Nebraska Public Power District Always there when you need us 50.90 NLS2012033 May 2, 2012 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001
Subject:
Response to Request for Additional Information Regarding License Amendment Request for Implementing a 24-Month Fuel Cycle and Adoption of TSTF-493, Revision 4, Option A Cooper Nuclear Station, Docket No. 50-298, DPR-46
References:
- 1. Letter from Lynnea E. Wilkins, U.S. Nuclear Regulatory Commission, to Brian J. O'Grady, Nebraska Public Power District, dated April 3, 2012, "Request for Additional Information Re: License Amendment Request for Implementing a 24-Month Fuel Cycle and Adoption of TSTF-493, Revision 4, Option A (TAC No. ME7169)"
- 2. Letter from Brian J. O'Grady, Nebraska Public Power District, to U.S.
Nuclear Regulatory Commission, dated September 16, 2011, "License Amendment Request for Implementing a 24-Month Fuel Cycle and Adoption of TSTF-493, Revision 4, Option A" (NLS2011071)
- 3. NEDC-31336P-A, "General Electric Instrument Setpoint Methodology,"
September 1996.
Dear Sir or Madam:
The purpose of this letter is for the Nebraska Public Power District (NPPD) to respond to the Nuclear Regulatory Commission (NRC) Request for Additional Information (RAI) (Reference 1) relating to the Cooper Nuclear Station (CNS) License Amendment Request for implementing a 24-month fuel cycle and adoption of Technical Specification Task Force (TSTF) Traveler TSTF-493, Revision 4, Option A (Reference 2). The responses are provided in Attachment 1.
In Request 2 of Reference 1, the NRC requested the submittal of one of the revised Allowable Value setpoint calculations for review. In a telephone call with the NRC Project Manager on March 21, 2012, it was communicated that the setpoint calculation was prepared using the proprietary General Electric Setpoint Methodology (Reference 3). Accordingly, it must be withheld from public disclosure per 10 CFR 2.390. However, since the calculation was not prepared by the owners of the proprietary information, General Electric Hitachi, it was agreed that the NRC would waive the need for a new affidavit, provided NPPD cited the original General Electric affidavit. That affidavit is provided in Enclosure 1. Enclosures 2, 3, and 4 provide additional information associated with attached RAI response.
COOPER NUCLEAR STATION P.O. Box 98 / Brownville, NE 68321-0098 Telephone: (402) 825-3811 / Fax: (402) 825-5271 wwwnppd.com
NLS2012033 Page 2 of 2 A commitment is made in this submittal (see Attachment 2). Should you have any questions concerning this matter, please contact Mike Boyce, CNS Strategic Initiatives Project Manager, at (402) 825-5100.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on: A 'Yly A
(Dafe)
Sincerely, ttý r Brian J. O'Grady Vice President - Nuclear and Chief Nuclear Officer BJO/wv Attachments: 1. Response to Request for Additional Information Regarding License Amendment Request for Implementing a 24-Month Fuel Cycle and Adoption of TSTF-493, Revision 4, Option A
- 2. List of Regulatory Commitments
Enclosures:
- 1. Affidavit from General Electric Requesting NEDC-31336 Be Withheld From Public Disclosure
- 2. NEDC 92-050L, Rev. 2, "Calculation of Calibration Values for Low-Low Set Pressure Switches" - PROPRIETARY
- 3. NLS2011071 Replacement Pages
- 4. NEDC 11-109, Rev. 0, "Instrument Drift Analysis for NBI-PS-51 A/B/C/D" cc: Regional Administrator w/Attachments and Enclosures USNRC - Region IV Cooper Project Manager w/Attachments and Enclosures USNRC - NRR Project Directorate IV-1 Senior Resident Inspector w/Attachments and Enclosures USNRC - CNS Nebraska Health and Human Services w/Attachments and Enclosures Department of Regulation and Licensure NPG Distribution w/o Attachments and Enclosures CNS Records w/Attachments and Enclosures
NLS2012033 Page 1 of 4 Response to Request for Additional Information Regarding License Amendment Request for Implementing a 24-Month Fuel Cycle and Adoption of TSTF-493, Revision 4, Option A The Nuclear Regulatory Commission (NRC) Request for Additional Information (RAI) regarding the subject License Amendment Request (LAR) is shown in italics. The Nebraska Public Power District's (NPPD) response to each request is shown in block font.
