1CAN031203, Unit 1, Steam Generator Tube Inspection Report - 1R23
| ML12086A294 | |
| Person / Time | |
|---|---|
| Site: | Arkansas Nuclear |
| Issue date: | 03/22/2012 |
| From: | Pyle S Entergy Operations |
| To: | Office of Nuclear Reactor Regulation, Document Control Desk |
| References | |
| 1CAN031203 | |
| Download: ML12086A294 (104) | |
Text
1CAN031203 March 22, 2012 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
Subject:
Steam Generator Tube Inspection Report - 1R23 Arkansas Nuclear One - Unit 1 Docket No. 50-313 License No. DPR-51
Dear Sir or Madam:
Entergy Operations, Inc. (Entergy) inspected the Arkansas Nuclear One, Unit 1 (ANO-1) steam generator (SG) tubes during the Fall (October) 2011 refueling outage (1R23) in accordance with ANO-1 Technical Specification (TS) 5.5.9, Steam Generator (SG) Program.
ANO-1 TS 5.6.7 requires that the results of inspections performed during the report period be submitted to the NRC within 180 days after the initial entry into Mode 4. Enclosed is the subject inspection report.
The 1R23 inspection performed on both SGs involved an initial full-length bobbin coil examination. The X-probe used consists of an array of coils for diagnostic testing.
This submittal completes the reporting requirements of the ANO-1 TSs for this inspection.
This submittal contains no regulatory commitments. Should you have any questions, please contact me.
Sincerely, Original signed by David B. Bice for Stephenie L. Pyle SLP/rwc
Enclosure:
Results of ANO-1 SG Tube Inspections During 1R23 Entergy Operations, Inc.
1448 S.R. 333 Russellville, AR 72802 Tel 479-858-4704 Stephenie L. Pyle Manager, Licensing Arkansas Nuclear One
1CAN031203 Page 2 of 2 cc:
Mr. Elmo E. Collins Regional Administrator U. S. Nuclear Regulatory Commission, Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511 NRC Senior Resident Inspector Arkansas Nuclear One P. O. Box 310 London, AR 72847 U. S. Nuclear Regulatory Commission Attn: Mr. Kaly Kalyanam MS O-8 B1 One White Flint North 11555 Rockville Pike Rockville, MD 20852 Mr. Bernard R. Bevill Arkansas Department of Health Radiation Control Section 4815 West Markham Street Slot #30 Little Rock, AR 72205
ENCLOSURE TO 1CAN031203 Results of ANO-1 SG Tube Inspections During 1R23
Enclosure to 1CAN031203 Page 1 of 13 RESULTS OF ANO-1 SG TUBE INSPECTIONS DURING 1R23 1
INTRODUCTION Arkansas Nuclear One, Unit 1 (ANO-1) Technical Specification (TS) 5.6.7, Steam Generator Tube Inspection Reports, requires Entergy Operations, Inc. (Entergy) to submit a 180 day report to the NRC that outlines the details of the steam generator (SG) tubing inspections that were performed during the reporting period. The report shall include:
- 1.
The scope of inspections performed on each SG.
- 2.
Active degradation mechanisms found.
- 3.
Nondestructive examination (NDE) techniques utilized for each degradation mechanism.
- 4.
Location, orientation (if linear), and measured sizes (if available) of service induced indications.
- 5.
Number of tubes plugged during the inspection outage for each active degradation mechanism.
- 6.
Total number and percentage of tubes plugged to date.
- 7.
The results of condition monitoring, including the results of tube pulls and in-situ testing.
The operating period for this report includes one refueling inspection outage (1R23) in October 2011. The previous inspection included only the tubes around the tie rods (1R22).
The purpose of the 1R22 inspection was to evaluate the extent of tie rod bowing. The detected wear at the tube support plates (TSPs) permitted omitting this inspection in 1R23.
The outage prior to 1R22 (1R21) included a 100% bobbin inspection.
This report details the result of the 1R23 inspection. The inspection was a 100% full-length bobbin inspection, as well as utilizing the X-probe for diagnostic testing. Three damage mechanisms were identified (two previous and one new). Tie rod bowing and TSP wear has been identified in both SGs previously. Tube-to-tube wear has now been identified in both SGs for the first time. This condition was entered into the site corrective action program. No identified damage mechanism challenged the performance criteria for leakage or burst.
2 DESIGN The replacement SGs for ANO-1 are Enhanced Once-Through Steam Generators (EOTSG) manufactured by AREVA. The EOTSG is a straight shell-and-tube type heat exchanger installed in a vertical position with bottom supports and emergency supports as required to accommodate normal and accident loads. The tubing consists of Inconel 690 thermally treated tubing that is 5/8" in diameter with a 0.037" wall thickness. The tubes are expanded full depth hydraulically in the tubesheet. There are 15 TSPs that are constructed of stainless steel (SA 240 type 410) and are a broached trefoil-hole design.
Enclosure to 1CAN031203 Page 2 of 13 3
Report Requirements 3.1 The scope of inspections performed on each SG.
Table 3.1.1 1R23 Inspection Scope Examination Type Inspections Conducted
% Scope Extent Tested SG A Bobbin Initial 15587 100 TEC to TEH X-Probe/Plus Point 736 N/A N/A SG B Bobbin Initial 15591 100 TEC to TEH X-Probe/Plus Point 250 N/A N/A Note: TEC Tube End Cold TEH Tube End Hot 3.2 Active degradation mechanisms found.
1R23 was the fourth inservice inspection (ISI) following replacement of the SGs. There were three mechanisms identified (mechanical wear at TSPs, tube-to-tube wear and tie rod/tube bowing). These are listed in Table 3.2.1.
Table 3.2.1 Indication List for 1R23 SG TSP Wear Tube-to-Tube Wear Proximity (tie rod bowing)
A 1492 48 92 B
1414 78 26
Enclosure to 1CAN031203 Page 3 of 13 3.3 NDE techniques utilized for each degradation mechanism.
Site-Specific Review Deemed Acceptable Site Technique (ETSS)
Site ETSS Industry Qualification Damage Mechanism Demonstrated Applicability Extended Applicability Detection Sizing 1
Bobbin 1
96004.1, Rev. 13 96043.1, Rev. 1 TSP Wear Broach TSP Drill TSP Possible Loose Part wear Tie rod-to-tube wear Tube-to-tube wear*
(if similar morphology)
Yes Yes 2 X-Probe 2
20400.1, Rev. 5 20402.1, Rev. 5 20403.1, Rev. 5 20500.1, Rev. 4 20501.1, Rev. 4 20502.1, Rev. 4
- freespan, support structures, dents None Yes No Utilized sizing correlation by Three Mile Island (TMI) for bobbin depth sizing that was site qualified.
Note: ETSS Examination Technical Specification Sheet ODSCC Outside Diameter Stress Corrosion Cracking PWSCC Pure Water Stress Corrosion Cracking 3.4 Location, orientation (if linear), and measured sizes (if available) of service induced indications.
The only service induced mechanisms were mechanical wear at the TSPs and tube-to-tube wear. There were no wear indications associated with proximity tubes (tubes in close contact or contacting adjacent tubes due to tie rod bowing). Due to the large number of indications, these are listed in the following attachments:
SG A Tube-to-Tube Wear SG B Tube-to-Tube Wear SG A TSP Wear SG B TSP Wear
Enclosure to 1CAN031203 Page 4 of 13 3.5 Number of tubes plugged during the inspection outage for each active degradation mechanism.
There were 16 tubes plugged in 1R23 with 15 of these tubes being stabilized. The tube that could not be stabilized was caged with the surrounding tubes by plugging and stabilizing those tubes. Listed below in Tables 3.5.1 and 3.5.2 is a summary of the plugged tubes for SG A and SG B, respectively:
Table 3.5.1 SG A Repaired Tubes in 1R23 Row Tube Repair Type Reason 42 8
Plug and Stabilize Tie Rod Bowing 15th Span due to extent of bowing 43 7
Plug and Stabilize Bounds Tube 43-8 43 8
Plug Tie Rod Bowing 1st Span 43 9
Plug and Stabilize Bounds Tube 43-8 44 8
Plug and Stabilize Bounds Tube 43-8 44 9
Plug and Stabilize Bounds Tube 43-8 88 9
Plug and Stabilize Tie Rod Bowing 1st Span Table 3.5.2 SG B Repaired Tubes in 1R23 Row Tube Repair Type Reason 1
3 Plug and Stabilize 43% Through-Wall (TW) 1 5
Plug and Stabilize 46% TW 2
22 Plug and Stabilize 36% TW 11 15 Plug and Stabilize 36% TW 12 15 Plug and Stabilize 35% TW 26 1
Plug and Stabilize 37% TW 109 109 Plug and Stabilize Tie Rod Bowing 10th Span due to extent of bowing 110 106 Plug and Stabilize Tie Rod Bowing 10th Span due to extent of bowing 150 4
Plug and Stabilize 35% TW 3.6 Total number and percentage of tubes plugged to date.
There were no sleeves installed in either generator. The aggregate plugging information is listed in Table 3.6.1 below.
Enclosure to 1CAN031203 Page 5 of 13 Table 3.6.1 Cumulative Plugs in Service SG A Year Outage Installed Cumulative
% Plugged 2004 Fabrication 2 (welded) 2 0.013 2005 Baseline (1R19) 0 2
0.013 2007 First ISI 1R20 0
2 0.013 2008 1R21 8
10 0.064 2010 1R22 0
10 0.064 2011 1R23 7
17 0.109 SG B Year Outage Installed Cumulative
% Plugged 2005 Fabrication 0
0 0
2005 Baseline (1R19) 0 0
0 2007 First ISI 1R20 1
1 0.006 2008 1R21 5
6 0.038 2010 1R22 0
6 0.038 2011 1R23 9
15 0.096 Note - 15597 total tubes so 0.1% = ~15 tubes 3.7 The results of condition monitoring, including the results of tube pulls and in-situ testing.
All condition monitoring requirements for the tubing performance criteria were met. There were no indications that exceeded performance criteria or in-situ screening limits. No tube pulls were required.
Proximity is an indicator of tube bowing. The bowing resulted from tie rod bowing due to a compressive load applied during cool down from locking of the TSPs in the upper shroud.
This was originally presented to the NRC in a presentation on August 29, 2007 (a non-proprietary version of the presentation material provided for the meeting can be found in ADAMS (ML072420379)). The results of the NDE inspection of SG A, which included a full-length bobbin inspection of 100% of the tube bundle and inspection of the tubes surrounding each of the tie rods with an X-Probe (combination array probe which includes bobbin coils and diagnostic coils), indicated a decrease in the number of affected tubes compared to 1R22. Five new tube-to-tie rod proximity indications were detected, one in the 1st span, two in the 14th span, and two in the 15th span. No additional tube-to-tube proximity indications were detected. The general pattern was the same as that of the previous inspections with the addition of one location in the third ring (from the periphery) of tie rods in the first span. One location in the 15th span indicated progression to tube-to-tie rod contact.
Enclosure to 1CAN031203 Page 6 of 13 The results of the NDE inspection of SG B, which included a full-length bobbin inspection of 100% of the tube bundle, included proximity indications in SG B for the first time. This was entered into the site corrective action program. Each of the tubes that had proximity signals on the bobbin data were subsequently inspected with an X-Probe (array/bobbin combination).
A review of the eddy current testing (ECT) data from 1R22 did not reveal any signals that were consistent with tube-to-tie rod or tube-to-tube proximity. Therefore, the tie rod bowing at these locations was reasonably concluded to be new. There were seven locations of tie-rod-to-tube contact in the 1st span of SG B, compared to eleven locations of tie-rod-to-tube contact in the 1st span of SG A at 1R20.
Listed below in Tables 3.7.1 and 3.7.2 are the lateral bowing extents by location for the last four outages.
Table 3.7.1 SG A Bowing History (in lateral inches)
OUTERMOST RING Bow at 1R20 Bow at 1R21 Bow at 1R22 Bow at 1R23 1st Span Row 12 None detected None detected 0.167 Proximity not found (1)
Row 24 0.250 0.691 0.891 0.809 Row 42 0.450 0.726 0.979 0.875 Row 64 0.868 1.158 1.283 1.243 Row 88 0.748 1.025 1.241 1.187 Row 110 0.498 0.797 1.039 0.968 Row 128 0.250 0.446 0.559 0.422 2nd Span Row 24 None detected None detected 0.032 Proximity not found (1)
Row 42 None detected 0.135 0.165 0.118 Row 64 None detected None detected Not Determinable (2)
Not Determinable (2)
Row 88 None detected 0.124 Not Determinable (2)
Not Determinable (2)
Enclosure to 1CAN031203 Page 7 of 13 Table 3.7.1 (continued)
SG A Bowing History (in lateral inches)
OUTERMOST RING Bow at 1R20 Bow at 1R21 Bow at 1R22 Bow at 1R23 11th Span Row 42 None detected None detected 0.053 Proximity not found (1)
Row 64 None detected None detected Not Determinable (2)
Not Determinable (2)
Row 88 None detected None detected Not Determinable (2)
Not Determinable (2)
Row 110 None detected None detected 0.060 None detected 12th Span Row 42 None detected None detected 0.038 0.053 Row 64 None detected None detected Not Determinable (2)
Not Determinable (2)
Row 88 None detected None detected Not Determinable (2)
Not Determinable (2) 13th Span Row 42 None detected 0.070 0.053 0.045 Row 64 None detected None detected Not Determinable (2)
Not Determinable (2)
Row 88 None detected None detected Not Determinable (2)
Not Determinable (2)
Row 128 None detected None detected 0.026 0.013 14th Span Row 42 None detected 0.043 0.039 0.051 Row 64 0.085 0.121 Not Determinable (2)
Not Determinable (2)
Row 88 0.036 0.125 Not Determinable (2)
Not Determinable (2)
Row 110 None detected None detected 0.065 0.099 Row 128 None detected None detected None detected 0.031
Enclosure to 1CAN031203 Page 8 of 13 Table 3.7.1 (continued)
SG A Bowing History (in lateral inches)
OUTERMOST RING Bow at 1R20 Bow at 1R21 Bow at 1R22 Bow at 1R23 15th Span Row 12 None detected None detected None detected 0.148 Row 24 None detected 0.067 0.043 0.098 Row 42 0.141 0.147 0.151 0.226 Row 64 0.114 0.098 Not Determinable (2)
Not Determinable (2)
Row 88 0.129 0.125 Not Determinable (2)
Not Determinable (2)
Row 110 None detected 0.115 0.083 0.117 Row 128 None detected 0.126 0.117 0.111 SECOND OUTERMOST RING Bow at 1R20 Bow at 1R21 Bow at 1R22 Bow at 1R23 1st Span Row 33 None detected None detected 0.220 0.350 Row 47 None detected 0.462 0.573 0.634 Row 66 0.376 0.550 0.727 0.862 Row 86 0.248 0.550 0.667 0.726 Row 105 0.244 0.442 0.573 0.632 2nd Span Row 47 None detected None detected 0.086 0.100 Row 66 None detected None detected 0.085 0.107 Row 86 None detected None detected 0.082 0.106 Row 105 None detected None detected 0.044 Proximity not found (1) 13th Span Row 86 None detected None detected 0.020 0.003
Enclosure to 1CAN031203 Page 9 of 13 Table 3.7.1 (continued)
SG A Bowing History (in lateral inches)
SECOND OUTERMOST RING Bow at 1R20 Bow at 1R21 Bow at 1R22 Bow at 1R23 14th Span Row 86 None detected 0.073 0.055 0.065 15th span Row 86 None detected 0.041 0.034 0.057 THIRD OUTERMOST RING Bow at 1R20 Bow at 1R21 Bow at 1R22 Bow at 1R23 1st Span Row 85 None detected None detected None detected 0.237 Maximum 1st Span Bow 0.868 1.158 1.283 1.243 Maximum Upper Spans 0.085 0.147 0.165 0.226 1 The previous proximity indication(s) at this location was not found on ECT at 1R23.
- 2.
The tie rod bowing at this location could not be determined because the adjacent tubes have been plugged, and the tie rod bowing has not progressed sufficiently to decrease the gap between the plugged tubes and adjacent tubes such that a proximity signal was detected by the ECT.
Enclosure to 1CAN031203 Page 10 of 13 Table 3.7.2 SG B Bowing History (in lateral inches)
OUTERMOST RING Bow at 1R20 Bow at 1R21 Bow at 1R22 Bow at 1R23 1st Span Row 64 None detected None detected None detected 0.468 Row 88 None detected None detected None detected 0.503 Row 110 None detected None detected None detected 0.430 Row 128 None detected None detected None detected 0.426 10th Span Row 110 None detected None detected None detected 0.153 14th Span Row 110 None detected None detected None detected 0.066 15th Span Row 64 None detected None detected None detected 0.099 Row 88 None detected None detected None detected 0.096 Row 110 None detected None detected None detected 0.258 Row 128 None detected None detected None detected 0.131 Row 140 None detected None detected None detected 0.122 SECOND OUTERMOST RING Bow at 1R20 Bow at 1R21 Bow at 1R22 Bow at 1R23 1st Span Row 86 None detected None detected None detected 0.238 Row 105 None detected None detected None detected 0.182 Maximum 1st Span None detected None detected None detected 0.503 Maximum Upper Spans None detected None detected None detected 0.258
Enclosure to 1CAN031203 Page 11 of 13 TSP Wear During 1R23, a significant number of new wear indications were detected and sized using a wear standard. A review of the previous ECT data was performed to confirm that newly reported wear indications were actually new. The inspection during 1R22 was limited to tubes surrounding the tie rods; therefore, the 1R23 wear data was compared to the 1R21 wear data to evaluate growth and trending. The wear patterns in each of the SGs were essentially unchanged, though there appeared to be a new pattern of appreciable wear at TSP 6 in SG A. The total number of wear indications in SG A has increased by approximately 51%.
The total number of wear indications in SG B has increased by approximately 37%. The maximum depth during 1R23 was 46% TW in SG B compared to 32% TW in both SGs during 1R21.
