Areva Document No. 51-9177314-000, Brunswick Unit 2 Cycle 20 SLMCPR Analysis with SAFLIM3D Methodology, Enclosure 14 to BSEP 12-0031
ML12076A085
Person / Time
Site: Brunswick  
Issue date: 02/17/2012
From: Carr D
AREVA, AREVA NP
To:
Office of Nuclear Reactor Regulation
References
BSEP 12-0031 51-9177314-000
Download: ML12076A085 (15)


Text

BSEP 12-0031 4 AREVA Document No. 51-91773 14-000, "Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM31D Methodology (Nonproprietary Version)"

_..otroled oCL101n~n A

AREVA 20004-018 (10/18/2010)

AREVA NP Inc.

ENGINEERING INFORMATION RECORD Document No:

51 9177314 -

000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version)

Page 1 of 10

.....U.Dled Documentr A

AREVA 20004-018 (10/18/2010) 51-9177314-000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version)

Safety Related?

M YES F-1NO Does this document contain assumptions requiring verification?

-- YES 0

NO Does this document contain Customer Required Format?

FIYES NO Signature Block P/LP, R/LR, Pages/Sections Name and AIA-CRF, Prepared/Reviewed/

Title/Discipline Signature A/A-CRI Date Approved or Comments D.G. Carr, Supervisor

(

P Thermal-Hydraulics Richland o

,'V All D.R. Tinkler, Engineer

/

/

R Thermal-Hydraulics Richland D.W. Pruitt, Manager A/A-CRI

-'7!/f-2 Thermal-Hydraulics Richland A.B. Meginnis, Manager A

F

/ Z 0/

Product Licensing A,

12 2

7 Note:

P/LP designates Preparer (P), Lead Preparer (LP)

R/LR designates Reviewer (R), Lead Reviewer (LR)

A/A-CRF designates Approver (A), Approver of Customer Requested Format (A-CRF)

A/A-CRI designates Approver (A), Approver - Confirming Reviewer Independence (A-CRI)

Record of Revision Revision Pages/Sections/

Brief Description /

No.

Paragraphs Changed Change Authorization 000 All Initial issue of document Page 2

C. '7_%11 d Documennt 51-9177314-000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version) 1.0 Purpose Reference 1 presents an AREVA methodology for determining the safety limit minimum critical power ratio (SLMCPR) that was recently approved by the NRC. The methodology is an update or extension of the previously approved methodology presented in Reference 2. The SLMCPR methodology was updated to incorporate full implementation of the ACE critical power correlation (References 3 and 4), a realistic fuel channel bow model (Reference 5), and expanded coupling with the MICROBURN-B2 core simulator (Reference 6). More detailed descriptions of these improvements are discussed in Reference 1. The purpose of this report is to provide SLMCPR results for Brunswick Unit 2 Cycle 20 using the Reference 1 methodology to support a change in the list of approved methodologies in the Technical Specifications and also a change in the Technical Specification SLMCPR values for two-loop operation (TLO) and single-loop operation (SLO).

2.0 Methodology The analysis presented in this document used the methodology presented in Reference 1. The SLMCPR is defined as the minimum value of the critical power ratio which ensures that at least 99.9%

of the fuel rods in the core are expected to avoid boiling transition during normal operation or an anticipated operational occurrence (AOO). The SLMCPR is determined using a statistical analysis that employs a Monte Carlo process that perturbs key input parameters used in the calculation of MCPR.

The set of uncertainties used in the statistical analysis include both fuel-related and plant-related uncertainties.

The SLMCPR analysis is performed with a power distribution that conservatively represents expected reactor operating states that could both exist at the operating limit MCPR (OLMCPR) and produce a MCPR equal to the SLMCPR during an AOO. [

I In the AREVA methodology, the effects of channel bow on the critical power performance are accounted for in the SLMCPR analysis. Reference 1 discusses the application of a realistic channel bow model.

