ML12089A625

From kanterella
Jump to navigation Jump to search
NRC Pre-Filed Hearing Exhibit NRC000021 - Correction to Previous Response Regarding Unit 1 Buried Piping Indian Point Nuclear Generating Unit Nos. 1, 2 & 3
ML12089A625
Person / Time
Site: Indian Point  
Issue date: 01/30/2012
From: Dacimo F
Entergy Nuclear Northeast
To:
Atomic Safety and Licensing Board Panel, NRC/FSME, Office of Nuclear Reactor Regulation
SECY RAS
Shared Package
12089617 List:
References
RAS 22134, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12089A625 (6)


Text

NzEntergy Enteray Nuclear Northeast Indian Point Energy Center 450 Broadway, GSB P.O. Box 249 Buchanan, NY 10511-0249 Tel (914) 254-2055 Fred Dacimo Vice President Operations License Renewal NL-12-032 January 30, 2012 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

SUBJECT:

REFERENCE:

Correction to Previous Response Regarding Unit 1 Buried Piping Indian Point Nuclear Generating Unit Nos. 1, 2 & 3 Docket Nos.50-003, 50-247 and 50-286 License Nos. DPR-5, DPR-26 and DPR-64

1. NRC Letter dated December 30, 2008, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application - Miscellaneous Items"
2. Entergy letter (NL-09-018)," Reply to Request for Additional Information - Miscellaneous Items," dated January 27, 2009
3. NRC Letter dated May 20, 2009, "Request for Additional Information for the Review of the Indian Point Nuclear Generating Unit Numbers 2 and 3, License Renewal Application - Offsite Power, Refueling Cavity, and Unit 2 auxiliary Feedwater Pump Room Fire Event"
4. Entergy letter (NL-09-079)," Reply to Request for Additional Information Regarding Offsite Power, Refueling Cavity, and Unit 2 Auxiliary Feedwater Pump Room Fire Event," dated June 12, 2009

Dear Sir or Madam:

Entergy Nuclear Operations, Inc is providing a correction, as shown in Attachment 1 and, to the response provided by references 2 and 4 for license renewal application (LRA) Table 3.4.2-5-1 1-1P2. Entergy discovered an omission in the response to Request for Additional Information RAI's 2.3.A.4.5-2, 3.4.2-1, and 3.4.2-2. This condition was recorded in the Indian Point Energy Center (IPEC) Corrective Action Program.

Reference 2 added components to the scope of license renewal for the auxiliary feedwater pump room fire event. Reference 4 provided additional information on aging management review results for added components. In these RAI's, the portion of the Unit 1 river water system from the pump discharge to the intertie to Indian Point Unit 2 service water system was added to the scope of license renewal. The components in this portion of the river water system were added to the new LRA Table 3.4.2-5-1 1-1P2. The table identified only outdoor air as the external environment for the piping. In accordance with IPEC drawings, a portion of this piping

Docket Nos.50-003, 50-247 & 50-286 NL-12-032 Page 2 of 2 is buried and line items of piping and bolting with a soil environment should be included in Table 3.4.2-5-11-1P2. Appendix B.1.6 of the license renewal application should include the Unit 1 river water system in the list of systems containing components managed by the Buried Piping and Tanks Inspection Program. The buried piping in the river water system that is subject to aging management review had been included and remains in the IPEC buried piping program established in response to the industry initiative on buried piping.

If you have any questions, or require additional information, please contact Mr. Robert Walpole at 914-254-6710.

I declare under penalty of perjury that the foregoing is true and correct. Executed on Sincerely, FRD/cbr

Attachment:

1.

Revised Table 3.4.2-5-11-1P2

2.

Revised Appendix B.1.6 cc:

Mr. William Dean, Regional Administrator, NRC Region I Mr. Sherwin E. Turk, NRC Office of General Counsel, Special Counsel Mr. Dave Wrona, NRC Branch Chief, Engineering Review Branch I Mr. Robert F. Kuntz, NRC Sr. Project Manager, Division of License Renewal Mr. John Boska, NRR Senior Project Manager Mr. Paul Eddy, New York State Department of Public Service NRC Resident Inspector's Office Mr. Francis J. Murray, Jr., President and CEO NYSERDA

ATTACHMENT I TO NL-12-032 Correction to Previous Response Regarding Unit I Buried Piping REVISED TABLE 3,4.2-5-11-1P2 ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 1, 2 & 3 DOCKET NOS.50-003, 50-247 AND 50-286

Summary of Aging Management Review Table 3.4.2-5-11-1P2: River Water Service System NUREG-Component Intended Aging Effect Aging 1801 Table Cmpnen Fntend Material Environment Requiring Management 181 1

Notes Type Function Management Programs Vol. 2 Item Item Bolting Pressure Carbon Soil (ext)

Loss of Buried Piping VII.C1-3.3.1-C boundary steel material and Tanks 18 19 Inspection (A-01)

Piping Pressure Carbon Soil (ext)

Loss of Buried Piping VIIC1-3.3.1-A boundary steel material and Tanks 18 19 Inspection (A-01)

ATTACHMENT 2 TO NL-12-032 Correction to Previous Response Regarding Unit I Buried Piping Revised Appendix B.1.6 ENTERGY NUCLEAR OPERATIONS, INC.

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 1, 2 & 3 DOCKET NOS.50-003, 50-247 AND 50-286

B.1.6 BURIED PIPING AND TANKS INSPECTION Proaram Description The Buried Piping and Tanks Inspection Program is a new program that includes (a) preventive measures to mitigate corrosion and (b) inspections to manage the effects of corrosion on the pressure-retaining capability of buried carbon steel, gray cast iron, and stainless steel components. Preventive measures are in accordance with standard industry practice for maintaining external coatings and wrappings. Buried components are inspected when excavated during maintenance. If trending within the corrective action program identifies susceptible locations, the areas with a history of corrosion problems are evaluated for the need for additional inspection, alternate coating, or replacement. The program applies to buried components in the following systems.

Safety injection Service water Fire protection Fuel oil Security generator City water Plant drains I

Auxiliary feedwater Containment isolation support River water service (IP1)