ýýEn terg Entergy Nuclear Operations, Inc.
Nksj, ý St 1;i November 15, 2011 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555
SUBJECT:
Entergy Nuclear Operations, Inc.
Docket No.: 50-293 License No.: DPR-35
REFERENCE:
Pilgrim Fuel Cycle 19, Core Operating Limits Report, Revision 32
- 1. Entergy Letter No. 2.11.046, "10 CFR 50.46(a)(3)(ii) Report",
dated July 6, 2011 LETTER NUMBER:
2.11.066
Dear Sir or Madam:
The enclosed revision of Pilgrim Nuclear Power Station (Entergy) Core Operating Limits Report (COLR) is submitted in accordance with the requirements of Pilgrim's Technical Specification 5.6.5. COLR Revision 32 provides cycle-specific limits for operating Pilgrim during Cycle 19.
This mid-cycle COLR revision addresses Global Nuclear Fuel (GNF) LOCA Analytical Errors notified by GE Hitachi Letters 2011-02 and 2011-03, and restores the Peak Clad Temperature to below 2200'F for both GE14 and GNF2 fuels as required by 10 CFR 50.46 (Reference 1).
This letter completes the commitment made in Reference 1. This letter makes no new commitments.
Should you require further information concerning this submittal, please contact me at (508) 830-8403.
Sincerely, Joseph R LynchaI Licensing Manager
Enclosure:
PNPS Core Operating Limits Report, Revision 32 (51 pages) cc:
Regional Administrator, Region 1, U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector Pilgrim Nuclear Power Station Mr. Richard Guzman, Project Manager Plant Licensing Branch I-1 Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission One White Flint North, O-8C2 11555 Rockville Pike Rockville, MD 20852 cp I tsv' ---
ENCLOSURE TO ENTERGY LETTER NO 2.11.066, DATED NOVEMBER 9, 2011 PILGRIM NUCCLEAR POWER STATION CORE OPERATING LIMITS REPORT, REVISON 32 (51 Pages)
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 (CYCLE 19)
LBDCR2011-020 Documents Approvals Cycle 19 COLR Page 1 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 TABLE OF CONTENTS Page T IT L E & C O V E R P A G E 1...................
1 TABLE OF CONTENTS.....................................................................................................
2 RECORD OF REVISIONS....................................................................................................
3 L IS T O F T A B L E S.......................................................................................................................
4 L IS T O F F IG U R E S.....................................................................................................................
5
1.0 INTRODUCTION
6 1.1 Stability Option 1-D Exclusion Region and Buffer Zone.............................................
6 2.0 INSTRUMENTATION TRIP SETTINGS:.....................................................................
7 2.1 APRM Flux Scram Trip Setting (Run Mode).............................................................
7 2.2 APRM Rod Block Trip Setting (Run Mode)................................................................
12 2.3 Rod Block Monitor Trip Setting.................................................................................
12 3.0 CORE OPERATING LIMITS.....................................................................................
17 3.1 Maximum Average Planar Linear Heat Generation Rate (MAPLHGR).................... 17 3.2 Linear Heat Generation Rate (LHGR).....................................................................
37 3.3 Minimum Critical Power Ratio (MCPR)...................................................................
41 3.4 Power/Flow Relationship During Power Operation..................................................
46 4.0 REACTOR VESSEL CORE DESIGN........................................................................
49 5.0 R E F E R E N C E S..............................................................................................................
5 1 Cycle 19 COLR Revision 32 Page 2 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RECORD OF REVISIONS RTYPE: G4.02 Revision Effective Date 8A Effective date based on issuance of license amendment by NRC 9A Effective date based on issuance of license amendment by NRC for ARTS and SAFER/GESTR IOA Effective date based on initial startup of Cycle 10 11A Effective date based on initial startup of Cycle 11 11B Effective upon final approval 1 lC Effective upon final approval 11D Effective upon final approval 12A Effective date based on issuance of license amendment by NRC for SLMCPR of 1.08 12B Effective upon final approval 12C Effective upon final approval 12D Effective upon final approval 13A Effective upon final approval 14A Effective upon final approval 15A Effective upon final approval 15B Effective upon final approval 16A Effective upon final approval 16B Effective upon final approval 25 Effective upon final approval 26 Effective upon final approval 27 Effective upon final approval 28 Effective upon final approval 29 Effective upon final approval 30 Effective upon final approval 31 Effective upon final approval 32 Effective upon final approval Description Applicable for use during Cycle 8 Operation Applicable for use during Cycle 9 operation Applicable for use during Cycle 10 Operation Applicable for use during Cycle 11 Operation Applicable for use during Cycle 11 Operation Applicable for use during Cycle 11 Operation Applicable for use during Cycle 11 Operation Applicable for use during Cycle 12 Operation Renumbered Table 3.3-2 to 3.3-1, Sh. 2 of 2 and Table 3.3-1 to 3.3-1,Sh. 1 of 2 Changed Tech Spec section numbers referenced due to Tech Amendment #177.
Pages affected: 6, 24 Incorporated stability log-term solution option I-A.
Applicable for use during Cycle 13 Operation Applicable for use during Cycle 14 Operation Applicable for use during Cycle 15 Operation Changed MAPLHGR Limits for GE14 fuel in response to an input error GE corrected.
Applicable for use during Cycle 15 Operation Applicable for use during Cycle 16 Operation Core Loading Change to replace leaking fuel bundle JLG621. Clarified P-F Map graphic on P.
- 36. Applicable for use during Cycle 16 Operation Limits for Single Loop Operation were incorporated. Rev number scheme changed to Merlin Convention Applicable for use during Cycle 17 Operation Corrected typographical errors on p. 30, 34,38,39 per CR-PNP-2008-256 and 285 Extended Tables 3.1-1 to 63.5 GWD/ST (70 GWD/MT), updated Fig. 3.1-1, section 3.1 &
references, addressed CR-PNP-2009-01066 Applicable for use during Cycle 18 Operation Applicable for use during Cycle 19 Operation Corrected typographical error on fig.3.4-1 MAPLHGR limits were revised to correct errors reported by 2011-02 and 2011-03, CR-PNP-201 1-02556 Cycle 19 COLR Page 3 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 LIST OF TABLES Number 2.1-1 2.1-2 2.2-1 2.2-2 3.1-1 3.1-2 313-1 Title Formulae for APRM Flux Scram Trip Settings in Figure 2.1-1 Formulae for APRM Flux Scram Trip Settings in Figure 2.1-2 Formulae for APRM Rod Block Trip Settings in Figure 2.2-1 Formulae for APRM Rod Block Trip Settings in Figure 2.2-2 MAPLHGR Limits for Rated Power and Rated Flow for GE14 Fuel MAPLHGR Limits for Rated Power and Rated Flow for GNF2 Fuel MCPR Operating Limits At Rated Power and Rated Flow Pacie 8
9 13 14 18 25 42 Cycle 19 COLR Page 4 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT LIST OF FIGURES RTYPE: G4.02 Number 2.1-1 2.1-2 2.2-1 2.2-2 3.1-1 3.1-2 3.1-3 3.2-1 3.2-2 3.2-3 3.3-1 3.3-2 3.3-3 3.4-1 3.4-2 4.0-1 Title Allowable APRM Flux Scram Trip Settings - TLO Allowable APRM Flux Scram Trip Settings - SLO Allowable APRM Rod Block Trip Settings - TLO (Normal Feed water Temperature)
Allowable APRM Rod Block Trip Settings - SLO (Normal Feed water Temperature)
Most Limiting MAPLHGR Flow-Dependent MAPLHGR Factor (MAPFACF)
Power-Dependent MAPHLGR Factors Most Limiting LHGR for GE14 Fuel at Rated Power and Rated Core Flow Flow-Dependent LHGR Factor (LHGRFACF)
Power-Dependent LHGR Factors Flow-Dependent MCPR Limits (MCPRF)
Power-Dependent MCPR Limits (MCPRp), Turbine Bypass Assumed Operable and Normal and Reduced Feedwater Temperature Power-Dependent MCPR Limits (MCPRp), Turbine Bypass Assumed Out Of Service and Normal and Reduced Feedwater Temperature Power/Flow Operating Map, Scram and Rod Block Data Based on Allowable Values - TLO Power/Flow Operating Map, Scram and Rod Block Data Based on Allowable Values - SLO Reactor Vessel Core Loading Pattern Page 10 11 15 16 34 35 36 38 39 40 43 44 45 47 48 50 Cycle 19 COLR Page 5 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02
1.0 INTRODUCTION
This report provides the cycle-specific limits for operation of the Pilgrim Nuclear Power Station (PNPS) during Cycle 19. In this report, Cycle 19 will be referred to as the present cycle.
Although this report is not a part of the PNPS Technical Specifications, the Technical Specifications refer to this report for the applicable values of the following fuel-related parameters:
Reference Technical Specification APRM Flux Scram Trip Setting (Run Mode)
APRM Rod Block Trip Setting (Run Mode)
Rod Block Monitor Trip Setting Average Planar Linear Heat Generation Rate Linear Heat Generation Rate (LHGR)
Minimum Critical Power Ratio (MCPR)
Power/Flow Relationship Reactor Vessel Core Design Table 3,1.1 Table 3.2.C-2 Table 3.2.C-2 3.11.A 3.11.B 3.11.C 3.11.D 4.2 If any of the core operating limits in this report is exceeded, actions will be taken as defined in the referenced Technical Specification.
The core operating limits in this report have been established for the present cycle using the NRC-approved methodology provided in the documents listed in Technical Specification 5.6.5. These limits are established such that the applicable limits of the plant safety analysis are met.
1.1 Stability Option 1-D Exclusion Region and Buffer Zone.
The reactor shall not be intentionally operated within the Exclusion Region given in Figure 3.4-1, for Two Loop Operation (TLO) and Figure 3.4-2 for Single Loop Operation (SLO). Immediate exit is required for inadvertent entry into the exclusion region.
The reactor shall not be intentionally operated within the Buffer Zone given in Figure 3.4-1 for TLO and Figure 3.4-2, for SLO when the on-line Stability Monitor is inoperable.
Allowable values for APRM Scram and Rod Block trip set points are defined in Section 2.
Cycle 19 COLR Revision 32 Page 6 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 2.0 INSTRUMENTATION TRIP SETTINGS:
2.1 APRM Flux Scram Trip Setting (Run Mode)
Ref. Technical Specifications: Table 3.1.1 APRM flux scram Allowable Trip Set points (ATSP) for TLO are shown on Figure 2.1-1. The scram set point curve clamps power at 120% of rated core thermal power. Formulae used to develop Figure 2.1-1 are listed in Table 2.1-1.
APRM flux scram Allowable Trip Set points (ATSP) for SLO are shown on Figure 2.1-2, respectively. The scram set point curve clamps power at 120% of rated core thermal power.
Formulae used to develop Figure 2.1-2 are listed in Table 2.1-2.
In accordance with Technical Specification Table 3.1.1, Note 15, for no combination of loop recirculation flow rate and core thermal power shall the APRM flux scram trip setting be allowed to exceed 120% of rated thermal power. Flow clamp feature is not used in Cycle 19.
Drive Flow to Core Flow relationship:
APRM Trip settings use Drive flow to determine the power trip setting for both scrams and rod blocks, as the drive flow is a more reliable flow indication than core flow. The analysis calculates the stability based trip settings based on Core Flow.
Drive Flow (WD) normalization with core flow shall be done such that 100% Drive Flow with Two Loops corresponds to 100% Rated Core Flow of 69 M#/hr.
Source: Reference 5.6, sec. 2.1 Revision 32 Cycle 19 COLR Page 7 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 2.1-1 Formulae For Allowable APRM Flux Scram Settings In Figure 2.1-1 Two Loop Operation Allowable Trip Set Point Drive Flow Range (ATSP)
C D
C D
% Rated SLOPE INTERCEPT 0.20 71.5 0 < WD < 22.5 0.71 60.0 22.5 < WD !5 55.9 0.65 70.6 55.9 < WD <- 76 0
120.0 76 < WD 5 125 Notes:
1.
2.
3.
ATSP = C * % Wo + D, ATSP is in % Power Figure 2.1-1 shows the plot of ATSP vs. WD.
Reference 5.6, Table 1.a is the basis for the values of constants listed in this Table.
