Accession No. ML113081792 From:

Feintuch, Karl Sent:

Friday, November 04, 2011 5:23 PM To:

Browning, Tony; Catron, Steve Cc:

Tam, Peter

Subject:

ME7336 - Relief Request - DUANE ARNOLD - Relief Request VR-02 Regarding In-Service Testing of Safety/Relief Valves - acceptance review results

Subject:

ME7336 - Relief Request - DUANE ARNOLD - Relief Request VR-02 Regarding In-Service Testing of Safety/Relief Valves - acceptance review results The NRC staff finds your application for proposed alternative testing for ASME Class 1 Pressure Safety/Relief Valves in a letter dated September 29, 2011 (ADAMS ACCESSION No.:ML112720486) acceptable for review per the guidance in Office of Nuclear Reactor Regulation (NRR) Office Instruction LIC-109.

Karl Feintuch Project Manager Plant Licensing Branch LPL III-1 Office of Nuclear Reactor Regulation USNRC 301-415-3079