November 4, 2011 Dr. Samuel Frimpong, Chair Mining and Nuclear Engineering 226 McNutt Hall Missouri University of Science and Technology Rolla, MO 65409-0450
SUBJECT:
EXAMINATION REPORT NO. 50-123/OL-12-01, MISSOURI UNIVERSITY OF SCIENCE AND TECHNOLOGY
Dear Dr. Frimpong:
During the week of October 17, 2011, the U.S. Nuclear Regulatory Commission (NRC) administered operator licensing examinations at your Missouri University of Science and Technology Reactor. The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed at the conclusion of the examination with those members of your staff identified in the enclosed report.
In accordance with Title 10, Section 2.390 of the Code of Federal Regulations, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. If you have any questions concerning this examination, please contact Mr. John T. Nguyen at (301) 415-4007 or via internet e-mail John.Nguyen@nrc.gov.
Sincerely,
/RA/
Johnny H. Eads, Jr., Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-123
Enclosures:
- 1. Examination Report No. 50-123/OL-12-01
- 2. Written examination with facility comments cc: Bill Bonzer, Reactor Manager cc: w/o enclosures: See next page
Dr. Samuel Frimpong, Chair November 4, 2011 Mining and Nuclear Engineering 226 McNutt Hall Missouri University of Science and Technology Rolla, MO 65409-0450
SUBJECT:
EXAMINATION REPORT NO. 50-123/OL-12-01, MISSOURI UNIVERSITY OF SCIENCE AND TECHNOLOGY
Dear Dr. Frimpong:
During the week of October 17, 2011, the U.S. Nuclear Regulatory Commission (NRC) administered operator licensing examinations at your Missouri University of Science and Technology Reactor. The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed at the conclusion of the examination with those members of your staff identified in the enclosed report.
In accordance with Title 10, Section 2.390 of the Code of Federal Regulations, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. If you have any questions concerning this examination, please contact Mr. John T. Nguyen at (301) 415-4007 or via internet e-mail John.Nguyen@nrc.gov.
Sincerely,
/RA/
Johnny H. Eads, Jr., Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-123
Enclosures:
- 1. Examination Report No. 50-123/OL-12-01
- 2. Written examination with facility comments cc: Bill Bonzer, Reactor Manager cc: w/o enclosures: See next page DISTRIBUTION w/ encls.:
PUBLIC PROB r/f JEads Facility File CRevelle (O07-F8)
ADAMS ACCESSION #: ML113040172 OFFICE PROB:CE IOLB:LA PROB:BC NAME JNguyen CRevelle JEads DATE 10/31/2011 11/03/2011 11/042011 OFFICIAL RECORD COPY
University of Missouri - Rolla Docket No. 50-123 cc:
Homeland Security Coordinator Missouri Office of Homeland Security P.O. Box 749 Jefferson City, MO 65102 Planner, Dept of Health and Senior Services Section for Environmental Public Health 930 Wildwood Drive, P.O. Box 570 Jefferson City, MO 65102-0570 Deputy Director for Policy Department of Natural Resources 1101 Riverside Drive Fourth Floor East Jefferson City, MO 65101 A-95 Coordinator Division of Planning Office of Administration P.O. Box 809 State Capitol Building Jefferson City, MO 65101 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
ENCLOSURE 1 U. S. NUCLEAR REGULATORY COMMISSION OPERATOR LICENSING INITIAL EXAMINATION REPORT REPORT NO.:
50-123/OL-12-01 FACILITY DOCKET NO.:
50-123 FACILITY LICENSE NO.:
R-79 FACILITY:
Missouri University of Science and Technology SUBMITTED BY:
_______________/RA/_______________ 10/31/2011 John T. Nguyen, Chief Examiner Date
SUMMARY
During the week of October 17, 2011, the NRC administered operator licensing examinations to eight license candidates including four Reactor Operator (RO), two Senior Reactor Operator -
Upgrade (SRO-U), and two Senior Reactor Operator - Instant (SRO-I) license candidates. All license candidates passed all applicable portions of their examinations.
