Update on PWR Fuel Top Nozzle Stress Corrosion Cracking Implications for 10 CFR 72 and 71 Brian Gutherman For 2011 SFST Technical Exchange November 1, 2011

Introduction Certain older Westinghouse fuel assemblies are susceptible to stress corrosion cracking (SCC) at the bulge joints near the top nozzle An event at North Anna in 2001 confirmed that, if severe enough, the SCC could result in the top nozzle separating from the assembly when lifted NRC Information Notice 2002-09 SCC does not affect fuel cladding 2

PWR Fuel Assembly Top Region 3

Top Nozzle Guide Tubes (24)

Bulge Joint Fuel Rods(264)

Center Instrument Tube (1)

Top Grid

Fuel Assembly Bulge Joint Detail 4

=

Background===

Fuel assemblies susceptible to top nozzle SCC were loaded into storage casks at McGuire (and elsewhere) over the years NRC letter to Duke Energy, August 2008:

- Systems containing modified, SSC susceptible fuel assemblies loaded for storage are not transportable until an analysis demonstrating the assemblies meet Part 71 requirements is reviewed and approved by the NRC.

5

RIRP Issue I-10-01 The Duke letter created confusion in the industry among licensees and CoC holders as what it meant for others regarding this fuel

- Industry seeks clarification on whether NRC approval is required under Parts 72 and 71 to store and transport the affected fuel, for:

  • Modified fuel assemblies
  • Unmodified fuel assemblies What regulations and regulatory process(es) apply to making this determination?

6

Initial Industry Proposal Position paper submitted to NRC 8/27/10 Four variants of susceptible fuel assemblies Total of eight variants across 72/71 Proposes position and a basis for if amendments are required in Part 72/71 to store and transport the fuel 7

Variants

1. Unmodified fuel assemblies moved with a standard tool
2. Unmodified fuel assemblies moved with a thimble grip tool
3. Modified assemblies with guide tube anchors (GTAs) or similar device
4. Modified assemblies with instrument tube tie rods (ITTRs) or similar device 8

RIRP Issue Plan

Schedule

- 8/27/10 (A) - Industry position letter to NRC (unmodified and modified assemblies)

- 9/16/10 (A) - Public meeting, NRC requests Industry address Contents issue (modified assemblies)

- 11/9/10 (A) - Industrys Contents white Paper sent to NRC

- 9/22/11 (A) - NRC response to Contents white Paper

- 11/11 (T) - Discuss Industry proposal for unmodified assemblies

- 12/11 (T) - Public meeting to discuss industry proposal for unmodified assemblies and reach consensus on issue closure

Success Criteria

- Decide if storage and/or transport amendments are required for unmodified assemblies (last four variants)

- Agree on technical aspects to address in supporting analyses

- Agree on durable record of issue resolution 9

Resolution of Contents Issue Part 71 and 72

- ITTRs, guide tube anchors, and other similar hardware are contents of a storage cask or transport package

- Cask contents are licensed by the NRC for both Part 72 and 71 Part 72

- Fuel assemblies contain many sub-components not explicitly specified in the CoC or license

- Some are specifically defined and limited as allowable contents because they may significantly influence or change the safety analysis

- Contents that are non-separable constituents of a fuel assembly may not need to be identified in the CoC or license

- Cask or ISFSI FSARs may be able to be amended under 72.48 to list ITTRs, guide tube anchors and similar hardware as non-separable constituents of already approved contents 10

Resolution of Contents Issue (contd)

Part 71

- No 72.48-like change process in Part 71

- Part 71 SAR has a different standing than a Part 72 SAR

- Part 71 CoCs refer to a specific revision of the supporting SAR

- Approved contents, including ITTRs and GTAs need to be specified in the CoC

- CoC holders may want to consider proposing a CoC condition that approves criteria for non-fuel contents that have little or no impact on safety, e.g., foreign material Industry believes issue is resolved for modified assemblies (4 of the 8 variants) 11

Proposed Resolution for Unmodified Assemblies Need to reach agreement on whether prior NRC review and approval is required for storage and transport of unmodified, SCC-susceptible fuel assemblies Industry communicated its position in the 8/27/10 letter, and no new information received to alter the position:

- Fuel classification issue to be implemented by Industry, inspected by NRC

- Use criteria in NUREG-1536, Rev. 1 for storage and ISG-1, Rev. 2 for transportation to classify fuel assembly as damaged or undamaged

- Supporting analyses/evaluations (A/E) required 12

Proposed Path Forward Dec. 2011 Public Meeting to discuss

- Unmodified assemblies and the proposed approach in 8/27/10 letter

- Identify actions need to reach resolution, and update resolution plan Desired final outcome and closure of the RIRP issue

- Durable record to memorialize agreed-upon resolution

  • NEI report with NRC endorsement or Regulatory Guide