Cycle 19 COLR Page 8 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 2.1-2 Formulae For Allowable APRM Flux Scram Settings In Figure 2.1-2 Single Loop Operation Allowable Trip Set Point Drive Flow Range (ATSP)
C D
C D
% Rated SLOPE INTERCEPT 0.20 69.5 0 < Wo -< 32.5 0.71 52.9 32.5 < WD !5 65.9 0.65 64.1 65.9 < W0 < 86 0
120.0 86 < WD 5 125 Notes:
1.
2.
3.
ATSP = C * % W( + D, ATSP is in % Power Figure 2.1-2 shows the plot of ATSP vs. WD.
Reference 5.6, Table 1.b is the basis the values of constants listed in this Table.
Revision 32 Cycle 19 COLR Page 9 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 2.1-1 Allowable APRM Flux Scram Trip Settings - TLO (Normal Feedwater Temperature) 130.0 I
120.0~t
.t.
.. _j
! /,,
t a ~ i.
.1.
7......
01100 e40007 0
110....9 10.0 -
Ui I
9 0.0
-i 76-
- a.
70.0 F"
I.
60.0 0
10 20 30 40 50 60 70 80 90 100 110 120 WD, Drive Flow, %
Revision 32 Cycle 19 COLR Page 10 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 2.1-2 Allowable APRM Flux Scram Trip Settings - SLO (Normal Feedwater Temperature) 130.0 120.0 0.110.0 100.0 90.0 0
80.0
- a. 70.0 60.0 120
.0.
69.5
......i I
90 1
i 80 90 100 110 120
.i..
...i......
-i.....
0 10 20 30 40 50 60 70 WE, Drive Flow, %
Revision 32 Cycle 19 COLR Page 11 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 2.2 APRM Rod Block Trip Setting (Run Mode)
Reference Technical Specifications: Table 3.2.C-2, 3.1.B.1 When the mode switch is in the RUN position, the Average Power Range Monitor (APRM) rod block Allowable Trip setting (ATSPRB) as a function of drive flow for Two Loop Operation shall be as given by Figure 2.2-1.
The ATSPRB is clamped at 115% of rated core thermal power. Formulae that form the basis of the Figure 2.2-1 are listed in Table 2.2-1. The flow clamp feature is not used in Cycle 19.
When the mode switch is in the RUN position, the Average Power Range Monitor (APRM) rod block Allowable Trip setting (ATSPRB) as a function of drive flow for Single Loop Operation shall be as given by Figure 2.2-2. The ATSPRB is clamped at 115% of rated core thermal power. Formulae that form the basis of the Figures 2.2-2 are listed in Table 2.2-2. The flow clamp feature is not used in Cycle 19.
2.3 Rod Block Monitor Trip Setting
References:
Technical Specification Table 3.2.C-2, Ref. 5.15, Ref. 5.10 Table 4.5 (b)
Allowable values for the power-dependent Rod Block Monitor trip set points shall be:
Reactor Power, P Trip Set point (Allowable Value)
(% of Rated)
(% of Reference Level)
P _< 25.9 Not applicable (All RBM Trips Bypassed) 25.9 < P _ 62.0 122 62.0 < P _ 82.0 118 82.0 < P 113 The allowable value for the RBM downscale trip set point shall be _< 94.0% of the reference level. The RBM downscale trip is bypassed for reactor power _< 25.9% of rated (Technical Specification Table 3.2.C-1, Note 5). Analytical Value of Rod Block set point of 117% is justified as the Rod Withdrawal Error is expected to reduce MCPR by 0.28 if this set point is used. Since the minimum OLMCPR value is 1.49, a reduction of 0.28 in MCPR, starting with operation at OLMCPR, is expected to lower MCPR to 1.21. This is substantially above the Safety Limit MCPR of 1.08. Allowable value of the HTSP is set at 113 % to provide additional conservatism tb account for uncertainties. Table 4-5(b) of Reference 5.10 with a more restrictive OLMCPR of 1.35 was used to determine the RBM set points with margin.
Cycle 19 COLR Revision 32 Page 12 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 2.2-1 Formulae For Allowable APRM Rod Block Settings In Figure 2.2-1 Two Loop Operation APRM Rod Block Allowable Trip Set Drive Flow Range Point (ATSPRB)
C D
C D
O%
Rated SLOPE INTERCEPT 0.20 66.5 0 < WD 5 22.5 0.71 55.0 22.5 < WD < 55.9 0.65 63.6 55.9 < WD < 79.1 0
115.0 79.1 < WD < 125 Notes:
- 1. ATSPRB = C * % WD + D, ATSPRB is in % Power
- 2. Figure 2.2-1 shows the plot of ATSPRB VS. WD.
- 3. Reference 5.6, Table 1.a is the basis for the values of constants listed in this Table.
Revision 32 Cycle 19 COLR Page 13 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 2.2-2 Formulae For Allowable APRM Rod Block Settings In Figure 2.2-2 Single Loop Operation APRM Rod Block Allowable Trip Set Drive Flow Range Point (ATSPRB)
C D
C D
% Rated SLOPE INTERCEPT 0.20 64.5 0 -< WD < 32.5 0.71 47.9 32.5 < WD < 65.9 0.65 57.1 65.9 < WD < 89.1 0
115.0 89.1 < WD < 125 Notes:
- 1. ATSPRB= C *% WD + D, ATSPRB is in % Power
- 2. Figure 2.2-2 shows the plot of ATSPRB vs. WD.
- 3. Reference 5.6, Table 1.b is the basis for the values of constants listed in this Table.
Cycle 19 COLR Page 14 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 2.2-1 Allowable APRM Flux Rod Block Trip Settings -TLO (Normal Feedwater Temperature) 120.0
.- 110.0 90.0 0
0 80.0 7 90.0 60.0 0
10 20 30 40 50 60 70 80 90 100 110 120 WD, Drive Flow, %
Revision 32 Cycle 19 COLR Page 15 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 2.2-2 Allowable APRM Flux Rod Block Trip Settings - SLO (Normal Feedwater Temperature) 120.0 0.
7i 0
10 20 30 40 50 60 70 80 90 100 110 120 WD, Drive Flow, %
Cycle 19 COLR Page 16 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 3.0 CORE OPERATING LIMITS 3.1 Maximum Average Planar Linear Heat Generation Rate (MAPLHGR)
Reference Technical Specification: 3.1 1.A During power operation, MAPLHGR for each fuel type as a function of axial location and average planar exposure shall not exceed the applicable limiting value. The applicable limiting value for each fuel type is the smaller of the flow-dependent and power-dependent MAPLHGR limits, MAPLHGRF and MAPLHGRp. The flow-dependent MAPLHGR limit, MAPLHGRF, is the product of the MAPLHGR flow factor, MAPFACF, shown in Figure 3.1-2 and the MAPLHGR for rated power and flow conditions, given in Tables 3.1-1 and 3.1-2 for GE14 and GNF2, respectively. The power-dependent MAPLHGR limit, MAPLHGRp, is the product of the MAPLHGR power factor, MAPFACp in Figure 3.1-3 and the MAPLHGR limit for rated power and flow conditions, given in Tables 3.1-1 and 3.1-2.
MAPLHGR for rated power and flow conditions for the most limiting lattice in each fuel type (excluding natural uranium lattices) are presented in Figure 3.1-1.
MAPLHGR limits are based on ECCS-LOCA considerations. For each lattice type, the MAPLHGR values for rated power and flow conditions are listed in Tables 3.1-1 and 3.1-2, which are obtained from the Supplemental Reload Licensing Report, Revi (Ref. 5.15).
SRLR, Rev. 1 corrected MAPLHGR tables for LOCA analytical error reports 2011-02 and 2011-03 to restore the Peak Clad Temperature to 2150 'F for both GE14 for > 23 GWD/MT exposure and GNF2 fuels for all exposures. For GE14 fuel with less than 23 GWD/MT exposure the Peak Clad Temperature is calculated to be less than 2200 "F.
Pbyoass is the power level below which more restrictive thermal limits are applied, as the Turbine Stop Valve closure and Turbine Control Valve fast closure scrams are assumed to be bypassed. It can be set anywhere in the range from 32.5% power to 45% power. Pbypass is currently set at 32.5% power. If this setting is changed in the future, then the appropriate thermal limits can be determined using Tables 3.1-1 and 3.1-2 with Figure 3.1-3.
When in Single Loop Operation, an SLO Multiplier of 0.8 for GE14 fuel and 0.89 for GNF2 fuel applies to the Rated MAPLHGR limit. At off rated conditions, MAPLHGR limit is the lower of the SLO Multiplier times the rated MAPLHGR limit, the MAPLHGRP or MAPLHGRF.
Per the GNF letter in Reference 5.22, the dashes on the MAPLHGR Tables in the SRLR indicate that no specific calculation of MAPLHGR limit was done at that point.
Additionally, the limit value given for last exposure state point listed is applicable for higher exposures up to 63.5 GWD/ST (70 GWD/MT). This is consistent with LOCA analysis reports (References 5.3 and 5.21). As in previous cycle, 3D monicore is designed to apply the MAPLHGR limits consistent with this explanation.
Cycle 19 COLR Revision 32 Page 17 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-1 MAPLHGR Limits for Rated Power and Rated Flow for GE14 Fuel Average Bundle Type: GE14-PI0DNAB399-10G6.0/3G5.0/1G2.0-10OT-145-T6-2828 (GE14C)
Planar Exposure MAPLHGR Limit (kW/ft)
Lattice Lattice Lattice Lattice Lattice Lattice GWdIMT GWd/ST 6843 6844 6845 6846 6847 6848 0.00 0.00 9.80 8.79 8.76 8.74 10.21 10.89 0.22 0.20 9.71 8.86 8.84 8.82 10,16 10.86 1.10 1.00 9.50 8.96 8.96 8.95 10.01 10.78 2.20 2.00 9.44 9.10 9.13 9.12 9.98 10.77 3.31 3.00 9.45 9.23 9.31 9.31 10.01 10.80 4.41 4.00 9.49 9.31 9.50 9.50 10.05 10.84 5.51 5.00 9.53 9.40 9.60 9.64 10.10 10.89 6.61 6.00 9.57 9.48 9.70 9.74 10.15 10.92 7.72 7.00 9.61 9.57 9.79 9.84 10.18 10.95 8.82 8.00 9.64 9.65 9.89 9.94 10.21 10.97 9.92 9.00 9.66 9.74 9.98 10.03 10.24 10.99 11.02 1 0.00 9.68 9.82 10.07 10.12 10.25 11.00 12.13 11.00 9.69 9,91 10.17 10.22 10.27 11.01 13.23 12.00 9.67 9.97 10.26 10.32 10.27 1 1.01 14.33 13.00 9.64 10.02 10.34 10.40 10.24 11.0 L 15.43 14.00 9.60 10.08 10.40 10.47 10.20 10.97 15.99 14.51 9.58 10.11 10.43 10.49 10.18 10.95 16.53 15.00 9.56 10.14 10.45 10.51 10.16 10.93 18.74 17.00 9.48 10.21 10.50 10.56 10.07 10.84 22.05 20.00 9.35 10.27 10.54 10.59 9.94 10.71 23.01 20.87 9.28 10.27 10.55 10.60 9.89 10.68 27.56 25.00 8.95 10.25 10.58 10.63 9.66 10.51 32.19 29.20 8.40 9.94 10.26 10.32 9.11 10.05 33.07 30.00 8.30 9.88 10.20 10.26 9.01 9.97 38.58 35.00 7.65 9.48 9.72 9.72 8.37 9.33 44.09 40.00 7.02 9.03 9.19 9.20 7.73 8.69 49.60 45.00 6.38 8.51 8.66 8.67 7.10 8.06 54.79 49.71 3.98 55.12 50.00 7.94 8.12 8.13 5.64 7.43 58.16 52.77 4.21 60.63 55.00 5.83 6.65 6.82 5.50 62.70 56.88 4.87 62.74 56.91 4.52 63.50 57.6 t 5.32 5.49 64.36 58.38 4.92 64.70 58.69 4.94 70.00..
63.50 3.98 4.87 4.92 4.94 4.21 4.52 Cycle 19 COLR Page 18 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-1 MAPLHGR Limits for Rated Power and Rated Flow for GEl4 Fuel (cont.)
