NA Upstream Impoundment Randomly selected for Impounded Streams Survey.

Category 4C. (Impairment nor caused by a pollutant.)

TN05110002 CTYLKPO_1 000 CITY LAKE PORTLAND Sumner 34 ac Loss of biological integrity due to siltation M Low dissolved oxygen L Nutrients L Taste & odor L Urbanized High Density Area Animal Feeding Area Stream is Category 5. (One or more uses impaired.)

TN05110002 CITYLKW_1 000 CITY LAKE WESTMORELAND Sumner 11.0 ac Nutrients L Low dissolved oxygen L Taste & odor L Pastureland Urbanized High Density Area Stream is Category 5. (One or more uses impaired.)

12 Upper Cumberland Basin This basin contains the following USGS Hydrologic Unit Codes: 05130101 (Clear Creek) and 05130104 (South Fork Cumberland).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE/TMDL Priority Pollutant Source COMMENTS TN05130101 015 - 0600 STRAIGHT CREEK Claiborne 1.40 Loss of biological integrity due to siltation NA Coal Mining Discharges Highway/Road/Bridge Runoff Category 4a. EPA approved a siltation TMDL that addresses the known pollutants.

TN05130101 015 - 0610 ROCK CREEK Claiborne 2.45 Loss of biological integrity due to siltation NA Coal Mining Discharges Highway/Road/Bridge Runoff Category 4a. EPA approved a siltation TMDL that addresses the known pollutants.

TN05130101 015 - 2000 CLEAR FORK Claiborne Campbell 9.65 Loss of biological integrity due to siltation NA Escherichia coli NA Coal Mining Discharges Highway/Road/Bridge Runoff Sources in Other State Septic Tanks Haul roads are a silt source in this watershed. Category 4a.

EPA approved siltation and pathogen TMDLs that address the known pollutants.

TN05130101 016 - 0100 WHITE OAK CREEK Campbell 6.7 Loss of biological integrity due to siltation NA Escherichia coli NA Coal Mining Discharges Abandoned Mining Septic Tanks Category 4a. EPA approved siltation and pathogen TMDLs that address known pollutants.

TN05130101 016 - 0200 DAVIS CREEK Campbell 24.0 Escherichia coli NA Septic Tanks Category 4A. EPA approved a pathogen TMDL which addresses the known pollutant.

TN05130101 016 - 2000 HICKORY CREEK Campbell 9.5 Escherichia coli NA Septic Tanks Pasture Grazing Category 4A. EPA approved a pathogen TMDL which addresses the known pollutant.

TN05130101 046 - 0200 BENNETT FORK Claiborne 11.0 Loss of biological integrity due to siltation NA Coal Mining Discharges Abandoned Mining Highway/Road/ Bridge Runoff Haul roads are a silt source in this area. Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

TN05130101 091 - 0300 LITTLE ELK CREEK Campbell 9.9 Escherichia coli NA Septic Tanks Category 4A. EPA approved a pathogen TMDL which addresses the known pollutant.

TN05130101 091 - 1000 ELK FORK CREEK Campbell 3.9 Loss of biological integrity due to siltation NA Alteration of stream-side or littoral vegetation NA Escherichia coli NA Abandoned Mining Septic Tanks Category 4a. EPA approved siltation/habitat alteration and pathogen TMDLs that address the known pollutants. Stream provides habitat for a federally listed fish, blackside dace (Phoxinus cumberlandensis).

TN05130104 037 - 1510 JOE BRANCH Anderson 1.14 Loss of biological integrity due to siltation NA Abandoned Mining Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

TN05130104 037 - 1511 UNNAMED TRIB TO JOE BRANCH Anderson 1.00 pH H Abandoned Mining Category 5. (One or more uses impaired.)

TN05130104 037 - 1700 SMOKY CREEK Scott 34.1 Loss of biological integrity due to siltation NA Abandoned Mining Silviculture Category 4a. EPA approved a siltation TMDL that addresses the known pollutants.

13 Final 2010 303(d) LIST (Upper Cumberland Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130104 044 - 0500 STRAIGHT FORK Scott 25.4 pH NA Other Anthropogenic Substrate Alterations M Abandoned Mining Channelization Category 5. EPA approved a pH TMDL which addresses some of the known pollutants.

This stream provides habitat for a federally listed fish, blackside dace (Phoxinus cumberlandensis).

TN05130104 048 - 0200 NORTH FORK PINE CREEK Scott 1.5 Escherichia coli NA Septic Tanks Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130104 048 - 0300 LITTON FORK PINE CREEK Scott 2.5 Escherichia coli NA Collection System Failure Septic Tanks Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130104 048 - 0400 EAST FORK PINE CREEK Scott 2.8 Escherichia coli NA Collection System Failure Septic Tanks Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130104 048 - 0410 UNNAMED TRIB TO EAST FORK PINE CREEK Scott 2.4 Escherichia coli NA Collection System Failure Septic Tanks Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130104 048 - 0500 SOUTH FORK PINE CREEK Scott 1.7 Escherichia coli NA Collection System Failure Septic Tanks Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130104 048 - 1000 PINE CREEK Scott 3.2 Escherichia coli NA Minor Municipal Point Source Collection System Failure Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130104 048 - 2000 PINE CREEK Scott 4.1 Creosote L Nitrate+nitrite L Loss of biological integrity due to siltation NA Low dissolved oxygen L Alteration in stream-side or littoral vegetation NA Escherichia coli NA Minor Municipal Point Source Collection System Failure Septic Tanks Channelization Contaminated sediments Water contact advisory.

Superfund site source of organics in sediment.

Category 5. EPA approved pathogen and siltation TMDLs that address some of the known pollutants.

14 Final 2010 303(d) LIST (Upper Cumberland Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130104 048 - 3000 PINE CREEK Scott 3.0 Creosote L Loss of biological integrity due to siltation NA Nitrate+nitrite L Low dissolved oxygen L Physical Substrate Habitat Alterations H Escherichia coli NA Collection System Failure Septic Tanks Channelization Contaminated sediments Water contact advisory.

Superfund site source of organics. Category 5. EPA approved pathogen and siltation TMDLs that address some of the known pollutants.

TN05130104 050 - 0100 EAST BRANCH BEAR CREEK Scott 5.7 Iron NA pH NA Loss of biological integrity due to siltation NA Abandoned Mining Category 4a. EPA approved iron, pH and siltation TMDLs that address the known pollutants.

TN05130104 050 - 1000 BEAR CREEK Scott 1.36 pH NA Loss of biological integrity due to siltation NA Abandoned Mining Category 4a. EPA approved pH and siltation TMDLs that address the known pollutants.

Obey River Watershed This basin contains the following USGS Hydrologic Unit Codes: 05130105 (Obey River)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130105 001 - 1000 OBEY RIVER Clay 6.8 Low dissolved oxygen L Habitat loss due to stream flow alteration NA Upstream Impoundment Impacted by poor quality Dale Hollow Reservoir releases.

Stream is Category 5 overall (one or more uses impaired),

but flow alteration is 4c (impact not caused by a pollutant).

TN05130105 015 - 0300 CUB CREEK Overton 7.2 Manganese NA Iron NA pH NA Abandoned Mining Category 4a. EPA approved a TMDL that addresses the known pollutants.

TN05130105 019 - 0300 ROCKCASTLE CREEK Fentress 8.9 Nutrients L Low DO L Thermal Modifications L Escherichia coli NA Minor Municipal Point Source Urbanized High Density Area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130105 019 - 0710 LITTLE PINEY CREEK Putnam 3.01 Flow Alteration NA Upstream Impoundment State threatened Obey crayfish found in this stream. Category 4C. (Impairment not caused by a pollutant.

15 Final 2010 303(d) LIST (Obey River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130105 019 - 0721 LOOPER BRANCH Overton 1.23 Flow Alteration NA Upstream Impoundment Stream randomly selected for the Impounded Streams Study.

Category 4C. (Impairment not caused by a pollutant.

TN05130105 019 - 0800 CHARLIE BRANCH Overton 0.69 Flow Alteration NA Iron M pH M Manganese M Upstream Impoundment Stream randomly selected for the Impounded Streams Study.

Category 5. Flow alteration is Category 4C. Impairment not caused by a pollutant.

TN05130105 019 - 0900 MEADOW CREEK Putnam Cumberland 19.0 pH M Loss of biological integrity due to siltation M Abandoned Mining Stream is Category 5. (One or more uses impaired.)

TN05130105 019 - 0950 MEADOW CREEK Cumberland 1.4 Low DO M Industrial Permitted Runoff Stream is Category 5. (One or more uses impaired.)

TN05130105 019 - 1300 BIG LAUREL CREEK Fentress Overton 9.2 Iron NA pH NA Abandoned Mining Category 4a. EPA approved iron and pH TMDLs that address the known pollutants.

TN05130105 019 - 1310 LITTLE LAUREL CREEK Fentress Overton 3.6 Iron NA pH NA Abandoned Mining Category 4a. EPA approved iron and pH TMDLs that address the known pollutants.

TN05130105 019 - 1400 BIG PINEY CREEK Fentress Overton 18.6 pH M Loss of biological integrity due to siltation M Abandoned Mining Category 5. TMDLs needed.

TN05130105 019 - 2000 EAST FORK OBEY RIVER Fentress Overton 22.6 Iron M Manganese M pH M Loss of biological integrity due to siltation M Abandoned Mining Category 5. TMDLs needed.

TN05130105 019 - 3000 EAST FORK OBEY RIVER Putnam Overton 11.1 Iron M Manganese M pH M Loss of biological integrity due to siltation M Abandoned Mining Category 5. TMDLs needed.

TN05130105 033 - 1400 TOWN BRANCH Pickett 3.1 Nitrate+Nitrite L Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli NA Minor Municipal Point Source Sludge Undetermined Source Byrdstown area. Category 5.

EPA approved a pathogen TMDL that addresses some of the known pollutants.

16 Cordell Hull Watershed This basin contains the following USGS Hydrologic Unit Codes: 05130106 (Cordell Hull Lake).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130106 007-0500 FLAT CREEK Overton 23.6 Escherichia coli NA Undetermined Source Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130106 007-0700 CARR CREEK Overton 4.5 Low dissolved oxygen L Upstream Impoundment Stream is Category 5. (One or more uses impaired.)

TN05130106 007-0710 TOWN CREEK Overton 6.2 Nutrients L Low dissolved oxygen L Escherichia coli NA Collection System Failure Urbanized High Density Area Category 5. EPA approved a TMDL that addresses some of the known pollutants.

TN05130106 008-1000 BLACKBURN FORK Jackson 15.9 Escherichia coli NA Undetermined Source Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130106 010-2000 SPRING CREEK Putnam Overton 20.7 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130106 018-2000 MILL CREEK Overton 4.3 Flow Alteration NA Upstream Impoundment Category 4C. (Impairment not caused by a pollutant.)

Collins River Watershed This basin contains the following USGS Hydrologic Unit Codes: 05130107 (Collins River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130107 002 - 1000 MOUNTAIN CREEK Warren Cannon 6.92 Loss of biological integrity due to siltation NA Nitrate+Nitrite L Specialty Crop Production Category 5. EPA approved a siltation TMDL that addresses some of known pollutants.

TN05130107 004 - 0100 HICKORY GROVE BRANCH Warren 10.99 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Specialty Crop Production Pasture Grazing Category 4A. Impaired, but EPA approved siltation/habitat alteration TMDLs that address the known pollutants.

TN05130107 006 - 0700 OAKLAND BRANCH Warren 6.3 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Flow Alteration NA Land Development Discharges from MS4 area Category 4A. Impaired, but EPA approved siltation/habitat alteration TMDLs that address the known pollutants. Flow alteration is 4c (impacts not caused by a pollutant.)

17 Final Version 2010 303(d) LIST (Collins River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130107 012 - 0100 LOCKE BRANCH Warren 4.56 Alteration in stream-side or littoral vegetative cover L Loss of biological integrity due to siltation L Pasture Grazing Category 5. TMDLs needed.

TN05130107 012 - 0200 FULTZ CREEK Warren 14.4 Alteration in stream-side or littoral vegetative cover L Loss of biological integrity due to siltation L Silviculture Category 5. TMDLs needed.

TN05130107 012 - 0400 WEST FORK HICKORY CREEK Coffee 54.54 Escherichia coli L Pasture Grazing Category 5. (One or more uses impaired.)

TN05130107 012 - 0410 MEADOW BRANCH Coffee 7.89 Escherichia coli L Pasture Grazing Category 5. (One or more uses impaired.)

TN05130107 016 - 0150 SAVAGE CREEK Grundy Sequatchie 22.1 Flow Alteration NA Upstream Impoundment Category 4c. (Impacts not caused by pollutant.)

TN05130107 016 - 0740 LAUREL CREEK Grundy 3.93 Loss of biological integrity due to siltation L Specialty Crop Production Category 5. TMDL needed.

TN05130107 016 - 2000 COLLINS RIVER Grundy 5.8 Iron M Manganese M pH M Abandoned Mining Stream is Category 5. (One or more uses impaired.)

TN05130107 023 - 0200 DRY CREEK Warren Sequatchie 31.25 Aluminum L Sulfates M pH M Manganese M Iron M Abandoned Mining Stream is Category 5. (One or more uses impaired.)

TN05130107 023 - 0230 HE CREEK Sequatchie 1.45 pH M Manganese M Iron M Coal Mining Permitted Discharge Abandoned Mining Stream is Category 5. (One or more uses impaired.)

TN05130107 023 - 0231 LITTLE HE CREEK Sequatchie 1.98 pH M Manganese M Iron M Coal Mining Permitted Discharge Abandoned Mining Stream is Category 5. (One or more uses impaired.)

TN05130107 023 - 0232 BIG HE CREEK Sequatchie 2.95 pH M Manganese M Iron M Coal Mining Permitted Discharge Abandoned Mining Stream is Category 5. (One or more uses impaired.)

18 Caney Fork River Watershed This basin contains the following USGS Hydrologic Unit Codes: 05130108 (Caney Fork River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130108 001 - 0100 SNOW CREEK Smith 7.6 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Stream is Category 4a, one or more uses impaired. EPA has approved siltation and habitat alteration TMDLs that address the known pollutants.

TN05130108 001 - 0200 FERGUSON BRANCH Smith 5.8 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. EPA has approved a habitat alteration TMDL that addresses the known pollutants.

TN05130108 002 - 0200 GOOSE CREEK Smith 3.14 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Dredge Mining Pasture Grazing Category 4a. EPA approved siltation/habitat alteration TMDLs that address the known pollutants.

TN05130108 002 - 2000 HICKMAN CREEK Smith DeKalb 10.16 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Low dissolved oxygen L Nitrate+Nitrite L Phosphorus L Escherichia coli NA Municipal Point Source Pasture Grazing Stream is Category 5. (One or more uses impaired.) EPA has approved habitat alteration and pathogen TMDLs that address some of the known pollutants.

TN05130108 004 -0110 DRIVERS BRANCH DeKalb 2.79 Loss of biological integrity due to siltation L Hwy/Road/Bridge Construction Stream is Category 5. (One or more uses impaired.)

TN05130108 012 - 1000 CANEY FORK RIVER Smith DeKalb 6.4 Low dissolved oxygen L Flow Alteration NA Thermal modification L Upstream impoundment (Center Hill Reservoir)

Category 5, but flow alteration is 4c (impact not caused by a pollutant). Provides habitat for listed mussels: Oyster mussel (E. capsaeformis),

Cumberland combshell (E.

brevidens), Pink mucket pearly mussel (Lampsilis abrupta),

Dromedary pearly mussel (Dromus dromus), Fanshell (Cyprogenia stegarias),

Clubshell (Pleurobema clava),

Cumberland bean (Villosa trabalis).

TN05130108 024 -1000 ROCKY RIVER Van Buren Warren 8.7 Loss of biological integrity due to siltation NA Dredge Mining Stream is Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

19 Final Version 2010 303(d) LIST (Caney Fork River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130108 024 - 4000 ROCKY RIVER Van Buren Warren 17.0 pH NA Manganese NA Abandoned Mining Category 4a. EPA approved pH and manganese TMDLs that address the known pollutants. Rocky River provides habitat for the federally listed fish, slender chub (Erimystax cahni).

TN05130108 025 - 0200 CLIFF CREEK White 4.7 Escherichia coli H Pasture Grazing Category 5. Needs TMDL.

TN05130108 025 - 0400 HICKORY VALLEY BRANCH White 8.2 Low dissolved oxygen M Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 5. EPA approved a habitat alteration TMDL that addresses some of the known pollutants.

TN05130108 025 - 1000 CANEY FORK RIVER DeKalb White 1.4 Habitat loss due to stream flow alteration NA Upstream Impoundment Category 4c. Impacts not caused by a pollutant. Section of Caney Fork de-watered by Great Falls Reservoir.

TN05130108 027 - 0300 GARDNER CREEK Bledsoe 3.1 Manganese NA Abandoned mining Category 4a. EPA approved a manganese TMDL that addresses the known pollutant.

TN05130108 027 - 0600 FALL CREEK Van Buren 0.5 Flow alteration NA Iron M Physical substrate habitat alterations M Upstream Impoundment Category 5, but flow alteration is 4c (impact not caused by a pollutant). Iron precipitated out of lake coats substrate and causes orange waterfall.

TN05130108 027 - 0750 PINEY CREEK Van Buren 12.28 Iron NA pH NA Physical substrate habitat alterations M Abandoned Mining Category 5. EPA approved pH and iron TMDLs that address some of the known pollutants.

TN05130108 027 - 0850 DRY FORK Van Buren 16.7 Iron NA pH NA Physical substrate habitat alterations M Abandoned Mining Stream is Category 5. EPA approved pH and iron TMDLs that address some of the known pollutants.

TN05130108 033 - 0200 BEAVERDAM CREEK Bledsoe 19.9 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. One or more uses impaired, but EPA approved siltation and habitat alteration TMDLs that address the known pollutants.

TN05130108 033 - 0300 TAFT CREEK Bledsoe 2.0 Aluminum H Nitrate+Nitrite H Phosphorus H Escherichia coli H Municipal Point Source Pasture Grazing Taft Youth Center is the point source. Category 5. TMDLs needed.

20 Final Version 2010 303(d) LIST (Caney Fork River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130108 033 - 0410 MILL CREEK Bledsoe 1.95 Low dissolved oxygen H Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 5. EPA has approved a habitat alteration TMDL that addresses some of the known pollutants.

TN05130108 033 - 0420 BRADDEN CREEK Bledsoe 10.7 Low dissolved oxygen H Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 5. EPA has approved a habitat alteration TMDL that addresses some of the known pollutants.

TN05130108 033 - 2000 BEE CREEK Bledsoe Cumberland 0.57 Aluminum H Nitrate+Nitrite L Phosphorus L Escherichia coli H Municipal Point Source Pasture Grazing Taft Youth Center. Category

5. TMDL needed.

TN05130108 033 - 3000 BEE CREEK Bledsoe Cumberland 16.1 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. One or more uses impaired but EPA has approved siltation/habitat alteration TMDLs that address known pollutants.

TN05130108 036 - 0100 CLIFTY CREEK White 21.4 pH NA Iron NA Manganese H Abandoned Mining Category 5. EPA approved pH and iron TMDLs that address some of the known pollutants.

TN05130108 036 - 0600 DUNCAN CREEK Cumberland 3.58 Low Dissolved Oxygen L Iron H Manganese H Upstream Impoundment Stream is Category 5. TMDLs needed.

TN05130108 036 - 0700 UNNAMED TRIB TO CANEY FORK RIVER Cumberland 3.5 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Unrestricted Cattle Access Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL that addresses the known pollutant.

TN05130108 036 - 0920 FLYNN CREEK Cumberland 2.8 Loss of biological integrity due to siltation NA Landfill Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

TN05130108 036 - 1100 PUNCHEONCAMP CREEK Cumberland 12.8 pH NA Abandoned Mining Category 4a. EPA approved a pH TMDL that addresses the known pollutant.

TN05130108 043 - 0100 CHERRY CREEK White 11.8 Loss of biological integrity due to siltation NA Escherichia coli H Pasture Grazing Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN05130108 043 - 0500 BLUE SPRING CREEK White 10.1 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

TN05130108 043 - 0600 WILDCAT CREEK White 8.1 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

21 Final Version 2010 303(d) LIST (Caney Fork River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130108 043 - 4000 CALFKILLER RIVER Putnam 4.45 Escherichia coli H Collection System Failure Category 5. TMDL needed.

TN05130108 045 - 0100 CANE CREEK Putnam 19.1 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Discharges from MS4 Area Pasture Grazing Category 4a. One or more uses impaired but EPA approved siltation and habitat alteration TMDLs that address the known pollutant.

TN05130108 045 - 0150 CANE CREEK Putnam 12.0 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Discharges from MS4 Area Pasture Grazing Unrestricted Cattle Access Category 4a. One or more uses impaired but EPA approved siltation and habitat alteration TMDLs that address the known pollutants.

TN05130108 045 - 0300 HUDGENS CREEK Putnam 6.7 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Discharges from MS4 Area Pasture Grazing Category 4a. One or more uses impaired but EPA approved pathogen, siltation, and habitat alteration TMDLs that addresses the known pollutants.

TN05130108 045 - 0400 PIGEON ROOST CREEK Putnam 2.4 Nitrate+Nitrite M Phosphorus M Physical substrate habitat alteration NA Escherichia coli NA Municipal Point Source Discharges from MS4 Area Channelization Category 5. EPA approved pathogen and habitat alteration TMDLs that address some of the known pollutants.

TN05130108 045 - 0450 PIGEON ROOST CREEK Putnam 3.2 Nitrate+Nitrite M Phosphorus M Physical substrate habitat alteration NA Escherichia coli NA Discharges from MS4 Area Channelization Category 5. Impaired, but EPA approved habitat alteration and pathogen TMDLs that address some of the known pollutants.

TN05130108 045 - 0500 POST OAK CREEK White 1.36 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. One or more uses impaired but EPA has approved siltation and habitat alteration TMDLs that address the known pollutants.

TN05130108 045 - 1000 FALLING WATER RIVER Putnam White 8.8 Low Dissolved Oxygen L Nitrate+Nitrite M Phosphorus M Loss of biological integrity due to siltation NA Pasture Grazing Municipal Point Source Discharges from MS4 Area Category 5. Impaired, but EPA has approved siltation and habitat alteration TMDLs that address some of the known pollutants.

TN05130108 053 - 1000 TAYLOR CREEK White 31.8 Escherichia coli M Pasture Grazing Category 5. TMDL needed.

22 Final Version 2010 303(d) LIST (Caney Fork River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130108 097 - 2000 MINE LICK CREEK Putnam 4.23 Escherichia coli NA Nitrate+Nitrite M Phosphorus M Collection System Failure Water contact advisory due to Baxter STP overflows.

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130108 684 - 1000 FALL CREEK DeKalb 9.8 Loss of biological integrity due to siltation NA Nutrients M Low dissolved oxygen M Escherichia coli NA Other anthropogenic substrate alterations NA Major Municipal Point Source Upstream Impoundment Category 5. (One or more uses impaired.) EPA approved siltation, pathogen and habitat alteration TMDLs that address some of the known pollutants.

TN05130108 684 - 2000 FALL CREEK DeKalb 6.7 Other anthropogenic substrate alterations NA Urbanized High Density Area Category 4a. EPA approved a habitat alteration TMDL that addresses the known pollutant.

Old Hickory Watershed This basin contains the following USGS Hydrologic Unit Codes: 05130201 (Old Hickory Lake).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130201 001T-0100 RANKIN BRANCH Sumner 3.3 Alteration of stream-side or littoral vegetation H Nutrients L Channelization Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN05130201 001T-0200 TOWN CREEK Sumner 12.1 Loss of biological integrity due to siltation H Other Anthropogenic Habitat Alterations H Discharges from MS4 area Hydromodification Gallatin area impacts. Stream is Category 5. (One or more uses impaired.)

TN05130201 001T-0400 UNNAMED TRIB TO OLD HICKORY RESERVOIR Sumner 2.57 Loss of biological integrity due to siltation H Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN05130201 001T-0900 WILBURN CREEK Smith 9.9 Loss of biological integrity due to siltation H Alteration of stream-side or littoral vegetation H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

23 Final Version 2010 303(d) LIST (Old Hickory Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130201 011-0100 NORTH FORK CEDAR CREEK Wilson 4.2 Loss of biological integrity due to siltation H Other Anthropogenic Habitat Alterations H Highway Construction Land Development Stream is Category 5. (One or more uses impaired.)

TN05130201 011-0200 MIDDLE FORK CEDAR CREEK Wilson 4.3 Loss of biological integrity due to siltation H Other Anthropogenic Habitat Alterations H Highway Construction Land Development Stream is Category 5. (One or more uses impaired.)

TN05130201 011-0400 WILSON CREEK Wilson 8.1 Loss of biological integrity due to siltation H Other Anthropogenic Habitat Alteration H Highway Construction Land Development Stream is Category 5. (One or more uses impaired.)

TN05130201 013-4000 SPRING CREEK Wilson 9.0 Escherichia coli NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130201 015-0200 JOHNSON BRANCH Wilson 7.6 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130201 021-0300 NEAL BRANCH Wilson 3.7 Total Phosphorus M Loss of biological integrity due to siltation H Escherichia coli NA Unrestricted Cattle Access Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130201 021-0400 BEECH LOG CREEK Wilson 8.5 Total Phosphorus M Loss of biological integrity due to siltation H Escherichia coli NA Pasture Grazing Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.)

TN05130201 021 - 2000 ROUND LICK CREEK Wilson 3.96 Nitrate+Nitrite L Loss of biological integrity due to siltation H Low dissolved oxygen L Alteration of stream-side or littoral vegetation H Escherichia coli NA Minor Municipal Point Source Pasture Grazing Area impacts include Watertown STP. Category 5.

(One or more uses impaired.)

EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130201 021 - 3000 ROUND LICK CREEK Wilson 3.16 Loss of biological integrity due to siltation H Alteration of stream-side or littoral vegetation H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN05130201 028-0100 LITTLE GOOSE CREEK Trousdale 12.7 Other Anthropogenic Habitat Alteration H Escherichia coli NA Hydromodification Undetermined Source Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

24 Final Version 2010 303(d) LIST (Old Hickory Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130201 028-0150 LITTLE GOOSE CREEK Trousdale Macon 10.0 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130201 047 - 0100 UNNAMED TRIB TO DRAKES CREEK Sumner 3.16 Alteration of stream-side or littoral vegetation H Discharges from MS4 Area Hendersonville area. Category

5. One or more uses impaired.

TN05130201 047 - 0200 UNNAMED TRIB TO DRAKES CREEK Sumner 6.13 Alteration of stream-side or littoral vegetation H Discharges from MS4 Area Hendersonville area. Category

5. One or more uses impaired.

TN05130201 055-0200 SINKING CREEK Wilson 7.4 Nutrients L Other Anthropogenic Substrate Alterations H Escherichia coli NA Collection System Failure Discharges from MS4 Area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130201 055-0250 SINKING CREEK Wilson 10.0 Alteration in stream-side or littoral vegetative cover H Other Anthropogenic Substrate Alterations H Escherichia coli NA Pasture Grazing Land Development Highway, Road, and Bridge Construction Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130201 055-1000 BARTONS CREEK Wilson 8.0 Escherichia coli NA Collection System Failure Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

Cheatham Reservoir Watershed This basin contains the following USGS Hydrologic Unit Code: 05130202 (Cheatham Lake)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130202 001 - 3000 CHEATHAM RESERVOIR Davidson 994 ac Escherichia coli M Combined Sewer Overflows Discharges from MS4 area Water contact advisory from Bordeaux Bridge to Woodland Street. Stream is Category 5.

(One or more uses impaired.)

TN05130202 001T - 0200 UNNAMED TRIB TO CHEATHAM RES.

Cheatham 2.04 Loss of biological integrity due to siltation H Other Anthropogenic Habitat Alterations H Discharges from MS4 area Ashland City area trib. Stream is Category 5. (One or more uses impaired.)

TN05130202 001T - 0600 UNNAMED TRIB TO CHEATHAM RES.

Davidson 1.0 Iron H Total Dissolved Solids H Landfills Stream is Category 5. (One or more uses impaired.)

TN05130202 001T - 0700 DAVIDSON BRANCH Davidson 2.83 Escherichia coli H Discharges from MS4 area Collection System Failure Stream is Category 5. (One or more uses impaired.)

25 Final Version 2010 303(d) LIST (Cheatham Reservoir Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130202 007 - 0100 SIMS BRANCH Davidson 1.5 Total Phosphorus L Low dissolved oxygen L Other Anthropogenic Habitat Alterations H Escherichia coli NA Discharges from MS4 area Industrial Permitted Stormwater Provides habitat for the federally listed Nashville crayfish (Orconectes shoupi).

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 007 - 0150 SIMS BRANCH Davidson 1.4 Low dissolved oxygen L Other Anthropogenic Habitat Alterations H Discharges from MS4 area Industrial Permitted Stormwater Stream is Category 5. (One or more uses impaired.)

TN05130202 007 - 0300 FINLEY BRANCH Davidson 1.2 Escherichia coli NA Other Anthropogenic Habitat Alterations H Discharges from MS4 area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 007 - 0600 COLLINS CREEK Davidson 6.7 Alteration of stream-side or littoral vegetation H Loss of biological integrity due to siltation H Discharges from MS4 area Land Development Provides habitat for the federally listed Nashville crayfish (O. shoupi). Category

5. One or more uses impaired.

TN05130202 007 - 0700 TURKEY CREEK Davidson 1.6 Loss of biological integrity due to siltation H Land Development Stream is Category 5. (One or more uses impaired.)

TN05130202 007 - 0800 INDIAN CREEK Davidson 5.7 Total Phosphorus L Escherichia coli H Discharges from MS4 area Undetermined Source Provides habitat for the federally listed Nashville crayfish (O. shoupi). Category 5, one or more uses impaired.

TN05130202 007 - 0900 OWL CREEK Williamson Davidson 11.8 Total Phosphorus L Loss of biological integrity due to siltation H Alteration of stream-side or littoral vegetation H Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN05130202 007 - 0920 UNNAMED TRIB TO OWL CREEK Williamson 1.6 Loss of biological integrity due to siltation H Other Anthropogenic Habitat Alterations H Land Development Stream is Category 5. (One or more uses impaired.)

TN05130202 007 - 0930 UNNAMED TRIB TO OWL CREEK Williamson 2.6 Escherichia coli L Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN05130202 007 - 1000 MILL CREEK Davidson 3.5 Total Phosphorus L Loss of biological integrity due to siltation H Low dissolved oxygen L Collection System Failure Discharges from MS4 area Federally listed Nashville crayfish (O. shoupi). Stream is Category 5. (One or more uses impaired.)

TN05130202 007 - 1100 HOLT CREEK Davidson Williamson 6.2 Loss of biological integrity due to siltation H Escherichia coli L Land Development Undetermined Source Stream is Category 5. (One or more uses impaired.)

26 Final Version 2010 303(d) LIST (Cheatham Reservoir Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130202 007 - 1200 WHITTEMORE BRANCH Davidson 2.9 Other Anthropogenic Habitat Alterations H Discharges from MS4 area Federally listed Nashville crayfish (O. shoupi). Category 5, one or more uses impaired.

TN05130202 007 - 1300 SORGHUM BRANCH Davidson 3.1 Loss of biological integrity due to siltation H Other Anthropogenic Habitat Alterations H Discharges from MS4 area Provides habitat for the federally listed Nashville crayfish (O. shoupi). Category 5, one or more uses impaired.

TN05130202 007 - 1400 SEVENMILE CREEK Davidson 2.4 Low Dissolved Oxygen M Total Phosphorus L Other Anthropogenic Habitat Alterations H Escherichia coli NA Discharges from MS4 area Provides habitat for the federally listed Nashville crayfish (O. shoupi). Category

5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 007 - 1410 SHASTA BRANCH Davidson 1.0 Escherichia coli NA Discharges from MS4 area Collection System Failures Federally listed Nashville crayfish (O. shoupi). Category 4a, EPA approved a pathogen TMDL that addresses the known pollutants TN05130202 007 - 1450 SEVENMILE CREEK Davidson 2.0 Total Phosphorus L Escherichia coli NA Discharges from MS4 area Federally listed Nashville crayfish (O. shoupi). Category

5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 007 - 1490 CATHY JO BRANCH Davidson 1.1 Nutrients L Other Anthropogenic Substrate Alterations H Loss of biological integrity due to siltation H Manure Runoff Upstream Impoundments Animal Feeding Areas Nashville Zoo is in watershed.

Stream is Category 5. (One or more uses impaired.)

TN05130202 007 - 1500 PAVILLION BRANCH Davidson 1.3 Escherichia coli NA Discharges from MS4 area Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130202 007 - 2000 MILL CREEK Davidson 4.0 Loss of biological integrity due to siltation H Low dissolved oxygen M Nutrients L Collection System Failure Discharges from MS4 area Federally listed Nashville crayfish (O. shoupi). Category

5. TMDL needed.

TN05130202 007 - 3000 MILL CREEK Davidson 5.9 Loss of biological integrity due to siltation H Nutrients L Low dissolved oxygen M Collection System Failure Discharges from MS4 area Habitat for the federally listed Nashville crayfish (O. shoupi).

Category 5. TMDL needed.

TN05130202 007 - 5000 MILL CREEK Davidson Williamson 8.1 Total Phosphorus L Loss of biological integrity due to siltation H Low dissolved oxygen H Unrestricted Cattle Access Provides habitat for the federally listed Nashville crayfish (O. shoupi). Category 5, one or more uses impaired.

27 Final Version 2010 303(d) LIST (Cheatham Reservoir Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130202 010 - 0100 EATON CREEK Davidson 7.9 Alteration in stream-side or littoral vegetation H Loss of biological integrity due to siltation H Land Development Stream is Category 5. (One or more uses impaired.)

TN05130202 010 - 0200 DRAKES BRANCH Davidson 2.7 Escherichia coli NA Collection System Failure Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130202 010 - 0700 LITTLE CREEK Davidson 6.06 Alteration in stream-side or littoral vegetation H Loss of biological integrity due to siltation H Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN05130202 010 - 0800 EWING CREEK Davidson 17.6 Other Anthropogenic Habitat Alterations H Discharges from MS4 area Municipal High Density Area Stream is Category 5. (One or more uses impaired.)

TN05130202 010 - 1000 WHITES CREEK Davidson 2.9 Escherichia coli NA Nutrients L Collection System Failure Water contact advisory.

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 014 - 0900 BLUE SPRING CREEK Cheatham 9.8 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130202 023 - 0100 EAST FORK BROWN'S CREEK Davidson 2.2 Nitrate+Nitrite L Total Phosphorus L Other Anthropogenic Habitat Alterations H Escherichia coli NA Oil and Grease L Minor Industrial Point Source Discharges from MS4 area Municipal High Density Area Impacted by spills and runoff from Radnor Yards. Category

5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 023 - 0200 MIDDLE FORK BROWN'S CREEK Davidson 3.5 Nitrate+Nitrite L Total Phosphorus L Other Anthropogenic Habitat Alterations H Escherichia coli NA Discharges from MS4 area Failing Collection System Land Development Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 023 - 0300 WEST FORK BROWN'S CREEK Davidson 3.6 Nitrate+Nitrite M Total Phosphorus M Escherichia coli NA Discharges from MS4 area Failing Collection System Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 023 - 1000 BROWN'S CREEK Davidson 0.2 Nitrate+Nitrite L Total Phosphorus L Other Anthropogenic Habitat Alterations H Escherichia coli NA Oil and Grease L Minor Industrial Point Source Collection System Failure Discharges from MS4 area Municipal High Density Area Water contact advisory.

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

28 Final Version 2010 303(d) LIST (Cheatham Reservoir Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130202 023 - 2000 BROWN'S CREEK Davidson 4.1 Nitrate+Nitrite L Total Phosphorus L Other Anthropogenic Habitat Alterations H Escherichia coli NA Oil and Grease L Minor Industrial Point Source Discharges from MS4 area Municipal High Density Area Water contact advisory.

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 027 - 1000 DRY CREEK Davidson 0.5 Escherichia coli NA Collection System Failure Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130202 027 - 2000 DRY CREEK Davidson 5.9 Other Anthropogenic Habitat Alterations H Municipal High Density Area Stream is Category 5. (One or more uses impaired.)

TN05130202 202 - 1000 PAGES BRANCH Davidson 5.11 Escherichia coli NA Discharges from MS4 area Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130202 209 - 1000 COOPER CREEK Davidson 3.9 Other Anthropogenic Habitat Alterations H Escherichia coli NA Discharges from MS4 area Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN05130202 211 - 1000 LOVES BRANCH Davidson 2.0 Other Anthropogenic Habitat Alterations H Municipal High Density Area Stream is Category 5. (One or more uses impaired.)

TN05130202 212 - 0100 NEELEYS BRANCH Davidson 1.7 Escherichia coli NA Discharges from MS4 area Category 4a. Approved pathogen TMDL addresses the known pollutants.

TN05130202 212 - 1000 GIBSON CREEK Davidson 3.7 Habitat loss due to stream flow alteration NA Other Anthropogenic Habitat Alterations H Escherichia coli NA Discharges from MS4 area Hydromodification Category 5. Flow alteration is 4c (impact not caused by a pollutant). Approved pathogen TMDL addresses some of the known pollutants.

TN05130202 220 - 0100 LUMSLEY FORK Davidson 4.7 Escherichia coli NA Undetermined Source Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130202 220 - 0200 WALKERS CREEK Davidson 6.49 Escherichia coli NA Undetermined Source Category 4a. Approved pathogen TMDL addresses the known pollutant.

TN05130202 220 - 0210 UNNAMED TRIB TO WALKERS CREEK Davidson 1.47 Flow Alteration NA Upstream Impoundment Randomly selected for Impounded Streams Study.

Category 4C. Impairment not caused by a pollutant.

TN05130202 220 - 0300 SLATERS CREEK Sumner 11.3 Loss of biological integrity due to siltation H Escherichia coli NA Sand/Gravel/Rock Quarry Discharges from MS4 area Bank Modification Category 5. Approved pathogen TMDL addresses some of the known pollutants.

29 Final Version 2010 303(d) LIST (Cheatham Reservoir Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130202 220 - 0400 MADISON CREEK Sumner 14.4 Loss of biological integrity due to siltation H Land Development Stream is Category 5. (One or more uses impaired.)

TN05130202 220 - 1000 MANSKERS CREEK Davidson Sumner 7.9 Loss of biological integrity due to siltation H Escherichia coli NA Discharges from MS4 area Land Development Water contact advisory.

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 220 - 2000 MANSKERS CREEK Davidson Sumner 7.6 Loss of biological integrity due to siltation H Escherichia coli NA Discharges from MS4 area Land Development Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 314 - 0300 BOSLEY SPRINGS BRANCH Davidson 1.5 Nitrate+Nitrite L Other Anthropogenic Habitat Alterations H Escherichia coli NA Discharges from MS4 area Municipal High Density Area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 314 - 0400 SUGARTREE CREEK Davidson 4.3 Nutrients L Other Anthropogenic Habitat Alterations H Escherichia coli NA Discharges from MS4 area Municipal High Density Area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130202 314 - 0700 VAUGHNS GAP BRANCH Davidson 0.6 Other Anthropogenic Habitat Alterations H Escherichia coli NA Collection System Failure Municipal High Density Area Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN05130202 314 - 0750 VAUGHNS GAP BRANCH Davidson 1.9 Other Anthropogenic Habitat Alterations H Escherichia coli NA Discharges from MS4 area Municipal High Density Area Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN05130202 314 - 0800 JOCELYN HOLLOW BRANCH Davidson 2.0 Escherichia coli NA Discharges from MS4 area Category 4a. Approved pathogen TMDL addresses the known pollutants.

TN05130202 314 - 1000 RICHLAND CREEK Davidson 1.9 Escherichia coli NA Total Phosphorus L Other Anthropogenic Habitat Alterations H Collection System Failure Municipal High Density Area Advisory due to Metro collection system overflows.

Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN05130202 314 - 2000 RICHLAND CREEK Davidson 6.7 Escherichia coli NA Total Phosphorus L Other Anthropogenic Habitat Alterations H Collection System Failure Discharges from MS4 area Municipal High Density Area Advisory due to Metro collection system overflows.

Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN05130202 314 - 3000 RICHLAND CREEK Davidson 4.0 Total Phosphorus L Other Anthropogenic Habitat Alterations H Discharges from MS4 area Municipal High Density Area Stream is Category 5. (One or more uses impaired.)

30 Stones River Watershed This basin contains the following USGS Hydrologic Unit Code: 05130203 (Stones River)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130203 001 - 0100 MCCRORY CREEK Davidson 1.4 Nitrate+Nitrite NA Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli NA Highway, Roads, Bridges, Infrastructure Construction Discharges from MS4 Area Collection System Failure This stream is Category 4a.

Impaired, but EPA approved nutrient, siltation/habitat alteration and pathogen TMDLs that address the known pollutants.

TN05130203 001 - 0150 MCCRORY CREEK Davidson 10.7 Nitrate+Nitrite NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Discharges from MS4 Area Category 4a. EPA approved a nutrient and siltation/ habitat alteration TMDLs that address the known pollutants.

TN05130203 001 - 1000 STONES RIVER Davidson 6.7 Sulfide-hydrogen sulfide L Low dissolved oxygen L Habitat loss due to stream flow alteration NA Odor threshold number L Upstream Impoundment Category 5 overall, but flow alteration is 4c (impact not caused by a pollutant).

