1 NRR-PMDAPEm Resource From:

Krsek, Robert Sent:

Friday, May 04, 2012 3:50 AM To:

Alley, David; Barclay, Kevin; Collins, Jay; Dennig, Robert; Feintuch, Karl; Frankl, Istvan; Grover, Ravinder; Hamm, Matthew; Hills, David; Holmberg, Mel; Jandovitz, John; Lupold, Timothy; Lyon, Warren; Neurauter, James; Patel, Jigar; Riemer, Kenneth; Schulten, Carl; Shah, Nirodh; Tsao, John; Ulses, Anthony; Walker, Harold; Wallace, Jay; Ziolkowski, Michael

Subject:

Pictures of Emergency Temporary Plug Attachments:

DSC00239.pdf; DSC00251.pdf Subject Attached. Here is what I learned:

The temporary plug is sized to fit in the socket on the 10 line (they are reusing the socket). They will have the plug staged, as well as a cutter staged, so at any point in the permanent repair process if leakage is bad, they will cut off what they have done and stick the plug on (so they thought through all the aspects of the permanent repair). The plug is silicone rated to 600 degrees F.

Draining Evolution The drain valve is on the top of the 10 inch pipe at the same height as RHR-600 penetration. They will siphon drain off this line, to get to basically the top of the pipe. They will remove the non-code repair.

Then they will stick the suction tubing of a pump and pump the pipe down.

I learned this tonight as I walked it down and wanted to ensure everyone was aware.

Robert G. Krsek Senior Resident Inspector NRC Kewaunee Resident Office Phone: 920.388.3156 Pager: 920.305.0411 Cell: 920.265.7480

Hearing Identifier:

NRR_PMDA Email Number:

357 Mail Envelope Properties (A68F3A8EA730B9499CCF1F3AC133A71615166A6D7A)

Subject:

Pictures of Emergency Temporary Plug Sent Date:

5/4/2012 3:49:36 AM Received Date:

5/4/2012 3:51:39 AM From:

Krsek, Robert Created By:

Robert.Krsek@nrc.gov Recipients:

"Alley, David" <David.Alley@nrc.gov>

Tracking Status: None "Barclay, Kevin" <Kevin.Barclay@nrc.gov>

Tracking Status: None "Collins, Jay" <Jay.Collins@nrc.gov>

Tracking Status: None "Dennig, Robert" <Robert.Dennig@nrc.gov>

Tracking Status: None "Feintuch, Karl" <Karl.Feintuch@nrc.gov>

Tracking Status: None "Frankl, Istvan" <Istvan.Frankl@nrc.gov>

Tracking Status: None "Grover, Ravinder" <Ravinder.Grover@nrc.gov>

Tracking Status: None "Hamm, Matthew" <Matthew.Hamm@nrc.gov>

Tracking Status: None "Hills, David" <David.Hills@nrc.gov>

Tracking Status: None "Holmberg, Mel" <Mel.Holmberg@nrc.gov>

Tracking Status: None "Jandovitz, John" <John.Jandovitz@nrc.gov>

Tracking Status: None "Lupold, Timothy" <Timothy.Lupold@nrc.gov>

Tracking Status: None "Lyon, Warren" <Warren.Lyon@nrc.gov>

Tracking Status: None "Neurauter, James" <James.Neurauter@nrc.gov>

Tracking Status: None "Patel, Jigar" <Jigar.Patel@nrc.gov>

Tracking Status: None "Riemer, Kenneth" <Kenneth.Riemer@nrc.gov>

Tracking Status: None "Schulten, Carl" <Carl.Schulten@nrc.gov>

Tracking Status: None "Shah, Nirodh" <Nirodh.Shah@nrc.gov>

Tracking Status: None "Tsao, John" <John.Tsao@nrc.gov>

Tracking Status: None "Ulses, Anthony" <Anthony.Ulses@nrc.gov>

Tracking Status: None "Walker, Harold" <Harold.Walker@nrc.gov>

Tracking Status: None "Wallace, Jay" <Jay.Wallace@nrc.gov>

Tracking Status: None "Ziolkowski, Michael" <Michael.Ziolkowski@nrc.gov>

Tracking Status: None Post Office:

R3CLSTR01.nrc.gov Files Size Date & Time MESSAGE 1031 5/4/2012 3:51:39 AM DSC00239.pdf 3371253 DSC00251.pdf 3203586 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: