Nuclear Operating Company South Texas Pro/ect Electric Generatinzg Station PO. Box 289 Wadsworth, Texas 77483

.A, June 14, 2012 NOC-AE-12002873 File No.: G09.19 1 0CFR50.54(a)

STI: 33563580 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 South Texas Project Units 1 and 2 Docket Nos. STN 50-498 and STN 50-499 Independent Spent Fuel Storaqe Installation

References:

1.

STPNOC letter dated January 18, 2012 from E. D. Halpin to NRC Document Control Desk, "Submittal of Revised Operations Quality Assurance Plan" (NOC-AE-12002781) ML12027A039

2.

STPNOC letter dated June 4, 2012 from K. D. Richards to NRC Document Control Desk, "Submittal of Operations Quality Assurance Plan Change QA-074" (NOC-AE-12002863)

In accordance with 10CFR72.140(d), the STP Nuclear Operating Company provides notification of its intent to apply the previously approved 10CFR50, Appendix B, quality assurance program for South Texas Project Units 1 and 2 to an Independent Spent Fuel Storage Installation to be constructed at the South Texas site. The Nuclear Regulatory Commission approved the quality assurance program for operations under Docket Nos. STN 50-498 (Unit 1) and STN 50-499 (Unit 2) in the Safety Evaluation Report dated April 29, 1986. The current quality assurance program is described in the Operations Quality Assurance Plan, Revision 20 that was effective February 1, 2012 and one interim change (QA-074) effective June 14, 2012.

In accordance with 10CFR50.54(a), STPNOC will revise the OQAP to reflect the requirements of 10CFR72.140(b) and the recordkeeping requirements of 10CFR72.174.

There are no commitments in this letter.

If there are any questions regarding this matter, please contact Ms. D. I. Towler at (361) 972-7222 or me at (361) 972-7017.

K. D. Richards President and CEO jms

NOC-AE-12002873 Page 2 of 2 cc:

(paper copy)

(electronic copy)

Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8 B13) 11555 Rockville Pike Rockville, MD 20852 Senior Resident Inspector U. S, Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN1 16 Wadsworth, TX 77483 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U. S, Nuclear Regulatory Commission Washington, DC 20555-001 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Balwant K. Singal U. S. Nuclear Regulatory Commission John Ragan Chris O'Hara Jim von Suskil NRG South Texas LP Kevin Polio Richard Pena City Public Service Peter Nemeth Crain Caton & James, P.C.

C. Mele City of Austin Richard A. Ratliff Texas Department of State Health Services Alice Rogers Texas Department of State Health Services