Sulfides cause odor problem below dam.

TN05130203 003T - 0100 FINCH BRANCH Rutherford 5.7 Nutrients L Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli NA Land Development Collection System Failure Category 5. EPA approved pathogen and habitat alteration TMDLs that address some of the known pollutants in this stream.

TN05130203 010 - 0100 ROCKY FORK CREEK Rutherford 7.4 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Land Development Category 4a. EPA approved a siltation/ habitat alteration TMDL that addresses the known pollutant in this stream.

TN05130203 010 - 0200 OLIVE BRANCH Rutherford 8.1 Physical substrate habitat alterations NA Land Development Category 4a. EPA approved a habitat alteration TMDL that addresses the known pollutants in this stream.

TN05130203 010 - 0300 HARTS BRANCH Rutherford 3.9 Loss of biological integrity due to siltation NA Discharges from MS4 area Category 4a. EPA has approved a siltation TMDL that addresses the known pollutant.

TN05130203 010 - 0310 ROCK SPRING BRANCH Rutherford 5.6 Loss of biological integrity due to siltation NA Physical substrate habitat alterations NA Highways, Roads, Bridges, Infrastructure Construction Land Development Category 4a. EPA approved a siltation/ habitat alteration TMDLs that address known pollutants in this stream.

31 Final Version 2010 303(d) LIST (Stones River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130203 010 - 1000 STEWARTS CREEK Rutherford 7.0 Nitrate+Nitrite L Total Phosphorus L Loss of biological integrity due to siltation NA Municipal Point Source Discharges from MS4 area Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants in this stream.

TN05130203 010 - 2000 STEWARTS CREEK Rutherford 5.5 Escherichia coli H Discharges from MS4 area Category 5. TMDLs needed.

TN05130203 018 - 0100 SINKING CREEK Rutherford 5.5 Alteration in stream-side or littoral vegetative cover M Escherichia coli NA Land Development Discharges from MS4 area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130203 018 - 0210 CHRISTMAS CREEK Rutherford 12.3 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130203 018 - 2000 WEST FORK STONES RIVER Rutherford 1.3 Nitrate+Nitrite L Total Phosphorus L Loss of biological integrity due to siltation M Municipal Point Source Land Development Category 5. The stream is impaired for one or more uses.

TN05130203 018 - 3000 WEST FORK STONES RIVER Rutherford 5.1 Loss of biological integrity due to siltation M Discharges from MS4 area Category 5. The stream is impaired for one or more uses.

TN05130203 018 - 7000 WEST FORK STONES RIVER Rutherford 7.2 Low dissolved oxygen NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130203 022 -0100 TOWN CREEK (formerly Unnamed Trib to Lytle Creek)

Rutherford 0.13 Low dissolved oxygen NA Escherichia coli NA Undetermined Source Category 4a. EPA approved a dissolved oxygen and pathogen TMDL that addresses the known pollutant.

TN05130203 022 -0200 LEES SPRING BRANCH Rutherford 1.1 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Land Development Category 4A. EPA approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130203 022 -1000 LYTLE CREEK Rutherford 8.9 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Discharges from MS4 area Category 4a. Impaired, but EPA approved siltation/habitat alteration and pathogen TMDLs that address the known pollutants.

TN05130203 022 -2000 LYTLE CREEK Rutherford 10.1 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Land Development Category 4a. Impaired, but EPA approved TMDLs that address known pollutants.

32 Final Version 2010 303(d) LIST (Stones River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130203 023 -0210 UNNAMED TRIB TO BUSHMAN CREEK Rutherford 0.37 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Physical Substrate Habitat Alteration NA Loss of biological integrity due to siltation NA Discharges from MS4 area Channelization This stream is Category 4A.

The stream is impaired, but EPA has approved a TMDL for the known pollutants.

TN05130203 023 -0310 BEAR BRANCH Rutherford 3.5 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Nutrients NA Pasture Grazing Land Development Category 4a. EPA approved nutrient and siltation/ habitat alteration TMDLs that address the known pollutants in this stream.

TN05130203 025 -2000 CRIPPLE CREEK Rutherford 5.4 Loss of biological integrity due to siltation NA Pasture Grazing This stream is Category 4A.

Impaired, but EPA approved a siltation TMDL for the known pollutant.

TN05130203 026 - 2000 EAST FORK STONES RIVER Cannon 6.5 Escherichia coli H Pasture Grazing This stream is Category 5.

TMDLs needed.

TN05130203 029 - 0100 JARMAN BRANCH Rutherford Wilson 4.4 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Nutrients NA Pasture Grazing Land Development Category 4a. Impaired, but EPA has approved nutrient and siltation/ habitat alteration TMDLs that address the known pollutants in this stream.

TN05130203 029 - 0200 UNNAMED TRIB TO BRADLEY CREEK Rutherford 2.7 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Nutrients NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved nutrient and siltation/ habitat alteration TMDLs that address known pollutants.

TN05130203 029 - 0300 UNNAMED TRIB TO BRADLEY CREEK Rutherford 1.7 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Nutrients L Pasture Grazing Unrestricted Cattle Access This stream is Category 5.

Impaired, but EPA has approved a siltation/ habitat alteration TMDL that addresses some of the known pollutants in this stream.

33 Final Version 2010 303(d) LIST (Stones River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130203 032 - 0200 CEDAR CREEK Wilson 1.7 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Unrestricted Cattle Access This stream is Category 4A.

The stream is impaired, but EPA has approved a siltation/

habitat alteration TMDL for the known pollutants.

TN05130203 035 - 0100 SCOTTS CREEK Davidson 4.7 Nitrate+Nitrite L Total Phosphorus L Loss of biological integrity due to siltation NA Discharges from MS4 area Category 5. EPA has approved a siltation/ habitat alteration TMDL.

TN05130203 035 - 0300 DRY FORK CREEK Davidson 5.0 Loss of biological integrity due to siltation NA Discharges from MS4 area Category 4A. Impaired, but EPA has approved a siltation/

habitat alteration TMDL for the known pollutants.

TN05130203 035 - 0400 UNNAMED TRIB TO STONERS CREEK Davidson 1.4 Loss of biological integrity due to siltation NA Industrial Stormwater Discharge This stream is Category 4A.

The stream is impaired, but EPA has approved a siltation/

habitat alteration TMDL for the known pollutants.

TN05130203 035 - 1000 STONERS CREEK Davidson 1.9 Loss of biological integrity due to siltation NA Escherichia coli NA Land Development Collection System Failure This stream is Category 4a.

Impaired, but EPA has approved a siltation/ habitat alteration and pathogen TMDL that addresses the known pollutants in this stream.

TN05130203 036 - 0100 EAST BRANCH HURRICANE CREEK Rutherford 7.3 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Discharges from MS4 area Channelization This stream is Category 4A.

The stream is impaired, but EPA has approved a siltation/

habitat alteration TMDL for the known pollutants.

TN05130203 036 - 0200 WEST BRANCH HURRICANE CREEK Rutherford Davidson 3.5 Nutrients NA Loss of biological integrity due to siltation NA Land Development Category 4a. EPA approved nutrient and siltation/habitat alteration TMDLs that address the known pollutants.

TN05130203 036 - 1000 HURRICANE CREEK Rutherford Davidson 8.5 Nutrients NA Loss of biological integrity due to siltation NA Escherichia coli H Industrial Point Source Land Development Discharges from MS4 area Category 5. EPA approved a nutrient and siltation/ habitat alteration TMDLs that address some of the known pollutants.

TN05130203 230 - 0100 NORTH CREEK Wilson 2.1 Loss of biological integrity due to siltation H Land Development Category 5. TMDLs needed.

34 Final Version 2010 303(d) LIST (Stones River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130203 232 - 0100 NORTH FORK SUGGS CREEK Wilson 9.2 Habitat loss due to alteration in stream-side or littoral vegetative cover H Nutrients L Loss of biological integrity due to siltation M Pasture Grazing Discharges from MS4 area Category 5. TMDLs needed.

TN05130203 232 - 1000 SUGGS CREEK Davidson Wilson 18.1 Loss of biological integrity due to siltation H Pasture Grazing This stream is Category 5.

The stream is impaired for one or more uses.

TN05130203 539 - 0100 WEST FORK HAMILTON CREEK Davidson 1.8 Alteration in stream-side or littoral vegetative cover H Loss of biological integrity due to siltation H Discharges from MS4 area Loss of Riparian Habitat This stream is Category 5.

The stream is impaired for one or more uses.

TN05130203 539 - 1000 EAST FORK HAMILTON CREEK Davidson 6.0 Physical substrate habitat alterations H Loss of biological integrity due to siltation H Channelization Land Development This stream is Category 5.

The stream is impaired for one or more uses.

Harpeth River Watershed This basin contains the following USGS Hydrologic Unit Code: 05130204 (Harpeth River)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130204 001 -0700 TRACE CREEK Cheatham Dickson 8.3 Escherichia coli NA Collection System Failure Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130204 002 -0200 UNNAMED TRIB. TO JONES CREEK Dickson 6.48 Flow Alterations NA Upstream Impoundments Category 4c. Impacts not caused by a pollutant.

TN05130204 002 -0400 WILL HALL CREEK Dickson 0.96 Escherichia coli NA Pasture Grazing Category 4a. EPA has approved a pathogen TMDL for the known pollutants.

TN05130204 002 -0410 CREECH HOLLOW CREEK Dickson 0.5 Alteration in stream-side or littoral vegetative cover M Escherichia coli NA Pasture Grazing Category 5. EPA approved a pathogen TMDL for some of the known pollutants.

TN05130204 002 -0600 UNNAMED TRIB. TO JONES CREEK Dickson 0.26 Other anthropogenic substrate alterations NA Loss of biological integrity due to siltation NA Golf Course Upstream Impoundment Category 4a. EPA approved a siltation/ habitat alteration TMDL for the known pollutants.

35 Final Version 2010 303(d) LIST (Harpeth River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130204 002 -0700 SPICER BRANCH Dickson 4.6 Physical substrate habitat alterations NA Loss of biological integrity due to siltation NA Channelization Land Development Category 4a. EPA approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 002 -1300 TOWN CREEK Dickson 7.6 Escherichia coli H Undetermined Source Category 5. TMDL needed.

TN05130204 002 -2000 JONES CREEK Dickson 7.0 Nitrate+Nitrite L Total Phosphorus L Escherichia coli NA Municipal Point Source Pasture Grazing Category 5. EPA approved a pathogen TMDL for some of the known pollutants.

TN05130204 002 -3000 JONES CREEK Dickson 8.1 Nutrients L Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation NA Land Development Pasture Grazing Category 5. EPA approved a siltation/ habitat alteration TMDL for some of the known pollutants in this stream.

TN05130204 006 -0400 UNNAMED TRIB TO BIG TURNBULL CREEK Williamson 0.36 Loss of biological integrity due to siltation NA Undetermined Source Category 4a. EPA approved a siltation TMDL for the known pollutants in this stream.

TN05130204 006 -0400 UNNAMED TRIB TO BIG TURNBULL CREEK Williamson 0.59 Cause Unknown NA Undetermined Source Category 4c. Impact not known to be a pollutant.

TN05130204 006 -1100 NAILS CREEK Dickson 7.6 Loss of biological integrity due to siltation NA Highways, Roads, Bridge, Infrastructure Construction Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN05130204 006 -1230 GUM BRANCH Dickson 2.7 Loss of biological integrity due to siltation NA Highways, Roads, Bridge, Infrastructure Construction Land Development Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN05130204 009 -0200 NEWSOM BRANCH Davidson 1.7 Loss of biological integrity due to siltation NA Discharges from MS4 Area Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN05130204 009 -0400 FLAT CREEK Davidson 3.6 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Discharges from MS4 Area Category 4a. Impaired, but EPA approved a TMDL for the known pollutants.

TN05130204 009 -0500 CARTWRIGHT CREEK Williamson 5.7 Physical substrate habitat alterations NA Land Development Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

36 Final Version 2010 303(d) LIST (Harpeth River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130204 009 -0600 MURRAY BRANCH Williamson 3.6 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. The stream is impaired, but EPA approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 009 -0700 BROWN CREEK Williamson 5.3 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN05130204 009 -0800 UNNAMED TRIB TO HARPETH RIVER Williamson 2.1 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Land Development Category 4a. EPA approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 009 -0900 TRACE CREEK Davidson Williamson 4.9 Physical substrate habitat alteration NA Land Development Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN05130204 009 - 1100 BEECH CREEK Davidson 3.6 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Discharges from MS4 area Category 4a. EPA has approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 009 - 2000 HARPETH RIVER Cheatham Davidson 18.8 Nutrients NA Low dissolved oxygen NA Municipal Point Sources Discharges from MS4 area Category 4a. EPA approved nutrient and DO TMDLs for the known pollutants.

TN05130204 009 - 3000 HARPETH RIVER Davidson Williamson 16.8 Nutrients NA Low dissolved oxygen NA Municipal Point Sources Discharges from MS4 area Category 4a. EPA approved nutrient and DO TMDLs for the known pollutants.

TN05130204 010 - 0200 UNNAMED TRIB TO SOUTH HARPETH RIVER Davidson 1.0 Flow Alteration NA Upstream Impoundment Category 4c. Impact not caused by a pollutant.

TN05130204 010 - 0600 BEDFORD CREEK Williamson 5.67 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. The stream is impaired, but EPA has approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 010 - 0800 ARKANSAS CREEK Williamson 11.17 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

37 Final Version 2010 303(d) LIST (Harpeth River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130204 010 - 1300 HUNTING CAMP CREEK Williamson 9.5 Loss of biological integrity due to siltation NA Land Development Category 4a. Impaired, but EPA approved a TMDL for the known pollutants.

TN05130204 010 -1400 UNNAMED TRIB TO SOUTH HARPETH RIVER Davidson Williamson 1.7 Flow Alteration NA Upstream Impoundment Category 4c. Impact not caused by a pollutant.

TN05130204 013 - 0100 HATCHER SPRING CREEK Williamson 6.5 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Category 5. TMDLs needed.

TN05130204 013 - 0200 POLK CREEK Williamson 8.8 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. The stream is impaired, but EPA approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 013 - 0300 UNNAMED TRIB TO WEST HARPETH RIVER Williamson 1.8 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN05130204 013 - 0400 UNNAMED TRIB TO WEST HARPETH RIVER Williamson 1.3 Loss of biological integrity due to siltation NA Highways, Roads, Bridge, Infrastructure Construction Category 4a. EPA approved a siltation TMDL for the known pollutants.

TN05130204 013 - 0500 KENNEDY CREEK Williamson 4.8 Physical substrate habitat alterations NA Loss of biological integrity due to siltation NA Land Development Category 4a. Impaired, but EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN05130204 013 - 0600 UNNAMED TRIB TO WEST HARPETH RIVER Williamson 6.5 Loss of biological integrity due to siltation NA Land Development Category 4a. EPA approved a siltation TMDL for the known pollutants.

TN05130204 013 - 0700 MURFREES FORK Williamson 6.2 Escherichia coli H Pasture Grazing This stream is Category 5.

TMDL needed.

TN05130204 013 - 0710 RATTLESNAKE BRANCH Williamson 6.5 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Nutrients NA Escherichia coli H Pasture Grazing Category 5. Impaired, but EPA has approved habitat/nutrient TMDLs for some of the known pollutants.

38 Final Version 2010 303(d) LIST (Harpeth River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130204 013 - 0720 CAYCE BRANCH Williamson 5.9 Physical substrate habitat alteration NA Loss of biological integrity due to siltation NA Pasture Grazing Unrestricted Cattle Access Category 4a. Impaired, but EPA has approved a siltation/

habitat alteration TMDL for the known pollutants.

TN05130204 013 - 0730 WEST PRONG MURFREES FORK Williamson 6.0 Escherichia coli NA Pasture Grazing Category 4a. Impaired but EPA approved a pathogen TMDL for the known pollutants TN05130204 013 - 0750 MURFREES FORK Williamson 18.4 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN05130204 013 - 2000 WEST HARPETH RIVER Williamson 10.9 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN05130204 016 - 0100 LYNWOOD CREEK Williamson 5.4 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Land Development Category 4a. Impaired, but EPA has approved a siltation/

habitat alteration TMDL for the known pollutants.

TN05130204 016 - 0200 SPENCER CREEK Williamson 19.9 Loss of biological integrity due to siltation NA Escherichia coli H Land Development Discharges from MS4 Area Category 5. EPA approved a siltation TMDL for some of the known pollutants.

TN05130204 016 - 0210 SOUTH PRONG SPENCER CREEK Williamson 5.76 Loss of biological integrity due to siltation NA Alteration in stream-side or littoral vegetative cover NA Land Development Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN05130204 016 - 0300 LIBERTY CREEK Williamson 0.54 Toluene L Acetone L Low Dissolved Oxygen L Loss of biological integrity due to siltation M Alteration of stream-side or littoral vegetative cover M Industrial Point Source Discharges from MS4 Area Liberty Creek is impacted in part due to accidental releases of toluene and acetone. These substances indirectly affect fish and aquatic life and directly impact the aesthetics of the stream. Category 5.

One or more uses impaired.

TN05130204 016 - 0350 LIBERTY CREEK Williamson 1.31 Loss of biological integrity due to siltation M Alteration of stream-side or littoral vegetation M Discharges from MS4 area This stream is Category 5.

One or more uses impaired.

TN05130204 016 - 0400 WATSON BRANCH Williamson 6.8 Loss of biological integrity due to siltation NA Land Development Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN05130204 016 - 0800 MCCRORY CREEK Williamson 18.5 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

39 Final Version 2010 303(d) LIST (Harpeth River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130204 016 -1000 HARPETH RIVER Williamson 6.8 Low dissolved oxygen NA Phosphorus NA Municipal Point Source Discharges from MS4 area Category 4a. EPA approved DO and nutrient TMDLs for the known pollutants.

TN05130204 016 - 1200 FIVEMILE CREEK Williamson 14.4 Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved siltation and pathogen TMDLs for the known pollutants.

TN05130204 016 - 1300 DONELSON CREEK Williamson 3.4 Loss of biological integrity due to siltation NA Land Development Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN05130204 016 - 1400 UNNAMED TRIB TO HARPETH RIVER Williamson 4.0 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Land Development Category 4a. The stream is impaired, but EPA approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 016 - 1500 SHARPS CREEK (formerly called Sparks Creek)

Williamson 4.9 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Discharges from MS4 area Category 4a. The stream is impaired, but EPA approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 016 - 2000 HARPETH RIVER Williamson 3.9 Low Dissolved Oxygen NA Phosphorus NA Loss of biological integrity due to siltation NA Escherichia coli NA Discharges from MS4 area Highways, Roads, Bridges, Infrastructure Construction Pasture Grazing Category 4a. Impaired, but EPA has approved pathogen, siltation/ habitat alteration, and organic enrichment TMDLs for the known pollutants.

TN05130204 016 - 3000 HARPETH RIVER Williamson 9.0 Low Dissolved Oxygen NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved DO and siltation TMDLs for the known pollutants.

TN05130204 016 - 4000 HARPETH RIVER Williamson 7.5 Low Dissolved Oxygen NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved DO and siltation TMDLs for the known pollutants.

TN05130204 018 - 0200 CONCORD CREEK Rutherford 13.65 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Specialty Crop Production Sod farming is specialty crop.

Category 4a. Impaired, but EPA has approved a siltation/

habitat alteration TMDL for the known pollutants.

TN05130204 018 - 0220 UNNAMED TRIB TO CONCORD CREEK (previously Unnamed Trib to Harpeth River)

Rutherford 1.23 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. Impaired, but EPA has approved a siltation/

habitat alteration TMDL for the known pollutants.

40 Final Version 2010 303(d) LIST (Harpeth River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130204 018 - 0300 KELLEY CREEK Rutherford 5.91 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen and siltation/ habitat alteration TMDLs for the known pollutants.

TN05130204 018 - 0400 CHEATHAM BRANCH Rutherford 3.4 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. The stream is impaired, but EPA approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 018 - 2000 HARPETH RIVER Rutherford 2.7 Lead NA Industrial Point Source Discharge Contaminated Sediment Category 4a. Impaired, but EPA has approved a lead TMDL for the known pollutant.

TN05130204 018 - 3000 HARPETH RIVER Rutherford 7.39 Low Dissolved Oxygen NA Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli H Pasture Grazing Category 5. EPA has approved a siltation/ habitat alteration and organic enrichment TMDL for some of the known pollutants in this stream.

TN05130204 021 - 0100 OTTER CREEK Davidson 4.6 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Land Development Category 4a. The stream is impaired, but EPA has approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 021 - 0200 UNNAMED TRIB TO LITTLE HARPETH RIVER Davidson 4.93 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Land Development Category 4a. The stream is impaired, but EPA has approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 021 - 0300 BEECH CREEK Williamson 7.7 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Land Development Category 4a. The stream is impaired, but EPA has approved a siltation/ habitat alteration TMDL for the known pollutants.

TN05130204 021 - 1000 LITTLE HARPETH RIVER Davidson Williamson 4.1 Low dissolved oxygen NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Land Development Collection System Failure Category 4a. Impaired for one or more uses. However, EPA has approved pathogen, siltation/ habitat alteration, and organic enrichment TMDLs for the known pollutants in this stream.

41 Final Version 2010 303(d) LIST (Harpeth River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130204 021 - 2000 LITTLE HARPETH RIVER Williamson 12.1 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Discharges from MS4Area Collection System Failure Category 4a. Impaired, but EPA has approved siltation/

habitat alteration TMDLs for the known pollutants.

Barkley Reservoir Watershed This basin contains the following USGS Hydrologic Unit Code: 05130205 (Lake Barkley)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130205 015 - 1000 BARKLEY RESERVOIR Stewart Montgomery 20459 ac Low Dissolved Oxygen L Temperature Alterations L Industrial Thermal Discharges Thermal discharges from Cumberland Steam Plant impacted both recreation and aquatic life during the summer of 2007 when reduced flows and elevated ambient temperatures placed stress on the system. Dissolved oxygen levels were depressed well into Kentucky. However, upstream of the steam plant, water quality standards were maintained Category 5 (One or more uses impaired.)

According to the Clean Water Act, since the Balanced and Indigenous Population (BIP) requirement was not maintained, a Total Maximum Daily Thermal Load study is required.

42 Final Version 2010 303(d) LIST (Barkley Reservoir Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE (Pollutant)

Pollutant Source COMMENTS TN05130205 015T - 1100 WALL BRANCH Montgomery 4.8 Nitrate+Nitrite L Escherichia coli NA Collection System Failure Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130205 015T - 1900 BUDDS CREEK Montgomery 13.9 Alteration in stream-side or littoral vegetation M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN05130205 015T - 1910 ANTIOCH CREEK Montgomery 15.8 Alteration in stream-side or littoral vegetation M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN05130205 020 - 1000 EAST FORK YELLOW CREEK Montgomery 5.5 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutants in this stream.

TN05130205 024 - 0600 LITTLE BARTONS CREEK Montgomery Dickson 35.1 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN05130205 038 - 0100 LITTLE MCADOO CREEK Montgomery 14.8 Escherichia coli H Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN05130205 038 - 2000 BIG MCADOO CREEK Montgomery 5.8 Loss of biological integrity due to siltation M Nutrients L Escherichia coli H Nonirrigated Crop Production Land Development Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN05130205 110 - 0300 BARTEE BRANCH Montgomery 5.71 Low Dissolved Oxygen L Flow Alterations NA Upstream Impoundment Randomly selected for Impounded Stream Study.

Category 5. However, flow alteration is 4C (not a pollutant).

TN05130205 1735 - 0400 ERIN BRANCH Houston 14.4 Escherichia coli H High Density Municipal Area Erin area impacts. Category 5.

(One or more uses impaired.)

TN05130205 1735 - 1000 WELLS CREEK Houston 9.9 Escherichia coli NA Undetermined Source Erin area impacts. Category 4a. EPA has approved a pathogen TMDL that addresses the known pollutant.

43 Red River Watershed This basin contains the following USGS Hydrologic Unit Code: 05130206 Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN05130206 002 - 0100 DUNBAR CAVE CREEK Montgomery 2.7 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Discharges from MS4 area Land Development Stream is Category 5. (One or more uses impaired.)

TN05130206 002 - 0200 ELK FORK CREEK Robertson 3.9 Alteration of stream-side or littoral vegetation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN05130206 002 - 0300 SPRING CREEK Robertson 12.25 Escherichia coli H Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN05130206 002 - 0400 BUZZARD CREEK Robertson 11.0 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130206 002 - 0700 SEVEN SPRINGS Montgomery 1.1 Loss of biological integrity due to siltation M Escherichia coli NA Discharges from MS4 area Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN05130206 002 - 1000 RED RIVER Montgomery 2.4 Loss of biological integrity due to siltation M Escherichia coli NA Other Habitat Alterations M Nutrients L Nonirrigated Crop Production Collection System Failure Land Development Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants in this stream.

TN05130206 002 - 2000 RED RIVER Montgomery 22.9 Nitrates L Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN05130206 002 - 3000 RED RIVER Montgomery Robertson 17.5 Nitrates L Nonirrigated Crop Production Impairment is to domestic water supply use. Category 5.

TN05130206 002 - 4000 RED RIVER Robertson 4.5 Nitrates L Nonirrigated Crop Production Impairment is to domestic water supply use. Category 5.

TN05130206 002 - 5000 RED RIVER Robertson 3.3 Alteration to stream-side or littoral vegetation M Physical Substrate Habitat Alterations M Nitrates L Nonirrigated Crop Production Pasture Grazing Nitrate impairment is to domestic water supply use.

Stream is Category 5. (One or more uses impaired.)

TN05130206 003 - 0100 CHAMBERS SPRING BRANCH Robertson 4.3 Alteration to stream-side or littoral vegetation M Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5 (one or more uses impaired).

TN05130206 003 - 0300 PEPPERS BRANCH Robertson 4.2 Loss of biological integrity due to siltation M Pasture Grazing Segment contains a large wetland area. Category 5.

TN05130206 003 - 1100 WARTRACE CREEK Robertson 0.72 Temperature Alterations L Flow Alterations NA Upstream Impoundment Category 5, but flow alteration is 4c (impact not caused by a pollutant).

44 Final Version 2010 303(d) LIST (Red River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE (Pollutant)

Pollutant Source COMMENTS TN05130206 003 - 1200 CARR CREEK Robertson 2.9 Escherichia coli NA Collection System Failure Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN05130206 003 - 1220 UNNAMED TRIB TO CARR CREEK Robertson 1.6 Nutrients M Thermal Modifications L Escherichia coli NA Municipal Point Source Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130206 003 - 1250 CARR CREEK Robertson 7.8 Nitrate+Nitrite L Total Phosphorus L Collection System Failure Stream is Category 5. (One or more uses impaired.)

TN05130206 003 - 1255 CARR CREEK Robertson 11.3 Nitrate+Nitrite L Total Phosphorus L Escherichia coli NA Collection System Failure Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130206 003 - 1450 MILLERS CREEK Robertson 3.5 Loss of biological integrity due to siltation M Land Development Stream is Category 5. (One or more uses impaired.)

TN05130206 003 - 3000 SULPHUR FORK Robertson 1.9 Nitrate+Nitrite L Total Phosphorus L Loss of biological integrity due to siltation M Major Municipal Point Source Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN05130206 019 - 0321 FREY BRANCH Robertson 7.2 Total Phosphorus L Loss of biological integrity due to siltation L Escherichia coli NA Minor Municipal Point Source Unrestricted Cattle Access Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130206 019 - 0600 SMITH BRANCH Robertson 4.1 Loss of biological integrity due to siltation M Alteration of stream-side or littoral vegetation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN05130206 019 - 1000 SOUTH FORK RED RIVER Robertson 12.9 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN05130206 024 - 0150 SUMMERS BRANCH Robertson Sumner 12.6 Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli NA Municipal Point Source Urbanized High Density Area Impacts include Portland STP.

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN05130206 024 - 0200 BUNTIN BRANCH Robertson Sumner 7.6 Loss of biological integrity due to siltation M Alteration of stream-side or littoral vegetation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN05130206 024 - 0600 SOMERVILLE BRANCH Robertson Sumner 4.3 Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

45 Final Version 2010 303(d) LIST (Red River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE (Pollutant)

Pollutant Source COMMENTS TN05130206 034 - 0100 FLETCHERS FORK Montgomery 25.3 Other Anthropogenic Habitat Alterations M NPS Pollution from Military Bases Stream is Category 5. (One or more uses impaired.)

TN05130206 034 - 0110 RACCOON BRANCH Montgomery 7.7 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Land Development Hydromodification Stream is Category 5. (One or more uses impaired.)

TN05130206 034 - 0300 NOAHS SPRING BRANCH Montgomery 2.8 Unknown Toxicity L Undetermined Source Source in Other State Stream is Category 5. (One or more uses impaired.)

TN05130206 034 - 1000 LITTLE WEST FORK Montgomery 9.9 Total Phosphorus L Loss of biological integrity due to siltation M Low Dissolved Oxygen L Major Municipal Point Source NPS Pollution from Military Bases Stream is Category 5. (One or more uses impaired.)

TN05130206 039 - 0150 SPRING CREEK Montgomery 22.5 Loss of biological integrity due to siltation M Total Phosphorus L Nitrate+Nitrite L Alteration of stream-side or littoral vegetation M Nonirrigated Crop Production Sources Outside State Stream is Category 5. (One or more uses impaired.)

TN05130206 039 - 1000 WEST FORK RED RIVER Montgomery 10.2 Loss of biological integrity due to siltation M Nitrate+Nitrite L Total Phosphorus L Other Anthropogenic Habitat Alterations M Land Development Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

North Fork Holston River This basin contains the following USGS Hydrologic Unit Codes: 06010101 (North Fork Holston)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010101 001 - 1000 NORTH FORK HOLSTON RIVER Hawkins Sullivan 6.1 Mercury L Industrial Point Source Source in Other State Contaminated Sediment Stream is Category 5.

Provides habitat for the federally listed mussel, five-rayed pigtoe (Fusconaia cuneolus) and fish, spotfin chub (Cyprinella monacha).

Advisory due to Hg historically discharged from Olin. EPA/VA should do TMDL.

46 South Fork Holston River This basin contains the following USGS Hydrologic Unit Codes: 06010102 (South Fork Holston).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010102 001 - 0100 MADD BRANCH Sullivan 2.7 Physical Substrate Habitat Alterations NA Discharges from MS4 area Channelization Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010102 001 - 2000 SOUTH FORK HOLSTON RIVER Sullivan 2.4 Low dissolved oxygen L Habitat loss due to stream flow alterations NA Thermal Modifications L Upstream Impoundment Category 5 (one or more uses impaired), but flow alteration is 4c (impact not caused by a pollutant).

TN06010102 003 - 0100 MILL CREEK Sullivan 6.6 Loss of biological integrity due to siltation M Pasture Grazing Urbanized High Density Area Stream is Category 5. (One or more uses impaired.)

TN06010102 003 - 0200 UNNAMED TRIB TO HORSE CREEK Sullivan Washington 3.8 Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010102 003 - 0410 LYNCH BRANCH Sullivan 3.06 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010102 003 - 0500 BEAR CREEK Sullivan 4.6 Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010102 003 - 0600 LITTLE HORSE CREEK Sullivan 6.46 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010102 003 - 1000 HORSE CREEK Sullivan 3.1 Alteration in stream-side or littoral vegetative cover M Escherichia coli H Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN06010102 003 - 3000 HORSE CREEK Sullivan 4.35 Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010102 006 - 1000 BOONE RESERVOIR Washington Sullivan 1968 ac PCBs NA Chlordane NA Contaminated Sediment Fishing advisory due to PCBs.

Category 4a. EPA approved a chlordane and PCB TMDL for the known pollutants.

TN06010102 006T - 0100 GAMMON CREEK Sullivan 3.8 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Nitrate+Nitrite L Low Dissolved Oxygen L Loss of biological integrity due to siltation NA Escherichia coli H Channelization Discharges from MS4 area Pasture Grazing Category 5. Impaired, but EPA approved a siltation/habitat alteration TMDL for some of the known pollutants.

47 Final Version 2010 303(d) LIST (South Fork Holston River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010102 006T - 0200 WAGNER CREEK Sullivan 5.5 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Discharges from MS4 area Category 4a. Impaired, but EPA approved siltation/habitat alteration and pathogen TMDLs for the known pollutants.

TN06010102 006T - 0300 CANDY CREEK Sullivan 3.2 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a siltation/habitat alteration and pathogen TMDLs for the known pollutants.

TN06010102 012 - 0100 UNNAMED TRIB TO SOUTH FORK HOLSTON RIVER Sullivan 2.0 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a siltation/habitat alteration and pathogen TMDLs for the known pollutants.

TN06010102 012 - 0200 PADDLE CREEK Sullivan 4.44 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutants.

TN06010102 012 - 0300 UNNAMED TRIB TO SOUTH FORK HOLSTON RIVER Sullivan 3.89 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a siltation/habitat alteration and pathogen TMDLs for the known pollutants.

TN06010102 012 - 0400 MORRELL CREEK Sullivan 4.89 Escherichia coli NA Pasture Grazing Category 4a. Approved pathogen TMDL for the known pollutant.

TN06010102 012 - 0700 DRY CREEK Sullivan 1.01 Escherichia coli NA Animal Feeding Operations (NPS)

Category 4a. EPA approved a pathogen TMDL for the known pollutants.

TN06010102 012 - 0800 INDIAN CREEK Sullivan 1.86 Alteration in stream-side or littoral vegetative cover NA Land Development Category 4a. EPA approved siltation/habitat alteration TMDL for the known pollutants.

TN06010102 012 - 0810 BIG ARM BRANCH Sullivan 5.77 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Land Development Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

48 Final Version 2010 303(d) LIST (South Fork Holston River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010102 012 - 0820 WOODS BRANCH Sullivan 3.05 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Discharges from MS4 Area Category 4a. Impaired, but EPA approved siltation/habitat alteration and pathogen TMDLs for the known pollutants.

TN06010102 012 - 0900 WEAVER BRANCH Sullivan 5.9 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010102 012 - 1000 SOUTH FORK HOLSTON RIVER Sullivan 12.9 Habitat loss due to stream flow alterations NA Thermal modifications L Upstream Impoundment Category 5, but flow alteration is 4C (impact not caused by a pollutant). River is impacted by discharges from South Holston Reservoir.

TN06010102 014 - 1000 SOUTH FORK HOLSTON RIVER Sullivan 4.4 Habitat loss due to stream flow alterations NA Thermal modifications L Upstream Impoundment Category 5, but flow alteration is 4C (impact not caused by a pollutant). River is impacted by discharges from South Holston Reservoir.

TN06010102 015 - 1000 SOUTH HOLSTON RESERVOIR Sullivan 7577 ac Mercury L Atmospheric Deposition Fishing advisory due to mercury. Category 5. EPA should take lead on TMDLs that involve atmospheric deposition.

TN06010102 0250 - 0900 WATERS BRANCH Johnson 1.82 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutants.

TN06010102 0231.0-0200 BIRCH BRANCH Johnson 4.39 Threatened by Low pH M Atmospheric Deposition/Natural Birch Branch is a high elevated tributary to Beaverdam Creek in Cherokee National Forest.

The biology is good, but the pH criterion was violated in multiple observations.

Atmospheric deposition is suspected, although natural rock formation cannot be ruled out. More monitoring is needed.

TN06010102 0231.0-2000 BEAVERDAM CREEK Johnson 6.5 Physical Substrate Habitat Alteration M Escherichia coli M Pasture Grazing Nonirrigated Crop Production Category 5. TMDLs needed.

49 Final Version 2010 303(d) LIST (South Fork Holston River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010102 0250 - 0700 CORUM BRANCH Johnson 1.96 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Category 5. TMDLs needed.

TN06010102 0250 - 0800 FLATWOOD BRANCH Johnson 2.07 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Category 5. TMDLs needed.

TN06010102 0250 - 1300 WATERS BRANCH Johnson 1.83 Loss of biological integrity due to siltation M Pasture Grazing Category 5. TMDLs needed.

TN06010102 0250 - 2000 LAUREL CREEK Johnson 3.8 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010102 041 - 0100 PAPERVILLE CREEK Sullivan 3.9 Loss of biological integrity due to siltation NA Land Development Category 4a. Impaired, but EPA approved a siltation TMDL for the known pollutant.

TN06010102 042 - 0200 BACK CREEK Sullivan 14.1 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Discharges from MS4 area Pasture Grazing Unrestricted Cattle Access Channelization Category 5. (One or more uses impaired.) EPA approved siltation/habitat alteration and pathogen TMDLs for some of the known pollutants.

TN06010102 042 - 0400 LITTLE CREEK Sullivan 0.3 Phosphorus L Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Discharges from MS4 area Channelization Sources Outside State Borders Category 4a. The stream is impaired for one or more uses.

Almost the entire watershed for Little Creek is in Virginia.

Virginia has an approved pathogen TMDL for this watershed.

TN06010102 042 - 0500 CEDAR CREEK Sullivan 11.8 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Other Anthropogenic Habitat Alterations NA Escherichia coli NA Discharges from MS4 Area Land Development Category 5. (One or more uses impaired.) However, EPA approved siltation/habitat alteration and pathogen TMDLs for some of the known pollutants.

TN06010102 042 - 1000 BEAVER CREEK Sullivan 11.1 Nitrate+Nitrite L Escherichia coli NA Discharges from MS4 Area Pasture Grazing Water contact advisory.

Category 5. EPA approved a pathogen TMDL for some of the known pollutants.

50 Final Version 2010 303(d) LIST (South Fork Holston River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010102 042 - 2000 BEAVER CREEK Sullivan 10.5 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Nitrate+Nitrite L Loss of biological integrity due to siltation NA Escherichia coli NA Channelization Pasture Grazing Discharges from MS4 Area Sources Outside State Borders Water contact advisory.

Pathogen levels higher at the stateline than further downstream. Category 5.

EPA approved siltation/habitat alteration and pathogen TMDLs for some of the known pollutants.

TN06010102 045 - 1000 FALL CREEK Sullivan 6.25 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Discharges from MS4 area Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010102 046 - 0100 TRANSBARGER BRANCH Sullivan 1.4 Other Anthropogenic Habitat Alterations NA Discharges from MS4 Area Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010102 046 - 0200 GRAVELLY CREEK Sullivan 4.9 Habitat loss due to alterations in stream-side or littoral vegetative cover M Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

TN06010102 046 - 0300 MILLER BRANCH Sullivan 2.15 Loss of biological integrity due to siltation M Escherichia coli H Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

TN06010102 046 - 0500 UNNAMED TRIB TO REEDY CREEK Sullivan 3.88 Loss of biological integrity due to siltation M Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

TN06010102 046 - 0600 CLARK BRANCH Sullivan 3.75 Loss of biological integrity due to siltation M Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

TN06010102 046 - 0800 TIMBERTREE BRANCH Sullivan 2.0 Loss of biological integrity due to siltation M Habitat loss due to alterations in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010102 046 - 1000 REEDY CREEK Sullivan 2.0 Loss of biological integrity due to siltation NA Other Anthropogenic Habitat Alterations NA Discharges from MS4 Area Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010102 047 - 0100 FORD CREEK Sullivan 5.5 Loss of biological integrity due to siltation M Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

TN06010102 0540 - 0800 PAINTER SPRING BRANCH Sullivan 1.02 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a siltation/habitat alteration and pathogen TMDL for the known pollutants.

51 Final Version 2010 303(d) LIST (South Fork Holston River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010102 237 - 0100 BOOHER CREEK Sullivan 7.2 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010102 237 - 1000 MUDDY CREEK Sullivan 12.3 Escherichia coli H Discharges from MS4 Area Category 5. TMDL needed.

TN06010102 702 - 1000 CEDAR CREEK Washington 10.1 Loss of biological integrity due to siltation M Habitat loss due to alterations in stream-side or littoral vegetative cover M Escherichia coli H Discharges from MS4 Area Pasture Grazing Stream is Category 5. (One or more uses impaired.)

Watauga River Basin This basin contains the following USGS Hydrologic Unit Codes: 06010103 (Watauga River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010103 001 - 1000 WATAUGA EMBAYMENT OF BOONE RESERVOIR Washington Sullivan 2432 ac PCBs NA Chlordane NA Contaminated Sediment Fishing advisory due to PCBs.

Category 4a. EPA approved a PCB/chlordane TMDL for the known pollutants.

TN06010103 006 - 0100 CARROLL CREEK Washington 4.3 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Alteration in stream-side or littoral vegetative cover M Escherichia coli H Discharges from MS4 area Pasture Grazing Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010103 006 - 1000 BOONES CREEK Washington 19.31 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Alteration in stream-side or littoral vegetative cover M Escherichia coli NA Discharges from MS4 area Pasture Grazing Land Development Stream is Category 5. EPA approved pathogen and siltation TMDLs that address some of the known pollutants.

TN06010103 008 - 0200 CAMPBELL BRANCH Carter 3.0 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Alteration in stream-side or littoral vegetative cover M Escherichia coli NA Discharges from MS4 area Stream is Category 5. EPA approved pathogen and siltation TMDLs that address some of the known pollutants.

52 Final Version 2010 303(d) LIST (Watauga River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010103 008 - 0400 DAVIS BRANCH Carter 5.9 Habitat loss due to stream flow alteration M Alteration in stream-side or littoral vegetative cover M Discharges from MS4 area Upstream Impoundment Stream is Category 5. (One or more uses impaired.)