There has been no significant change in the distribution of wear as a function of tubesheet radius since 1R21, with the majority of the wear indications at a radius greater than 35 inches from the center of the bundle. There were a few new wear indications in the lower spans; however, the depth of these indications was less than 10% TW. Otherwise, the distribution of wear indications as a function of the TSP elevation was similar to that indentified in previous inspections. New wear indications were characterized with 93% of the new indications in SG A and 96% of the new indications in SG B having a flat orientation. The wear depths during 1R23 were slightly deeper than past inspections because all of the indications have had two cycles of operation to grow, with only a small percentage taken out-of-service by plugging. Table 3.7.3 summarizes the TSP wear:
Table 3.7.3 Summary of TSP Wear SG A SG B Total number of in-service tubes 15587 15591 Number of wear indications 1492 1414 Number of tubes with wear 1322 1108
% of in-service tubes with wear 8.5%
7.1%
Number of new wear indications 501 396 Number of repeat wear indications 991 1018 New average depth 8.7% TW 9.8% TW Average depth of total wear indications 8.8% TW 10.5% TW Maximum depth 32% TW 46% TW Number of indications > 40% TW 0
2 Number of indications 20% but 39%
36 68 Number of indications 19 %
1456 1344
Enclosure to 1CAN031203 Page 12 of 13 SG A SG B Average growth rate (new + repeat) 3.68 % TW /
Effective Full Power Year (EFPY) 4.28 % TW / EFPY 95th percent growth rate (repeat) 1.87 % TW / EFPY 2.62 % TW / EFPY 95th percent growth rate (new) 14 % TW / EFPY 17 % TW / EFPY Maximum growth (repeat) 7.12 % TW / EFPY 9.37 % TW / EFPY Maximum growth (new) 11.24 % TW / EFPY 13.12 % TW / EFPY Number of tubes plugged for wear 0
7 Average Growth Rate (Combined, New +
Repeat) 11.69% TW / EFPY 95th Percentile Growth Rate (Combined, Repeat) 2.25% TW / EFPY 95th Percentile Growth Rate (Combined, New) 15.00% TS / EFPY The detailed listing of individual indications is found in Attachment 3 for SG A and for SG B.
Tube-to-Tube Wear A meeting with the NRC was conducted on January 26, 2012 (a copy of the ANO-1 slides can be found in ADAMS (ML120250111)), to discuss this new mechanism in conjunction with TMI.
Both ANO-1 and TMI performed SG inspections during the fall of 2011. Numerous freespan (not coincident with a tube support or tubesheet) bobbin coil Absolute Drift Indications were detected at the first ISI of the SGs at TMI. Scrutiny of these determinations resulted in the conclusion that these were actually indications of tube-to-tube wear. Further diagnostic tests with +Point' and X-probes were performed to confirm the presence of wear indications in the mid-span regions of the SG. Most of the wear indications were detected in either the 8th or 9th spans of the tube bundle, mid-span between broached TSPs. There were no corresponding indications of tube-to-tube proximity caused by bowing of the affected tubes. Based on the findings at TMI, a complete reanalysis of the ANO-1 bobbin coil data was performed by AREVA beginning with the first ISI during 1R20. The evaluation determined that during 1R23, there were 48 tubes in SG A and 78 tubes in SG B, for a total of 126 tubes with indications. A
%TW depth was assigned using a bobbin voltage correlation based on the TMI data, where sizing was obtained using qualified techniques. There were 25 indications in SG A and 11 indications in SG B that had no signal present based on a review of the first ISI data (1R20).
Eight new indications in SG A and three new indications in SG B were detected during 1R21 and repeated during 1R23. The reanalysis of the bobbin data shows that the mechanism of tube-to-tube wear is active at ANO-1, as well as TMI. It also illustrates that indications do not occur only in the first cycle and then remain unchanged over subsequent operating periods.
However, the 1R23 depth sizes demonstrate that the indications were not significantly active.
The two indications with the largest depths (26% TW in SG B) were essentially unchanged
Enclosure to 1CAN031203 Page 13 of 13 from 1R21. There were two locations in SG A that showed two wear scars approximately 60 degrees apart on the array data. There were six locations in SG B with two wear scars and two locations with three wear scars, all approximately 60 degrees apart on the array data.
The reported depth was the total depth for the two wear scars based on the bobbin correlation. Attachment 1 is the listing of indications in SG A and Attachment 2 is the listing of indications in SG B.
to the Enclosure to 1CAN031203 Page 1 of 2 SG A Tube-to-Tube Wear Item Row Tube
%TW Tube Support Plate Elevation (Inches) 1 74 110 16 8
18.29 2
81 111 15 8
18.43 3
74 109 13 8
18.02 4
62 29 13 8
18.87 5
61 30 12 8
19.02 6
91 108 12 7
18.91 7
71 110 11 8
18.60 8
77 109 11 8
18.05 9
90 106 11 7
19.13 10 72 110 10 8
18.51 11 81 110 10 8
18.16 12 75 109 10 8
18.42 13 43 22 9
8 19.03 14 81 21 9
8 18.49 15 117 35 9
8 18.55 16 121 73 9
8 17.43 17 119 44 9
8 18.45 18 82 110 9
8 18.66 19 72 108 9
8 18.55 20 75 108 9
8 18.37 21 118 35 9
8 18.56 22 119 70 9
8 18.50 23 127 51 8
8 18.07 24 126 52 8
8 17.37 25 72 107 8
8 18.57 26 119 71 8
8 18.72 27 120 73 8
8 17.70 28 77 108 8
8 16.95 29 118 87 8
8 18.83 30 83 31 7
8 18.41 31 124 62 7
6 20.25 32 124 63 7
6 20.10 33 78 21 7
8 17.79 to the Enclosure to 1CAN031203 Page 2 of 2 Item Row Tube
%TW Tube Support Plate Elevation (Inches) 34 99 101 7
8 18.34 35 46 89 7
8 18.50 36 82 20 7
8 18.08 37 107 88 7
8 18.56 38 82 111 7
7 21.17 39 42 22 7
8 18.99 40 74 22 7
8 18.58 41 77 25 7
8 18.73 42 100 100 7
8 18.18 43 118 90 6
7 20.22 44 119 84 6
7 19.84 45 107 87 6
8 18.31 46 71 109 6
8 18.43 47 77 22 6
8 17.28 48 82 31 6
8 18.84 to the Enclosure to 1CAN031203 Page 1 of 3 SG B Tube-to-Tube Wear Item Row Tube
%TW Tube Support Plate Elevation (Inches) 1 116 29 26 7
20.62 2
117 29 26 7
20.80 3
119 25 16 7
20.95 4
28 77 15 8
17.94 5
46 100 15 8
18.70 6
120 25 14 7
20.74 7
25 72 14 8
17.83 8
31 34 13 8
18.58 9
28 76 13 8
18.12 10 21 51 13 7
19.95 11 47 99 13 8
18.69 12 115 31 13 8
18.28 13 21 50 12 7
20.04 14 114 83 11 8
19.34 15 115 30 11 8
18.08 16 25 71 11 8
18.28 17 31 35 10 8
18.93 18 20 52 10 8
19.00 19 22 63 10 8
18.47 20 29 77 10 8
18.83 21 26 39 10 8
18.61 22 22 49 10 8
18.78 23 31 63 10 8
19.72 24 20 51 10 8
18.75 25 68 110 10 8
18.33 26 90 25 10 8
18.80 27 114 82 10 8
18.89 28 31 62 10 8
19.04 29 22 62 9
8 18.66 30 28 68 9
7 20.73 31 22 51 9
8 18.99 32 34 27 9
8 19.28 33 38 86 9
8 19.94 to the Enclosure to 1CAN031203 Page 2 of 3 Item Row Tube
%TW Tube Support Plate Elevation (Inches) 34 38 87 9
8 19.63 35 21 47 9
8 18.49 36 119 29 9
7 19.83 37 28 69 9
8 18.47 38 89 25 9
8 18.42 39 34 56 9
8 19.21 40 40 36 8
8 18.38 41 21 50 8
8 19.07 42 28 67 8
7 20.79 43 67 108 8
8 18.89 44 129 30 8
8 17.80 45 27 69 8
8 17.86 46 34 90 8
8 18.03 47 39 92 8
8 20.72 48 46 21 8
8 18.64 49 26 72 8
8 18.09 50 28 68 8
8 18.63 51 75 114 8
8 18.89 52 39 37 7
8 18.39 53 103 21 7
8 17.80 54 118 88 7
8 18.55 55 78 20 7
8 18.78 56 34 55 7
8 19.08 57 35 28 7
8 19.01 58 106 24 7
8 18.94 59 119 28 7
7 19.98 60 31 74 7
8 18.38 61 47 21 7
8 18.47 62 123 32 7
8 18.66 63 32 74 7
8 18.85 64 58 26 7
8 19.37 65 103 22 7
8 17.79 66 128 45 7
7 20.65 67 44 25 7
8 19.36 68 105 23 7
8 19.29 to the Enclosure to 1CAN031203 Page 3 of 3 Item Row Tube
%TW Tube Support Plate Elevation (Inches) 69 23 59 6
8 18.28 70 128 60 6
8 18.98 71 31 62 6
7 20.09 72 60 21 6
8 18.84 73 34 89 6
8 18.18 74 118 28 6
8 18.67 75 31 38 6
8 18.52 76 39 91 6
8 19.52 77 102 102 6
8 17.59 78 128 45 5
8 18.65 to the Enclosure to 1CAN031203 Page 1 of 42 SG A Tube Support Plate (TSP) Wear Item Row Tube
%TW TSP Elevation (Inches) 1 147 8
32 10S
-0.69 2
140 14 30 10S
-0.67 3
11 12 28 10S
-0.62 4
23 86 28 10S
-0.84 5
142 13 27 10S
-0.71 6
140 9
26 10S
-0.69 7
141 11 26 10S
-0.69 8
7 10 25 10S
-0.6 9
21 90 25 12S
-0.81 10 142 12 25 10S
-0.69 11 75 109 24 06S 0.43 12 29 97 23 12S 0.26 13 65 107 23 10S
-0.77 14 65 107 23 10S 0.28 15 12 11 22 10S
-0.62 16 17 5
22 10S
-0.61 17 116 5
22 09S 0.46 18 10 9
21 10S
-0.6 19 13 13 21 10S
-0.63 20 23 94 21 12S
-0.84 21 77 132 21 10S 0.31 22 120 4
21 10S
-0.59 23 129 9
21 09S 0.47 24 147 7
21 10S
-0.69 25 5
29 20 10S 0.06 26 8
17 20 09S
-0.68 27 9
9 20 10S
-0.61 28 10 12 20 10S
-0.67 29 15 80 20 13S
-0.86 30 23 85 20 10S
-0.82 31 24 83 20 10S
-0.8 32 71 105 20 06S
-0.64 to the Enclosure to 1CAN031203 Page 2 of 42 Item Row Tube
%TW TSP Elevation (Inches) 33 108 28 20 08S
-0.71 34 146 10 20 10S
-0.73 35 146 15 20 10S
-0.74 36 148 13 20 10S
-0.74 37 140 15 19 10S
-0.73 38 8
16 18 09S
-0.67 39 9
12 18 10S
-0.65 40 11 1
18 13S 0.54 41 11 13 18 10S
-0.69 42 55 122 18 09S
-0.73 43 75 108 18 06S
-0.66 44 106 119 18 10S
-0.84 45 142 53 18 11S 0.37 46 5
20 17 10S
-0.68 47 5
28 17 10S 0.17 48 8
19 17 09S
-0.66 49 10 3
17 13S 0.48 50 11 8
17 10S
-0.58 51 12 8
17 12S
-0.63 52 76 102 17 06S
-0.69 53 84 22 17 08S
-0.6 54 139 16 17 10S
-0.67 55 147 6
17 10S
-0.67 56 6
15 16 10S
-0.66 57 12 8
16 13S 0.52 58 55 23 16 08S
-0.66 59 55 122 16 11S 0.34 60 57 105 16 08S
-0.66 61 70 104 16 09S
-0.64 62 71 107 16 08S
-0.75 63 72 106 16 08S
-0.73 64 73 25 16 08S
-0.61 65 75 26 16 08S
-0.6 66 77 2
16 11S 0.57 67 81 111 16 06S
-0.71 to the Enclosure to 1CAN031203 Page 3 of 42 Item Row Tube
%TW TSP Elevation (Inches) 68 103 29 16 08S
-0.7 69 132 8
16 09S 0.48 70 134 7
16 10S
-0.66 71 139 15 16 10S
-0.69 72 140 7
16 10S
-0.67 73 143 53 16 11S 0.39 74 4
25 15 10S 0.11 75 6
6 15 10S
-0.58 76 6
31 15 12S
-0.76 77 8
20 15 09S
-0.6 78 8
39 15 12S
-0.82 79 10 10 15 10S
-0.6 80 12 7
15 10S
-0.58 81 13 16 15 10S
-0.67 82 24 91 15 12S
-0.81 83 27 94 15 12S
-0.79 84 40 92 15 08S 0.38 85 43 24 15 08S
-0.62 86 50 96 15 08S
-0.73 87 55 119 15 11S 0.37 88 60 124 15 11S 0.34 89 61 125 15 11S 0.3 90 64 103 15 10S
-0.81 91 65 21 15 08S
-0.64 92 66 108 15 08S 0.45 93 71 105 15 09S
-0.7 94 93 22 15 08S
-0.61 95 107 6
15 09S
-0.6 96 111 29 15 08S
-0.69 97 115 29 15 08S
-0.66 98 134 79 15 11S 0.36 99 139 14 15 10S
-0.69 100 140 13 15 10S
-0.74 101 143 52 15 11S 0.41 102 6
19 14 10S
-0.71 to the Enclosure to 1CAN031203 Page 4 of 42 Item Row Tube
%TW TSP Elevation (Inches) 103 6
31 14 09S
-0.69 104 9
43 14 09S
-0.71 105 12 9
14 10S
-0.6 106 13 12 14 10S
-0.61 107 19 80 14 09S
-0.73 108 20 82 14 12S 0.34 109 22 85 14 10S
-0.72 110 27 95 14 12S
-0.85 111 28 96 14 12S 0.3 112 36 69 14 08S 0.43 113 37 86 14 08S 0.45 114 47 88 14 08S
-0.77 115 49 102 14 07S 0.45 116 55 122 14 09S 0.41 117 65 103 14 06S
-0.66 118 66 106 14 08S
-0.73 119 72 25 14 08S
-0.61 120 75 108 14 09S
-0.75 121 76 102 14 10S
-0.82 122 77 109 14 08S
-0.74 123 91 25 14 08S
-0.65 124 98 4
14 09S 0.51 125 98 24 14 08S
-0.64 126 121 8
14 09S 0.47 127 127 98 14 13S
-0.86 128 128 1
14 13S 0.49 129 136 6
14 10S
-0.62 130 138 19 14 10S
-0.73 131 139 12 14 10S
-0.67 132 140 11 14 10S
-0.71 133 141 60 14 11S 0.41 134 144 18 14 09S 0.41 135 5
26 13 12S
-0.82 136 7
17 13 10S
-0.69 137 9
11 13 13S
-0.69 to the Enclosure to 1CAN031203 Page 5 of 42 Item Row Tube
%TW TSP Elevation (Inches) 138 11 11 13 10S
-0.58 139 11 14 13 10S
-0.49 140 12 13 13 10S
-0.65 141 13 11 13 10S
-0.63 142 19 82 13 10S 0.21 143 20 89 13 12S
-0.79 144 22 86 13 12S
-0.79 145 26 93 13 12S
-0.81 146 35 86 13 08S 0.45 147 36 89 13 08S 0.43 148 38 89 13 08S 0.43 149 40 91 13 08S 0.43 150 45 20 13 08S