NRC Request 1 TS SR 3.8.4.8 provides a surveillance requirement of 18 months instead of 12 months for completing the performance discharge tests. It is the NRC staff's position that SR 3.8.4.8 should be consistent with industry standard Institute of Electrical and Electronics Engineers, Inc. (IEEE) 450-1995, "Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications," Section 5.2. (c) which recommends, in part, that Annual performance tests of battery capacity should be made on any battery that shows signs of degradation or has reached 85% of the service life expected for the application. Degradation is indicated when the battery capacity drops more than 10%from its capacity on the previous performance test, or is below 90% of the manufacturer's rating.
Please provide the technical basis that justifies why an 18-month SR is acceptable as opposed to "at least once per 12 months."
NPPD Response NPPD will supplement the 24-Month Cycle License Amendment Request to revise the Surveillance Requirement (SR) 3.8.4.8 18-month frequency to 12 months, consistent with IEEE 450-1995. The amended pages will be submitted by June 2, 2012, as agreed to in the March 21, 2012 conference call.
NRC Request 2 Sections 3.1.3 and 3.1.4 of Attachment 1 to the LAR describe emergency core cooling system (ECCS) and Low-Low Set instrumentation whose current setpoint calculations do not bound the projected 30-month drift values and require revised allowable values. Calculations were not provided for these new allowable values.
NLS2012033 Page 2 of 4 Please submit one of the revised setpoint calculations for review. In addition, please submit the corresponding drift analysis with sufficient supporting documentation as to confirm adherence to the "Instrument Drift Analysis Design Guide" in Enclosure 1 of the LAR.
NPPD Response NPPD here provides NEDC 92-050L, Rev. 2, "Calculation of Calibration Values for Low-Low Set Pressure Switches" in Enclosure 2. As previously cited, NPPD requests that this calculation be withheld from public disclosure, in accordance with 10 CFR 2.390. Since application of the proprietary General Electric setpoint methodology involves mostly inputting Cooper Nuclear Station-specific values, this essentially renders the whole calculation as proprietary. Thus, it would not be meaningful to provide a redacted version with most of the calculation blacked out.
During the course of generating this response, NPPD noted a typographical error in one of the Technical Specification Table 3.3.6.3-1 Low-Low Set Instrumentation Allowable Values.
Replacement pages to the License Amendment Request are provided in Enclosure 3.
NPPD has provided NEDC 11-109, Rev. 0, "Instrument Drift Analysis for NBI-PS-51A/B/C/D (Barksdale B2T-M12SS)" in Enclosure 4. This calculation is the corresponding drift analysis for the Low-Low Set Allowable Value changes, which demonstrates adherence to the Instrument Drift Analysis Design Guide, as provided in Enclosure 1 to Reference 1.
NRC Request 3 Please provide additional detail on the surveillance test history for the ECCS. Attachment 5 page 16 of the LAR provides details for five ECCS TSfailures. Please provide the total number of surveillance tests considered or the percentage of the surveillance tests that those 5failures represent.
NPPD Response SR 3.5.1.9 is implemented by Procedures 6.1DG.302 and 6.2DG.302, "Undervoltage Logic Functional, Load Shedding, and Sequential Loading Test (DIV 1/2)." The testing described in items b) and e) on Attachment 5, Page 5 of 16, were performed under Procedure 6.1DG.302 at least eleven times from 1997 to 2009. The testing described in items a), c), and d) on, Page 5 of 16, were performed under Procedure 6.2DG.302 at least 9 times from 1997 to 2009. While this would appear to be a relatively high nominal failure rate, this is not indicative of the actual reliability of the components tested during these surveillances. As noted in the LAR, each of these five failures was unique. Additionally, many of the components tested by 6.1DG.302 and 6.2DG.302 are also tested during the monthly diesel operability tests and quarterly pump surveillance tests. In addition, Procedures 6.1EE.302 and 6.2EE.302, "4160V Bus 1F/G Undervoltage Relay and Relay Timer Functional Test (Div 1/2)" tests the undervoltage relays themselves as well as a significant portion of remaining undervoltage circuit, including the undervoltage auxiliary relays and timers.
