July 16, 2012 Dr. Mohamad Al-Sheikhly, Professor and Director Radiation Facilities and Nuclear Reactor Department of Materials Science and Engineering University of Maryland College Park, MD 20742-2115
SUBJECT:
UNIVERSITY OF MARYLAND C REQUEST FOR ADDITIONAL INFORMATION, RE: REACTOR OPERATOR REQUALIFICATION PROGRAM (TAC NO.
ME2431)
Dear Dr. Al-Sheikhly:
We are continuing our review of your reactor operator requalification program for the Maryland University Training Reactor, which you submitted on August 26, 2010, as an enclosure to the reply to a Notice of Violation issued to the University of Maryland in NRC Non-Routine Inspection Report No. 50-166/2010-202 as supplemented on March 14 and May 22, 2012.
During our review of your operator requalification program, questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 30 days of the date of this letter. In accordance with Title 10 of the Code of Federal Regulations Section 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your operator requalification program.
If you have any questions regarding this review, please contact me at (301) 415-1127.
Sincerely,
/GWertz for RA/
Alexander Adams, Jr., Senior Project Manager Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-166
Enclosure:
As stated cc w/enclosure:
See next page
University of Maryland Docket No. 50-166 cc:
Director, Dept. of Natural Resources Power Plant Siting Program Energy & Coastal Zone Administration Tawes State Office Building Annapolis, MD 21401 Mr. Roland G. Fletcher, Program Manager IV Radiological Health Program Maryland Department of Environment 1800 Washington Blvd., Suite 750 Baltimore, MD 21230-1718 Mr. Vincent G. Adams Facility Coordinator Chemical and Nuclear Engineering Building 090 University of Maryland College Park, MD 20742 Tom OBrien Radiation Safety Officer Department of Environmental Safety 3115 Chesapeake Building 338 University of Maryland College Park, MD 20742 Professor Robert Briber Department of Materials Science and Engineering University of Maryland College Park, MD 20742-2115 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
July 16, 2012 Dr. Mohamad Al-Sheikhly, Professor and Director Radiation Facilities and Nuclear Reactor Department of Materials Science and Engineering University of Maryland College Park, MD 20742-2115
SUBJECT:
UNIVERSITY OF MARYLAND C REQUEST FOR ADDITIONAL INFORMATION, RE: REACTOR OPERATOR REQUALIFICATION PROGRAM (TAC NO.
ME2431)
Dear Dr. Al-Sheikhly:
We are continuing our review of your reactor operator requalification program for the Maryland University Training Reactor, which you submitted on August 26, 2010, as an enclosure to the reply to a Notice of Violation issued to the University of Maryland in NRC Non-Routine Inspection Report No. 50-166/2010-202 as supplemented on March 14 and May 22, 2012.
During our review of your operator requalification program, questions have arisen for which we require additional information and clarification. Please provide responses to the enclosed request for additional information within 30 days of the date of this letter. In accordance with Title 10 of the Code of Federal Regulations Section 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your operator requalification program.
If you have any questions regarding this review, please contact me at (301) 415-1127.
Sincerely,
/GWertz for RA/
Alexander Adams, Jr., Senior Project Manager Research and Test Reactors Licensing Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-166
Enclosure:
As stated cc w/enclosure:
See next page DISTRIBUTION:
Public RidsNrrDpr RidsNrrDprPrta RTR r/f RidsNrrDprPrtb AAdams, NRR GLappert, NRR XYin, NRR GSchoenebeck, NRR ADAMS Accession No: ML121870709 NRR-088 OFFICE PRLB:LA PRLB:PM PROB:BC PRLB:BC PRLB:PM NAME GLappert XYin for AAdams GBowman JQuichocho GWertz for AAdams DATE 7/10/2012 7/11/2012 7/13/12 7/13/12 7/16/2012 Official Record Copy
REQUEST FOR ADDITIONAL INFORMATION REGARDING THE OPERATOR REQUALIFICATION PROGRAM FOR THE MARYLAND UNIVERSITY TRAINING REACTOR LICENSE NO. R-70; DOCKET NO. 50-166 The NRC has reviewed the revision to your requalification plan submitted by letter dated May 22, 2012. We noted two items for which we require additional information. Please provide responses within 30 days of the date of this letter.
- 1.
Section 5.1 of your requalification plan, in the third paragraph under Abnormal Conditions, states that the written examination will be administered biennially.
The written examination will be administered biennially, in the fourth quarter of the second year of the two year cycle In the first paragraph of Section 4.0, Requalification Program, and in Section 9.0, Administration, the frequency for the written examination is annually. Please inform the NRC of your plans to resolve this discrepancy and provide an updated requalification plan if changes are necessary.
- 2.
Section 9.0, Administration, states:
The Reactor Director will be exempt from taking every other annual written examination, but will be required to perform the operations set forth in Section 3.0 and the review of documents set forth in Section 6.0 The requirement to review documents is in Section 7.0, Document Review, and not in Section 6.0. Please inform the NRC of your plans to resolve this discrepancy and provide an updated requalification plan if changes are necessary.