-0.59 151 46 23 13 08S
-0.62 152 48 104 13 07S
-0.71 153 52 118 13 10S
-0.79 154 71 23 13 08S
-0.66 155 71 25 13 08S
-0.61 156 74 108 13 09S
-0.75 157 74 110 13 10S
-0.85 158 76 123 13 11S 0.32 159 77 132 13 10S
-0.77 160 83 23 13 08S
-0.59 161 93 23 13 08S
-0.62 162 93 24 13 08S
-0.63 163 98 8
13 09S 0.55 164 101 23 13 08S
-0.65 165 107 26 13 08S
-0.67 166 108 30 13 08S
-0.64 167 109 24 13 08S
-0.67 168 114 36 13 08S
-0.71 169 115 110 13 10S 0.02 170 120 78 13 08S 0.55 171 122 7
13 10S
-0.63 172 122 52 13 08S
-0.76 173 128 83 13 09S 0.4 to the Enclosure to 1CAN031203 Page 6 of 42 Item Row Tube
%TW TSP Elevation (Inches) 174 139 11 13 10S
-0.69 175 142 14 13 10S
-0.69 176 147 5
13 10S
-0.71 177 3
5 12 13S
-0.63 178 4
6 12 13S
-0.72 179 6
9 12 10S
-0.64 180 7
14 12 10S
-0.62 181 7
21 12 09S
-0.68 182 7
32 12 09S
-0.67 183 7
33 12 09S
-0.65 184 9
31 12 12S
-0.83 185 10 62 12 14S 0.26 186 11 11 12 13S 0.43 187 11 64 12 10S
-0.02 188 12 8
12 10S
-0.59 189 14 15 12 10S
-0.58 190 14 74 12 10S
-0.02 191 15 19 12 10S
-0.71 192 17 76 12 15S
-0.89 193 18 77 12 09S 0.41 194 18 78 12 09S
-0.75 195 22 88 12 12S
-0.79 196 22 92 12 12S
-0.77 197 29 71 12 08S 0.4 198 29 98 12 12S 0.34 199 31 100 12 10S 0.13 200 37 39 12 08S
-0.73 201 37 85 12 08S 0.43 202 37 87 12 08S 0.38 203 40 19 12 08S
-0.67 204 40 25 12 08S
-0.64 205 40 27 12 08S
-0.6 206 41 27 12 08S
-0.62 207 41 28 12 08S
-0.64 208 53 121 12 12S 0.3 209 54 119 12 10S
-0.75 to the Enclosure to 1CAN031203 Page 7 of 42 Item Row Tube
%TW TSP Elevation (Inches) 210 60 23 12 08S
-0.55 211 60 24 12 08S
-0.62 212 60 108 12 08S 0.45 213 62 98 12 08S 0.34 214 64 104 12 08S 0.45 215 64 105 12 08S
-0.73 216 66 22 12 08S
-0.64 217 70 103 12 08S 0.45 218 70 104 12 06S
-0.55 219 71 103 12 08S
-0.75 220 72 22 12 08S
-0.62 221 72 125 12 11S 0.23 222 74 109 12 08S
-0.73 223 74 110 12 06S
-0.7 224 75 105 12 07S 0.47 225 78 115 12 07S
-0.63 226 83 20 12 08S
-0.58 227 84 23 12 08S
-0.64 228 91 24 12 08S
-0.64 229 92 23 12 08S
-0.6 230 92 24 12 08S
-0.61 231 94 24 12 08S
-0.63 232 107 29 12 08S
-0.66 233 108 26 12 08S
-0.61 234 111 30 12 08S
-0.66 235 115 4
12 10S
-0.62 236 115 27 12 08S
-0.62 237 117 107 12 10S 0.09 238 119 30 12 08S
-0.68 239 119 44 12 07S 0.47 240 119 60 12 08S
-0.74 241 125 93 12 10S
-0.77 242 134 1
12 14S
-0.61 243 141 14 12 09S 0.44 244 141 15 12 09S 0.44 245 143 10 12 10S
-0.67 to the Enclosure to 1CAN031203 Page 8 of 42 Item Row Tube
%TW TSP Elevation (Inches) 246 144 7
12 10S
-0.71 247 147 13 12 10S
-0.71 248 147 15 12 10S
-0.76 249 5
23 11 10S
-0.65 250 5
25 11 12S
-0.8 251 5
26 11 13S 0.37 252 5
27 11 12S
-0.76 253 7
9 11 10S
-0.64 254 7
32 11 12S 0.35 255 7
34 11 12S
-0.78 256 7
35 11 12S
-0.8 257 8
35 11 09S 0.41 258 10 1
11 13S 0.52 259 14 16 11 10S
-0.69 260 14 77 11 13S
-0.9 261 15 16 11 10S
-0.65 262 16 74 11 09S 0.39 263 17 68 11 10S
-0.77 264 18 7
11 12S
-0.67 265 22 85 11 09S
-0.72 266 23 89 11 12S 0.39 267 24 85 11 12S
-0.82 268 25 59 11 08S
-0.71 269 27 51 11 08S
-0.76 270 28 41 11 08S
-0.67 271 31 70 11 08S 0.45 272 35 63 11 08S
-0.71 273 36 24 11 08S
-0.6 274 37 108 11 12S 0.3 275 38 27 11 08S
-0.67 276 40 23 11 08S
-0.6 277 41 26 11 08S
-0.62 278 41 29 11 08S
-0.57 279 43 21 11 08S
-0.62 280 44 24 11 08S
-0.62 281 45 24 11 09S
-0.64 to the Enclosure to 1CAN031203 Page 9 of 42 Item Row Tube
%TW TSP Elevation (Inches) 282 49 17 11 08S
-0.55 283 49 102 11 10S
-0.83 284 51 7
11 10S 0.19 285 51 18 11 08S
-0.62 286 51 112 11 10S
-0.82 287 53 22 11 08S
-0.64 288 54 23 11 08S
-0.66 289 54 24 11 08S
-0.59 290 54 109 11 08S 0.41 291 56 23 11 08S
-0.57 292 59 124 11 11S 0.32 293 62 122 11 09S 0.38 294 63 22 11 08S
-0.66 295 64 22 11 08S
-0.58 296 65 26 11 08S
-0.68 297 65 110 11 10S 0.29 298 67 23 11 08S
-0.64 299 67 26 11 08S
-0.63 300 67 29 11 08S
-0.67 301 67 124 11 11S 0.28 302 68 22 11 08S
-0.57 303 73 104 11 06S
-0.66 304 73 107 11 10S
-0.81 305 73 109 11 08S
-0.75 306 74 109 11 07S 0.47 307 75 21 11 08S
-0.57 308 75 105 11 08S
-0.64 309 75 108 11 08S
-0.64 310 79 28 11 08S
-0.6 311 79 111 11 08S 0.43 312 81 115 11 08S 0.45 313 83 18 11 08S
-0.49 314 97 21 11 08S
-0.57 315 97 23 11 08S
-0.59 316 99 24 11 08S
-0.65 317 99 119 11 09S 0.38 to the Enclosure to 1CAN031203 Page 10 of 42 Item Row Tube
%TW TSP Elevation (Inches) 318 103 9
11 09S
-0.57 319 103 9
11 09S 0.5 320 113 28 11 08S
-0.64 321 113 30 11 08S
-0.68 322 118 68 11 08S
-0.71 323 120 64 11 08S
-0.72 324 122 1
11 10S 0.46 325 123 54 11 08S
-0.74 326 127 41 11 08S 0.43 327 128 2
11 12S
-0.64 328 130 9
11 09S 0.48 329 130 45 11 08S
-0.73 330 133 81 11 11S 0.36 331 137 8
11 09S 0.5 332 140 1
11 13S
-0.72 333 141 59 11 11S 0.39 334 142 57 11 11S 0.39 335 148 11 11 10S
-0.74 336 5
18 10 12S
-0.79 337 6
20 10 09S
-0.67 338 6
29 10 09S
-0.67 339 6
30 10 13S
-0.82 340 6
32 10 12S
-0.8 341 7
13 10 10S
-0.66 342 8
11 10 10S
-0.64 343 8
41 10 09S
-0.71 344 9
57 10 13S
-0.81 345 10 15 10 10S
-0.61 346 10 56 10 14S 0.26 347 12 2
10 13S 0.59 348 12 57 10 15S
-0.85 349 13 61 10 12S
-0.84 350 14 11 10 10S
-0.63 351 17 76 10 09S
-0.67 352 21 84 10 12S
-0.84 353 22 85 10 11S 0.34 to the Enclosure to 1CAN031203 Page 11 of 42 Item Row Tube
%TW TSP Elevation (Inches) 354 23 87 10 12S
-0.81 355 24 90 10 12S
-0.87 356 27 46 10 08S
-0.69 357 27 66 10 08S 0.49 358 27 102 10 10S
-0.76 359 29 34 10 08S
-0.65 360 29 42 10 08S
-0.74 361 29 98 10 12S
-0.81 362 31 75 10 08S 0.43 363 32 100 10 10S 0.15 364 33 77 10 08S 0.4 365 33 78 10 08S 0.43 366 34 103 10 10S
-0.79 367 35 107 10 10S 0.21 368 36 84 10 08S 0.47 369 39 27 10 08S 0.54 370 39 89 10 08S 0.42 371 40 87 10 08S
-0.72 372 40 89 10 08S 0.49 373 41 23 10 08S
-0.66 374 43 20 10 08S
-0.6 375 43 25 10 08S
-0.64 376 46 24 10 08S
-0.64 377 47 94 10 08S
-0.77 378 47 113 10 10S
-0.8 379 47 118 10 14S 0.19 380 48 27 10 08S
-0.59 381 50 92 10 08S 0.47 382 53 123 10 14S 0.24 383 54 22 10 08S
-0.62 384 54 106 10 08S 0.45 385 55 101 10 08S
-0.77 386 56 20 10 08S
-0.64 387 57 21 10 08S
-0.58 388 58 21 10 08S
-0.56 389 58 125 10 12S
-0.84 to the Enclosure to 1CAN031203 Page 12 of 42 Item Row Tube
%TW TSP Elevation (Inches) 390 59 20 10 08S
-0.62 391 62 98 10 08S
-0.81 392 65 110 10 07S 0.42 393 67 2
10 13S 0.59 394 67 22 10 08S
-0.62 395 67 105 10 07S 0.51 396 67 105 10 09S
-0.69 397 71 24 10 08S
-0.61 398 71 104 10 08S
-0.73 399 71 105 10 08S 0.41 400 71 105 10 10S
-0.81 401 72 1
10 13S
-0.55 402 72 107 10 08S
-0.72 403 73 104 10 09S
-0.77 404 74 104 10 08S
-0.72 405 75 28 10 08S
-0.66 406 75 30 10 08S
-0.64 407 75 107 10 08S 0.43 408 77 109 10 08S 0.32 409 77 112 10 08S 0.43 410 81 18 10 08S
-0.51 411 83 24 10 08S
-0.62 412 84 18 10 08S
-0.6 413 84 125 10 09S 0.36 414 89 23 10 08S
-0.64 415 89 24 10 08S 0.53 416 91 22 10 08S
-0.66 417 92 21 10 08S
-0.6 418 94 111 10 07S
-0.65 419 96 23 10 08S
-0.59 420 99 26 10 08S
-0.61 421 101 111 10 09S 0.42 422 102 9
10 09S 0.52 423 104 9
10 09S
-0.62 424 104 30 10 08S
-0.65 425 106 5
10 10S 0.48 to the Enclosure to 1CAN031203 Page 13 of 42 Item Row Tube
%TW TSP Elevation (Inches) 426 106 23 10 08S
-0.69 427 106 25 10 08S
-0.67 428 106 31 10 08S
-0.66 429 108 25 10 08S
-0.62 430 110 28 10 08S
-0.68 431 111 27 10 08S
-0.65 432 111 89 10 08S 0.34 433 112 27 10 08S
-0.66 434 112 95 10 08S 0.45 435 114 31 10 08S
-0.7 436 115 71 10 08S
-0.72 437 116 28 10 08S
-0.64 438 117 62 10 08S
-0.74 439 119 6
10 09S 0.54 440 119 31 10 08S
-0.71 441 119 56 10 08S
-0.68 442 120 40 10 08S
-0.73 443 122 35 10 08S
-0.69 444 124 9
10 09S 0.47 445 124 49 10 08S
-0.75 446 126 7
10 10S
-0.66 447 126 24 10 10S
-0.73 448 126 50 10 08S
-0.75 449 131 84 10 10S 0.02 450 134 2
10 10S
-0.63 451 134 6
10 10S
-0.63 452 135 8
10 10S
-0.66 453 136 7
10 10S
-0.65 454 137 12 10 09S 0.48 455 138 15 10 10S
-0.73 456 140 61 10 11S 0.41 457 140 62 10 11S
-0.77 458 142 11 10 10S
-0.71 459 144 47 10 11S 0.43 460 146 16 10 10S
-0.76 461 1
19 9
10S 0.47 to the Enclosure to 1CAN031203 Page 14 of 42 Item Row Tube
%TW TSP Elevation (Inches) 462 5
27 9
10S
-0.65 463 6
41 9
09S 0.45 464 9
12 9
09S 0.49 465 9
17 9
09S 0.47 466 9
54 9
14S 0.28 467 10 36 9
15S 0.24 468 11 50 9
15S 0.28 469 12 15 9
10S
-0.62 470 13 10 9
10S
-0.61 471 13 17 9
09S
-0.62 472 13 60 9
09S 0.45 473 15 15 9
11S
-0.69 474 19 66 9
09S
-0.73 475 24 48 9
08S
-0.69 476 24 85 9
10S 0.19 477 25 82 9
15S
-0.89 478 26 65 9
08S
-0.69 479 27 39 9
08S 0.5 480 28 41 9
08S 0.48 481 28 42 9
08S
-0.67 482 28 96 9
12S
-0.85 483 29 32 9
08S
-0.63 484 29 66 9
08S 0.49 485 29 72 9
08S 0.45 486 29 73 9
08S 0.47 487 29 99 9
12S
-0.87 488 30 33 9
08S
-0.69 489 30 99 9
12S
-0.85 490 31 34 9
08S
-0.67 491 31 37 9
08S
-0.72 492 31 100 9
12S 0.3 493 32 29 9
08S
-0.53 494 32 97 9
10S
-0.77 495 32 102 9
14S 0.22 496 33 67 9
08S
-0.72 497 33 71 9
08S 0.45 to the Enclosure to 1CAN031203 Page 15 of 42 Item Row Tube
%TW TSP Elevation (Inches) 498 33 75 9
08S 0.47 499 33 76 9
08S 0.45 500 35 62 9
08S
-0.71 501 35 76 9
08S 0.47 502 35 82 9
08S 0.43 503 35 83 9
08S 0.47 504 36 87 9
08S 0.43 505 37 88 9
08S 0.45 506 38 20 9
08S 0.54 507 38 26 9
08S
-0.64 508 39 113 9
14S 0.26 509 40 24 9
08S
-0.58 510 40 28 9
08S
-0.66 511 41 24 9
08S
-0.66 512 43 27 9
08S
-0.64 513 44 95 9
08S 0.47 514 45 15 9
08S
-0.58 515 45 20 9
09S
-0.64 516 45 25 9
08S
-0.66 517 45 97 9
08S 0.43 518 45 115 9
12S
-0.84 519 46 117 9
12S
-0.82 520 48 4
9 11S
-0.6 521 49 93 9
08S 0.45 522 49 115 9
10S
-0.77 523 52 18 9
08S
-0.53 524 53 20 9
08S
-0.62 525 54 19 9
08S 0.51 526 54 20 9
08S
-0.57 527 54 21 9
08S
-0.64 528 54 21 9
08S 0.56 529 54 109 9
08S
-0.71 530 54 121 9
11S 0.37 531 54 123 9
12S
-0.79 532 56 20 9
08S 0.51 533 56 118 9
11S
-0.85 to the Enclosure to 1CAN031203 Page 16 of 42 Item Row Tube
%TW TSP Elevation (Inches) 534 57 27 9
08S
-0.66 535 57 107 9
10S
-0.81 536 58 22 9
08S
-0.62 537 58 23 9
08S
-0.6 538 58 104 9
07S 0.45 539 59 106 9
08S
-0.75 540 60 125 9
12S
-0.85 541 63 111 9
08S 0.45 542 64 106 9
08S 0.43 543 67 25 9
08S
-0.62 544 67 125 9
09S 0.45 545 69 27 9
08S
-0.66 546 69 102 9
08S
-0.77 547 70 20 9
08S
-0.56 548 70 25 9
08S
-0.62 549 70 26 9
08S
-0.55 550 70 28 9
08S
-0.63 551 70 104 9
07S 0.49 552 71 5
9 09S
-0.53 553 71 26 9
08S
-0.63 554 71 32 9
08S
-0.63 555 71 107 9
08S 0.38 556 72 103 9
08S 0.49 557 73 17 9
08S
-0.6 558 73 18 9
08S
-0.55 559 73 105 9
08S 0.49 560 73 110 9
09S
-0.74 561 74 39 9
08S
-0.7 562 74 108 9
08S 0.47 563 75 109 9
07S 0.47 564 75 109 9
08S 0.45 565 76 28 9
08S
-0.66 566 76 110 9
08S 0.41 567 76 111 9
08S 0.43 568 78 103 9
08S 0.47 569 78 111 9
08S
-0.72 to the Enclosure to 1CAN031203 Page 17 of 42 Item Row Tube
%TW TSP Elevation (Inches) 570 79 113 9
08S 0.45 571 83 26 9
08S
-0.62 572 84 24 9
08S
-0.6 573 84 111 9
08S 0.42 574 89 22 9
08S 0.55 575 92 22 9
08S
-0.61 576 95 25 9
08S
-0.61 577 96 26 9
08S
-0.66 578 96 107 9
08S 0.44 579 97 26 9
08S
-0.64 580 98 22 9
08S
-0.61 581 99 8
9 09S 0.57 582 99 20 9
08S
-0.61 583 99 25 9
08S
-0.64 584 99 114 9
09S
-0.7 585 99 117 9
09S 0.4 586 100 25 9
08S
-0.57 587 103 5
9 10S
-0.57 588 104 8
9 09S 0.55 589 104 27 9
08S
-0.64 590 104 31 9
08S
-0.64 591 107 88 9
08S 0.43 592 108 5
9 09S
-0.55 593 108 21 9
08S
-0.62 594 110 26 9
08S
-0.64 595 110 31 9
08S
-0.69 596 110 83 9
08S
-0.72 597 111 20 9
08S
-0.64 598 111 25 9
08S
-0.65 599 112 32 9
08S
-0.71 600 113 26 9
08S
-0.66 601 115 109 9
10S 0.11 602 120 80 9
08S 0.45 603 120 101 9
10S 0.13 604 121 54 9
08S
-0.77 605 121 56 9
08S
-0.71 to the Enclosure to 1CAN031203 Page 18 of 42 Item Row Tube
%TW TSP Elevation (Inches) 606 121 65 9