REPORT DETAILS
- 1.
Examiner: John T. Nguyen, Chief Examiner
- 2.
Results:
RO PASS/FAIL SRO PASS/FAIL TOTAL PASS/FAIL Written 4/0 2/0 6/0 Operating Tests 4/0 4/0 8/0 Overall 4/0 4/0 8/0
- 3.
Exit Meeting:
William Bonzer, MSTR, Reactor Manager Craig Reisner, MSTR, Reactor Training Coordinator John Nguyen, NRC, Chief Examiner Patrick Isaac, NRC, Examiner The NRC examiners thanked the facility for their support in the administration of the examinations. The NRC examiners noted that all the license candidates were well prepared for the examinations. The facility licensee had no comments on the written examination except the comments presented during the exit meeting, which have been incorporated into the examination included as Enclosure 2 to this report.
ENCLOSURE 2 U. S. NUCLEAR REGULATORY COMMISSION NON-POWER REACTOR LICENSE EXAMINATION FACILITY:
Missouri University of Science and Technology (Rolla)
REACTOR TYPE:
MTR DATE ADMINISTERED:
10/17/2011 CANDIDATE:
INSTRUCTIONS TO CANDIDATE:
Answers are to be written on the Answer sheet provided. Attach all Answer sheets to the examination. Point values are indicated in parentheses for each question. A 70% in each category is required to pass the examination. Examinations will be picked up three (3) hours after the examination starts.
% OF CATEGORY % OF CANDIDATE'S CATEGORY VALUE TOTAL SCORE VALUE CATEGORY 16.00 33.3 A. REACTOR THEORY, THERMODYNAMICS AND FACILITY OPERATING CHARACTERISTICS 16.00 33.3 B. NORMAL AND EMERGENCY OPERATING PROCEDURES AND RADIOLOGICAL CONTROLS 16.00 33.3 C. FACILITY AND RADIATION MONITORING SYSTEMS 48.00 % TOTALS FINAL GRADE All work done on this examination is my own. I have neither given nor received aid.
Candidate's Signature
A. RX THEORY, THERMO & FAC OP CHARS A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
A01 a b c d ___
A02 a b c d ___
A03 a b c d ___
A04 a b c d ___
A05 a b c d ___
A06 a b c d ___
A07 a b c d ___
A08 a b c d ___
A09 a b c d ___
A10 a b c d ___
A11 a b c d ___
A12 a b c d ___
A13 a b c d ___
A14 a b c d ___
A15 a b c d ___
A16 a b c d ___
(***** END OF CATEGORY A *****)
B. NORMAL/EMERG PROCEDURES & RAD CON A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
B01 a b c d ___
B02 a b c d ___
B03 a ___ b ___ c ___ d ___
B04 a b c d ___
B05 a b c d ___
B06 a b c d ___
B07 a b c d ___
B08 a b c d ___
B09 a b c d ___
B10 a b c d ___
B11 a b c d ___
B12 a b c d ___
B13 a b c d ___
B14 a b c d ___
B15 a b c d ___
B16 a b c d ___
(***** END OF CATEGORY B *****)
C. PLANT AND RAD MONITORING SYSTEMS A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
C01 a b c d ___
C02 a b c d ___
C03 a b c d ___
C04 a b c d ___
C05 a b c d ___
C06 a b c d ___
C07 a b c d ___
C08 a b c d ___
C09 a b c d ___
C10 a b c d ___
C11 a b c d ___
C12 a ___ b ___ c ___ d ___
C13 a b c d ___
C14 a b c d ___
C15 a b c d ___
(***** END OF CATEGORY C *****)
(********** END OF EXAMINATION **********)
NRC RULES AND GUIDELINES FOR LICENSE EXAMINATIONS During the administration of this examination the following rules apply:
- 1.
