Withdrawn NRC Generic Letter 1994-04, Voluntary Reporting of Additional Occupational Radiation Exposure Data dated September 2, 1994, has been withdrawn.

ADAMS Accession Number: ML12047A243 See Federal Register notice dated April 18, 2017.

82 FR 18316

/

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, D.C.

20555 September 2, 1994 NRC GENERIC LETTER 94-04:

VOLUNTARY REPORTING OF ADDITIONAL OCCUPATIONAL RADIATION EXPOSURE DATA Addressees All holders of operating licenses or construction permits for nuclear power reactors, radiography licensees, fuel processing licensees, fabricating and reprocessing licensees, manufacturers and distributors of byproduct material, independent spent fuel storage installations, facilities for land disposal of low-level waste, and geologic repositories for high-level waste.

Purpose The U.S. Nuclear Regulatory Commission (NRC) is issuing this generic letter to request that all addressees provide to the NRC a voluntary report containing the occupational radiation exposure data as described below.

Qackqround The provisions of § 20.2206 of 10 CFR Part 20 require seven categories of NRC licensees to submit occupational radiation exposure reports.

The seven categories are as follows:

commercial nuclear power reactors; industrial radiographers; fuel processcrs, fabricators and reprocessors; manufacturers and distributors of byproduct material; independent spent fuel storage installations; facilities for land disposal of low-level waste; and geologic repositories for high-level waste.

Each of these approximately 500 licensees submits exposure reports for each of its monitored employees.

This data is computerized by the NRC, and forms the basis for the Radiation Exposure Information Reporting System (REIRS).

An analysis of the REIRS database is presented in the annual volumes of NUREG-0713, "Occupational Radiation Exposure at Commercial Nuclear Power Reactors and Other Facilities."

The analysis provides licensees with an opportunity to compare ALARA performance at their facilities with that of similar facilities.

The data are also used to evaluate occupational doses against national and international radiation protection recommendations to determine if further reductions in the occupational dose limits in 10 CFR Part 20 are needed to achieve the recommended levels.

The REIRS database also provides a historical view of radiation exposure at NRC licensed facilities 9408290302 L?

oI

GL 94-04 September 2, 1994 Page 2 of 5 over the last quarter century.

The NRC database can be used to provide complete individual exposure history to employers to assist them in demonstrating compliance with the occupational radiation exposure requirements regarding exposure histories for required individuals.

Finally, REIRS is the largest database of radiation exposures at occupational levels.

This makes it a very valuable epidemiological resource in determining the actual risk of exposure at occupational levels.

One of the goals fulfilled through the collection of this additional data is to supplement the information available through the Part 20 reporting and recordkeeping requirements so that the information vital to carrying out epidemiological studies will be available.

This goal was stated in the statement of consideration to 10 CFR 20.1001 through 20.2402 published in the Federal Register on May 21, 1991 (56 FR 23386).

The utility of this information is in conducting such studies and the intention of the National Cancer Institute to conduct these studies was discussed in an April 20, 1994 letter to Bill M. Morris, Director of the Division of Regulatory Applications, Office of Nuclear Regulatory Research from Dr. John Boice, Chief of the Radiation Epidemiology Branch, National Cancer Institute.

In the letter, Dr. Boice states that it is the current workers who have been employed for many years who are most critical to a successful epidemiological study.

Description of Circumstances Under the previous requirements of 10 CFR Pirt 20.1 through 20.602, seven classes of licensees were required to submit termination reports containing occupational radiation exposure data for the entire period of work or employment to the NRC when individuals terminated employment or a work assignment at their facilities.

Thus, at the end of a worker's employment, the individual's entire exposure record would be part of NRC's exposure database.

In addition, these licensees were required to submit a statistical summary of the exposures of all individuals occupationally exposed at their facilities.

Under the new requirements of 10 CFR 20.1001 through 20.2402, which became mandatory on January 1, 1994, these licensees are now required to annually submit occupational radiation exposure data to the NRC for all persons occupationally exposed at their facilities, during that year, for whom monitoring is required.

Termination reports are no longer required.

Thus, as of April 1994 and every April thereafter, the required exposure data for employees for the previous year is to be submitted to the NRC.

With this change in reporting requirements, the exposure data for current employees, from the time of their initial employment to the date of implementation of the new requirements of 10 CFR Part 20.1001 through 20.2402 would not be reported.

Complete data would only be available for employees who finished their careers prior to the new requirements or new employees who only worked under the new requirements.

Complete data would not be available for any employee who worked under both the new and old reporting requirements.