08S
-0.74 607 122 8
9 09S 0.49 608 122 34 9
08S
-0.7 609 122 40 9
09S
-0.72 610 122 61 9
08S
-0.74 611 126 42 9
08S
-0.79 612 126 46 9
08S 0.46 613 127 50 9
08S
-0.73 614 130 2
9 13S 0.47 615 130 8
9 10S
-0.66 616 131 8
9 09S 0.49 617 132 7
9 10S
-0.6 618 135 9
9 09S 0.46 619 139 57 9
09S
-0.53 620 141 9
9 10S
-0.69 621 145 3
9 11S
-0.71 622 148 22 9
10S 0.39 623 3
23 8
10S 0.09 624 5
19 8
10S
-0.65 625 5
19 8
12S
-0.76 626 6
17 8
10S
-0.69 627 6
19 8
12S
-0.75 628 6
21 8
12S
-0.79 629 6
30 8
12S
-0.78 630 6
32 8
10S
-0.67 631 8
39 8
09S
-0.68 632 8
39 8
15S
-0.86 633 8
49 8
14S
-0.89 634 10 57 8
14S 0.35 635 10 60 8
10S
-0.09 636 11 2
8 14S
-0.69 637 11 8
8 12S
-0.67 638 11 10 8
10S
-0.62 639 11 27 8
15S 0.28 640 11 52 8
10S
-0.79 641 11 55 8
09S 0.42 to the Enclosure to 1CAN031203 Page 19 of 42 Item Row Tube
%TW TSP Elevation (Inches) 642 11 59 8
14S 0.26 643 12 1
8 13S 0.52 644 12 12 8
10S
-0.61 645 13 1
8 13S 0.52 646 13 14 8
10S
-0.59 647 13 57 8
09S
-0.67 648 13 59 8
12S
-0.84 649 13 67 8
14S 0.26 650 14 15 8
11S
-0.65 651 14 17 8
07S
-0.56 652 15 72 8
09S
-0.71 653 16 61 8
15S
-0.89 654 18 80 8
10S 0.13 655 19 71 8
12S 0.34 656 20 85 8
14S 0.24 657 21 87 8
12S
-0.79 658 23 88 8
12S
-0.8 659 23 93 8
12S
-0.81 660 24 38 8
08S 0.47 661 24 86 8
10S 0.15 662 25 54 8
08S 0.45 663 25 62 8
08S 0.45 664 26 29 8
08S
-0.67 665 26 33 8
08S
-0.67 666 26 49 8
08S
-0.69 667 26 99 8
12S
-0.77 668 27 32 8
08S
-0.59 669 27 38 8
08S
-0.65 670 27 45 8
08S
-0.54 671 27 64 8
08S 0.44 672 28 31 8
08S 0.52 673 28 40 8
08S
-0.71 674 28 41 8
09S
-0.72 675 28 46 8
08S
-0.73 676 28 57 8
08S
-0.69 677 28 97 8
12S
-0.83 to the Enclosure to 1CAN031203 Page 20 of 42 Item Row Tube
%TW TSP Elevation (Inches) 678 29 31 8
08S
-0.65 679 29 34 8
08S 0.52 680 29 61 8
08S 0.47 681 30 31 8
08S
-0.63 682 30 32 8
08S
-0.68 683 30 34 8
08S
-0.67 684 30 73 8
08S 0.47 685 30 100 8
12S
-0.81 686 31 32 8
08S
-0.65 687 31 38 8
08S
-0.63 688 31 57 8
08S
-0.71 689 31 68 8
08S 0.47 690 32 25 8
08S
-0.65 691 32 73 8
08S 0.45 692 32 98 8
12S
-0.77 693 32 99 8
12S 0.28 694 32 100 8
14S 0.24 695 33 29 8
08S
-0.66 696 33 72 8
08S 0.47 697 33 80 8
08S
-0.75 698 33 103 8
12S
-0.85 699 34 6
8 12S
-0.65 700 35 21 8
08S
-0.59 701 35 84 8
08S 0.45 702 35 106 8
11S 0.37 703 35 107 8
14S 0.26 704 36 19 8
08S 0.52 705 36 25 8
08S
-0.62 706 36 30 8
08S
-0.69 707 36 78 8
08S 0.49 708 37 7
8 10S 0.56 709 37 24 8
08S 0.52 710 37 77 8
08S 0.4 711 38 23 8
08S
-0.62 712 38 25 8
08S
-0.64 713 38 29 8
08S
-0.66 to the Enclosure to 1CAN031203 Page 21 of 42 Item Row Tube
%TW TSP Elevation (Inches) 714 38 88 8
08S 0.38 715 38 110 8
11S 0.34 716 38 111 8
10S
-0.73 717 39 111 8
12S
-0.89 718 41 21 8
08S
-0.62 719 41 22 8
08S
-0.64 720 41 93 8
08S 0.41 721 42 5
8 10S 0.54 722 42 22 8
08S
-0.62 723 42 24 8
08S
-0.62 724 42 26 8
08S
-0.66 725 42 87 8
08S 0.49 726 44 96 8
08S 0.45 727 44 97 8
08S 0.43 728 45 96 8
08S 0.49 729 46 26 8
08S
-0.62 730 47 17 8
08S
-0.6 731 47 21 8
08S
-0.64 732 49 91 8
08S 0.49 733 49 100 8
08S 0.49 734 51 104 8
08S 0.43 735 52 16 8
08S
-0.57 736 52 107 8
08S 0.43 737 53 19 8
08S
-0.6 738 53 26 8
08S
-0.64 739 55 19 8
08S
-0.57 740 55 101 8
08S 0.41 741 55 104 8
08S
-0.73 742 56 7
8 10S 0.56 743 57 107 8
09S
-0.7 744 58 21 8
08S 0.56 745 58 33 8
08S
-0.64 746 59 105 8
08S
-0.73 747 60 103 8
08S 0.43 748 61 22 8
08S
-0.57 749 61 23 8
08S
-0.63 to the Enclosure to 1CAN031203 Page 22 of 42 Item Row Tube
%TW TSP Elevation (Inches) 750 63 110 8
08S 0.45 751 64 106 8
06S 0.45 752 66 123 8
10S 0.34 753 67 105 8
10S 0.39 754 68 24 8
08S
-0.59 755 68 26 8
08S
-0.66 756 68 31 8
08S
-0.7 757 68 126 8
09S 0.42 758 69 4
8 10S 0.28 759 69 126 8
11S 0.34 760 70 4
8 10S 0.25 761 71 105 8
07S 0.47 762 72 24 8
08S
-0.63 763 73 115 8
07S 0.46 764 74 27 8
08S
-0.62 765 74 110 8
05S
-0.66 766 75 22 8
08S
-0.64 767 75 111 8
08S 0.4 768 75 113 8
06S
-0.62 769 77 109 8
09S
-0.74 770 78 17 8
08S
-0.52 771 78 107 8
08S
-0.74 772 79 23 8
08S
-0.55 773 80 5
8 09S 0.56 774 81 23 8
08S 0.55 775 81 111 8
05S
-0.75 776 81 124 8
09S
-0.69 777 82 19 8
08S
-0.6 778 82 84 8
04S 0.61 779 82 117 8
08S 0.4 780 83 29 8
08S
-0.61 781 84 6
8 09S 0.55 782 84 17 8
08S
-0.55 783 84 22 8
08S 0.49 784 84 116 8
08S 0.45 785 84 116 8
09S
-0.71 to the Enclosure to 1CAN031203 Page 23 of 42 Item Row Tube
%TW TSP Elevation (Inches) 786 85 29 8
08S
-0.63 787 86 22 8
08S 0.58 788 86 78 8
09S 0.55 789 88 23 8
08S 0.55 790 89 23 8
08S 0.53 791 91 21 8
08S
-0.61 792 91 127 8
10S 0.08 793 93 25 8
08S
-0.68 794 94 111 8
08S 0.44 795 95 21 8
08S
-0.53 796 97 22 8
08S
-0.64 797 97 24 8
08S
-0.66 798 97 26 8
08S 0.53 799 98 5
8 10S
-0.53 800 99 9
8 09S 0.51 801 99 23 8
08S
-0.7 802 99 23 8
08S 0.47 803 99 25 8
08S 0.55 804 100 8
8 10S
-0.64 805 101 1
8 13S
-0.61 806 103 19 8
08S
-0.61 807 104 8
8 09S
-0.52 808 106 27 8
08S
-0.65 809 106 98 8
08S
-0.78 810 107 5
8 09S 0.5 811 107 115 8
10S
-0.78 812 108 31 8
08S
-0.69 813 109 29 8
08S
-0.66 814 110 30 8
08S
-0.66 815 111 32 8
08S
-0.64 816 112 29 8
08S
-0.64 817 112 31 8
08S
-0.68 818 112 33 8
08S
-0.68 819 113 83 8
08S
-0.72 820 114 4
8 10S
-0.59 821 116 26 8
08S
-0.64 to the Enclosure to 1CAN031203 Page 24 of 42 Item Row Tube
%TW TSP Elevation (Inches) 822 116 40 8
08S
-0.73 823 117 29 8
08S
-0.61 824 117 59 8
08S
-0.74 825 117 67 8
08S
-0.74 826 119 67 8
08S
-0.74 827 119 69 8
08S
-0.71 828 120 58 8
08S
-0.74 829 120 62 8
08S
-0.72 830 120 66 8
08S
-0.72 831 120 78 8
08S
-0.7 832 121 30 8
08S 0.46 833 121 80 8
08S 0.45 834 121 102 8
10S 0.09 835 122 62 8
08S
-0.72 836 123 7
8 10S
-0.61 837 123 60 8
08S
-0.72 838 124 8
8 09S 0.53 839 124 32 8
08S
-0.71 840 124 48 8
08S
-0.73 841 124 76 8
08S
-0.7 842 125 1
8 13S 0.51 843 125 28 8
08S 0.46 844 126 48 8
09S
-0.71 845 127 88 8
09S 0.43 846 128 88 8
10S 0.04 847 130 10 8
09S 0.49 848 130 49 8
08S
-0.73 849 131 7
8 10S
-0.61 850 134 9
8 09S 0.47 851 138 7
8 10S
-0.63 852 140 13 8
14S
-0.72 853 142 62 8
11S 0.41 854 144 35 8
09S 0.39 855 145 36 8
11S 0.39 856 147 16 8
10S
-0.69 857 148 14 8
10S
-0.75 to the Enclosure to 1CAN031203 Page 25 of 42 Item Row Tube
%TW TSP Elevation (Inches) 858 148 23 8
10S 0.37 859 150 14 8
10S
-0.71 860 1
16 7
10S 0.52 861 1
23 7
10S 0.47 862 2
4 7
13S
-0.67 863 5
26 7
10S
-0.67 864 5
27 7
13S
-0.78 865 6
13 7
10S
-0.64 866 6
18 7
10S
-0.69 867 6
25 7
12S
-0.77 868 7
28 7
10S 0.41 869 7
38 7
10S 0.09 870 7
38 7
12S
-0.8 871 8
29 7
12S
-0.73 872 9
8 7
10S
-0.64 873 10 61 7
13S 0.35 874 11 15 7
10S
-0.71 875 11 65 7
10S
-0.13 876 21 82 7
10S
-0.73 877 23 44 7
08S
-0.71 878 24 30 7
08S
-0.65 879 25 47 7
08S 0.48 880 25 56 7
08S
-0.66 881 26 42 7
08S 0.45 882 26 54 7
08S
-0.64 883 26 54 7
08S 0.49 884 26 55 7
08S 0.47 885 26 67 7
08S
-0.67 886 26 71 7
08S
-0.68 887 26 94 7
10S 0.21 888 26 95 7
10S 0.11 889 27 36 7
08S
-0.63 890 27 45 7
07S 0.52 891 27 69 7
08S 0.42 892 27 73 7
08S 0.49 893 28 6
7 12S
-0.63 to the Enclosure to 1CAN031203 Page 26 of 42 Item Row Tube
%TW TSP Elevation (Inches) 894 28 43 7
08S 0.5 895 28 56 7
08S
-0.75 896 28 57 7
08S 0.45 897 29 33 7
08S
-0.63 898 29 33 7
08S 0.52 899 29 51 7
08S
-0.75 900 29 58 7
08S 0.52 901 29 60 7
08S 0.52 902 29 63 7
08S 0.45 903 29 64 7
08S 0.47 904 30 36 7
08S
-0.7 905 30 37 7
08S
-0.65 906 30 39 7
08S
-0.67 907 30 67 7
08S 0.47 908 30 68 7
08S
-0.71 909 30 72 7
08S 0.47 910 31 33 7
08S 0.5 911 31 67 7
08S 0.47 912 31 98 7
10S
-0.75 913 32 29 7
08S 0.51 914 32 65 7
08S 0.47 915 32 98 7
11S 0.39 916 33 45 7
08S
-0.75 917 34 6
7 09S
-0.58 918 34 79 7
08S 0.47 919 35 24 7
08S
-0.65 920 35 80 7
08S 0.47 921 35 90 7
08S 0.45 922 36 21 7
08S 0.56 923 36 22 7
08S 0.52 924 36 27 7
08S
-0.65 925 36 32 7
10S
-0.71 926 36 69 7
08S
-0.7 927 36 82 7
08S 0.45 928 36 107 7
11S 0.36 929 38 24 7
08S 0.5 to the Enclosure to 1CAN031203 Page 27 of 42 Item Row Tube
%TW TSP Elevation (Inches) 930 38 85 7
08S 0.47 931 38 109 7
10S
-0.75 932 39 25 7
08S 0.56 933 39 27 7
08S
-0.64 934 40 19 7
08S 0.52 935 41 20 7
08S
-0.6 936 41 94 7
08S 0.45 937 42 20 7
08S
-0.6 938 42 25 7
08S
-0.64 939 42 30 7
08S
-0.66 940 43 26 7
08S
-0.64 941 44 22 7
08S
-0.66 942 44 29 7
08S
-0.7 943 46 20 7
08S
-0.66 944 46 22 7
08S 0.44 945 46 96 7
08S 0.47 946 47 7
7 10S 0.54 947 47 23 7
08S
-0.66 948 47 82 7
08S 0.47 949 51 1
7 13S
-0.55 950 53 20 7
08S 0.51 951 54 26 7
08S
-0.68 952 54 95 7
06S
-0.73 953 55 8
7 09S 0.52 954 56 7
7 09S
-0.54 955 57 21 7
08S 0.6 956 59 21 7
08S 0.58 957 62 26 7
08S 0.56 958 63 19 7
08S
-0.57 959 65 23 7
08S
-0.71 960 65 27 7
08S 0.53 961 65 110 7
09S
-0.71 962 66 21 7
08S
-0.51 963 66 23 7
08S
-0.62 964 66 24 7
08S
-0.62 965 66 28 7
08S
-0.69 to the Enclosure to 1CAN031203 Page 28 of 42 Item Row Tube
%TW TSP Elevation (Inches) 966 67 102 7
07S
-0.68 967 68 111 7
09S
-0.77 968 69 110 7
10S 0.4 969 71 1
7 11S
-0.5 970 71 12 7
05S 0.53 971 71 23 7
08S 0.57 972 72 109 7
08S 0.43 973 72 109 7
10S
-0.81 974 74 29 7
08S 0.51 975 74 109 7
08S 0.45 976 74 116 7
09S
-0.72 977 76 27 7
08S 0.55 978 76 101 7
08S 0.47 979 76 108 7
08S 0.43 980 76 124 7
12S 0.3 981 77 22 7
08S 0.56 982 78 131 7
10S
-0.75 983 79 21 7
08S 0.57 984 79 27 7
08S 0.55 985 80 110 7
10S
-0.82 986 81 25 7
08S 0.53 987 81 114 7
08S 0.49 988 81 128 7
12S 0.32 989 82 22 7
08S 0.51 990 82 23 7
08S 0.49 991 82 34 7
08S 0.48 992 82 76 7
09S 0.57 993 82 113 7
08S 0.45 994 83 21 7
08S 0.51 995 83 29 7
08S 0.46 996 83 112 7
10S
-0.74 997 84 113 7
08S 0.46 998 85 97 7
07S 0.55 999 86 112 7
08S 0.46 1000 87 113 7
08S 0.46 1001 89 21 7
08S
-0.64 to the Enclosure to 1CAN031203 Page 29 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1002 92 4
7 09S 0.56 1003 92 25 7
08S
-0.66 1004 93 24 7
08S 0.57 1005 95 3
7 10S
-0.56 1006 95 23 7
08S
-0.64 1007 95 106 7
07S
-0.76 1008 96 19 7
08S
-0.61 1009 97 22 7
08S 0.53 1010 98 9
7 09S 0.55 1011 98 24 7
08S 0.55 1012 98 25 7
08S 0.53 1013 99 19 7
08S
-0.64 1014 99 107 7
08S
-0.74 1015 99 118 7
09S 0.42 1016 100 24 7
08S
-0.68 1017 104 23 7
08S
-0.64 1018 104 25 7
08S
-0.66 1019 105 8
7 09S
-0.61 1020 105 8
7 09S 0.5 1021 105 24 7
08S
-0.61 1022 106 23 7
08S 0.49 1023 107 3
7 10S 0.25 1024 107 30 7
08S
-0.65 1025 107 112 7
10S
-0.76 1026 107 114 7
10S
-0.78 1027 108 28 7
08S 0.42 1028 110 25 7
08S
-0.67 1029 110 29 7
08S
-0.76 1030 111 24 7
08S 0.49 1031 111 29 7
08S 0.51 1032 112 27 7
08S 0.51 1033 113 5
7 09S 0.54 1034 113 24 7
08S
-0.64 1035 113 31 7
08S 0.53 1036 114 108 7
10S
-0.72 1037 115 27 7
08S 0.49 to the Enclosure to 1CAN031203 Page 30 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1038 115 70 7
08S
-0.74 1039 116 33 7
08S
-0.72 1040 116 79 7
08S
-0.75 1041 116 86 7
08S 0.47 1042 116 109 7
10S 0
1043 117 6
7 09S 0.51 1044 117 28 7
08S
-0.66 1045 117 68 7
08S
-0.7 1046 119 25 7
08S
-0.63 1047 119 70 7
08S 0.46 1048 120 60 7
08S
-0.72 1049 120 76 7
08S
-0.72 1050 120 99 7
12S
-0.83 1051 121 31 7
08S
-0.66 1052 121 33 7
08S
-0.64 1053 121 59 7
08S
-0.72 1054 121 100 7
10S
-0.66 1055 121 101 7
10S 0.11 1056 122 34 7
08S 0.49 1057 122 72 7
07S
-0.7 1058 123 37 7
09S
-0.75 1059 123 74 7
08S 0.52 1060 124 38 7
08S 0.48 1061 124 39 7
09S
-0.7 1062 125 64 7
08S 0.45 1063 125 73 7
08S 0.5 1064 126 32 7
08S
-0.71 1065 126 47 7
08S
-0.72 1066 126 57 7
08S
-0.71 1067 127 64 7
08S 0.45 1068 127 91 7
10S
-0.69 1069 133 2
7 13S 0.49 1070 133 2
7 14S
-0.66 1071 133 83 7
13S
-0.86 1072 135 1
7 13S 0.53 1073 139 63 7
11S 0.41 to the Enclosure to 1CAN031203 Page 31 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1074 140 16 7
09S
-0.63 1075 140 16 7