TN06010103 008 - 0800 GAP BRANCH Carter 15.93 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli H Discharges from MS4 area Streambank Modification Septic Tanks Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010103 008 - 1000 WATAUGA RIVER Washington Carter 16.3 Undetermined Cause L Discharges from MS4 area Upstream Impoundment Stream is Category 5. (One or more uses impaired.)

TN06010103 008 - 2000 WATAUGA RIVER Carter 4.4 Temperature Alterations L Upstream Impoundment Stream is Category 5. (One or more uses impaired.)

TN06010103 009 - 1000 BRUSH CREEK Washington 20.3 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Other Anthropogenic Habitat Alterations M Escherichia coli H Discharges from MS4 area Stream is Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010103 011 - 1000 BUFFALO CREEK Carter 6.08 Nitrate+Nitrite L Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010103 013 - 0600 ROARING CREEK Carter 11.92 Iron H Upstream Impoundment Stream is Category 5. (One or more uses impaired.)

TN06010103 013 - 0811 GOUGE CREEK Carter 1.36 Loss of biological integrity due to siltation M Land Development Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010103 020 - 1000 WATAUGA LAKE Carter Johnson 6427 ac Mercury L Atmospheric Deposition Fishing advisory due to mercury. Category 5. EPA should take the lead on TMDLs that involve atmospheric deposition.

TN06010103 020T - 0200 SINK BRANCH Johnson 3.14 Nitrate+Nitrite M Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli NA Pasture Grazing Stream is Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010103 034 - 0300 TOWN CREEK Johnson 3.0 Habitat loss due to alteration in stream-side or littoral vegetative cover M Solids M Escherichia coli NA Land Development Municipal Point Source Discharge This stream is Category 5.

EPA has approved a pathogen TMDL that addresses some of the known pollutants.

53 Final Version 2010 303(d) LIST (Watauga River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010103 034 - 0311 CROOKED BRANCH Johnson 6.6 Habitat loss due to alteration in stream-side or littoral vegetative cover M Land Development Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010103 034 - 0320 FURNACE CREEK Johnson 15.51 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation NA Off-Road Vehicles Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010103 034 - 0400 FORGE CREEK Johnson 33.7 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Off-Road Vehicles Stream is Category 5. (One or more uses impaired.)

TN06010103 034 - 1000 ROAN CREEK Johnson 6.8 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL that addresses the known pollutants.

TN06010103 034 - 2000 ROAN CREEK Johnson 6.0 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Escherichia coli NA Municipal Point Source Discharge Pasture Grazing Category 5. EPA approved siltation and pathogen TMDLs that address some of the known pollutants.

TN06010103 046 - 0100 CATBIRD CREEK Washington 5.7 Loss of biological integrity due to siltation M Discharges from MS4 area Category 5. TMDL needed.

TN06010103 046 - 1000 SINKING CREEK Washington Carter 10.0 Escherichia coli NA Discharges from MS4 area Pasture Grazing Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010103 061 - 1000 REEDY CREEK Washington 10.7 Nitrates L Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation NA Escherichia coli H Discharges from MS4 area Pasture Grazing Channelization Stream is Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010103 635 - 0100 CASH HOLLOW CREEK Washington 3.48 Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli NA Discharges from MS4 area Water contact advisory.

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

54 Final Version 2010 303(d) LIST (Watauga River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010103 635 - 0200 COBB CREEK Washington 4.5 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation NA Discharges from MS4 area Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010103 635 - 1000 KNOB CREEK Washington 12.3 Alteration in stream-side or littoral vegetative cover M Nitrate+Nitrite L Loss of biological integrity due to siltation NA Escherichia coli NA Discharges from MS4 area Pasture Grazing Category 5. EPA approved a siltation and pathogen TMDL that addresses some of the known pollutants.

Holston River Basin This basin contains the following USGS Hydrologic Unit Codes: 06010104 (Holston River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010104 001 - 0100 LOVE CREEK Knox 9.7 Loss of biological integrity due to siltation M Other Anthropogenic Habitat Alterations M Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN06010104 001 - 0500 ROSEBERRY CREEK Knox 20.0 Escherichia coli NA Pasture Grazing Septic Tanks Category 5. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 001 - 0800 LOST CREEK Jefferson 26.8 Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Septic Tanks Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN06010104 001 - 0900 BEAVER CREEK Jefferson 21.0 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 001 - 1400 SWANPOND CREEK Knox 16.3 Loss of biological integrity due to siltation M Alteration in stream-side or littoral vegetative cover M Escherichia coli NA Channelization Discharges from MS4 Area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010104 001 - 2000 HOLSTON RIVER Grainger Jefferson 26.9 Low DO L Habitat loss due to stream flow alteration NA Upstream Impoundment Below Cherokee Reservoir.

Category 5, flow alteration is 4c (impact not caused by a pollutant). Habitat for federally listed pink mucket pearly mussel (Lampsilis abrupta).

55 Final Version 2010 303(d) LIST (Holston River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010104 004 - 2000 CHEROKEE RESERVOIR (UPPER)

Hawkins Hamblen 2,816 ac Mercury L Atmospheric Deposition Sources Outside the State Category 5. Assistance from EPA is needed for TMDLs which include atmospheric deposition.

TN06010104 004T - 0600 UNNAMED TRIB TO RED HOUSE BR.

EMBAYMENT Hawkins 1.5 Loss of biological integrity due to siltation M Sand/Gravel/Rock Quarry Category 5. (One or more uses impaired.)

TN06010104 004T - 0700 CLOUD CREEK Hawkins 8.2 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010104 004T - 0800 STONE MOUNTAIN BRANCH Hawkins 2.11 Loss of biological integrity due to siltation L Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN06010104 004T - 1100 STOCK CREEK Hawkins 4.2 Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010104 004T - 1250 CANEY CREEK Hawkins 16.8 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 004T - 1300 CROCKETT CREEK Hawkins 5.3 Loss of biological integrity due to siltation M Escherichia coli NA Discharges from MS4 area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010104 004T - 1510 THREE FORKS BRANCH Hawkins 1.96 Alteration in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010104 004T - 1610 WALKER BRANCH Hawkins 1.53 Loss of biological integrity due to siltation M Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010104 004T - 2200 TURKEY CREEK Hamblen 8.0 Loss of biological integrity due to siltation M Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli NA Collection System Failure Discharges from MS4 area Water contact advisory due to pathogens. Stream is Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010104 004T - 2500 MOSSY CREEK Jefferson 9.1 Zinc M Loss of biological integrity due to siltation M Escherichia coli NA Collection System Failure Discharges from MS4 area Subsurface Mining Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

56 Final Version 2010 303(d) LIST (Holston River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010104 009 - 1000 JOHN SEVIER DETENTION RESERVOIR Hawkins 1,024 ac Mercury L Sources Outside the State Atmospheric Deposition Category 5. Assistance from EPA is requested for TMDLs which include atmospheric deposition.

TN06010104 011 - 0100 SINKING CREEK Hawkins 2.7 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 011 - 0200 FORGEY CREEK Hawkins 3.6 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 011 - 0300 SURGOINSVILLE CREEK Hawkins 7.0 Escherichia coli NA Pasture Grazing Septic Tanks Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 011 - 0400 STONEY POINT CREEK Hawkins 13.1 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 011 - 0500 BRADLEY CREEK Hawkins 9.2 Escherichia coli NA Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 011 - 0510 RENFROE CREEK Hawkins 12.5 Escherichia coli NA Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 011 - 0700 HORD CREEK Hawkins 8.9 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 011 - 0800 ALEXANDER CREEK Hawkins 1.0 Biological integrity loss due to undetermined cause M Escherichia coli NA Discharges from MS4 area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010104 011 - 0850 ALEXANDER CREEK Hawkins 12.5 Escherichia coli NA Discharges from MS4 area Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 011 - 0900 SMITH CREEK Hawkins 4.6 Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli NA Discharges from MS4 area Pasture Grazing Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010104 011 - 1000 HOLSTON RIVER Hawkins 14.6 Mercury L Sources Outside the State Atmospheric Deposition Category 5. Assistance from EPA is requested for TMDLs which include atmospheric deposition.

57 Final Version 2010 303(d) LIST (Holston River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010104 011 - 1100 ARNOTT CREEK Hawkins 2.8 Thermal Modifications L Habitat loss due to stream flow alterations NA Major Industrial Point Source Stream is Category 5 overall (one or more uses impaired),

but flow alteration is 4c (impact not caused by a pollutant).

TN06010104 011 - 1600 HUNT CREEK Hawkins 7.7 Escherichia coli NA Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 011 - 2000 HOLSTON RIVER Hawkins 23.9 Mercury L Sources Outside the State Atmospheric Deposition Category 5. EPA assistance requested for TMDLs which include atmospheric deposition.

TN06010104 015 - 0300 STANLEY CREEK Hawkins 7.7 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 018 - 1000 RICHLAND CREEK Grainger 26.7 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 019 - 0100 LITTLE FLAT CREEK Knox 30.3 Escherichia coli NA Animal Feeding Operations (NPS)

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010104 019 - 2000 FLAT CREEK Union Knox 2.8 Escherichia coli NA Pasture Grazing Collection System Failure Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

Upper French Broad River Basin This basin contains the following USGS Hydrologic Unit Codes: 06010105 (Upper French Broad) and 06010106 (Pigeon River),

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010105 001 - 0100 CLEAR CREEK Cocke 28.0 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010105 001 - 0200 LONG CREEK Cocke 19.6 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010105 001 - 1000 FRENCH BROAD RIVER Cocke 4.08 Mercury L Atmospheric Deposition Fishing advisory due to mercury in largemouth bass.

Category 5.

58 Final Version 2010 303(d) LIST (Upper French Broad River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010105 003 - 1100 JOHNS CREEK Cocke 1.45 Escherichia coli NA Septic Tanks Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010105 003 - 1110 BAKER CREEK Cocke 4.4 Escherichia coli NA Septic Tanks Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010106 001 - 1100 ENGLISH CREEK Cocke 15.3 Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN06010106 001 - 2000 PIGEON RIVER-Cocke 16.0 Unknown Toxicity L Irrigated Crop Production Fishing advisory lifted in 2003.

Stream is Category 5. (One or more uses impaired.)

TN06010106 001 - 3000 PIGEON RIVER-Cocke 5.1 Flow Alteration NA Upstream Impoundment Fishing advisory lifted in 2003.

Category 4C. (Impairment not caused by pollutant.)

TN06010106 001 - 4000 PIGEON RIVER-Cocke 5.03 Color L Flow Alteration NA Major Industrial Point Source Source in Other State Upstream Impoundment Fishing advisory lifted in 2003.

Color from Blue Ridge Paper is still objectionable at times in this segment. NC or EPA should do TMDL. Category 5, but flow alteration is 4C.

(Impairment not caused by a pollutant.)

TN06010106 002 - 0100 UNNAMED TRIB TO SINKING CREEK Cocke 3.12 Flow Alterations NA Temperature Alterations L Upstream Impoundment Randomly selected for Impounded Streams Study.

Stream is Category 5, but flow alteration is 4C. (Impairment not caused by a pollutant.)

TN06010106 002 - 1000 SINKING CREEK Cocke 4.8 Loss of biological integrity due to siltation M Escherichia coli NA Municipal High Density Area Category 5. Category 4a.

EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010106 004 - 0500 ROCK CREEK Cocke 2.80 Low pH M Undetermined Source High elevation stream in Great Smoky Mountains National Park. Low pH source may be a combination of natural conditions (anakeesta) and atmospheric deposition.

Category 5. EPA should take the lead on atmospheric deposition TMDL.

59 Final Version 2010 303(d) LIST (Upper French Broad River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010106 004 - 0610 INADU CREEK Cocke 2.66 Low pH L Undetermined Source High elevation stream in Great Smoky Mountains National Park. Low pH source may be a combination of natural conditions (anakeesta) and atmospheric deposition.

Category 5. (One or more uses impaired.) EPA should take the lead on atmospheric deposition TMDL.

TN06010106 004 - 0810 OTTER CREEK Cocke 1.52 Low pH L Undetermined Source High elevation stream in Great Smoky Mountains National Park. Low pH source may be a combination of natural conditions (anakeesta) and atmospheric deposition.

Category 5. (One or more uses impaired.) EPA should take the lead on atmospheric deposition TMDL.

TN06010106 004 - 0820 COPPERHEAD BRANCH Cocke 1.13 Low pH L Undetermined Source High elevation stream in Great Smoky Mountains National Park. Low pH source may be a combination of natural conditions (anakeesta) and atmospheric deposition. 5.

(One or more uses impaired.)

EPA should take the lead on atmospheric deposition TMDL.

60 Lower French Broad River Basin This basin contains the following USGS Hydrologic Unit Codes: 06010107 (Lower French Broad)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010107 003 - 0120 HAPPY CREEK Sevier 17.2 Loss of biological integrity due to siltation M Alteration in stream-side or littoral vegetation M Pasture Grazing Category 5. One or more uses impaired.

TN06010107 003 - 1000 BOYDS CREEK Sevier 15.4 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA has approved a pathogen TMDL that addresses the known pollutants.

TN06010107 006 - 2000 FRENCH BROAD RIVER Sevier 4.9 Low Dissolved Oxygen L Thermal Modifications L Flow Alteration NA Upstream Impoundment Habitat for the federally listed fish, the snail darter (Percina tanasi). Segment impacted by Douglas Reservoir releases (low DO and flow alteration).

Category 5 (one or more uses impaired), but flow alteration is 4c (impact not caused by a pollutant). TVA has taken action to improve dissolved oxygen and flow conditions downstream of the dam.

TN06010107 007 - 0700 BUCK FORK Sevier 3.8 Low pH L Undetermined Source High elevation stream in Great Smoky Mountains National Park. Acidity source may be a combination of natural conditions (anakeesta) and Atmospheric deposition.

Category 5. (One or more uses impaired.) EPA should take the lead on TMDL.

TN06010107 007 - 0900 EAGLE ROCKS PRONG Sevier 6.4 Low pH L Atmospheric Deposition - Acidity High elevation stream in Great Smoky Mountains National Park. Documented loss of native trout populations.

Stream is Category 5. (One or more uses impaired.) EPA should take the lead on atmospheric deposition TMDL.

61 Final Version 2010 303(d) LIST (Lower French Broad River cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010107 007 - 1120 SHUTTS PRONG Sevier 4.79 Low pH L Undetermined Source High elevation stream in Great Smoky Mountains National Park. Acidity source is likely a combination of natural conditions (anakeesta) and atmospheric deposition.

Stream is Category 5. (One or more uses impaired.) EPA should take the lead on TMDL.

TN06010107 007 - 1130 LOWES CREEK Sevier 2.22 Low pH M Atmospheric Deposition - Acidity High elevation stream in Great Smoky Mountains National Park. Documented loss of native trout populations.

Stream is Category 5. (One or more uses impaired.) EPA should take the lead on atmospheric deposition TMDL.

TN06010107 007 - 1140 CANNON CREEK Sevier 3.72 Low pH M Atmospheric Deposition - Acidity High elevation stream in Great Smoky Mountains National Park. Documented loss of native trout populations.

Stream is Category 5. (One or more uses impaired.) EPA should take the lead on atmospheric deposition TMDL.

TN06010107 007 - 1600 MIDDLE CREEK Sevier 16.7 Escherichia coli M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010107 007 - 1650 MIDDLE CREEK Sevier 3.3 Chlorine L Escherichia coli M Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN06010107 007 - 2000 LITTLE PIGEON RIVER Sevier 2.4 Escherichia coli NA Septic Tanks Collection System Failure Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010107 010 - 0100 GNATTY BRANCH Sevier 1.8 Escherichia coli NA Septic Tanks Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

62 Final Version 2010 303(d) LIST (Lower French Broad River cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010107 010 - 0200 KING BRANCH Sevier 2.5 Escherichia coli NA Septic Tanks Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010107 010 - 0300 BEECH BRANCH Sevier 2.04 Escherichia coli NA Septic Tanks Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010107 010 - 0400 DUDLEY CREEK Sevier 5.7 Escherichia coli NA Discharges from MS4 area Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010107 010 - 0500 ROARING FORK Sevier 1.5 Escherichia coli NA Collection System Failure Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010107 010 - 0600 BASKINS CREEK Sevier 1.3 Escherichia coli NA Collection System Failure Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010107 010 - 1000 WEST PRONG LITTLE PIGEON RIVER Sevier 8.1 Escherichia coli NA Loss of biological integrity due to siltation NA Total Phosphorus L The trout stream portion of this segment is considered threatened by elevated water temperatures and low DO.

Septic Tanks Collection System Failure Land Development Channelization Municipal Point Source Discharges from MS4 Area Water contact advisory.

Development between Sevierville and Pigeon Forge adding silt to river. Category

5. EPA has approved siltation and pathogen TMDLs that address some of the known pollutants.

TN06010107 010 - 1100 ROAD PRONG Sevier 4.6 Low pH L Undetermined Source High elevation stream in Great Smoky Mountains National Park. Acidity source may be a combination of natural conditions (anakeesta) and atmospheric deposition.

Stream is Category 5. (One or more uses impaired.) EPA should take the lead on TMDL.

63 Final Version 2010 303(d) LIST (Lower French Broad River cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010107 010 - 1300 HOLY BRANCH Sevier 2.01 Escherichia coli NA Collection System Failure Water contact advisory.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010107 010 - 1800 MILL CREEK Sevier 5.9 Physical Substrate Habitat Alterations NA Escherichia coli NA Collection System Failure Discharges from MS4 area Channelization Category 4a. Impaired, but EPA approved pathogen and habitat alteration TMDLs for the known pollutants.

TN06010107 010 - 1900 WALDEN CREEK Sevier 2.6 Escherichia coli NA Septic Tanks Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010107 010 - 1910 COVE CREEK Sevier 8.5 Escherichia coli M Septic Tanks Pasture Grazing Stream randomly selected for the Wadeable Streams Study.

Stream is Category 5. One or more uses impaired.

TN06010107 010 - 1950 WALDEN CREEK Sevier 8.6 Loss of biological integrity due to siltation NA Alteration in stream-side or littoral vegetative cover NA Pasture Grazing Land Development Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010107 010 - 2000 WEST PRONG LITTLE PIGEON RIVER Sevier 5.7 Biological integrity loss due to undetermined cause M Escherichia coli NA Total Phosphorus L This section is a trout stream and is considered threatened by low dissolved oxygen and elevated water temperatures.

Septic Tanks Collection System Failure Discharges from MS4 area Municipal Point Sources Water contact advisory due to pathogens. Stream is Category 5. One or more uses impaired, but EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010107 010 - 3000 WEST PRONG LITTLE PIGEON RIVER Sevier 5.4 Total Phosphorus L Escherichia coli NA This section is a trout stream and is considered threatened by low dissolved oxygen and elevated water temperatures.

Municipal Point Sources Discharges from MS4 Area Septic Tanks Collection System Failure Water contact advisory.

Stream is Category 5. One or more uses impaired. EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN06010107 010 - 4000 WEST PRONG LITTLE PIGEON RIVER Sevier 1.3 Escherichia coli M Discharges from MS4 Area Gatlinburg section. Stream is Category 5. One or more uses impaired.

64 Final Version 2010 303(d) LIST (Lower French Broad River cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010107 029T - 0400 LEADVALE CREEK Jefferson 4.4 Escherichia coli M Urbanized High Density Area Water contact advisory.

Stream is Category 5. One or more uses impaired.

TN06010107 029T - 0600 CLAY CREEK Cocke 22.3 Escherichia coli M Pasture Grazing Water contact advisory.

Stream is Category 5. One or more uses impaired.

TN06010107 029T - 1100 CLEAR CREEK Jefferson 3.3 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010107 029T - 1150 CLEAR CREEK Jefferson Cocke 13.6 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010107 038 - 1000 DUMPLIN CREEK Jefferson Sevier 19.1 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli M Pasture Grazing Land Development Channelization Category 5. (One or more uses impaired.) EPA approved a siltation/habitat alteration TMDL for some of the known pollutants.

Nolichucky River This basin contains the following USGS Hydrologic Unit Codes: 06010108 (Nolichucky River)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 001 - 0100 FLAT CREEK Hamblen 4.9 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutants.

TN06010108 001 - 0110 ROBINSON CREEK Hamblen 3.4 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 001 - 1000 NOLICHUCKY RIVER Hamblen Cocke 4.0 Loss of biological integrity due to siltation NA Irrigated Crop Production Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 001 - 3000 NOLICHUCKY RIVER Greene Cocke 9.0 Loss of biological integrity due to siltation NA Pasture Grazing Source in Other State Category 4a. EPA approved a siltation TMDL for the known pollutant. Provides habitat for the federally listed snail darter (Percina tanasi).

65 Final Version 2010 303(d) LIST (Nolichucky River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 005 - 0310 PRIVET BRANCH Greene 1.4 Loss of biological integrity due to siltation NA Alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration pathogen TMDL for the known pollutant.

TN06010108 005 - 0500 GREGG BRANCH Greene 2.7 Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved siltation and pathogen TMDLs for the known pollutants.

TN06010108 005 - 0710 SHELTON BRANCH Greene 1.23 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Channelization Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 005 - 3000 NOLICHUCKY RIVER Greene 6.4 Loss of biological integrity due to siltation NA Pasture Grazing Source in Other State Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 007 - 0100 LITTLE MEADOW CREEK Greene Cocke 16.91 Escherichia coli NA Unrestricted Cattle Access Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010108 007 - 1000 MEADOW CREEK Greene Cocke 23.4 Escherichia coli NA Unrestricted Cattle Access Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010108 009 - 0300 CEDAR CREEK Greene 5.4 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 010 - 0200 HOLLEY CREEK Greene 8.5 Loss of biological integrity due to siltation NA Land Development Discharges from MS4 area Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 010 - 0300 COLLEGE CREEK Greene 9.3 Loss of biological integrity due to siltation NA Other Anthropogenic Habitat Alterations NA Alteration in stream-side or littoral vegetative cover NA Pasture Grazing Land Development Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 010 - 0400 MOON CREEK Greene 8.7 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Land Development Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 010 - 0500 PUDDING CREEK Greene 5.5 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Other Anthropogenic Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

66 Final Version 2010 303(d) LIST (Nolichucky River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 010 - 0600 RIPLEY CREEK Greene 8.5 Escherichia coli M Pasture Grazing Category 5. TMDLs needed.

TN06010108 010 - 0750 RHEATOWN CREEK Greene 6.7 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Land Development Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 010 - 0900 SNAPP BRANCH Washington 1.9 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 010 - 1000 NOLICHUCKY RIVER Greene 9.4 Loss of biological integrity due to siltation NA Pasture Grazing Source in Other State Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 010 - 1100 ASBURY CREEK Washington 2.33 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 010 - 1200 KNAVE BRANCH Washington 4.6 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 010 - 1300 KEPLINGER CREEK Washington 5.3 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 010 - 1400 LEBANON BRANCH Washington 1.9 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 010 - 1910 SPRING CREEK Unicoi 1.7 Other Anthropogenic Substrate Alterations NA Solids L Discharges from MS4 area Aquaculture (permitted)

Fish hatchery is source of solids. Category 5. EPA approved a habitat alteration TMDL for some of the known pollutants.

TN06010108 010 - 3000 NOLICHUCKY RIVER Greene Washington 22.6 Loss of biological integrity due to siltation NA Pasture Grazing Source in Other State Category 4a. EPA approved a siltation TMDL for the known pollutant.

67 Final Version 2010 303(d) LIST (Nolichucky River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 010 - 3800 WOLF BRANCH Greene 1.3 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 010 - 6000 NOLICHUCKY RIVER Unicoi 2.06 Loss of biological integrity due to siltation NA Source in Other State Category 4a. EPA approved a siltation TMDL for the known pollutant. Provides habitat for the federally listed Appalachian elktoe (Alasmidonta rayeneliana).

TN06010108 029 - 0900 TATE SPRINGS Unicoi 2.33 Suspended Solids M Aquaculture Fish hatchery is source of solids. Stream is Category 5.

(One or more uses impaired.)

TN06010108 030 - 0100 CEDAR CREEK Greene 3.3 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved a siltation/habitat alteration pathogen TMDL for the known pollutants.

TN06010108 030 - 0200 JOCKEY CREEK Greene 8.0 Nitrate+Nitrite NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved nutrient, siltation and pathogen TMDLs for the known pollutants.

TN06010108 030 - 0220 CARSON CREEK Greene Washington 17.9 Nitrate+Nitrite NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Unrestricted Cattle Access Category4a. EPA approved a nutrient, siltation, and pathogen TMDLs for the known pollutants.

TN06010108 030 - 0400 CLEAR FORK Washington 12 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010108 030 - 0410 BLACKLEY CREEK Washington 16 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010108 030 - 0420 UNNAMED TRIB TO CLEAR FORK Washington 6.9 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 030 - 0430 MUDDY FORK Washington 23.8 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010108 030 - 0431 LEESBURG BRANCH Washington 3.4 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

68 Final Version 2010 303(d) LIST (Nolichucky River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 030 - 1000 BIG LIMESTONE CREEK Greene Washington 3.1 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010108 030 - 2000 BIG LIMESTONE CREEK Washington 8.8 Total Phosphorus L Nitrate+Nitrite L Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 5. (One or more uses impaired.) EPA approved siltation and pathogen TMDLs for some of the known pollutants.

TN06010108 033 - 0100 BUFFALO CREEK Greene 3.0 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alteration NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 033 - 1000 PIGEON CREEK Greene 8.8 Escherichia coli NA Discharges from MS4 area Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010108 035 - 0200 POTTER CREEK Greene 15.3 Low Dissolved Oxygen NA Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved dissolved oxygen, siltation/habitat alteration and pathogen TMDLs for the known pollutants.

TN06010108 035 - 0400 MUD CREEK Greene 4.4 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010108 035 - 0700 LICK BRANCH Greene 1.2 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010108 035 - 0900 PUNCHEON CAMP CREEK Greene 11.5 Nitrates+Nitrites NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved nutrient, siltation, and pathogen TMDLs for the known pollutants.

TN06010108 035 - 1000 LICK CREEK Greene 3.9 Nitrates+Nitrites NA Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved nutrient, siltation/habitat alteration, and pathogen TMDLs for the known pollutants.

TN06010108 035 - 1110 BABB CREEK Greene 4.6 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010108 035 - 1400 GARDINER CREEK Greene 5.4 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

69 Final Version 2010 303(d) LIST (Nolichucky River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 035 - 1410 WATTENBARGER CREEK Greene 5.3 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010108 035 - 1800 PYBORN CREEK Greene 6.4 Loss of biological integrity due to siltation NA Alteration of stream-side or littoral vegetation NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved siltation/habitat alteration and pathogen TMDLs for the known pollutants.

TN06010108 035 - 1900 CLEAR CREEK Greene Washington 19.9 Loss of biological integrity due to siltation NA Escherichia coli H Pasture Grazing Unrestricted Cattle Access Randomly selected for EPAs National Wadeable Streams Study. Category 5. EPA approved a siltation TMDL for some of the known pollutants.

TN06010108 035 - 2000 LICK CREEK Greene 2.3 Low Dissolved Oxygen L Escherichia coli NA Pasture Grazing Category 5. EPA approved a pathogen TMDL for some of the known pollutants.

TN06010108 035 - 2300 HORSE FORK Greene 1.6 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010108 035 - 2320 DAVIS CREEK Greene 2.8 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutant.

TN06010108 035 - 2400 HOODLEY BRANCH Greene 5.3 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010108 035 - 2521 POSSUM CREEK Greene 7.5 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010108 035 - 2600 GRASSY CREEK Greene 12.6 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010108 035 - 2800 MINK CREEK Greene 9.1 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010108 035 - 2810 POND CREEK Greene 2.2 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

70 Final Version 2010 303(d) LIST (Nolichucky River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 035 - 3000 LICK CREEK Greene 7.4 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Pasture Grazing Category 5. EPA approved siltation/habitat alteration and pathogen TMDLs for some of the known pollutants.

TN06010108 035 - 3100 WOLF CREEK Greene 2.1 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 035 - 4000 LICK CREEK Greene 4.9 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutants.

TN06010108 035 - 5000, 6000 & 7000 LICK CREEK Greene 36.1 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Physical Substrate Habitat Alteration NA Escherichia coli NA Pasture Grazing Category 5. EPA approved a siltation/habitat alteration and pathogen TMDL for some of the known pollutants.

TN06010108 035 - 8000 LICK CREEK Greene 7.2 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010108 035 - 9000 LICK CREEK Greene 7.7 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 5. EPA approved siltation and pathogen TMDLs for some of the known pollutants.

TN06010108 042 - 0100 HALE BRANCH Hamblen 7.1 Alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

TN06010108 042 - 0600 MUD CREEK Hamblen Hawkins 8.2 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010108 042 - 0610 WHITEHORN CREEK Hamblen Hawkins 17.9 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 042 - 0612 COLDSPRING BRANCH Hawkins 1.1 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 042 - 1000 BENT CREEK Hamblen 13.7 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

71 Final Version 2010 303(d) LIST (Nolichucky River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 043 - 0200 CRIDER CREEK Jefferson 6.2 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 043 - 0300 SARTAIN CREEK Jefferson 4.4 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 043 - 0310 CARTER BRANCH Jefferson Hamblen 3.5 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 043 - 0400 CEDAR CREEK Hamblen Jefferson 7.5 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 043 - 1000 LONG CREEK Jefferson Hamblen 13.5 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010108 064 - 1000 &

2000 SINKING CREEK Greene 23.4 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010108 088 - 1000 HORSE CREEK Greene 14.28 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010108 102 - 0100 UNNAMED TRIB TO RICHLAND CREEK Greene 4.05 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 102 - 0200 SIMPSON CREEK Greene 1.87 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 102 - 0300 TIPTON CREEK Greene 1.60 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 102 - 0400 EAST FORK RICHLAND CREEK Greene 4.96 Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutant.

72 Final Version 2010 303(d) LIST (Nolichucky River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 102 - 2000 RICHLAND CREEK Greene 8.51 Nitrate+Nitrite NA Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Pasture Grazing Discharges from MS4 area Category 4a. EPA approved nutrient, siltation/habitat alteration and pathogen TMDLs for the known pollutants.

TN06010108 456 - 0200 DRY CREEK Greene 3.3 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Sand/Gravel/Rock Mining Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 510 - 0100 BROWN BRANCH Washington 8.3 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Land Development Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 510 - 0200 BACON BRANCH Washington 4.6 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 510 - 0300 FEIST BRANCH Washington 2.3 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 510 - 0400 HOMINY CREEK Washington 7.0 Nitrate+Nitrite NA Escherichia coli NA Agriculture Category 4a. EPA approved nutrient and pathogen TMDLs for the known pollutants.

TN06010108 510 - 0500 ONION CREEK Washington 4.0 Loss of biological integrity due to siltation NA Pasture Grazing Land Development Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 510 - 1000 LITTLE LIMESTONE CREEK Washington 8.0 Nitrate+Nitrite L Escherichia coli NA Pasture Grazing Category 5, but EPA approved a pathogen TMDL for some of the known pollutants.

TN06010108 510 - 2000 LITTLE LIMESTONE CREEK Washington 13.5 Nitrate+Nitrite L Total Phosphorus L Physical Substrate Habitat Alterations NA Ammonia L Escherichia coli NA Discharges from MS4 area Municipal Point Source Pasture Grazing Category 5. Category 4a.

EPA approved pathogen and habitat alteration TMDLs for some of the known pollutants.

TN06010108 536 - 0200 LITTLE CHEROKEE CREEK Washington 7.2 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Land Development Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 DCROCKET T - 1000 DAVY CROCKETT RESERVOIR Greene 383 ac Loss of biological integrity due to siltation NA Pasture Grazing Source in Other State Category 4a. EPA approved a siltation TMDL for the known pollutant.

73 Final Version 2010 303(d) LIST (Nolichucky River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010108 DCTRIBS-0100 MUTTON CREEK Greene 1.7 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010108 DCTRIBS -

0200 JOHNSON CREEK Greene 1.4.

Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 DCTRIBS -

0500 MUD CREEK Greene 21.4 Loss of biological integrity due to siltation NA Pasture Grazing Land Development Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010108 DCTRIBS -

0600 FLAG BRANCH Greene 5.8 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Channelization Category 4a. EPA approved a siltation/habitat alteration TMDL for the known pollutants.

Upper Tennessee River Basin This basin contains the following USGS Hydrologic Unit Codes: 06010201 (Watts Bar Res., Fort Loudoun Res., and Little River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010201 001 - 1000 WATTS BAR RESERVOIR Rhea Roane Meigs 34075 ac PCBs NA Contaminated sediments Fishing advisory due to PCBs.

Category 4a. EPA approved a PCB TMDL for the known pollutant.

TN06010201 001 - 2000 UPPER WATTS BAR RESERVOIR Sweetwater Creek to Fort Loudoun Dam.

Loudon 1971 ac Low DO L PCBs NA Upstream Impoundment Contaminated Sediment Fishing advisory due to PCBs.

Category 5. EPA approved a PCB TMDL for some of the known pollutants. Provides habitat for the federally listed fish, snail darter (Percina tanasi) and the following mussels: orange-foot pimpleback pearly mussel (Plethobasus cooperianus) and pink mucket pearly mussel (Lampsilis abrupta).

TN06010201 001T - 0100 WOLF CREEK Rhea 2.49 Alteration in stream-side or littoral vegetative cover NA Escherichia coli M Pasture Grazing Category 5. EPA approved habitat alteration TMDL for some of the known pollutants.

74 Final Version 2010 303(d) LIST (Upper Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010201 011 - 1000 PAINT ROCK CREEK Roane Loudon 12.2 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010201 013 - 0100 MUD CREEK McMinn Monroe 7.2 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010201 013 - 0200 GREASY BRANCH Loudon Monroe 7.3 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010201 013 - 1000 POND CREEK Loudon Monroe 13.57 Escherichia coli NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010201 013 - 2000 POND CREEK Loudon Monroe 4.18 Total Phosphorus L Nitrate+Nitrite L Escherichia coli NA Pasture Grazing Unrestricted Cattle Access Category 5. EPA approved a pathogen TMDL for some of the known pollutants.

TN06010201 015 - 0100 BACON CREEK Loudon Monroe 10.2 Nitrate+Nitrite L Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation M Physical Substrate Habitat Alteration M Escherichia coli NA Pasture Grazing Animal Feeding Operations (NPS)

Channelization Category 5. Impaired, but EPA approved pathogen and habitat alteration TMDLs for some of the known pollutants.

TN06010201 015 - 1000 SWEETWATER CREEK Loudon 7.75 Escherichia coli NA Pasture Grazing Animal Feeding Operation (NPS)

Category 5. EPA approved a pathogen TMDL for the known pollutant.

TN06010201 015 - 2000 SWEETWATER CREEK Loudon Monroe 10.13 Nitrate+Nitrite L Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli NA Municipal Point Source Discharge Channelization Pasture Grazing Land Development Animal Feeding Operation (NPS)

Category 5. EPA approved a pathogen TMDL for some of the known pollutants.

TN06010201 015 - 3000 SWEETWATER CREEK McMinn Monroe 8.68 Escherichia coli H Pasture Grazing Animal Feeding Operation (NPS)

This stream is Category 5.

TN06010201 020 - 1000 FORT LOUDOUN RESERVOIR Knox Loudon 14066 ac PCBs NA Contaminated Sediment Fishing advisory due to PCBs.

Category 4a. EPA approved a PCB TMDL for the known pollutant.

TN06010201 020 - 2000 FORT LOUDOUN RESERVOIR Knox 534 ac Mercury L PCBs NA Atmospheric Deposition Contaminated Sediment Fishing advisory due to mercury and PCBs. Category

5. EPA approved a PCB TMDL for some of the known pollutants.

75 Final Version 2010 303(d) LIST (Upper Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010201 026 - 0100 RODDY BRANCH Blount Knox 6.4 Alteration in stream-side or littoral vegetative cover NA Physical Substrate Habitat Alteration NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Channelization Stream is Category 4a. One or more uses impaired, but EPA has approved pathogen, siltation, and habitat alteration TMDLs that address the known pollutants.

TN06010201 026 - 0200 CANEY BRANCH Blount 1.43 Physical Substrate Habitat Alteration NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL for the known pollutants.

TN06010201 026 - 0300 HOLLYBROOK BRANCH Blount 2.78 Unionized Ammonia L Total Phosphorus L Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli H Pasture Grazing Category 5. EPA approved a siltation/habitat alteration TMDL for some of the known pollutants.

TN06010201 026 - 0400 PISTOL CREEK Blount 6.39 Loss of biological integrity due to siltation NA Escherichia coli NA Discharges from MS4 area Category 4a. EPA approved siltation and pathogen TMDLs for the known pollutants.

TN06010201 026 - 0410 SPRINGFIELD BRANCH Blount 5.48 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Discharges from MS4 area Category 5. EPA approved a pathogen TMDL for some of the known pollutants.

TN06010201 026 - 0420 BROWN CREEK Blount 22.07 Alteration in stream-side or littoral vegetative cover NA Nitrate+NItrite M Loss of biological integrity due to siltation NA Escherichia coli H Discharges from MS4 area Land Development This stream is Category 5.

One or more uses impaired, but EPA has approved siltation and habitat alteration TMDLs to address some of the known pollutants.

TN06010201 026 - 0421 DUNCAN BRANCH Blount 2.5 Flow Alteration NA Sand/Gravel/Rock Quarry Category 4c. Flow alteration is not caused by a pollutant.

TN06010201 026 - 0430 CULTON CREEK Blount 6.14 Loss of biological integrity due to siltation NA Escherichia coli NA Discharges from MS4 area Category 4a. EPA approved pathogen and siltation TMDLs for the known pollutants.

TN06010201 026 - 0431 LAUREL BANK BRANCH Blount 16.57 Loss of biological integrity due to siltation NA Discharges from MS4 area Category 4a. Approved siltation TMDL for the known pollutant.

TN06010201 026 - 0500 RUSSELL BRANCH Blount 3.0 PCBs L Loss of biological integrity due to siltation NA Contaminated Sediment RCRA Hazardous Waste Discharges from MS4 area Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010201 026 - 1000 LITTLE RIVER Blount 7.1 PCBs NA Contaminated Sediment Fishing advisory. Category 4a. Approved PCB TMDL addresses known pollutants.

76 Final Version 2010 303(d) LIST (Upper Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010201 026 - 2000 LITTLE RIVER Blount This 17.63 mile section of the Little River has been identified as threatened due to a documented decline in diversity at biological stations at miles 7.6 and 9.6.

The specific stressor is undetermined.

TMDL priority: Low.

Category 5. Provides habitat for the federally listed snail darter (Percina tanasi) and duskytail darter (Etheostoma percnurum), plus fine-rayed pigtoe (Fusconaia cuneolus).

TN06010201 027 - 0300 ROCKY BRANCH Blount 4.04 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli H Pasture Grazing Stream is Category 5.

Impaired, but EPA has approved siltation and habitat alteration TMDLs that address some of the known pollutants.

TN06010201 027 - 0400 PEPPERMINT BRANCH Blount 2.7 Loss of biological integrity due to siltation NA Escherichia coli H Discharges from MS4 area Pasture Grazing Category 5. EPA approved a siltation TMDL for some of the known pollutants.

TN06010201 028 - 0100 SPICEWOOD BRANCH Blount 2.23 Loss of biological integrity due to siltation NA Streambank Modifications Category 4a. EPA approved a siltation TMDL for the known pollutant.

TN06010201 028 - 0300 SOUTH FORK CROOKED CREEK Blount 8.21 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. Impaired, but EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010201 028 - 0500 FLAG BRANCH Blount 7.8 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli H Pasture Grazing Discharges from MS4 area Category 5. Impaired, but EPA approved a siltation/habitat alteration TMDL for some of the known pollutants.

TN06010201 028 - 1000 CROOKED CREEK Blount 13.91 Escherichia coli NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010201 031 - 1000 HESSE CREEK Blount 4.5 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010201 032 - 0510 GOSHEN PRONG Sevier 6.66 Low pH L Undetermined Source High elevation in Great Smoky Mountains National Park. Low pH due to a combination of natural conditions (anakeesta) and atmospheric deposition.

Category 5. EPA should take the lead on atmospheric deposition TMDL.

77 Final Version 2010 303(d) LIST (Upper Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010201 032 - 0530 UNNAMED TRIB. TO FISH CAMP PRONG Sevier 1.34 Low pH L Undetermined Source High elevation stream in Great Smoky Mountains National Park. Low pH source may be a combination of natural conditions (anakeesta) and atmospheric deposition.

Category 5. EPA should take the lead on atmospheric deposition TMDL.

TN06010201 032 - 0700 DRY BRANCH Blount 3.31 Escherichia coli NA Undetermined Source Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010201 032 - 0800 SHORT CREEK Blount 10.7 Nitrate+Nitrite M Undetermined Source Category 5. TMDLs needed.

TN06010201 032 - 0820 TIPTON BRANCH Blount 2.5 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Upstream Impoundments Category 4a. Impaired, but EPA approved a siltation/habitat alteration TMDL for the known pollutants.

TN06010201 033-0100 LITTLE ELLEJOY CREEK Blount 14.7 Nitrate+Nitrite L Escherichia coli NA Pasture Grazing Animal Feeding Operation Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010201 033 - 0200 PITNER CREEK Blount 13.5 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010201 033 - 1000 ELLEJOY CREEK Blount 14.78 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses known pollutant.

TN06010201 033 - 2000 ELLEJOY CREEK Blount 5.37 Nitrate+NItrite L Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 5. EPA approved siltation and pathogen TMDLs that address some of the known pollutants.

TN06010201 034 - 0200 WILDWOOD BRANCH Blount 6.26 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA has approved pathogen and habitat alteration TMDLs that address known pollutants.