Page 3

Oocý 11 et-t 51-9177314-000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version) 3.0 Analysis The core loading and cycle depletion from the Brunswick Unit 2 Cycle 20 (BRK2-20) fuel cycle design report (Reference 7) was used as the basis of the SLMCPR analysis. Figure 1 presents the core loading, including the assembly type, the cycle the fuel was originally loaded, and the number of assemblies. The BRK2-20 core is made up of ATRIUM TM 1OXM*, ATRIUM-10, and GE14 fuel.

Analyses were performed [

] for the Brunswick power/flow map for MELLLA operation as shown in Figure 2. The BSP regions shown in the power/map are based on the methods discussed in Reference 8. The radial power distribution [

] is presented in Figure 3.

The ACE/ATRIUM 10XM critical power correlation (Reference 4) is used for the ATRIUM 1OXM fuel while the SPCB critical power correlation (Reference 9) is used for the ATRIUM-10 and GE14 fuel. The application of the SPCB critical power correlation to GE14 fuel follows the indirect process described in Reference 10.

The fuel-and plant-related uncertainties used in the BRK2-20 SLMCPR analysis are presented in Table 1. The radial and nodal power uncertainties used in the analysis include the effects of up to 40%

of the TIP channels out-of-service, up to 50% of the LPRMs out-of-service, and a 2500 effective full power hour (EFPH) LPRM calibration interval.

The BRK2-20 SLMCPR analysis supports a TLO SLMCPR of 1.06 and an SLO SLMCPR of 1.08.

Table 2 presents a summary of the analysis results including the SLMCPR and the percentage of rods expected to experience boiling transition. The percentages of the total number of fuel rods predicted to experience boiling transition in the overall Monte Carlo statistical evaluation associated with each nuclear fuel type are presented in Table 3. The results are for the [

]

4.0 Discussion of Results Results of the SLMCPR analysis using the Reference 2 methodology based on the same BRK2-20 design step-through and the same fuel-and plant-related uncertaintiest are shown in Table 4. The results show a significant decrease in both the TLO and SLO SLMCPR limits with the Reference 1 methodology. The SLMCPR differences are primarily a result of the following differences in the methodologies:

Implementation of the realistic channel bow model Explicit use of the [

] as a result of the expanded coupling with MICROBURN-B2 ATRIUM is a trademark of AREVA NP.

t[

Page 4

Clc: rtrollec DOCU1rni:11-!V 51-9177314-000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version)

The improved SLMCPR results with the Reference 1 methodology are consistent with the results presented in Tables 4-1 and 4-3 of Reference 1.

5.0 References

1.

ANP-1 0307PA Revision 0, AREVA MCPR Safety Limit Methodology for Boiling Water Reactors, AREVA NP, June 2011.

2.

ANF-524(P)(A) Revision 2 and Supplements 1 and 2, ANF Critical Power Methodology for Boiling Water Reactors, Advanced Nuclear Fuels Corporation, November 1990.

3.

ANP-10249PA Revision 1, ACE/A TRIUM-1O Critical Power Correlation, AREVA NP, September 2009.

4.

ANP-10298PA Revision 0, ACE/ATRIUM IOXM Critical Power Correlation, AREVA NP, March 2010.

5.

BAW-1 0247PA Revision 0, Realistic Thermal-Mechanical Fuel Rod Methodology for Boiling Water Reactors, AREVA NP, February 2008.

6.

EMF-2158(P)(A) Revision 0, Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4 / MICROBURN-B2, Siemens Power Corporation, October 1999.

7.

ANP-2920(P) Revision 0, Brunswick Unit 2 Cycle 20 Fuel Cycle Design, AREVA NP, May 2010.

8.

0G02-0119-260, Backup Stability Protection (BSP) for Inoperable Option Ill Solution, GE Nuclear Energy, July 17, 2002.

9.

EMF-2209(P)(A) Revision 3, SPCB Critical Power Correlation, AREVA NP, September 2009.

10.

EMF-2245(P)(A) Revision 0, Application of Siemens Power Corporation's Critical Power Correlations for Co-Resident Fuel, Siemens Power Corporation, August 2000.

11.

EMF-2493(P), MICROBURN-B2 Based Impact of Failed/Bypassed LPRMs and TIPs, Extended LPRM Calibration Interval, and Single Loop Operation on Measured Radial Bundle Power Uncertainty, AREVA NP, December 2000.