09S 0.41 1076 140 58 7
11S 0.41 1077 140 60 7
11S 0.43 1078 141 10 7
10S
-0.69 1079 141 16 7
10S
-0.67 1080 142 60 7
11S 0.41 1081 143 41 7
09S 0.4 1082 144 8
7 10S
-0.67 1083 144 41 7
09S 0.36 1084 145 47 7
11S 0.45 1085 146 5
7 13S
-0.76 1086 146 36 7
11S 0.34 1087 147 10 7
10S
-0.7 1088 147 29 7
11S 0.3 1089 149 32 7
10S 0.37 1090 151 19 7
10S
-0.75 1091 1
6 6
13S 0.41 1092 1
17 6
10S 0.43 1093 3
11 6
10S 0.54 1094 5
28 6
10S
-0.71 1095 6
26 6
12S
-0.78 1096 6
33 6
10S 0.06 1097 7
6 6
13S 0.52 1098 8
51 6
14S 0.26 1099 9
10 6
10S 0.52 1100 10 13 6
10S
-0.58 1101 10 61 6
14S 0.3 1102 11 6
6 10S 0.54 1103 11 14 6
12S
-0.6 1104 12 15 6
10S 0.51 1105 12 22 6
09S
-0.66 1106 14 12 6
12S
-0.63 1107 16 4
6 10S 0.26 1108 21 45 6
08S 0.47 1109 21 84 6
10S 0.22 to the Enclosure to 1CAN031203 Page 32 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1110 22 85 6
10S 0.26 1111 24 53 6
08S 0.47 1112 25 40 6
08S 0.42 1113 26 43 6
08S
-0.67 1114 26 52 6
08S 0.49 1115 26 56 6
08S
-0.73 1116 26 65 6
08S 0.43 1117 27 27 6
08S
-0.65 1118 27 29 6
08S 0.5 1119 27 30 6
08S
-0.59 1120 27 34 6
08S
-0.63 1121 27 36 6
08S 0.5 1122 27 39 6
08S
-0.7 1123 27 40 6
08S
-0.65 1124 27 41 6
08S
-0.7 1125 27 42 6
09S
-0.74 1126 27 43 6
08S
-0.67 1127 27 46 6
08S 0.5 1128 27 51 6
08S 0.48 1129 27 71 6
08S 0.47 1130 28 28 6
08S 0.52 1131 28 38 6
08S
-0.67 1132 29 30 6
08S 0.52 1133 29 44 6
08S
-0.72 1134 29 49 6
08S
-0.73 1135 29 56 6
08S
-0.71 1136 29 56 6
08S 0.48 1137 29 57 6
08S 0.49 1138 29 61 6
08S
-0.68 1139 29 62 6
08S
-0.71 1140 29 63 6
08S
-0.71 1141 30 70 6
08S 0.47 1142 30 77 6
08S 0.43 1143 31 30 6
08S
-0.69 1144 31 79 6
08S 0.44 1145 31 101 6
10S 0.09 to the Enclosure to 1CAN031203 Page 33 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1146 32 25 6
08S 0.52 1147 32 32 6
08S 0.5 1148 32 49 6
08S
-0.86 1149 32 67 6
08S 0.47 1150 32 76 6
08S 0.38 1151 33 30 6
08S 0.47 1152 33 31 6
08S
-0.68 1153 34 69 6
08S 0.49 1154 34 82 6
08S 0.49 1155 35 77 6
08S 0.49 1156 35 87 6
08S 0.43 1157 37 84 6
08S 0.45 1158 39 25 6
08S
-0.64 1159 39 32 6
08S 0.5 1160 44 15 6
08S 0.56 1161 46 23 6
08S 0.49 1162 46 94 6
08S 0.45 1163 48 22 6
08S
-0.68 1164 48 98 6
08S 0.47 1165 49 8
6 09S 0.56 1166 50 94 6
08S 0.49 1167 55 99 6
08S 0.47 1168 56 19 6
08S 0.6 1169 57 109 6
08S 0.43 1170 58 20 6
08S 0.56 1171 58 24 6
08S 0.51 1172 59 126 6
12S
-0.81 1173 61 125 6
10S 0.28 1174 63 22 6
08S 0.51 1175 64 104 6
08S
-0.75 1176 68 32 6
08S
-0.63 1177 69 25 6
08S 0.58 1178 70 114 6
09S
-0.73 1179 71 21 6
08S 0.57 1180 73 10 6
09S 0.58 1181 74 110 6
08S 0.36 to the Enclosure to 1CAN031203 Page 34 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1182 76 20 6
08S
-0.62 1183 76 41 6
08S 0.53 1184 76 105 6
09S
-0.81 1185 76 107 6
06S 0.51 1186 76 107 6
08S 0.42 1187 77 19 6
08S 0.62 1188 77 23 6
08S
-0.68 1189 77 27 6
08S 0.49 1190 77 104 6
08S 0.43 1191 78 20 6
08S 0.59 1192 78 22 6
08S 0.53 1193 79 19 6
08S 0.55 1194 79 30 6
08S 0.52 1195 79 110 6
08S 0.38 1196 80 113 6
08S 0.41 1197 81 17 6
08S 0.53 1198 82 22 6
08S
-0.61 1199 82 24 6
08S 0.55 1200 82 111 6
08S 0.44 1201 82 115 6
08S 0.47 1202 83 23 6
08S 0.57 1203 83 25 6
08S 0.55 1204 84 15 6
08S 0.46 1205 84 17 6
08S 0.53 1206 85 6
6 09S
-0.52 1207 85 6
6 09S 0.54 1208 85 17 6
08S 0.59 1209 85 19 6
08S 0.55 1210 85 23 6
08S 0.55 1211 85 27 6
08S 0.51 1212 86 18 6
08S 0.55 1213 87 27 6
08S 0.51 1214 88 22 6
08S
-0.62 1215 88 115 6
08S 0.46 1216 90 4
6 09S 0.56 1217 90 5
6 09S 0.47 to the Enclosure to 1CAN031203 Page 35 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1218 90 22 6
08S 0.55 1219 90 24 6
08S 0.53 1220 92 109 6
08S 0.47 1221 93 1
6 13S 0.51 1222 94 2
6 13S 0.53 1223 95 111 6
08S 0.44 1224 96 24 6
08S
-0.68 1225 97 118 6
10S 0.28 1226 101 102 6
08S 0.4 1227 102 5
6 10S
-0.61 1228 103 103 6
08S 0.44 1229 105 28 6
08S
-0.63 1230 106 17 6
08S
-0.63 1231 106 32 6
08S
-0.65 1232 106 87 6
08S
-0.77 1233 107 22 6
08S
-0.69 1234 107 113 6
10S
-0.78 1235 109 27 6
08S 0.49 1236 109 90 6
08S
-0.7 1237 110 27 6
08S 0.51 1238 110 29 6
08S 0.48 1239 110 80 6
08S 0.47 1240 110 86 6
06S 0.38 1241 111 26 6
08S
-0.64 1242 111 27 6
09S
-0.65 1243 112 30 6
08S 0.51 1244 112 98 6
08S 0.49 1245 113 27 6
08S 0.53 1246 113 88 6
08S
-0.75 1247 113 110 6
10S
-0.79 1248 114 30 6
08S
-0.67 1249 114 109 6
10S
-0.79 1250 116 87 6
08S 0.39 1251 116 107 6
10S
-0.15 1252 117 22 6
08S 0.51 1253 117 37 6
08S 0.48 to the Enclosure to 1CAN031203 Page 36 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1254 118 76 6
09S
-0.74 1255 118 105 6
14S 0.19 1256 119 30 6
09S
-0.68 1257 119 34 6
08S
-0.66 1258 119 57 6
08S
-0.74 1259 119 101 6
10S
-0.7 1260 120 7
6 09S 0.53 1261 120 102 6
10S 0.02 1262 122 34 6
07S 0.49 1263 122 39 6
08S
-0.73 1264 122 63 6
08S
-0.73 1265 122 63 6
08S 0.43 1266 123 28 6
08S
-0.71 1267 123 65 6
08S 0.52 1268 123 71 6
08S 0.48 1269 123 99 6
10S 0.11 1270 124 31 6
08S
-0.7 1271 124 38 6
08S
-0.71 1272 125 9
6 09S 0.53 1273 125 27 6
10S
-0.77 1274 125 45 6
08S
-0.72 1275 125 54 6
08S
-0.67 1276 125 54 6
09S
-0.71 1277 126 21 6
10S
-0.73 1278 126 40 6
08S
-0.69 1279 126 54 6
08S
-0.63 1280 127 89 6
10S
-0.79 1281 128 2
6 14S 0.54 1282 128 48 6
08S
-0.71 1283 128 84 6
09S 0.39 1284 129 10 6
14S 0.47 1285 129 49 6
08S
-0.72 1286 131 1
6 14S
-0.61 1287 131 85 6
10S 0
1288 133 9
6 09S 0.52 1289 133 10 6
09S 0.47 to the Enclosure to 1CAN031203 Page 37 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1290 135 1
6 14S
-0.59 1291 136 7
6 13S
-0.72 1292 136 8
6 09S 0.49 1293 138 74 6
12S
-0.85 1294 140 66 6
10S 0.36 1295 141 16 6
09S 0.45 1296 143 55 6
10S 0.39 1297 145 32 6
09S 0.41 1298 145 44 6
11S 0.54 1299 146 34 6
10S 0.02 1300 146 43 6
10S
-0.75 1301 146 47 6
10S
-0.79 1302 147 30 6
11S 0.37 1303 148 25 6
10S 0.06 1304 1
19 5
13S
-0.75 1305 4
24 5
10S 0.04 1306 5
24 5
12S
-0.78 1307 6
35 5
15S 0.3 1308 7
46 5
10S 0.15 1309 18 21 5
09S
-0.65 1310 23 33 5
08S 0.5 1311 23 40 5
08S
-0.69 1312 24 31 5
08S
-0.61 1313 25 30 5
08S 0.46 1314 25 34 5
08S
-0.69 1315 25 50 5
08S
-0.65 1316 26 51 5
08S
-0.67 1317 27 31 5
08S
-0.65 1318 27 49 5
08S
-0.69 1319 27 55 5
08S
-0.69 1320 27 58 5
08S
-0.66 1321 27 97 5
10S 0.13 1322 28 31 5
08S
-0.65 1323 28 35 5
08S
-0.65 1324 28 43 5
07S
-0.69 1325 29 41 5
08S
-0.69 to the Enclosure to 1CAN031203 Page 38 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1326 31 32 5
08S 0.5 1327 32 31 5
08S 0.5 1328 32 53 5
08S
-0.75 1329 32 70 5
08S 0.49 1330 33 32 5
08S
-0.72 1331 34 27 5
08S
-0.63 1332 34 75 5
08S
-0.75 1333 35 82 5
08S
-0.73 1334 39 23 5
08S 0.54 1335 43 14 5
08S 0.54 1336 45 91 5
08S 0.49 1337 46 92 5
08S 0.45 1338 49 102 5
08S
-0.68 1339 51 99 5
09S
-0.75 1340 53 122 5
14S 0.22 1341 60 21 5
08S 0.56 1342 64 100 5
07S 0.54 1343 68 24 5
08S 0.53 1344 70 1
5 11S 0.55 1345 71 114 5
09S
-0.72 1346 72 114 5
08S 0.44 1347 73 2
5 11S 0.63 1348 74 6
5 09S 0.59 1349 74 110 5
07S 0.47 1350 75 6
5 09S
-0.48 1351 75 112 5
06S
-0.66 1352 76 5
5 09S 0.54 1353 76 15 5
09S 0.53 1354 76 17 5
08S 0.55 1355 76 19 5
08S 0.55 1356 76 23 5
08S 0.55 1357 76 23 5
09S
-0.63 1358 76 89 5
05S 0.59 1359 76 105 5
08S
-0.64 1360 76 122 5
12S
-0.76 1361 77 23 5
08S 0.55 to the Enclosure to 1CAN031203 Page 39 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1362 77 103 5
03S 0.48 1363 77 117 5
09S
-0.79 1364 79 6
5 09S 0.56 1365 80 109 5
08S 0.45 1366 81 3
5 13S 0.59 1367 83 6
5 10S 0.51 1368 83 19 5
08S 0.53 1369 83 114 5
08S 0.47 1370 84 21 5
08S 0.55 1371 84 107 5
08S
-0.72 1372 86 6
5 09S 0.55 1373 86 114 5
08S 0.44 1374 87 5
5 09S 0.56 1375 87 16 5
08S 0.53 1376 87 18 5
08S 0.57 1377 87 37 5
07S 0.57 1378 88 5
5 09S 0.57 1379 88 15 5
08S 0.57 1380 88 21 5
08S 0.59 1381 89 107 5
09S
-0.76 1382 90 20 5
08S 0.55 1383 90 26 5
08S 0.53 1384 94 1
5 13S 0.57 1385 99 107 5
08S 0.49 1386 100 1
5 13S
-0.61 1387 101 7
5 10S
-0.53 1388 103 20 5
08S 0.51 1389 105 7
5 09S 0.55 1390 106 24 5
08S
-0.6 1391 106 27 5
08S 0.53 1392 107 77 5
05S 0.55 1393 107 93 5
08S
-0.74 1394 108 109 5
10S
-0.78 1395 109 18 5
10S
-0.69 1396 109 98 5
08S 0.47 1397 111 15 5
09S 0.48 to the Enclosure to 1CAN031203 Page 40 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1398 111 31 5
08S
-0.72 1399 111 82 5
08S
-0.7 1400 112 23 5
08S 0.51 1401 113 94 5
08S
-0.79 1402 115 92 5
08S 0.36 1403 115 108 5
10S
-0.77 1404 116 6
5 09S 0.49 1405 116 26 5
08S 0.49 1406 117 7
5 09S 0.5 1407 118 83 5
08S 0.45 1408 119 27 5
08S
-0.63 1409 119 44 5
08S
-0.64 1410 119 104 5
10S 0.19 1411 120 24 5
08S
-0.65 1412 120 98 5
10S
-0.77 1413 121 26 5
08S
-0.66 1414 121 76 5
08S 0.48 1415 123 8
5 09S 0.52 1416 124 28 5
08S
-0.69 1417 124 30 5
08S
-0.67 1418 124 36 5
08S
-0.67 1419 125 8
5 09S 0.54 1420 125 54 5
06S 0.5 1421 125 56 5
08S 0.5 1422 125 58 5
08S
-0.67 1423 126 55 5
08S
-0.71 1424 130 39 5
08S
-0.71 1425 130 51 5
08S
-0.71 1426 132 46 5
08S 0.42 1427 133 37 5
08S
-0.69 1428 138 13 5
09S 0.48 1429 151 23 5
13S 0.28 1430 10 12 4
10S 0.43 1431 16 76 4
10S 0.13 1432 22 58 4
08S
-0.71 1433 25 31 4
08S 0.52 to the Enclosure to 1CAN031203 Page 41 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1434 25 63 4
08S
-0.74 1435 26 52 4
08S
-0.69 1436 27 28 4
08S 0.57 1437 27 54 4
08S
-0.73 1438 27 63 4
08S
-0.69 1439 28 16 4
10S 0.48 1440 28 54 4
08S 0.49 1441 30 56 4
08S
-0.69 1442 32 23 4
08S
-0.61 1443 32 36 4
08S
-0.65 1444 33 21 4
08S
-0.63 1445 35 23 4
08S 0.5 1446 61 21 4
08S 0.55 1447 73 126 4
14S 0.21 1448 77 6
4 09S 0.53 1449 77 118 4
10S
-0.79 1450 79 3
4 13S 0.53 1451 81 1
4 13S 0.57 1452 82 115 4
09S
-0.72 1453 83 2
4 13S 0.58 1454 85 112 4
08S 0.4 1455 87 4
4 10S 0.64 1456 88 111 4
08S 0.38 1457 89 3
4 10S 0.08 1458 90 3
4 10S 0.17 1459 93 107 4
08S 0.46 1460 95 109 4
08S 0.44 1461 98 105 4
08S 0.45 1462 99 97 4
08S
-0.76 1463 100 113 4
09S
-0.63 1464 101 102 4
08S
-0.71 1465 101 112 4
10S
-0.06 1466 109 96 4
08S 0.44 1467 115 6
4 09S 0.53 1468 118 106 4
10S 0.02 1469 123 29 4
08S
-0.71 to the Enclosure to 1CAN031203 Page 42 of 42 Item Row Tube
%TW TSP Elevation (Inches) 1470 125 53 4
08S
-0.68 1471 126 56 4
08S
-0.63 1472 130 34 4
08S
-0.68 1473 131 9
4 09S 0.5 1474 131 36 4
08S
-0.66 1475 132 38 4
08S
-0.66 1476 133 1
4 13S 0.55 1477 145 46 4
10S 0
1478 15 49 3
09S
-0.66 1479 19 41 3
08S
-0.75 1480 28 55 3
08S
-0.69 1481 32 10 3
10S 0.5 1482 33 21 3
09S
-0.63 1483 33 23 3
08S 0.54 1484 34 36 3
08S
-0.67 1485 61 22 3
08S 0.57 1486 106 112 3
10S
-0.74 1487 124 42 3
08S
-0.69 1488 129 40 3
08S
-0.71 1489 130 37 3
08S
-0.71 1490 132 30 3
08S
-0.67 1491 147 29 3
10S 0.06 1492 130 33 2
08S
-0.67 to the Enclosure to 1CAN031203 Page 1 of 41 SG B Tube Support Plate (TSP) Wear Item Row Tube
%TW TSP Elevation (Inches) 1 1
5 46 11S
-0.7 2
1 3
43 11S
-0.67 3
26 1
37 11S
-0.7 4
2 22 36 11S
-0.82 5
11 15 36 10S
-0.76 6
12 15 35 10S
-0.8 7
150 4
35 12S
-0.67 8
15 7
33 10S
-0.65 9
2 21 32 11S
-0.61 10 11 14 32 10S
-0.61 11 150 5
32 12S
-0.69 12 151 4
32 10S 0.41 13 151 15 31 12S
-0.75 14 21 7
30 10S
-0.67 15 1
4 29 11S
-0.64 16 23 8
29 10S
-0.76 17 4
10 28 12S
-0.19 18 124 1
28 12S
-0.85 19 151 2
28 12S
-0.74 20 1
16 27 11S
-0.72 21 19 1
27 11S
-0.74 22 122 105 27 11S 0.52 23 9
58 26 10S 0.52 24 17 82 26 10S 0.46 25 73 132 26 10S
-0.56 26 122 105 26 12S
-0.6 27 3
2 25 11S
-0.68 28 5
12 25 12S 0
29 150 27 25 12S 0.39 30 151 3
25 12S
-0.71 31 14 75 24 11S 0.43 32 151 15 24 12S 0.37 to the Enclosure to 1CAN031203 Page 2 of 41 Item Row Tube
%TW TSP Elevation (Inches) 33 1
8 23 11S
-0.62 34 2
4 23 11S
-0.67 35 2
7 23 11S
-0.6 36 7
39 23 11S 0.39 37 8
5 23 10S
-0.66 38 11 8
23 10S
-0.68 39 27 2
23 11S
-0.74 40 63 4
23 11S 0.39 41 116 113 23 10S 0.54 42 134 84 23 12S
-0.63 43 137 79 23 13S
-0.52 44 150 9
23 12S
-0.69 45 151 5
23 12S
-0.67 46 2
23 22 11S
-0.7 47 12 12 22 10S
-0.63 48 12 13 22 10S
-0.73 49 13 74 22 10S
-0.64 50 25 1
22 10S
-0.73 51 119 86 22 08S
-0.52 52 125 101 22 12S 0.52 53 132 89 22 10S
-0.65 54 151 4
22 11S 0.41 55 8
7 21 10S
-0.64 56 10 9
21 10S
-0.64 57 11 9
21 10S
-0.7 58 129 1
21 12S
-0.82 59 149 6
21 12S
-0.69 60 151 8
21 12S
-0.72 61 151 16 21 12S
-0.74 62 151 19 21 11S
-0.71 63 151 21 21 12S
-0.69 64 4
8 20 12S
-0.3 65 22 3
20 11S
-0.77 66 127 1
20 12S
-0.78 67 150 27 20 11S
-0.67 to the Enclosure to 1CAN031203 Page 3 of 41 Item Row Tube
%TW TSP Elevation (Inches) 68 151 1
20 12S
-0.73 69 151 5
20 10S 0.39 70 151 15 20 13S
-0.67 71 1
20 19 11S
-0.7 72 2
6 19 11S
-0.76 73 2
10 19 11S
-0.76 74 2
20 19 11S
-0.63 75 3
6 19 11S
-0.7 76 4
37 19 10S 0.51 77 6
44 19 11S
-0.74 78 12 7
19 10S
-0.64 79 12 11 19 10S
-0.68 80 15 79 19 11S
-0.6 81 16 81 19 10S 0.47 82 17 82 19 11S
-0.74 83 18 1
19 11S
-0.7 84 18 85 19 10S
-0.66 85 53 121 19 10S 0.56 86 77 1
19 11S
-0.83 87 123 1
19 12S
-0.84 88 127 98 19 11S 0.54 89 138 76 19 13S
-0.56 90 139 74 19 12S
-0.56 91 142 64 19 12S 0.52 92 150 6
19 12S
-0.69 93 150 7
19 12S
-0.69 94 150 26 19 11S
-0.71 95 150 26 19 12S 0.41 96 2
24 18 11S
-0.72 97 3
5 18 11S
-0.74 98 5
11 18 10S
-0.68 99 8
51 18 10S 0.54 100 9
4 18 10S
-0.64 101 15 80 18 10S
-0.66 102 18 78 18 10S 0.5 to the Enclosure to 1CAN031203 Page 4 of 41 Item Row Tube
%TW TSP Elevation (Inches) 103 31 33 18 08S 0.48 104 117 1
18 12S
-0.72 105 127 97 18 12S
-0.52 106 135 82 18 12S 0.54 107 136 81 18 11S 0.52 108 138 62 18 11S
-0.69 109 140 56 18 11S 0.5 110 140 69 18 12S
-0.58 111 141 9
18 15S 0.22 112 145 15 18 10S
-0.73 113 150 24 18 11S
-0.74 114 150 27 18 12S
-0.69 115 151 6
18 12S
-0.69 116 151 16 18 11S
-0.72 117 151 19 18 13S
-0.71 118 1
14 17 11S
-0.68 119 1
18 17 11S
-0.64 120 2
5 17 11S
-0.7 121 7
10 17 10S
-0.66 122 19 87 17 10S 0.52 123 24 45 17 08S 0.48 124 47 111 17 09S
-0.64 125 101 112 17 11S
-0.67 126 115 23 17 08S
-0.7 127 117 112 17 10S
-0.56 128 119 86 17 08S 0.54 129 124 103 17 10S
-0.54 130 126 1
17 12S
-0.86 131 129 94 17 12S 0.49 132 131 86 17 12S 0.5 133 136 81 17 13S 0.54 134 149 6
17 11S
-0.72 135 149 7
17 12S
-0.71 136 150 3
17 12S
-0.69 137 150 16 17 10S
-0.69 to the Enclosure to 1CAN031203 Page 5 of 41 Item Row Tube
%TW TSP Elevation (Inches) 138 150 20 17 12S
-0.73 139 150 25 17 12S 0.44 140 151 9
17 10S
-0.73 141 151 15 17 13S 0.35 142 151 17 17 13S
-0.67 143 151 19 17 12S
-0.69 144 151 19 17 12S 0.39 145 1
17 16 11S
-0.69 146 2
8 16 11S
-0.72 147 2
9 16 11S
-0.75 148 5
11 16 11S 0.44 149 5
11 16 12S 0
150 6
46 16 11S 0.5 151 7
15 16 10S
-0.71 152 9
57 16 11S 0.49 153 9
60 16 10S 0.51 154 13 15 16 10S
-0.68 155 13 16 16 10S
-0.7 156 16 79 16 11S
-0.7 157 18 83 16 10S 0.45 158 19 80 16 10S 0.48 159 23 45 16 08S 0.43 160 24 1
16 11S
-0.77 161 31 37 16 08S 0.48 162 44 116 16 13S
-0.72 163 79 1
16 12S
-0.76 164 102 113 16 11S
-0.67 165 113 1
16 12S
-0.72 166 127 97 16 11S
-0.59 167 132 88 16 11S
-0.65 168 133 88 16 12S
-0.54 169 134 79 16 13S 0.48 170 134 84 16 11S
-0.67 171 136 80 16 13S
-0.54 172 140 59 16 13S
-0.68 to the Enclosure to 1CAN031203 Page 6 of 41 Item Row Tube
%TW TSP Elevation (Inches) 173 141 58 16 13S
-0.67 174 150 23 16 11S
-0.65 175 150 29 16 11S
-0.69 176 151 16 16 13S
-0.68 177 151 18 16 13S
-0.7 178 2
2 15 10S 0.48 179 3
5 15 10S
-0.68 180 3
8 15 10S
-0.66 181 5
12 15 10S
-0.69 182 6
8 15 10S
-0.7 183 8
8 15 11S 0.46 184 9
12 15 10S
-0.71 185 12 67 15 11S
-0.57 186 14 75 15 11S
-0.66 187 15 78 15 11S
-0.63 188 15 79 15 10S 0.47 189 17 84 15 11S
-0.72 190 18 84 15 11S
-0.72 191 21 2
15 11S
-0.77 192 53 119 15 10S 0.49 193 68 7
15 14S 0.25 194 72 131 15 10S
-0.6 195 122 105 15 10S
-0.58 196 125 1
15 12S
-0.88 197 126 1
15 12S 0.39 198 134 85 15 12S
-0.59 199 136 80 15 12S
-0.56 200 136 81 15 12S
-0.56 201 140 10 15 15S 0.24 202 140 56 15 12S 0.41 203 144 48 15 13S
-0.59 204 146 25 15 11S
-0.72 205 149 9
15 12S
-0.73 206 150 7
15 10S 0.41 207 150 12 15 10S
-0.69 to the Enclosure to 1CAN031203 Page 7 of 41 Item Row Tube
%TW TSP Elevation (Inches) 208 150 25 15 13S 0.44 209 150 26 15 13S 0.41 210 151 12 15 12S
-0.69 211 2
2 14 11S 0.52 212 2
28 14 11S
-0.67 213 4
10 14 11S 0.41 214 4
12 14 12S
-0.2 215 5
41 14 11S
-0.63 216 6
47 14 10S 0.51 217 7
48 14 11S
-0.68 218 7
49 14 11S 0.52 219 8
6 14 10S
-0.68 220 8
39 14 10S 0.39 221 9
5 14 10S
-0.65 222 13 6
14 10S
-0.7 223 15 80 14 11S
-0.72 224 24 2
14 11S
-0.77 225 25 3
14 11S
-0.79 226 48 121 14 13S
-0.59 227 54 124 14 12S 0.46 228 55 125 14 10S 0.63 229 73 131 14 09S
-0.54 230 93 128 14 12S
-0.6 231 130 86 14 12S 0.43 232 132 1
14 12S
-0.86 233 132 88 14 13S
-0.56 234 132 89 14 11S 0.52 235 133 87 14 12S
-0.62 236 134 1
14 12S
-0.78 237 136 8
14 12S 0.35 238 136 77 14 12S 0.5 239 138 69 14 11S
-0.61 240 139 72 14 12S 0.52 241 140 55 14 13S 0.4 242 141 59 14 13S
-0.63 to the Enclosure to 1CAN031203 Page 8 of 41 Item Row Tube
%TW TSP Elevation (Inches) 243 147 8
14 10S
-0.75 244 147 9
14 10S
-0.72 245 147 29 14 10S 0.15 246 150 22 14 12S
-0.73 247 150 30 14 12S
-0.71 248 151 16 14 13S 0.39 249 151 17 14 12S
-0.73 250 1
15 13 11S
-0.69 251 2
27 13 11S
-0.66 252 3
9 13 10S 0.44 253 3
9 13 12S 0.28 254 3
10 13 11S
-0.7 255 6
7 13 10S
-0.68 256 9
59 13 11S
-0.64 257 10 59 13 13S
-0.76 258 12 9
13 10S
-0.68 259 12 10 13 10S
-0.7 260 13 72 13 11S
-0.55 261 14 62 13 10S 0.46 262 15 65 13 10S 0.45 263 20 7
13 10S
-0.7 264 20 51 13 08S 0.45 265 20 83 13 11S 0.38 266 22 66 13 08S 0.48 267 24 44 13 08S 0.45 268 25 52 13 08S 0.43 269 27 13 13 14S
-0.85 270 31 1
13 11S
-0.77 271 31 34 13 08S 0.55 272 31 36 13 08S 0.44 273 32 30 13 08S 0.46 274 48 1
13 11S 0.47 275 52 121 13 13S
-0.61 276 53 118 13 10S 0.56 277 60 125 13 14S 0.54 to the Enclosure to 1CAN031203 Page 9 of 41 Item Row Tube
%TW TSP Elevation (Inches) 278 80 1
13 11S
-0.82 279 87 3
13 10S 0.17 280 100 115 13 11S
-0.65 281 102 7
13 10S 0.02 282 116 113 13 11S 0.5 283 122 1
13 12S
-0.8 284 127 93 13 11S
-0.61 285 128 1
13 12S
-0.8 286 130 93 13 11S 0.56 287 131 87 13 12S 0.52 288 131 90 13 12S
-0.54 289 135 83 13 12S
-0.58 290 135 84 13 12S
-0.63 291 136 81 13 10S
-0.65 292 137 66 13 11S
-0.69 293 137 78 13 12S
-0.6 294 140 56 13 11S
-0.74 295 141 60 13 14S 0.41 296 141 61 13 14S 0.44 297 144 40 13 09S
-0.59 298 146 12 13 10S
-0.74 299 146 22 13 11S
-0.74 300 146 24 13 11S
-0.69 301 146 32 13 10S 0.11 302 147 26 13 13S
-0.78 303 149 5
13 12S
-0.67 304 150 1
13 12S
-0.67 305 150 21 13 12S 0.41 306 150 25 13 13S
-0.54 307 150 29 13 13S
-0.65 308 151 6
13 10S 0.48 309 151 8
13 11S
-0.72 310 151 15 13 11S
-0.71 311 151 17 13 13S 0.37 312 151 20 13 13S
-0.67 to the Enclosure to 1CAN031203 Page 10 of 41 Item Row Tube
%TW TSP Elevation (Inches) 313 1
10 12 11S
-0.7 314 1
24 12 11S
-0.65 315 2
17 12 11S
-0.7 316 2
18 12 11S
-0.65 317 3
10 12 10S
-0.68 318 5
37 12 11S 0.46 319 5
39 12 11S 0.52 320 6
4 12 10S
-0.68 321 6
39 12 11S 0.45 322 7
11 12 10S
-0.7 323 8
1 12 10S 0.5 324 8
38 12 10S 0.38 325 8
47 12 11S 0.48 326 9
9 12 10S
-0.7 327 9
28 12 10S 0.31 328 9
60 12 12S
-0.74 329 10 33 12 10S 0.39 330 10 65 12 10S 0.51 331 11 7
12 10S
-0.68 332 11 13 12 10S
-0.68 333 12 18 12 10S 0.46 334 16 81 12 11S
-0.74 335 17 1
12 11S
-0.76 336 18 83 12 11S
-0.72 337 21 8
12 10S
-0.73 338 22 41 12 08S 0.45 339 22 93 12 11S
-0.75 340 23 2
12 11S
-0.76 341 24 43 12 08S 0.5 342 32 1
12 11S
-0.77 343 34 1
12 11S
-0.75 344 44 117 12 11S
-0.7 345 48 114 12 09S
-0.67 346 49 122 12 13S
-0.71 347 53 120 12 14S
-0.58 to the Enclosure to 1CAN031203 Page 11 of 41 Item Row Tube
%TW TSP Elevation (Inches) 348 63 129 12 12S 0.52 349 64 129 12 10S 0.59 350 71 132 12 10S
-0.58 351 84 4
12 10S 0.09 352 92 112 12 08S 0.55 353 98 122 12 14S 0.53 354 99 116 12 11S
-0.67 355 101 120 12 12S 0.54 356 104 6
12 04S
-0.67 357 107 113 12 11S 0.52 358 117 112 12 11S 0.54 359 121 105 12 12S
-0.63 360 125 1
12 12S 0.37 361 125 70 12 08S 0.5 362 127 98 12 12S 0.51 363 130 1
12 12S
-0.85 364 134 84 12 10S
-0.52 365 134 85 12 10S
-0.62 366 135 82 12 12S
-0.56 367 135 83 12 11S 0.64 368 135 83 12 13S
-0.56 369 135 83 12 13S 0.52 370 136 8
12 12S
-0.78 371 137 69 12 11S
-0.68 372 139 59 12 11S
-0.75 373 139 60 12 11S
-0.68 374 141 56 12 14S
-0.74 375 141 63 12 14S 0.5 376 142 65 12 10S
-0.67 377 144 11 12 13S
-0.78 378 146 7
12 12S
-0.76 379 149 31 12 11S
-0.74 380 150 22 12 11S
-0.71 381 150 26 12 13S
-0.69 382 150 30 12 12S 0.43 to the Enclosure to 1CAN031203 Page 12 of 41 Item Row Tube
%TW TSP Elevation (Inches) 383 151 3
12 10S 0.41 384 151 4
12 12S
-0.72 385 151 9
12 13S 0.35 386 151 10 12 08S
-0.67 387 151 10 12 13S
-0.69 388 151 12 12 13S
-0.69 389 151 15 12 11S 0.43 390 151 20 12 12S
-0.71 391 2
26 11 11S
-0.63 392 3
1 11 11S 0.48 393 3
1 11 11S
-0.68 394 3
11 11 08S 0.5 395 4
5 11 11S
-0.68 396 4
10 11 10S
-0.66 397 5
8 11 12S
-0.79 398 5
12 11 11S 0.39 399 5
27 11 10S 0.13 400 5
39 11 11S
-0.67 401 6
21 11 10S
-0.75 402 6
30 11 10S 0.07 403 6
44 11 11S 0.52 404 6
45 11 12S 0.34 405 7
40 11 11S 0.45 406 7
48 11 10S 0.53 407 8
1 11 11S
-0.68 408 8
54 11 12S
-0.72 409 9
1 11 10S 0.5 410 9
56 11 12S 0.35 411 10 2
11 10S 0.5 412 10 4
11 10S 0.48 413 10 60 11 13S 0.28 414 10 61 11 11S
-0.61 415 10 62 11 11S 0.51 416 12 1
11 10S 0.48 417 12 67 11 11S 0.62 to the Enclosure to 1CAN031203 Page 13 of 41 Item Row Tube
%TW TSP Elevation (Inches) 418 15 67 11 10S 0.45 419 15 69 11 10S 0.45 420 15 72 11 14S 0.31 421 16 75 11 10S 0.49 422 17 84 11 10S
-0.72 423 21 82 11 10S 0.41 424 24 5
11 10S
-0.74 425 25 36 11 08S 0.44 426 25 84 11 13S
-0.75 427 26 39 11 06S 0.45 428 29 67 11 07S
-0.57 429 31 2
11 11S
-0.74 430 37 31 11 08S 0.47 431 38 111 11 10S 0.42 432 45 113 11 09S
-0.5 433 46 119 11 11S
-0.67 434 47 114 11 10S 0.56 435 48 115 11 14S 0.42 436 49 1
11 11S
-0.72 437 52 4
11 10S
-0.7 438 53 116 11 13S
-0.73 439 53 118 11 13S
-0.67 440 53 120 11 10S 0.58 441 54 118 11 13S
-0.73 442 54 124 11 12S
-0.61 443 63 125 11 09S 0.52 444 63 128 11 12S 0.5 445 64 125 11 10S 0.53 446 67 130 11 12S 0.52 447 68 131 11 10S
-0.56 448 72 131 11 11S 0.57 449 75 5
11 10S
-0.04 450 77 132 11 09S
-0.59 451 81 113 11 07S
-0.55 452 85 125 11 14S 0.5 to the Enclosure to 1CAN031203 Page 14 of 41 Item Row Tube
%TW TSP Elevation (Inches) 453 98 115 11 09S
-0.62 454 100 3
11 10S 0.26 455 100 114 11 09S 0.5 456 104 6
11 10S 0.04 457 104 114 11 11S
-0.69 458 107 117 11 11S 0.52 459 114 110 11 11S
-0.65 460 118 111 11 10S
-0.6 461 118 111 11 11S 0.5 462 118 111 11 13S 0.56 463 122 104 11 11S 0.54 464 124 98 11 11S
-0.61 465 125 100 11 11S
-0.65 466 126 76 11 08S 0.54 467 128 91 11 12S
-0.56 468 130 38 11 08S 0.43 469 131 8
11 10S
-0.79 470 133 80 11 14S 0.46 471 133 86 11 12S
-0.6 472 135 82 11 11S
-0.56 473 135 84 11 13S
-0.54 474 136 81 11 13S
-0.54 475 137 79 11 11S
-0.61 476 139 68 11 11S
-0.63 477 140 65 11 14S 0.46 478 141 55 11 11S
-0.67 479 141 63 11 13S
-0.59 480 141 68 11 12S
-0.58 481 142 54 11 10S 0.3 482 142 64 11 12S
-0.58 483 143 7
11 13S
-0.78 484 144 52 11 13S
-0.59 485 145 16 11 11S
-0.76 486 145 47 11 13S
-0.65 487 146 12 11 12S 0.37 to the Enclosure to 1CAN031203 Page 15 of 41 Item Row Tube
%TW TSP Elevation (Inches) 488 146 13 11 12S 0.32 489 146 14 11 10S
-0.67 490 146 30 11 13S
-0.8 491 146 36 11 10S 0.13 492 149 8
11 12S
