ONGS/SCE/EIX@SCE Subject Hot Functional Testing of RSGs

! ve talked to the personnel running our test program, I've interpreted the term "Hot Functional Testing" to mean any performance related testing but not NDE (PT, MT, In-service Leak Testing, and the like as this is Code governed). Performance related testing includes hot gap testing, moisture carryover testing, blowdown capacity testing, RCS flow performance, and heat transfer performance, With the exception of hot gap testing, the test engineer indicates that the test procedures are still Revision 0 and haven't been changed from original issue. Hot gap testing was recently changed to make two major changes. In one change constituting four steps, gaps are measured at four different RCS temperatures. In two of these steps the temperatures were changed to align with natural hold points (i.e., 365 F became 350 F and 455 F to 485 F became 450 F to 500 F). In addition the soak temperature at one point was changed from between 335 F and 365 F to 320 F to 350 F. These have no change on test outcome and make it easier for Operations by not having to have multiple stopping point so close to each other. The lasi change deleted a six hour soak time at the 450 F to 500 F intermediate measurement point. During this period there is an action statement related to the steam driven AFW pump. It wasn't prudent (or necessary) to hold the startup at this DOint for a soak while in an action statement. Final measurements on gaps are made at NOP/NOTI(b)

(b()(C)

Telephone: I(b)(7)(C)

FAX:,Ib)(7)(c)

Cell:*

E-Mail: (b)(7)(C)

This communication and any of its attachments may contain Southern California Edison proprietary information, which is privileged, confidential, or subject to copyright belonging to the Southern California Edison Company. This communication is Intended solely for the use of the individual or entity to which It is addressed. If you are not the intended recipient of this communication, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this communication Is strictly prohibited and may be unlawful. If you have received this communication in error, please notify the sender immediately and permanently delete the original and any copy of this communication. Thank you.

Whhold rom Pu ic Iscios