TN06010201 034 - 1000 NAILS CREEK Blount Sevier 24.5 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

78 Final Version 2010 303(d) LIST (Upper Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010201 037 - 1000 LITTLE TURKEY CREEK Knox 14.0 Loss of biological integrity due to siltation NA Discharges from MS4 area Category 4a. EPA has approved a siltation TMDL that addresses the known pollutant.

TN06010201 038 - 1000 TOWN CREEK Loudon 12.9 Loss of biological integrity due to siltation NA Escherichia coli H Discharges from MS4 area Category 5. EPA approved a siltation TMDL for some of the known pollutants.

TN06010201 040 -0600 BLACK CREEK Roane 16.7 Polycyclic Aromatic Hydrocarbons (PAHs) L Nutrients L Physical Substrate Habitat Alterations M Municipal Point Source Discharges RCRA Hazardous Waste Channelization CERCLA site discharging PAHs. Category 5.

TN06010201 064 - 1000 STAMP CREEK Roane 13.4 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN06010201 065 - 1000 STEEKEE CREEK Loudon 11.0 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010201 066 - 0100 CASTEEL BRANCH Knox 0.95 Loss of biological integrity due to siltation NA Pasture Grazing Discharges from MS4 area Category 4a. Impaired, but EPA approved a siltation TMDL for the known pollutant.

TN06010201 066 - 0200 TWIN BRANCH Knox 1.87 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Discharges from MS4 area Category 4a. Impaired, but EPA approved siltation and habitat alteration TMDLs that address the known pollutants.

TN06010201 066 - 0400 GRANDVIEW BRANCH Knox 1.7 Escherichia coli NA Discharges from MS4 area Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010201 066 - 0500 McCALL BRANCH Knox 1.73 Loss of biological integrity due to siltation NA Discharges from MS4 area Streambank Modification Category 4a. Impaired, but EPA approved a siltation TMDL for the known pollutant.

TN06010201 066 - 0600 HIGH BLUFF BRANCH Knox 1.25 Escherichia coli NA Discharges from MS4 area Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010201 066 - 1000 STOCK CREEK Knox 3.77 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010201 066 - 1200 GUN HOLLOW BRANCH Knox 1.36 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL for the known pollutant.

TN06010201 066 - 2000 STOCK CREEK Knox 1.98 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

79 Final Version 2010 303(d) LIST (Upper Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010201 067 - 0100 EAST FORK THIRD CREEK Knox 2.78 Loss of biological integrity due to siltation NA Other Anthropogenic Habitat Alterations NA Escherichia coli NA Discharges from MS4 area Urbanized High Density Area Land Development Collection System Failure Category 4a. EPA approved siltation, pathogen, and habitat alteration TMDLs that address the known pollutants.

TN06010201 067 - 1000 THIRD CREEK Knox 17.86 Nitrates L Loss of biological integrity due to siltation NA Other Anthropogenic Habitat Alterations NA Escherichia coli NA Discharges from MS4 area Urbanized High Density Area Land Development Collection System Failure Water contact advisory due to pathogens. Category 5. EPA has approved siltation, pathogen, and habitat alteration TMDLs that address some of the known pollutants.

TN06010201 080 - 0100 WHITES CREEK Knox 10.2 Other Anthropogenic Habitat Alterations NA Escherichia coli H Discharges from MS4 area Streambank Modification Category 5. EPA approved a habitat alteration TMDL that addresses some of the known pollutants.

TN06010201 080 - 1000 FIRST CREEK Knox 16.1 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Other Anthropogenic Habitat Alterations NA Escherichia coli NA Discharges from MS4 area Urbanized High Density Area Collection System Failure Water contact advisory.

Category 5, impaired, but EPA has approved siltation, pathogen, and habitat alteration TMDLs that address some of the known pollutants.

TN06010201 083 - 1000 FLOYD CREEK Loudon Blount 7.7 Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved siltation and pathogen TMDLs for the known pollutants.

TN06010201 087 - 1000 HINES CREEK Loudon Roane 20.3 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA approved a pathogen TMDL for the known pollutant.

TN06010201 097-1000 SECOND CREEK Knox 12.8 Other Anthropogenic Habitat Alterations NA Nitrate+Nitrite L Loss of biological integrity due to siltation NA Escherichia coli NA Discharges from MS4 area Urbanized High Density Area Collection System Failure Water contact advisory.

Category 5. Impaired, but EPA approved siltation, pathogen, and habitat alteration TMDLs that address some of the known pollutants.

TN06010201 1015 - 1000 CLOYD CREEK Loudon 11.3 Escherichia coli NA Pasture Grazing Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL that addresses pathogens.

TN06010201 1149 - 1000 POLECAT CREEK Loudon 13.1 Nitrate+Nitrite L Loss of biological integrity due to siltation M Escherichia coli M Pasture Grazing Category 5. TMDLs needed.

TN06010201 1330 - 1000 SINKING CREEK Knox 4.1 Escherichia coli M Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

80 Final Version 2010 303(d) LIST (Upper Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010201 1334 - 0100 TEN MILE CREEK (formerly called Sinking Creek)

Knox 12.74 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli H Discharges from MS4 area This stream is Category 4a.

Impaired, but EPA has approved siltation and habitat alteration TMDLs that address the known pollutants.

TN06010201 340 - 1000 TURKEY CREEK Knox 15.8 Loss of biological integrity due to siltation NA Escherichia coli M Discharges from MS4 area Category 5. Impaired, but EPA has approved a siltation TMDL that addresses some of the known pollutants.

TN06010201 620 - 1000 CARDIFF CREEK Roane 3.8 Chrome, hexavalent L pH L CERCLA site Hexavalent chrome levels exceed acute criteria in this stream. This stream is Category 5. TMDL needed.

TN06010201 621 - 1000 CANEY CREEK Roane 18.2 Physical Substrate Habitat Alteration M Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Collection System Failure Category 5. Impaired, but EPA has approved siltation and pathogen TMDLs that address some of the known pollutants.

TN06010201 697 - 1000 FOURTH CREEK Knox 14.9 Physical Substrate Habitat Alterations NA Escherichia coli NA Discharges from MS4 area Channelization Category 4a. EPA approved pathogen and habitat alteration TMDLs that address the known pollutants.

TN06010201 719 - 1000 WILLIAMS CREEK Knox 2.8 Other Anthropogenic Habitat Alterations NA Escherichia coli NA Discharges from MS4 area Collection System Failure Category 4a. EPA approved pathogen and habitat alteration TMDLs that address the known pollutants.

TN06010201 721 - 1000 BAKER CREEK Knox 3.3 Nitrate+Nitrite L Other Anthropogenic Habitat Alterations NA Escherichia coli NA Discharges from MS4 area Collection System Failure Category 5. EPA approved pathogen and habitat alteration TMDLs that address some of the known pollutants.

TN06010201 723 - 1000 GOOSE CREEK Knox 4.9 Loss of biological integrity due to siltation NA Other Anthropogenic Habitat Alterations NA PCBs L Escherichia coli NA Collection System Failure Discharges from MS4 area RCRA Hazardous Waste Water contact advisory due to pathogens. Witherspoon Superfund site. Category 5.

EPA has approved siltation, pathogen, and habitat alteration TMDLs that address some of the known pollutants.

TN06010201 983 - 1000 POLECAT CREEK Blount 1.85 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Land Development Channelization This stream is Category 4a.

Impaired, but EPA has approved siltation and habitat alteration TMDLs that address the known pollutants.

81 Little Tennessee River Basin This basin contains the following USGS Hydrologic Unit Codes: 06010204 (Little Tennessee River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010204 001 - 1000 TELLICO RESERVOIR Loudon Monroe 16500 ac PCBs L Mercury L Contaminated Sediment Atmospheric Deposition Fishing advisory due to PCBs and mercury. The Tellico River was once habitat for the federally listed snail darter (Percina tanasi). Category 5.

EPA should take the lead on TMDLs that involve atmospheric deposition.

TN06010204 002 - 1000 FORK CREEK Loudon Monroe 19.3 Nitrate L Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 5. EPA has approved pathogen and siltation TMDLs that address some of the known pollutants.

TN06010204 004 - 0200 CRAIGHEAD CREEK Monroe 8.5 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4A. EPA approved siltation and habitat alteration TMDL that addresses the known pollutants.

TN06010204 004 - 1000 BAT CREEK Monroe 19.1 Escherichia coli NA Collection System Failure Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010204 020 - 1000 LITTLE TENNESSEE RIVER Monroe Blount 1.1 Habitat loss due to stream flow alteration NA Upstream Impoundment Flow is diverted around this section of the river below Calderwood Reservoir.

Category 4c. The impact is not caused by a pollutant.

TN06010204 042 - 0100 CENTENARY CREEK Blount 3.25 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4A. EPA approved siltation/habitat alteration TMDL that addresses the known pollutants.

TN06010204 042 - 0311 UNNAMED TRIBUTARY TO BIG SPRINGS BRANCH Blount 0.2 Temperature Alterations L Upstream Impoundment Category 5. The stream is impaired for one or more uses.

TN06010204 043 - 0300 LITTLE BAKER CREEK Blount 6.1 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4A. EPA approved a siltation/habitat alteration TMDL that addresses the known pollutants.

TN06010204 043 - 1000 BAKER CREEK Blount Loudon 18.22 Alteration in stream-side or littoral vegetative cover NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen and habitat alteration TMDLs that address some of the known pollutants.

TN06010204 044 - 0100 CANE CREEK Monroe 29.3 Escherichia coli H Undetermined Source Stream is Category 5. (One or more uses impaired.)

82 Final Version 2010 303(d) LIST (Little Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010204 045 - 0100 NORTH FORK NOTCHY CREEK Monroe 12.8 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4A. EPA approved siltation/habitat alteration TMDL that addresses the known pollutants.

TN06010204 045 - 1000 NOTCHY CREEK Monroe 11.2 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen and siltation/habitat alteration TMDLs that address the known pollutants.

TN06010204 056 - 0150 LAUREL CREEK Monroe 0.47 Habitat loss due to stream flow alteration NA Upstream Impoundment Category 4c. The impact is not caused by a pollutant.

TN06010204 056 - 1000 BIG CREEK Monroe 14.65 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010204 065 - 1000 ISLAND CREEK Monroe 10.0 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

Upper Clinch River This basin contains the following USGS Hydrologic Unit Codes: 06010205 (Upper Clinch River).

Waterbody ID Impacted Waterbody County Miles Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010205 001 - 1000 NORRIS RESERVOIR (Clinch River portion only)

Campbell Union 23,198 ac Mercury L Atmospheric Deposition Category 5. (One or more uses impaired.) Assistance from EPA is requested for TMDLs which include atmospheric deposition.

TN06010205 001T - 0200 CUCKLE CREEK Campbell 6.89 Loss of biological integrity due to siltation M Pasture Grazing Sand/Gravel/Rock Quarry Stream is Category 5. (One or more uses impaired.)

TN06010205 013 - 0500 GREASY ROCK CREEK Hancock 5.7 Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli NA Pasture Grazing Land Development Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010205 013 - 0620 EAST FORK PAINTHER CREEK Hancock 5.5 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010205 014 - 0400 FLAT GAP CREEK Hancock Hawkins 5.5 Biological integrity loss due to undetermined cause L Undetermined Source Stream is Category 5. (One or more uses impaired.)

83 Final Version 2010 303(d) LIST (Clinch River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010205 016 - 1000 CLINCH RIVER Hancock 16.88 Threatened by loss of native mussel species.

Threatened status.

TMDL priority: High Tennessee concerned about loss of mussel species from a stream that is one of the most important repositories for listed mussel species. EPA assistance needed to identify pollutants and control strategies.

TN06010205 064 - 0110 THOMPSON CREEK Campbell 5.14 Low pH NA Abandoned Mining Category 4a. EPA approved a pH TMDL that addresses the known pollutant.

TN06010205 064 - 1000 BIG CREEK Campbell 1.2 Biological integrity loss due to undetermined cause M Nitrate+Nitrite M Minor Municipal Point Source Stream is Category 5. (One or more uses impaired.)

TN06010205 064 - 2000 BIG CREEK Campbell 1.9 Nitrate+Nitrite M Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

Powell River This basin contains the following USGS Hydrologic Unit Codes: 06010206 (Powell River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010206 006 - 0150 OLD TOWN CREEK Claiborne 6.27 Loss of biological integrity due to siltation H Alteration in stream-side or littoral vegetative cover H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010206 006 - 0250 GAP CREEK Claiborne 6.76 Unknown Toxicity L Escherichia coli NA Municipal Point Source Septic Tanks Collection System Failure Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN06010206 006 - 0310 UNNAMED TRIB TO BLAIRS CREEK Claiborne 1.8 Loss of biological integrity due to siltation H Hwy/Road/Bridge Construction Stream is Category 5. (One or more uses impaired.)

TN06010206 007 - 0100 LITTLE CREEK Claiborne 9.4 Escherichia coli NA Septic Tanks Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010206 007 - 0700 MULBERRY CREEK Hancock 26.6 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010206 007 - 0710 LITTLE MULBERRY CREEK Claiborne Hancock 4.0 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

84 Final Version 2010 303(d) LIST (Upper Powell River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010206 007 - 2000 POWELL RIVER Hancock 12.88 Loss of Native Mussel Species H Source in Other State EPA should do the TMDL on this interstate stream.

Category 5. (One or more uses impaired.)

TN06010206 008 - 1000 RUSSELL CREEK Claiborne 8.1 Nitrate+Nitrite L Total Phosphorus L Escherichia coli NA Collection System Failure Pasture Grazing Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010206 008 - 2000 RUSSELL CREEK Claiborne 7.0 Nitrate+Nitrite L Loss of biological integrity due to siltation M Pasture Grazing Tazewell area impacts.

Stream is Category 5. (One or more uses impaired.)

TN06010206 026 - 0100 CAWOOD BRANCH Claiborne 5.2 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010206 026 - 0200 RUSSELL BRANCH Claiborne 3.5 Nitrate+Nitrite M Loss of biological integrity due to siltation H Physical Substrate Habitat Loss H Escherichia coli NA Pasture Grazing Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010206 026 - 1000 DAVIS CREEK Campbell Claiborne 8.0 Escherichia coli NA Confined Animal Feeding Operation (point and nonpoint)

Dairy operations. Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06010206 026 - 2000 DAVIS CREEK Claiborne 5.1 Nitrate+Nitrite L Loss of biological integrity due to siltation M Physical Substrate Habitat Alteration M Escherichia coli NA Pasture Grazing Dairy operations. Category 5.

EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010206 026 - 3000 DAVIS CREEK Claiborne 3.6 Nitrate+Nitrite L Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Dairy operations. Category 5.

EPA approved a pathogen TMDL that addresses some of the known pollutant.

TN06010206 026 - 4000 DAVIS CREEK Claiborne 2.6 Nitrate+Nitrite L Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Dairy operations. Category 5.

EPA approved a pathogen TMDL that addresses some of the known pollutant.

85 Lower Clinch River This basin contains the following USGS Hydrologic Unit Codes: 06010207 (Clinch River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010207 001 - 0100 POPLAR CREEK EMBAYMENT, WATTS BAR RESERVOIR Roane 141 ac PCBs L Mercury M Industrial Point Source Contaminated Sediments Fishing advisory due to PCBs and mercury. DOE impacts.

Stream is Category 5. EPA should produce TMDL for pollutants from DOE facilities.

TN06010207 001 - 1000 WATTS BAR RESERVOIR, CLINCH RIVER ARM Roane 2336 ac PCBs NA Chlordane NA Mercury L Industrial Point Source Contaminated Sediments Atmospheric Deposition Fishing advisory due to PCBs.

DOE Reservation impacts.

Mercury is metal of concern.

Category 5. EPA approved a PCB/chlordane TMDL that addresses some of the known pollutants. EPA should produce TMDL for pollutants from DOE facilities.

TN06010207 004 - 0100 GRABLE BRANCH Knox 1.3 Oil & Grease L Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations M Minor Industrial Point Source Channelization Industrial Permitted Runoff Discharges from MS4 area Truck stops near I-40.

Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010207 006 - 1000 MELTON HILL RESERVOIR Anderson Knox Loudon Roane 5690 ac PCBs L Chlordane L Contaminated Sediment Fishing advisory due to PCBs and chlordane. Category 5.

EPA should produce TMDL for pollutants from DOE facilities.

TN06010207 006T - 0700 MCCOY BRANCH Anderson 1.17 Arsenic L CERCLA NPL Sites Category 5. EPA should produce TMDL for pollutants from DOE facilities.

TN06010207 006T - 0900 SCARBORO CREEK Anderson 1.99 Escherichia coli H Municipal Urbanized Area Stream is Category 5. (One or more uses impaired.)

TN06010207 006T - 1100 ERNIES CREEK Anderson 4.1 Escherichia coli H Municipal Urbanized Area Stream is Category 5. (One or more uses impaired.)

TN06010207 011 - 0300 WILLOW FORK Knox 5.9 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Escherichia coli H Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN06010207 011 - 0400 COX CREEK Knox 4.5 Escherichia coli L Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN06010207 011 - 0500 HINES BRANCH Knox 3.2 Habitat loss due to other anthropogenic substrate alterations M Escherichia coli H Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

86 Final Version 2010 303(d) LIST (Clinch River cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE /TMDL Priority Pollutant Source COMMENTS TN06010207 011 - 0600 KNOB FORK Knox 8.1 Loss of biological integrity due to siltation NA Habitat loss due to other anthropogenic substrate M Alteration in stream-side or littoral vegetative cover M Escherichia coli M Discharges from MS4 area Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010207 011 - 0700 GRASSY CREEK Knox 8.2 Loss of biological integrity due to siltation NA Escherichia coli H Discharges from MS4 Area Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010207 011 - 0800 MEADOW CREEK Knox 4.96 Escherichia coli H Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

TN06010207 011 - 0900 PLUM CREEK Knox 5.3 Escherichia coli H Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

TN06010207 011 - 1000 BEAVER CREEK Knox 22.5 Phosphate L Nitrates L Escherichia coli NA Low Dissolved Oxygen L Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations M Major Municipal Point Source Pasture Grazing Discharges from MS4 Area Stream is Category 5.

Impaired, but EPA has approved siltation and pathogen TMDLs that address some of the known pollutants.

TN06010207 011 - 2000 BEAVER CREEK Knox 13.7 Escherichia coli NA Loss of biological integrity due to siltation NA Physical Substrate Habitat alterations M Pasture Grazing Discharges from MS4 Area Category 5. Impaired, but EPA has approved siltation and pathogen TMDLs that address some of the known pollutants.

TN06010207 011 - 3000 BEAVER CREEK Knox 7.5 Escherichia coli NA Loss of biological integrity due to siltation NA Physical Substrate Habitat alterations M Pasture Grazing Discharges from MS4 Area Category 5. EPA approved siltation and pathogen TMDLs that address some of the known pollutants.

TN06010207 014 - 0100 WILLIAMS BRANCH Knox 2.4 Loss of biological integrity due to siltation NA Industrial Permitted Runoff Category 4a. EPA approved a siltation TMDL that addresses the known pollutants.

TN06010207 014 - 1000 BULLRUN CREEK Knox Anderson 11.8 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alteration M Escherichia coli NA Discharges from MS4 Area Pasture Grazing Channelization Category 5. EPA approved a siltation and pathogen TMDLs that address some of the known pollutants.

TN06010207 014 - 3000 BULLRUN CREEK Union Grainger 11.4 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

87 Final Version 2010 303(d) LIST (Clinch River cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE /TMDL Priority Pollutant Source COMMENTS TN06010207 016 - 0200 BYRAMS CREEK Anderson Union 22.4 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010207 016 - 1000 HINDS CREEK Anderson 6.7 Loss of biological integrity due to siltation M Alteration in stream-side or littoral vegetative cover M Escherichia coli NA Pasture Grazing Stream is Category 5.

Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN06010207 019 - 2000 CLINCH RIVER Anderson 7.4 Thermal Modifications L Flow Alteration NA Upstream Impoundment Clinch River below Norris does not meet biocriteria due to rapid temperature and flow changes. Category 5, but flow alteration is 4c (impact not caused by a pollutant). TVA has taken action to improve dissolved oxygen and flow downstream of the dam.

TN06010207 020 - 0400 INDIAN CREEK Roane 6.8 Loss of biological integrity due to siltation M Alteration in stream-side or littoral vegetative cover M Channelization Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010207 020 - 1300 MITCHELL BRANCH Anderson 2.09 PCBs L Physical Substrate Habitat Alterations M CERCLA site Channelization Stream is Category 5. TMDLs for DOE sites should be done by EPA.

TN06010207 026 - 0600 BEAR CREEK Roane 10.87 Nitrates M Escherichia coli L CERCLA site Undetermined Source Stream is Category 5, uses impaired. TMDLs for DOE sites should be done by EPA.

TN06010207 026 - 1000 EAST FORK POPLAR CREEK Roane 9.7 PCBs L Mercury L Escherichia coli NA Loss of biological integrity due to siltation NA Nitrates L Phosphates L Industrial Point Source Municipal Point Source Contaminated Sediments Collection System Failure High Density Municipal Area Impacted by releases at DOEs Oak Ridge facilities (K-25, Y-12, ORNL). Fishing advisory due to mercury and PCBs.

Bacteria levels are also elevated due to sources in the Oak Ridge area. Category 5.

EPA approved siltation and pathogen TMDLs that address some of the known pollutants.

EPA should develop the TMDL for pollutants originating from DOE facilities.

88 Final Version 2010 303(d) LIST (Clinch River cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE /TMDL Priority Pollutant Source COMMENTS TN06010207 026 - 2000 EAST FORK POPLAR CREEK Anderson Roane 11.3 PCBs L Mercury L Escherichia coli NA Loss of biological integrity due to siltation NA Nutrients M Other Anthropogenic Habitat Alterations M Industrial Point Source Contaminated Sediments High Density Municipal Area Same as previous segment.

Category 5. EPA approved siltation and pathogen TMDLs that address some of the known pollutants. EPA should develop the TMDL for pollutants originating from DOE facilities.

TN06010207 028 - 1000 CANEY CREEK Roane 7.4 Loss of biological integrity due to siltation M Habitat loss due to alteration of stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06010207 029 - 1000 COAL CREEK Anderson 10.9 Biological integrity loss due to undetermined cause L Escherichia coli NA Minor Municipal Point Source Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06010207 029 - 2000 COAL CREEK Anderson 15.0 Escherichia coli M Septic Tanks Category 5. TMDLs needed.

TN06010207 247 - 0100 MELTON BRANCH Roane 2.0 Strontium NA CERCLA site Category 4B for strontium. A TMDL would not be helpful as the Cercla ROD is the enforceable control strategy here. However, any TMDLs for pollutants originating from DOE facilities should be developed by EPA.

TN06010207 247 - 1000 WHITEOAK CREEK Anderson 5.3 Cesium NA Strontium NA Biological integrity loss due to undetermined cause M CERCLA site Category 4B for strontium and cesium. A TMDL would not be helpful as the Cercla ROD is the enforceable control strategy here. Category 5 for unknown toxicity. TMDLs for pollutants originating from DOE facilities should be developed by EPA.

89 Emory River This basin contains the following USGS Hydrologic Unit Codes: 06010208 (Emory River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE TMDL Priority Pollutant Source COMMENTS TN06010208 001 - 1000 WATTS BAR RESERVOIR, EMORY RIVER ARM Roane 283.36 ac Mercury L PCBs NA Chlordane NA Industrial Point Source Atmospheric Deposition Contaminated Sediments Fishing advisory. Category 5.

EPA approved PCB and chlordane TMDLs that address some of the known pollutants.

TN06010208 001 - 2000 WATTS BAR RESERVOIR, EMORY RIVER ARM (Includes Swan Pond Creek embayment and unnamed embayment)

Roane 454.98 ac Arsenic NA Coal Ash Deposits NA Aluminum NA Mercury L PCBs NA Chlordane NA Other Spill Related Issues Industrial Point Source Atmospheric Deposition Contaminated Sediments Impacted by TVA Kingston ash spill of December, 2008. Ash dredging completed. Because a cleanup plan is in place and agreement has been reached by multiple agencies, it is unlikely that a TMDL would help with the coal ash deposits, or arsenic and aluminum, which are associated with the ash.

These pollutants are Category 4b. Fishing advisory is due to PCBs. Category 5. EPA approved PCB and chlordane TMDLs that address some of the known pollutants.

TN06010208 001 - 3000 WATTS BAR RESERVOIR, EMORY RIVER ARM Roane 362.64 ac Mercury L PCBs NA Chlordane NA Atmospheric Deposition Contaminated Sediments Fishing advisory. Category 5.

Approved chlordane and PCB TMDLs address some of the known pollutants.

TN06010208 001 - 4000 EMORY RIVER Roane Morgan 13.93 Mercury L Atmospheric Deposition Fishing advisory. Category 5.

EPA assistance requested for atmospheric mercury TMDLs.

TN06010208 004 - 0100 MUD CREEK Morgan 5.4 Alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. EPA approved a habitat alteration TMDL that addresses the known pollutant.

TN06010208 004 - 0200 FLAT FORK Morgan 3.7 Nitrate+Nitrite L Physical Substrate Habitat Alterations NA Loss of biological integrity due to siltation NA Pasture Grazing Channelization Category 5. EPA approved a siltation/habitat alteration TMDL that addresses some of the known pollutants.

TN06010208 004 - 0400 SUMMERS BRANCH Morgan 5.0 Loss of biological integrity due to siltation NA Abandoned Mining Category 5. EPA approved a siltation TMDL that addresses the known pollutants.

TN06010208 004 - 1000 CROOKED FORK Morgan 6.9 Nitrate+NItrite L Low Dissolved Oxygen L Municipal Point Source Discharge Pasture Grazing This stream is Category 5.

The stream is impaired for one or more uses.

90 Final Version 2010 303(d) LIST (Emory River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010208 004 - 2000 CROOKED FORK Morgan 16.7 Nitrate+NItrite L Low Dissolved Oxygen L Physical Substrate Habitat Alterations NA Loss of biological integrity due to siltation NA Permitted Small Flows Abandoned Mining Channelization Category 5. EPA approved a siltation/habitat alteration TMDL that addresses some of the known pollutants.

TN06010208 007 - 0210 SCANTLING BRANCH Cumberland 1.98 Low Dissolved Oxygen L Upstream Impoundment Category 5. The stream is impaired for one or more uses.

TN06010208 008 - 2000 CLEAR CREEK Morgan 1.41 Oil L Petroleum Activities Serious oil spill in this section of the Obed National Wild and Scenic River. Category 5.

Provides habitat for the listed Spotfin chub (Cyprinella monacha) and Tangerine darter (Percina aurantiaca).

TN06010208 013 - 0200 LITTLE OBED RIVER Cumberland 10.0 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Escherichia coli H Discharges from MS4 area Collection System Failure Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06010208 013 - 0400 DROWNING CREEK Cumberland 13.1 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Animal Feeding Operations (Nonpoint)

Category 4A. EPA approved a siltation/habitat alteration TMDL that addresses the known pollutants.

TN06010208 013 - 1000 OBED RIVER Cumberland 14.5 Nitrate+Nitrite L Total Phosphorus L Municipal Point Source Discharges from MS4 area Category 5. Federally-listed species have been documented downstream of this section, in the Wild and Scenic River section.

TN06010208 013 - 2000 OBED RIVER Cumberland 1.48 Habitat loss due to stream flow alterations NA Physical Substrate Habitat Alterations NA Discharges from MS4 area Upstream Impoundment Below Lake Holiday near Crossville. Category 4A, but flow alteration is 4c (impact not caused by a pollutant). EPA approved a habitat alteration TMDL that addresses the known pollutant.

TN06010208 015 - 0510 LONG BRANCH Cumberland 2.2 Loss of biological integrity due to siltation NA Sand/Gravel/Rock Mining Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

TN06010208 015 - 0800 BYRD CREEK Cumberland 38.6 Low Dissolved Oxygen L Upstream Impoundment Category 5 (impaired for one or more uses).

91 Final Version 2010 303(d) LIST (Emory River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06010208 015 - 0810 ONE MILE CREEK Cumberland 8.5 Loss of biological integrity due to siltation NA Land Development Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

TN06010208 015 - 0911 BAGWELL CREEK Cumberland 3.32 Flow Alteration NA Upstream Impoundment Category 4c. Impacts not from a pollutant TN06010208 015 - 0950 NORTH CREEK Cumberland 1.83 Flow Alteration NA Upstream Impoundment Category 4c. Impacts not from a pollutant TN06010208 015 - 1310 BLACK GUM BRANCH Cumberland 1.41 Flow Alteration NA Upstream Impoundment Category 4c. Impacts not from a pollutant TN06010208 020 - 0100 SMITH BRANCH Morgan 5.4 pH NA Abandoned Mines Category 4a. EPA approved a pH TMDL that addresses the known pollutant.

TN06010208 020 - 0400 GOLLIHER CREEK Morgan 5.6 Manganese M Iron M pH NA Abandoned Mines Category 5. EPA approved pH TMDL that addresses some of the known pollutants.

TN06010208 020 - 0500 FAGON MILL CREEK Morgan 2.6 Manganese M pH NA Abandoned Mines Category 5. EPA approved pH TMDL that addresses some of the known pollutants.

TN06010208 020 - 0600 LITTLE LAUREL CREEK Morgan 1.32 pH NA Abandoned Mines Category 4a. EPA approved a pH TMDL that addresses the known pollutant.

TN06010208 020 - 0700 LAUREL CREEK Morgan 3.7 pH NA Abandoned Mines Category 4a. EPA approved a pH TMDL that addresses the known pollutant.

TN06010208 020 - 3000 CRAB ORCHARD CREEK Morgan 7.9 Manganese M pH NA Abandoned Mines Category 5. EPA approved pH TMDL that addresses some of the known pollutants.

92 Lower Tennessee Basin This basin contains the following USGS Hydrologic Unit Codes: 06020001 (Nickajack/Chickamauga Reservoirs).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020001 001 - 1000 NICKAJACK RESERVOIR Marion Hamilton 10370.0 ac PCBs L Dioxins L Contaminated Sediment Precautionary fishing advisory for catfish. The federally listed fish, the snail darter (Percina tansi), has been documented.

Category 5.

TN06020001 001T - 0200 NORTH MARKET STREET BRANCH Hamilton 2.5 Physical Substrate Habitat Alterations M Escherichia coli NA Discharges from MS4 Area Collection System Failure In North Chattanooga.

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06020001 007 - 0100 FRIAR BRANCH Hamilton 18.94 Loss of biological integrity due to siltation NA Nutrients L Physical Substrate Habitat Loss NA Escherichia coli NA Land Development Discharges from MS4 area Collection System Failure Category 5. EPA approved siltation/habitat alteration and pathogen TMDLs that address some of the known pollutants.

TN06020001 007 - 0200 UNNAMED TRIB TO SOUTH CHICKAMAUGA CREEK Hamilton 1.1 Nutrients L Escherichia coli H Other Anthropogenic Habitat Losses NA Collection System Failure Discharges from MS4 area Channelization Category 5. EPA approved a habitat alteration TMDL that addresses some of the known pollutants.

TN06020001 007 - 0300 MACKEY BRANCH Hamilton 15.66 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Escherichia coli H Discharges from MS4 Area Collection System Failure Stream is Category 5. (One or more uses impaired.)

TN06020001 007 - 0510 SPRING CREEK Hamilton 9.6 Unknown Toxicity L Escherichia coli NA Discharges from MS4 area Collection System Failure Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06020001 007 - 1000 SOUTH CHICKAMAUGA CREEK Hamilton 17.6 Total Phosphorus L Physical Substrate Habitat Alterations NA Escherichia coli NA Loss of biological integrity due to siltation NA Land Development Discharges from MS4 area Channelization Sources Outside of State Collection System Failure Some pollutants from GA. The federally listed fish, the snail darter (Percina tansi), has been documented. Category

5. Approved pathogen and habitat alteration TMDLs address some pollutants.

TN06020001 029 - 0300 LEWIS BRANCH Hamilton 1.5 Alteration in stream-side or littoral vegetative cover NA Nitrate+Nitrite L Total Phosphorus L Low Dissolved Oxygen L Escherichia coli NA Confined Animal Feeding Operations (Nonpoint)

Pasture Grazing Category 5. EPA approved pathogen and habitat alteration TMDLs that address some of the known pollutants.

93 Final Version 2010 303(d) LIST (Lower Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020001 029 - 1000 LONG SAVANNAH CREEK Hamilton 15.0 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06020001 041 - 0320 BIVENS BRANCH McMinn 2.2 Low Dissolved Oxygen L Escherichia coli H Confined Animal Feeding Operations (Nonpoint)

Stream is Category 5. (One or more uses impaired.)

TN06020001 048 - 0450 LAUREL CREEK Rhea 0.63 Habitat loss due to stream flow alteration NA Low Dissolved Oxygen L Upstream Impoundment Stream randomly selected for Impounded Streams Study.

Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN06020001 049 - 1000 LITTLE RICHLAND CREEK Rhea 20.4 Alteration in stream-side or littoral vegetative cover M Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Urbanized High Density Area Channelization Stream is Category 5. (One or more uses impaired.)

TN06020001 057 - 0200 ROARING CREEK Rhea 5.3 Physical Substrate Habitat Alteration H Channelization In addition to channelization, some illegal rock harvesting in this stream. Category 5.

TN06020001 062 - 1000 POSSUM CREEK Hamilton Bledsoe 13.19 pH H Iron H Physical Substrate Habitat Alteration M Abandoned Mining Channelization In addition to channelization, some illegal rock harvesting in this stream. Category 5. (One or more uses impaired.)

TN06020001 067 - 0100 UNNAMED TRIB TO NORTH CHICKAMAUGA CREEK Hamilton 4.3 Loss of biological integrity due to siltation NA Other Anthropogenic Habitat Alterations NA Municipal High Density Area Land Development Near Grubb Road. Category 4a. EPA approved a siltation/habitat alteration TMDL that addresses the known pollutants.

TN06020001 067 - 0210 NINEMILE BRANCH Hamilton 4.0 Low Dissolved Oxygen L Physical Substrate Habitat Alterations NA Discharges from MS4 area Channelization Category 5. EPA approved a habitat alteration TMDL that addresses some of the known pollutants.

TN06020001 067 - 0500 BOSTON BRANCH Hamilton 1.12 Habitat loss due to stream flow alteration NA Upstream Impoundment Randomly selected for the Impounded Streams Study.

Category 4c. Impacts are not caused by a pollutant.

TN06020001 067 - 0600 STANDIFER CREEK Sequatchie 3.9 pH NA Abandoned Mining Category 4a. EPA approved a pH TMDL that addresses the known pollutant.

TN06020001 067 - 1100 HOGSKIN BRANCH Hamilton 0.77 pH NA Abandoned Mining Category 4a. EPA approved a pH TMDL that addresses the known pollutant.

94 Final Version 2010 303(d) LIST (Lower Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020001 067 - 1400 ROGERS BRANCH Hamilton 1.9 Low dissolved oxygen L Habitat loss due to stream flow alterations NA Discharges from MS4 area Upstream Impoundment Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN06020001 067 - 2000 NORTH CHICKAMAUGA CREEK Hamilton 4.08 pH NA Physical Substrate Habitat Alterations NA Abandoned Mining Municipal High Density Area Category 4a. EPA approved pH and siltation TMDLs that address the known pollutants.

TN06020001 067 - 4000 NORTH CHICKAMAUGA CREEK Hamilton Sequatchie 8.02 pH NA Abandoned Mining Category 4a. EPA has approved a pH TMDL that addresses the known pollutant.

TN06020001 087 - 1000 SHOAL CREEK Hamilton 5.4 Escherichia coli H Discharges from MS4 Area Septic Tanks Collection System Failure Stream is Category 5. (One or more uses impaired.)

TN06020001 109 - 0100 SHORT CREEK Hamilton 2.5 Escherichia coli H Discharges from MS4 Area Septic Tanks Stream is Category 5. (One or more uses impaired.)

TN06020001 109 - 0300 FRUEDENBERG CREEK Hamilton 1.4 Iron L Low Dissolved Oxygen L pH L Abandoned Mining Stream is Category 5. (One or more uses impaired.)

TN06020001 109 - 0400 BEE BRANCH Hamilton 1.55 Escherichia coli H Discharges from MS4 Area Septic Tanks Stream is Category 5. (One or more uses impaired.)

TN06020001 1240 - 0100 UNNAMED TRIB TO CITICO CREEK Hamilton 1.2 Low Dissolved Oxygen L Total Phosphorus L Escherichia coli NA Other Anthropogenic Habitat Alterations NA Collection System Failure Discharges from MS4 area Municipal High Density Area Water contact advisory.

Orchard Grove area of Chattanooga. Category 5.

EPA approved pathogen and habitat alteration TMDLs that address some of the known pollutants.

TN06020001 1240 - 1000 CITICO CREEK Hamilton 6.1 Nitrate+Nitrite L Low dissolved oxygen L Escherichia coli NA Other Anthropogenic Habitat Alterations NA Collection System Failure Discharges from MS4 area Municipal High Density Area Category 5. EPA approved pathogen and habitat alteration TMDLs that address some of the known pollutants.

TN06020001 1244 - 0100 DOBBS BRANCH Hamilton 5.3 Unionized Ammonia L Low dissolved oxygen L Escherichia coli NA Other Anthropogenic Habitat Alterations NA Collection System Failure Municipal High Density Area Category 5. EPA approved pathogen and habitat alteration TMDLs that address some of the known pollutants.

TN06020001 1244 - 0200 UNNAMED TRIB TO CHATTANOOGA CR.

Hamilton 1.4 Escherichia coli NA Other Anthropogenic Habitat Alterations NA Combined Sewer Overflows Municipal High Density Area Near Cedar Hill School.

Category 4a. EPA approved pathogen and habitat alteration TMDLs that address the known pollutants.

95 Final Version 2010 303(d) LIST (Lower Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020001 1244 - 0300 MCFARLAND SPRINGS BRANCH Hamilton 1.2 Unknown Toxicity L Escherichia coli NA Source in Other State Sources in Rossville.

Category 5. EPA approved a pathogen TMDL for some of the known pollutants. GA or EPA should do TMDL.

TN06020001 1244 - 0400 GILLESPIE SPRINGS BRANCH Hamilton 1.9 Escherichia coli M Other Anthropogenic Habitat Alterations NA Discharges from MS4 area Municipal High Density Area Category 5. Impaired, but EPA approved TMDLs for some of the known pollutants.

TN06020001 1244 - 1000 CHATTANOOGA CREEK Hamilton 8.4 PCBs NA Dioxins NA Low dissolved oxygen L Escherichia coli NA Other Anthropogenic Habitat Alterations NA Oil and Grease L Combined Sewer Overflows Discharges from MS4 area Municipal High Density Area Spills Contaminated Sediment Water contact and fishing advisories in this section.

Some contaminated sediment removed by Superfund.

Category 5. Approved PCB, dioxin, pathogen and habitat alteration TMDLs address some of the known pollutants.

TN06020001 1244 - 2000 CHATTANOOGA CREEK Hamilton 3.5 Escherichia coli NA Source in Other State Water contact advisory.

Pathogens in this section originate in GA. Category 4a.

EPA approved a pathogen TMDL for the known pollutant.

TN06020001 421 - 0100 SOUTH SUCK CREEK Marion 9.2 pH NA Abandoned Mining Category 4a. EPA approved a pH TMDL for the known pollutant.

TN06020001 421 - 0200 NORTH SUCK CREEK Marion Sequatchie 10.48 pH NA Abandoned Mining Category 4a. EPA approved a pH TMDL for the known pollutant.

TN06020001 426 - 0100 STRINGERS BRANCH Hamilton 5.8 Escherichia coli NA Other Anthropogenic Habitat Alterations NA Collection System Failure Discharges from MS4 area Municipal High Density Area Water contact advisory.

Stream heavily culverted.

Category 4a. EPA approved pathogen and habitat alteration TMDLs that address the known pollutants.

TN06020001 426 - 1000 MOUNTAIN CREEK Hamilton 3.2 Physical Substrate Habitat Alterations NA Escherichia coli M Land Development Discharges from MS4 area Category 5. Approved habitat alteration TMDL addresses some of the known pollutants.

TN06020001 497 - 1000 UNNAMED TRIB. TO CHICKAMAUGA RESERVOIR Hamilton 3.5 Biological integrity loss due to undetermined cause M Undetermined Source Near Daisy Dallas Road.

Category 5.

96 Final Version 2010 303(d) LIST (Lower Tennessee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020001 880 - 1000 ROGERS BRANCH Hamilton 10.4 Escherichia coli H Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

TN06020001 889 - 0300 WILKERSON BRANCH Hamilton 5.8 Escherichia coli H Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

TN06020001 889 - 1000 WOLFTEVER CREEK Hamilton 11.1 Escherichia coli H Discharges from MS4 Area Stream is Category 5. (One or more uses impaired.)

Hiwassee River This basin contains the following USGS Hydrologic Unit Codes: 06020002 (Hiwassee River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020002 001 - 0100 AGENCY CREEK Meigs 18.46 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 001 - 0200 GUNSTOCKER CREEK Meigs Bradley Hamilton 25.0 Escherichia coli M Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Category 5. TMDLs needed.

TN06020002 001 - 2000 HIWASSEE RIVER EMBAYMENT OF CHICKAMAUGA RESERVOIR Meigs McMinn Bradley 3130 ac Mercury L Atmospheric Deposition Industrial Point Source Fishing advisory due to mercury in largemouth bass.