NLS2012033 Page 3 of 4 The following more detailed disposition is provided for each of the failures provided in LAR, Page 16:
a)
For the failure involving the Service Water Pump B time-delay relay, the Service Water Pump breaker was aligned with test blocks installed and mode selector in Standby. The breaker did not close during performance of Procedure 6.2DG.302, as expected.
Investigation of this event, as described in the Apparent Cause Evaluation for this Condition Report (CR-CNS-2006-09360), found that the relay coil had failed open, which prevented the relay from changing state. This, in turn, prevented the breaker from closing as required.
The relay in question had been put into service in May 2006. In the absence of definitive evidence to the contrary, the apparent cause of the subject failure was attributed to infant mortality (May to November, 2006). The relay was purchased as a safety-related component, stored appropriately, bench-tested, and tested subsequent to being put in service. There is no evidence of any event that may have electrically or physically stressed the relay coil. These Agastat relay coils have no apparent adverse trend of failures through-out the industry.
b)
For the failure of Diesel Generator (DG)-I during testing, the failure consisted of a loss of 125VDC Control Power (Circuit 4) for DG-1 due to an overcurrent condition, caused by failure of a Transient Voltage Suppression (TVS) diode network, which ultimately resulted in DG-1 trip during a sequential loading test performed under Procedure 6.1DG.302. The Root Cause Evaluation for this Condition Report (CR-CNS-2005-01360) identified that the most likely cause of failure was a manufacturing defect of the rectifier diode in the TVS circuit causing it to short. The short circuit allowed sufficient current flow to blow the two fuses in the DG-1 Control Circuit 4. A corrective action was to replace the faulty diodes. In November 2006, a plant modification (CED 6022440) removed the TVS circuits, which included the subject diodes, and replaced them with a design that has prevented recurrence of the failure described in the Condition Report.
c)
For the out-of-specification ohm reading event, while performing Procedure 6.2DG.302, a resistance reading was not within the acceptance criteria of less than 1 ohm. Contacts were burnished and relay contact resistance was satisfactory. These are wiping contacts. The condition, while not desirable, did not prevent the associated components from actuating.
Thus, the required safety function would have been performed.
d)
For the event involving testing indications for Terminal Block YW points 4 and 5 being above acceptance criteria values, while performing Procedure 6.2DG.302, a resistance reading was not within the acceptance criteria of less than 1 ohm. Resistance was re-measured and was less than 1 ohm (this indicated that the 52/b contact on Breaker 1GB in Breaker 1 GS closing circuit was closed). This satisfactory re-measurement indicates that this condition was not a component failure.
e)
For the event involving the inability to unload DG-1 to 1000 kW, failure of DG-1 governor controls and Digital Reference Unit occurred during adjustment of DG-I load using
NLS2012033 Page 4 of 4 governor controls performed per Procedure 6.1DG.302 during testing to satisfy the 18-month requirement of SR 3.5.1.9.
The DG-1 governor controls are also used to vary DG-1 load under Procedure 6.1DG.101, "Diesel Generator 31 Day Operability Test (IST) (DIV 1)" which satisfies SR 3.8.1.3 (31 day requirement to verify synchronization and loading of each DG). Performance of the test also satisfies various other 31 day and 92 day SRs. The DG-1 governor controls are also used to vary DG-1 load under Procedure 6.1DG. 102, "Diesel Generator Demonstration of Operability Test (DIV 1)." Performance of the test satisfies various 31 day, 92 day and 184 day SRs. Accordingly, this failure would have been detected by the more frequent tests associated with DG operability tests (Procedures 6.1DG. 101 and 6.1DG. 102).
In summary, for each case, a more detailed review of the identified circuit failures has concluded that they are unique and non-recurring (including resolution through modification), or that the failures would not have prevented the required Technical Specification safety function, or that the failed components are subject to more frequent testing and would have been identified.