Average Planar Bundle Type: GEI4-P1ODNAB398-8G6.0/5G5.O/2G4.0-10OT-145-T6-2829 Exposure (GE14C)
MAPLHGR Limit (kW/ft)
GWd/MT GWd/ST Lattice Lattice Lattice Lattice Lattice Lattice 6849 6850 6851 6852 6853 6854 0.00 0.00 9.80 8.69 8.67 8.63 10.21 10.94 0.22 0.20 9.71 8.75 8.74 8.71 10.16 10.92 1.10 1.00 9.50, 8.86 8.86 8.83 10.01 10.84 2.20 2.00 9.44 9.00 9,04 9.01 9.98 10.83 3.31 3.00 9.45 9.08 9.21 9.19 10.01 10.86 4.41 4.00 9.49 9.17 9.33 9.36 10.05 10.90 5.51 5.00 9.53 9.25 9.42 9.45 10.10 10.93 6.61 6.00 9.57 9.34 9.51 9.55 10.15 10.96 7.72 7.00 9.61 9.43 9.61 9.64 10.18 10.99 8.82 8.00 9.64 9.51 9.71 9.74 10.21 11.01 9.92 9.00 9.66 9.60 9.82 9.86 10.24 11.03 11.02 10.00 9.68 9.70 9.94 9.99 10.25 11.04 12.13 11.00 9.69 9.81 10.08 10.13 10.27 11.05 13.23 12.00 9.67 9.89 10.19 10.25 10.27 11.05 14.33 13.00 9.64 9.96 10.28 10.35 10.24 11.05 15.43 14.00 9.60 10.04 10.36 10.43 10.20 11.02 15.99 14.51 9.58 10.07 1
10.39 10.46 10.18
.11.00 16.53 15.00 9.56 10.10 10.42 10.49 10.16 10.97 18.74 17.00 9.48 10.19 10.49 10.55 10.07 10.89 22.05 20.00 9.35 10.27 10.54 10.59 9.94 10.76 23.01 20.87 9.28 10.26 10,55 10.59 9,89 10.72 27.56 25.00 8.95 10.24 10.56 10.62 9.66 10.55 32.19 29.20 8.40 9.93 10.26 10.30 9.11 10.11 33.07 30.00 8.30 9.87 10.20 10.24 9.01 10.02 38.58 35.00 7.65 9.47 9.71 9.71 8.37 9.38 44.09 40.00 7.02 9.02 9.18 9.19 7.73 8.75 49.60 45.00 6.38 8.51 8.65 8.66 7.10 8.12 54.79 49.71 3.98 55.12 50.00 7.93 8.11 8.13 5.64 7.49 58.16 52.77 4.21 60.63 55.00 5.75 6.57 6.75 5.64 62.52 56.72 4.88 63.01 57.16 4.54 63.50 57.61 5.24 5.41 64.17 58.22 4.93 64.51 58.52 4.95 70.00 63.50 3,98 4.88 4.93 4.95 4.21 4,54 Cycle 19 COLR Page 19 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-1 MAPLHGR Limits for Rated Power and Rated Flow for GE14 Fuel (cont.)
Average Bundle Type: GE14-PIODNAB399-15GZ-1OOT-145-T6-2957 (GE14C)
Planar Exposure MAPLHGR Limit (kW/ft)
Lattice Lattice Lattice Lattice Lattice Lattice GWd/MT GWd/ST 7492 7493 7494 7495 7496 7497 0.00 0.00 9.80 8.73 8.56 8.54 10.21 10.97 0.22 0.20 9.71 8.80 8.65 8.63 10.16 10.94 1.10 1.00 9.50 8.91 8.78 8.77 10.01 10.86 2.20 2.00 9.44 9.05 8.97 8.95 9.98 10.85 3.31 3.00 9.45 9.21 9.16 9.15 10.01 10.87 4.41 4.00 9.49 9.35 9.37 9.37 10.05 10.90 5.51 5.00 9.53 9.48 9.59 9.59 10.10 10.94 6.61 6.00 9.57 9.62 9.81 9.78 10.15 10.97 7.72 7.00 9.61 9.73 9.94 9.89 10.18 11.00 8.82 8.00 9.64 9.84 10.05 10.02 10.21 11.02 9.92 9.00 9.66 9.96 10.17 10.15 10.24 11.04 11.02 10.00 9.68 10.08 10.30 10.30 10.25 11.05 12.13 11.00 9.69 10.20 10.44 10.45 10.27 11.06 13.23 12.00 9.67 10.30 10.56 10.58 10.27 11.06 14.33 13.00 9.64 10.37 10.64 10.66 10.24 11.06 15.43 14.00 9.60 10.43 10.70 10.72 10.20 11.02 15.99 14.51 9.58 10.45 10.72 10.74 10.18 11.00 16.53 15.00 9.56 10.48 10.74 10.76 10.16 10.98 18.74 17.00 9.48 10.53 10.79 10.80 10.07 10.90 22.05 20.00 9.35 10.57 10.81 10.78 9.94 10.77 23.01 20.87 9.28 10.57 10.80 10.75 9.89 10.73 27.56 25.00 8.95 10.56 10.72 10.66 9.66 10.56 32.19 29.20 8.40 10.19 10.35 10.33 9.11 10.12 33.07 30.00 8.30 10.12 10.28 10.27 9.01 10.03 38.58 35.00 7.65 9.62 9.73 9.73 8.37 9.39 44.09 40.00 7.02 9.09 9.20 9.21 7.73 8.76 49.60 45.00 6.38 8.55 8.67 8.68 7.10 8.13 54.79 49.71 3.98 55.12 50.00 8.00 8.12 8.14 5.64 7.50 58.16 52.77 4.21 60.63 55.00 6.34 6.90 6.89 5.67 63.05 57.20 4.54 63.50 57.61 5.02 5.60 5.59 63.77 57.85 4,89 65.06 59.02 4.89 65.11 59.06 4.88 70.00 63.50 3.98 4.89 4.88 4.89 4,21 4.54 Cycle 19 COLR Page 20 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-1 MAPLHGR Limits for Rated Power and Rated Flow for GE14 Fuel (cont.)
Average Planar Bundle Type: GE14-PIODNAB398-5G6.0/10G5.0-1OOT-145-T6-2958 (GE14C)
Exposure MAPLHGR Limit kW/ft Lattice Lattice Lattice Lattice Lattice Lattice GWd/MT GWdtST 7492 7498 7499 7500 7501 7502 0.00 0.00 9.80 8.73 8.69 8.66 10.21 10.97 0.22 0.20 9.71 8.80 8.76 8.74 10,16 10.94 1,10 1.00 9.50 8.91 8.89 8.87 10.01 10.86 2.20 2.00 9.44 9.06 9.07 9.06 9.98 10.85 3.31 3.00 9.45 9.21 9.26 9.25 10.01 10.87 4.41 4.00 9.49 9.34 9.46 9.44 10.05 10.90 5.51 5.00 9.53 9,47 9.62 9.56 10.10 10.94 6.61 6.00 9.57 9.61 9.74 9.69 10.15 10.97 7.72 7.00 9.61 9.72 9.86 9.82 10.18 11.00 8.82 8.00 9.64 9.83 9.99 9.96 10.21 11.02 9.92 9.00 9.66 9.94 10.13 10.11 10.24 11.04 11.02 10.00 9.68 10.06 10.28 10.28 10.25 11.05 12,13 11.00 9.69 10.18 10.43 10.44 10.27 11.06 13,23 12.00 9.67 10.28 10.56 10.58 10.27 11.06 14.33 13.00 9.64 10.36 10.65 10.67 10.24 11.06 15.43 14.00 9.60 10.42 10.71 10.73 10.20 11.02 15.99 14.51 9.58 10.45 10.73 10.75 10.18 11.00 16.53 15.00 9.56 10.47 10.75 10.77 10.16 10.98 18.74 17.00 9.48 10.53 10.80 10.81 10.07 10.90 22.05 20.00 9.35 10.57 10.82 10.78 9.94 10.77 23.01 20.87 9.28 10.57 10.80 10.76 9.89 10.73 27.56 25.00 8.95 10.55 10.73 10.66 9.66 10.56 32.19 29.20 8.40 10.19 10.34 10,33 9.11 10.12 33.07 30.00 8.30 10.12 10.27 10.26 9.01 10.03 38.58 35.00 7.65 9.62 9.73 9.73 8.37 9.39 44.09 40.00 7.02 9.08 9.19 9.20 7.73 8.76 49.60 45.00 6.38 8.55 8.66 8.67 7.10 8.13 54.79 49.71 3.98 55.12 50.00 8.00 8.12 8.13 5.64 7.50 58.16 52.77 4.21 60.63 55.00 6.32 6.86 6.85 5.67 63.05 57.20 4,54 63.50 57.61 5.00 5.56 5.55 63.75 57.83 4.89 64.96 58.93 4,89 65.01 58.98 4.88 70.00 63.50 3.98 4.89 4.88 4.89 4.21 4.54 Revision 32 Cycle 19 COLR Page 21 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-1 MAPLHGR Limits for Rated Power and Rated Flow for GE14 Fuel (cont.)
Average Bundle Type: GE14-PIODNAB400-13GZ-100T-145-T6-2959 Planar (GE14C)
Exposure MAPLHGR Limit (kW/ft)
Lattice Lattice Lattice Lattice Lattice Lattice GWd/MT GWd/ST 7492 7503 7504 7505 7506 7507 0.00 0.00 9.80 8.88 8.88 8.86 10.21 10.81 0.22 0.20 9.71 8.94 8.95 8.94 10.16 10.78 1.10 1.00 9.50 9.03 9.06 9.05 10.01 10.69 2.20 2.00 9.44 9.17 9.23 9.22 9.98 10.69 3.31 3.00 9.45 9.30 9.40 9.39 10.01 10.72 4.41 4.00 9.49 9.42 9.58 9.58 10.05 10.76 5.51 5.00 9.53 9.54 9.74 9.71 10.10 10.80 6.61 6.00 9,57 9.66 9.88 9.82 10.15 10.84 7.72 7.00 9.61 9.78 9.98 9.94 10.18 10.88 8.82 8.00 9.64 9.90 10.10 10.06 10.21 10.90 9.92 9.00 9.66 10.00 10.22 10.20 10.24 10.92 11.02 10.00 9.68 10.10 10.35 10.34 10.25 10.94 12.13 1t.00 9.69 10.20 10.49 10.49 10.27 t0.95 13.23 12.00 9.67 10.30 10.61 10.63 10.27 10.95 14.33 13.00 9.64 10.37 10.70 10.72 10.24 10.95 15.43 14.00 9.60 10.44 10.76 10.78 10.20 10.91 15.99 14.51 9.58 10.47 10.78 10.80 10.18 10.89 16.53 15.00 9.56 10.50 10.80 10.81 10.16 10.87 18.74 17.00 9.48 10.56 10.82 10.83 10.07 10.78 22.05 20.00 9.35 10.58 10.82 10.78 9.94 10.65 23.01 20.87 9.28 10.58 10.80 10.75 9.89 10.61 27.56 25.00 8.95 10.56 10.72 10.62 9.66 10.44 32.19 29.20 8.40 10.20 10.36 10.33 9.11 9.97 33.07 30.00 8.30 10.13 10.29 10.28 9.01 9.89 38.58 35.00 7.65 9.63 9.74 9.74 8.37 9.25 44.09 40.00 7.02 9.10 9.21 9.22 7.73 8.61 49.60 45.00 6.38 8.56 8.68 8.69 7.10 7.98 54.79 49.71 3.98 55.12 50.00 8.01 8.14 8.15 5.64 7.35 58.16 52.77 4.21 60.63 55.00 6.39 6.97 6.96 5.29 62.34 56.55 4.49 63.50 57.61 5,07 5.67 5.66 63.89 57.96 4.89 65.20 59.15 4.89 65.25 59.19 4.88 70.00 63.50 3.98 4.89 4.88 4.89 4.21 4.49 Revision 32 Cycle 19 COLR Page 22 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-1 MAPLHGR Limits for Rated Power and Rated Flow for GE14 Fuel (cont.)
Average Bundle Type: GE14-P1ODNAB404-5G6.0/10G5.0-1OOT-145-T6-2960 (GE14C)
Planar Exposure MAPLHGR Limit
_kWlft)
Lattice Lattice Lattice Lattice Lattice Lattice GWd/MT GWdlST 7492 7508 7509 7510 7511 7512 0
0 9.8 8.76 8.72 8.7 10.21 10.97 0.22 0.2 9.71 8.83 8.8 8,78 10.16 10.94 1.1 1
9.5 8.94 8.93 8.91 10.01 10.86 2.2 2
9.44 9.09 9.11 9.1 9.98 10.85 3.31 3
9.45 9.24 9.3 9.29 10.01 10.87 4.41 4
9.49 9.38 9.5 9.48 10.05 10.9 5.51 5
9.53 9.51 9.66 9.6 10.1 10.94 6.61 6
9.57 9.64 9.78 9.73 10.15 10.97 7.72 7
9.61 9.75 9.9 9.86 10.18 11 8.82 8
9.64 9.86 10.03 10 10.21 11.02 9.92 9
9.66 9.97 10.16 10.15 10.24 11.04 11.02 10 9.68 10.08 10.31 10.31 10.25 11.05 12.13 11 9.69 10.2 10.46 10.47 10.27 11.06 13.23 12 9.67 10.31 10.59 10.61 10.27 11.06 14.33 13 9.64 10.38 10.68 10.7 10.24 11.06 15.43 14 9.6 10.45 10.75 10.77 10.2 11.02 15.99 14.51 9.58 10.47 10.77 10.79 10.18 11 16.53 15 9.56 10.5 10.79 10.81 10.16 10.98 18.74 17 9.48 10.56 10.85 10.86 10.07 10.9 22.05 20 9.35 10.61 10.87 10.85 9.94 10.77 23.01 20.87 9.28 10.61 10.84 10.82 9.89 10.73 27.56 25 8.95 10.6 10.7 10.67 9.66 10.56 32.19 29.2 8.40 10.24 10.42 10.41 9.11 10.12 33.07 30 8.3 10.17 10.36 10.36 9.01 10.03 38.58 35 7.65 9.69 9.81 9.77 8.37 9.39 44.09 40 7.02 9.15 9.23 9.17 7.73 8.76 49.6 45 6.38 8.61 8.65 8.6 7.1 8.13 54.79 49.71 3.98 55.12 50 8.06 8.11 8.06 5.64 7.5 58.16 52.77 4.21 60.63 55 6.46 7.08 7.07 5.67 63.05 57.2 4.54 63.5 57.61 5.14 5.78 5.77 64.01 58.07 4.91 65.41 59.34 4.91 65.45 59.37 4.9 70.00 63.50 3.98 4.91 4.90 4.91 4.21 4.54 Revision 32 Cycle 19 COLR Page 23 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-1 MAPLHGR Limits for Rated Power and Rated Flow for GEl4 Fuel (cont.)
Average Planar Bundle Type: GE14-P1ODNAB400-12G6.0/3GS.0-10OT-145-T6-2961 (GE14C)
Exposure MAPLHGR Limit (kW/ft)
Lattice Lattice Lattice Lattice Lattice Lattice GWd/MT GWd/ST 7492 7513 7514 7515 7516 7517 0.00 0.00 9.80 8.71 8.67 8.65 10.21 10.97 0.22 0.20 9.71 8.78 8.74 8.72 10.16 10.94 L.10 1.00 9.50 8.88 8.86 8.84 10.01 10.86 2.20 2.00 9.44 9.02 9.03 9.01 9.98 10.85 3.31 3.00 9.45 9.16 9.20 9.19 10.01 10.87 4.41 4.00 9.49 9.31 9.39 9.38 10.05 10.90 5.51 5.00 9.53 9.43 9.58 9.52 10.10 10.94 6.61 6.00 9.57 9.56 9.70 9.64 10.15 10.97 7.72 7.00 9.61 9.67 9.81 9.76 10.18 11.00 8.82 8.00 9.64 9.78 9.93 9.89 10.21 11.02 9.92 9.00 9.66 9.88 10.05 10.03 10.24 11.04 11.02 10.00 9.68 9.99 10.19 10.18 10.25 11.05 12.13 11.00 9.69 10.11 10.34 10.34 10.27 11.06 13.23 12.00 9.67
[0.21 10.47 10.48
[0.27 1 1.06 14.33 13.00 9.64 10.29 10.57 10.59 10.24 11.06 15.43 14.00 9.60 10.37 10.66 10.68 10.20 11.02 15.99 14.51 9.58 10.40 10.69 10.72 10.18 11.00 16.53 15.00 9.56 10.43 10.73 10.75 10.16 10.98 18.74 17.00 9.48 10.52 10.81 10.83 10.07 10.90 22.05 20.00 9.35 10.59 10.84 10.80 9.94 10.77 23.01 20.87 9.28 10.59 10.82 10.77 9.89 10.73 27.56 25.00 8.95 10.57 10.73 10.64 9.66 10.56 32.19 29.20 8.40 10.21 10.35 10.33 9.11 10.12 33.07 30.00 8.30 10.14 10.28 10.27 9.01 10.03 38.58 35.00 7.65 9.63 9.74 9.74 8.37 9.39 44.09 40.00 7.02 9.09 9.21 9.21 7.73 8.76 49.60 45.00 6.38 8.56 8.67 8.68 7.10 8.13 54.79 49.71 3.98 55.12 50.00 8.01 8.13 8.14 5.64 7.50 58.16 52.77 4.21 60.63 55.00 6.35 6.92 6.91 5.67 63.05 57.20 4.54 63.50 57.61 5.03 5.62 5.61 63.79 57.87 4.90 65.09 59.05 4.89 65.15 59.10 4.88 70.00 63.50 3.98 4.90 4.88 4.89 4.21 4.54 Cycle 19 COLR Page 24 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-2 MAPLHGR Limits for Rated Power and Rated Flow for GNF2 Fuel Average Bundle Type: GNF2-P10DG2B389-6G6.0/8G5.0-100T2-145-T6-3141 Planar (GNF2)
Exposure MAPLHGR Limit (kWIft_
Lat.
Lattice Lattice Lattice Lattice Lattice Lat.
GWdlMT GWd/ST 8661 8668 8669 8670 8671 8672 8667 0
0 9.53 9.02 9.15 9.27 8.75 8.46 10.2 0.22 0.2 9.44 9.04 9.19 9.31 8.78 8.49 10.14 1.1 1
9.23 9.11 9.27 9.39 8.86 8.58 9.98 2.2 2
9.16 9.2 9.37 9.49 8.98 8.71 9.92 3.31 3
9.17 9.3 9.47 9.6 9.1 8.84 9.93 4.41 4
9.2 9.39 9.58 9.71 9.23 8.98 9.95 5.51 5
9.24 9.5 9.68 9.8.1 9.36 9.12 9.98 6.61 6
9.27 9.6 9.79 9.92 9.49 9.27 10.01 7.72 7
9.31 9.7 9.89 10.03 9.62 9.41 10.03 8.82 8
9.33 9.8 10 10.13 9.76 9.56 10.05 9.92 9
9.36 9.9 10.12 10.13 9.9 9.71 10.07 11.02 10 9.37 10 10.23 10.14 10.05 9.86 10.08 12.13 11 9.35 10.09 10.34 10.17 9.95 9.96 10.08 13.23 12 9.31 10.13 10.41 9.99 9.85 9.92 10.04 14.33 13 9.26 10.17 10.35 9.93 9.84 9.91 9.99 15.43 14 9.21 10.21 10.27 9.9 9.82 9.88 9.94 16.53 15 9.16 10.23 10.18 9.87 9.8 9.86 9.88 17,64 16 9.11 10.25 10.1 9.85 9.77 9,82 9.83 18.74 17 9.06 10.21 10.03 9.81 9.73 9.78 9.77 19.84 18 9
10.14 9.98 9.77 9.69 9.74 9.72 20.94 19 8.95 10.09 9.92 9.72 9.64 9.69 9.66 22.05 20 8.9 10.03 9.87 9.68 9.6 9.64 9.6 23.15 21 8.84 9.97 9.81 9.63 9.55 9.59 9.55 24.25 22 8.79 9.91 9.76 9.59 9.51 9.55 9.49 25.35 23 8.73 9.86 9.7 9.54 9.47 9.5 9.44 26.46 24 8.68 9.8 9.65 9.5 9.42 9.46 9.38 27.56 25 8.62 9.74 9.59 9.45 9.38 9.41 9.33 33.07 30 8.23 9.46 9.33 9.23 9.19 9.2 9.06 38.58 35 7.42 9.21 9.09 9.01 8.98 8.99 8.37 40.85 37.06 7.08 9.03 8.91 8.81 8.78 8.79 8.04 44.09 40 6.61 8.77 8.66 8.52 8.49 8.51 7.57 49.6 45 5.81 8.07 8.01 7.9 7.89 7.91 6.77 54.42 49.37 4.26 55.12 50 7.36 7.38 7.28 7,29 7.18 5.97 58.61 53.17 4.55 60.63 55 6,6 6.76 6.54 6.41 6,04 62.31 56.52 5.28 63.14 57.28 5.28 63.44 57.55 5.33 63.47 57.58 5.26 64.63 58.63 5.27 70.00 63.50 4.26 5.33 5.27 5.26 5.28 5.28 4.55 Cycle 19 COLR Page 25 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-2 MAPLHGR Limits for Rated Power and Rated Flow for GNF2 Fuel (cont.)
Average Planar Bundle Type: GNF2-PI0DG2B389-6G6.012G5.016G4.0-100T2-145-T6-3142 (GNF2)
Exposure MAPLHGR Limit (kW/ft)
GWd/MT GWd/ST Lat.
Lat.
Lat.
Lat.
Lat.
Lat.
Lat.
8661 8662 8663 8664 8665 8666 8667 0.00 0.00 9.53 9.00 9.18 9.31 8.78 8.49 10.20 0.22 0.20 9.44 9.02 9.20 9.34 8.82 8.53 10.14 1.10 1.00 9.23 9.08 9.28 9.42 8.91 8.63 9.98 2.20 2.00 9.16 9.17 9.38 9.53 9.04 8.76 9.92 3.31 3.00 9.17 9.27 9.49 9.64 9.17 8.90 9.93 4.41 4.00 9.20 9.36 9.60 9.76 9,31 9.03 9.95 5.51 5.00 9.24 9.46 9.72 9.88 9.45 9.17 9.98 6.61 6.00 9.27 9.56 9.84 10.01 9.59 9.32 10.01 7.72 7.00 9.31 9.67 9.96 10.13 9.74 9.47 10.03 8.82 8.00 9.33 9.78 10.09 10.24 9.90 9.63 10.05 9.92 9.00 9.36 9.89 10.23 10.25 10.05 9.79 10.07 11.02 10.00 9.37 10.01 10.35 10.26 10.19 9.94 10.08 12.13 11.00 9.35 10.11 10.46 10.29, 10.09 10.04 10.08 13.23 12.00 9.31 10.17 10.52 10.10 9.96 10.02 10.04 14.33 13.00 9.26 10.23 10.44 10.02 9.92 9.98 9.99 15.43 14.00 9.21 10.26 10.34 9.96 9.87 9.93 9.94 16.53 15.00 9.16 10.28 10.22 9.91 9.83 9.88 9.88 17.64 16.00 9.11 10.27 10.12 9.86 9.78 9.84 9.83 18.74 17.00 9.06 10.23 10.05 9.82 9.74 9.79 9.77 19.84 18.00 9.00 10.16 9.98 9.77 9.69 9.74 9.72 20.94 19.00 8.95 10.10 9.93 9.72 9.64 9.69 9.66 22.05 20.00 8.90 10.03 9.87 9.68 9.60 9.64 9.60 23.15 21.00 8.84 9.98 9.81 9.63 9.55 9.59 9.55 24.25 22.00 8.79 9.92 9.76 9.59 9.51 9.55 9.49 25.35 23.00 8.73 9.86 9.70 9.54 9.47 9.50 9.44 26.46 24.00 8.68 9.80 9.65 9.50 9.42 9.45 9.38 27.56 25.00 8.62 9.74 9.59 9.45 9.38 9.41 9.33 33.07 30.00 8.23 9.46 9.33 9.22 9.18 9.20 9.06 38.58 35.00 7.42 9.21 9.09 9.00 8.98 8.99 8.37 40.85 37.06 7.08 9.03 8.92 8.81 8.78 8.79 8.04 44.09 40.00 6.61 8.77 8.67 8.53 8.49 8.51 7.57 49.60 45.00 5.81 8.08 8.01 7.90 7.90 7.91 6.77 54.42 49.37 4.26 55.12 50.00 7.37 7.38 7.28 7.29 7.19 5.97 58.61 53.17 4.55 60.63 55.00 6.61 6.76 6.56 6.42 6.05 62.34 56.55 5.28 63.16 57.30 5.28 63.48 57.59 5.33 63.54 57.65 5.25 64.66 58.66 5.26 70.00
] 63,50 4.26 5.33 5.26 5.25 5.28 5.28 4.55 Cycle 19 COLR Paqe 26 of 51 1
Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-2 MAPLHGR Limits for Rated Power and Rated Flow for GNF2 Fuel (cont.)