-0.7 493 150 5
11 13S
-0.69 494 150 8
11 12S
-0.69 495 150 19 11 11S
-0.72 496 150 23 11 12S 0.46 497 150 25 11 11S
-0.74 498 150 27 11 13S
-0.63 499 150 28 11 11S
-0.75 500 151 2
11 11S
-0.7 501 151 2
11 12S 0.41 502 151 12 11 12S 0.43 503 151 16 11 12S 0.44 504 151 17 11 11S
-0.71 505 151 24 11 12S 0.48 506 1
19 10 11S
-0.74 507 3
4 10 10S 0.49 508 3
5 10 10S 0.5 509 3
6 10 11S 0.47 510 3
9 10 14S
-0.72 511 3
12 10 12S
-0.73 512 3
12 10 12S 0.32 513 5
13 10 14S
-0.83 514 5
23 10 10S
-0.74 515 7
41 10 11S 0.46 516 7
49 10 12S 0.44 517 8
10 10 10S
-0.65 518 8
51 10 11S
-0.65 519 9
56 10 12S
-0.71 520 10 29 10 08S
-0.72 521 10 44 10 14S 0.28 522 10 54 10 11S 0.45 to the Enclosure to 1CAN031203 Page 16 of 41 Item Row Tube
%TW TSP Elevation (Inches) 523 11 10 10 10S
-0.66 524 11 58 10 10S 0.5 525 11 64 10 11S 0.48 526 12 69 10 10S 0.51 527 13 18 10 10S
-0.76 528 13 60 10 10S 0.47 529 14 24 10 14S 0.26 530 14 76 10 11S
-0.61 531 14 77 10 10S 0.51 532 15 73 10 09S
-0.66 533 16 8
10 10S
-0.72 534 16 79 10 11S 0.47 535 17 13 10 10S
-0.7 536 19 42 10 08S 0.44 537 20 82 10 10S 0.46 538 21 58 10 08S 0.47 539 21 83 10 10S 0.46 540 22 36 10 08S
-0.74 541 22 93 10 10S
-0.73 542 24 41 10 08S 0.48 543 24 51 10 08S 0.5 544 25 2
10 10S
-0.74 545 26 92 10 10S 0.45 546 28 2
10 11S
-0.79 547 28 62 10 08S 0.47 548 29 2
10 11S
-0.76 549 30 33 10 08S 0.46 550 31 78 10 08S 0.47 551 45 114 10 09S
-0.67 552 48 20 10 09S
-0.68 553 48 38 10 08S 0.5 554 48 113 10 09S
-0.59 555 49 115 10 13S
-0.72 556 51 120 10 10S 0.63 557 53 117 10 10S 0.47 to the Enclosure to 1CAN031203 Page 17 of 41 Item Row Tube
%TW TSP Elevation (Inches) 558 53 122 10 10S 0.61 559 54 123 10 11S 0.61 560 54 124 10 13S
-0.65 561 55 124 10 09S 0.5 562 58 126 10 11S 0.56 563 60 127 10 10S 0.56 564 63 128 10 13S
-0.67 565 65 128 10 12S 0.52 566 72 131 10 12S 0.56 567 73 127 10 09S
-0.59 568 73 132 10 08S
-0.54 569 73 132 10 08S 0.5 570 74 131 10 12S 0.54 571 81 113 10 08S 0.51 572 82 4
10 10S 0.04 573 82 115 10 08S 0.54 574 83 5
10 10S 0.09 575 86 25 10 08S 0.45 576 91 5
10 12S
-0.78 577 91 111 10 08S 0.57 578 93 4
10 11S
-0.8 579 96 109 10 08S 0.55 580 97 116 10 09S 0.55 581 98 117 10 11S
-0.63 582 99 115 10 09S
-0.64 583 106 106 10 08S 0.56 584 110 22 10 08S 0.44 585 113 24 10 08S 0.44 586 122 99 10 11S
-0.67 587 124 102 10 11S 0.54 588 124 102 10 12S
-0.58 589 125 31 10 08S 0.39 590 125 70 10 08S
-0.63 591 127 98 10 12S
-0.67 592 130 49 10 08S 0.49 to the Enclosure to 1CAN031203 Page 18 of 41 Item Row Tube
%TW TSP Elevation (Inches) 593 132 7
10 14S
-0.83 594 132 86 10 13S 0.5 595 132 88 10 12S
-0.54 596 133 87 10 11S 0.52 597 134 79 10 11S
-0.65 598 135 78 10 14S 0.5 599 135 83 10 11S
-0.69 600 136 7
10 13S 0.28 601 136 76 10 14S 0.43 602 137 10 10 14S 0.24 603 138 75 10 12S
-0.61 604 139 64 10 12S 0.5 605 140 55 10 11S
-0.72 606 141 10 10 15S 0.26 607 141 56 10 10S 0.26 608 142 23 10 14S
-0.73 609 142 53 10 11S
-0.68 610 143 21 10 14S
-0.86 611 144 9
10 15S
-0.69 612 146 10 10 10S
-0.7 613 146 13 10 12S
-0.76 614 146 44 10 10S 0.09 615 148 23 10 12S 0.39 616 148 26 10 12S 0.37 617 150 9
10 12S 0.28 618 150 10 10 13S
-0.72 619 150 20 10 12S 0.37 620 150 24 10 12S
-0.73 621 151 1
10 10S 0.41 622 151 3
10 13S
-0.78 623 151 8
10 10S 0.46 624 151 18 10 12S
-0.76 625 3
9 9
14S 0.35 626 3
11 9
12S
-0.78 627 3
34 9
10S 0.49 to the Enclosure to 1CAN031203 Page 19 of 41 Item Row Tube
%TW TSP Elevation (Inches) 628 4
36 9
11S
-0.63 629 5
3 9
10S 0.46 630 5
39 9
13S
-0.76 631 6
44 9
10S 0.5 632 6
46 9
11S
-0.63 633 7
47 9
10S 0.52 634 7
50 9
10S 0.53 635 8
39 9
13S 0.33 636 8
50 9
10S 0.49 637 9
53 9
13S
-0.75 638 10 11 9
11S
-0.75 639 10 57 9
10S 0.52 640 11 2
9 11S 0.49 641 11 34 9
10S 0.39 642 11 60 9
10S 0.54 643 11 62 9
10S 0.5 644 11 66 9
11S
-0.63 645 12 2
9 10S 0.44 646 12 57 9
10S 0.48 647 13 17 9
11S
-0.82 648 13 74 9
10S 0.49 649 14 70 9
11S 0.48 650 15 5
9 10S 0.41 651 15 25 9
14S 0.24 652 15 72 9
14S
-0.72 653 16 1
9 11S
-0.76 654 16 80 9
13S
-0.81 655 20 51 9
08S
-0.6 656 22 36 9
08S 0.46 657 22 41 9
06S
-0.59 658 22 57 9
08S 0.45 659 23 5
9 10S
-0.75 660 23 59 9
08S 0.45 661 24 49 9
08S 0.46 662 25 33 9
08S 0.47 to the Enclosure to 1CAN031203 Page 20 of 41 Item Row Tube
%TW TSP Elevation (Inches) 663 25 34 9
08S 0.46 664 25 53 9
07S 0.48 665 25 96 9
10S 0.45 666 26 45 9
07S 0.49 667 28 42 9
08S 0.52 668 28 49 9
08S 0.49 669 29 33 9
08S 0.44 670 31 33 9
10S
-0.76 671 33 28 9
08S 0.43 672 33 89 9
08S 0.51 673 36 108 9
09S
-0.68 674 38 1
9 10S 0.47 675 41 114 9
14S
-0.7 676 44 113 9
09S
-0.69 677 47 2
9 10S 0.42 678 48 115 9
10S 0.53 679 48 121 9
11S 0.67 680 49 8
9 10S 0.13 681 50 113 9
09S
-0.65 682 54 119 9
10S 0.49 683 54 123 9
10S 0.63 684 54 125 9
12S 0.42 685 55 120 9
09S 0.54 686 57 127 9
10S 0.63 687 58 108 9
09S 0.51 688 59 127 9
10S 0.59 689 65 110 9
10S 0.47 690 68 113 9
08S 0.6 691 69 8
9 14S
-0.87 692 70 131 9
09S
-0.5 693 73 126 9
09S
-0.61 694 74 117 9
09S
-0.63 695 74 127 9
12S 0.55 696 75 125 9
14S 0.47 697 75 127 9
13S
-0.52 to the Enclosure to 1CAN031203 Page 21 of 41 Item Row Tube
%TW TSP Elevation (Inches) 698 76 29 9
03S 0.6 699 77 126 9
09S
-0.62 700 77 127 9
09S
-0.56 701 80 4
9 10S 0
702 81 5
9 10S 0.15 703 81 112 9
08S 0.59 704 83 23 9
08S 0.46 705 84 18 9
08S
-0.78 706 85 125 9
09S 0.49 707 85 129 9
07S
-0.58 708 86 4
9 10S 0.13 709 88 4
9 10S 0.2 710 88 112 9
08S 0.54 711 94 109 9
08S 0.52 712 94 111 9
08S 0.58 713 95 107 9
08S 0.54 714 95 112 9
09S 0.48 715 96 118 9
09S 0.54 716 96 124 9
14S 0.5 717 97 23 9
08S 0.46 718 98 109 9
08S
-0.56 719 98 122 9
11S
-0.67 720 98 125 9
12S
-0.6 721 99 6
9 10S 0.04 722 99 107 9
08S
-0.56 723 99 107 9
08S 0.56 724 99 124 9
13S 0.5 725 100 5
9 10S 0.11 726 100 115 9
09S 0.56 727 101 20 9
08S 0.45 728 101 23 9
08S 0.48 729 103 113 9
09S
-0.56 730 104 104 9
08S 0.54 731 104 107 9
09S 0.52 732 104 113 9
11S
-0.67 to the Enclosure to 1CAN031203 Page 22 of 41 Item Row Tube
%TW TSP Elevation (Inches) 733 105 114 9
12S 0.47 734 110 22 9
08S
-0.72 735 110 106 9
09S 0.49 736 111 98 9
08S 0.56 737 115 88 9
06S
-0.62 738 116 87 9
08S 0.47 739 118 93 9
08S 0.54 740 118 106 9
11S
-0.65 741 119 79 9
08S 0.54 742 119 87 9
08S 0.51 743 120 30 9
08S 0.46 744 121 106 9
11S 0.54 745 122 79 9
08S 0.56 746 123 31 9
08S 0.47 747 123 31 9
08S
-0.71 748 125 86 9
08S
-0.56 749 125 86 9
08S 0.5 750 125 97 9
11S
-0.62 751 127 69 9
08S 0.49 752 128 60 9
08S 0.51 753 128 64 9
08S 0.53 754 128 70 9
08S 0.55 755 128 88 9
10S 0.26 756 129 28 9
08S 0.45 757 130 92 9
10S
-0.69 758 130 92 9
12S
-0.54 759 132 82 9
09S 0.52 760 132 82 9
11S
-0.63 761 133 84 9
10S
-0.65 762 133 87 9
13S 0.52 763 134 84 9
08S 0.52 764 137 3
9 12S
-0.73 765 137 8
9 12S 0.35 766 137 65 9
09S
-0.61 767 137 77 9
13S 0.52 to the Enclosure to 1CAN031203 Page 23 of 41 Item Row Tube
%TW TSP Elevation (Inches) 768 138 67 9
13S 0.48 769 138 76 9
12S
-0.6 770 142 64 9
11S 0.7 771 142 65 9
11S
-0.69 772 142 65 9
13S
-0.62 773 143 13 9
13S 0.3 774 145 2
9 08S
-0.7 775 146 1
9 11S
-0.8 776 147 28 9
10S 0.06 777 147 41 9
13S 0.5 778 147 42 9
11S
-0.69 779 147 42 9
14S 0.28 780 148 25 9
10S 0.04 781 148 26 9
10S 0.11 782 149 17 9
13S 0.48 783 151 18 9
11S
-0.72 784 1
1 8
11S
-0.7 785 2
16 8
11S
-0.69 786 3
35 8
10S 0.57 787 4
1 8
10S 0.52 788 5
12 8
14S
-0.81 789 5
26 8
10S 0.09 790 5
42 8
10S 0.55 791 6
4 8
10S 0.44 792 7
47 8
11S 0.52 793 7
49 8
10S 0.52 794 8
4 8
10S 0.48 795 9
56 8
10S 0.54 796 9
59 8
10S 0.51 797 10 7
8 10S
-0.66 798 10 15 8
14S
-0.81 799 10 56 8
10S 0.49 800 10 59 8
10S 0.52 801 10 61 8
12S 0.3 802 11 2
8 11S
-0.64 to the Enclosure to 1CAN031203 Page 24 of 41 Item Row Tube
%TW TSP Elevation (Inches) 803 11 31 8
14S
-0.82 804 12 6
8 10S
-0.68 805 12 64 8
10S 0.52 806 12 66 8
11S
-0.72 807 13 13 8
10S 0.46 808 13 56 8
14S 0.3 809 13 68 8
10S 0.49 810 13 69 8
13S 0.35 811 14 38 8
14S 0.22 812 15 66 8
10S 0.44 813 18 8
8 10S 0.41 814 18 54 8
08S
-0.63 815 20 11 8
10S 0.38 816 20 29 8
08S 0.44 817 20 51 8
09S
-0.75 818 20 81 8
10S 0.45 819 21 33 8
08S 0.5 820 21 57 8
08S 0.48 821 22 12 8
10S 0.38 822 22 38 8
07S 0.5 823 22 58 8
08S 0.48 824 23 51 8
08S 0.47 825 24 45 8
08S
-0.57 826 25 31 8
08S 0.38 827 25 44 8
07S 0.48 828 25 53 8
08S 0.48 829 26 13 8
10S 0.38 830 26 28 8
08S 0.46 831 27 30 8
08S 0.44 832 27 48 8
07S 0.47 833 27 48 8
08S 0.47 834 27 56 8
08S 0.48 835 27 67 8
08S 0.49 836 29 31 8
08S 0.46 837 30 36 8
08S 0.44 to the Enclosure to 1CAN031203 Page 25 of 41 Item Row Tube
%TW TSP Elevation (Inches) 838 30 77 8
08S 0.49 839 31 2
8 10S
-0.76 840 31 79 8
08S 0.45 841 32 100 8
10S 0.47 842 33 52 8
08S 0.46 843 33 79 8
08S 0.45 844 33 87 8
08S 0.53 845 36 90 8
08S
-0.63 846 37 24 8
08S 0.48 847 37 31 8
09S 0.43 848 37 93 8
08S
-0.58 849 37 110 8
10S 0.49 850 38 69 8
04S 0.58 851 41 113 8
10S 0.46 852 41 114 8
11S
-0.67 853 45 116 8
10S 0.6 854 46 2
8 10S 0.5 855 46 114 8
14S
-0.7 856 46 115 8
10S 0.51 857 46 116 8
10S 0.54 858 47 117 8
13S
-0.74 859 48 116 8
13S
-0.68 860 49 115 8
10S 0.51 861 50 114 8
10S 0.48 862 52 4
8 13S 0.33 863 52 121 8
10S 0.59 864 56 112 8
08S 0.51 865 56 126 8
10S 0.61 866 56 127 8
12S
-0.65 867 57 22 8
08S 0.46 868 59 124 8
09S 0.54 869 59 125 8
11S 0.53 870 60 19 8
08S 0.4 871 60 125 8
09S 0.52 872 61 127 8
10S 0.59 to the Enclosure to 1CAN031203 Page 26 of 41 Item Row Tube
%TW TSP Elevation (Inches) 873 61 129 8
12S
-0.67 874 62 124 8
10S 0.59 875 63 123 8
09S
-0.51 876 63 126 8
10S 0.57 877 66 109 8
08S 0.52 878 67 130 8
13S
-0.62 879 68 126 8
09S 0.54 880 68 131 8
10S 0.52 881 69 128 8
13S
-0.67 882 70 6
8 13S 0.33 883 71 5
8 10S 0.11 884 73 108 8
08S 0.47 885 74 124 8
13S
-0.6 886 75 126 8
09S
-0.56 887 75 126 8
09S 0.52 888 75 131 8
12S 0.5 889 76 124 8
14S 0.52 890 77 118 8
09S 0.51 891 78 125 8
09S 0.54 892 80 114 8
08S 0.51 893 80 115 8
08S 0.57 894 80 126 8
09S
-0.57 895 81 126 8
09S 0.56 896 82 116 8
08S 0.55 897 82 126 8
09S 0.51 898 83 25 8
08S 0.43 899 84 126 8
09S 0.56 900 87 25 8
08S 0.48 901 88 110 8
08S 0.57 902 88 116 8
09S 0.52 903 88 122 8
09S 0.49 904 89 4
8 10S 0.15 905 90 116 8
09S 0.48 906 90 124 8
14S 0.5 907 93 108 8
08S 0.55 to the Enclosure to 1CAN031203 Page 27 of 41 Item Row Tube
%TW TSP Elevation (Inches) 908 93 125 8
09S 0.52 909 94 112 8
08S 0.57 910 95 112 8
08S 0.55 911 95 118 8
09S 0.53 912 96 111 8
08S 0.55 913 97 96 8
08S 0.56 914 97 109 8
08S 0.58 915 98 108 8
08S 0.54 916 98 109 8
08S 0.54 917 98 116 8
09S 0.54 918 98 118 8
11S
-0.65 919 98 120 8
11S
-0.6 920 99 115 8
09S 0.52 921 99 124 8
12S 0.54 922 100 21 8
08S 0.46 923 100 118 8
14S 0.5 924 101 106 8
08S 0.54 925 103 7
8 10S 0.17 926 105 106 8
08S 0.56 927 107 100 8
08S 0.58 928 107 104 8
08S 0.56 929 110 24 8
08S 0.48 930 110 109 8
14S 0.55 931 112 98 8
08S 0.56 932 115 93 8
08S 0.56 933 115 95 8
08S 0.54 934 116 27 8
08S 0.46 935 117 91 8
08S 0.54 936 118 31 8
08S 0.41 937 119 88 8
08S 0.56 938 120 22 8
08S 0.46 939 120 89 8
08S 0.52 940 120 100 8
11S
-0.63 941 121 83 8
08S 0.54 942 122 89 8
08S 0.52 to the Enclosure to 1CAN031203 Page 28 of 41 Item Row Tube
%TW TSP Elevation (Inches) 943 122 104 8
12S
-0.56 944 123 88 8
09S 0.5 945 124 30 8
08S 0.45 946 124 77 8
08S 0.52 947 124 102 8
12S 0.54 948 125 1
8 11S
-0.84 949 125 68 8
08S 0.54 950 125 73 8
08S 0.54 951 126 62 8
08S 0.52 952 126 76 8
08S
-0.63 953 126 98 8
12S
-0.61 954 126 99 8
11S 0.54 955 126 99 8
12S 0.59 956 127 65 8
08S 0.49 957 127 75 8
08S 0.56 958 128 58 8
08S 0.51 959 128 68 8
08S 0.55 960 128 87 8
11S
-0.67 961 128 91 8
12S 0.49 962 130 38 8
