ML12088A038

From kanterella
Jump to navigation Jump to search
Request for Approval of Secure Voice Communications Ccore Module by Cellcrypt Limited
ML12088A038
Person / Time
Site: Palo Verde  
Issue date: 03/09/2012
From: Mins D
Arizona Public Service Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
102-06487-DCM/DLK
Download: ML12088A038 (5)


Text

10 CFR 73.22(f)(3)

YAM A subsidiary of Pinnacle West Capital Corporation Palo Verde Nuclear Generating Station Dwight C. Mims Sr. Vice President Nuclear Regulatory and Oversight Tel. 623-393-5403 Fax 623-393-6077 Mail Station 7605 P.O. Box 52034 Phoenix, Arizona 85072-2034 102-06487-DCM/DLK March 9, 2012 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Information Security Branch Washington, DC 20555-0001

References:

(1) Title 10, Code of Federal Regulations Part 73.22(f)(3)

(2) National Institute of Standards and Technology (NIST) Cryptographic Module Validation Program (CMVP)

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1, 2, and 3 Docket Nos. STN 50-528, 50-529, and 50-530 Request for Approval of Secure Voice Communications CCORE Module by Cellcrypt Limited Per 10 CFR 73.22(f)(3) (Ref. 1), Arizona Public Service Company requests approval to use mobile telephone devices to transmit safeguards information with the Cellcrypt MobileTM application and the CCORE Cryptographic Module by Cellcrypt Limited. This module meets the requirements of Federal Information Processing Standard (FIPS) 140-2 per the latest validation list of Reference 2. Enclosed is Validation Certificate No.

1310 for the CCORE Cryptographic Module.

If you have any questions, please contact Thomas Weber, nuclear regulatory affairs department leader, at (623) 393-5764.

A member of the STARS (Strategic Teaming and Resource Sharing) Alliance S;C)D/'/-ý v aif E"J1- "

Callaway

  • Comanche Peak
  • Diablo Canyon - Palo Verde
  • Wolf Creek

ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Request for Approval of Secure Voice Communications Page 2 Arizona Public Service Company makes no commitments in this letter.

Sincerely, DCM/TNW/DLK

Enclosure:

FIPS 140-2 Validation Certificate No. 1310 for CCORE Module by Cellcrypt Limited cc:

E. E. Collins Jr.

B. K. Singal L. K. Gibson J. R. Hall M. A. Brown NRC Region IV Regional Administrator NRC NRR Project Manager for PVNGS (electronic and paper)

NRC NRR Project Manager for PVNGS (electronic)

NRC NRR Senior Project Manager (electronic)

NRC Senior Resident Inspector for PVNGS A member of the STARS (Strategic Teaming and Resource Sharing) Alliance Callaway

  • Comanche Peak
  • Diablo Canyon - Palo Verde -

San Onofre

  • Wolf Creek

ENCLOSURE FIPS 140-2 Validation Certificate No. 1310 for CCORE Module by Cellcrypt Limited

FIPS 140-2 Validatio Certificate Tf e~m"euWnm.Mioruaftroe m8d TmWWWW.O1#UphtdUI.

of Ainudsg

The, See 1"mly GeU*$dmEo1VQovuntmwt Certificate No. 1310 The National Institute of Standards and Technology, as the United States FIPS 140-2 Cryptographic Module Validation Authority; and the Communications Security Establishment, as the Canadian FIPS 140-2 Cryptographic Module Validation Authority; hereby validate the FIPS 140-2 testing results of the Cryptographic Module identified as:

CCORE Module by Cellcrypt Limited in accordance with the Derived Test Requirements for FIPS 140-2, Security Requirements for Cryptographic Modules.

FIPS 140-2 specifies the security requirements that are to be satisfied by a cryptographic module utilized within a security system protecting Sensitive Infrmation (United States) or Protected Information (Canada) within computer and telecommunications systems (including voice systems).

Products which use the above identified cryptographic module may be labeled as complying with the requirements of FIPS 140-2 so long as the product, throughout its life cycle, continues to use the validated version of the cryptographic module as specified in this certificate. The validation report contains additional details concerning test results. No reliablity test has been performed and no warrnty of the products by both agencies is either expressed or implied.

This certificate includes details on the scope of conformance and validation authority signatures on the reverse.

TM:AO&MuWaUckn M"l & NMT~ljdmf~

  1. ~rsngtJ6ZU.U.

awGmeM

FIPS 140-2 provides four increasing, qualitative levels of security: Level 1, Level 2, Level 3, and Level 4. These levels are intended to cover the wide range and potential applications and environments in which cryptographic modules may be employed. The security requirements cover eleven areas related to the secure design and implementation of a cryptographic module. The scope of conformance achieved by the cryptographic modules as tested in the product identified as:

CCORE Module by Cellcrypt Limited (Software Version: 0.6.0-rc3; Software)

CEAL: a CygnaCom Solutions Laboratory, NVLAP Lab Code 200002-0 CRYPTIK Version 7.0 and tested by the Cryptographic Module Testing accredited laboratory:

is as follows:

Cryptographic Module Specification:

Roles, Services, and Authentication:

Physical Security:

(Multi-Chip Standalone)

EMI/EMC:

Design Assurance:

Operational Environment:

Level 1 Level 1 Level N/A Cryptographic Module Ports and Interfaces:

Finite State Model:

Cryptographic Key Management:

Level 1 Level 1 Level 1 Level 1 Level I Level 1 Self-Tests:

Mitigation of Other Attacks:

tested in the following configuration(s): Ubuntu Server Level 1 Level N/A The following FIPS approved Cryptographic Algorithms are used: AES (Cert. #1089); RSA (Cert. #514); SHS (Cert. #1022); HMAC (Cert. #612);

RNG (Cert. #611)

The cryptographic module also contains the following non-FIPS approved algorithms:

RSA (key wrapping; key establishment methodology provides 112 bits of encryption strength); RC4; MD5; EC Diffie-Hellman (non-compliant); ECDSA (non-compliant)

Overall Level Achieved: I Signed on behalf of the Government of the United States Signature:

iALA~ Ig,2-oiO Signed on behalf of the Government of Canada Signature: C =

Dated:

Dated:

/1C_ 1 I'D.

Qt r1,z Chief, Computer Qcurity Division National Institute of Standards and Technology I

Director, Industry Program Group Communications Security Establishment Canada