Maier, Bill From:

Schwarz, Jon Dlon.schwarz@nebraska.gov]

Sent :

Monday, June 27, 2011 10:29 AM To:

Berndt, Al; Canida Audie ; Fawl, Jodie; Hollingsead Greg; Imler, Earl; Kirk Phil; Maier, Bill; McCabe Ron ; Newsham, Cindy; Ryan Laurel " Valentine Norman Jansky, Doris; Jensen, Danielle; Loos, Jerry; Moon Guy; Willson, Ginger SubjIect:

Daily Event Status for Fort Calhoun Station

FYI, Outside of Scope Jon Jonathan (Jon) F. Schwarz Technical Hazards Section Supervisor Nebraska Emergency Management Agency 1300 Military Road Lincoln, NE 68508-1090 Telephone: 402-471-7420 T.:CeIl:. 402-570-79U27 Fax: '402-471-7433 From: BERCK, ALLEN Sent: Monday, June 27, 2011 8:45 AM To: Bill Pook; Dan; Eric Plautz; Jeff Clark; Jeff Theulen; Schwarz, Jon; KIRKLAND, JOHN NRC; Larry Oliver; Laurel Ryan; Paul IJohnson; Whitney Shipley; 'Stodola, Kathy [HSEMD'

Cc: BERCK, ALLEN; DEANGELIS, PETER A; HANKINS, RHONDA R; MOELLER, CHRISTOPHER 3; RELLER, MARK H; SILKE, DEENA L

Subject:

Daily Event Status for Fort Calhoun Station Fort Calhoun Flooding Status (changes from yesterday's report are in bold)

1. Reactor Status: Shutdown
2. Reactor is covered with > 23-ft of cooling water
3. Offsite power and Emergency Diesel Generators are available. Both vital buses are energized at this time.
4. Spent Fuel Pooling cooling is in service and protected.
5. Shutdown cooling is in service and protected
6. Current river level is 1006' 4" at Fort Calhoun Station - the river has lowered slightly over the last 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> due to a levee break in Iowa near Missouri Valley (plant was not impacted by the levee break). However, we do expect the river to return once that new flood plain equalizes.
7. Current Blair gauge level is 32.48 ft.
8. Early Sunday morning (June 26, 2011), one of the AuqaDams that was protecting the plant ruptured. The AquaDam was a backup (secondary) flood protection barrier. All primary barriers are intact and are providing adequate protection to the site. The station is on Emergency Diesel Generator power. Water has not entered any vital equipment, and no personnel were injured. Water has equalized onsite, repair efforts are underway, and plans are i

,ess to return to offsito AC power capabilities. We did issue a special updated FC-in n

mat s

the record was deleted in accordance with the F edom of Information 1

Act,(

  • 0-At

1188 report this morning, but have returned to shittly updates. This section of the AquaDam is expected to be repaired in a week.

9. The site has implemented procedures to protect power supplies and vital equipment. Water is onsite, and flood barriers are protecting vital equipment.
10. No release of radioactivity has occurred.
1. Fort Calhoun has declared a Notification of Unusual Event at 08:00 6/6/11.
2. Backup evacuation route onsite is inundated however the primary route onsite is passable and not expected to be affected.
13. Power was removed from siren 257 and 260 in Pottawattamie Co. IA, which is just on the edge of the 10-mile EPZ south east of the plant. Siren 75, 76 in Desoto National Wildlife Refuge have no power. Currently the refuge is closed due to flooding. Siren 1 east of Fort Calhoun on county road 34 between Fort Calhoun and Boyer Chute Recreational Area is without power.

This area is closed due to flooding. Power was removed to one additional siren in Washington County - sirens 69 was removed from service due to flooding and may require route alerting for any non-evacuated residents.

14. At this time no known major evacuation routes are affected without contingency actions planned. Interstate 29 in both directions: from Exit 54A (G Avenue) to Exit 71 (1-680 exit): 1-680 road closed to traffic because of flooding - follow the detour signs for the evacuation route to Bellevue. Interstate 680 in both directions: from before Exit 1 130th Street to Exit 62: 1-29; Old Mormon Bridge Road --- road closed because of flooding.

Requested Information from states and counties:

I. When offsite evacuation routes are affected please contact emergency planning.

2. When the Blair Water plant is affected please contact emergency planning.
3. Authorized power outages that affect or could affect siren operability, please contact I

emergency planning.

The river flow rate and level have been relatively constant at Blair NE. The Corp of Engineers is releasing Gavin's Point dam at 160,000 cubic feet per second (cfs).

Emergency Planning Contacts at FCS:

Steve Gebers:

Pager:j(b)(6)

Work Phone: 402-533-7308 Cell Phonefib)I(6)

Allen Berck:

Pager: 1(b)(6)

Work Phone: 402-636-2836 Cell:phone: 1(b)(6) 7 Allen' D. Berck I

Supelrvisor - Emergency Planning Fort Calhoun Station Oma.ha Public Power District phone: 402-533-6064 pageir: I(b)(6)]

i

,,2

eIrail: aberck@oDp!d.com This e-iicntains Omaha Pu *C Po er DiStrict's corf-ential d proprietary 1i ion and is f only by thei tende recipient. UnI s explicit stated otherse, this e-ail is not aontract o-er, ame dment, r

accep ce. If yo e not intended rec' nt e notified that g, copying, b

g or tak any ction in reliance on the contents of this information is strictly prohibited.

3