06S 0.5 963 130 41 8
08S 0.45 964 130 69 8
08S 0.49 965 130 88 8
10S 0.21 966 131 59 8
08S 0.52 967 132 88 8
12S 0.5 968 132 88 8
13S 0.54 969 132 89 8
12S
-0.58 970 133 86 8
11S 0.54 971 133 88 8
11S 0.54 972 134 1
8 12S 0.37 973 134 84 8
09S 0.54 974 134 84 8
11S 0.52 975 136 77 8
13S 0.5 976 136 79 8
13S
-0.56 977 136 81 8
11S
-0.59 to the Enclosure to 1CAN031203 Page 29 of 41 Item Row Tube
%TW TSP Elevation (Inches) 978 137 77 8
10S
-0.65 979 137 77 8
13S
-0.59 980 138 77 8
11S 0.52 981 139 64 8
12S
-0.65 982 139 74 8
12S 0.54 983 140 12 8
14S 0.3 984 140 65 8
11S
-0.65 985 141 14 8
12S 0.32 986 141 62 8
14S 0.3 987 143 56 8
13S 0.48 988 144 52 8
13S 0.55 989 145 33 8
13S 0.35 990 146 20 8
10S
-0.07 991 146 37 8
10S 0.11 992 146 40 8
11S
-0.71 993 149 4
8 12S
-0.69 994 151 7
8 12S
-0.73 995 151 7
8 13S 0.28 996 2
1 7
11S
-0.72 997 2
2 7
14S
-0.78 998 3
2 7
10S 0.51 999 3
3 7
10S 0.5 1000 7
40 7
10S 0.45 1001 8
43 7
13S
-0.74 1002 8
53 7
10S 0.54 1003 8
54 7
10S 0.53 1004 9
55 7
10S 0.49 1005 9
59 7
11S 0.49 1006 10 45 7
14S 0.24 1007 11 61 7
10S 0.49 1008 12 65 7
10S 0.49 1009 14 68 7
10S 0.43 1010 14 69 7
10S 0.45 1011 15 24 7
10S 0.38 1012 15 25 7
10S 0.37 to the Enclosure to 1CAN031203 Page 30 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1013 15 30 7
14S
-0.87 1014 15 78 7
08S
-0.63 1015 16 67 7
09S
-0.72 1016 16 68 7
10S 0.46 1017 16 72 7
14S
-0.76 1018 19 10 7
10S 0.4 1019 20 9
7 14S
-0.9 1020 20 54 7
08S 0.5 1021 20 81 7
13S
-0.8 1022 20 81 7
14S
-0.84 1023 21 42 7
08S 0.45 1024 21 47 7
08S 0.5 1025 21 48 7
08S 0.45 1026 21 89 7
10S
-0.7 1027 22 38 7
08S 0.46 1028 22 56 7
07S 0.46 1029 22 60 7
08S 0.5 1030 22 62 7
08S 0.5 1031 23 56 7
08S 0.5 1032 25 35 7
08S 0.45 1033 25 55 7
08S 0.48 1034 25 72 7
08S 0.47 1035 26 31 7
08S 0.47 1036 26 34 7
08S 0.48 1037 26 36 7
08S 0.41 1038 26 45 7
08S 0.47 1039 26 46 7
07S 0.45 1040 26 46 7
08S 0.49 1041 27 19 7
10S 0.35 1042 27 27 7
08S 0.45 1043 28 66 7
08S 0.47 1044 28 67 7
08S 0.49 1045 28 68 7
08S 0.49 1046 30 32 7
08S 0.47 1047 30 82 7
08S 0.49 to the Enclosure to 1CAN031203 Page 31 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1048 31 37 7
06S
-0.54 1049 31 73 7
08S 0.45 1050 31 77 7
08S
-0.69 1051 31 98 7
08S
-0.66 1052 32 32 7
08S
-0.67 1053 32 77 7
08S 0.45 1054 34 90 7
08S 0.5 1055 35 89 7
08S 0.53 1056 36 38 7
08S 0.48 1057 36 97 7
08S 0.48 1058 37 114 7
11S
-0.54 1059 38 39 7
08S 0.5 1060 39 27 7
08S 0.47 1061 39 28 7
07S 0.54 1062 41 68 7
04S 0.57 1063 42 24 7
08S 0.4 1064 44 100 7
08S 0.55 1065 45 113 7
09S 0.5 1066 45 115 7
10S 0.51 1067 47 7
7 10S 0.15 1068 49 87 7
04S 0.58 1069 49 113 7
09S
-0.68 1070 50 8
7 13S 0.28 1071 50 20 7
08S 0.44 1072 50 105 7
08S 0.54 1073 50 116 7
10S 0.51 1074 52 114 7
13S
-0.76 1075 52 120 7
13S
-0.55 1076 54 23 7
08S 0.39 1077 54 120 7
10S 0.45 1078 54 122 7
10S 0.51 1079 55 4
7 13S
-0.81 1080 55 116 7
13S
-0.62 1081 56 125 7
10S 0.59 1082 57 20 7
08S 0.42 to the Enclosure to 1CAN031203 Page 32 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1083 58 18 7
09S
-0.67 1084 58 127 7
10S 0.59 1085 59 126 7
10S 0.59 1086 60 125 7
10S 0.5 1087 60 125 7
11S 0.61 1088 61 122 7
13S
-0.69 1089 61 125 7
09S 0.54 1090 61 126 7
10S 0.56 1091 61 130 7
10S 0.61 1092 62 5
7 14S
-0.81 1093 62 110 7
08S 0.53 1094 68 110 7
08S 0.51 1095 68 126 7
09S
-0.54 1096 70 130 7
12S 0.5 1097 71 1
7 12S
-0.76 1098 71 116 7
08S 0.54 1099 71 121 7
09S 0.52 1100 72 128 7
12S 0.5 1101 74 114 7
08S 0.52 1102 75 129 7
12S 0.54 1103 75 132 7
12S 0.56 1104 76 123 7
09S 0.49 1105 77 120 7
09S 0.53 1106 77 126 7
09S 0.54 1107 78 4
7 10S 0.11 1108 78 114 7
08S 0.57 1109 78 118 7
08S 0.59 1110 79 123 7
09S 0.53 1111 82 22 7
08S 0.43 1112 82 112 7
08S 0.55 1113 82 114 7
08S 0.55 1114 82 122 7
09S 0.51 1115 82 131 7
12S
-0.51 1116 83 116 7
08S 0.56 1117 84 115 7
08S 0.54 to the Enclosure to 1CAN031203 Page 33 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1118 85 111 7
08S 0.57 1119 85 125 7
09S
-0.56 1120 85 129 7
09S
-0.55 1121 87 119 7
09S 0.52 1122 89 111 7
08S 0.57 1123 89 126 7
14S 0.54 1124 90 112 7
09S 0.5 1125 91 116 7
09S 0.51 1126 92 109 7
08S 0.54 1127 92 118 7
09S 0.55 1128 93 107 7
08S 0.56 1129 93 111 7
08S 0.58 1130 93 125 7
14S 0.45 1131 95 108 7
08S 0.53 1132 95 109 7
08S 0.56 1133 95 111 7
08S 0.58 1134 95 116 7
09S 0.53 1135 96 110 7
08S 0.6 1136 96 120 7
09S 0.56 1137 97 116 7
09S
-0.63 1138 97 117 7
09S 0.54 1139 97 119 7
09S 0.58 1140 98 6
7 10S 0.24 1141 98 110 7
08S 0.58 1142 99 105 7
08S 0.58 1143 100 7
7 10S 0.04 1144 100 99 7
08S 0.51 1145 101 111 7
09S
-0.56 1146 101 117 7
14S 0.54 1147 101 120 7
13S 0.54 1148 103 110 7
08S 0.58 1149 104 99 7
10S 0.5 1150 104 105 7
08S 0.58 1151 104 106 7
08S 0.58 1152 105 104 7
08S 0.56 to the Enclosure to 1CAN031203 Page 34 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1153 106 102 7
08S 0.56 1154 107 101 7
08S 0.52 1155 107 102 7
08S 0.56 1156 107 114 7
14S 0.52 1157 113 95 7
08S 0.56 1158 113 96 7
08S 0.58 1159 114 22 7
08S 0.44 1160 118 3
7 12S
-0.76 1161 118 4
7 03S 0.54 1162 119 26 7
08S 0.43 1163 119 87 7
08S
-0.6 1164 120 32 7
08S 0.41 1165 122 99 7
09S
-0.52 1166 123 78 7
08S 0.56 1167 123 98 7
09S
-0.52 1168 124 32 7
08S 0.46 1169 124 40 7
08S 0.5 1170 125 98 7
10S 0.26 1171 126 73 7
08S 0.54 1172 128 28 7
08S 0.47 1173 128 66 7
08S 0.53 1174 129 29 7
08S 0.43 1175 129 38 7
08S 0.47 1176 129 83 7
09S 0.48 1177 129 90 7
14S 0.46 1178 130 32 7
08S 0.45 1179 130 34 7
10S
-0.74 1180 130 69 7
08S
-0.64 1181 131 83 7
09S 0.48 1182 131 83 7
11S
-0.63 1183 132 38 7
08S 0.39 1184 132 88 7
09S 0.54 1185 133 9
7 07S
-0.68 1186 133 84 7
12S
-0.67 1187 135 77 7
09S 0.47 to the Enclosure to 1CAN031203 Page 35 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1188 136 80 7
13S 0.5 1189 137 8
7 11S
-0.78 1190 137 80 7
11S 0.52 1191 138 9
7 14S
-0.84 1192 140 10 7
14S 0.24 1193 141 6
7 13S
-0.75 1194 141 12 7
15S
-0.85 1195 141 13 7
10S
-0.72 1196 141 16 7
14S
-0.83 1197 141 58 7
14S
-0.63 1198 141 62 7
13S
-0.56 1199 141 63 7
12S 0.57 1200 143 12 7
13S 0.33 1201 143 56 7
13S
-0.63 1202 145 35 7
10S 0.28 1203 147 21 7
14S
-0.83 1204 147 26 7
11S
-0.78 1205 149 14 7
10S 0.46 1206 150 16 7
12S 0.39 1207 2
5 6
10S 0.49 1208 3
12 6
10S
-0.66 1209 4
2 6
10S 0.51 1210 6
3 6
10S 0.47 1211 6
43 6
10S 0.53 1212 9
14 6
10S 0.41 1213 9
54 6
10S 0.52 1214 11 46 6
13S
-0.72 1215 11 49 6
14S
-0.79 1216 12 1
6 11S
-0.7 1217 13 10 6
14S
-0.81 1218 13 62 6
10S 0.45 1219 18 54 6
08S 0.48 1220 20 80 6
14S 0.37 1221 21 60 6
07S 0.49 1222 22 41 6
08S
-0.73 to the Enclosure to 1CAN031203 Page 36 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1223 22 63 6
08S 0.49 1224 26 33 6
08S 0.45 1225 27 34 6
07S 0.48 1226 28 78 6
08S 0.45 1227 30 77 6
07S 0.47 1228 30 79 6
08S 0.47 1229 31 23 6
08S 0.47 1230 31 36 6
10S
-0.72 1231 31 77 6
07S 0.51 1232 31 77 6
08S 0.51 1233 33 88 6
07S 0.49 1234 34 85 6
08S 0.48 1235 36 40 6
08S 0.48 1236 37 27 6
08S 0.45 1237 37 83 6
08S 0.49 1238 37 91 6
08S 0.51 1239 38 38 6
08S 0.49 1240 38 115 6
10S
-0.56 1241 41 22 6
08S 0.43 1242 43 100 6
08S 0.55 1243 43 114 6
09S 0.48 1244 44 1
6 10S 0.45 1245 46 103 6
07S 0.53 1246 49 102 6
08S 0.53 1247 53 104 6
08S 0.53 1248 53 124 6
10S 0.76 1249 55 26 6
08S 0.48 1250 56 25 6
08S 0.46 1251 57 126 6
10S 0.56 1252 65 114 6
08S 0.54 1253 66 119 6
09S 0.56 1254 67 6
6 13S
-0.78 1255 67 129 6
10S 0.58 1256 68 111 6
08S 0.54 1257 68 114 6
08S 0.58 to the Enclosure to 1CAN031203 Page 37 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1258 68 117 6
09S 0.54 1259 68 124 6
09S 0.49 1260 68 130 6
12S 0.5 1261 69 114 6
08S 0.56 1262 70 20 6
08S 0.44 1263 70 124 6
09S 0.52 1264 73 120 6
09S 0.54 1265 73 132 6
12S 0.54 1266 74 128 6
09S
-0.54 1267 77 46 6
08S 0.54 1268 79 126 6
09S
-0.63 1269 79 126 6
09S 0.52 1270 81 132 6
09S
-0.49 1271 82 116 6
09S 0.51 1272 82 120 6
08S 0.55 1273 83 127 6
09S
-0.6 1274 84 112 6
08S 0.6 1275 86 20 6
08S
-0.72 1276 86 20 6
08S 0.39 1277 86 109 6
08S 0.57 1278 88 115 6
09S 0.49 1279 91 112 6
08S 0.58 1280 92 24 6
08S
-0.7 1281 92 129 6
12S
-0.52 1282 94 115 6
09S 0.52 1283 95 117 6
09S 0.56 1284 96 114 6
09S 0.52 1285 97 26 6
08S 0.49 1286 97 124 6
14S 0.52 1287 98 107 6
08S 0.54 1288 98 117 6
09S 0.62 1289 99 116 6
13S
-0.65 1290 100 108 6
08S 0.56 1291 101 22 6
08S 0.43 1292 102 105 6
08S 0.58 to the Enclosure to 1CAN031203 Page 38 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1293 104 112 6
09S 0.5 1294 104 118 6
14S 0.54 1295 105 29 6
08S 0.48 1296 105 115 6
10S 0.54 1297 106 114 6
14S 0.52 1298 107 117 6
11S
-0.65 1299 109 23 6
08S 0.42 1300 109 26 6
08S 0.46 1301 109 98 6
08S 0.58 1302 109 99 6
08S 0.52 1303 112 28 6
08S 0.37 1304 114 115 6
13S 0.58 1305 115 97 6
08S 0.56 1306 118 111 6
13S
-0.54 1307 119 26 6
08S
-0.76 1308 120 50 6
08S 0.52 1309 120 104 6
11S 0.54 1310 122 104 6
12S 0.54 1311 123 21 6
08S 0.43 1312 125 96 6
09S
-0.54 1313 125 100 6
12S
-0.63 1314 127 74 6
08S 0.54 1315 127 98 6
07S 0.51 1316 128 53 6
08S 0.53 1317 129 93 6
12S 0.52 1318 130 48 6
08S 0.5 1319 130 86 6
11S 0.5 1320 134 78 6
09S 0.49 1321 134 85 6
13S 0.54 1322 136 80 6
07S 0.53 1323 137 1
6 12S 0.28 1324 139 7
6 10S
-0.68 1325 139 72 6
12S
-0.59 1326 141 61 6
13S
-0.61 1327 141 64 6
12S 0.5 to the Enclosure to 1CAN031203 Page 39 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1328 144 38 6
09S
-0.63 1329 145 47 6
14S
-0.7 1330 146 33 6
10S 0.15 1331 147 27 6
10S 0.07 1332 2
3 5
10S 0.49 1333 2
6 5
10S
-0.65 1334 2
31 5
12S
-0.8 1335 3
8 5
08S
-0.65 1336 11 64 5
08S
-0.69 1337 15 67 5
13S
-0.77 1338 18 19 5
14S 0.28 1339 19 49 5
08S
-0.68 1340 20 50 5
07S
-0.7 1341 20 51 5
07S
-0.7 1342 20 84 5
13S 0.35 1343 24 11 5
10S 0.39 1344 24 49 5
08S
-0.68 1345 25 41 5
08S
-0.72 1346 27 68 5
08S 0.45 1347 28 82 5
08S 0.47 1348 30 34 5
08S 0.47 1349 36 37 5
07S 0.48 1350 39 25 5
08S 0.49 1351 40 31 5
08S 0.49 1352 40 93 5
08S
-0.62 1353 41 25 5
08S
-0.72 1354 42 25 5
08S 0.48 1355 45 29 5
08S 0.49 1356 45 101 5
08S 0.53 1357 46 103 5
08S 0.53 1358 49 20 5
08S 0.43 1359 49 85 5
06S 0.56 1360 49 113 5
09S 0.51 1361 53 1
5 06S 0.48 1362 54 22 5
08S 0.47 to the Enclosure to 1CAN031203 Page 40 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1363 57 17 5
08S 0.41 1364 58 129 5
12S
-0.65 1365 61 125 5
14S
-0.52 1366 64 124 5
09S 0.56 1367 66 37 5
08S 0.59 1368 70 114 5
08S 0.56 1369 72 131 5
09S
-0.54 1370 75 25 5
08S 0.39 1371 75 131 5
11S 0.61 1372 77 18 5
08S 0.47 1373 78 129 5
06S 0.57 1374 85 29 5
08S 0.54 1375 90 109 5
08S 0.6 1376 91 110 5
08S 0.54 1377 91 126 5
14S 0.5 1378 93 21 5
08S 0.46 1379 93 23 5
08S 0.48 1380 94 126 5
09S 0.52 1381 96 116 5
09S 0.52 1382 97 22 5
08S 0.45 1383 98 124 5
10S 0.28 1384 99 4
5 10S 0.09 1385 100 123 5
12S 0.52 1386 101 104 5
08S 0.54 1387 104 108 5
08S 0.58 1388 105 5
5 10S 0.11 1389 110 25 5
08S 0.46 1390 117 112 5
11S
-0.54 1391 118 28 5
08S 0.44 1392 128 28 5
07S 0.46 1393 131 82 5
09S
-0.56 1394 139 57 5
09S
-0.53 1395 140 12 5
15S 0.26 1396 141 54 5
11S
-0.59 1397 148 32 5
13S 0.43 to the Enclosure to 1CAN031203 Page 41 of 41 Item Row Tube
%TW TSP Elevation (Inches) 1398 23 38 4
08S 0.45 1399 39 28 4
08S 0.52 1400 44 25 4
08S 0.49 1401 45 109 4
08S 0.51 1402 49 7
4 13S 0.23 1403 67 125 4
09S
-0.56 1404 83 4
4 10S 0
1405 87 28 4
08S 0.5 1406 108 2
4 10S 0.13 1407 111 19 4
08S 0.46 1408 126 40 4
08S 0.47 1409 150 6
4 13S
-0.72 1410 22 58 3
09S
-0.68 1411 41 23 3
09S
-0.72 1412 61 129 3
11S
-0.54 1413 76 4
3 10S
-0.02 1414 81 6
3 14S 0.3