Average Planar Bundle Type: GNF2-P10DG2B388-6G6.0/7G5.0-100T2-145-T6-3143 (GNF2)
Exposure MAPLHGR Limit (kWlft)
Lat.
Lattice Lattice Lattice Lattice Lattice Lat.
GWd/MT GWd/ST 8661 8655 8656 8657 8658 8659 8667 0,00 0.00 9.53 8,53 8.73 8.87 8.88 8.53 10.20 0.22 0.20 9.44 8.58 8.78 8.92 8.91 8.56 10.14 1.10 1.00 9.23 8.68 8.89 9.04 9.00 8.66 9.98 2.20 2.00 9.16 8.83 9.05 9.20 9.12 8.78 9.92 3.31 3.00 9.17 8.98 9.22 9.37 9.25 8.91 9.93 4,41 4.00 9.20 9.14 9.39 9.55 9.38 9.05 9.95 5,51 5.00 9.24 9.30 9.57 9.71 9.51 9.19 9.98 6.61 6.00 9.27 9.46 9.71 9.85 9.65 9.35 10.01 7.72 7.00 9.31 9.58 9.84 9.99 9.80 9.50 10.03 8.82 8.00 9.33 9.68 9.96 10.05 9.93 9.65 10.05 9.92 9.00 9.36 9.77 10.07 10.09 10.06 9.79 10.07 11.02 10.00 9.37 9.85 10.17 10.13 10.17 9.92 10.08 12.13 11.00 9.35 9.90 10.25 10.18 10.26 10.00 10.08 13.23 12.00 9.31 9.94 10.29 10.20 10.29 10.04 10.04 14.33 13.00 9.26 9.97 10.32 10.21 10.23 10.07 9.99 15.43 14.00 9.21 10.00 10.35 10.23 10.21 10.08 9.94 16.53 15.00 9.16 10.03 10.36 10.20 10.18 10.07 9.88 17.64 16.00 9.11 10.04 10.37 10.17 10.15 10.06 9.83 18.74 17.00 9.06 10.04 10.36 10.13 10.11 10.05 9.77 19.84 18.00 9.00 10.04 10.35 10.09 10.07 10.03 9.72 20.94 19.00 8.95 10.04 10.31 10.04 10.02 10.01 9.66 22.05 20.00 8.90 10.03 10.26 10.00 9.97 9.99 9.60 23.15 21.00 8.84 10.02 10.20 9.95 9.93 9.97 9.55 24.25 22.00 8.79 10.01 10.15 9.90 9.88 9.92 9.49 25.35 23.00 8.73 10.01 10.09 9.86 9.84 9.87 9.44 26.46 24.00 8.68 10.00 10.03 9.81 9.79 9.83 9.38 27.56 25.00 8.62 9.99 9.98 9.76 9.75 9.78 9.33 33.07 30.00 8.23 9.88 9.71 9.54 9.54 9.56 9.06 38.58 35.00 7.42 9.45 9.47 9.33 9.34 9.30 8.37 40.85 37.06 7.08 9.17 9.27 9.07 9.10 9.02 8.04 44.09 40.00 6.61 8.77 9.00 8.70 8.75 8.63 7.57 49.60 45.00 5.81 8.07 8.28 8.00 8.04 7.93 6.77 54.42 49.37 4,26 55.12 50.00 7.36 7.56 7.28 7.30 7.20 5.97 58.61 53.17 4.55 60.63 55.00 6.59 6.82 6.47 6.45 6.08 62.39 56.60 5.28 63.22 57.35 5.28 63.28 57.41 5.27 63.44 57.55 5.33 64.62 58.62 5.26 70.00 63.50 4.26 5.33 5.26 5.27 5.28 5.28 4.55 Revision 32 Cycle 19 COLR Page 27 of 51 i
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 T~hl "1t.
MAPl W(RR I imit¢ fnr ~*r4if Pnuuir *=n, Q~*,r4 Plniuu fu*r (IMI:9 Piu~l (,nnt Average Planar Bundle Type: GNF2-PI0DG2B401-6G6.018G5.O11G4.0-100T2-145-T6-3421 (GNF2)
Exposure MAPLHGR Limit (kW/ft)
Lat.
Lat.
Lat.
[at.
Lat.
Lat.
Lat.
GWdIMT GWdIST 9676 9677 9678 9679 9680 9681 9682 0.00 0.00 9.53 8.80 8.93 9.03 8.47 8,19 10.20 0.22 0.20 9.44 8.84 8.97 9.07 8.50 8,22 10.14 1.10 1.00 9.22 8.91 9.05 9.16 8.58 8.31 9.97 2.20 2.00 9.16 8.99 9.14 9.26 8.70 8.43 9.92 3.31 3.00 9.16 9.08 9.24 9.36 8.81 8.55 9.92 4.41 4.00 9.19 9.17 9.33 9.46 8.93 8.68 9.95 5.51 5.00 9.23 9.25 9.43 9.56 9.05 8.82 9.98 6.61 6.00 9.27 9.34 9.53 9.66 9.18 8.95 10.01 7.72 7.00 9.30 9.43 9.63 9.76 9.30 9.10 10.03 8.82 8.00 9.33 9.52 9.73 9.87 9.43 9.24 10.05 9.92 9.00 9.35 9.61 9.83 9.97 9.57 9.39 10.06 11.02 10.00 9.37 9.71 9.94 10.08 9.70 9.52 10.07 12.13 11.00 9.34 9.76 10.02 10.17 9.79 9.62 10.08 13.23 12.00 9.30 9.81 10.07 10.22 9.87 9.71 10.04 14.33 13.00 9.26 9.85 10.12 10.25 9.94 9.79 9.99 15.43 14.00 9.21 9.89 10.17 10.18 10.00 9.86 9,93 16.53 15.00 9.16 9.93 10.20 10.14 10.04 9.90 9.88 17.64 16.00 9.10 9.95 10.22 10.10 10.01 9.93 9.82 18.74 17.00 9.05 9.97 10.23 10.06 9.97 9.95 9.77 19.84 18.00 9.00 9.98 10.22 10.01 9.92 9.97 9.71 20.94 19.00 8.94 9.98 10.16 9.97 9.87 9.92 9.65 22.05 20.00 8.89 9.98 10.10 9.92 9.82 9.87 9.60 23.15 21.00 8.83 9.98 10.04 9.87 9.77 9,81 9.54 24.25 22.00 8.78 9.98 9.98 9.81 9.72 9.76 9.48 25.35 23.00 8.72 9,98 9.93 9.76 9.68 9.71 9.43 26.46 24.00 8.67 9.97 9.87 9.71 9.63 9.66 9.37 27.56 25.00 8.61 9.95 9.81 9.67 9.58 9.61 9.32 33.07 30.00 8.21 9.64 9.52 9.41 9.36 9.37 9.05 38.58 35.00 7.40 9.37 9.26 9.16 9.14 9.14 8.36 40.85 37.06 7.07 9.18 9.10 8.99 8.95 8.96 8.03 44.09 40.00 6.60 8.92 8.88 8.74 8.68 8.70 7.56 49.60 45.00 5.80 8.22 8.20 8.08 8.06 8.07 6.76 54.38 49.33 4.25 55.12 50,00 7.50 7.55 7.44 7.44 7.34 5,96 58.58 53.14 4.55 60.63 55.00 6.67 6.91 6.72 6.68 6.43 63.11 57.25 5.30 63.39 57.51 5,41 63.79 57.87 5.30 64.60 58.60 5.35 64.67 58.67 5.17 70.00 63.50 4.25 5.41 5.35 5.17 5.30 5.30 4.55 Revision 32 Cycle 19 COLR Page 28 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-2 MAPLHGR Limits for Rated Power and Rated Flow for GNF2 Fuel (cont.)
Average Planar Bundle Type: GNF2-P10DG2B395-6G6.019G5.0-100T2-145-T6-3422 (GNF2)
Exposure MAPLHGR Limit (kW/ftL GWd/MT GWdIST Lat. 9676 Lat. 9683 Lat. 9684 Lat. 9685 Lat. 9686 Lat. 9687 Lat. 9682 0.00 0.00 9.53 8.87 9.01 9.11 8.60 8.32 10.20 0.22 0.20 9.44 8.92 9.06 9.17 8.64 8.37 10.14 1.10 1.00 9.22 9.00 9.16 9.27 8.75 8.48 9.97 2.20 2.00 9.16 9.11 9.30 9.41 8.90 8&64 9.92 3.31 3.00 9.16 9.22 9.44 9.56 9.07 8.79 9,92 4.41 4,00 9.19 9.34 9.58 9.71 9.24 8.94 9.95 5.51 5.00 9.23 9.47 9.72 9.87 9.41 9.09 9.98 6.61 6.00 9.27 9.60 9.87 10.03 9.56 9.25 10.01 7.72 7.00 9.30 9.73 10.00 10.17 9.71 9.42 10.03 8.82 8.00 9.33 9.63 9.94 10.16 9.87 9.59 10.05 9.92 9.00 9.35 9.42 9.69 9.88 10.02 9.75 10.06 11.02 10.00 9.37 9.45 9.71 9.87 10.12 9.90 10.07 12.13 11.00 9.34 9.55 9.82 9.97 10.24 10.00 10.08 13.23 12.00 9.30 9.65 9.94 10.10 10.08 10.07 10.04 14.33 13.00 9.26 9.71 10.01 10.13 10.05 10.11 9.99 15.43 14.00 9.21 9.77 10.07 10.08 10.01 10.07 9.93 16.53 15.00 9.16 9.81 10.10 10.04 9.98 10.04 9.88 17.64 16.00 9.10 9.84 10.13 10.00 9.95 10.00 9.82 18.74 17.00 9.05 9.86 10.13 9.96 9.90 9.95 9.77 19.84 18.00 9.00 9.87 10.10 9.92 9.86 9.90 9.71 20.94 19.00 8.94 9.88 10.05 9.87 9,81 9.85 9.65 22.05 20.00 8.89 9.88 9.99 9.82 9.76 9.80 9.60 23.15 21.00 8.83 9.89 9.93 9.77 9.71 9.75 9.54 24.25 22.00 8.78 9.89 9.87 9.72 9.66 9.70 9.48 25.35 23.00 8.72 9.89 9.82 9.67 9.61 9.65 9.43 26.46 24.00 8.67 9.90 9.76 9.62 9.57 9.60 9.37 27.56 25.00 8.61 9.84 9.70 9.57 9.52 9.55 9.32 33.07 30.00 8.21 9.55 9.43 9.32 9.30 9.32 9.05 38.58 35.00 7.40 9.28 9.17 9.08 9.07 9.08 8.36 40.85 37.06 7.07 9.10 9.00 8.90 8.88 8.89 8.03 44.09 40.00 6.60 8.83 8.76 8.64 8.60 8.62 7.56 49.60 45.00 5.80 8.13 8.10 7.99 7.99 8.00 6.76 54.38 49.33 4.25 55.12 50.00 7.42 7.46 7.35 7.37 7.26 5.96 58.58 53.14 4.55 60.63 55.00 6.68 6.83 6.64 6.60 6.22 62.67 56.86 5.29 63.51 57.61 5.29 63.72 57.81 5.32 64.12 58.17 5.18 64.95 58.93 5.28 70.00 63.50 4.25 5.32 5.28 5.18 5.29 5.29 4.55 Cycle 19 COLR Page 29 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-2 MAPLHGR Limits for Rated Power and Rated Flow for GNF2 Fuel (cont.)
Average Planar Bundle Type: GNF2-P10DG2B375-6G6.0/7G5.0-100T2-145-T6-3434 (GNF2)
Exposure MAPLHGR Limit (kW/ft)
Lat.
Lat.
Lat.
Lat.
Lat.
Lat.
Lat.
