1 NRR-PMDAPEm Resource From:

Brown, Eva Sent:

Tuesday, December 20, 2011 12:53 PM To:

Thorpe, April

Subject:

FW: TS-474 CREVS LAR (TAC No. ME4668)

From: Lingam, Siva Sent: Thursday, July 28, 2011 9:23 AM To: Hess, Thomas A; tcmatthews@tva.gov Cc: Broaddus, Doug; Gratton, Christopher; Walker, Harold; Hamm, Matthew

Subject:

RE: TS-474 CREVS LAR (TAC No. ME4668)

In your supplement application with the proposed TS changes, the licensee should include a discussion containing an explanation and justification for the new/revised TS Conditions and each Required Action and associated Completion Time. We also expect clear discussion regarding the availability of airflow during replacement of HEPA filter bank and/or charcoal adsorbers.

From: Hess, Thomas A [1]

Sent: Wednesday, July 27, 2011 11:50 AM To: Lingam, Siva Cc: Matthews, Thomas C IV; Oliver, Michael W; Herrmann, Paul A III; Gratton, Christopher

Subject:

TS-474 CREVS LAR Based on 7/26/11 telecon, TVA proposes the following changes to BFN TS 3.7.3.

Condition C will be revised to cover a condition when both CREV subsystems are inoperable due to an inoperable HEPA filter. The associated Required Action C.1 will be revised to verify CREVS air flow is within the acceptable range with a completion time of immediately. The associated Required Action C.2 will be added to restore the HEPA Filter to OPERABLE status with a completion time of 7 days.

Condition D will be added to cover a condition when one or more CREV subsystems are inoperable due to an inoperable charcoal adsorber. The associated Required Action D.1 will be added to verify CREVS air flow is within the acceptable range with a completion time of immediately. The associated Required Action D.2 will be added to restore the charcoal adsorber to OPERABLE status with a completion time of 14 days.

The HEPA Filters and the charcoal adsorbers are not credited in any of BFNs Control Room Dose Analysis.

However, Control Room Envelop (CRE) airflow requirements have not changed. The proposed changes would provide additional Completion Time for conditions were the HEPA Filter or the charcoal adsorbers are inoperable for any condition which DOES NOT affect the CRE Air Flow requirements. Any condition associated with the HEPA Filter that DOES affect CRE Air Flow requirements will require the system to be declared inoperable and immediate entry into Condition E (currently condition C or condition D in the current LAR package). Any condition associated with the charcoal adsorbers that DOES affect CRE Air Flow requirements will require the subsystem to be declared inoperable under Condition A and the Condition A required actions and completion times would apply.

Tom Hess, P.E.

Program Manager TVA Corporate Nuclear Licensing Office: (423) 751-3487 Cell: (423) 619-2400 Email: tahess@tva.gov

2

Hearing Identifier:

NRR_PMDA Email Number:

221 Mail Envelope Properties (9B0F2FAB6002B64EAABF7FE5FA27BC6C508AB63171)

Subject:

FW: TS-474 CREVS LAR (TAC No. ME4668)

Sent Date:

12/20/2011 12:52:33 PM Received Date:

12/20/2011 12:52:35 PM From:

Brown, Eva Created By:

Eva.Brown@nrc.gov Recipients:

"Thorpe, April" <April.Thorpe@nrc.gov>

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 2859 12/20/2011 12:52:35 PM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: