MONTHYEARML1126501362011-09-22022 September 2011 Request for Additional Information, License Amendment Request, Revise Technical Specification 5.6.5, Core Operating Limits Report (Colr), to Replace Large-break Loss-of-Coolant Accident Analysis Methodology Project stage: RAI ML1126501262011-09-22022 September 2011 E-mail, Request for Additional Information, License Amendment Request, Revise Technical Specification 5.6.5, Core Operating Limits Report (Colr), to Replace Large-break Loss-of-Coolant Accident Analysis Methodology Project stage: RAI ET 11-0010, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.6.5, Core Operating Limits Report for Large Break Loss-of-Coolant Accident Analysis Methodology2011-10-19019 October 2011 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.6.5, Core Operating Limits Report for Large Break Loss-of-Coolant Accident Analysis Methodology Project stage: Response to RAI ET 12-0001, Supplemental Information Related to Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.6.5, Core Operating Limits Report, for Large Break Loss-of-Coolant Accident Analysi2012-01-31031 January 2012 Supplemental Information Related to Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specification 5.6.5, Core Operating Limits Report, for Large Break Loss-of-Coolant Accident Analysis Project stage: Supplement ML1210002812012-04-0505 April 2012 Request for Additional Information, Round 2, License Amendment Request, Revise Technical Specification 5.6.5, Core Operating Limits Report (Colr), to Replace Large-break Loss-of-Coolant Accident Analysis Methodology Project stage: RAI ML1210002762012-04-0505 April 2012 Email, Request for Additional Information, Round 2, License Amendment Request, Revise Technical Specification 5.6.5, Core Operating Limits Report (Colr), to Replace Large-break Loss-of-Coolant Accident Analysis Methodology Project stage: RAI ET 12-0020, Withdrawal of License Amendment Request to Revise Technical Specification 5.6.5, Core Operating Limits Report (Colr), for Large Break Loss-of-Coolant Accident Analysis Methodology2012-08-23023 August 2012 Withdrawal of License Amendment Request to Revise Technical Specification 5.6.5, Core Operating Limits Report (Colr), for Large Break Loss-of-Coolant Accident Analysis Methodology Project stage: Withdrawal ET 12-0019, Operating Corporations Comments on Draft License Renewal Interim Staff Guidance, LRISG-2012-01, Wall Thinning Due to Erosion Mechanisms2012-08-23023 August 2012 Operating Corporations Comments on Draft License Renewal Interim Staff Guidance, LRISG-2012-01, Wall Thinning Due to Erosion Mechanisms Project stage: Draft Other ML12235A4032012-09-0505 September 2012 Notice of Withdrawal of Amendment Request Revision to Technical Specification 5.6.5, Core Operating Limits Report (Colr), for Large Break Loss-of-Coolant Accident Analysis Methodology Project stage: Withdrawal ML12235A3972012-09-0505 September 2012 LTR - Withdrawal of Amendment Request Revision to Technical Specification 5.6.5, Core Operating Limits Report (Corl) for Large Break Loss-of-Coolant Accident Analysis Methodology Project stage: Withdrawal NRC-2012-0212, Notice of Withdrawal of Amendment Request Revision to Technical Specification 5.6.5, Core Operating Limits Report (Colr), for Large Break Loss-of-Coolant Accident Analysis Methodology2012-09-0505 September 2012 Notice of Withdrawal of Amendment Request Revision to Technical Specification 5.6.5, Core Operating Limits Report (Colr), for Large Break Loss-of-Coolant Accident Analysis Methodology Project stage: Withdrawal 2012-01-31
[Table View] |
Text
From:
Hall, Randy Sent:
Thursday, April 05, 2012 4:24 PM To:
Wideman Steve G Cc:
Muilenburg William T
Subject:
Request for Additional information - License Amendment Request for Wolf Creek Generating Station (TAC NO. ME4996)
Attachments:
5Apr 2012 RAI.docx April 5, 2012 Mr. Steve Wideman Wolf Creek Generating Station Wolf Creek Nuclear Operating Company
- Steve, By letter dated November 4, 2010 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML103200209), Wolf Creek Nuclear Operating Corporation (WCNOC, the licensee), submitted a License Amendment Request (LAR) for a change to the Technical Specifications (TSs) for the Wolf Creek Generating Station. Specifically, WCNOC requested a revision to TS 5.6.5, Core Operating Limits Report (COLR), to replace the existing best estimate large break loss-of-coolant accident (LOCA) analysis methodology with a methodology based on the NRC-approved topical report WCAP-16009-P-A, Realistic Large Break LOCA Evaluation Methodology Using Automated Statistical Treatment of Uncertainty Method (ASTRUM).
WCNOC provided supplemental information in letters dated October 19, 2011, and January 31, 2012.
The NRC staff has reviewed the information provided by WCNOC in the LAR and its supplements and has determined that the additional information requested in the attachment to this e-mail message is needed to complete our review. Please let me know your proposed schedule for responding to this request, and please contact me if WCNOC would like to have a conference call to discuss this RAI.
Sincerely, Randy Hall, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation USNRC (301) 415-4032 Randy.Hall@nrc.gov