12.

NEDO-20340, Process Computer Performance Evaluation Accuracy, General Electric, June 1974.

13.

NEDO-1 0958-A, General Electric BWR Thermal Analysis Basis (GETAB): Data, Correlation and Design Application, General Electric, January 1977.

14.

NEDO-24344, Brunswick Steam Electric Plant Units I and 2 Single-Loop Operation, General Electric, September 1981.

15.

Letter, H.D. Curet (AREVA) to H.J. Richings (NRC), "POWERPLEX Core Monitoring: Failed or Bypassed Instrumentation and Extended Calibration," HDC:96:012, May 6, 1996 (38-9043714-000).

16.

0B21-1305 Revision 1, "Core Monitoring LPRM Uncertainty and Sensitivity Decay," Progress Energy, March 2009 (NRC Accession Number ML092370285).

Page 5

Cor! trm le Dc',~~

51-9177314-000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version)

Table 1 Fuel-and Plant-Related Uncertainties for BRK2-20 SLMCPR Analyses Parameter Uncertainty Reference Fuel-Related Uncertainties

[

Plant-Related Uncertainties Feedwater flow rate 1.8%§ 13 Feedwater temperature 0.8%§ 13 Core pressure 0.8%§-**

12 Total core flow rate TLO 2.5%

13 SLO 6.0%

14 Values from Reference 11 are a result of the application of the methodology discussed in Reference 15 to the base uncertainties presented in Reference 6. The uncertainties presented support operation with up to 50% of the LPRMs out-of-service, up to 40% of the TIP channels out-of-service, and a 2500 EFPH LPRM calibration interval. The bases of these values include a core monitoring LPRM detector uncertainty of 4.3% from Reference 16.

§ Referenced plant uncertainties were conservatively rounded up to the nearest 0.1% before use.

The core pressure uncertainty is taken in Reference 12 to be a more conservative value than accepted in Reference 13; therefore, the more conservative value is used.

Page 6

Co&,TArolled Docu..-ent 51-9177314-000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version)

Table 2 BRK2-20 Results Summary for SLMCPR Analysis (Reference I SAFLIM3D Methodology)

Percentage of Rods SLMCPR in Boiling Transition TLO - 1.06 0.090 SLO - 1.08 0.088 Table 3 Contribution of Total Predicted Rods in BT by Nuclear Fuel Type Contribution of Total Rods Nuclear Predicted To Be Fuel Fuel Burnup in BT (%)

Type Design Status TLO SLO 14 GE14 Twice burned

[

15 GE14 Twice burned 16 GE14 Twice burned 30 ATRIUM-10 Once burned 31 ATRIUM-10 Once burned 32 ATRIUM-10 Once burned 33 ATRIUM 1OXM Fresh 34 ATRIUM 10XM Fresh Table 4 BRK2-20 Results Summary for SLMCPR Analysis (Reference 2 SAFLIM2 Methodology)

Percentage of Rods SLMCPR in Boiling Transition TLO - 1.11 0.092 SLO - 1.13 0.076 Page 7

n e-N

.L ýJOr(Aed Dou..

n-51-9177314-000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version)

J:

