IR 05000458-12-004, on 08/06/2012 - 08/10/2012, River Bend Station - Notification of Inspection (NRC Inspection and Request for Information)
ML12180A501
Person / Time
Site: River Bend 
Issue date: 06/28/2012
From: Mark Haire
Operations Branch IV
To: Olson E
Entergy Operations
References
IR-12-004
Download: ML12180A501 (7)


See also: IR 05000458/2012004

Text

UNITED STATES

NUCLEAR REGULATORY COMMISSION

RE GIO N I V

1600 EAST LAMAR BLVD

ARLINGTON, TEXAS 76011-4511

June 28, 2012

Mr. Eric W. Olson

Site Vice President

Entergy Operations, Inc.

River Bend Station

5485 US Highway 61N

St. Francisville, LA 70775

SUBJECT:

River Bend Station - NOTIFICATION OF INSPECTION (NRC INSPECTION

REPORT 05000458/2012004 AND REQUEST FOR INFORMATION

Dear Mr. Olson:

From August 6, 2012 to August 10, 2012, inspectors from the Nuclear Regulatory

Commissions (NRC) Region IV office will perform the baseline biennial requalification

inspection at River Bend Station, using NRC Inspection Procedure 71111.11B, Licensed

Operator Requalification Program. Experience has shown that this inspection is a resource

intensive inspection both for the NRC inspectors and your staff. In order to minimize the impact

to your onsite resources and to ensure a productive inspection, we have enclosed a request for

documents needed for this inspection. These documents have been divided into three groups.

The first group (Section A of the enclosure) identifies information to be provided prior to the

inspection to ensure that the inspectors are adequately prepared. The second group (Section B

of the enclosure) identifies the information the inspectors will need upon arrival at the site. The

third group (Section C of this enclosure) identifies the items which are necessary to close out

the inspection and are usually sent a few weeks after the team has left the site. It is important

that all of these documents are up to date and complete in order to minimize the number of

additional documents requested during the preparation and/or the onsite portions of the

inspection.

We have discussed the schedule for these inspection activities with your staff and understand

that our regulatory contact for this inspection will be Mr. Danny Williamson of your licensing

organization. Our inspection dates are subject to change based on your updated schedule of

examination activities. If there are any questions about this inspection or the material

requested, please contact the lead inspector Duane Strickland at (817) 200-1570

(Duane.Strickland@nrc.gov) or Gabriel Apger at (817) 200-1508 (Gabriel.Apger@nrc.gov).

This letter does not contain new or amended information collection requirements subject to the

Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). Existing information collection

requirements were approved by the Office of Management and Budget, control number 3150-

0018. The NRC may not conduct or sponsor, and a person is not required to respond to, a

E. Olson

- 2 -

request for information or an information collection requirement unless the requesting document

displays a currently valid Office of Management and Budget control number.

In accordance with 10 CFR 2.390 of the NRCs "Rules of Practice," a copy of this letter and its

enclosure will be available electronically for public inspection in the NRC Public Document

Room or from the Publicly Available Records (PARS) component of NRCs document

system (ADAMS). ADAMS is accessible from the NRC web site at http://www.nrc.gov/reading-

rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Mark S. Haire, Chief

Operations Branch

Division of Reactor Safety

Docket: 50-458

License: NPF-47

Enclosure:

Inservice Inspection Document Request

Distribution electronically to River Bend

ML12180A501

SOE:OB

C:OB

D. Strickland

M. Haire

/RA/

/RA/

06/20/2012

06/27/2012

- 1 -

Enclosure

BIENNIAL REQUALIFICATION INSPECTION DOCUMENT REQUEST

From:

Duane Strickland

Operations Engineer, NRC RIV

817-200-1570

To:

John Fralic

Requal Supervisor, River Bend Station

225-378-3530

Subject:

Information Request to Support August 6, 2012 to August 10, 2012 Licensed

Operator Requalification Program Inspection (IP 71111.11B)

A. The following information is requested in order to support inspection preparation

activities. These items are listed by section as they appear in the inspection module

(ie 2.02, 2.04, etc). Requested materials should be sent either electronically or

hardcopy in order to arrive at the Region IV office no later than July 23, 2012.

Electronically: To: Duane.Strickland@nrc.gov Cc: Gabriel.Apger@nrc.gov

Hardcopy to: US Nuclear Regulatory Commission, Region IV

1600 E. Lamar Blvd

Arlington, TX 76011

ATTN: Duane Strickland

General Requests:

List of licensed operators (SRO & RO) by crew (operating & staff)

Training and Operations Department organization charts (with qualified LOR

evaluators identified)

Procedures that identify process for revising and maintaining LO continuing training

program up to date

List of outstanding LOR program changes

List of plant events and industry operating experience incorporated into LOR

program since last BRQ

Audits and/or self-assessment reports addressing the licensed operator

requalification training program

Last two years of simulator review committee (or equivalent) meeting minutes

Last two years of CRC (or equivalent) meeting minutes

02.03: Biennial Requalification Written Examination Quality

The current and approved biennial written examination schedule

The current requalification cycle written examination results for both SRO & RO that

have already been administered up to the week prior to the inspection team arrival

onsite

All written examinations that have been approved for administration up to and

including the week before the inspection team is onsite. This will need to have

- 2 -

Enclosure

adequate password protection if e-mailed or double envelope protection if mailed via

regular mail per NUREG-1021

The current requalification cycle examination methodology (sample plan)