GWd/MT GWdlST 9676 9688 9689 9690 9691 9692 9682 0.00 0.00 9.53 8.80 8.99 9.08 8,56 8.22 10.20 0.22 0.20 9.44 8.82 9.02 9.13 8.60 8.26 10.14 1.10 1.00 9.22 8.91 9.12 9.24 8.70 8.37 9.97 2.20 2.00 9.16 9.03 9.25 9.36 8.83 8.50 9.92 3.31 3.00 9.16 9.15 9.38 9.49 8.97 8.64 9.92 4.41 4.00 9.19 9.27 9.52 9.62 9.11 8.79 9.95 5.51 5,00 9.23 9.41 9.65 9.71 9.25 8.94 9,98 6.61 6.00 9.27 9.54 9.78 9.76 9.40 9.10 10.01 7.72 7.00 9.30 9.16 9.42 9.63 9.55 9.26 10.03 8.82 8.00 9.33 8.84 9.07 9.24 9.48 9.42 10.05 9.92 9.00 9.35 8.85 9.05 9.20 9.43 9.51 10.06 11.02 10.00 9.37 8.95 9.17 9.30 9.55 9.62 10.07 12.13 11.00 9.34 9.07 9.31 9.44 9.70 9.76 10.08 13.23 12.00 9.30 9.15 9.40 9.54 9.82 9.81 10.04 14.33 13.00 9.26 9.23 9.48 9.62 9.89 9.83 9.99 15.43 14.00 9.21 9.30 9.55 9.68 9.95 9.84 9.93 16.53 15.00 9.16 9.35 9.60 9.73 9.96 9.84 9.88 17.64 16.00 9.10 9.40 9.64 9.76 9.93 9.84 9.82 18.74 17.00 9.05 9.44 9.67 9.78 9.89 9.82 9.77 19.84 18.00 9.00 9.47 9.69 9.80 9.85 9.81 9.71 20.94 19.00 8.94 9.50 9.70 9.81 9.80 9.79 9.65 22.05 20.00 8.89 9.52 9.72 9.77 9.76 9.78 9.60 23.15 21.00 8.83 9.55 9.74 9.72 9.71 9.75 9.54 24.25 22.00 8.78 9.57 9.76 9.68 9.67 9.71 9.48 25.35 23.00 8.72 9.60 9.78 9.64 9.63 9.66 9.43 26.46 24.00 8.67 9.62 9.80 9.59 9.59 9.62 9.37 27.56 25.00 8.61 9.64 9.76 9.55 9.55 9.58 9.32 33.07 30.00 8.21 9.72 9.51 9.35 9.35 9.37 9.05 38.58 35.00 7.40 9.24 9.29 9.16 9.18 9.07 8.36 40.85 37.06 7.07 8.96 9.08 8.88 8.92 8.80 8.03 44.09 40.00 6.60 8.57 8.78 8.48 8.54 8.42 7.56 49,60 45.00 5.80 7.89 8.08 7.80 7.84 7.74 6.76 54.38 49.33 4.25 55.12 50.00 7.19 7.37 7.09 7.12 7.01 5.96 58.58 53.14 4.55 60.63 55.00 6.10 6.62 5.97 5.93 5.55 61.27 55.59 5.26 62.10 56.33 5.26 62.24 56.46 5.24 62.37 56.58 5.32 63.46 57.57 5.34 70.00 63.50 4.25 5.32 5.34 5.24 5.26 5.26 4.55 Cycle 19 COLR Page 30 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-2 MAPLHGR Limits for Rated Power and Rated Flow for GNF2 Fuel (cont.)
Average Bundle Type: GNF2-P1ODG2B401-6G6.012G5.0/6G4.0-100T2-145-T6-3640 (GNF2)
Planar MAPLHGR Limit (kW/ft)
Exposure Lat.
Lat.
Lat.
Lat.
Lat.
Lat.
Lat.
1 9676 9693 9694 9695 9696 9697 9682 0.00 0.00 9.53 8.82 8.96 9.08 8.51 8.23 10.20 0.22 0.20 9.44 8.87 9.00 9.12 8.55 8.27 10.14 1.10 1.00 9.22 8,94 9.08 9.20 8.63 8.36 9.97 2.20 2.00 9.16 9.03 9.18 9.30 8.75 8.48 9.92 3.31 3.00 9.16 9.12 9.28 9.41 8.87 8.62 9.92 4.41 4.00 9.19 9.21 9.38 9.51 9.00 8.75 9.95 5.51 5.00 9.23 9.30 9.49 9.62 9.13 8.90 9.98 6.61 6.00 9.27 9.40 9.59 9.73 9.26 9.04 10.01 7.72 7.00 9.30 9.49 9.70 9.84 9.40 9.20 10.03 8,82 8.00 9.33 9,59 9.81 9.96 9.54 9.35 10.05 9.92 9.00 9.35 9.69 9.92 10.07 9.68 9.51 10.06 11.02 10.00 9.37 9.79 10.04 10.18 9.82 9.64 10.07 12.13 11.00 9.34 9.85 10.12 10.28 9.90 9.73 10.08 13.23 12.00 9.30 9.90 10.17 10.32 9.96 9.80 10.04 14.33 13.00 9.26 9.93 10.21 10.32 10.01 9.85 9.99 15.43 14.00 9.21 9.96 10.24 10.24 10.04 9.90 9.93 16.53 15.00 9.16 9.98 10.25 10.18 10.06 9.92 9.88 17.64 16.00 9.10 9.99 10.25 10.13 10.03 9.94 9.82 18.74 17.00 9.05 10.00 10.24 10.08 9.98 9.95 9.77 19.84 18.00 9.00 10.00 10.23 10.03 9.93 9.96 9.71 20.94 19.00 8.94 9.99 10.16 9.97 9.88 9.92 9.65 22.05 20.00 8.89 9.99 10.10 9.92 9.83 9.87 9.60 23.15 21.00 8.83 9.99 10.04 9.87 9,78 9.82 9.54 24.25 22.00 8.78 9.98 9.98 9.82 9.73 9.77 9.48 25.35 23.00 8.72 9.98 9.92 9.77 9.68 9.72 9.43 26.46 24.00 8.67 9.97 9.86 9.72 9.63 9.67 9.37 27.56 25.00 8.61 9.95 9.81 9.67 9.59 9.62 9.32 33.07 30.00 8.21 9.64 9.52 9.41 9.36 9.38 9.05 38.58 35.00 7.40 9.36 9.25 9.16 9.13 9.14 8.36 40.85 37.06 7.07 9.18 9.10 8.99 8.95 8.96 8.03 44.09 40.00 6.60 8.93 8.88 8.75 8.69 8.71 7.56 49,60 45.00 5.80 8.23 8.21 8.09 8.06 8.08 6.76 54,38 49.33 4.25 55.12 50.00 7.51 7.55 7.44 7.45 7.34 5.96 58.58 53.14 4.55 60.63 55.00 6.69 6.91 6.73 6.68 6.46 63.19 57.32 5.30 63.45 57.56 5.41 63.85 57.92 5.29 64.65 58.65 5.34 64.66 58.66 5.17 70.00 63.50 4.25 5.41 5.34 5.17 5.29 5.30 4.55 Revision 32 Cycle 19 COLR I Page 31 of 51 l
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G Table 3.1-2 MAPLHGR Limits for Rated Power and Rated Flow for GNF2 Fuel (cont.A 4.02 Table.3.1-2.......................d..wer...d.Ra.e...lo.fo.......Fue...con.)..
Average Planar Bundle Type: GNF2-P1 0DG2B406-6G6.016G5.0/2G4.0-1 00T2-145-T6-3641 (GNF2)
Exposure MAPLHGR Limit (kW/ft)
GWd/MT GWd/ST Lat. 9676 Lat. 9698 Lat. 9699 Lat. 9700 Lat. 9701 Lat. 9702 Lat. 9682 0.00 0.00 9.53 8.79 8.93 9.03 8.46 8.19 10.20 0.22 0.20 9.44 8.83 8.98 9.08 8.50 8.23 10.14 1.10 1.00 9.22 8.91 9.06 9.17 8.59 8.33 9.97 2.20 2.00 9.16 9.00 9.17 9.28 8.72 8.46 9.92 3.31 3.00 9.16 9.10 9.29 9.40 8.85 8.60 9.92 4.41 4.00 9.19 9.21 9.40 9.52 8.99 8.75 9.95 5.51 5.00 9.23 9.31 9.52 9.64 9.14 8.90 9.98 6.61 6.00 9.27 9.39 9.63 9.76 9.29 9.06 10.01 7.72 7.00 9.30 9.47 9.73 9.86 9.41 9.20 10.03 8.82 8.00 9.33 9.55 9.83 9.97 9.54 9.34 10.05 9.92 9.00 9.35 9.63 9.93 10.07 9.67 9.49 10.06 11.02 10.00 9.37 9.71 10.03 10.17 9.80 9.63 10.07 12.13 11.00 9.34 9.76 10.12 10.27 9.89 9.72 10.08 13.23 12.00 9.30 9.79 10.17 10.32 9.97 9.81 10.04 14.33 13.00 9.26 9.82 10.22 10.34 10.04 9.89 9.99 15.43 14.00 9.21 9.84 10.23 10.27 10.09 9.95 9.93 16.53 15.00 9.16 9.86 10.24 10.22 10.12 9.99 9.88 17.64 16.00 9.10 9.87 10.23 10.18 10.09 10.01 9.82 18.74 17.00 9.05 9.87 10.22 10.13 10.05 10.03 9.77 19.84 18.00 9.00 9.87 10.20 10.09 10.00 10.04 9.71 20.94 19.00 8.94 9.86 10.18 10.04 9.95 10.00 9.65 22.05 20.00 8.89 9.84 10.16 9.99 9.90 9.94 9.60 23.15 21.00 8.83 9.83 10.12 9.93 9.85 9.89 9.54 24.25 22.00 8.78 9.81 10.06 9.88 9.80 9.84 9.48 25.35 23.00 8.72 9.80 10.00 9.83 9.75 9.79 9.43 26.46 24.00 8.67 9.78 9.94 9.78 9.70 9.74 9.37 27.56 25.00 8.61 9.76 9.88 9.73 9.66 9.69 9.32 33.07 30.00 8.21 9.69 9.58 9.47 9.42 9.44 9.05 38.58 35.00 7.40 9.21 9.31 9.22 9.19 9.20 8.36 40.85 37.06 7.07 8.95 9.14 9.05 9.01 9.03 8.03 44.09 40.00 6.60 8.58 8.89 8.81 8.75 8.78 7.56 49.60 45.00 5.80 7.92 8.21 8.15 8.12 8.14 6.76 54.38 49.33 4.25 55.12 50.00 7.23 7.51 7.50 7.50 7.41 5.96 58.58 53.14 4.55 60.63 55.00 6.07 6.76 6.78 6.75 6.64 62.21 56.44 5.35 63.60 57.69 5.29 63.79 57.87 5.37 64.18 58.23 5.27 64.44 58.45 5.3 0 70.001 63.50 4.25 5.35 5.37 5.30 5.27 5.29 4.55 Revision 32 Cycle 19 COLR Page 32 of 51 1
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Table 3.1-2 MAPLHGR Limits for Rated Power and Rated Flow for GNF2 Fuel (cont.)
Average Planar Bundle Type: GNF2-P10DG2B407-6G6.0/2G5.0/6G4.0-100T2-145-T6-3642 (GNF2)
Exposure MAPLHGR Limit (kW/ft_
Lat.
Lat.
Lat.
Lat.
Lat.
Lat.
Lat.
GWdlMT GWd/ST 9676 9703 9704 9705 9706 9707 9682 0.00 0.00 9.53 8.58 8.69 8.79 8.49 8.22 10.20 0.22 0.20 9.44 8.63 8.74 8.83 8.53 8.26 10.14
).