1 2

3 4

5 6

7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 I: 1 2

3 4

5 6

7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 15 15 30 15 30 16 30 16 30 15 30 15 30 16 30 16 30 15 30 15 30 16 15 15 16 14 30 15 30 16 30 30 33 33 33 31 33 33 33 33 31 33 31 33 33 31 33 33 33 30 33 16 30 15 30 15 30 15 16 15 15 15 15 16 30 30 16 33 30 33 30 33 30 33 34 33 33 31 33 31 34 31 34 31 34 31 34 31 34 32 34 31 34 34 31 34 31 34 32 34 31 34 31 34 31 33 31 34 33 33 31 30 33 34 33 30 33 16 33 30 16 30 30 15 15 15 15 16 30 33 33 31 34 31 34 31 34 31 31 34 31 34 31 34 31 33 33 30 16 15 15 15 30 30 30 33 33 33 33 31 31 34 34 31 31 34 34 32 32 34 34 32 31 34 34 32 34 32 31 34 34 32 32 34 34 32 31 34 34 31 31 34 33 31 33 33 30 33 30 30 16 30 31 33 34 31 34 31 34 32 34 32 34 34 32 34 32 34 31 34 31 34 33 31 30 16 30 33 33 31 34 32 34 31 34 32 34 32 32 34 32 34 31 34 32 34 31 33 33 30 15 30 33 31 34 31 34 31 34 32 34 32 32 34 32 34 32 34 31 34 31 34 31 33 30 15 30 33 31 34 31 34 31 34 32 34 32 34 32 32 34 32 34 31 34 31 34 31 33 30 15 16 16 30 30 33 31 33 33 31 34 34 31 32 34 34 31 31 34 34 32 32 34 34 32 32 34 32 34 34 32 32 34 34 32 31 34 34 31 32 34 34 31 31 34 33 33 33 31 30 30 16 16 14 30 33 33 31 34 31 34 32 34 32 34 32 32 34 32 34 32 34 31 34 31 33 33 30 15 15 30 30 33 33 31 34 31 34 32 34 31 34 34 31 34 32 34 31 34 31 33 33 30 30 15 15 16 30 33 33 31 34 31 34 31 34 31 31 34 31 34 31 34 31 33 33 30 16 15 15 30 30 33 34 31 34 31 34 32 34 34 32 34 31 34 31 34 33 30 30 15 15 15 30 16 15 33 16 16 30 33 30 33 30 30 33 33 30 31 33 33 34 31 33 31 34 33 34 31 33 31 34 31 31 34 31 34 31 33 31 34 33 34 31 33 31 33 33 33 33 30 33 30 30 30 33 30 33 16 16 30 16 15 15 15 15 15 15 16 30 33 31 33 33 33 33 31 33 30 16 15 15 15 16 30 15 30 16 30 16 30 15 30 15 30 15 30 16 30 16 30 15 30 15 16 15 15 16 16 15 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Nuclear Fuel Cycle Number of Fuel Type Description Loaded Assemblies 14 GE14 18 2

15 GE14 18 55 16 GE14 18 39 30 ATRIUM-10 19 84 31 ATRIUM-10 19 104 32 ATRIUM-10 19 50 33 ATRIUM 1OXM 20 96 34 ATRIUM 1OXM 20 130 Figure 1 Brunswick Unit 2 Cycle 20 Core Loading Map Page 8

51-9177314-000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version) 110.0 100.0 90.0 80.0 70.0 60.0 0

a.

50.0 40.0 30.0 20.0 10.0 0.0 0.0 7.7 15.4 23.1 30.8 38.5 46.2 53.9 61.6 69.3 77.0 84.7 92.4 Mlbs/hr Core Flow 0

10 20 30 40 50 60 70 80 90 100 110 120 % Core Flow Figure 2 Brunswick Unit 2 PowerlFlow Map With Nominal Feedwater Temperature BSP Regions Page 9

Uorifirolled 51-9177314-000 Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology (Nonproprietary Version) 2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 J: 1 0.298 0.369 0.425 0.447 0.438 0.437 0.446 0.427 0.377 0.304 2

3 4

5 6

7 8

9 10 11 12 13 0.387 0.608 0.695 0.744 0.774 0.793 0.793 0.774 0.745 0.698 0.615 0.434 0.263 0.362 0.485 0.640 0.848 1.071 0.941 1.144 1.151 1.151 1.145 0.943 1.075 0.852 0.658 0.490 0.357 0.268 0.295 0.474 0.667 0.806 0.929 1.179 1.252 1.284 1.292 1.076 1.076 1.293 1.286 1.254 1.183 0.933 0.809 0.667 0.477 0.293 0.260 0.473 0.667 0.993 0.971 1.239 1.306 1.118 1.350 1.130 1.347 1.347 1.131 1.350 1.120 1.308 1.241 0.972