02.04: Annual Requalification Operating Test Quality

The schedule for the operating tests (JPMs & scenarios) to be given the week of

August 6, 2012

The operating tests (JPMs & scenarios) (password protected and provide separately

via telephone at later date) to be given the week of August 6, 2012

Current requalification cycle operating tests (SRO & RO) and results up to the week

prior to the inspection team arrival onsite

All of the previous years NRC required annual operating tests

Current requalification cycle operating test methodology (sample plan)

All portions of the UFSAR that identify operator response times for time critical

operator actions

02.05: Licensee Admin of Requal Exams

All procedures used to administer the annual operating test

All procedures used to assess operator performance

All procedures that describe conduct of simulator training

All Procedures used to test, operate, and maintain the simulator

02.06: Requalification Examination Security

Submit any tracking tools that you use as a means to prevent excessive overlap on

the written examinations and also meet the intent of sampling all required topics on a

periodic basis

Submit any tracking tools that you use as a means to prevent excessive overlap on

the operating tests and also meet the intent of sampling all required malfunctions

(including major events, instrument/component malfunctions, TS calls, etc) on a

periodic basis

All Procedures that describe examination security, including procedures used to

develop the examinations that include guidelines on overlap between examinations

in current exam cycle tests and prior year examinations

List of all Condition Reports since the last biennial requal inspection related to

examination security and overlap

02.07: Licensee Remedial Training Program

List of remedial training conducted or planned since last requal exams (includes

training provided to operators to enable passing requal exams and training provided

to correct generic or individual weaknesses observed during previous requal exam

cycle)

Remediation plans (lesson plans, reference materials, and attendance

documentation)

- 3 -

Enclosure

02.08: Conformance with Operator License Conditions

All Procedures and Program documentation for maintaining active operator licenses,

tracking training attendance, and ensuring medical fitness of licensed operators

All Procedures and associated documentation that supports reactivation of any

SRO/RO license (operating or staff crew) since the last biennial inspection

02.09: Simulator Performance

For the following cases, send the most recent transient test packages, which may be

electronic or in paper single test packages and shall be complete with test

procedures for each test, the acceptance criteria, and results. For each transient

test, the reference chart should be included or an equivalent subject matter expert

review versus the simulator results with a write-up for any differences beyond the

ANSI 3.5 standard requirements

Transient test 1, Manual Rx trip

o Transient test 6, Main turbine trip (no reactor trip)

o Transient test 10, All MSIVs closed with stuck open SRV

o Steady State tests for 50% and 100% power

All Simulator Management and Configuration Procedures if not already provided for

section 02.05 above

Simulator Discrepancy Report summary list for all open DRs. For closed DRs,

summary list for those items closed between August 2010 and August 2012

02.10: Problem Identification and Resolution

A summary report of all condition reports related to operator actions/errors in the

control room

Any revised requalification training that was based on licensed operator performance

issues

B. The following information is requested in order to support the onsite inspection

activities. Requested materials should be available to the inspection team, either

electronically or hardcopy, upon site arrival on August 6, 2012.

02.02: Exam Results / 02.03 and 02.04: Written Exam and Op Test Quality

All Operating tests (JPMs & scenarios) to be given in all subsequent weeks after

onsite week

All results up to the day the team leaves the site

02.08: Conformance with Operator License Conditions

Access to licensed operators records (operating and staff crews)

Access to licensed operators training attendance records

Access to licensed operators medical records

02.09: Simulator Performance

Simulator discrepancies (DRs) from August 2010 to August 2012. This should

include all open DRs and DRs that have been closed, including the

documentation/justification for closure

- 4 -

Enclosure

Acceptance test documentation, including hardware and software model revisions at

the time of acceptance (as available)

Documentation that validates current models, including the thermal-hydraulics and

neutronics models, to the actual plant

All current model deficiencies, including FSAR vs Design differences in the simulator

(any documentation on this)

Summary list of modifications from August 2010 to August 2012

Plant Modifications (both hardware and software) completed on the Simulator by due

date from August 2010 to August 2012

Simulator Differences Lesson plan used in training current to August 6, 2012

The complete book of all Simulator annual performance test packages (usually in a

single book, but may be electronic or in single test packages), complete with all

transient tests, steady state tests, and malfunction tests. This should also include

the test procedures for each test, the acceptance criteria, and results. For each

transient test, the reference chart should be included or an equivalent subject matter

expert review versus the simulator results with a write-up for any differences beyond

the ANSI standard requirements

All test packages used to verify core physics parameters (such as MTC, IRW). The

applicable reference graphs from the Plant physics data book (electronic or other

means as available) should also be included as well as the test procedures used and

the acceptance criteria with results

All Simulator test, configuration management, and related documents available in the

room for inspectors to review. This includes training needs analysis packages,

simulator review committee meeting minutes, etc.

Current copy of ANSI 3.5 standard you are committed to for Simulator testing

02.10: Problem Identification and Resolution

All condition reports related to operator actions/errors in the control room

C. River Bend Station is required to send the final results summary and any remaining

exams and operating tests that have not been reviewed to the regional office lead

inspector for this inspection for final review and comparison against the Significance

Determination Tools in order to communicate the exit results for the inspection.