Accordingly, SR 3.5.1.9 may be safely extended from 18 months to 24 months without concern for undetected failures during this extended surveillance interval.
NLS2012033 Page 1 of 1 List of Regulatory Commitments Correspondence Number: NLS2012033 The following table identifies those actions committed to by Nebraska Public Power District in this document. Any other actions discussed in this submittal are provided for information purposes and are not considered to be regulatory commitments.
TYPE (Check one)
SCHEDULED COMMITMENT/COMMITMENT NO.
ONE-TIME CONTINUING COMPLETION ACTION COMPLIANCE DATE NPPD will supplement the 24-Month Cycle License Amendment Request to revise the SR 3.8.4.8 18-month frequency to 12 X
6/2/2012 months, consistent with IEEE 450-1995.
[NLS2012033-01]
NLS2012033 Page 1 of 5 Affidavit from General Electric Requesting NEDC-31336 Be Withheld From Public Disclosure
14 41
,ka flwry
- * ': *.7*.*.*.* -*;.*, * :*.*,i *,;.
Docuon" onro Ds Reere NE:C311~6t 1"Genera l.
Electic nt~et lopon Aethod ogoy",ýý: date Ocoer0 S~iBEcT PENRAL~LETRiC CoMPANY AFFJAVIT SUM.JITAL.
Per' phone4 requt of A4er
.tanky enlsdi ee~
ledtri Affiavitto potec therefe~ncd' ret originally s.
bMitt-e-oth R Oc01tober, 198660 avid 0.Rbrfanager Pln.119,in Ar e?*:. e
'C Le891 Trempe Ow/o -attch)
L W.ns Fee ndDb Collec;tion. Branclh Robet SrankY
/oe7l I/I
?AVt2 P.f
GENERAL ELECTRIC C" :LANY AFFIDAVIT I, DAVID 3. ROBARE, being duly sworn, depose and state as follows:
- 1.
I am Manager, Plant Licensing Services, Genera. Electric Company, and have beT. delegated the function of reviewing the information described in paragraph.2 which is sought to be, withheld and -have-been authorized to apply for its withholding.
- 2.
The information sought to be withheld is contained in.General Electric Report NEDC -31336, "General.Electric -nstrument Setpoiit Methodology",
dated October. 1986.
The. GE Proprietary portions of this report are identifi'able by.the NGE Proprietary Information" designation at the top of the page,
- 3.
In designating material as proprietary, General Electric utilizes the definition of proprietary information and trade secrets.set forth in the American Law Institute's Restatement of Torts:, Section 757.
This definition:provides:
-"A trade secret may consist of any.formula,. pattern,. 4device or compilation:, of informnation whitch is used in one's business and, which gives him an opportunity to obtain an advantage over competitors who do" not know or use it..A substantlaelemnt of..secrecy must exist,-
so. that, except, by.the f
there would be difficulty in acquiring information..- soe factors to be. considered in determining whether given information is. one's strade secret are (1) the extent to which the 6.:for*tion is. known outside of his business;,.(2) the0extent.to w'Ac.;-it i known by employees and
-others involved in his busines:; :3,
-.,-'ten. of measures taKen by him to guard the secrecy of6 _ýthe. iv)-
,-on;.(4) the value of the inforiation to him and:to his competitors; (5) theramount of effort or money expandedrby him developing the informati0n; (6), the ease or
-difficulty with which the information could be properly acquired or duplicated by others."
- 4.
Some examplesr o.f categories "of information-which fit into the definition of.Proprietary Information are:
a.. Information that discloses a, process, method or apparatus where prevention of its use by.:General Electric.'s competitors without
.icense from, General :Electric.constitutes a competitive economic advantage over other companies;
- b. Info.ration consisting of supporting data.and analyses,.including testdata rel ati ve to a-prcess, methodor apparatucs,the application of which provide a competitive economic advantage, e g.,
by optimZation :or improved marketability;',
SGENERL ELECTRIC COMPANY.