0. 995 0.666 0.473 0.267 0.354 0.666 0.993 0.991 1.275 1.337 1.138 1.368 1.154 1.371 1.147 1.148 1.371 1.154 1.368 1.139 1.338 1.276 0.990 0.994 0.665 0.353 0.485 0.806 0.974 1.275 1.342 1.153 1.390 1.163 1.378 1.132 1.376 1.376 1.131 1.379 1.163 1.390 1.153 1.342 1.275 0.972 0.804 0.486 0.406 0.643
0. 929 1.239 1.337 1.150 1.384 1.172 1.358 1.105 1.307 1.112 1.112 1.307
1. 104 1.358 1.172 1.383 1.149 1.336 1.238 0.920 0.643 0.406 0.300 0.611 0.848 1.180 1.306 1.139 1.388 1.174 1.372 1.078 1.034 0.863 1.247 1.247 0.863 1.035 1.079 1.372 1.173 1.386 1.136 1.305 1.179 0.848 0.615 0.300 0.376 0.697 1.071 1.251 1.127 1.367 1.166 1.389 1.127 1.292 0.848 0.997 1.002 1.002 0.998 0.850 1.293 1.126 1.388 1.165 1.365 1.124 1.251 1.071 0.696 0.370 0.425 0.744 0.935 1.279 1.347 1.149 1.376 1.154 1.364 1.105 1.250 1.007 1.221 1.224 1.011 1.253 1.106 1.364 1.152 1.375 1.147 1.347 1.279 0.934 0.744
0. 425 0.445 0.771 1.137 1.279 1.117 1.328 1.086 1.319 1.128 1.337 1.067 1.254 1.011 1.023 1.267 1.070 1.338 1.126 1.317 1.084 1.327 1.116 1.279 1.137 0.772 0.447 0.434 0.788 1.140 1.058 1.304 1.077 1.063 0.896 1.304 1.094 1.308 1.040 1.017 1.245 1.047 1.310 1.092 1.302 0.895 1.061 1.075 1.303 1.058 1.140 0.789 0.436 2

3 4

5 6

7 10 11 12 13 J:14 15 16 17 18 19 20 21 22 23 24 25 26 2

3 4

5 6

7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 0.429 0.788 1.139 1.057 1.303 1.077 1.062 0.895 1.304 1.094 1.311 1.047 1.245 1.016 1.039 1.307 1.092 1.302 0.895 1.061 1.075 1.303 1.058 1.140 0.787 0.435 0.443 0.770 1.136 1.278 1.116 1.327 1.084 1.318 1.128 1.339 1.072 1.268 1.022 1.010 1.254 1.065 1.334 1.125 1.317 1.083 1.327 1.116 1.279 1.137 0.770 0.441 0.425 0.742 0.933 1.278 1.346 1.147 1.376 1.152 1.365 1.107 1.254 1.012 1.225 1.221 1.006 1.249 1.102 1.362 1.152 1.375 1.146 1.347 1.279

0. 935 0.743 0.425 0.363 0.695 1.069 1.250 1.125 1.366 1.166 1.389 1.127 1.294 0.849 0.998 1.003 1.001 0.997 0.848 1.292 1.126 1.388 1.166 1.366 1.125 1.251 1.071 0.697 0.377 0.298 0.608 0.846 1.180 1.306 1.136 1.387 1.174 1.373 1.079 1.035 0.863 1.247 1.247 0.863 1.034 1.078 1.372 1.173 1.388 1.137 1.307 1.180 0.847 0.610 0.301 0.405 0.642 0.931 1.240 1.337 1.148 1.384 1.172 1.358 1.104 1.307 1.112 1.112 1.307 1.105 1.358 1.172 1.384 1.149 1.337 1.240 0.930 0.642 0.405 0.488 0.809 0.975 1.276 1.342 1.152 1.390 1.163 1.379 1.131 1.376 1.377 1.132 1.379 1.162 1.391 1.152 1.343 1.276 0.973 0.808 0.487 0.360 0.669 0.996 0.990 1.276 1.337 1.137 1.368 1.152 1.371 1.148 1.148 1.372 1.154 1.369 1.137 1.338 1.276 0.991 0.995 0.667 0.356 0.264 0.488 0.669 0.995 0.971 1.240 1.307 1.118 1.350 1.129 1.347 1.347 1.130 1.350 1.119 1.307 1.240
0. 970 0.994 0.668 0.483 0.263 0.298 0.476 0.668 0.810 0.929 1.181 1.253 1.285 1.292 1.074 1.076 1.292 1.284 1.253 1.180 0.929 0.807 0.666 0.474 0.297 0.265 0.373 0.492 0.645 0.851 1.073 0.939 1.143 1.150 1.150 1.144 0.941 1.072 0.848 0.643 0.488 0.355 0.268 0.431
0. 615
0. 698 0.743 0.771 0.790 0.791 0.773 0.743 0.695 0.612 0.429 0.317 0.389 0.428 0.430 0.430 0.437 0.447 0.425 0.370 0.301 14 15 16 17 18 19 20 21 22 23 24 25 26 Figure 3 Radial Power Distribution for Brunswick Unit 2 Cycle 20 SLMCPR[