This gap in the radiation exposure data would limit the usefulness of the REIRS database for

GL 94-04 September 2, 1994 Page 3 of 5 (1) epidemiology as described by Dr. Boice, (2) supporting decisions on the necessity and appropriateness of new regulatory requirements for occupational exposure, and (3) facilitating determinations by new employers of prior occupational exposure as required by 10 CFR 20.2104.

Discussion The Nuclear Regulatory Commission, as well as national and international organizations such as the International Commission on Radiation Protection (ICRP) ar. the National Commission on Radiation Protection and Measurements (NCRP),

derives information on occupational exposures from the REIRS database and uses this information to establish limits on occupational exposure to ionizing radiation.

If the REIRS database is known to be incomplete, it will not be reliable for determining actual lifetime exposures.

This will have three major consequences.

First, NRC would not be able to continue to provide complete exposure histories to individuals to facilitate the movement of transient workers from one licensee to another.

Second, actual lifetime exposures could not be determined for the occupationally exposed workers in the seven categories of licensees.

Without this information, NRC may have difficulty in evaluating whether further limitations on occupational doses are needed to achieve dose levels recommended by the ICRP.

Finally, a large reliable database, available to the National Cancer Institute for epidemiological studies on occupationally exposed workers, would not be available for decades.

The ability of agencies such as NCI to rely upon these data of doses at occupational levels would be lost.

Requested Information In an effort to provide for a complete and reliable database, the NRC is requesting that the seven classes of licensees included in the REIRS database provide a voluntary report of the data missed as a result of the change in regulations.

This report is requested to include the occupational radiation exposure data of all current licensee employees from the date of employment to the day prior to implementation of the new requirements of 10 CFR Part 20.1001 through 20.2402 which were otherwise unreported under the reporting requirements of 10 CFR 20.1-20.602.

The information requested is that normally included on NRC Form 5.

Voluntary Response Requested Within 180 days from the date of this generic letter, all addressees are requested to submit a voluntary report containing data for each monitored individual from the date of employment to the day prior to the implementation of the new requirements of 10 CFR Part 20.1001 through 20.2402.

Data previously reported on termination reports need not be included.

It is

GL 94-04 September 2, 1994 Page 4 of 5 preferable that the data be reported by monitoring year, but a single monitoring period spanning several years is acceptable.

If possible, the data should be submitted electronically.

While the NRC will accept these data in any format, a suggested format as well as an electronic format is provided in Enclosure I in an effort to simplify submission of the requested data.

The electronic format is the preferred format for the submission of the data.

In addition, a cover letter should be included which gives the name of the licensee, the NRC license number, the name of a person to contact in case there are questions, and the phone number at which that individual can be reached (the same information requested as part of NRC Form 5).

Address all reports to the U.S. Nuclear Regulatory Commission, ATTN:

REIRS Project Manager, Mail Stop T-9 C24, Washington, DC 20555.

Backfit Discussion This generic letter only requests voluntary submittal of information.

Therefore the staff has not performed a backfit analysis.

A notice of opportunity for public comment was not published in the Federal Register because of the voluntary nature of the information request.

Paperwork Reduction Act Statement The voluntary information collections contained in this request are covered by the Office of Management and Budget, clearance number 3150-0011, which expires July 31, 1997.

The public reporting burden for this voluntary collection of information is estimated to average 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information.

Send comments regarding this burden estimate or any other aspect of this voluntary collection of information, including suggestions for reducing this burden, to the Information and Records Management Branch (T-6 F33),

U.S. Nuclear Regulatory Commission, Washington, D.C. 20555, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0011), Office of Management and Budget, Washington, D.C.

20503.

Compliance with the following request for information also is purely voluntary.

The information would assist NkC ir evaluating the cost of complying with this generic letter.

GL 94-04 September 2, 1994 Page 5 of S The licensee staff time and costs to prepare the requested reports and documentation.

If you have any questions about this matter, please contact the technical contact, listed below.

Carl J. Paper ello, Director Division of Industrial and Medical Nuclear Safety Office of Nuclear Material Safety and Safeguards m rman

  • ociaý irector for Projects Office of Nuclear Reactor Regulation Attachments:

I.

Format for the Occupational Radiation Exposure Data Report

2.

List of Recently Issied NRC Generic Letters Technical contact:

Charleen T. Raddatz, RES (301) 415-6215

Attachment I GL 94-04 September 2, 1994 Page I of 4 FORMAT FOR THE OCCUPATIONAL RADIATION EXPOSURE DATA REPORT Electronic Format Electronic submittal should be on 3.5" or 5.25" PC diskettes or 8 mm magnetic tape.

Each disk, tape, or cartridge submitted should include a transmittal letter.

Each letter should contain the file name, date created, operating system, the name and phone number of a person knowledgeable about each file, any other pertinent instructions, signature, and date.