10 1.00 9.22 8.70 8.81 8.91 8.62 8.36 9.97 2.20 2.00 9.16 8.79 8.91 9.01 8.75 8.50 9.92 3.31 3.00 9.16 8.88 9.01 9.11 8.89 8.65 9.92 4.41 4.00 9.19 8.97 9.12 9.22 9.04 8.80 9.95 5.51 5.00 9,23 9.07 9.22 9.32 9.20 8.96 9.98 6.61 6.00 9.27 9.16 9.33 9.43 9.36 9.14 10.01 7.72 7.00 9.30 9.26 9.43 9.55 9.50 9.29 10.03 8.82 8.00 9.33 9.36 9.55 9.66 9.64 9.44 10.05 9.92 9.00 9.35 9.46 9.66 9.78 9.78 9.59 10.06 11.02 10.00 9.37 9.56 9.77 9.89 9.91 9.73 10.07 12.13 11.00 9.34 9.61 9.84 9.97 9.99 9.81 10.08 13.23 12.00 9.30 9.66 9.90 10.02 10.05 9.88 10.04 14.33 13.00 9.26 9.70 9.94 10.06 10.10 9.94 9.99 15.43 14.00 9.21 9.72 9.96 10.08 10.13 9.98 9.93 16.53 15.00 9.16 9.73 9.97 10.08 10.15 10.01 9.88 17.64 16.00 9.10 9.74 9.96 10.07 10.11 10.02 9.82 18.74 17.00 9.05 9.73 9.95 10.05 10.06 10.03 9.77 19.84 18.00 9.00 9.72 9.93 10.03 10.01 10.04 9.71 20.94 19.00 8.94 9.71 9.91 10.01 9.96 10.01 9.65 22.05 20.00 8.89 9.69 9.89 9.99 9.91 9.95 9.60 23.15 21.00 8.83 9.68 9.88 9.97 9.86 9.90 9.54 24.25 22.00 8.78 9.67 9.86 9.91 9.81 9.85 9.48 25.35 23.00 8.72 9.66 9.84 9.86 9.76 9.80 9.43 26.46 24.00 8.67 9.64 9.83 9.81 9.71 9.74 9.37 27.56 25.00 8,61 9.63 9.81 9.76 9.66 9.69 9.32 33.07 30.00 8.21 9.58 9.60 9.49 9.43 9.45 9.05 38.58 35.00 7.40 9.05 9.27 9.23 9.20 9.20 8.36 41).85 37.06 7.07 8.80 9.01 9.03 9.02 9.03 8.03 44.09 40.00 6.60 8.43 8.64 8.73 8.77 8.79 7.56 49.60 45.00 5.80 7.78 7.98 8.06 8.13 8.15 6.76 54.38 49.33 4.25 55.12 50.00 7.08 7.27 7.36 7.51 7.42 5.96 58.58 53.14 4.55 60.63 55.00 5.65 6.16 6.40 6.75 6.64 61.35 55,66 5.32 62.41 56.62 5.36 62.90 57.06 5.37 63.63 57.73 5.29 64.28 58.32 5.26 70.00 63.50 4.25 5.32 5.36 5,37 5.26 5.29 4.55 Revision 32 Cycle 19 COLR Page 33 of 51 1
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 3.1-1 Most limiting MAPLHGR 10.0 T-9.710. 1
-T 9.94 q
-4
35 4 9 7,
9.18
'8.98
-- GN 2 GE14F IIi:
- 1~
.9.254--
9.0 8
- 54 1 I.
L i i=
8ý8
-37rI
!i.
i 8.0 a
- a. ~
0~
~ ~
4
-4 CD 7.0 ra 7.73~
71i*!:
1, 71~
1 7.
7.0
- t 6.0 4 INote:
MAPLHGR limits used by 3D Monicore are lattice specific and are listed in Section 16.3 in the Supplemental Reload Licensing Report. Most Limiting MAPLHGR limit in any lattice is shown in this figure as a function of average planar exposure. Natural Uranium lattices are excluded from this figure. Use tables for accurate calculations if necessary.
EL.
4.,
[A I
i I~t~
II f~
I
]
a.. -
i a
~
a 5.64
,.*... 1 t-51 S
, ~
a -
5.17 5.0 I 1 1 ! 1 i :
I l i l = ! l l i l i 1 1 1
- I i 1 1 1 1 i *
.~-I V4-~j ~riii~vti J
N4. ý214 4.0 I1!
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 Average Planar Exposure (GWd/ST)
Cycle 19 COLR Page 34 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT Figure 3.1-2 Flow Dependent MAPLHGR Factor (MAPFACF)
RTYPE: G4.02 1.1 1.0 0.9 C.,
0,.
0.8 II I
j r
L4 F
t L iI r10 0.62 4
I 0.7 0.6 0.5 30 40 60 70 Core Flow %
80 90 100 110 Revision 32 Cycle 19 COLR Page 35 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4,02 Note: These MAPFACp factors are valid for Turbine bypass in or out of service and for Normal Feedwater heating 1
0.95 0.9 0.85 0.8 0.75 CL U.
0.7 0.65 0.6 0.55 0.5 0.45 0.4 0.35 0.3 Revision 32 Cycle 19 COLR Page 36 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 3.2 Linear Heat Generation Rate (LHGR)
Reference Technical Specification: 3.11..B When reactor power is greater than 25%, the LHGR of any rod in any fuel assembly at any axial location shall not exceed the rated power and rated core flow limits presented in Reference 5.17. Figure 3.2-1 represents LHGR curves for GE14 fuel. Proprietary detailed values for both GE14 and GNF2 fuels are in Reference 5.17. At other than rated power and rated flow conditions, the applicable limiting LHGR value for each fuel type is the smaller of the flow-and power-dependent LHGR limits, LHGRF and LHGRp. The flow-dependent LHGR limit, LHGRF, is the product of the LHGR flow factor, LHGRFACF, shown in Figure 3.2-2 and the LHGR for rated power and flow conditions in Reference 5.17. The power-dependent LHGR limit, LHGRp, is the product of the LHGR power factor, LHGRFACp, shown in Figure 3.2-3 and the LHGR for rated power and flow conditions in Reference 5.17.
LHGR Curves in Figure 3.2-1 are representative curves for U02 fuel rods and Gd containing rods for GE14 Fuel. A Figure comparable to Figure 3.2-1 for GNF2 is not included because GNF has requested Entergy to protect this proprietary information. Gd containing fuel rods have different LHGR limits that are also exposure dependent. Reference 5.17 documents the detailed proprietary curves and values for both GE14 and GNF2 fuels.
Reference 5.23 documents the GESTAR II compliance of GNF2 fuel, as amended. Amendment 33 to GESTAR II incorporated Prime T-M methods. Cycle 19 LHGR limits are based on using PRIME for U02 fuel rods and GESTR-M for Gd rods, as GESTR-M limits for Gd rods are more conservative.
Pbypass is the power level below which more restrictive thermal limits are applied, as Turbine Stop Valve closure and Turbine Control Valve Fast Closure scrams are assumed to be bypassed. Pbypass can be set in anywhere in the range 32.5 to 45% core thermal power.
Pbypass is currently set at 32.5% power.
Cycle 19 COLR Revision 32 Page 37 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 3.2-1 Most Limiting LHGR for GE14 Fuel At Rated Power and rated Core Flow 14 13 12 11t 10
-9
.E W 6 L0
-5 4
0 10 20 30 40 50 60 70 Exposure, GWD/ST Revision 32 Cycle 19 COLR Page 38 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 3.2-2 Flow Dependent LHGR Factor (LHGRFACF)
'0-C-,
-J 1.1 1.0 0.9 0.8 0.7 0.6 0.5 30 40 50 60 70 80 90 100 110 Core Flow %
Revision 32 Cycle 19 COLR Page 39 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 3.2-3 Power Dependent LHGR Factors Note: These LHGRFACp factors are valid for Turbine bypass in or out of service and for Normal Feedwater heating 0.95 0.9 0.8590 0
Vo.875~
P.
.P......s 0.8 f32.5,0.83z 0.75 P >
- PPbypass, For P, % power > Pbypass and 32.5% : Pbypass 545%
0.7 0 Core Flow < 50%, P S Pbypass, where 065 32.5%!5 Pbypass 5 45%
0.6 45_ 0.557 0.55 32..
5 0. 49 25 0.45.
45, 0.537; I.
_I I_
_i 0.4~ ~~~
0.4......
25,5 03459 L....- '
Care-Flow > 50%, PS* Pbypass, where l
0.4 T---*'!
i i
1 32.5%:s Pbypass 5 45%/**-
0.3 5..,_
25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 10(
% Power Cycle 19 COLR Revision 32 Page 40 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 3.3 Minimum Critical Power Ratio (MCPR)
Reference Technical Specification: 3.11.C During power operation, the MCPR shall be greater than or equal to the Operating Limit MCPR (OLMCPR). The operating limit MCPR is the greater of the flow-and power-dependent MCPR operating limits, MCPRF and MCPRp. The flow-dependent MCPR operating limit, MCPRF, is provided in Figure 3.3-1.
For power level less than Pbypass, the MCPRp is independent of the fuel type and can be directly read from Figure 3.3-2, when Turbine Bypass is operable and from Figure 3.3-3, when Turbine Bypass is out of service.
Above PBy "ss MCPRp is the product of the rated power and flow MCPR operating limit presentediTable 3.3-7, and the Kp factor presented in Figure 3.3-2, when Turbine Bypass is in service and from Figure 3.3-3, when Turbine Bypass is out of service. The rated power and flow MCPR operating limits presented in Tables 3.3-1 are functions of T.
Both Figures 3.3-2 and 3.3-3 include normal and reduced feed water temperature operating modes. For SLO MCPRp and MCPRF are raised by 0.03 compared to TLO values shown in Figures 3.3-2 and 3.3-3.
The value of - in Table 3.3-1 shall be equal to 1.0, unless it is calculated from the results of the surveillance testing of Technical Specification 4.3.C. TS 4.11.C defines T.
Pbypass is the power level below which more restrictive thermal limits are applied, as Turbine Stop Valve Closure and Turbine Control Valve Fast Closure scrams are assumed to be bypassed. Pbypass can be set anywhere in the range 32.5% to 45% core thermal power.
Pbypass is currently set at 32.5%.
Cycle 19 COLR Revision 32 Page 41 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT Table 3.3-1 RTYPE: G4.02 MCPR Operatingq Limits At Rated Power and Rated Flow The MCPR Operating Limit for Two Loop Operation (OLMCPRTLO) is a function of fuel type, exposure, and T, which is derived from scram timing measurements.
Tau GNF2 GE14 BOC to MOC MOC to EOC BOC to MOC MOC to EO5 From To 0.0 1.50 1.55 1.46 1.51 0.0 0.1 1.51 1.56 1.48 1.53 0.1 0.2 1.52 1.57 1.49 1.55 0.2 0.3 1.53 1.58 1.50 1.57 0.3 0.4 1.54 1.59 1.51 1.58 0.4 0.5 1.55 1.60 1.52 1.60 0.5 0.6 1.56 1.61 1.53 1.62 0.6 0.7 1.57 1.62 1.54 1.63 0.7 0.8 1.58 1.63 1.55 1.65 0.8 0.9 1.59 1.64 1.56 1.67 0.9 1.0 1.60 1.65 1.57 1.68 BOC = Beginning Of Cycle MOC = Middle of Cycle = End Of Rated Power Operation At Rated Flow (EOR) - 1.455 GWd/ST EOC = End Of Cycle Note: The rated OLMCPR Limits given above apply to both normal and reduced Feedwater Temperature as well as Turbine Bypass Valve OOS and Turbine bypass Valves in service. Off rated MCPR limits are given in Figures 3.3-1, 3.3-2 and 3.3-3 as taken from the Supplemental Reload Licensing Report (Reference 5.15).
Single Loop Operation OLMCPR SLO = 0.03 + OLMCPR TLO, where OLMCPR TLO is selected from the Table above.
Cycle 19 COLR Revision 32 Page 42 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 3.3-1 Flow Dependent MCPR Limits (MCPR F) 1.7 0
0 I0 0.
Q I.)
1.5
- 30. 1 58 A
4.
'-1
--a.
1.
'1 i Ph ii a,.:
A...........
O-iJ~ l ii"....Z
~ o....................
I ~ & --
-- ~.£ ~ 4
".I.....~........
I For SLO MCPRf is raised by 0.03 c ompared to TLO values.
--a -----I
'I
-t
'14 F
- i *"Pt-d* d:-
1.4 1.3
-i IT j-.
-4.
'4 4-
+
-a-a-a-4f
- ..=*
Kt!4-T TI I-i "I92i 1-20 I. i4.L F
- 2. 1 201 12
- -'. *71
- 1 1~
-'--I---.I -1 TflT-1
+rr 4-Ii I..
'-1 i
-VTo V
T Me 1.1 --I-----I A
I I ~~-"-.4-----4
~---+
4--*---I 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 Core Flow, % Of Rated Cycle 19 COLR Revision 32 Page 43 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 3.3-2 Power Dependent MCPR Limits (MCPRp)
Turbine Bypass is Assumed Operable and Normal and Reduced Feedwater Temperature 3.50 A
132-5, 3:01 3.00 A
OLMCPR for 25% < P
- Pbypass az 50%
...= %
145,2.58 A
nd Core Flow >
2.50
-J 0
02.00 CL ij I
'K [5.20 1.50 1 When P 5 Pbypass and in SLO, OLMCPRp is raised by 0.03 compared to TLO values. When P,>
Pbypass and in SLO, the rated OLMCPR is raised by 0.03 before multiplying by Kp to calculate OLMCPRp.
i 'i i...........
i;i Kp for P > Pbypass P = % Power and 45% > Pbypass >
.32 5,1.253
~10 o~~I 1100. 1.0 1.00 25 45 65 85 Power (%)
Cycle 19 COLR Page 44 of 51 Revision 32
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 Figure 3.3-3 Power Dependent MCPR Limits (MCPRp)
Turbine Bypass is Assumed Out of Service and Normal and Reduced Feedwater Temperature Fý. 4=48j 450-C 0~
0 Y.
4.00 3.50 3.00 Q.50 2.00 1.50 When P s Pbypass and in SLO. OLMCPRp is raised by 0.03 compared to TLO values. When P > Pbypass and in SLO. the S.........
rated OLMCPR is raised by 0.03 before multiplying by Kp to calculate OLMCPRp.