Page 10

BSEP 12-0031 6 AREVA Affidavit Regarding Withholding AREVA Document No. 51-9176342-000, "Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology - Operability Assessment (Proprietary Version)" from Public Disclosure

AFFIDAVIT STATE OF WASHINGTON

)

) ss.

COUNTY OF BENTON

)

1.

My name is Alan B. Meginnis. I am Manager, Product Licensing, for AREVA NP Inc. and as such I am authorized to execute this Affidavit.

2.

I am familiar with the criteria applied by AREVA NP to determine whether certain AREVA NP information is proprietary. I am familiar with the policies established by AREVA NP to ensure the proper application of these criteria.

3.

I am familiar with the AREVA NP information contained in the report 51-9176342-000, "Brunswick Unit 2 Cycle 20 SLMCPR Analysis With SAFLIM3D Methodology

- Operability Assessment (Proprietary Version)," dated February 2012 and referred to herein as "Document." Information contained in this Document has been classified by AREVA NP as proprietary in accordance with the policies established by AREVA NP for the control and protection of proprietary and confidential information.

4.

This Document contains information of a proprietary and confidential nature and is of the type customarily held in confidence by AREVA NP and not made available to the public. Based on my experience, I am aware that other. companies regard information of the kind contained in this Document as proprietary and confidential.

5.

This Document has been made available to the U.S. Nuclear Regulatory Commission in confidence with the request that the information contained in this Document be withheld from public disclosure. The request for withholding of proprietary information is made in accordance with 10 CFR 2.390. The information for which withholding from disclosure is

requested qualifies under 10 CFR 2.390(a)(4) "Trade secrets and commercial or financial information."

6.

The following criteria are customarily applied by AREVA NP to determine whether information should be classified as proprietary:

(a)

The information reveals details of AREVA NP's research and development plans and programs or their results.

(b)

Use of the information by a competitor would permit the competitor to significantly reduce its expenditures, in time or resources, to design, produce, or market a similar product or service.

(c)

The information includes test data or analytical techniques concerning a process, methodology, or component, the application of which results in a competitive advantage for AREVA NP.

(d)

The information reveals certain distinguishing aspects of a process, methodology, or component, the exclusive use of which provides a competitive advantage for AREVA NP in product optimization or marketability.

(e)

The information is vital to a competitive advantage held by AREVA NP, would be helpful to competitors to AREVA NP, and would likely cause substantial harm to the competitive position of AREVA NP.

The information in the Document is considered proprietary for the reasons set forth in paragraphs 6(b), 6(d) and 6(e) above.

7.

In accordance with AREVA NP's policies governing the protection and control of information, proprietary information contained in this Document have been made available, on a limited basis, to others outside AREVA NP only as required and under suitable agreement providing for nondisclosure and limited use of the information.

8.

AREVA NP policy requires that proprietary information be kept in a secured file or area and distributed on a need-to-know basis.

9.

The foregoing statements are true and correct to the best of my knowledge, information, and belief.

f Ir i.

I

,/

SUBSCRIBED before me this day of "

1 i--,

, 2012.

Susan K. McCoy NOTARY PUBLIC, STATE OF WAS'ING MY COMMISSION EXPIRES: 1/14/2016