- c. information -which if, usedi by.a ompetitor,:." would..r)educe hi s expenditures -of resources or improve his compet.itive position in the S-design, manufacture, shipment, installation, assuranceof. quality or licensig* of a similar ProduCt;
- d. IofmatI.on-whi ch. reveals,: cost or Price information, production capacities., budget levels or commerciali.strate:qtes of Generl I Elec~tric, :Its customers or suppliers; e:: Information which reveals aspects of past, present or future Genera
.Eectric0cus.tomerfunded development plans and programs of potential coiimnrcial value to General Electric;.
- f..-
. f:"Informathion whichdiscloses patentable subject matter for which"it mAY be desirable oobanpatent protect Ion;
- g. Informatio
,whic General El*ectri c *Us treat as popr ieay..
accordi1ng to agreemeints_ With. othIer parties..
- 5.
1altial approval of proprietarmy treatmentof a-document. is. typically made by the Subsection Manage.r o the ori-i *ating component the",
person who Ismost likely to :be acquainted w i t the value and sensitivity, of
' ""." "tAhe Inforati on in relation to industt y. knowledge.
Access to such documnts within the Company is -limited aon a -ned to. kno" b..asiand s a s ~ ~
~
~'uch ouet r c'rlietfe as proprietay 6..P The pocedure. fo. approval of external release of: suc a do ument typi cal ly r.eq*
resreview by the-Sbsection Managr,. Project Manageri:
. Principa, scientist tor otherequivalent* aU*hority by the Subsection manager of:-t, the "cognizant Marketing function: (or delegate) and by te.
Legal Operaion for technical c.ontent,;
ompmetltivtiyef d eteri nation of the accuracy of the proprietary designation, In*,.
..accordance with the standards enumerated above Disciosures outside Genierali Electric are g en.eraill lIimi-ted to' reg.qulator bo-diecstmr nd,potential.=.customers. and. their lagentssuppiers and-licensees then
'":olywith appropriate protection. by applicable regulatory provisions or poretary agreements.
The document men~~~~~tioned in paragraph,2aoehsbeneautdi acco-rdancewit tthe above cri ter ia and procedues and has been, foundto" contain iformation which i's proprietary and.which its customarily held In con fidence by Genera Electric
- 8. The. nobripti on tol the best.of my knowledge6 anid elfhas consistently, bdeen. held i n confidence: by General Electric Company, no Pubic
-:discl osre ýhas been mad e,: and ti o via i n pblic ources
4p GENERAL ELECTRIC, COMIPANY
. 8.
.All discosures. to thi rd parties have been made pursuant to regulatry" pro isions of proprietary agreemepts which provide for maintenance of
- theinformation :in confidence..
P.blic di..
-sure o the i nformation oUight to be withheldis likely to cause substantial h-arm -to the *competiti ve psit on f Lthe.Gineal
.Electr fCompany and depri r
reduce.the availability of profi
- .* '-:.:-.Amaking opportunities.
A substantial effort-has been expended.by General Electric to0develop this information.
GENERAL ELECTRIC.CO PANY' AFFIDAVIT.
STATEOF CAIORZ COUTY OF -AT CLA
- David J1 Robare,bing dul"sworn, deposes and says:
That he hasi read theiforegoing affidavit and. the pmatters stated therein are truly andcorrect to th best of his knowledge,.iformation, anjibelief Executed at San. Jose.. Cali fornia this __..
day,of
'fV:i(
4 19 avd,. Roare General Electric Company Subscri bed an: sworn.before me thIs ti.day. of i'*C.
o T-Ui~.
SEAb
)L~'L Abk F1PAULA F HUJSSEY_______
Notary: -Pub ic.. State 1f.4ifrn m~y Comm. eyp4!sAR 3
I
NLS2012033 Page 1 of 4 NLS2011071 Replacement Pages Replace the following pages from NLOS2011071:, Page 18 of 35, Page 3.3-60, Page 3.3-60
NLS2011071 Page 18 of 35 3.1.4 Low-Low Set (LLS) Instrumentation NUREG-0737 Item II.K.3.16 observed that the most likely cause of a small break LOCA was from the opening of a Safety Relief Valve (SRV) where the SRV failed to reset. A reduction in this likelihood could be achieved by minimizing the number of times individual SRVs must recycle in performance of the system relief function. In addition, as part of the Mark I Containment Program, there was concern for potential high thrust loads on the discharge piping and the high frequency pressure loading on the containment. The LLS logic and instrumentation is designed to mitigate the above concerns. Upon initiation, the LLS logic will assign preset opening and closing setpoints to two preselected SRVs. These setpoints are selected such that the LLS SRVs will stay open longer (with a minimum blowdown range of 90 psi between SRV opening and closing); thus, releasing more steam to the suppression pool, and hence more energy (and time) will be required for repressurization and subsequent SRV openings.