Category 5. Assistance requested for atmospheric deposition TMDLs.

TN06020002 002 - 0100 SUGAR CREEK Meigs Bradley 9.0 Escherichia coli M Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Total Phosphorus L Low Dissolved Oxygen L Pasture Grazing Channelization Category 5. TMDLs needed.

TN06020002 005 - 0100 BLACK FOX CREEK Bradley 19.55 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli H Pasture Grazing Category 5. EPA approved siltation and habitat alteration TMDLs that address some of the known pollutants.

97 Final Version 2010 303(d) LIST (Hiwassee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020002 005 - 1000 CANDIES CREEK Bradley 9.65 Loss of biological integrity due to siltation NA Escherichia coli H Discharges from MS4 area Pasture Grazing Category 5. EPA approved a siltation TMDL that addresses some of known pollutants.

TN06020002 005 - 1100 BEAVERDAM BRANCH Bradley 3.07 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli H Pasture Grazing Stream is Category 5. EPA approved siltation and habitat alteration TMDLs that address some of the known pollutants.

TN06020002 005 - 1200 UNNAMED TRIB TO CANDIES CREEK Bradley 1.55 Physical Substrate Habitat Alterations NA Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved siltation and habitat alteration TMDLs that address the known pollutants..

TN06020002 005 - 1300 UNNAMED TRIB TO CANDIES CREEK Bradley 0.95 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli H Pasture Grazing Stream is Category 5.

Impaired, but EPA approved siltation and habitat alteration TMDLs that address some of the known pollutants.

TN06020002 005 - 1400 UNNAMED TRIB TO CANDIES CREEK Bradley 1.14 Loss of biological integrity due to siltation NA Undetermined Source Category 4a. Impaired, but EPA has approved a siltation TMDL that addresses the known pollutants.

TN06020002 005 - 2000 CANDIES CREEK Bradley 16.32 Physical Substrate Habitat Alterations NA Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli H Discharges from MS4 area Pasture Grazing Streambank Modifications Land Development Category 5. Impaired, but EPA has approved siltation and habitat alteration TMDLs that address some of the known pollutants.

TN06020002 005 - 3000 CANDIES CREEK Bradley 9.51 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli H Pasture Grazing Category 5. EPA approved a siltation/habitat alteration TMDL that addresses some of the known pollutants.

TN06020002 008 - 0100 BACON BRANCH Bradley 3.36 Escherichia coli H Concentrated Animal Feeding Operation (CAFO)

Animal Feeding Operations Category 5. TMDL needed.

98 Final Version 2010 303(d) LIST (Hiwassee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020002 008 - 1000 HIWASSEE RIVER EMBAYMENT OF CHICKAMAUGA RESERVOIR Bradley McMinn 1050 ac Escherichia coli NA Mercury L Undetermined Source Industrial Point Source Atmospheric Deposition Fishing advisory due to mercury. Category 5. EPA has approved a pathogen TMDL and should assist on the mercury TMDL.

TN06020002 008 - 2000 HIWASSEE RIVER EMBAYMENT OF CHICKAMAUGA RESERVOIR Bradley McMinn 505 ac Mercury L Industrial Point Source Atmospheric Deposition Fishing advisory due to mercury. Category 5. EPA should assist on the mercury atmospheric deposition TMDL.

TN06020002 009 - 0100 LITTLE SOUTH MOUSE CREEK Bradley 7.3 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Channelization Category 4a. EPA approved siltation and habitat alteration TMDLs that address the known pollutants.

TN06020002 009 - 0200 FILLAUER CREEK Bradley 7.4 Alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli NA Discharges from MS4 area Collection System Failure Category 4a. Impaired, but EPA approved pathogen, siltation and habitat alteration TMDLs that address the known pollutants.

TN06020002 009 - 0300 WOOLEN MILL BRANCH Bradley 3.92 Low Dissolved Oxygen L Habitat loss due to alteration in stream-side or littoral vegetative cover NA Nutrients M Escherichia coli NA Discharges from MS4 area Industrial Stormwater Discharges Collection System Failure Multiple fish kills due to sewage overflows. Category

5. EPA approved pathogen and habitat alteration TMDLs that addresses some of the known pollutants.

TN06020002 009 -1000 SOUTH MOUSE CREEK Bradley 12.1 Escherichia coli NA Discharges from MS4 area Pasture Grazing Category 5. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 009 - 2000 SOUTH MOUSE CREEK Bradley 6.5 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Discharges from MS4 area Collection System Failure Channelization Category 4a. EPA approved pathogen, siltation and habitat alteration TMDLs that address the known pollutants.

TN06020002 012 - 0200 LITTLE CHATATA CREEK Bradley 14.3 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli NA Discharges from MS4 area Pasture Grazing Animal Feeding Operations Category 4a. Impaired, but EPA has approved pathogen, siltation and habitat alteration TMDLs that address the known pollutants.

TN06020002 012 - 1000 CHATATA CREEK Bradley 19.62 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Discharges from MS4 area Pasture Grazing Animal Feeding Operations Category 4a. Impaired, but EPA has approved pathogen, siltation and habitat alteration TMDLs that address the known pollutants.

99 Final Version 2010 303(d) LIST (Hiwassee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020002 014 - 0100 LITTLE SOUTH CHESTUEE CREEK Bradley Polk 10.61 Loss of biological integrity due to siltation M Pasture Grazing Category 5. TMDL needed.

TN06020002 014 - 1000 SOUTH CHESTUEE CREEK Bradley 8.77 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN06020002 014 - 2000 SOUTH CHESTUEE CREEK Bradley 9.81 Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN06020002 018 - 0100 HAWKINS BRANCH Polk 1.86 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 018 - 0200 DAIRY BRANCH Polk 1.78 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 018 - 0300 SICCOWEE BRANCH Polk 3.23 Escherichia coli M Undetermined Source Category 5. TMDLs needed.

TN06020002 018 - 0550 SPRING CREEK Monroe 7.01 Loss of biological integrity due to siltation M Pasture Grazing Category 5. TMDLs needed.

TN06020002 018 - 0950 COKER CREEK Monroe 11.55 Loss of biological integrity due to siltation L Dredge Mining Category 5. Recent gold mining has impacted stream.

TN06020002 018 -2000 HIWASSEE RIVER Polk 10.9 Habitat loss due to stream flow alteration NA Temperature Alteration L Hydrostructure Flow Regulation Provides habitat for the federally listed Cumberland bean pearly mussel (Villosa trabalis), plus the tan riffleshell, sanil darter, and Ruths Golden Aster. Category 5, but flow alteration is Category 4c.

(Impacts not caused by a pollutant.)

TN06020002 018 - 3000 &

4000 HIWASSEE RIVER Polk 11.4 Habitat loss due to stream flow alteration NA Upstream Impoundment Habitat for the federally listed Cumberland bean pearly mussel (Villosa trabalis).

Section between Appalachia Dam and Powerhouse impacted by flow diversions.

Category 5, but flow alteration is Category 4c. (Impacts not caused by a pollutant.)

TN06020002 081 - 0100 CANE CREEK McMinn 13.7 Escherichia coli H Collection System Failure Category 5. TMDL needed.

100 Final Version 2010 303(d) LIST (Hiwassee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020002 081 - 0700 DRY CREEK Monroe 11.12 Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Category 5. TMDL needed.

TN06020002 081 - 1000 CONASAUGA CREEK McMinn Monroe 33.99 Loss of biological integrity due to siltation NA Municipal Urbanized Area Pasture Grazing Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

TN06020002 082 - 0300 MIDDLE CREEK McMinn Monroe 15.5 Escherichia coli H Collection System Failure Pasture Grazing Pathogens impact both recreation and the use of the creek as a domestic water supply. Category 5.

TN06020002 082 - 0800 CASON BRANCH McMinn Monroe 1.59 Flow Alteration NA Upstream Impoundment Category 4C. Impact not caused by a pollutant.

TN06020002 082 - 0900 LITTLE CHESTUEE CREEK McMinn Monroe 13.3 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 082 - 1200 TOM FOEMAN CREEK Monroe 13.1 Escherichia coli H Pasture Grazing Animal Feeding Operation Category 5. TMDL needed.

TN06020002 082 - 1300 BIG FOOT CREEK McMinn 16.0 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN06020002 082 - 2000 CHESTUEE CREEK McMinn Monroe 17.9 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 083 - 0100 BLACK BRANCH McMinn 1.98 Escherichia coli H Animal Feeding Operation Category 5. TMDL needed.

TN06020002 083 - 0110 WALKER BRANCH McMinn 1.8 Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli H Pasture Grazing Discharge from MS4 Area Category 5. TMDL needed.

TN06020002 083 - 1000 OOSTANAULA CREEK McMinn 5.7 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 083 - 2000 OOSTANAULA CREEK McMinn 21.1 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 083 - 3000 OOSTANAULA CREEK McMinn 7.4 Total Phosphorus L Loss of biological integrity due to siltation NA Escherichia coli NA Municipal Point Source Discharge Discharge from MS4 area Water contact advisory.

Category 5. EPA approved pathogen and siltation TMDLs that address some of the known pollutants.

TN06020002 083 - 4000 OOSTANAULA CREEK McMinn 8.5 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

101 Final Version 2010 303(d) LIST (Hiwassee River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020002 083 - 5000 OOSTANAULA CREEK Monroe 6.2 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 084 - 0500 DRY VALLEY CREEK McMinn 13.3 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN06020002 084 - 1000 NORTH MOUSE CREEK McMinn 22.61 Total Phosphorus L Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli NA Municipal Point Source Pasture Grazing Discharges from MS4 area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06020002 084 - 2000 NORTH MOUSE CREEK McMinn 15.61 Total Phosphorus L Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli NA Pasture Grazing Category 5. EPA approved pathogen TMDL that addresses some of the known pollutants.

TN06020002 085 - 1000 SPRING CREEK McMinn 33.8 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06020002 087 - 1000 ROGERS CREEK McMinn 21.6 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen and habitat alteration TMDLs that address the known pollutants.

TN06020002 088 - 1000 PRICE CREEK Meigs 6.9 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Channelization Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

Conasauga River This basin contains the following USGS Hydrologic Unit Codes: 03150101 (Conasauga River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN03150101 012 - 0100 SUGAR CREEK Bradley 12.2 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Escherichia coli H Pasture Grazing Septic Tanks Category 5. TMDLs needed.

102 Final Version 2010 303(d) LIST (Concasauga River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE TMDL Priority Pollutant Source COMMENTS TN03150101 012 - 0200 MILL CREEK Bradley Polk 20.1 Nitrate+Nitite L Total Phosphorus L Escherichia coli NA Pasture Grazing Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN03150101 012 - 0300 BALL PLAY CREEK Polk 7.44 Escherichia coli NA Pasture Grazing Septic Tanks Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN03150101 021 - 0100 MILLS CREEK Bradley 5.39 Escherichia coli H Concentrated Animal Feeding Operation (CAFO)

Pasture Grazing Category 5. TMDL needed.

TN03150101 021 - 0110 MARROON BRANCH Bradley 4.88 Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Category 5. TMDL needed.

TN03150101 021 - 0200 WEATHERLY BRANCH Bradley 3.98 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN03150101 021 - 0500 BLACKBURN BRANCH Bradley 7.5 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Category 5. TMDL needed.

TN03150101 021 - 1000 COAHULLA CREEK Bradley 20.9 Escherichia coli H Pasture Grazing Discharges from MS4 area Category 5. TMDL needed.

Ocoee River This basin contains the following USGS Hydrologic Unit Codes: 06020003 (Ocoee River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020003 001 - 0100 FOURMILE CREEK Polk 4.8 Escherichia coli NA Nitrate+Nitrite L Total Phosphorus L Loss of biological integrity due to siltation M Pasture Grazing Municipal Point Source Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06020003 001 - 0200 CLOUD BRANCH Polk 5.2 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN06020003 001 - 0300 COOKSON CREEK Polk 22.4 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN06020003 001 - 0400 FRY BRANCH Polk 3.8 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

103 Final Version 2010 303(d) LIST (Ocoee River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE TMDL Priority Pollutant Source COMMENTS TN06020003 001 - 1000 OCOEE RIVER Polk 13.0 pH M Zinc M Mill Tailings Mine Tailings Contaminated Sediments Impacts from Abandoned Mines Upstream Impoundment Biological integrity criteria not met below Parksville. This stream is Category 5 (impaired for one or more uses).

TN06020003 004 - 1000 &

2000 PARKSVILLE RESERVOIR.

Polk 1280 ac Copper M Iron M Zinc M Loss of biological integrity due to siltation M Mill Tailings Mine Tailings Contaminated Sediments Impacts from Abandoned Mines Parksville Reservoir fishery is improving, but sediment contamination exerts toxic effect. Category 5, impaired for one or more uses.

TN06020003 013 - 1000 OCOEE RIVER -

Parksville Res. to Ocoee #2 Dam.

Polk 7.18 Copper M Iron M Zinc M Habitat loss due to stream flow alteration NA Mill Tailings Mine Tailings Contaminated Sediments Impacts from Abandoned Mines Upstream Impoundment Use is impacted by metals and flow alteration for power generation. Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN06020003 013.5 - 1000 OCOEE NUMBER 2 Reservoir Polk 494 ac Copper M Iron M Zinc M Loss of biological integrity due to siltation M Habitat loss due to stream flow alteration NA Mill Tailings Mine Tailings Contaminated Sediments Impacts from Abandoned Mines Upstream Impoundment Upstream power generation causes flow alteration. Stream is Category 5 overall (one or more uses impaired), but flow alteration is 4c (impact not caused by a pollutant).

TN06020003 013.55-1000 OCOEE RIVER-From Res. #2 to Dam

  1. 3.

Polk 3.9 Copper M Iron M Zinc M Loss of biological integrity due to siltation M Habitat loss due to stream flow alteration NA Mill Tailings Mine Tailings Contaminated Sediments Impacts from Abandoned Mines Upstream Impoundment Upstream water diversion for power generation causes flow alteration. Category 5, but flow alteration is 4c (impact not caused by a pollutant). TVA provides flows for recreational uses per existing agreements.

TN06020003 013.7 - 1000 OCOEE NUMBER THREE RESERVOIR Polk 480 ac Copper M Iron M Zinc M Siltation M Mill Tailings Mine Tailings Contaminated Sediments Impacts from Abandoned Mines This stream is Category 5.

The stream is impaired for one or more uses.

TN06020003 013.7T- 0300 GRASSY CREEK Polk 5.4 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN06020003 014 - 0100 NORTH POTATO CREEK Polk 6.3 Physical Substrate Habitat Alterations M Copper M Iron M Zinc M pH M Loss of biological integrity due to siltation M Abandoned Mining Mine Tailings Channelization Contaminated Sediments Acid mine drainage from historical mining operations.

Erosion from historic smelting operation. Category 5. The stream is impaired for one or more uses.

104 Final Version 2010 303(d) LIST (Ocoee River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE TMDL Priority Pollutant Source COMMENTS TN06020003 014 - 0110 BURRA BURRA CREEK Polk 2.2 Copper M Iron M Zinc M pH M Loss of biological integrity due to siltation M Mill Tailings Mine Tailings Impacts from Abandoned Mines Acid mine drainage from historical mining operations.

Category 5. The stream is impaired for one or more uses.

TN06020003 014 - 0120 ELLIS BRANCH Polk 2.8 Copper M Zinc M Iron M Mill Tailings Abandoned Mining Historical mining operations.

Category 5. The stream is impaired for one or more uses.

TN06020003 014 - 0210 BELLTOWN CREEK Polk 5.1 Escherichia coli H Pasture Grazing Septic Tanks Category 5. TMDL needed.

TN06020003 014 - 1000 OCOEE RIVER Polk 2.5 Iron M Copper M Zinc M pH M Loss of biological integrity due to siltation M Mill Tailings Mine Tailings Contaminated Sediments Impacts from Abandoned Mines This stream is Category 5.

The stream is impaired for one or more uses.

TN06020003 092 - 0100 McCAMY BRANCH Polk 1.32 Flow Alteration L Upstream Impoundment Category 4c, impact not caused by a pollutant.

Sequatchie River This basin contains the following USGS Hydrologic Unit Codes: 06020004 (Sequatchie River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06020004 001 - 0120 STANDIFER BRANCH Marion 4.76 Loss of biological integrity due to siltation M Land Development Stream is Category 5. (One or more uses impaired.)

TN06020004 001 - 0121 PRYOR COVE CREEK Marion 13.12 Loss of biological integrity due to siltation M Land Development Stream is Category 5. (One or more uses impaired.)

TN06020004 001 - 0600 UNNAMED TRIB TO SEQUATCHIE RIVER Marion 2.04 Nitrate+Nitrite M Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Septic Tanks Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN06020004 001 - 0910 UNNAMED TRIB TO SHELTON CREEK Marion 6.3 Nitrate+Nitrite M Escherichia coli NA Pasture Grazing Land Application of Biosolids Category 5. Approved pathogen TMDL addresses some pollutants.

TN06020004 001 - 1000 SEQUATCHIE RIVER Marion 22.70 Mercury H Atmospheric Deposition Stream is Category 5. (One or more uses impaired.)

105 Final Version 2010 303(d) LIST (Sequatchie River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE TMDL Priority Pollutant Source COMMENTS TN06020004 001 - 1100 UNNAMED TRIB TO SEQUATCHIE RIVER Marion 1.7 Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Category 5. EPA approved pathogen TMDL addresses some pollutants.

TN06020004 001 - 1300 PECK BRANCH Marion 2.4 Escherichia coli NA Pasture Grazing Category 4a. Approved pathogen TMDL addresses the known pollutant.

TN06020004 001 - 2000 SEQUATCHIE RIVER Marion Sequatchie 15.16 Escherichia coli NA Pasture Grazing Category 4a. Approved a pathogen TMDL addresses the known pollutant.

TN06020004 005 - 0500 MCWILLIAMS CREEK Bledsoe Sequatchie 11.2 Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen TMDL addresses the known pollutant.

TN06020004 005 - 1000 SEQUATCHIE RIVER Bledsoe Sequatchie 23.1 Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen TMDL addresses the known pollutant.

TN06020004 007 - 0400 HALL CREEK Bledsoe 10.0 Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen TMDL addresses the known pollutant.

TN06020004 007 - 0600 LITTLE CREEK Bledsoe 8.7 Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen TMDL addresses the known pollutant.

TN06020004 007 - 0630 BROWNS CREEK Bledsoe 2.8 Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen TMDL addresses the known pollutant.

TN06020004 007 - 0800 SWAFFORD BRANCH Bledsoe 6.5 Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen TMDL addresses the known pollutant.

TN06020004 007 - 0900 STEPHENS BRANCH Bledsoe Cumberland 8.8 Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen TMDL addresses the known pollutant.

TN06020004 007 - 1000 SEQUATCHIE RIVER Bledsoe Cumberland 53.1 Escherichia coli NA Pasture Grazing Category 4a. EPA approved pathogen TMDL addresses the known pollutant.

TN06020004 007 - 1100 GRASSY COVE CREEK Cumberland 16.0 Alteration in stream-side or littoral vegetation M Nitrate+Nitrite M Total Phosphorus M Escherichia coli NA Pasture Grazing Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06020004 007 - 1200 MANNING SPRING Cumberland 1.4 Escherichia coli NA Pasture Grazing Category 4a. Approved pathogen TMDL addresses the known pollutant.

106 Final Version 2010 303(d) LIST (Sequatchie River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE TMDL Priority Pollutant Source COMMENTS TN06020004 007 - 1400 UNNAMED TRIB TO SEQUATCHIE RIVER Bledsoe 1.4 Escherichia coli NA Pasture Grazing Category 4a. Approved pathogen TMDL addresses the known pollutant.

TN06020004 007 - 2200 SKILLERN CREEK Bledsoe 10.60 Unknown Toxicity L Escherichia coli NA Pasture Grazing Category 5. Approved pathogen TMDL addresses some known pollutants.

TN06020004 007 - 2800 UNNAMED TRIB TO SEQUATCHIE RIVER Bledsoe 2.3 Escherichia coli NA Pasture Grazing Category 4a. Approved pathogen TMDL addresses the known pollutant.

TN06020004 008 - 0200 MAISE CREEK Bledsoe 4.7 Escherichia coli NA Pasture Grazing Category 4a. Approved pathogen TMDL addresses the known pollutant.

TN06020004 009 - 0500 GLADY FORK Sequatchie 6.43 Manganese M Other Anthropogenic Substrate Alterations M Surface Mining Stream is Category 5. (One or more uses impaired.)

TN06020004 009 - 0510 UNNAMED TRIB TO GLADY FORK Sequatchie 0.55 Loss of biological integrity due to siltation M Silviculture Harvesting Logging of area to convert to pasture put excessive silt in the stream. Category 5.

TN06020004 009 - 1000 BIG BRUSH CREEK Sequatchie 9.3 Manganese M Other Anthropogenic Substrate Alterations M Coal Mining Discharges Stream is Category 5. (One or more uses impaired.)

TN06020004 009 - 2000 BIG BRUSH CREEK Sequatchie Bledsoe 12.4 Manganese M Other Anthropogenic Substrate Alterations M Coal Mining Discharges Stream is Category 5. (One or more uses impaired.)

TN06020004 014 - 0100 DANIEL CREEK Marion 2.2 Escherichia coli NA Pasture Grazing Category 4a. Approved pathogen TMDL addresses the known pollutant.

Guntersville Reservoir This basin contains the following USGS Hydrologic Unit Codes: 06030001 (Guntersville Reservoir and misc. tribs).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06030001 055T - 0100 GRAHAM BRANCH Marion 4.89 Escherichia coli H Septic Tanks Stream is Category 5. (One or more uses impaired.)

TN06030001 057 - 0100 SWEETEN (SWEDEN) CREEK Marion 28.94 Escherichia coli H Pasture Grazing Septic Tanks Stream is Category 5. (One or more uses impaired.)

TN06030001 057 - 0121 WILDCAT BRANCH Marion 1.13 Loss of biological integrity due to siltation M Land Development Mountaintop development impacting downstream uses.

Category 5. TMDL needed.

107 Final Version 2010 303(d) LIST (Guntersville Reservoir Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE TMDL Priority Pollutant Source COMMENTS TN06030001 057 - 0140 BEENE COVE CREEK Marion 1.84 Loss of biological integrity due to siltation M Land Development Silviculture Mountaintop development impacting downstream uses.

Category 5. TMDL needed.

TN06030001 057 - 0200 TATE COVE CREEK Marion 3.72 Loss of biological integrity due to siltation M Land Development Mountaintop development impacting downstream uses.

Category 5. TMDL needed.

TN06030001 057 - 0611 UNNAMED TRIB TO LAUREL LAKE Marion 0.5 Polycyclic Aromatic Hydrocarbons M Escherichia coli NA Collection System Failure Waste Storage/Tank Leaks Laurel Lake is the water supply for Monteagle.

Category 5. Approved pathogen TMDL addresses some pollutants.

TN06030001 057 - 0921 HEDDEN BRANCH Grundy 1.55 Escherichia coli NA Pasture Grazing Septic Tanks Water contact advisory.

Category 4a. Approved pathogen TMDL addresses the known pollutant.

TN06030001 057 - 0922 CLOUSE HILL BRANCH Grundy 1.87 Escherichia coli NA Septic Tanks Same as above.

Category 4a.

TN06030001 057 - 0923 SLAUGHTER PEN HOLLOW BRANCH Grundy 1.27 Escherichia coli NA Pasture Grazing Septic Tanks Same as above.

Category 4a.

TN06030001 057 - 0924 UNNAMED TRIB TO LITTLE FIERY GIZZARD CREEK Grundy 1.54 Escherichia coli NA Pasture Grazing Septic Tanks Same as above. Category 4a.

TN06030001 057 - 0925 LITTLE FIERY GIZZARD CREEK Grundy 2.32 Flow Alteration NA Escherichia coli NA Upstream Impoundment Pasture Grazing Septic Tanks Same as above. Category 4a for pathogens, but flow alteration is 4C.

TN06030001 057 - 0950 BIG FIERY GIZZARD CREEK Marion Grundy 5.1 Flow Alteration NA Upstream Impoundment Category 4C (impairment not caused by a pollutant).

TN06030001 065 - 0100 CLUCK COVE CREEK Marion 4.32 Iron H Flow Alteration NA Loss of biological integrity due to siltation M Upstream Impoundment Land Development Category 5 overall, but flow alteration is 4C (impairment not caused by a pollutant).

TN06030001 067 - 0410 BARNES BRANCH Franklin 4.08 Iron H Flow Alteration NA Upstream Impoundment Randomly-selected for Impounded Streams Study.

Category 5 overall, but flow alteration is 4C.

TN06030001 067 - 0421 UNNAMED TRIB TO TWO MILE BRANCH Franklin 0.31 Flow Alteration NA Upstream Impoundment Randomly-selected for Impounded Streams Study.

Flow alteration is 4C.

TN06030001 067 - 0600 HOLLY FLAT COVE CREEK Marion Franklin 7.9 Loss of biological integrity due to siltation M Land Development Stream is Category 5. (One or more uses impaired.)

108 Wheeler Lake Watershed This basin contains the following USGS Hydrologic Unit Codes: 06030002 (Wheeler Lake).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06030002 1124 - 1000 HESTER CREEK Lincoln 14.8 Loss of biological integrity due to siltation M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06030002 1149 - 0100 COTTRELL SPRING BRANCH Lincoln 8.7 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Nonirrigated Crop Production This stream is Category 5.

The stream is impaired for one or more uses.

TN06030002 1149 - 0300 TROTTERS BRANCH Lincoln 16.4 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Nonirrigated Crop Production This stream is Category 5.

The stream is impaired for one or more uses.

TN06030002 1149 - 0600 BIG HUCKLEBERRY CREEK Lincoln 12.2 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Nonirrigated Crop Production This stream is Category 5.

The stream is impaired for one or more uses.

TN06030002 1149 - 1000 FLINT RIVER Lincoln 22.0 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production This stream is Category 5.

The stream is impaired for one or more uses.

TN06030002 1216 - 0200 WALKER CREEK Lincoln 12.67 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Nonirrigated Crop Production Land Development This stream is Category 5.

The stream is impaired for one or more uses.

TN06030002 1216 - 0210 WASHBURN BRANCH Lincoln 14.56 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Low Dissolved Oxygen L Nonirrigated Crop Production Upstream Impoundment This stream is Category 5.

The stream is impaired for one or more uses.

TN06030002 1216 - 0211 HARPER CREEK Lincoln 3.07 Alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing This stream is Category 5.

The stream is impaired for one or more uses.

TN06030002 1216 - 0221 UNNAMED TRIB TO HANCOCK BRANCH Lincoln 1.42 Flow Alterations NA Upstream Impoundment Category 4c for flow alteration.

109 Elk River Basin This basin contains the following USGS Hydrologic Unit Codes: 06030003 (Upper Elk River) and 06030004 (Lower Elk River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE (Pollutant)

Pollutant Source COMMENTS TN06030003 0001 - 0100 REEVES BRANCH Giles 4.1 Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06030003 010 - 1000 ELK RIVER Lincoln 13.91 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06030003 012 - 0400 ROBINSON CREEK Franklin Lincoln 11.46 Nitrate+Nitrite L Loss of biological integrity due to siltation NA Pasture Grazing Nonirrigated Crop Production Category 5. EPA approved a siltation TMDL which addresses some of the known pollutants.

TN06030003 015 - 1000 ELK RIVER Franklin Moore 15.4 Thermal Modification L Flow Alteration NA Upstream Impoundment Habitat for the federally listed shiny pigtoe and slabside pearly mussel. Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN06030003 026 - 1000 DRY CREEK Franklin 21.1 Loss of biological integrity due to siltation M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06030003 030 - 1000 BOILING FORK CREEK Franklin 32.4 Escherichia coli L Pasture Grazing Category 5. Impaired.

TN06030003 032 - 1000 WAGNER CREEK Franklin 18.8 Nitrate+Nitrite H Physical Substrate Habitat Alterations NA Escherichia coli H Urbanized High Density Area Municipal Point Source Channelization Category 5. EPA approved a habitat alteration TMDL which addresses some of the known pollutants.

TN06030003 035 -1000 ELK RIVER Franklin 6.2 Flow Alteration NA Low Dissolved Oxygen L Upstream Impoundment Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN06030003 036 - 1000 WOODS RESERVOIR Franklin Coffee 3908 ac PCBs NA Contaminated Sediments Fishing advisory due to PCBs.

Historical PCB releases from AEDC. Impaired, but EPA has approved a PCB TMDL which addresses the known pollutant.

TN06030003 041 - 0100 YELLOW BRANCH Franklin 7.1 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli H Pasture Grazing Category 5. Impaired, but EPA has approved a siltation/habitat alteration TMDL which addresses some of the known pollutants.

110 Final Version 2010 303(d) LIST (Elk River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06030003 044 - 0100 BETSY WILLIS CREEK Coffee Grundy 22.5 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli H Pasture Grazing Nonirrigated Crop Production Category 5. The stream is impaired, but EPA has approved a siltation/habitat alteration TMDL which addresses some of the known pollutants.

TN06030003 044 - 0200 PATTON CREEK Grundy 4.2 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Pasture Grazing Nonirrigated Crop Production Category 4a. Impaired, but EPA has approved a siltation/habitat alteration TMDL which addresses the known pollutants.

TN06030003 044 - 0600 DRY CREEK Grundy 13.8 Physical Substrate Habitat Alterations M Channelization Category 4a. EPA approved a habitat alteration TMDL which addresses the known pollutant.

TN06030003 044 - 0700 CALDWELL CREEK Grundy 14.1 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Escherichia coli L Nonirrigated Crop Production Pasture Grazing Municipal Point Source Stream is Category 5. (One or more uses impaired.)

TN06030003 044 - 0720 GILLIAM CREEK Grundy 0.76 Unionized Ammonia L Nitrate+Nitrite L Total Phosphorus L Sludge Deposits L Escherichia coli H Municipal Point Source Collection System Failure Monteagle STP. Stream is Category 5. (One or more uses impaired.)

TN06030003 044 - 0721 JUANITA CREEK Grundy 2.12 Unionized Ammonia L Nitrate+Nitrite L Total Phosphorus L Sludge Deposits L Escherichia coli H Municipal Point Source Collection System Failure Monteagle STP. Stream is Category 5. (One or more uses impaired.)

TN06030003 044 - 0730 TRUSSEL CREEK Grundy 4.3 Unionized Ammonia L Nitrate+Nitrite L Total Phosphorus L Iron L Manganese L Low Dissolved Oxygen L Sludge Deposits L Whole Effluent Toxicity L Municipal Point Source Discharge Upstream Impoundment Monteagle STP. Stream is Category 5. (One or more uses impaired.)

TN06030003 044 - 1000 ELK RIVER Franklin Grundy 17.9 Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

111 Final Version 2010 303(d) LIST (Elk River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06030003 053 - 0100 BLUE CREEK Franklin Coffee 10.9 Biological integrity loss due to undetermined cause L Escherichia coli H Undetermined Source Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06030003 053 - 2000 ROCK CREEK Franklin Coffee 16.1 Low Dissolved Oxygen L Nitrate+Nitrite L Total Phosphorus L Flow Alteration NA Thermal Modification L Loss of biological integrity due to siltation NA Major Municipal Point Source Discharges from MS4 area Land Development Area impacts include Tullahoma STP. Category 5, but flow alteration is 4c (impact not caused by a pollutant).

EPA approved a siltation TMDL which addresses some of the known pollutants.

TN06030003 056 - 0100 WEST FORK MULBERRY CREEK Lincoln Moore 55.9 Escherichia coli H Pasture Grazing Animal Feeding Operations Stream is Category 5. (One or more uses impaired.)

TN06030003 056 - 0250 EAST FORK MULBERRY CREEK Moore 16.8 Escherichia coli H Pasture Grazing Category 5. TMDL needed.

TN06030003 060 - 1000 CANE CREEK Lincoln Marshall 44.5 Escherichia coli NA Undetermined Source Category 4A. EPA approved a pathogen TMDL which addresses the known pollutant.

TN06030003 063 - 1000 SWAN CREEK Lincoln 5.6 Nitrate+Nitrite L Total Phosphorus L Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli M Pasture Grazing Category 5, TMDLs needed.

TN06030003 063 - 2000 SWAN CREEK Lincoln Marshall 9.9 Nitrate+Nitrite L Total Phosphorus L Low Dissolved Oxygen L Escherichia coli NA Animal Feeding Operation (NPS)

Fish kills from animal feeding operation. Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06030003 085 - 1000 CHILDER CREEK Franklin 8.9 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover NA Nonirrigated Crop Production Category 4a. EPA approved siltation/habitat alteration TMDL that addresses the known pollutants.

TN06030003 552 - 1000 GUM CREEK Franklin 12.9 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Nonirrigated Crop Production Channelization Category 4a. EPA approved a siltation/habitat alteration TMDL which addresses the known pollutants.

TN06030003 567 - 1000 HESSEY BRANCH Franklin 9.6 Nutrients H Physical Substrate Habitat Alteration NA Loss of biological integrity due to siltation NA Nonirrigated Crop Production Pasture Grazing Channelization Category 5. EPA approved siltation/habitat alteration TMDL which addresses some of the known pollutants.

112 Final Version 2010 303(d) LIST (Elk River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06030004 013 - 1000 ELK RIVER Giles 7.4 Escherichia coli H Pasture Grazing Habitat for two federally listed fish species: the snail darter (Percina tanasi) and the boulder darter (Etheostoma wapiti). Category 5.

TN06030004 017 - 0300 EVERLY BRANCH Giles 2.41 Loss of biological integrity due to siltation NA Sand/Gravel/Rock Mining Category 4a. EPA approved a siltation TMDL which addresses the known pollutant.

TN06030004 017 - 0600 UNNAMED TRIB TO RICHLAND CREEK Giles 3.2 Other Anthropogenic Substrate Alterations NA Loss of biological integrity due to siltation NA Industrial/Commercial Site Stormwater Discharge Category 4a. EPA approved a siltation/habitat alteration TMDL which addresses the known pollutants.

TN06030004 017 - 0700 UNNAMED TRIB TO RICHLAND CREEK Giles 1.28 Habitat loss due to alteration in stream-side or littoral vegetative cover NA Physical Substrate Habitat Alterations NA Loss of biological integrity due to siltation NA Municipal Urbanized Area Channelization Category 4a. Impaired, but EPA has approved a siltation/habitat alteration TMDL which addresses the known pollutants.

TN06030004 017 - 0800 PLEASANT RUN CREEK Giles 1.7 Nitrate+Nitrite L Total Phosphorus L Habitat loss due to alteration in stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Escherichia coli H Municipal Urbanized Area Collection System Failure Category 5. EPA approved a siltation/habitat alteration TMDL which addresses some of the known pollutants.

TN06030004 017 - 2000 RICHLAND CREEK Giles 26.7 Loss of biological integrity due to siltation NA Escherichia coli NA Collection System Failure Land Development Municipal Urbanized Area Pasture Grazing Pulaski area impacts.

Category 4a. EPA approved pathogen and habitat alteration TMDLs that address the known pollutants.

TN06030004 023 - 1000 ROBERTSON FORK CREEK Giles Marshall 16.64 Escherichia coli H Pasture Grazing Category 5. The stream is impaired for one or more uses.

TN06030004 026_0111 UNNAMED TRIB TO ANDERSON CREEK Giles Lawrence 1.19 Loss of biological integrity due to siltation M Off-road Vehicles Category 5. The stream is impaired for one or more uses.

TN06030004 026_0112 FANNY BRANCH Giles Lawrence 2.18 Loss of biological integrity due to siltation M Off-road Vehicles Silviculture Category 5. The stream is impaired for one or more uses.

113 Final Version 2010 303(d) LIST (Elk River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06030004 026_0115 ANDERSON CREEK Giles 0.54 Loss of biological integrity due to siltation M Off-road Vehicles Category 5. The stream is impaired for one or more uses.

TN06030004 029_0410 UNNAMED TRIB TO WET WEAKLEY CREEK Lawrence 0.75 Unionized Ammonia L Loss of biological integrity due to siltation M Escherichia coli H Animal Feeding Operations Silviculture Category 5. The stream is impaired for one or more uses.

TN06030004 043 - 0300 CORN CREEK Marshall 4.0 Loss of biological integrity due to siltation NA Nutrients L Escherichia coli NA Pasture Grazing Unrestricted Cattle Access Category 5. EPA approved pathogen and habitat alteration TMDLs that address some of the known pollutants.

TN06030004 043 - 0400 TOWN CREEK Marshall 12.5 Nitrate+Nitrite L Total Phosphorus L Escherichia coli NA Pasture Grazing Municipal Point Source Discharges Town Creek impacts include Cornersville STP. Category 5.

EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06030004 043 - 0600 COFFEY BRANCH Marshall 3.4 Escherichia coli NA Pasture Grazing Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06030004 043 - 1000 RICHLAND CREEK Giles Marshall 42 Escherichia coli NA Pasture Grazing Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant.

Pickwick - Shoal Creek Basin This basin contains the following USGS Hydrologic Unit Codes: 06030005 (Pickwick Reservoir, including Shoal Creek).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06030005 078 - 0410 UNNAMED TRIB TO WOLF CREEK Lawrence 0.13 Flow Alterations NA Upstream Impoundment Category 4C. Impact not caused by a pollutant.

TN06030005 082 - 0100 TRIPPTOWN BRANCH (previously called BIG DRY BRANCH)

Lawrence 7.4 Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Category 5. The stream is impaired for one or more uses.

TN06030005 082 - 1000 SHOAL CREEK Lawrence 2.3 Escherichia coli NA Collection System Failure Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

114 Upper Kentucky Reservoir This basin contains the following USGS Hydrologic Unit Codes: 06040001 (Upper Kentucky Reservoir).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE /TMDL Priority Pollutant Source COMMENTS TN06040001 043 - 0100 CHALK CREEK Hardin 14.0 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Pasture Grazing Channelization Stream is Category 5. (One or more uses impaired.)

TN06040001 043 - 0200 MUD CREEK Hardin 13.4 Loss of biological integrity due to siltation M Low dissolved oxygen M Physical Substrate Habitat Alterations M Pasture Grazing Channelization Stream is Category 5. (One or more uses impaired.)

TN06040001 043 - 0820 BINGHAM CREEK Hardin Henderson 8.5 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN06040001 043 - 1000 WHITEOAK CREEK Hardin 15.1 Loss of biological integrity due to siltation M Low dissolved oxygen M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN06040001 054 - 1000 SNAKE CREEK McNairy Hardin 9.3 Low dissolved oxygen M Loss of biological integrity due to siltation M Municipal Point Source Irrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06040001 060 - 0300 WARDLOW CREEK McNairy 10.92 Loss of biological integrity due to siltation M Pasture Grazing Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06040001 060 - 2000 CHAMBERS CREEK McNairy 4.0 Loss of biological integrity due to siltation M Low dissolved oxygen M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06040001 364 - 3000 EAGLE CREEK Benton Decatur 5.1 Unionized Ammonia NA Low dissolved oxygen NA Escherichia coli H Minor Municipal Point Source Onsite Wastewater System (Septic Tanks)

Category 5. EPA approved an ammonia/dissolved oxygen TMDL that addresses some of the known pollutants.

TN06040001 651 - 1000 GOODIN BRANCH Decatur 2.87 Habitat loss due to stream flow alteration NA Upstream Impoundment Category 4c. Impacts are not caused by a pollutant.

TN06040001 802 - 1650 BROWNS CREEK Henderson 0.3 Temperature Alterations L Habitat loss due to stream flow alteration NA Upstream Impoundment Poor quality discharges from Browns Reservoir. Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN06040001 991 - 1000 ROBERTS CREEK Humphreys 4.4 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Silviculture Harvesting/Residue Management Forestry clearcut without proper BMPs. Category 5.

(One or more uses impaired.)

TN06040001 1000 - 0150 JACK BRANCH Humphreys 1.0 Loss of biological integrity due to siltation M Habitat loss due to alteration in stream-side or littoral vegetative cover M Silviculture Harvesting/Residue Management Same as above. Stream is Category 5. (One or more uses impaired.)

115 Final Version 2010 303(d) LIST (Upper Kentucky Reservoir Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040001 1000 - 0200 NORTH FORK BLUE CREEK Humphreys 7.4 Loss of biological integrity due to siltation M Habitat loss due to alteration in stream-side or littoral vegetative cover M Silviculture Harvesting/Residue Management Same as above. Stream is Category 5. (One or more uses impaired.)

TN06040001 1163 - 0110 UNNAMED TRIB TO LITTLE BEECH CR.

Wayne 5.6 Loss of biological integrity due to siltation M Habitat loss due to alteration in stream-side or littoral vegetative cover M Unrestricted Cattle Access Stream is Category 5. (One or more uses impaired.)

TN06040001 1163 - 2000 BEECH CREEK Wayne 6.0 Mercury L Unknown Source Mercury discovered in creek sediment near Leatherwood.

Stream is Category 5. (One or more uses impaired.)

TN06040001 1163 - 3000 BEECH CREEK Wayne 6.2 PCBs L CERCLA site Stream is Category 5. (One or more uses impaired.)

Duck River Basin This basin contains the following USGS Hydrologic Unit Codes: 06040002 (Upper Duck River) and 06040003 (Lower Duck River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040002 002 - 0300 GLOBE CREEK Maury Marshall 22.66 Escherichia coli H Pasture Grazing Stream is Category 5. One or more uses are impaired.