File Structure Each diskette should contain two file types.

The first file type should be a single header record which provides information about the source of the data file.

The second file type should be an exposure record for each monitoring period for each monitored individual.

Each record should contain only ASCII or EBCDIC printable characters, terminated with a carriage return (CR) and a line feed (LF).

All empty space should be padded with spaces.

Text strings are expected to be left justified in a field and numbers are expected to be right justified in a field.

GL 94-04 September 2, 1994 Page 2 of 4 Header Record (occurs only once on each diskette, tape, or cartridge)

FIELD WIDTH START END DESCRIPTION COL.

COL.

Primary Licensd 13 1

13 Primary NRC license number Preparatior, Date S

15 22 Date the record was written to the data file turmatted as 'YYYYMMDD' Licensee Name 72 24 95 Name of the NRC licensed facilitv Contact 72 97 168 Name of the person to contact for information about this data file Phone Number 14 170 183 Contact's phone number Other license 1 13 185 197 Other NRC license number Other license 2 13 199 211 Other NRC license number Other license 3 13 21 3 225 Other NRC license number Other licern.e 4 13 227 239 Other NRC license number Other license 5 13 241 253 Other NRC license number Other license 6 13 255 267 Other NRC license number Other license 7 13 269 281 Other NRC license number Other licen*e 8 13 283 295 Other NRC license number Other license 9 13 297 309 Other NRC license number Other license 10 13 31t 1 323 Other NRC license number GL 94-04 September 2, 1994 Page 3 of 4 Exposure Record (one for each individual, for each monitoring period)

FIELD WIDTH START END DESCRIPTION COL.

COL.

EmploVee_lD 12 1

12 Social Security Number (or Other ID number)

Primary License 13 1 3 25 PrimarV License Number First-NAnie 25 26 so Employee's first name (no nicknames)

Middle Instial 1

51 51 Enic)l)hye's middle initial Last Name 25 52 76 Ermiovee's last name. Titles such as "Jr" should be separated from the last name by a space. No punctuation should tvj used in the title.

Sex 1

77 77 "M' =Male. "F' = Female Birth Date 8

78 85 Emplovee's date of birth (YYY',MMDDI Monnnring Start 8

86 93 Date Monitoring began (YY' YMMDD)

Monitoring End 8

94 101 Late Monitoring ended (YYYYMMDD). If possible. report in one veea increme'nts.

The end date for the last monitoroi, period for a given indivwditir would be oi or before the day immediately prior to implementation of the revised Part 20.

WB Dise 8

102 109 Total whole bodv deep dose in rem for the eintire period, including x. gamma. end neutron dose. This should be formatted

  • 9999.999'.

Aitachment 1 GL 94-04 September 2, 1994 Page 4 of 4 If hard copy reports wire to each monitored individual:

be submitted, the following information is needed for Last First I

SSN S

Date Date D.-,te Whole Name Name n

a of Monitoring P.Monitoring Body i

x Birth Began Ended Dose t

(rem) 1-

__ __.-li--

GL 94-04 September 2, Page 1 of 1 1994 LIST OF RECENTLY ISSUED GENERIC LETTERS Generic I pttpr Date of Ilq fuiicp Sihinct

!-tir d Tn Letter 94-03 94-02 94-01 86-10, SUPP.

I 89-'0, SUPP.

6 INTERGRANULAR STRESS CORROSION CRACKING OF CORE SHROUDS IN BOILING WATER REACTORS LONG-TERM SOLUTIONS AND UPGRADE OF INTERIM OPERATING RECOMMENDATIONS FOR THERMAL-HYDRAULIC INSTABILITIES IN BOILING WATER REACTORS REMOVAL OF ACCE'ERATFD TESTING AND SPECIAL RE-PORTING REQUIREMENTS FOR EMERGENCY DIESEL GENERATORS FIRE ENDURANCE TEST ACCEPTANCE CRITEIIA FOR FIRE BARRIER SYSTEMS USED TO SEPARATE REDUNDANT SAFE SHUTDOWN TRAINS WITHIN THE SAME FIRE AREA (SUPP.

1 TO GL 86-10, "IMPLEMENTATION OF FIRE PROTECTION REQUIREMENTS")

INFORMATION ON SCHEDULE AND GROUPING, AND STAFF RESPONSES TO ADDITIONAL PUBLIC QUESTIONS 07/25/94 07/11/94 05/31/94 03/25/94 03/08/94 ALL HOLDERS OF OLs OR CPs FOR FOIL:NG WATER REACTORS EXCEPT FOR BIG ROCK POINT, WHICH DOES NCOI HAVE A CORE SHROUD.