One SRV is designated as the High LLS valve. Two pressure switches input into the LLS logic for this valve for opening and closing, respectively. A second SRV is designated as the Low LLS valve. Two different pressure switches similarly input into the LLS logic for opening and closing. The High LLS SRV is designed to open at a higher reactor pressure than the Low LLS SRV. Both SRVs are designed to close at the same pressure.
The results of the drift analysis indicated that the projected 30-month drift values for these pressure switches exceeded the drift allowance provided in the current setpoint calculation and were outside the current opening and closing TS Allowable Values for the High and Low LLS SRVs. Accordingly, revised TS Allowable Values are proposed as follows:
LLS Existing Opening Revised Opening Existing Closing Revised Closing Analytical Limit SRV Allowable Value Allowable Value Allowable Value Allowable Value (psig)
(psig)
(psig)
(psig)
(psig)
High 1005 and* 1045
> 996.5 and* 1040
> 855 and: <895
>835 and < 875.5 Open < 1050 Close >_ 825 Low
_995 and < 1035
>966.5 and < 1010
> 855 and < 895
> 835 and < 875.5 Open < 1050 Close >:
825 As shown, these revised TS Allowable Values remain bounded by their respective Analytical Limits and the 90 psi blowdown criterion.
3.2 TSTF-493, Revision 4, Option A Changes The Technical Analysis for this application is described in TSTF-493 as referenced in the NRC Notice of Availability published in the Federal Register on May 11, 2010 (75 FR 26294). Plant-specific information related to the Technical Analysis is I
I LLS Instrumentation 3.3.6.3 sable 3.3.6.3-1 Cps" i of1)
LwLAsw got tnstnametstion AMIOiN1 SMVILLANII ALt@MILIE flWWMIU S
AE
- 1.
Reactor Pressure --I,1 I per ULI valve 2, LOw-Lo Set Pressure Setpoalits 2.per ILS valve SR 3.3.6.3.3 R 1.3.6.L34 R 3.3.6.3.5 53 3.3.6.3.3 SR 3.3.6.3.4 SR 3.3.6.3.5
- 3.
DIschoaro Line Presure Sitch I per ARV SR 3.5.6.3.1 1 25 polg eW
$4 3.3.6.3.2 55 PSI, SR 3.3.6.3.4 M4 3.3.6.3.5
.9
'-K Cooper 3.3-60 Amendment No.
178
LLS Instrumentation 3.3.6.3 Table 3.3.6.3-1 (page 1 of 1)
Low-Low Set Instrumentation REQUIRED CHANNELS PER SURVEILLANCE ALLOWABLE FUNCTION FUNCTION REQUIREMENTS VALUE
- 1.
Reactor Pressure - High 1 per LLS valve SR 3.3.6.3.3
< 1050 psig SR 3.3.6.3.4 SR 3.3.6.3.5
- 2.
Low-Low Set Pressure Setpoints 2 per LLS valve SR 3.3.6.3.3 Low:
SR 3.3.6.3.4 Open > 966.5 psig SR 3.3.6.3.5 and < 1010 psig Close > 835 psig and < 875.5 psig High:
Open > 996.5 psig and < 1040 psig Close > 835 psig and < 875.5 psig
- 3.
Discharge Line Pressure Switch 1 per SRV SR 3.3.6.3.1
> 25 psig and < 55 psig SR 3.3.6.3.2 SR 3.3.6.3.4 SR 3.3.6.3.5 Cooper 3.3-60 Amendment No.