TN06040002 002 - 0310 EAST FORK OF GLOBE CREEK Marshall 8.8 Unionized Ammonia L Chloride L Escherichia coli M Landfill Pasture Grazing Category 5. TMDLs needed.

TN06040002 002 - 0700 HURRICANE CREEK Maury 12.7 Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. One or more uses are impaired.

TN06040002 002 - 3000 FOUNTAIN CREEK Maury 7.9 Escherichia coli NA Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06040002 008 - 1000 CEDAR CREEK Maury Marshall 7.62 Nitrates L Escherichia coli H Pasture Grazing Non-irrigated Crop Production Stream is Category 5. One or more uses are impaired.

TN06040002 010 - 0100 RICH CREEK Marshall Bedford 10.81 Nitrates L Escherichia coli H Pasture Grazing Non-irrigated Crop Production Stream is Category 5. One or more uses are impaired.

116 Final Version 2010 303(d) LIST (Duck River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040002 012 - 0100 EAST ROCK CREEK Marshall 14.17 Nitrates L Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli H Pasture Grazing Category 5. EPA approved a siltation/habitat alteration TMDL that addresses some of the known pollutants.

TN06040002 012 - 0400 COLLINS CREEK Marshall 5.3 Loss of biological integrity due to siltation M Pasture Grazing Non-irrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06040002 012 - 0500 SANDERS CREEK Marshall 4.5 Loss of biological integrity due to siltation M Alteration in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06040002 012 - 0700 SNELL BRANCH Marshall 4.5 Loss of biological integrity due to siltation NA Alteration in stream-side or littoral vegetative cover NA Land Development Channelization Category 4a. EPA approved a siltation/habitat alteration TMDL that addresses the known pollutants.

TN06040002 012 - 2000 BIG ROCK CREEK Marshall 9.0 Nitrates L Loss of biological integrity due to siltation NA Low dissolved oxygen L Major Municipal Point Source Discharges from MS4 area Lewisburg area impacts.

Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06040002 012 - 3000 BIG ROCK CREEK Marshall 6.0 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations M Low Dissolved Oxygen L Escherichia coli H Pasture Grazing Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06040002 020 - 1000 DUCK RIVER Bedford 29.8 Escherichia coli H Discharges from MS4 area Shelbyville area pathogen sources. Stream is Category 5.

(One or more uses impaired.)

TN06040002 021 - 0100 LITTLE SINKING CREEK Bedford 7.6 Loss of biological integrity due to siltation NA Alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. EPA approved siltation and pathogen TMDLs that address the known pollutants.

TN06040002 021 - 1000 SINKING CREEK Bedford 12.0 Loss of biological integrity due to siltation NA Alteration in stream-side or littoral vegetative cover NA Pasture Grazing Category 4a. EPA approved pathogen and siltation TMDLs that address the known pollutants.

TN06040002 024 - 0100 DAVIS BRANCH Bedford 2.2 Loss of biological integrity due to siltation NA Pasture Grazing Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

117 Final Version 2010 303(d) LIST (Duck River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040002 024 - 1000 SUGAR CREEK Bedford 21.7 Nitrates L Phosphates L Alteration in stream-side or littoral vegetative cover M Escherichia coli H Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06040002 027 - 0200 BOMAR CREEK Bedford 4.1 Nutrients L Low dissolved oxygen L Discharges from MS4 Area Shelbyville area impacts.

Category 5. (One or more uses impaired.)

TN06040002 027 - 1000 DUCK RIVER Bedford 1.6 Escherichia coli NA Loss of biological integrity due to siltation NA Collection System Failure Discharges from MS4 area Shelbyville area impacts.

Category 4a. EPA approved siltation and pathogen TMDLs that addresses the known pollutants.

TN06040002 030 - 0200 DODDY CREEK Bedford 2.2 Habitat loss due to flow alteration NA Upstream Impoundment Category 4c. Impacts are not caused by a pollutant.

TN06040002 030 - 1000 DUCK RIVER Bedford 12.1 Thermal Modification L Flow Alteration NA Manganese M Upstream Impoundment Duck River impacted by discharges from Normandy.

TVA has attempted to improve dissolved oxygen conditions downstream of dam. Category 5, flow alteration is 4c (impact not due to pollutant).

TN06040002 032 - 0300 CLEAR BRANCH Coffee 7.3 Alteration of stream-side or littoral vegetation M Phosphate NA Low dissolved oxygen NA Escherichia coli NA Dairies Pasture Grazing Category 5. EPA approved DO, nutrient, and pathogen TMDLs for this stream that address some of the known pollutants.

TN06040002 032 - 0310 MUDDY BRANCH Coffee 5.1 Alteration of stream-side or littoral vegetation M Phosphate NA Low dissolved oxygen NA Escherichia coli NA Dairies Pasture Grazing Category 5. EPA approved DO, nutrient, and pathogen TMDLs for this stream that address some of the known pollutants.

TN06040002 032 - 2000 DUCK RIVER Coffee 1.25 Escherichia coli NA Collection System Failure Water contact advisory due to elevated bacteria levels from Manchester area sewer overflows and urban runoff.

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

118 Final Version 2010 303(d) LIST (Duck River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040002 033 - 0300 BELL BUCKLE CREEK Bedford 11.1 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Minor Municipal Point Source Unrestricted Cattle Access Bell Buckle area impacts, incl.

Bell Buckle STP. Category 4a.

EPA approved siltation/habitat alteration and pathogen TMDLs that address the known pollutants.

TN06040002 033 - 0600 MUSE CREEK Bedford 3.0 Loss of biological integrity due to siltation M Alterations in stream-side or littoral vegetative cover M Unrestricted Cattle Access Stream is Category 5. One or more uses are impaired.

TN06040002 033 - 1000 WARTRACE CREEK Bedford 15.0 Escherichia coli M Pasture Grazing Category 5. TMDLs needed.

TN06040002 038 - 0300 HURRICANE CREEK Bedford 22.03 Escherichia coli NA Loss of biological integrity due to siltation NA Other Habitat Alterations NA Pasture Grazing Category 4a. EPA approved siltation/habitat alteration and pathogen TMDLs that address the known pollutants.

TN06040002 038 - 1000 FALL CREEK Bedford 11.4 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06040002 039 - 0200 WEAKLEY CREEK Bedford 6.2 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06040002 039 - 0250 WEAKLEY CREEK Bedford Rutherford 13.1 Loss of biological integrity due to siltation NA Nutrients NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved siltation, nutrient, and pathogen TMDLs that address the known pollutants.

TN06040002 039 - 0300 ALEXANDER CREEK Bedford Rutherford 21.1 Loss of biological integrity due to siltation NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved siltation and pathogen TMDLs that address the known pollutants.

TN06040002 039 - 1000 NORTH FORK CREEK Bedford 3.7 Escherichia coli M Pasture Grazing Category 5. TMDLs needed.

TN06040002 039 - 2000 NORTH FORK CREEK Bedford 4.0 Escherichia coli NA Nutrients NA Pasture Grazing Category 4a. EPA approved nutrient and pathogen TMDLs that address the known pollutants.

TN06040002 039 - 3000 NORTH FORK CREEK Bedford 9.2 Loss of biological integrity due to siltation NA Nutrients NA Escherichia coli M Pasture Grazing Category 5. EPA approved siltation and nutrient TMDLs that address some of the known pollutants.

119 Final Version 2010 303(d) LIST (Duck River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040002 046 - 1000 WILSON CREEK Marshall Bedford 19.5 Escherichia coli NA Nitrate NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved habitat alteration, nutrient, and pathogen TMDLs that address the known pollutants.

TN06040002 047 - 0100 WEST FORK Marshall Williamson 3.5 Alterations in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. One or more uses are impaired.

TN06040002 047 - 0200 EAST FORK Marshall Rutherford 3.1 Alterations in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. One or more uses are impaired.

TN06040002 047 - 0300 LICK CREEK Marshall Rutherford 8.8 Escherichia coli NA Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06040002 047 - 1000 SPRING CREEK Marshall Rutherford 13.2 Escherichia coli NA Unrestricted Cattle Access Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06040002 048 - 0100 THICK CREEK Marshall Williamson 13.4 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Escherichia coli NA Pasture Grazing Category 4a. EPA approved siltation, habitat alteration, and pathogen TMDLs that address the known pollutants.

TN06040002 048 - 1000 CANEY CREEK Marshall Williamson 13.1 Nitrate NA Loss of biological integrity due to siltation NA Unrestricted Cattle Access Category 4a. EPA approved siltation and nutrient TMDLs that address the known pollutants.

TN06040002 049 - 0400 WALLACE BRANCH Maury Williamson 3.8 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06040002 502 - 0220 SHANKLIN BRANCH Coffee 4.87 Alteration to stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. One or more uses are impaired.

TN06040002 502 - 0230 ROAN BUCK BRANCH Coffee 3.83 Alteration to stream-side or littoral vegetative cover M Low Dissolved Oxygen L Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. One or more uses are impaired.

TN06040002 502 - 1000 LITTLE DUCK RIVER Coffee 10.6 Escherichia coli NA Collection System Failure Water contact advisory due to Manchester area collection system problems. Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

120 Final Version 2010 303(d) LIST (Duck River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040003 001 - 2000 DUCK RIVER Humphreys 16.46 Mercury L Atmospheric Deposition Elevated mercury levels in gamefish. EPA should take the lead on atmospheric deposition TMDLs.

TN06040003 005 - 1000 DUCK RIVER Humphreys Hickman 4.05 Mercury L Atmospheric Deposition Elevated mercury levels in gamefish. EPA should take the lead on atmospheric deposition TMDLs.

TN06040003 019 - 0200 PATTERSON CREEK Maury 5.8 Alteration to stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. One or more uses are impaired.

TN06040003 019 - 2000 BIG BIGBY CREEK Maury 4.6 Nitrate L Phosphate L Escherichia coli NA Major Municipal Point Source Pasture Grazing Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06040003 023 - 0100 QUALITY CREEK Maury 7.1 Unionized Ammonia L Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Minor Industrial Point Source Urbanized High Density Area Category 5. EPA approved a siltation/habitat alteration TMDL that addresses some of the known pollutants.

TN06040003 023 - 0200 SUGAR CREEK Maury 13.6 Loss of biological integrity due to siltation NA Salinity/TDS/Chlorides M Other Habitat Alterations NA Urbanized High Density Area Landfills Smelter Services & Associated Commodity landfills. Category

5. EPA approved a siltation/habitat alteration TMDL that addresses some of the known pollutants.

TN06040003 023 - 1000 SUGAR FORK Maury 1.77 Solids M Phosphate L Nitrates L Escherichia coli NA Major Municipal Point Source Mt Pleasant area sources include STP. Category 5.

EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06040003 023 - 2000 SUGAR FORK Maury 1.13 Loss of biological integrity due to siltation M Phosphate L Nitrates L Escherichia coli NA Collection System Failure Urbanized High Density Area Mt Pleasant area sources.

Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06020002 024 - 0100 BEASLEY HOLLOW Maury 0.79 Flow Alteration NA Low Dissolved Oxygen L Upstream Impoundment Category 5. Flow alteration is 4c, impact not due to pollutant.

TN06040003 026 - 1000 DUCK RIVER Maury 7.43 Phosphate L Low Dissolved Oxygen L Major Municipal Point Source Discharges from MS4 Area Columbia area impacts.

Stream is Category 5. (One or more uses are impaired.)

121 Final Version 2010 303(d) LIST (Duck River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040003 027 - 0100 UNNAMED TRIB TO LITTLE BIGBY CR.

Maury 2.0 Physical Substrate Habitat Alterations M Discharges from MS4 area Channelization Stream is Category 5. (One or more uses impaired.)

TN06040003 027 - 1000 LITTLE BIGBY CREEK Maury 18.77 Loss of biological integrity due to siltation M Discharges from MS4 area Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN06040003 030 - 0100 UNNAMED TRIB TO LYTLE CREEK Maury 1.6 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Discharges from MS4 area Channelization Category 4a. Impaired, but EPA approved siltation/habitat alteration TMDLs that address the known pollutants.

TN06040003 030 - 1000 LYTLE CREEK Maury 2.4 Loss of biological integrity due to siltation NA Discharges from MS4 area Highway Construction Category 4a. EPA approved a siltation TMDL that addresses the known pollutant.

TN06040003 034 - 0260 COLEMAN BRANCH Maury 1.02 Loss of biological integrity due to siltation M Land Development Discharges from MS4 area Category 5. TMDLs needed.

TN06040003 034 - 0300 MCCUTCHEON CREEK Maury Williamson 12.27 Loss of biological integrity due to siltation NA Land Development Discharges from MS4 area Category 4a. Impaired, but EPA approved a siltation TMDL for the known pollutant.

TN06040003 034 - 0410 GRASSY BRANCH Maury Williamson 7.18 Alteration in Stream-side or littoral vegetative cover NA Loss of biological integrity due to siltation NA Land Development Urbanized High Density Area Category 4a. EPA approved a siltation/habitat alteration TMDL that addresses the known pollutants.

TN06040003 034 - 0700 CROOKED CREEK Maury 2.5 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations NA Pasture Grazing Category 4a. EPA approved a siltation/habitat alteration TMDL that addresses the known pollutants.

TN06040003 034 - 2000 &

3000 RUTHERFORD CREEK Maury Williamson 12.5 Loss of biological integrity due to siltation NA Nitrates L Phosphate L Minor Municipal Point Source Land Development Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN06040003 041 - 0800 POTTS BRANCH Maury 2.9 Escherichia coli NA Confined Animal Feeding Operation (nonpoint)

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06040003 041 - 0950 LUNNS BRANCH Hickman Maury 2.4 Escherichia coli NA Concentrated Animal Feeding Operation (permitted point)

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06040003 041 - 1150 DOG BRANCH Maury 2.0 Escherichia coli NA Concentrated Animal Feeding Operation (permitted point)

Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN06040003 050 - 0620 GRAB BRANCH Dickson 3.94 Escherichia coli H Pasture Grazing Discharges from MS4 area Stream is Category 5. One or more uses are impaired.

122 Final Version 2010 303(d) LIST (Duck River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040003 062 - 3000 BLUE CREEK Humphreys 5.1 Nitrates L Phosphate L Low dissolved oxygen L Solids M Escherichia coli NA Minor Municipal Point Source McEwen STP. Category 5.

EPA approved a pathogen TMDL that addresses some of the known pollutants.

Buffalo River This basin contains the following USGS Hydrologic Unit Codes: 06040004 (Buffalo River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040004 001 - 0250 BLACK BRANCH Humphreys 8.9 Polycyclic Aromatic Hydrocarbons (PAHs) L Leaking Underground Storage Tanks Petroleum products being lost from business(es) near I-40.

Stream is Category 5. (One or more uses impaired.)

TN06040004 001 - 0900 TANYARD CREEK Humphreys Perry 2.1 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Logging Road Construction/

Maintenance Silviculture Road constructed for forestry activities without proper BMPs Category 5. (One or more uses impaired.)

TN06040004 001 - 1000 BUFFALO RIVER Humphreys Perry 38.3 Mercury L Atmospheric Deposition Undetermined Source Fishing advisory due to mercury. Category 5. EPA assistance requested on TMDLs which include atmospheric deposition.

TN06040004 013 - 0110 SQUAW BRANCH Lewis Lawrence 4.33 Flow Alteration NA Low Dissolved Oxygen L Upstream Impoundment Category 5 overall, but flow alteration is 4c (impact not caused by a pollutant).

TN06040004 013 - 0150 CHIEF CREEK Lewis Lawrence 3.98 Flow Alteration NA Upstream Impoundment Impacted by lack of flow and poor quality releases from Maddox Lake. Category 4c.

Impacts not due to a pollutant.

TN06040004 013 - 0200 WEAVER BRANCH Lawrence 1.3 Habitat loss due to stream flow alteration NA Low dissolved oxygen L Upstream Impoundment Impacted by lack of flow and poor quality releases from VFW Lake. Category 5, but flow alteration is 4c (impact not caused by a pollutant).

123 Final Version 2010 303(d) LIST (Buffalo River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040004 025 - 0200 BOOKER HOLLOW Lewis 1.8 Nitrate L Phosphate L Low dissolved oxygen L Thermal Modification L Escherichia coli NA Municipal Point Source Discharges Failing Collection System Hohenwald area impacts include collection system problems and poor quality effluent from the sewage treatment plant. Category 5.

EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06040004 025 - 2000 ROCKHOUSE CREEK Lewis 5.1 Phosphate L Nitrate L Physical Substrate Habitat Alterations H Escherichia coli NA Municipal Point Source Dredging Same as above. Stream is Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

Lower Kentucky Reservoir This basin contains the following USGS Hydrologic Unit Codes: 06040005 (Lower Kentucky Reservoir).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040005 019 - 1000 BLOOD RIVER Henry 5.6 Physical Substrate Habitat Alterations L Nonirrigated Crop Production Channelization Stream shared with Kentucky.

Headwaters in Tennessee are channelized. Category 5. (One or more uses impaired.)

TN06040005 038 - 0100 WEST SANDY EMBAYMENT Henry 3.7 ac Nutrients L Low dissolved oxygen L Loss of biological integrity due to siltation L Septic Tanks Upstream Impoundment Stream is Category 5. (One or more uses impaired.)

TN06040005 020T - 0510 UNNAMED TRIB TO FORD CREEK Benton 3.53 Flow Alteration NA Upstream Impoundment Creek is impacted by lack of flow and poor quality releases from Blackburn Lake. Category 4c.

Impact not caused by a pollutant.

TN06040005 023 - 0500 CLIFTY CREEK Henry 15.8 Low dissolved oxygen L Loss of biological integrity due to siltation L Pasture Grazing Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06040005 024 - 0111 UNNAMED TRIB TO TOWN CREEK Henry 0.55 Flow Alteration NA Upstream Impoundment Creek is impacted by lack of flow and poor quality releases from Green Acres Lake. Category 4c.

Impact not caused by a pollutant.

124 Final Version 2010 303(d) LIST (Lower Kentucky Reservoir Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040005 024 - 0113 THREEMILE BRANCH Henry 4.72 Flow Alteration NA Upstream Impoundment Creek is impacted by lack of flow and poor quality releases from Smith Lake. Category 4c.

Impact not caused by a pollutant.

TN06040005 024 - 1000 HOLLY FORK CREEK Henry 13.8 Nitrates L Escherichia coli NA Physical Substrate Habitat Alterations M Animal Feeding Operations (NPS)

Channelization Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06040005 024 -1310 HOLLOW ROCK BRANCH Carroll 11.71 Alteration in stream-side or littoral vegetative cover M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06040005 027 - 0350 DRY CREEK Benton 1.4 Flow Alteration NA Upstream Impoundment Impacted by lack of flow and poor quality releases from Cedar Lake #2. Category 4c (impacts not caused by a pollutant.)

TN06040005 032 - 0150 MAPLE CREEK Carroll 4.0 Flow Alterations NA Upstream Impoundment Creek impacted by poor quality releases from Maple Creek Lake.

Stream is Category 4c. Impacts not caused by a pollutant.

TN06040005 032 - 0700 BIG BEAVER CREEK Henderson 13.13 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN06040005 032 - 0720 LITTLE BEAVER CREEK Henderson 5.84 Nitrates L Phosphate L Physical Substrate Habitat Alterations M Escherichia coli NA Pasture Grazing Channelization Category 5. Uses are impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN06040005 032 - 0900 MUD CREEK Carroll Henderson 8.53 Nutrients L Low dissolved oxygen L Escherichia coli NA Pasture Grazing Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN06040005 032 - 1000 BIG SANDY RIVER Carroll 7.3 Escherichia coli NA Pasture Grazing Category 4a. Impaired, but EPA has approved a pathogen TMDL that addresses known pollutants.

TN06040005 032 - 2000 BIG SANDY RIVER Carroll Henderson 12.5 Nitrates L Phosphates L Low dissolved oxygen L Escherichia coli NA Pasture Grazing Category 5. Uses are impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN06040005 050 - 2000 TRACE CREEK Humphreys 8.4 Loss of biological integrity due to siltation M Nitrates L Phosphate L Low dissolved oxygen L Physical Substrate Habitat Alterations M Major Municipal Point Source Land Development Waverly area impacts, including Waverly STP. Stream is Category 5. (One or more uses impaired.)

125 Final Version 2010 303(d) LIST (Lower Kentucky Reservoir Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040005 063 - 0250 SOUTH FORK HURRICANE CREEK Houston 3.3 Flow alteration NA Low Dissolved Oxygen L Upstream Impoundment Creek is impacted by lack of flow and poor quality releases from Lakeview Circle Lake. Category 5, but flow alteration is 4c, impact not caused by a pollutant.

TN06040005 870 - 0310 CHARLIE CREEK Benton 4.6 Flow Alteration NA Low Dissolved Oxygen L Upstream Impoundment Creek is impacted by lack of flow and poor quality releases from Shannon Lake. Category 5.

Flow alteration is 4c (impact not caused by a pollutant).

East Fork Clarks River This basin contains the following USGS Hydrologic Unit Codes: 06040006 (East Fork Clarks River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN06040006 014 - 0100 WHITE OAK CREEK Henry 1.09 Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06040006 014 - 0200 DRY CREEK Henry 4.99 Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06040006 014 - 0300 PLEASANT GROVE CREEK Henry 1.63 Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN06040006 014 - 1000 EAST FORK CLARKS RIVER Henry 5.90 Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. TMDL needed.

Mississippi River Basin This basin contains the following USGS Hydrologic Unit Codes: 08010100 (Mississippi River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010100 001 - 0100 HARRIS DITCH Lake 7.58 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010100 001 - 0110 OLD GRAVEYARD SLOUGH Lake 13.01 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization Near Tiptonville. Stream is Category 5. (One or more uses impaired.)

126 Final Version 2010 303(d) LIST (Mississippi River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010100 001 - 0200 BLUE BANK BAYOU Lake 15.46 Nitrate+Nitrite M Loss of biological integrity due to siltation M Escherichia coli H Nonirrigated Crop Production Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010100 001 - 0320 COLD CREEK Lauderdale 42.2 Escherichia coli H Pasture Grazing Randomly selected for statewide Wadeable Streams Study. Category 5. (One or more uses impaired.)

TN08010100 001 -1000 MISSISSIPPI RIVER Shelby 24.9 Mercury L PCBs H Dioxin H Chlordane H Physical Substrate Habitat Alterations L Atmospheric Deposition Dredging Contaminated Sediments Sources Outside the State Fishing advisory originally due to chlordane. Category 5.

(One or more uses impaired.)

EPA should develop TMDLs for this large interstate water.

TN08010100 001 - 1100 MCKELLAR LAKE Shelby 13.0 Mercury L PCBs L Chlordane L Dioxin L Nitrate+Nitrite L Loss of biological integrity due to siltation L Low dissolved oxygen L Escherichia coli L Atmospheric Deposition Collection System Failure Discharges from MS4 area Dredging Contaminated Sediment Fishing advisory originally due to chlordane. McKellar Lake is not really a lake. Category 5.

(One or more uses impaired.)

EPA assistance requested on TMDLs which involve atmospheric deposition.

TN08010100 001 - 2000 MISSISSIPPI RIVER Shelby Tipton 40.0 PCBs L Dioxin L Chlordane L Physical Substrate Habitat Alterations L Dredging Contaminated Sediment Stream is Category 5. (One or more uses impaired.) EPA should develop TMDLs for this large interstate water.

TN08010100 001 - 3000 MISSISSIPPI RIVER Tipton Lauderdale 45.2 PCBs L Dioxin L Chlordane L Physical Substrate Habitat Alterations L Dredging Contaminated Sediment Stream is Category 5. (One or more uses impaired.) EPA should develop TMDLs for this large interstate water.

TN08010100 001 - 4000 MISSISSIPPI RIVER Dyer Lake 74.0 PCBs L Dioxin L Chlordane L Physical Substrate Habitat Alterations L Dredging Contaminated Sediment Category 5. Habitat for federally listed pallid sturgeon (Scaphirhynchus albus). EPA should develop TMDLs for this large interstate water.

TN08010100 001 - 5000 MISSISSIPPI RIVER Lake 10.2 PCBs L Dioxin L Chlordane L Physical Substrate Habitat Alterations L Dredging Contaminated Sediment Stream is Category 5. (One or more uses impaired.) EPA should develop TMDLs for this large interstate water.

127 Obion River Basin This basin contains the following USGS Hydrologic Unit Codes: 08010202 (Obion River and North Fork Obion River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE TMDL Priority Pollutant Source COMMENTS TN08010202 001 - 0200 JOHNSON CREEK Obion Dyer 10.9 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 001 - 1000 OBION RIVER Dyer 28.6 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli H Nonirrigated Crop Production Channelization Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010202 001 - 2000 OBION RIVER Dyer 23.0 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 001-3000 OBION RIVER Dyer Obion 14.0 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli M Nonirrigated Crop Production Channelization Undetermined Source Category 5. TMDLs needed.

TN08010202 001 - 4000 OBION RIVER Obion 7.6 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Source Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010202 003 - 0100 COOL SPRINGS BRANCH Dyer Gibson 22.1 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Low Dissolved Oxygen M Nonirrigated Crop Production Channelization Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010202 003 - 1000 REEDS CREEK Dyer Gibson 8.3 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 009 - 0200 TOMMY CREEK Weakley 7.4 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010202 009 - 0700 HURRICANE CREEK Weakley 2.2 Escherichia coli NA Pasture Grazing Category 4A. Impaired, but EPA approved a pathogen TMDL that addresses the known pollutants.

128 Final Version 2010 303(d) LIST (Obion River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010202 009 - 0710 HURRICANE CREEK Weakley 13.6 Nitrate+Nitrite M Loss of biological integrity due to siltation M Alteration in stream-side or littoral vegetative cover M Escherichia coli NA Nonirrigated Crop Production Channelization Pasture Grazing Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010202 009 - 1000 NORTH FORK OBION RIVER Obion Weakley 14.61 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 009 - 1100 DRY CREEK Henry 6.3 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010202 009 - 1700 SPRING HILL CREEK Henry 11.6 Loss of biological integrity due to siltation M Other Anthropogenic Habitat Alterations M Upstream Impoundment Removal of Riparian Vegetation Stream is Category 5. (One or more uses impaired.)

TN08010202 009 - 1900 MAYO BRANCH Weakley 7.4 Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010202 014 - 0300 CLAYPIT CREEK Weakley 3.8 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Upstream Impoundment Stream is Category 5. (One or more uses impaired.)

TN08010202 014 - 0400 STRAWBERRY BRANCH Weakley 1.92 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Upstream Impoundment Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 014 - 0500 OWL BRANCH Weakley 2.73 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 024 - 0100 WOLF CREEK Obion 5.3 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 024 - 0200 WALNUT GROVE CREEK Obion 6.2 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

129 Final Version 2010 303(d) LIST (Obion River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010202 024 - 0300 TROUBLE CREEK Weakley 4.7 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 024 - 0400 JONES BRANCH Weakley 5.2 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 024 - 1000 RICHLAND CREEK Weakley Obion 12.2 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 025 - 1000 HARRIS FORK CREEK Obion 9.6 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Discharges from MS4 Area Channelization South Fulton area impacts.

Stream is Category 5. (One or more uses impaired.)

TN08010202 027 - 1000 RICHLAND CREEK Obion 11.2 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 028 - 1000 CLOVER CREEK Obion 11.7 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 029 - 1000 RUNNING REELFOOT BAYOU Obion Lake 23.8 Low Dissolved Oxygen M Loss of biological integrity due to siltation M Flow Alteration NA Nutrients M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Upstream Impoundment Landfill Two fully supporting tributaries, Paw Paw Creek and Rock Branch are reference streams for the West TN uplands. Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN08010202 036 - 0100 NORTH REELFOOT CREEK Obion 20.6 Escherichia coli H Physical Substrate Habitat Alterations M Alteration in stream-side or littoral vegetative cover M Nitrate+Nitrite M Phosphorus M Pasture Grazing Channelization Nonirrigated Crop Production Stream is Category 5 (one or more uses impaired).

130 Final Version 2010 303(d) LIST (Obion River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010202 036 - 0120 TULL CREEK Obion 1.1 Low Dissolved Oxygen M Habitat loss due to stream flow alteration NA Upstream Impoundment Randomly selected for Impounded Streams Study below Reelfoot Watershed Lake #14. Category 5, but 4c for flow alteration (impact not caused by a pollutant).

TN08010202 036 - 0160 TAYLOR CREEK Obion 10.5 Low Dissolved Oxygen M Habitat loss due to stream flow alteration NA Other Anthropogenic Habitat Alterations M Upstream Impoundment Channelization Randomly selected for Impounded Streams Study below Reelfoot Watershed Lake #7. Category 5, but is 4c for flow alteration (impact not caused by a pollutant).

TN08010202 036 - 0200 SOUTH REELFOOT CREEK Obion 13.7 Escherichia coli H Pasture Grazing Stream is Category 5 (one or more uses impaired).

TN08010202 036 - 1000 REELFOOT CREEK Obion 8.0 Loss of biological integrity due to siltation M Nutrients L Habitat loss due to stream flow alteration NA Escherichia coli NA Nonirrigated Crop Production Upstream Impoundment Channelization Pasture Grazing Channelization, agricultural runoff, erosion and the building of sedimentation dams have caused impacts. Category 5, but flow alteration is 4c (impact not caused by a pollutant).

EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010202 040 - 1000 BLUE BASIN, REELFOOT LAKE Obion Lake 10950.0 ac Loss of biological integrity due to siltation M Nutrients L Low dissolved oxygen L Habitat loss due to stream flow alteration NA Nonirrigated Crop Production Land Development Internal Nutrient Cycling Drainage/filling wetlands Blue Basin has been impacted by shoreline development, sedimentation, low DO, and the effects of accelerated eutrophication. Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN08010202 040 - 2000 BUCK BASIN, REELFOOT LAKE Obion 2900 ac Nutrients L Loss of biological integrity due to siltation M Noxious Aquatic Plants L Low dissolved oxygen L Nonirrigated Crop Production Internal Nutrient Cycling Buck Basin impacted by sedimentation, low DO, aquatic plants, and accelerated eutrophication.

Category 5. (One or more uses impaired.)

TN08010202 040 - 3000 UPPER BLUE BASIN, REELFOOT LAKE Obion 1650 ac Nutrients L Loss of biological integrity due to siltation M Noxious Aquatic Plants L Low DO L Nonirrigated Crop Production Internal Nutrient Cycling Upper Blue Basin impacted by sedimentation, low DO, aquatic plants, and the effects of accelerated eutrophication.

Category 5. (One or more uses impaired.)

131 Final Version 2010 303(d) LIST (Obion River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010202 040T - 0500 INDIAN CREEK Obion 11.5 Loss of biological integrity due to siltation M Flow Alteration NA Nonirrigated Crop Production Upstream Impoundment Sedimentation lake has altered stream flows. Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN08010202 048 - 0100 ZION CREEK Obion 11.8 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 048 - 1000 CLOVERDALE CREEK Obion Dyer 8.7 Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 054 - 1000 BIFFLE CREEK Dyer 7.8 Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 419 - 1000 HOOSIER CREEK Obion 10.3 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010202 500 - 1000 CYPRESS CREEK Obion Weakley 12.1 Phosphorus M Habitat loss due to alteration in stream-side or littoral vegetative cover M Physical Substrate Habitat Alterations M Land Application of Wastes Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

South Fork Obion River This basin contains the following USGS Hydrologic Unit Codes: 08010203 (South Fork Obion River and Rutherford Fork Obion River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010203 001 - 0900 CLEAR CREEK Carroll 3.6 Escherichia coli NA Municipal Point Source Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010203 001 - 0910 SPRING CREEK Carroll 7.63 Nitrate+Nitrite L Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli H Municipal Point Source Failing Collection System Channelization Land Development Stream is Category 5. (One or more uses impaired.)

TN08010203 001 - 1000 &

2000 SOUTH FORK OBION RIVER Obion Weakley Gibson 42.8 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 001 - 1600 UNNAMED TRIB TO SOUTH FORK OBION RIVER Gibson 8.8 Physical Substrate Habitat Alterations M Channelization Near Bradford. Stream is Category 5. (One or more uses impaired.)

132 Final Version 2010 303(d) LIST (South Fork Obion River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010203 007 - 2000 REEDY CREEK Carroll 10.99 Loss of biological integrity due to siltation M Physical Substrate Habitat Alteration M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010203 015 - 0100 TERRELL BRANCH Weakley 4.6 Loss of biological integrity due to siltation M Physical Substrate Habitat Alteration M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010203 015 - 0600 THOMPSON CREEK Weakley 6.2 Nitrate+Nitrite M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Flow Alteration NA Nonirrigated Crop Production Upstream Impoundment Channelization Below Garrett Lake impacted by flow alteration from the lake, plus channelization.

Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN08010203 015 - 0700 OLD TOWN CREEK Henry 5.35 Flow Alteration NA Upstream Impoundment Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN08010203 015 - 1300 ARNOLD BRANCH Weakley 4.8 Flow Alteration NA Upstream Impoundment Randomly-selected for Impounded Stream Study.

Category 5, but flow alteration is 4c (impact not caused by a pollutant).

TN08010203 015 - 1400 SUMMERS CREEK Weakley 3.7 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010203 015 - 1500 MORRIS BRANCH Weakley 4.2 Nutrients M Physical Substrate Habitat Alteration M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010203 015 - 1800 BUCKOR DITCH Weakley 6.2 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010203 015 - 2000 MIDDLE FORK OBION RIVER Weakley 6.40 Nitrate+Nitrite L Loss of biological integrity due to siltation L Municipal Point Source Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 015 - 3000 MIDDLE FORK OBION RIVER Weakley Henry 19.9 Nitrate+Nitrite L Loss of biological integrity due to siltation L Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 016 - 0200 COTTON CREEK Weakley 12.3 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

133 Final Version 2010 303(d) LIST (South Fork Obion River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010203 016 - 0400 BOAZ CREEK Weakley Henry 5.8 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 020 - 0100 CANE CREEK Obion Weakley 16.7 Physical Substrate Habitat Alterations M Discharges from MS4 area Stream is Category 5. (One or more uses impaired.)

TN08010203 032 - 1000 &

2000 RUTHERFORD FORK OBION RIVER Obion Gibson 29.9 Loss of biological integrity due to siltation L Physical Substrate Habitat Alterations L Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 032 - 1400 JOHNS CREEK Carroll 21.7 RDX L Hazardous Waste Stream is Category 5. (One or more uses impaired.)

TN08010203 032 - 1410 HALLS BRANCH Carroll 11.4 RDX L Hazardous Waste Stream is Category 5. (One or more uses impaired.)

TN08010203 032 - 1500 WOLF CREEK Gibson 21.6 RDX L Loss of biological integrity due to siltation M Hazardous Waste Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 032 - 1510 EAST FORK WOLF CREEK Gibson Carroll 8.2 RDX L Loss of biological integrity due to siltation M Hazardous Waste Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 032 - 1900 CAMP CREEK Gibson 11.8 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 032 - 2100 OWEN CREEK Gibson 5.8 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 032 - 2200 CUMMINGS CREEK Gibson 3.41 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010203 032 - 2300 EDMUNDSON CREEK Gibson 14.7 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

134 North Fork Forked Deer River This basin contains the following USGS Hydrologic Unit Codes: 08010204 (North and Middle Forks Forked Deer River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010204 001 - 1000 NORTH FORK FORKED DEER RIVER Gibson Dyer 8.34 Phosphorus L Loss of biological integrity due to siltation M Nonirrigated Crop Production Discharges from MS4 area Channelization Category 5. TMDLs needed.

TN08010204 003 - 0100 CAIN CREEK Dyer 2.62 Physical Substrate Habitat Alteration M Channelization Category 5. TMDL needed.

TN08010204 003 - 0200 LITTLE POND CREEK Crockett 9.3 Physical Substrate Habitat Alteration M Channelization Category 5. TMDL needed.

TN08010204 003 - 0300 TUCKER CREEK Crockett 8.74 Physical Substrate Habitat Alteration M Loss of biological integrity due to siltation M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 003 - 1000 POND CREEK Dyer Crockett 24.7 Low Dissolved Oxygen L Phosphorus L Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 004 - 0100 PARKER DITCH Dyer 9.58 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization Category 5. The stream is impaired for one or more uses.

TN08010204 004 - 0200 BETHEL BRANCH Dyer Gibson 30.4 Nitrate+Nitrite L Phosphorus L Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Pasture Grazing Channelization Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN08010204 004 - 0300 SQUIRT CREEK Gibson 5.94 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010204 004 - 0400 ELIZA CREEK Dyer 7.02 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010204 004 - 0500 NASH CREEK Dyer 11.06 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010204 004 - 1000 NORTH FORK FORKED DEER RIVER Dyer 9.34 Physical Substrate Habitat Alterations M Mercury L Channelization Atmospheric Deposition Category 5. Impaired for one or more uses.

TN08010204 004 - 2000 NORTH FORK FORKED DEER RIVER Gibson Dyer 7.06 Mercury L Atmospheric Deposition Category 5. Impaired for one or more uses.

135 Final Version 2010 303(d) LIST (North Fork Forked Deer River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010204 005 - 0100 ODELL CREEK Crockett 7.65 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 005 - 0200 RICE CREEK Crockett 5.12 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 005 - 0300 MILLER CREEK Dyer Crockett 9.92 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 005 - 1000 STOKES CREEK Dyer 8.24 Phosphorus L Low Dissolved Oxygen L Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 007 - 0100 BUCK CREEK Crockett Gibson 29.4 Phosphorus L Low Dissolved Oxygen L Physical Substrate Habitat Alterations M Municipal Point Source Nonirrigated Crop Production Channelization Category 5. The stream is impaired for one or more uses.

TN08010204 007 - 1000 MIDDLE FORK FORKED DEER RIVER Gibson Crockett 15.3 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 009 - 0100 SAND CREEK Crockett 14.29 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

136 Final Version 2010 303(d) LIST (North Fork Forked Deer River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010204 009 - 0200 UNNAMED TRIB TO CYPRESS CREEK Crockett 3.19 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010204 009 - 1000 CYPRESS CREEK Crockett 13.0 Phosphorus L Low Dissolved Oxygen L Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Escherichia coli H Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. The stream is impaired for one or more uses.

TN08010204 010 - 0100 BARNETT BRANCH Gibson 15.6 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Category 5. The stream is impaired for one or more uses.

TN08010204 010 - 0200 DUFFYS BRANCH Gibson Madison 6.4 Loss of biological integrity due to siltation M Nonirrigated Crop Production Category 5. The stream is impaired for one or more uses.

TN08010204 010 - 0300 DRY BRANCH Gibson Madison 9.7 Loss of biological integrity due to siltation M Nonirrigated Crop Production Category 5. The stream is impaired for one or more uses.

TN08010204 010 - 0400 CROOKED CREEK Madison 5.0 Physical Substrate Habitat Alterations H Loss of biological integrity due to siltation H Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 010 - 0500 POPLAR CREEK Madison 9.7 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Land Development Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 010 - 0600 JOHNSON CREEK Madison 11.0 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization Land Development This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 010 - 0700 DYER CREEK Madison 30.6 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli H Discharges from MS4 area Land Development Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 010 - 0800 MOIZE CREEK Madison 12.8 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli H Discharges from MS4 area Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 010 - 0900 DE LOACH CREEK Madison 13.4 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Discharges from MS4 area Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

137 Final Version 2010 303(d) LIST (North Fork Forked Deer River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010204 010 - 1000 MIDDLE FORK FORKED DEER RIVER Crockett Gibson 9.5 Escherichia coli NA Collection System Failure Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010204 010 - 1100 MATTHEWS CREEK Madison 16.1 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Land Development Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 010 - 1200 BEECH CREEK Madison Crockett 23.8 Physical Substrate Habitat Alterations M Escherichia coli M Nonirrigated Crop Production Channelization Pasture Grazing Category 5. TMDLs needed.

TN08010204 010 - 1300 WARREN DITCH Crockett 9.0 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 010 - 2000 MIDDLE FORK FORKED DEER RIVER Madison Crockett 8.5 Loss of biological integrity due to siltation M Escherichia coli M Discharges from MS4 Area Nonirrigated Crop Production Land Development Category 5. TMDLs needed.

TN08010204 013 - 1000 GILMES CREEK Madison 15.3 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010204 014 - 0100 DRY CREEK Madison Carroll 9.0 Physical Substrate Habitat Alterations M Escherichia coli NA Pasture Grazing Channelization Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 014 - 0500 CANE CREEK Henderson 17.8 Physical Substrate Habitat Alterations M Land Development Silviculture Stream is Category 5. (One or more uses impaired.)

TN08010204 014 - 0600 SPRING CREEK Henderson 19.2 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Pasture Grazing Channelization Stream is Category 5. (One or more uses impaired.)

TN08010204 014 - 0700 TYLER BRANCH Henderson 2.39 Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN08010204 014 - 0800 SIMMONS BRANCH Henderson 2.98 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

138 Final Version 2010 303(d) LIST (North Fork Forked Deer River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010204 014 - 0900 COURTNEY BRANCH Henderson 5.61 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN08010204 014 - 1300 EUBANKS BRANCH Madison 4.39 Flow Alteration NA Upstream Impoundment Category 4c. Impact not due to pollutant.

TN08010204 015 - 1000 TURKEY CREEK Madison Gibson 24.3 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Channelization Nonirrigated Crop Production Land Development Category 5. The stream is impaired for one or more uses.

TN08010204 016 - 1000 SUGAR CREEK Gibson Crockett 26.5 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Land Development Category 5. The stream is impaired for one or more uses.

