ML12037A049

From kanterella
Jump to navigation Jump to search
E-mail from R. Martin, NRR to C. Munson, NRO, Et Al; Subject: Info Request North Anna and Earthquakes
ML12037A049
Person / Time
Site: North Anna  
Issue date: 08/31/2011
From: Martin R
Plant Licensing Branch II
To: Rebecca Karas, Clifford Munson, George Wilson
NRC/NRO/DSEA, NRC/NRO/DSEA/RGS1, Plant Licensing Branch 1
References
FOIA/PA-2011-0357
Download: ML12037A049 (2)


Text

Martin, Robert From:

Martin, Robert Sent:

Wednesday, August 31, 2011 12:33 PM To:

Munson, Clifford; Wilson, George; Karas, Rebecca; Kammerer, Annie; Manoly, Kamal; Kulesa, Gloria; Khanna, Meena; Thomas, George; Chokshi, Nilesh

Subject:

RE: Info Request re: North Anna and Earthquakes ML040970068 (March 29, 2004) says horizontal free field for the San Simeon EQ was.05 so it doesn't lopk, like that came anywhere near Diablo's 3 EQ criteria.

From: Munson, Clifford c( *(..*

Sent: Wednesday, August 31, 2011 11:51 AM To: Wilson, George; Karas, Rebecca; Kammerer, Annie; Manoly, Kamal; Martin, Robert; Kulesa, Gloria; Khanna, Meena; Thomas, George; Chokshi, Nilesh

Subject:

RE: Info Request re: North Anna and Earthquakes I spoke with Goutam Bagchi who has been with the NRC for many years and the only OBE exceedance other than Perry and NAnna may have been Diablo Canyon (from the San Simeon earthquake?). We need to check this because I am not sure that it exceeded their OBE. Goutam believes the incident at Fermi was some damage from a tornado and not an earthquake.

Nilesh do you know more details?

Cliff From: Wilson, George Sent: Wednesday, August 31, 2011 11:24 AM To: Karas, Rebecca; Munson, Clifford; Kammerer, Annie; Manoly, Kamal; Martin, Robert; Kulesa, Gloria; Khanna, Meena; Thomas, George

Subject:

FW: Info Request re: North Anna and Earthquakes Importance: High Please assist and gather the data and answer the questions below. What plants have exceeded OBE and What plants have exceeded SSE, this information is needed by COB today. I greatly appreciate your help and support in this issue. Please send the data to me.

From: Bowman, Gregory

  • /\\--)

Sent: Wednesday, August 1, 2011 11:01 AM To: Wilson, George; Khanna, Meena

Subject:

FW: Info Request re: North Anna and Earthquakes Importance: High George and Meena, Bill Dean (who's acting for Marty this week) sent the e-mail below to Jack and Eric. The Chairman asked that we confirm which plants have experienced earthquakes exceeding the SSE (the e-mail below says OBE - I could be wrong, but I think he meant SSE - if we know both, that would be good for me to pass along, too). I need to share whatever we have with OPA and the Commission offices before the end of the day, so if you can get back to me before then, I would appreciate it.

Greg 1

t1

-V -*1W From: Dean, Bill cc*C)

Sent: Wednesday, Lgust 31, 2011 8:47 AM To: Grobe, Jack; Leeds, Eric Cc: Virgilio, Martin; Bowman, Gregory; Merzke, Daniel

Subject:

Info Request re: North Anna and Earthquakes As we discussed this morning, we need to develop some technically oriented Q and A that can help our public affairs people properly address some of the questions that they are getting. On a nearer term basis, Bill B. just came from the Chairman's office with a question the Chairman would like us to get a straight answer to all the commissioners/OPA" how many sites have exceeded OBE in the past" - I believe it is only Perry, but some are saying FERMI as well. Do we have this information definitively, and if so, can we work with the OEDO staff to get this info walked around to the Commission offices and OPA today? Thanks.

Bill 2