OLMCPR for 25%
P 50%
P % Power and 45% > Pbypass > 32.5%
l
.. t.."
j12ý5.2.98~
- i m,,........
=***
OLMCPR for 25%:S PS5 Pbypass and Core Flow S 50%
P % Power and 45% > Pbypass > 32.5%
5=,22
- i ".....
Kp for P > Pbypass P = % Power and 45% > Pbypass > 32.5%
L32~5.1253I L4.1.2o1
=~.196I-85.0 1.00 1.UU RF 25 35 45 55 65 75 85 95 Power (%)
Revision 32 Cycle 19 COLR Page 45 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 3.4 Power/Flow Relationship Durinq Power Operation Reference Technical Specification: 3.11.D The Cycle 19 stability analysis does not credit the flow clamp feature of the FCTR cards. The dominance of Core Wide Oscillations was demonstrated without the use of the flow clamp. APRM Flux scram and Rod Block curves without the flow clamp are therefore applicable to Cycle 19.
The power/flow relationship shall not exceed the limiting values shown on the Power/Flow Operating Maps in Figures 3.4-1 when in Two Loop Operation and 3.4-2 when in Single Loop Operation.
Cycle 19 operation is not fully analyzed for reduced feedwater temperature for issues other than thermal limits. This report contains only the thermal limit analysis results for reduced feed water temperature mode.
The exclusion and the buffer regions shown in Figures 3.4-1 and 3.4-2 are based on Stability Solution I-D (references 5.4, 5.12, 5.15 and 5.2OCycle 19 Stability Analysis utilizes Reference 5.24 ODYSY LTR that removed the decay ratio adder of 0.15. Figures 3.4-1 and 3.4-2 show APRM Scram and Rod Block lines using Allowable values as a function of Core Flow.
Single Loop Analysis limits maximum Core Flow to 52% of Rated Core Flow and maximum Power to 65% of Rated due to SLO vessel internal vibration (Ref. 5.7, p. 1-2).
Various lines on the Power to flow map are described in Ref. 5.14.
Revision 32 Cycle 19 COLR Page 46 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 FIGURE 3.4-1 PILGRIM POWER I FLOW MAP - Two Loop Operation Scram and Rod Block Data based on Allowable Values CORE FLOW, MLB/HR
-J ul I-0 C.)
125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 6
0 2536 2434 2332 2231 2129 2028 1927 1825 1724 1622 1521 1420 1318 1217 1116 1014 913 811 710 608 507 406 304 203 101 0
w 0
0.
-4J I--
LU 0
C) 0 5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 CORE FLOW, MLBIHR Revision 32 Cycle 19 COLR Page 47 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 FIGURE 3.4-2 PILGRIM POWER i FLOW MAP - Single Loop Operation Scram and Rod Block Data based on Allowable Value Setpoint CORE FLOW, MLBIHR 0
5 10 I5 20 25 30 35 40 45 s0 55 60 65 70 75 g0 a
a:
0.
-J 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5
0 2535 2434 2332 2231 2129 2028 1927 1825 1724 1622 1521 1420 1318 1217 1115 1014 913 811 710 608 507 406 304 203 101 0
a.
-J Lu I-LL 0
C.)
0 5
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 CORE FLOW, MLBIHR 0
Revision 32 Cycle 19 COLR Page 48 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 4.0 REACTOR VESSEL CORE DESIGN Reference Technical Specification: 4.2 The reactor vessel core for the present cycle consists of 580 fuel assemblies of the types listed below. The core loading pattern (Ref. 5.15) for each type of fuel is shown for the present cycle in Figure 4.0-1.
Cycle Fuel Type Load Number Irradiated:
GE1 4-P1 ODNAB399-1 0G6.0/3G5.0/1 G2.0-1 OOT-1 45-T6-2828 16 67 GE14-P1ODNAB398-8G6.0/5G5.0/2G4.0-1OOT-145-T6-2829 (GE14C) 16 45 GE14-P1ODNAB399-15GZ-10OT-145-T6-2957 (GE14C) 17 32 GE14-P1ODNAB398-5G6.0/10G5.0-10OT-145-T6-2958 (GE14C) 17 32 GE14-P1ODNAB400-13GZ-10OT-145-T6-2959 (GE14C) 17 24 GE14-P1ODNAB404-5G6.0/10G5.0-10OT-145-T6-2960 (GE14C) 17 40 GE14-P1ODNAB400-12G6.0/3G5.0-10OT-145-T6-2961 (GE14C) 17 32 GNF2-P 10DG2B389-6G6.018G5.0-100T2-145-T6-3141 (GNF2) 18 16 GNF2-P 10DG2B389-6G6.0/2G5.0/6G4.0-100T2-145-T6-3142 (GNF2) 18 104 GNF2-P 10DG2B388-6G6.0/7G5.0-100T2-145-T6-3143 (GNF2) 18 36 New:
GNF2-P 1ODG2B401-6G6.0/8G5.0/1G4.0-100T2-145-T6-3421 (GNF2) 19 24 GNF2-P 10DG2B395-6G6.0/9G5.0-100T2-145-T6-3422 (GN F2) 19 16 GNF2-P 10DG2B375-6G6.0/7G5.0-100T2-145-T6-3434 (GNF2) 19 16 GNF2-P 1ODG2B401-6G6.0/2G5.0/6G4.0-100T2-145-T6-3640 (GNF2) 19 36 GNF2-P10DG2B406-6G6.0/6G5.0/2G4.0-100T2-145-T6-3641 (GNF2) 19 16 GNF2-P10DG2B407-6G6.0/2G5.0/6G4.0-100T2-145-T6-3642 (GNF2) 19 44 Total:
580 The reactor vessel core contains 145 cruciform-shaped control rods. The control materials used are either boron carbide powder (B4 C) compacted to approximately 70%
of the theoretical density or a combination of boron carbide powder and solid hafnium.
Cycle 19 COLR Revision 32 Page 49 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02 FIGURE 4.0-1 Reactor Vessel Core Loading Pattern Mn CIE[] [][]
E[]
A
=
A, [
EDEU K9ND 01M E30
=
Mll Eli M1D
= = llmn E11MDIM M0=00-EDOM E
4E]
[]
H M]
'5
,5 H7 WE A=G1 4-100NABO4-G./I0
=
-3 T14-626 (yl 7
D1 G CUE] 01171 28 l
G10ODIM Elio 014 (l 21 0 G
-lCO
[]
284O 1G /0104CO 10T 6-C 19 Fuel ly..1e A=GE14-PI0DNA8404-5G6.0/I0GS.0--100T-14S-Tr-2960 (Cycle 17)
B=GE14-PI0DNAB398-5GG.O/100 T-145-T6-2959 (Cycle 17)
C--GE14-PlODNA8399-5OG6.0/3GS.0/ZG2.01TOT-145-TG92828 (Cycle 16)
D=GNF2-P0ODG28388-6G6.0/TGS.0--I0 T2-145-T6-3143 (Cycle 18)
E=GNF2-P100G28395-6G6.0/9GS.0-100T2-145-TG-3422 (Cycle 19)
F=GNF2-PCODG2401-6G6.O/SGS.O/264,0-100T2-145S.T6-3421 (Cycle 19)
G--ME14-P1O NAB4,00-12t3GZ-tOOT-.145-T6,-29"9 (Cycl e
17)
H---GE14-Pl0ONA8399-15GZ-10(]T-145-T6-.2957 (Cycle 17)
I=GNF2-P100G28389-6G6.O/8GSO/0T-1.-T2-14546-314 2
(Cycle 18)
J-ONF2-P1ODG23407-6G6.0/2G5.0/6G4.0-100T2-145-T6-3642 (Cycle 19)
K=GE 14-P tODNAB398 oSGr.0,/SGS.O/2G4.0, tOOT-145,-T6-2829 (Cycle 16)
L=GNF2.PICOG2B406-6G6.0/6GS.0`/2G4.0.100T2-145.TC-3641 (Cycle 19)
.M=fýE14-PIODNAB400-1.ZG6.013G5.0-10OT-14.5-T6-2951 (Cycle 17)
N=GNF2-PIODG2B389-6G6,0/2G5.O/'6"4,0-100T2.145-r6,-31.42 (Cycle 18)
O=GNF2-PIODG28375-6G6,0/7GS.0.100T2-145-T6-3434 (Cycle 19)
P=GNF 2-P "ODG2401-6G6.0/2GS.0/6G4.0-10OT2-145-TG-3640 (Cycle 19)
Cycle 19 COLR Revision 32 Page 50 of 51
PILGRIM NUCLEAR POWER STATION PNPS CORE OPERATING LIMITS REPORT RTYPE: G4.02
5.0 REFERENCES
5.1.
NEDE-24011 -P-A-17 and NEDE-24011-P-A-1 7-US, "General Electric Standard Application for Reactor Fuel", September 2010, eB record: RA-ENO-GEN-10-147.
5.2.
EC17226, Cycle 19 Reload Core Design.
5.3.
NEDC-31852-P, rev. 4, "Pilgrim Nuclear Power Station SAFER/GESTR-LOCA Loss-of-Coolant Accident Analysis for PNPS", January 2008.
5.4.
NEDC-33155P, Rev.0, Application of Stability Long-Term Solution Option I-D To Pilgrim Nuclear Power Station, October 2004.
5.5.
Letter 1.09.015, Letter from the NRC approving TS Amendment 232 for Cycle 18 SLMCPR.
5.6.
GE-NE-GENE-0000-0033-6871-01, Rev. 0, Pilgrim Option I-D APRM Flow Biased Set points, October 2004.
5.7.
GE-NE-0000-0027-5301, Rev 2, Pilgrim Nuclear Power Station Single Loop Operation, April 2006.
5.8.
S&SA-186, % AWD for use with Stability Option I-D for Pilgrim (applicable to SLO).
5.9.
SUDDS/RF 94-42, NEDC-32306P, "Maximum Extended Load Line Limit Analyses",
March 1994.
5.10. SUDDSIRF 88-160, NEDC-31312-P, "ARTS Improvement Program Analysis for Pilgrim Nuclear Power Station", September 4, 1987.
5.11. A22-00109-00 MAPLHGR set down process explanation for Pilgrim, November 2001.
5.12. GNF2NFI, GEH-0000-0085-9069-RO, GNF2 Fuel Design Cycle Independent Analyses for Entergy PNPS, February 2009.
5.13. ER 03110960, Stability I-D implementation.
5.14. PNPS-RPT-03-00001, Rev. 6, "Pilgrim Power To Flow Map Report."(EC27443) 5.15. ECH-NE-11-00013, "Supplemental Reload Licensing Report, Reload 18, Cycle 19."
5.16. PNPS-NE-10-00006, EC23405, Cycle 19 OPL-3, Transient Analyses Inputs.
5.17. ECH-NE-11-00014, 0000-0119-4309-FBIR, Rev.0, Fuel Bundle Information Report, Cycle 19, January 2011 (EC27442).
5.18. SUDDS/RF 02-86, GNF SER issued by NRC approving elimination of Upper Bound PCT limit requirement.
5.19. EC7933 documents OPL-4 & 5 LOCA Inputs.
5.20. NEDO-32465A, Licensing Topical report "Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Application, August 1996.
5.21.
ECH-NE-09-00018, PNPS GNF2 ECCS-LOCA Evaluation.
5.22. RA-ENO-HK1-09-027, Pilgrim Cycle 17 MAPLHGR Extension, March 24, 2009 5.23. NEDE-33270P, GNF2 Advantage Generic Compliance with GESTAR II), Revision 3, March 2010 (This reference is also known as Amendment 22 report for GNF2). (record in eB: RA-ENO-GEN-10-040) 5.24. NEDE-33213, ODYSY Application for Stability Licensing Calculations Including Option I-D and II Long Term Solutions, April 2009 Cycle 19 COLR Revision 32 Page 51 of 51