TN08010204 017 - 0100 DAVIS CREEK Gibson 32.6 Nitrate+Nitrite L Phosphorus L Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 017 - 0110 REAGAN CREEK Gibson 13.3 Low Dissolved Oxygen L Physical Substrate Habitat Alterations L Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010204 017 - 1000 BUCK CREEK Gibson 39.8 Low Dissolved Oxygen L Phosphorus L Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source This stream is Category 5.

The stream is impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 020 - 0100 BUZZARD ROOST CREEK Gibson 5.28 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 020 - 0200 ROGERS BRANCH Gibson 4.59 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

139 Final Version 2010 303(d) LIST (North Fork Forked Deer River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010204 020 - 0300 UNNAMED TRIB TO NORTH FORK FORKED DEER RIVER Gibson 4.87 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 020 - 0500 BEE CREEK Gibson 2.64 Physical Substrate Habitat Alterations H Loss of biological integrity due to siltation H Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 020 - 0600 HOG CREEK Gibson 6.2 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 020 - 0700 WALLSMITH BRANCH Gibson 6.8 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 020 - 0800 PARKER BRANCH Gibson 12.0 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 020 - 0900 CAIN CREEK Gibson 27.1 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 020 - 1000 NORTH FORK FORKED DEER RIVER Gibson 10.9 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization Category 5. The stream is impaired for one or more uses.

TN08010204 020 - 2000 NORTH FORK FORKED DEER RIVER Gibson 8.2 Physical Substrate Habitat Alterations M Channelization Category 5. The stream is impaired for one or more uses.

TN08010204 020 - 3000 NORTH FORK FORKED DEER RIVER Gibson 9.7 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010204 021 - 0100 DRY CREEK Gibson 5.73 Physical Substrate Habitat Alterations M Channelization Category 5. The stream is impaired for one or more uses.

TN08010204 021 - 0200 COW CREEK Gibson 11.8 Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Channelization This stream is Category 5.

The stream is impaired for one or more uses.

140 Final Version 2010 303(d) LIST (North Fork Forked Deer River Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010204 021 - 1000 MUD CREEK Gibson 33.56 Physical Substrate Habitat Alterations M Channelization Category 5. The stream is impaired for one or more uses.

TN08010204 022 - 0100 HARRIS CREEK Dyer 11.6 Physical Substrate Habitat Alterations M Escherichia coli NA Pasture Grazing Channelization Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 022 - 0200 UNNAMED TRIB TO DOAKVILLE CREEK Dyer 2.68 Physical Substrate Habitat Alterations M Channelization Category 5.

TN08010204 022 - 1000 DOAKVILLE CREEK Dyer 9.5 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Low Dissolved Oxygen L Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 023 - 0200 JONES CREEK Dyer 21.05 Physical Substrate Habitat Alterations M Escherichia coli NA Channelization Undetermined Pathogen Source Category 5. Impaired, but EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 023 - 0210 LIGHT CREEK Dyer 30.91 Physical Substrate Habitat Alterations M Escherichia coli NA Channelization Pasture Grazing Category 5. Impaired, but EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 023 - 1000 LEWIS CREEK Dyer 46.3 Low Dissolved Oxygen L

Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Discharges from MS4 area Channelization Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010204 HUMBOLDT LK - 1000 HUMBOLDT LAKE Crockett 87 ac Nutrients L Nonirrigated Crop Production Pasture Grazing Category 5. The stream is impaired for one or more uses.

141 South Fork Forked Deer River This basin contains the following USGS Hydrologic Unit Codes: 08010205 (South Fork Forked Deer River) and 08010206 (Forked Deer River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010205 001 - 0200 MILL CREEK Lauderdale 27.2 Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli H Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. TMDLs needed.

TN08010205 001 - 0300 CHAMBERS BRANCH Lauderdale 8.7 Habitat loss due to alteration in stream-side or littoral vegetative cover M Nonirrigated Crop Production Channelization Category 5. TMDLs needed.

TN08010205 001 - 1000 SOUTH FORK FORKED DEER RIVER Lauderdale Dyer 15.6 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 003 - 1000 SOUTH FORK FORKED DEER RIVER Crockett Lauderdale 6.8 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 005 -0100 LITTLE NIXON CREEK Haywood 15.3 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Channelization Discharges from MS4 area Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 005 -0200 MERIDIAN CREEK Haywood 36.29 Low Dissolved Oxygen M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Category 5. TMDLs needed.

TN08010205 005 -0210 BRIAR CREEK Haywood 7.61 Physical Substrate Habitat Alterations M Channelization Category 5. TMDLs needed.

TN08010205 005 -0300 POND CREEK Haywood Lauderdale 45.2 Physical Substrate Habitat Alterations M Channelization Category 5. TMDL needed.

TN08010205 005 -0310 OTTER CREEK Lauderdale Haywood 15.31 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Channelization Category 5. The stream is impaired for one or more uses.

TN08010205 005 -0400 LOST CREEK Haywood Lauderdale 14.6 Physical Substrate Habitat Alterations M Channelization Category 5. TMDL needed.

142 Final Version 2010 303(d) LIST (South Fork Forked Deer River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010205 005 -1000 NIXON CREEK Haywood 20.4 Loss of biological integrity due to siltation M Phosphorus L Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Discharges from MS4 area Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 010 -0100 KAIL CREEK Crockett Haywood 27.4 Physical Substrate Habitat Alterations M Escherichia coli H Channelization Undetermined Pathogen Source Category 5. The stream is impaired for one or more uses.

TN08010205 010 -0200 JACOBS CREEK Haywood 25.9 Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Category 5. The stream is impaired for one or more uses.

TN08010205 010 - 1000 SOUTH FORK FORKED DEER RIVER Haywood Crockett 13.2 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 011 - 1000 MUD CREEK Haywood 42.9 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010205 011 - 0100 PEARSONS CREEK Crockett 13.9 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Category 5. TMDLs needed.

TN08010205 012 - 0400 SANDY CREEK Madison 4.3 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Discharges from MS4 area Channelization Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 012 - 0500 CENTRAL CREEK Madison 2.0 Physical Substrate Habitat Alterations M Escherichia coli NA Discharges from MS4 area Channelization Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 012 - 0600 ANDERSON BRANCH Madison 5.2 Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli NA Collection System Failure Discharges from MS4 Area Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 012 - 0700 BOND CREEK Madison 9.7 Habitat loss due to alteration in stream-side or littoral vegetative cover M Escherichia coli NA Discharges from MS4 area Streambank Modifications Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 012 - 0900 HICKS CREEK Madison 28.5 Loss of biological integrity due to siltation M Sand/Rock/Gravel Mining Stream is Category 5. (One or more uses impaired.)

143 Final Version 2010 303(d) LIST (South Fork Forked Deer River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010205 012 - 1000 SOUTH FORK FORKED DEER RIVER Crockett Madison 21.6 Phosphorus L Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Discharges from MS4 area Nonirrigated Crop Production Dredge Mining Sand/Rock/Gravel Mining Land Development Channelization Category 5. The stream is impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 012 - 1100 JOHNSON CREEK Madison 44.2 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010205 012 - 1200 CUB CREEK Madison 2.07 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Escherichia coli NA Animal Feeding Operations (NPS)

Pasture Grazing Channelization Category 4A. Impaired, but EPA has approved a pathogen TMDL that addresses the known pollutants.

TN08010205 012 - 1400 PANTHER CREEK Madison Heywood 21.1 Escherichia coli NA Package Plant Pasture Grazing Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010205 017 - 2000 MERIDIAN CREEK Madison 0.73 Flow Alteration NA Upstream Impoundment Category 4c. Impacts not caused by a pollutant.

TN08010205 023 - 0110 DRY BRANCH Chester 12.0 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Pasture Grazing Category 5. TMDLs needed.

TN08010205 028 - 0150 BROWN CREEK Madison 12.6 Loss of biological integrity due to siltation M Land Development Category 5. TMDL needed.

TN08010205 028 - 0600 UNNAMED TRIB TO THE NORTH FORK OF THE SOUTH FORK FORKED DEER RIVER Henderson 10.77 Habitat loss due to alteration in stream-side or littoral vegetative cover M Physical Substrate Habitat Alterations M Pasture Grazing Channelization Category 5. TMDL needed.

TN08010205 031 - 0100 LICK CREEK Crockett 6.6 Physical Substrate Habitat Alterations M Channelization Category 5. TMDL needed.

TN08010205 031 - 0200 BEAR CREEK Crockett 6.4 Physical Substrate Habitat Alterations M Channelization Category 5. TMDL needed.

144 Final Version 2010 303(d) LIST (South Fork Forked Deer River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010205 031 - 1000 BLACK CREEK Crockett 12.9 Nutrient Biological Indicators L Low Dissolved Oxygen L Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Nonirrigated Crop Production Channelization Category 5. Impaired, but EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010205 036 - 0100 TISDALE CREEK Lauderdale 12.14 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Nonirrigated Crop Production Category 5. TMDL needed.

TN08010205 036 - 0110 UNNAMED TRIB TO TISDALE CREEK Lauderdale 2.89 Habitat loss due to alteration in stream-side or littoral vegetative cover M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli H Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. TMDL needed.

TN08010205 036 - 0200 SUMROW CREEK Lauderdale 9.64 Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010205 036 - 1000 HALLS CREEK Lauderdale 15.77 Phosphorus L Habitat loss due to alteration in stream-side or littoral vegetative cover M Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Pathogen Source Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN08010206 001 - 1000 FORKED DEER RIVER Dyer Lauderdale 14.9 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Channelization This stream is Category 5.

The stream is impaired for one or more uses.

145 Hatchie River Basin This basin contains the following USGS Hydrologic Unit Codes: 08010207 (Upper Hatchie River) and 08010208 (Lower Hatchie River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010207 003 - 0100 COLONEL CREEK Hardeman 8.82 pH L Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010207 031 - 1000 CYPRESS CREEK Mc Nairy 16.7 Loss of biological integrity due to siltation M Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010207 044 - 1000 TUSCUMBIA RIVER Mc Nairy 8.9 Loss of biological integrity due to siltation M Sources Outside of State Channelization in Mississippi.

Stream is Category 5. (One or more uses impaired.) EPA or Mississippi should do TMDL.

TN08010207 072 - 0200 TALLEY SPRING BRANCH Hardeman 4.3 Habitat loss due to alteration in stream-side or littoral vegetative cover M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN08010208 001 -0200 COPPER SPRINGS CREEK Lauderdale 13.9 Low Dissolved Oxygen L Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010208 001 -0300 ALSTON CREEK Lauderdale 18.74 Low Dissolved Oxygen L Total Phosphorus L Escherichia coli H Municipal Point Source Stream is Category 5. (One or more uses impaired.)

TN08010208 001 -0400 UNNAMED TRIB TO HATCHIE RIVER Lauderdale 21.41 Low Dissolved Oxygen M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010208 001 -0800 WADE CREEK Hardeman Chester 26.9 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN08010208 001 -1100 CUB CREEK Hardeman 24.3 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010208 001 -1110 UNNAMED TRIB TO CUB CREEK Hardeman 4.16 Iron L Physical Substrate Habitat Alterations M Upstream Impoundment Impounded Stream Study Site.

Stream is Category 5. (One or more uses impaired.)

TN08010208 001 -1500 SHORT CREEK Hardeman 19.2 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010208 001 -1700 GAMBLE BRANCH Hardeman 6.0 Loss of biological integrity due to siltation NA Nonirrigated Crop Production Category 4a. EPA approved a siltation TMDL that addresses the known pollutants.

TN08010208 001 -1800 HICKORY CREEK Hardeman 25.5 Loss of biological integrity due to siltation M Physical substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010208 002 -1000 INDIAN CREEK Tipton 12.1 Physical substrate Habitat Alterations M Escherichia coli H Channelization Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010208 007 -0200 CATRON CREEK Fayette 17.2 Escherichia coli NA Pasture Grazing Permitted Confined Animal Feeding Operation Category 5. Approved pathogen TMDL addresses the known pollutants.

146 Final Version 2010 303(d) LIST (Hatchie River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010208 007 -1000 BIG MUDDY CREEK Haywood 7.5 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010208 009 -0100 LONDON CREEK Haywood 6.9 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010208 009 -0200 MORRIS BRANCH Haywood 2.44 Low Dissolved Oxygen L Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010208 009 - 0410 PRAIRIE CREEK Haywood 4.7 Low Dissolved Oxygen L Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010208 009 - 1000 POPLAR CREEK Haywood Fayette 17.8 Loss of biological integrity due to siltation NA Habitat loss due to alteration in stream-side or littoral vegetative cover M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Stream is Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN08010208 011 - 0100 LITTLE CREEK Fayette Hardeman 23.6 Nitrate+Nitrite L Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010208 011 - 2000 BEAR CREEK Fayette 7.9 Nitrate+Nitrite L Total Phosphorus L Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation NA Nonirrigated Crop Production Channelization Stream is Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN08010208 015 - 0100 OAK DAIN CREEK Hardeman 23.8 Flow Alterations NA Upstream Impoundment Impounded Streams Study.

Category 4C. (Impairment is not caused by a pollutant.)

TN08010208 017 - 0100 POTTERS CREEK Hardeman 10.2 Alteration to littoral or stream-side vegetation M Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN08010208 024 - 0210 HUDSON BRANCH Hardeman 2.52 Iron M Flow Alterations NA Upstream Impoundment Randomly selected for Impounded Streams Study.

Category 5, but 4C for flow alteration. (Impairment is not caused by a pollutant.)

TN08010208 027 - 2000 PINEY CREEK Chester 4.15 Temperature Alterations L Flow Alterations NA Upstream Impoundment Randomly selected for Impounded Streams Study.

Category 5, but 4C for flow alteration.

TN08010208 028 - 0100 UNNAMED TRIB TO GRAYS CREEK Hardeman 3.13 Flow Alterations NA Upstream Impoundment Randomly selected for Impounded Streams Study.

Category 4C. (Impairment is not caused by a pollutant.)

147 Final Version 2010 303(d) LIST (Hatchie River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010208 029 - 0100 DRY CREEK Hardeman 22.1 Loss of biological integrity due to siltation NA Physical substrate habitat alterations M Nonirrigated Crop Production Channelization Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN08010208 030 - 0100 TURKEY BRANCH Madison 5.6 Loss of biological integrity due to siltation NA Nonirrigated Crop Production Category 4a. EPA approved a siltation TMDL that addresses the known pollutants.

TN08010208 031 - 1000 SUGAR CREEK Haywood 10.5 Loss of biological integrity due to siltation NA Nonirrigated Crop Production Discharges from MS4 area Highway/Bridge Construction Brownsville area impacts.

Category 4a. EPA approved a siltation TMDL that addresses the known pollutants.

TN08010208 032 - 1000 CYPRESS CREEK Haywood 19.2 Loss of biological integrity due to siltation NA Low dissolved oxygen L Nonirrigated Crop Production Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN08010208 033 - 0100 CAMP CREEK Lauderdale Haywood 20.2 Low dissolved oxygen L Physical Substrate Habitat Alterations M Nonirrigated Crop Production Stream is Category 5. (One or more uses impaired.)

TN08010208 033 - 1000 LAGOON CREEK Lauderdale Haywood 19.3 Low dissolved oxygen L Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010208 034 - 0100 OLD CHANNEL OF NELSON CREEK Lauderdale 0.76 Copper M Nitrate+Nitrite M Escherichia coli NA Major Industrial Point Source Undetermined Fecal Source Extremely high nutrient levels.

Category 5. One or more uses impaired. EPA has approved pathogen and copper TMDLs, however, the Cu criteria established by the TMDL are still being violated.

TN08010208 034 - 0200 NELSON CREEK Lauderdale 10.6 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. One or more uses impaired.

TN08010208 034 - 0300 HYDE CREEK Lauderdale 5.7 Nitrate+Nitrite L Escherichia coli NA Loss of biological integrity due to siltation NA Physical Substrate Habitat Alteration M Major Industrial Point Source Collection System Failure Channelization Urbanized High Density Area Category 5. EPA approved pathogen and siltation TMDLs that address some of the known pollutants.

TN08010208 034 - 0310 UNNAMED TRIB TO HYDE CREEK Lauderdale 1.2 Nitrate+Nitrite L Major Industrial Point Source Extremely high nutrient levels.

Category 5. EPA has approved a copper TMDL for this segment.

TN08010208 034 - 1000 CANE CREEK Lauderdale 14.1 Nitrate+Nitrite L Physical Substrate Habitat Alterations M Major Industrial Point Source Channelization Stream is Category 5. EPA has approved a copper TMDL for this segment.

148 Final Version 2010 303(d) LIST (Hatchie River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010208 034 - 2000 CANE CREEK Lauderdale 4.5 Copper NA Nitrate+Nitrite L Total Phosphorus L Physical Substrate Habitat Alterations M Escherichia coli H Major Industrial Point Source Collection System Failure Channelization Extremely high nutrient levels.

Stream is Category 5. One or more uses impaired, however EPA has approved a copper TMDL that addresses some of the known pollutants.

TN08010208 034 - 3000 CANE CREEK Lauderdale 1.0 Nitrate+Nitrite L Physical Substrate Habitat Alterations M Escherichia coli H Major Industrial Point Source Collection System Failure Channelization Extremely high nutrient levels.

Category 5. One or more uses impaired. EPA approved a copper TMDL for this segment.

TN08010208 056 - 1000 FLAT CREEK Tipton 8.1 Total Phosphorus L Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Source Category 5. EPA approved pathogen and siltation TMDLs that address some of the known pollutants.

TN08010208 062 - 1000 JEFFERS CREEK Haywood Madison 10.8 Loss of biological integrity due to siltation NA Nonirrigated Crop Production Category 4a. EPA approved a siltation TMDL that addresses the known pollutants.

TN08010208 065 - 1000 MATHIS CREEK Tipton 11.3 Physical Substrate Habitat Alteration M Escherichia coli H Nonirrigated Crop Production Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010208 072 - 1000 RICHLAND CREEK Haywood Hardeman 11.0 Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations M Nonirrigated Crop Production Category 5. EPA approved a siltation TMDL that addresses some of the known pollutants.

TN08010208 073 - 1000 RICHLAND CREEK Tipton 11.0 Low Dissolved Oxygen L Total Phosphorus L Loss of biological integrity due to siltation NA Physical Substrate Habitat Alterations M Escherichia coli NA Nonirrigated Crop Production Channelization Undetermined Source Category 5. EPA approved pathogen and siltation TMDLs that address some of the known pollutants.

TN08010208 946 - 1000 LITTLE MUDDY CREEK Haywood 14.5 Low Dissolved Oxygen L Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010208 896 - 1000 TOWN CREEK Tipton 11.3 Low Dissolved Oxygen L Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010208 1866 - 1000 CARTER CREEK Haywood 6.4 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

149 Loosahatchie River Basin This basin contains the following USGS Hydrologic Unit Codes: 08010209 (Loosahatchie River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010209 001 - 0100 TODD BRANCH Shelby 4.9 Low Dissolved Oxygen L Physical substrate Habitat Alterations M Total Phosphorus L Escherichia coli NA Discharges from MS4 area Channelization Collection System Failure Category 5, impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010209 001 - 1000 LOOSAHATCHIE RIVER Shelby 7.8 Mercury L PCBs NA Dioxins NA Chlordane NA Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Total Phosphorus L Escherichia coli NA Atmospheric Deposition Discharges from MS4 area Contaminated Sediment Channelization Fishing advisory originally due to chlordane. Category 5.

EPA approved PCB, dioxin, chlordane and pathogen TMDLs that address some of the known pollutants. EPA should take the lead on TMDLS involving atmospheric deposition.

TN08010209 002 - 0100 UNNAMED TRIB TO LOOSAHATCHIE RIVER Shelby 4.95 Escherichia coli H Discharges from MS4 area Category 5. TMDL needed.

TN08010209 002 - 0200 ROCKY BRANCH Shelby 6.62 Escherichia coli H Discharges from MS4 area Category 5. TMDL needed.

TN08010209 002 - 0300 SCOTTS CREEK Shelby 7.2 Flow Alterations NA Upstream Impoundment Category 4C. Impact not caused by a pollutant.

TN08010209 002 - 0400 OLIVER CREEK Shelby 7.4 Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli M Discharges from MS4 area Land Development Category 5. TMDLs needed.

TN08010209 002 - 0500 BUCKHEAD CREEK Shelby 14.59 Total Phosphorus L Low Dissolved Oxygen L Loss of biological integrity due to siltation M Escherichia coli M Discharges from MS4 area Land Development Category 5. TMDLs needed.

TN08010209 002 - 0600 HOWARD CREEK Shelby 7.21 Total Phosphorus L Escherichia coli H Discharges from MS4 area Category 5. TMDLs needed.

150 Final Version 2010 303(d) LIST (Loosahatchie River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010209 002 - 1000 LOOSAHATCHIE RIVER Shelby 10.3 Mercury L Chlordane NA PCBs NA Dioxin NA Total Phosphorus L Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Atmospheric Deposition Contaminated Sediment Discharges from MS4 area Land Development Channelization Category 5. EPA approved PCB, dioxin, chlordane and pathogen TMDLs that address some of the known pollutants.

EPA should take the lead on TMDLS involving atmospheric deposition.

TN08010209 002 - 2000 LOOSAHATCHIE RIVER Shelby 8.2 Total Phosphorus L Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Escherichia coli NA Municipal Point Source Discharges from MS4 area Land Development Channelization Category 5. The stream is impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010209 003 - 0200 CYPRESS CREEK Shelby Fayette 13.67 Total Phosphorus L Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Channelization Category 5. Impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010209 003 - 1000 CLEAR CREEK Shelby 2.67 Total Phosphorus L Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Escherichia coli NA Pasture Grazing Channelization Category 5. Impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010209 004 - 0100 BLACK ANKLE CREEK Fayette 27.0 Low Dissolved Oxygen L Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli H Nonirrigated Crop Production Land Development Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010209 004 - 1000 LOOSAHATCHIE RIVER Shelby Fayette 10.0 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010209 007 - 1000 LOOSAHATCHIE RIVER Fayette 9.6 Physical Substrate Habitat Alterations M Escherichia coli H Channelization Undetermined Source Stream is Category 5. (One or more uses impaired.)

TN08010209 008 - 1000 TREADVILLE BOTTOM Fayette 32.16 Escherichia coli H Undetermined Source Stream is Category 5. (One or more uses impaired.)

151 Final Version 2010 303(d) LIST (Loosahatchie River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010209 010 - 1000 JONES CREEK Fayette 36.9 Physical Substrate Habitat Alteration M Loss of biological integrity due to siltation M Escherichia coli M Nonirrigated Crop Production Undetermined Source This stream is Category 5.

The stream is impaired for one or more uses.

TN08010209 011 - 1000 LOOSAHATCHIE RIVER Fayette 5.8 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010209 011 - 2000 LOOSAHATCHIE RIVER Fayette 14.1 Physical Substrate Habitat Alterations M Channelization Stream is Category 5. (One or more uses impaired.)

TN08010209 014 - 1000 LAUREL CREEK Fayette 38.2 Total Phosphorus L Low Dissolved Oxygen L Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Escherichia coli H Nonirrigated Crop Production Channelization Undetermined Source This stream is Category 5.

The stream is impaired for one or more uses.

TN08010209 015 - 1000 LITTLE CYPRESS CREEK Fayette 17.14 Total Phosphorus L Low Dissolved Oxygen L Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010209 016 - 0100 WEST BEAVER CREEK Shelby Tipton 30.95 Low Dissolved Oxygen L Total Phosphorus L Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010209 016 - 0200 MIDDLE BEAVER CREEK Tipton 65.37 Low Dissolved Oxygen L Total Phosphorus L Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Pasture Grazing Channelization This stream is Category 5.

The stream is impaired for one or more uses.

TN08010209 016 - 0210 KELLY CREEK Tipton 16.67 Escherichia coli H Pasture Grazing Category 5. The stream is impaired for one or more uses.

TN08010209 016 - 0400 EAST BEAVER CREEK Tipton Fayette 84.5 Low Dissolved Oxygen L Nitrate+Nitrite L Total Phosphorus L Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production This stream is Category 5.

The stream is impaired for one or more uses.

152 Final Version 2010 303(d) LIST (Loosahatchie River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010209 016 - 0410 BAXTER BOTTOM Tipton 37.99 Physical Substrate Habitat Alterations M Channelization Category 5. The stream is impaired for one or more uses.

TN08010209 016 - 1000 BEAVER CREEK Shelby 30.38 Total Phosphorus L Low Dissolved Oxygen M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Nonirrigated Crop Production Channelization Category 5. The stream is impaired for one or more uses.

TN08010209 021 - 0100 JAKES CREEK Shelby 22.8 Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli H Nonirrigated Crop Production Undetermined Source Category 5. (One or more uses impaired.)

TN08010209 021 - 0110 BEAR CREEK Shelby Tipton 14.5 Total Phosphorus L Low Dissolved Oxygen L Escherichia coli H Nonirrigated Crop Production Pasture Grazing Stream is Category 5. (One or more uses impaired.)

TN08010209 021 - 0200 ROYSTER CREEK Shelby Tipton 37.4 Total Phosphorus L Low Dissolved Oxygen M Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Escherichia coli H Nonirrigated Crop Production Channelization Pasture Grazing Category 5. The stream is impaired for one or more uses.

TN08010209 021 - 0300 NORTH FORK CREEK Shelby Tipton 37.6 Total Phosphorus L Low Dissolved Oxygen L Physical Substrate Habitat Alteration M Loss of biological integrity due to siltation M Escherichia coli H Nonirrigated Crop Production Channelization Discharges from MS4 area Category 5. The stream is impaired for one or more uses.

TN08010209 021 - 0600 CROOKED CREEK CANAL Shelby 31.21 Total Phosphorus L Low Dissolved Oxygen L Physical Substrate Habitat Alteration M Escherichia coli H Nonirrigated Crop Production Channelization Discharges from MS4 area Category 5. The stream is impaired for one or more uses.

TN08010209 021 - 1000 BIG CREEK Shelby 8.33 Low Dissolved Oxygen L Nitrate + Nitrite L Total Phosphorus L Physical Substrate Habitat Alteration M Loss of biological integrity due to siltation M Escherichia coli NA Discharges from MS4 area Municipal Point Source Channelization Category 5. The stream is impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

153 Final Version 2010 303(d) LIST (Loosahatchie River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010209 021 - 2000 BIG CREEK Shelby 6.25 Low Dissolved Oxygen L Total Phosphorus L Physical Substrate Habitat Alteration M Loss of biological integrity due to siltation M Escherichia coli NA Discharges from MS4 area Channelization Category 5. The stream is impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010209 021 - 3000 BIG CREEK Shelby Tipton 27.75 Total Phosphorus L Low Dissolved Oxygen L Physical Substrate Habitat Alteration M Loss of biological integrity due to siltation M Escherichia coli H Nonirrigated Crop Production Channelization Discharges from MS4 area This stream is Category 5.

The stream is impaired for one or more uses.

TN08010209 021 - 4000 BIG CREEK Tipton 35.1 Escherichia coli H Undetermined Source Category 5. The stream is impaired for one or more uses.

Wolf River Basin This basin contains the following USGS Hydrologic Unit Codes: 08010210 (Wolf River).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010210 001 - 0100 HARRINGTON CREEK Shelby 16.5 Arsenic M Phosphate L Low dissolved oxygen L Escherichia coli NA Discharges from MS4 area Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010210 001 - 0300 WORKHOUSE BAYOU Shelby 3.7 Habitat loss due to alteration in stream-side or littoral vegetative cover M Phosphate L Escherichia coli NA Discharges from MS4 area Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010210 001 - 1000 WOLF RIVER Shelby 12.8 Mercury L Lead M Chlordane NA PCBs NA Dioxin M Loss of biological integrity due to siltation M Escherichia coli NA Atmospheric Deposition Discharges from MS4 area RCRA Hazardous Waste Site Channelization Contaminated sediments Fishing advisory. Category 5.

EPA approved PCB, chlordane and pathogen TMDLs that address some of the known pollutants. EPA should take the lead on TMDLS involving atmospheric deposition.

154 Final Version 2010 303(d) LIST (Wolf River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010210 002 - 0100 SWEETBRIAR CREEK Shelby 2.5 Physical Substrate Habitat Alterations M Hydromodification Stream is Category 5. (One or more uses impaired.)

TN08010210 002 - 1000 WOLF RIVER Shelby 6.3 Mercury L Chlordane NA PCBs NA Dioxin M Lead M Loss of biological integrity due to siltation M Escherichia coli NA Atmospheric Deposition RCRA Hazardous Waste Site Contaminated Sediments Channelization Discharges from MS4 area Fishing advisory. Category 5.

EPA approved PCB, chlordane and pathogen TMDLs that address some of the known pollutants. EPA should take the lead on TMDLS involving atmospheric deposition.

TN08010210 002 - 2000 WOLF RIVER Shelby 3.8 Lead M Loss of biological integrity due to siltation M Escherichia coli NA RCRA Hazardous Waste Site Channelization Discharges from MS4 area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010210 003 - 0100 JOHNSON CREEK Shelby Fayette 10.4 Escherichia coli NA Pasture Grazing Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010210 003 - 1000 WOLF RIVER Shelby 9.7 Lead M RCRA Hazardous Waste Site Stream is Category 5. (One or more uses impaired.)

TN08010210 004 - 0100 HURRICANE CREEK Fayette 12.5 Escherichia coli NA Pasture Grazing Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010210 004 - 0400 UNNAMED TRIB TO WOLF RIVER Fayette 23.6 Escherichia coli NA Pasture Grazing Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010210 004 - 0500 RUSSELL CREEK Fayette 12.8 Escherichia coli NA Pasture Grazing Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010210 005 - 0100 TEAGUE BRANCH Fayette 17.0 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Pasture Grazing This stream is Category 5.

The stream is impaired for one or more uses.

TN08010210 005 - 0200 STOUT CREEK Fayette 6.7 Physical Substrate Habitat Alterations M Low dissolved oxygen L Pasture Grazing Channelization Stream is Category 5. (One or more uses impaired.)

TN08010210 005 - 1000 GRISSUM CREEK Fayette 17.9 Loss of biological integrity due to siltation M Low dissolved oxygen L Escherichia coli NA Pasture Grazing Channelization Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010210 009 - 0100 UNNAMED TRIB TO WOLF RIVER Fayette 2.44 Nitrates L Pasture Grazing Stream is Category 5. (One or more uses impaired.)

155 Final Version 2010 303(d) LIST (Wolf River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010210 009 - 0300 EARLY GROVE CREEK Fayette 2.5 Escherichia coli NA Pasture Grazing Sources Outside of State Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010210 019 - 0300 MOODY CREEK Hardeman 3.1 Flow Alteration NA Upstream Impoundment Impacted by poor quality releases from Indian Cr. Lake

  1. 8. Category 4c. Impact not caused by a pollutant.

TN08010210 020 - 0300 MCKINNIE CREEK Fayette Hardeman 35.1 Low Dissolved Oxygen M Escherichia coli NA Pasture Grazing Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN08010210 020 - 0310 MAY CREEK Fayette Hardeman 27.1 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010210 020 - 0400 NORTH FORK CREEK Fayette Hardeman 39.0 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010210 020 - 2000 NORTH FORK WOLF RIVER Fayette 10.79 Escherichia coli NA Pasture Grazing Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010210 021 - 0100 ALEXANDER CREEK Fayette 21.8 Low Dissolved Oxygen L Escherichia coli NA Pasture Grazing Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN08010210 021 - 1000 SHAWS CREEK Fayette 20.1 Lead M Low dissolved oxygen L Escherichia coli NA Undetermined Source Pasture Grazing Category 5. Approved pathogen TMDL addresses some of the known pollutants.

TN08010210 022 - 0100 UNNAMED TRIB TO GRAYS CREEK Shelby 8.4 Loss of biological integrity due to siltation M Physical Substrate Habitat Alteration M Phosphate M Low Dissolved Oxygen M Escherichia coli NA Discharges from MS4 area Category 5. Impaired, but EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010210 022 - 0300 MARYS CREEK Shelby 17.4 Loss of biological integrity due to siltation M Phosphate M Low dissolved oxygen M Escherichia coli NA Discharges from MS4 Area Upstream Impoundment Category 5. Impaired, but EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010210 022 - 0350 MARYS CREEK Shelby Fayette 2.5 Habitat loss due to stream flow alteration NA Escherichia coli NA Upstream Impoundment Pasture Grazing Marys Creek impacted below Herb Parsons Lake. Category 4A. EPA approved a pathogen TMDL that addresses the known pollutant. Flow alteration is 4c.

156 Final Version 2010 303(d) LIST (Wolf River Basin cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010210 022 - 1000 GRAYS CREEK Shelby Fayette 15.8 Arsenic M Copper M Lead M Phosphate M Physical Substrate Habitat Alterations M Loss of biological integrity due to siltation M Discharges from MS4 Area Nonirrigated Crop Production Channelization Stream is Category 5. (One or more uses impaired.)

TN08010210 023 - 0100 UNNAMED TRIB TO FLETCHER CREEK Shelby 23.1 Escherichia coli NA Discharges from MS4 area Category 4a. EPA approved a pathogen TMDL that addresses the known pollutant.

TN08010210 023 - 0200 UNNAMED TRIB TO FLETCHER CREEK Shelby 6.5 Low Dissolved Oxygen L Phosphate L Escherichia coli NA Discharges from MS4 area Pasture Grazing Livestock Feeding Operations Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010210 023 - 1000 FLETCHER CREEK Shelby 10.7 Arsenic M Lead M Low Dissolved Oxygen L Phosphate L Physical Substrate Habitat Alterations M Escherichia coli NA Pasture Grazing Discharges from MS4 area Channelization Category 5. The stream is impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010210 032 - 1000 CYPRESS CREEK Shelby 8.6 Aldrin L Dieldrin L Endrin L DDT L Chlordane L Lead M Low Dissolved Oxygen M Phosphorus M Physical Substrate Habitat Alterations M Escherichia coli NA Contaminated Sediment Discharges from MS4 area Channelization Some sections of Cypress Creek concreted. Category 5.

Impaired, but EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010210 032 - 2000 CYPRESS CREEK Shelby 5.0 Low Dissolved Oxygen M Phosphorus M Physical Substrate Habitat Alterations M Escherichia coli NA Discharges from MS4 area Channelization Most of upper Cypress Creek concreted. Category 5.

Impaired, but EPA approved a pathogen TMDL that addresses some of the known pollutants.

157 Nonconnah Creek Basin This basin contains the following USGS Hydrologic Unit Codes: 08010211 (Nonconnah Creek).

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010211 001 - 0100 HORN LAKE CUTOFF Shelby 16.4 Low Dissolved Oxygen L Total Phosphorus L Loss of biological integrity due to siltation M Arsenic M Escherichia coli H Discharges from MS4 area This stream is Category 5.

The stream is impaired for one or more uses.

TN08010211 001 - 1000 HORN LAKE CREEK Shelby 10.3 Low Dissolved Oxygen L Loss of biological integrity due to siltation M Escherichia coli H Discharges from MS4 area This stream is Category 5.

The stream is impaired for one or more uses.

TN08010211 001 - 2000 HORN LAKE CREEK Shelby 5.2 Low Dissolved Oxygen L Loss of biological integrity due to siltation M Arsenic M Escherichia coli H Sources Outside of State Land Development Category 5. TMDLs for pollution sources outside of Tennessee should be done by Mississippi or EPA..

TN08010211 007 - 1000 CYPRESS CREEK Shelby 18.2 Low Dissolved Oxygen L Total Phosphorus L Arsenic M Escherichia coli NA Discharges from MS4 area Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

TN08010211 00711- 0200 CANE CREEK Shelby 7.2 Low Dissolved Oxygen L Total Phosphorus L Physical Substrate Habitat Alteration M Escherichia coli NA Discharges from MS4 area Channelization Collection System Failure Category 5. Impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010211 00711- 0300 BLACK BAYOU Shelby 7.9 Phosphate L Physical Substrate Habitat Alteration M Escherichia coli NA Discharges from MS4 area Channelization Category 5. Impaired, but EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010211 00711- 0400 TENMILE CREEK Shelby 13.3 Low Dissolved Oxygen L Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli NA Discharges from MS4 area Category 5. Impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010211 00711- 0500 HURRICANE CREEK Shelby 13.3 Low Dissolved Oxygen L Total Phosphorus L Other anthropogenic substrate alterations M Escherichia coli NA Discharges from MS4 area Industrial Stormwater Discharge Channelization Category 5. Impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010211 00711- 0600 DAYS CREEK Shelby 10.6 Total Phosphorus L Other anthropogenic substrate alterations M Escherichia coli NA Discharges from MS4 area Channelization Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

158 Final Version 2010 303(d) LIST (Nonconnah Creek Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010211 00711-1000 NONCONNAH CREEK Shelby 3.2 PCBs H Dioxins M Chlordane M Total Phosphorus M Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Low Dissolved Oxygen L Escherichia coli NA Discharges from MS4 area Contaminated Sediment Channelization Fishing advisory. This stream is Category 5. The stream is impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants in this stream.

TN08010211 00711-2000 NONCONNAH CREEK Shelby 4.86 Total Phosphorus L Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Discharges from MS4 area Channelization This stream is Category 5.

The stream is impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010211 00711-3000 NONCONNAH CREEK Shelby 4.1 Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli NA Discharges from MS4 area Channelization Category 5. Impaired for one or more uses, however EPA has approved a pathogen TMDL that addresses some of the known pollutants.

TN08010211 00720- 0100 UNNAMED TRIB TO NONCONNAH CREEK Shelby 3.91 Total Phosphorus L Loss of biological integrity due to siltation M Other Anthropogenic Habitat Alterations M Escherichia coli M Discharges from MS4 area Category 5. TMDLs needed.

TN08010211 00720- 0200 UNNAMED TRIB TO NONCONNAH CREEK Shelby 4.02 Escherichia coli M Discharges from MS4 area Category 5. TMDLs needed.

TN08010211 00720- 0300 UNNAMED TRIB TO NONCONNAH CREEK Shelby 3.09 Total Phosphorus L Loss of biological integrity due to siltation M Specialty Crop Production This stream is Category 5.

TN08010211 00720- 0400 UNNAMED TRIB TO NONCONNAH CREEK Shelby 10.07 Total Phosphorus M Loss of biological integrity due to siltation M Escherichia coli M Sources Outside State Borders Category 5. TMDLs needed.

159 Final Version 2010 303(d) LIST (Nonconnah Creek Watershed cont.)

Waterbody ID Impacted Waterbody County Miles/Acres Impaired CAUSE / TMDL Priority Pollutant Source COMMENTS TN08010211 00720- 0410 UNNAMED TRIB TO THE UNNAMED TRIB TO NONCONNAH CREEK Shelby 2.53 Low Dissolved Oxygen L Total Phosphorus L Loss of biological integrity due to siltation M Escherichia coli M Pasture Grazing Sources Outside State Borders Category 5. TMDLs needed.

TN08010211 00720- 0500 UNNAMED TRIB TO NONCONNAH CREEK Shelby 8.93 Low Dissolved Oxygen L Total Phosphorus L Escherichia coli M Discharges from MS4 area Category 5. TMDLs needed.

TN08010211 00720- 1000 NONCONNAH CREEK Shelby 8.3 Total Phosphorus L Loss of biological integrity due to siltation M Physical Substrate Habitat Alterations M Escherichia coli M Discharges from MS4 area Channelization Category 5. TMDLs needed.

TN08010211 00720- 2000 NONCONNAH CREEK Shelby 6.2 Loss of biological integrity due to siltation L Physical Substrate Habitat Alterations M Escherichia coli M Discharges from MS4 area Land Development Channelization Category 5. TMDLs needed.

TN08010211 00720- 3000 NONCONNAH CREEK Shelby Fayette 6.5 Total Phosphorus L Physical Substrate Habitat Alterations M Discharges from MS4 area Nonirrigated Crop Production Channelization Category 5. TMDLs needed.

TN08010211 176 - 1000 JOHN'S CREEK Shelby 13.7 Total Phosphorus L Loss of biological integrity due to siltation M Other Anthropogenic Habitat Alterations M Escherichia coli NA Discharges from MS4 area Channelization Collection System Failure Category 5. EPA approved a pathogen TMDL that addresses some of the known pollutants.

160 APPENDIX A: Streams (or pollutants) on the 2008 303 (d) List Proposed For Delisting in 2010 For Reasons Related to Water Quality Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Reason For Delisting TN03150101 012 - 0300 BALL PLAY CREEK Polk 7.44 Siltation Pasture Grazing This stream was previously listed on the basis of a biological survey performed by the Conasauga Alliance which found that the stream did not meet Tennessees biological integrity standard. In 2006, TDEC resurveyed this stream and documented 10 EPT families, 4 intolerant, 22 total families for a biorecon score of 13. The habitat score at this site was 136 and didnt indicate that silt was a current problem. The stream had twice as many EPT and total families in 2006 than it had in the previous survey. The stream will remain listed for pathogens.

TN05130107 001 - 0100 UNNAMED TRIB TO COLLINS RIVER Warren 2.42 Siltation Undetermined Source During the 1990s, this stream was considered impacted by industrial discharges. However, the company is out of business and no longer discharging. The assessment pollutant was changed to siltation following a biological survey in 2003.

However, the stream was revisited in 2007 and found to be dry.

We now believe that due to the very small size of the stream (first order), we were incorrect to have compared its biology to the reference database, which is composed of larger streams.

TN05130107 002 - 0100 GATH BRANCH Warren 2.9 Riparian Loss Specialty Crop Production Pasture Grazing This stream was originally listed on the basis of a site visit conducted in the 1990s. Every since then, whenever the stream was revisited, its been dry. It is now believed that the appearance of impacts previously noted were due to sustained dryness rather than pollution.