ALL HOLDERS OF OLs FOR BOILING WATER REACTORS

  • XCEPT BIG ROCK POINT ALL HOLDERS OF OLs FOR NPRs ALL HOLDERS OF OLs OR CPs FOR NPRs ALL LICENSEES OF OPERATING NUCLEAR POWER PLANTS AND HOLDERS OF CONSTRUCTION PERMITS FOR NPRs 93-08 RELOCATION OF SPECIFICATION OF INSTRUMENT TIME LIMITS TECHNICAL TABLES OF

RESPONSE

12/29/'93 ALL HOLDERS OF OLs FOR NPRs OL

=

CP

=

NPR =

OPERATING LICENSE CONSTRUCTION PERMIT NUCLEAR POWER REACTORS

Generic Letter 94-xx "he licensee staff time and costs to prepare the requested reports and documentation If you have any questions about this matter, please contact the technical contact listed below.

Carl J. Paperiello, Director Division of Industrial and Medical Nuclear Safety Office of Nuclear Material Safety and Safeguards Roy P. Zimmerman Associate Director for Projects Office of Nuclear Reactor Regulation

Enclosures:

1. Format for the Occupational Radiation Exposure Data Report
2.

List of Recently Issued NRC Generic Letters Technical

Contact:

Charleen T. Raddatz, RES (301) 415-6215 See next page for previous concurrences - Memorandum from E.S. Beckjord, Director, Office of Nuclear Regulatory Research to E.L. Jordan, Chairman, Committee to Review Generic Requirements dated July 13, 1994.

OFFICE OGCB AB-B/DORS D:DORS/NRR D:IMNS/NMSS ADP:NRR NAME NECamobell E

11 tle BKGrimes

1) CJPaperiello RPZimmerman DATE J 08//7/94 08/1')/94 08/

/94 08/

/94 08/ /94 OFFICIAL RECORD COPY

GL 94-xx August xx, 1994 Page 5 of 5 The licensee staff time and costs to prepare the requested reports and documentation.

If you have any questions about this matter, please contact the technical contact listed below.

Carl J. Paperiello, Director Division of Industrial and Medical Nuclear Safety Office of Nuclear Material Safety and Safeguards Roy P. Zimmerman Associate Director for Projects Office of Nuclear Reactor Regulation Attachments:

1. Format for the Occupational Radiation Exposure Data Report
2.

List of Recently Issued NRC Generic Lettpr Technical contact:

Charleen T. Raddatz, RES (301) 415-6215 See next page for previous concurrences - Memorandum from E.S. Beckjord, Director, Office of Nuclear Regulatory Research to E.L. Jordan, Chairman, Committee to Review Generic Requirements dated July 13, 1994.

Reference:

Memorandum from B.M. Morris to E.L.

1994 titled "Voluntary Reporting of Radiation Exposure Data" Doolittle, dated August 11, Additional Occupational

  • See previous concurrence OFFICE
  • OGCB
  • AC:OGCB/DORS D:DORS/NRR D:IMNS/NMSS ADP:NRR NAME NECampbell ELDoolittle BKGrimes CJPaperiello RPZimmerman DATE 08/ 19/94 08/19/94 08/

194 081 4'94 08/

/94 OFFICIAL RECORD COPY

GL 04-04.

September 2, 1994 Page 5 of 5 The licensee staff time and costs to prepare the requested reports and documentation.

If you have any questions about this matter, please contact the technical contact listed below.

original sign(cd by Carl J. Paperiello, Director Division of Industrial and Medical Nuclear Safety Office of Nuclear Material Safety and Safeguards original signed by Roy P. Zimmerman Associate Director for Projects Office of Nuclear Reactor Regulation Attachments:

1. Format for the Occupational Radiation Exposure Data Report
2.

List of Recently Issued NOC Generic Letters Technical contact:

Charleen T. Raddatz, RES (301) 415-6215 See next page for previous concurrences - Memorandum from E.S. Beckjord, Director, Office of Nuclear Regulatory Research to E.L. Jordan, Chairman, Committee to Review Generic Requirements dated July 13, 1994.

Reference:

Memorandum from B. M. Morris to E. L. Doolittle, dated August 11, 1994, titled, "Voluntary Reporting of Additional Occupational Radiation Exposure Data"

  • See previous concurrence

-A+ q q I I OFFICE

  • OGCB
  • AC:OGCB/DORS D:D*i/NRR D:IM NnS ADP:NRR NAME NECampbell -ELDoo*I~ttle BKgi*mes CJ~a~pý ello*('"

RP~imnle*Prman DATE 08/19/94 08/19/94 08/1\\/94 08/O /94 04/_ /94____

OFFICIAL RECORD COPY