TN05130107 002 - 0300 UNNAMED TRIB TO MOUNTAIN CREEK Warren 1.9 Siltation Riparian Loss Pasture Grazing This stream was originally listed on the basis of a site visit conducted in the 1990s. Every since then, whenever the stream was revisited, its been dry. It is now believed that the appearance of impacts previously noted were due to sustained dryness rather than pollution.

TN05130107 006 - 0310 MUD CREEK Coffee 14.0 Siltation Riparian Loss Pasture Grazing Nonirrigated Crop Production This stream was listed on the basis of biological surveys conducted in 1998 and 2003. It was scheduled for TMDL monitoring in 2007-2008, but was dry for seven consecutive months. It is now believed the previous appearance of impacts were due to periodic dryness.

TN05130107 006 - 0500 DOG BRANCH Warren 9.2 Siltation Riparian Loss Pasture Grazing This stream was listed on the basis of biological surveys conducted in 1998 and 2003. It was scheduled for TMDL monitoring in 2007-2008, but was dry for seven consecutive months. It is now believed the previous appearance of impacts were due to periodic dryness.

161 APPENDIX A (cont.)

Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Reason For Delisting TN05130108 045 - 3000 FALLING WATER RIVER Putnam 11.2 Nutrients Low Dissolved Oxygen Municipal Point Source This stream was originally listed on the basis of a 1993 survey.

In both 2002 and 2007, the department repeated biological surveys at mile 38.3 (Adams Acres Road). Both times, the stream passed biorecon goals. Dissolved oxygen levels were fine and excessive algae was not present.

TN05130108 033 - 0210 LITTLE BEAVERDAM CREEK Bledsoe 6.9 Siltation Pasture Grazing This stream was previously listed on the basis of a biological survey performed in the 1990s. In 2006, TDEC resurveyed this stream and documented 12 EPT families, 7 intolerant, 19 total families for a biorecon score of 15. The habitat score at this site was 181 and didnt indicate that silt was a current problem.

In 2009, a SQSH sample was collected which scored 36. It appears the stream has improved.

TN05130202 314 - 0200 MURPHY ROAD BRANCH Davidson 1.5 Escherichia coli Discharges from MS4 area This small, often dry, urban stream was assessed as impaired following a 1997 fecal coliform survey by the City of Nashville.

A follow-up 2003-2004 survey was inconclusive as the stream could not be sampled very often due to dryness. Metro Water Services Departments MS4 program collected a set of five E.

coli samples very quarter from 2007 to 2009. One out of 35 individual observations was over 941 cfu. The quarterly geometric means at this station were 17, 52, 91, 21, 41, 119, and 70 cfu.

TN05130203 001 - 0150 MCCRORY CREEK Davidson 10.7 Escherichia coli Discharges from MS4 Area This section of McCrory Creek is upstream of the historical collection system overflow points. 2008-2009 Metro pathogen data from a station at mile 3.3 (Elm Hill Pike) indicates that the pathogen standard is generally being met. Zero out of 25 E.

coli observations were over 941 cfu. August 2008 geo mean of five E. coli observations = 78.3 cfu. November 2008 geo mean of five E. coli observations = 104.2 cfu. February 2009 geo mean of five E. coli observations = 21.8 cfu. May 2009 geo mean of five E. coli observations = 86.2 cfu. August 2009 geo mean of five E. coli observations = 167.8 cfu. It will need to remain listed for nitrate+nitrite and riparian vegetation loss.

TN05130203 018 - 0210 CHRISTMAS CREEK Rutherford 12.3 Siltation Pasture Grazing Christmas Creek was listed on the basis of two failed biological studies done during the 2000 Probabilistic Study of Subecoregion 71i. In 2007, TDEC staff performed a biorecon at mile 0.8 (d/s Crescent Road). This survey documented 9 EPT families, 4 intolerant, and 33 total families for a perfect score of

15. Habitat scored 118, an acceptable score in this subecoregion. The stream has improved biologically, but will need to remain listed for pathogens.

162 APPENDIX A (cont.)

Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Reason For Delisting TN05130203 018 - 5000 WEST FORK STONES RIVER Rutherford 5.0 Siltation H

Land Development Pasture Grazing In 2007, TDEC staff performed a biorecon at mile 0.8 (d/s Barfield Road). This survey documented 11 EPT families, 7 intolerant, and 33 total families for a perfect score of 15.

Habitat scored 135, a good score in this subecoregion. The stream has improved biologically.

TN05130203 021 - 0100 HURRICANE CREEK Rutherford 12.06 Siltation Pasture Grazing Hurricane Creek was listed on the basis of two failed biological studies done during the 2000 Probabilistic Study of Subecoregion 71i. In 2007, TDEC staff performed a biorecon at mile 0.8 (u/s Cobbs Road). This survey documented 9 EPT families, 6 intolerant, and 23 total families for a perfect score of

15. Habitat scored 125, an acceptable score in this subecoregion. The stream has improved biologically.

TN05130203 021 - 0320 HENRY CREEK Rutherford 4.2 Siltation Pasture Grazing Henry Creek was listed on the basis of two failed biological studies done during the 2000 Probabilistic Study of Subecoregion 71i. In 2007, TDEC staff performed a biorecon at mile 0.8 (u/s Christiana Road). This survey documented 5 EPT families, 4 intolerant, and 11 total families for a score of 13.

Habitat scored 108, an acceptable score in this subecoregion, especially for a small stream like Henry Creek. The stream has improved biologically.

TN05130203 023 -0300 DRY BRANCH Rutherford 1.6 Siltation Pasture Grazing Land Development Dry Branch was originally listed on the basis of a 1996 biological survey. However, the stream has passed the last two surveys in 2002 and 2007. In 2002, TDEC staff performed a biorecon at mile 1.1 (Compton Road). This survey documented 5 EPT families, 3 intolerant, and 14 total families for a score of 11, which is passing. Habitat scored 110, an acceptable score in this subecoregion, In 2007 TDEC performed another biorecon at the same location. It documented 5 EPT families, with 3 intolerant and 19 total families, for a perfect score of 15. The habitat score was excellent at 148. It appears this stream has improved.

TN05130203 026 -0200 MCKNIGHT BRANCH Rutherford Cannon 18.8 Riparian Loss Pasture Grazing McKnight Branch was listed on the basis of two failed biological studies done during the 2000 Probabilistic Study of Subecoregion 71i. In 2007, TDEC staff performed a biorecon at mile 3.0 (u/s Trimble Road). This survey documented 8 EPT families,54 intolerant, and 25 total families for a perfect score of

15. Habitat scored 130, a good score in this subecoregion.

TN05130203 032 - 0100 UNNAMED TRIB TO FALL CREEK Wilson 3.0 Riparian Loss Siltation Pasture Grazing The last few times this stream has been visited, it was found to be dry. It is now believed that the previous appearance of impacts were due to periodic low water levels rather than being due to pollution.

163 APPENDIX A (cont.)

Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Reason For Delisting TN05130204 006 -0500 TIDWELL BRANCH Williamso n

1.1 Siltation Highways, Roads, Bridge Construction Tidwell Branch was impacted by poorly controlled runoff from the construction of SR 840. In 2006, TDEC staff performed a biorecon at mile 0.1 (Liberty Road). This survey documented 13 EPT families, 9 intolerant, and 20 total families for the excellent biorecon score of 15. Habitat scored 160 which is also a great score in this subecoregion.

TN05130204 006 -0710 RIALS BRANCH Dickson Hickman 1.9 Siltation Highways, Roads, Bridge Construction Rials Branch was impacted by poorly controlled runoff from the construction of SR 840. In 2006, TDEC staff performed a biorecon at mile 0.2 (Spencer Road). This survey documented 11 EPT families, 7 intolerant, and 20 total families for the excellent biorecon score of 15. Habitat scored 139 which is also a good score in this subecoregion. It appears that the stream has healed from the previous impacts.

TN05130204 006 -0800 PARKERS CREEK Dickson 4.1 Habitat alterations Siltation Highways, Roads, Bridge Construction Pasture Grazing Parkers Creek was impacted by poorly controlled runoff from the construction of SR 840. In 2006, TDEC staff performed a biorecon at mile 0.5 (Old Spencer Mill Road). This survey documented 13 EPT families, 8 intolerant, and 31 total families for the excellent biorecon score of 15. Habitat scored 153 which is also a good score in this subecoregion. It appears that the stream has healed from the previous impacts.

TN05130204 006 -0900 GOSLIN BRANCH Dickson Hickman 4.3 Siltation Highways, Roads, Bridge Construction Goslin Branch was impacted by poorly controlled runoff from the construction of SR 840. In 2006, TDEC staff performed a biorecon at mile 0.7 (Spicer Road). This survey documented 12 EPT families, 9 intolerant, and 24 total families for the excellent biorecon score of 15. Habitat scored 139 which is also a good score in this subecoregion. It appears that the stream has healed from the previous impacts.

TN05130204 006 -1220 JORDON HOLLOW CREEK Dickson 2.4 Siltation Highways, Roads, Bridge Construction Jordon Hollow Creek was impacted by poorly controlled runoff from the construction of SR 840. In 2006, TDEC staff performed a biorecon at mile 0.7 (Spicer Road). This survey documented 9 EPT families, 5 intolerant, and 20 total families for an acceptable biorecon score of 11. Habitat scored 141 which is also a good score in this subecoregion. It appears that the stream has healed from the previous impacts.

TN05130204 009 - 1100 BEECH CREEK Davidson 3.6 Nutrients Pasture Grazing Discharges from MS4 area This stream was listed as impacted by nutrients on the basis of a biological survey done in 1997. During this survey, it was observed that algae levels appeared excessive. In 2007 TDEC established a chemical monitoring station at mile 0.7 (Newsome Station Road). Nutrient concentrations were low and algae was less evident than before. The stream will need to remain listed for siltation and habitat alteration.

164 APPENDIX A (cont.)

Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Reason For Delisting TN05130204 009 - 1211 FLATROCK BRANCH Cheatham Williamso n

3.5 Nutrients Municipal Point Source Flatrock Branch was considered impacted by excessive nutrients discharged at Fairview STP. Following a significant change in the operation of the plant, three consecutive SQSH surveys conducted by a consultant passed Tennessees regionally based biocriteria. The stream has clearly improved.

TN05130204 013 - 0730 WEST PRONG MURFREES FORK Williamso n

6.0 Low dissolved oxygen Pasture Grazing This stream was listed as impacted on the basis of a biological survey done in 1997. However, during the last two sampling cycles, this stream has generated passing scores on biological surveys. In both 2001 and 2006, the stream scored 13, a good score, on biorecons at mile 0.3 (Thompson Station Road). The stream will need to remain listed for E. coli.

TN05130204 013 - 0750 MURFREES FORK Williamso n

18.4 Siltation Pasture Grazing This stream was listed as impacted on the basis of a biological survey done in 1997. However, during the last two sampling cycles, this stream has generated passing scores on biological surveys. In 2006 and 2008, the stream scored 11 and 13, both passing scores, on biorecons conducted at two different locations. The stream will need to remain listed for E. coli.

TN05130204 013 - 1000 WEST HARPETH RIVER Williamso n

13.4 Low DO Siltation Pasture Grazing This stream was originally listed on the basis of a biological survey done in 1997. However, during the last two sampling cycles, this stream has passing scores on biological surveys. In both 2002 and 2006, the stream scored 15, excellent scores, on biorecons conducted at mile 0.3 (Del Rio Pike).

TN05130204 013 - 3000 WEST HARPETH RIVER Williamso n

7.4 Riparian Loss Physical substrate habitat alterations Siltation Pasture Grazing Highways, Roads, Bridge Construction This stream was originally considered as an ecoregion reference stream, but was later listed on the basis of a biological survey done in 1997. However, during the last two sampling cycles, this stream has passing scores on biological surveys. In both 2001 and 2006, the stream scored 15, excellent scores, on biorecons conducted at mile 22.4 (Critz Lane). Habitat scored 125 and 109, acceptable scores in this region.

TN05130204 016 - 0900 STARNS CREEK Williamso n

9.96 Riparian Loss Siltation Pasture Grazing This stream was originally listed on the basis of a biological survey done in 1997. However, during the last two sampling cycles, this stream has passing scores on biological surveys. In both 2002 and 2006, the stream scored 11, both passing scores, on biorecons conducted at mile 0.6 (Arno Road).

Habitat scores were 114 and 119, respectively.

165 APPENDIX A (cont.)

Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Reason For Delisting TN06010102 012 - 0700 DRY CREEK Sullivan 1.01 Riparian Loss Siltation Animal Feeding Operations (NPS)

This stream was previously listed on the basis of biological surveys performed in the 2003. In 2008, TDEC resurveyed this stream at mile 1.0 (Mt. Holston Road) and documented 14 EPT genera and 39 total genera for a TMI score of 34. The habitat score at this site was 155 and didnt indicate that habitat was a current problem. It appears the stream has improved due to BMP implementation, but will need to remain listed for E. coli.

TN06010102 012 - 0800 INDIAN CREEK Sullivan 1.86 Polycyclic Aromatic Hydrocarbons (PAHs)

Other Spill Related Impacts This diesel spill into Woods Branch, a trib to Indian Creek happened nearly ten years ago. Due to the cleanup efforts and time, the effects of the spill can no longer be detected.

However, it will need to remain listed for riparian alterations.

TN06010102 012 - 0810 BIG ARM BRANCH Sullivan 5.77 Escherichia coli On-site Treatment Systems (Septic Tanks)

This stream was previously listed on the basis of pathogen monitoring performed in the 2003. In 2007-2008, TDEC resurveyed this stream at mile 0.5 (Bunker Hill Road). Only one out of 9 E. coli observations was elevated, and that one was following a rain event. It appears the stream has improved, but will need to remain listed for siltation and habitat alteration.

TN06010102 012 - 0820 WOODS BRANCH Sullivan 3.05 Polycyclic Aromatic Hydrocarbons (PAHs)

Other Spill Related Impacts This diesel spill into Woods Branch happened nearly ten years ago. Due to the cleanup efforts and time, the effects of the spill can no longer be detected. However, Woods Branch will need to remain listed for riparian alterations, siltation, and E. coli.

TN06010102 237 - 1000 MUDDY CREEK Sullivan 12.3 Siltation Riparian Loss Discharges from MS4 Area This stream was previously listed on the basis of biological surveys performed in the 1998. In 2008, TDEC resurveyed this stream at mile 0.7 (Spangler Road) and documented 8 EPT genera and 14 total genera for a TMI score of 36. The habitat score at this site was 131 and didnt indicate that habitat was a current problem. Muddy Creek also passed two biological surveys in 2003. It appears the stream has improved, but will need to remain listed for E. coli TN06010103 013 - 0300 HAMPTON CREEK Carter 6.2 Physical Substrate Habitat Alterations Channelization Hampton Creek was listed as impacted after a section of it was channelized an activity that took place without proper authorization. In the time that has passed, the stream has healed and the latest monitoring results have looked better. In 2006 TDEC collected a SQSH sample at mile 0.1 (off Hampton Creek Road). The sample had 18 EPT genera and 42 total genera, with a calculated Index score of 34. The habitat score was 168, an excellent score.

166 APPENDIX A (cont.)

Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Reason For Delisting TN06010103 034 - 0310 GOOSE CREEK Johnson 15.4 Riparian loss Land Development When biological test were done on this stream during the 2003 sampling cycle, Goose Creek performed poorly. In 2006, TDEC staff collected a SQSH at mile 0.1 (near mouth). The survey documented 13 EPT genera and 36 total genera for an Index score of 36. The habitat score was 143. It appears this stream has improved.

TN06010103 037 - 0400 CAMPBELL CREEK Johnson 10.8 Escherichia coli Septic Tanks Pasture Grazing During previous monitoring cycles, E. coli levels had been elevated. In the latest monitoring cycle, we found that to no longer be true. In 2006-2007, TDEC monitored a chemical station at mile 0.4 (Pandora-Campbell Road) on Campbell Creek. None of the 19 E. coli observations were over the single sample max of 941 cfu. The geo mean of five observations in April-May, 2007 was 5.8 cfu.

TN06010201 013 - 1000 POND CREEK Loudon Monroe 13.57 Nitrates Physical Substrate Habitat Alteration Pasture Grazing This stream has been considered impacted by agricultural activities, but has looked better, perhaps improved by intensive BMP implementation. In 2001, a TDEC SQSH station at mile 2.3 (Bradshaw Road) score 42 on the TMI index (32 is passing). Habitat was excellent and scored 173. At the time, that high score was not used to delist the stream because it was feared that the result was not representative of the rest of lower Pond Creek. In 2006, both TVA and TDEC performed biological surveys at the same location. TVAs biorecon scored 15 with 12 EPT families, 6 intolerant, and 28 total families.

TDECs SQSH scored 36 with 7 EPT genera and 23 total genera. Habitat was measured at 156. Pond Creek will need to remain listed for E. coli.

TN06010201 015 - 1000 SWEETWATER CREEK Loudon Monroe 7.75 Nitrates Siltation Pasture Grazing Land Development Animal Feeding Operation (NPS)

This stream has been considered impacted by agricultural activities and the town of Sweetwater, which is upstream.

However, it looked better in the latest round of sampling, perhaps improved by BMP implementation. In 2006, both TVA and TDEC performed biological surveys at the same location, mile 3.2 (Roberson Spring Branch). TVAs biorecon scored 9 with 7 EPT families, 1 intolerant, and 25 total families, not a particularly good score. However, TDECs SQSH scored 36 with 7 EPT genera and 27 total genera. Habitat was measured at 135, an acceptable score in this subecoregion.

Because of this good biological score at the lower station, it was decide to delist the most downstream section for everything except pathogens. The upper section will remain listed also.

167 APPENDIX A (cont.)

Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Reason For Delisting TN06010201 022 - 1000 GALLAGHER CREEK Blount 13.2 Siltation Pasture Grazing This stream was originally listed on the basis of a TVA biological survey. In 2003, a TDEC SQSH scored 36, a passing score. In 2007, both TVA and TDEC performed biological surveys at the same location, mile 2.6 (Unitia Road, Friendsville). TVAs biorecon scored 13 with 11 EPT families, 3 intolerant, and 23 total families. TDECs SQSH again scored 36 with 8 EPT genera and 20 total genera. Habitat was measured at 130, an acceptable score in this subecoregion.

Because of these good biological scores, the stream appears to have improved.

TN06010201 028 - 1000 CROOKED CREEK Blount 13.91 Siltation Pasture Grazing Unrestricted Cattle Access This stream has been considered impacted by agricultural activities. However, in 2003 the stream looked better and almost passed the biocriterion, scoring 30 on a SQSH. In 2008, TVA performed a biorecon and in 2007 TDEC performed did a SQSH on Crooked Creek. Both surveys passed. TVAs biorecon scored 11 with 9 EPT families, 2 intolerant, and 26 total families. TDECs SQSH scored 36 with 8 EPT genera and 22 total genera. Habitat was measured at 141, an acceptable score in this subecoregion. The stream will need to remain listed for pathogens.

TN06010201 033 - 0400 SOUTH FORK ELLEJOY CREEK Sevier 2.02 Riparian alteration Pasture Grazing This stream has been considered impacted by agricultural activities. In 2007 TDEC performed a SQSH survey on South Fork Ellejoy at mile 0.1 (near mouth off Dripping Springs Road).

The SQSH scored 40 with 12 EPT genera and 39 total genera, which is an excellent score. (However, the score is lower if the upstream subecoregion is used, Blue Ridge Mountains, 66e. It still passes, but the score is lowered to 32.) The habitat score was 111, an acceptable score in this subecoregion. It appears that this stream has improved.

TN06010201 033 - 0500 CARTER BRANCH Sevier 4.63 Riparian alteration Pasture Grazing This stream has been considered impacted by agricultural activities. In 2007 TDEC performed a SQSH survey on Carter Branch at mile 0.1 (off Chilhowee Road). The SQSH scored 34 with 13 EPT genera and 46 total genera, which is a good score.

The habitat score was 135, a good score in this subecoregion.

It appears that this stream has improved.

168 APPENDIX A (cont.)

Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Reason For Delisting TN06010201 040 -0600 BLACK CREEK Roane 16.7 Escherichia coli Collection System Failures This stream has been considered impacted by pathogens due to collection system problems in the Rockwood area. In 2006 and 2007, TDEC collected numerous samples at mile 2.2 (2nd bridge from mouth). None of the 16 E. coli observations were over the single sample maximum concentration criterion of 941 cfu. An October 2006 geo mean of five observations was 63.3 cfu. It appears that this stream has improved for pathogens, but will need to remain listed for fish and aquatic life impacts.

TN06010201 065 - 1000 STEEKEE CREEK Loudon 11.0 Physical Substrate Habitat Alterations Siltation Pasture Grazing This stream has been considered impacted by agricultural activities. In 2006 TDEC performed a SQSH survey on Steekee Creek at mile 0.7 (Blairland Baptist). The SQSH scored 34 with 7 EPT genera and30 total genera, which is a good score. The habitat score was 95, a little low, but the biology scored fine. It appears that this stream has improved, but will need to remain listed for pathogens.

TN06010201 066 - 1000 STOCK CREEK Knox 3.77 Physical Substrate Habitat Alterations Siltation Pasture Grazing Channelization This stream has been considered impacted by agricultural activities. In 2004, TVA performed a biorecon study that scored 15, a good score. In 2006 TDEC performed a SQSH survey on Steekee Creek at mile 3.2 (Martin Mill Road). The SQSH scored 34 with 9 EPT genera and 28 total genera, which is a good score. The habitat score was 110, an acceptable score in this subecoregion. It appears that this stream has improved, but will need to remain listed for pathogens.

TN06010201 1015 - 1000 CLOYD CREEK Loudon 11.3 Siltation Physical Substrate Habitat Alterations Pasture Grazing This stream has been considered impacted by agricultural activities. In 2007, TVA performed a biorecon study that scored 13, a good score. In 2007, TDEC performed a SQSH survey on Cloyd Creek at mile 1.5 (near Hickory Valley). The SQSH scored 38 with 10 EPT genera and 30 total genera, which is a very good score. The habitat score was 132, a good score in this subecoregion. It appears that this stream has improved, but will need to remain listed for pathogens.

TN06010208 020 - 2000 CRAB ORCHARD CREEK Morgan 2.3 pH Abandoned Mines This stream was the subject of one of the first pH TMDLs in Tennessee. During the most recent sampling cycle, the stream met pH criteria and the biology was much better. In 2007, TVA biorecon survey at mile 3.1 (Deermont Road) documented 17 EPT families, 11 intolerant, and 31 total families. The score of was 15, a perfect score. In 2006, TDEC collected a SQSH station at Deermont Road. This survey yielded 8 EPT genera and 27 total genera, for an Index score of 36. The habitat score was 165. It appears this stream is better, however, the upstream section of Crab Orchard Creek, which was closer to the abandoned mining, will need to remain listed.

169 APPENDIX A (cont.)

Waterbody ID 2006 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2006 Pollutant Source Reason For Delisting TN06030002 1124 - 0200 UNNAMED TRIB TO HESTER CREEK Lincoln 2.5 Escherichia coli Undetermined Source This stream was originally listed on the basis of a single sample collected by USGS that documented elevated pathogen levels.

In 2009, TDEC established a pathogen station at mile 0.1 (Hwy 121). Zero out of five E. coli observations were over 941 cfu.

The geometric mean of the five E. coli observations was 79 cfu.

We believe these results are representative of the overall condition of the stream and that pathogen levels do not currently exceed pathogen criteria.

TN06030005 078 - 1000 SHOAL CREEK Lawrence 13.2 Nitrates Riparian vegetation loss Industrial Point Source Municipal Point Source Removal of Riparian Vegetation Shoal Creek has been considered impaired for many years on the basis of impacts from a major industry (Murray-Ohio), a municipal point source (Lawrenceburg), plus general unban construction and agricultural runoff. Additionally an impoundment just downstream of the city added to the water quality problems. Within the last five years, the city of Lawrenceburg has upgraded its treatment capabilities, the industrial discharge has been removed, and the impoundment has been taken out. As a result, the stream now meets state biocriteria for the first time. This particularly good news for the efforts to reestablish a population of the federally endangered bolder darter in Shoal Creek. The recovery of Shoal Creek is a substantial success story that has taken many years to see to fruition. While levels of nitrate+nitrite were still a little elevated during the most recent monitoring, the recovery of the biological integrity indicates that these nutrients are not causing harm at present. TDEC will continue to monitor this stream.

TN06030005 081 - 1000 SHOAL CREEK Lawrence 21.3 Nitrates Siltation Major Industrial Point Source Major Municipal Point Source Land Development See explanation for previous segment.

TN06030005 082 - 1000 SHOAL CREEK Lawrence 2.3 Nitrates Siltation Nonirrigated Crop Production Industrial Point Source Municipal Point Source Pasture Grazing Land Development See explanation for previous segment. This segment will need to remain listed for pathogens.

170 APPENDIX A (cont.)

Waterbody ID 2006 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2006 Pollutant Source Reason For Delisting TN06030003 056 - 0250 EAST FORK MULBERRY CREEK Moore 16.8 Nitrates Siltation Low Dissolved Oxygen Municipal Point Source Discharges Pasture Grazing The biology of this stream has been considered impacted due to nutrients and BOD from the Lynchburg sewage treatment plant, plus silt from pasture areas. However, in 2009 the stream met Tennessees biointegrity standard. TDEC staff collected a SQSH sample at mile 10.2 (off Goose Branch Road ds Lynchburg STP). The sample contained 10 EPT genera and 34 total genera. The TMI score at this site was 34 (passing is a score of 32. Habitat was also good, scoring 138.

Diurnal oxygen monitoring did not indicate a continuing dissolved oxygen problem. However, this stream will need to remain listed for pathogens.

TN06030003 435 - 1000 ROLLINS CREEK Franklin Coffee 11.9 Thermal Modifications Flow alterations Industrial Point Source Biology has historically been poor in this stream. In 2009, TDEC collected a SQSH sample at mile 3.0 (off USTI Road).

This survey documented 8 EPT genera and 29 total genera.

The overall TMI score for this site 36 (passing scare is 32).

The habitat score was very good for this subecoregion at 165.

It appears that conditions in the stream have improved.

TN06030004 017 - 2000 RICHLAND CREEK Giles 26.7 Oil and Grease Industrial Point Source The Dembo facility in Pulaski was the source for oil and grease in area streams. During the most recent sampling activities, there was no evidence of oil sheens as were present in the past. For this parameter, the stream appears to have improved.

The stream will need to remain listed for siltation and pathogens.

TN08010204 001 - 1000 NORTH FORK FORKED DEER RIVER Gibson Dyer 8.34 Escherichia coli Undetermined Pathogen Source This stream was listed for pathogens based on samples collected over ten years ago. At TDECs long term ambient monitoring station at mile 7.3 (Highway 211), 40 E. coli samples have been collected since 2000. Only five of these observations were over the 941 cfu single sample max criterion.

While this is over a ten percent exceedence rate, most of the high levels were during high flow events. Stream appears to have improved for pathogens and it our judgment that the water quality standard is being met. The stream will need to remain listed for siltation and phosphorus.

TN08010205 005 -0200 MERIDIAN CREEK Haywood 36.29 Escherichia coli Pasture Grazing This stream was listed for pathogens based on samples collected in 2001-2002. In 2006-2007 TDEC established a chemical/pathogen station at mile 1.7 (Thomas Road). Two out of 24 E. coli observations were over 941 cfu. A March, 2007 geo mean of six E. coli observations was 24.0 cfu. June, 2007 geo mean of six E. coli observations = 8.0 cfu. Both geo means were well below the 126 cfu criterion. The stream will need to remain listed for low dissolved oxygen, siltation and habitat alteration.

171 APPENDIX A (cont.)

Waterbody ID 2006 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2006 Pollutant Source Reason For Delisting TN08010205 012 - 1300 CYPRESS CREEK Madison 36.9 Low Dissolved Oxygen Undetermined Source TDEC sampled this stream during the last monitoring cycle and noted massive beaver activity in the vicinity of the monitoring station. It is now believed that the low DOs noted at this station in the past were the result of stagnant conditions created by the beaver dams. This is a natural cause, not pollution.

TN08010209 016 - 0310 BAXTER BOTTOM Tipton 37.99 Low Dissolved Oxygen Nonirrigated Crop Production The stream was sampled monthly in 2007-2008 at mile 1.0 (U.S. Hwy 70). All of the dissolved observations met the water quality standard. This stream appears to have improved for dissolved oxygen, but will need to remain listed for physical substrate habitat alterations.

TN08010209 016 - 0200 MIDDLE BEAVER CREEK Tipton 65.37 Escherichia coli Pasture Grazing Middle Beaver Creek was listed for pathogens many years ago.

The stream was sampled in 2007-2008 at both mile 6.4 (Beaver Creek Road) and at mile 9.2 (Kelly Corner Road).

None of the 22 observations were over the single sample max of 941 cfu. This stream appears to have improved for pathogens, but will need to stay listed for low dissolved oxygen, siltation, total phosphorus and physical substrate habitat alterations.

TN08010211 00720- 0500 UNNAMED TRIB TO NONCONNAH CREEK Shelby 8.93 Siltation Discharges from MS4 area This stream appears to have improved for siltation. During the last monitoring cycle, 20 samples were collected for suspended solids and almost all observations were below 10 mg/L. The one exception was collected during a rain event.

TN08010211 00720- 3000 NONCONNAH CREEK Shelby Fayette 6.5 Escherichia coli Discharges from MS4 area The uppermost section of Nonconnah Creek was listed for pathogens many years ago. The stream was monitored In both 2003 and 2008 at mile 25.2 (Byhalia Road). Each time, none of the 11 observations were above the single sample maximum E.

coli criterion. This stream appears to have improved for pathogens, but will need to stay listed for total phosphorus and physical substrate habitat alterations. Perhaps the TMDL completed for this stream improved it.

APPENDIX B: Streams on the 2008 303(d) List Proposed for Delisting in 2010 For a Basis Other Than Water Quality Improvement Waterbody ID 2008 Impacted Waterbody County Miles Impacted 2008 CAUSE (Pollutant) 2008 Pollutant Source Basis For Delisting None.

172 APPENDIX C: Federally Listed Endangered Aquatic Species in the State of Tennessee Scientific Name Common Name Status Total Obs.

Pre-1975 obs.

Post-1975 obs.

HUC location of endangered species post-1975 Extirpated since 11/1975 When Listed Federal Register Citation Fish Cyprinella caerulea Blue shiner T

9 1 obs.

1974 8 obs.

1982-2000 03150101 No 462 57 FR 14790; April 22,1992 Cyprinella monacha Spotfin chub T

38 17 obs.

1936-08/1975 21 obs.

1977-2000 06010208 06010204 06010104 06010101 06010205 06010206 06040004 No 28 42 FR 45528; Sept. 9, 1977 Erimystax cahni Slender chub T

15 5 obs.

1941-1974 10 obs.

1979-1993 06010205 06010206 05130108 No 28 42 FR 45528; Sept. 9, 1977 Etheostoma boschungi Slackwater darter T

15 5 obs.

1971-1974 10 obs.

1976-1994 06040004 06030005 06030002 No 28 42 FR 45528; Sept. 9, 1977 Etheostoma percnurum Duskytail darter E

11 1 obs.

1947 10 obs.

1992-2000 06010201 05130104 06010201 06010204 No 502 58 FR 25763; April 27, 1993 Etheostoma wapiti Boulder darter E

11 0

11 obs.

1983-2001 06030004 06030003 No 322 53 FR 33998; Sept. 1, 1988 Notropis albizonatus Palezone shiner E

2 1 obs.

1936 1 obs.

1978 06010205 Yes*

502 58 FR 25763; April 27, 1993 Noturus baileyi Smoky madtom E

16 1 obs.

1957 15 obs.

1981-1995 06010204 No 163 49 FR 43069; Oct. 26, 1984 Noturus flavipinnis Yellowfin madtom T

11 5 obs.

1884-1970 6 obs.

1981-1998 06010206 06010204 06010207 No 28 Or 317 42 FR 455528; Sept. 9, 1977 Or 53 FR 29337; Aug. 4, 1988 Noturus stanauli Pygmy madtom E

5 1 obs.

1974 4 obs.

1978-1996 06040003 06010205 No 502 58 FR 25763; April 27, 1993 Percina antesella Amber darter E

6 3 obs.

1969-1973 3 obs.

1976-1978 05130101 No 196 50 FR 31603; Aug. 5, 1985 Percina jenkinsi Conasauga logperch E

7 3 obs.

1969 4 obs.

1985-2001 03150101 No 196 50 FR 31603; Aug. 5, 1985

173 APPENDIX C: Federally Listed Endangered Aquatic Species in the State of Tennessee Scientific Name Common Name Status Total Obs.

Pre-1975 obs.

Post-1975 obs.

HUC location of endangered species post-1975 Extirpated since 11/1975 When Listed Federal Register Citation Percina tanasi Snail darter T

47 3 obs.

1974-09/1975 44 obs.

1976-2000 06010201 06020001 06020002 06010204 06020004 06030004 06010104 06010108 06010107 06010201 06020003 No 12 Or 150 40 FR 47506; Oct. 9, 1975 Or 49 FR 27514; July 5, 1984 Phoxninus cumberlandensis Blackside dace T

26 0

26 obs.

1985-2000 05130101 No 273 52 FR 22585; June 12, 1987 Scaphirhynchus albus Pallid sturgeon E

3 0

3 obs.

1990 08010100 No 399 55 FR 36647; Sept. 6, 1990 Crustaceans Orconectes shoupi Nashville crayfish E

57 0

57 obs 1981-2000 5130202 No 242 51 FR 34412; Sept. 26, 1986 Mollusca Alasmidonta atropurpurea Cumberland elktoe E

19 0

19 obs.

1978-2000 05130104 05130107 No 602 62 FR 1657; Jan. 10, 1997 Alasmidonta raveneliana Appalachian elktoe E

1 0

1 obs.

1992 06010108 Yes*

563 59 FR 60334; Nov. 23, 1994 Cyprogenia stegaria (irrorata)

Eastern fanshell pearlymussel E

30 4 obs 1936-1974 26 obs 1978-1999 05130108 06010205 06020001 06040001 No 391 55 FR 25595; June 21, 1990 Dromus dromas Dromedary pearlymussel E

71 32 obs 1899-1964 39 obs 1975-1999 05130108 05130201 06010205 06010206 06020001 No 15 41 FR 24064; June 14, 1976

174 APPENDIX C: Federally Listed Endangered Aquatic Species in the State of Tennessee Scientific Name Common Name Status Total Obs.

Pre-1975 obs.

Post-1975 obs.

HUC location of endangered species post-1975 Extirpated since 11/1975 When Listed Federal Register Citation Epioblasma brevidens Cumberlandian combshell E

46 0

46 obs 1975-2000 05130104 05130108 05130201 05130202 06010205 06010206 06040002 06040003 No 602 62 FR 1657; Jan.

10, 1997 Epioblasma capsaeformis Oyster mussel E

38 0

38 obs 1979-2000 05130108 06010205 06010206 06040002 No 602 62 FR 1657; Jan.

10, 1997 Epioblasma florentina florentina Yellow-blossom pearlymussel E

25 23 obs 1913-1973 2 obs 1979-1981 05130201 Yes*

15 41 FR 24064; June 14, 1976 Epioblasma metastriata Upland combshell E

1 1 obs pre-1974 0

03150101 Yes*

495 58 FR 14339; March 17, 1993 Epioblasma obliquata obliquata Purple cats paw pearlymussel E

2 0

2 obs 1979-1982 05130201 No 394 55 FR 28213; July 10, 1990 Epioblasma torulosa gubernaculums Green-blossom pearlymussel E

13 11 obs 1913-1935 2 obs 1975-1979 06010205 06010206 Yes*

15 41 FR 24064; June 14, 1976 Epioblasma torulosa torulosa Tubercled-blossom pearlymussel E

8 6 obs 1919-1965 2 obs 1981 05130201 Yes*

15 41 FR 24064; June 14, 1976 Epioblasma turgidula Turgid-blossom pearlymussel E

17 16 obs pre-1886-1972 1 obs 1979 06040003 Yes*

15 41 FR 24064; June 14, 1976 Fusconaia cor (edgariana)

Shiny pigtoe E

56 16 obs 1913-1967 40 obs 1975-1998 06010205 06010206 06030003 No 15 41 FR 24064; June 14, 1976 Fusconaia cuneolus Fine-rayed pigtoe E

49 21 obs 1899-1973 28 obs 1978-1998 06010101 06010201 06010205 06010206 06030003 No 15 41 FR 24064; June 14, 1976 Hemistena lata Cracking pearlymussel E

33 9 obs 1914-1970 24 obs 1975-1999 06010205 06010206 06030003 06040001 No 36 43 FR 12691; March 27, 1978

175 APPENDIX C: Federally Listed Endangered Aquatic Species in the State of Tennessee Scientific Name Common Name Status Total Obs.

Pre-1975 obs.

Post-1975 obs.

HUC location of endangered species post-1975 Extirpated since 11/1975 When Listed Federal Register Citation Lampsilis abrupta Pink mucket pearlymussel E

81 12 obs 1920-1973 69 obs 1975-2001 05130108 05130201 06010104 06010107 06010201 06010205 06010207 06020001 06040001 06030001 06040005 No 15 41 FR 24064; June 14, 1976 Lampsilis virescens Alabama lampmussel E

6 5 obs 1915-1974 1 obs 1995 06030002 Yes*

15 41 FR 24064; June 14, 1976 Medionidus parvulus Coosa moccasinshell E

8 1 obs 1973 7 obs 1997-1999 03150101 No 495 58 FR 14339; March 17, 1993 Obovaria retusa Ring pink mussel E

14 7 obs 1924-1964 7 obs 1978-1999 05130201 06040001 No 369 54 FR 40112; Sept. 29, 1989 Pegias fabula Little-wing pearlymussel E

11 5 obs 1914-1966 6 obs 1981-2000 05130104 05130107 05130108 No 342 53 FR 45865; Nov. 14, 1988 Plethobasus cicatricosus White wartyback pearlymussel E

11 4 obs 1956-1964 7 obs 1978-1987 05130201 06040001 No 15 41 FR 24064; June 14, 1976 Plethobasus cooperianus Orange-foot pimpleback pearlymussel E

41 19 obs 1895-1970 22 obs 1978-1999 05130201 06010201 06010206 06020001 06040001 No 15 41 FR 24064; June 14, 1976 Pleurobema clava Clubshell E

3 0

3 obs 1978-1992 5130108 06040001 No 488 58 FR 5642; Jan. 22, 1993 Pleurobema georgianum Southern pigtoe E

11 1 obs pre-1975 10 obs 1995-1997 03150101 No 495 58 FR 14339; March 17, 1993 Pleurobema gibberum Cumberland pigtoe E

13 0

13 obs 1976-1998 05130107 05130108 06030003 No 423 56 FR 21087; May 7, 1991 Pleurobema plenum Rough pigtoe E

17 3 obs 1920-1964 14 obs 1979-1998 05130201 06010205 06020001 06040001 No 15 41 FR 24064; June 14, 1976

176 APPENDIX C: Federally Listed Endangered Aquatic Species in the State of Tennessee Scientific Name Common Name Status Total Obs.

Pre-1975 obs.

Post-1975 obs.

HUC location of endangered species post-1975 Extirpated since 11/1975 When Listed Federal Register Citation Ptychobranchus greeni Triangular kidneyshell E

2 0

2 obs 1980-1995 03150101 Yes*

495 58 FR 14339; March 17, 1993 Quadrula cylindrica strigillata Rough rabbitfoot E

24 1 obs 1960 23 obs 1975-1999 06010205 06010206 No 602 62 FR 1657; Jan. 10, 1997 Quadrula intermedia Cumberland monkeyface pearlymussel E

45 15 obs 1900-1973 30 obs 1975-2001 06010206 06030003 06040002 No 15 41 FR 24064; June 14, 1976 Quadrula sparsa Appalachian monkeyface pearlymussel E

11 2 obs 1958-1964 9 obs 1976-1998 05130201 06010206 No 15 41 FR 24064; June 14, 1976 Toxolasma cylindrellus Pale lilliput pearlymussel E

13 10 obs 1886-1970 3 obs 1982-1995 06030002 06040002 06040003 Yes*

15 41 FR 24064; June 14, 1976 Villosa perpurpurea Purple bean E

10 3 obs 1913-1970 7 obs 1985-2000 06010104 06010208 No 602 62 FR 1657; Jan. 10, 1997 Villosa trabalis Cumberland bean pearlymussel E

17 4 obs 1913-1939 13 obs 1980-2000 05130104 05130108 06010104 06010208 06020002 No 15 41 FR 24064; June 14, 1976 Snails Athearnia anthonyi Anthonys River Snail E

14 6 obs 1941-1965 8 obs 1975-1994 06010201 06010205 06020004 06030001 No 538 59 FR 17998; April 15, 1994 Pyrgulopsis (Marstonia) ogmorhaphe Royal marstonia (Obese snail)

E 4

0 4 obs 1997 03150101 No 538 59 FR 17998; April 15, 1994

  • Note: None of the extirpated species have been found on segments listed as partially or non-supporting on the 2002 303(d) List.

See the 2002 303 (d) List for endangered species located on partially or not-supporting waterbody segments.

Status:

E = Endangered T = Threatened

177