Cheating on the examination means an automatic denial of your application and could result in more severe penalties.
- 2.
After the examination has been completed, you must sign the statement on the cover sheet indicating that the work is your own and you have neither received nor given assistance in completing the examination. This must be done after you complete the examination.
- 3.
Restroom trips are to be limited and only one candidate at a time may leave. You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.
- 4.
Use black ink or dark pencil only to facilitate legible reproductions.
- 5.
Print your name in the blank provided in the upper right-hand corner of the examination cover sheet and each Answer sheet.
- 6.
Mark your Answers on the Answer sheet provided. USE ONLY THE PAPER PROVIDED AND DO NOT WRITE ON THE BACK SIDE OF THE PAGE.
- 7.
The point value for each question is indicated in [brackets] after the question.
- 8.
If the intent of a question is unclear, ask questions of the examiner only.
- 9.
When turning in your examination, assemble the completed examination with examination questions, examination aids and Answer sheets. In addition turn in all scrap paper.
- 10.
Ensure all information you wish to have evaluated as part of your Answer is on your Answer sheet. Scrap paper will be disposed of immediately following the examination.
- 11.
To pass the examination you must achieve a grade of 70 percent or greater in each category.
- 12.
There is a time limit of three (3) hours for completion of the examination.
EQUATION SHEET C C Q = m cp T C C Q = m h SCR = S/(1-Keff)
C Q = UA T CR1 (1-Keff)1 = CR2 (1-Keff)2 26.06 (eff)
(1-Keff)0 SUR =
M =
( - )
(1-Keff)1 SUR = 26.06/
M = 1/(1-Keff) = CR1/CR0 P = P0 10SUR(t)
SDM = (1-Keff)/Keff P = P0 e(t/)
I = Io e-ux (1-)
P = Po R* = 1 x 10-4 seconds
= (R*/) + [(-)/eff]
= R*/(-)
= (Keff-1)/Keff R = 6 C E n
Keff/Keff 0.693 T1/2
= 0.007 DR1D1 2 = DR2D2 2
DR = DRoe-t Cp (H20) = 0.146 kw P = S / (1 - Keff) gpm @ EF eff = 0.1/sec 1 Curie = 3.7x1010 dps 1 kg = 2.21 lbm 1 hp = 2.54x103 BTU/hr 1 Mw = 3.41x106 BTU/hr 1 BTU = 778 ft-lbf EF = 9/5EC + 32 931 Mev = 1 amu EC = 5/9 (EF - 32)
Section A: Reactor Theory, Thermo, and Fac. Operating Characteristics QUESTION A.01
[1.0 point]
Which ONE of the following will be the resulting stable reactor period when a 0.175 % k/k reactivity insertion is made into an exactly critical reactor core? Given =0.007
- a.
18 seconds
- b.
30 seconds
- c.
38 seconds
- d.
50 seconds QUESTION A.02
[1.0 point]
Which ONE of the following isotopes has the highest thermal neutron cross section?
- a.
B-10
- b.
Sm-149
- c.
Xe-135
- d.
U-235 QUESTION A.03
[1.0 point]
Which ONE of the following statements best describes on how moderator temperature affects the core operating characteristics?
- a.
Increase in moderator temperature will increase the neutron multiplication factor due to the resonance escape probability increase.
- b.
Increase in moderator temperature will increase the neutron multiplication factor due to the fast non leakage probability decrease.
- c.
Increase in moderator temperature will decrease the neutron multiplication factor due to the reproduction factor increase.
- d.
Increase in moderator temperature will decrease the neutron multiplication factor due to the resonance escape probability decrease.
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.04
[1.0 point]
The reactor is operating at 100 KW. The reactor operator withdraws the control rod allowing power to increase. The operator then inserts the same rod to its original position, decreasing power. In comparison to the rod withdrawal, the rod insertion will result in:
- a.
a slower period due to long lived delayed neutron precursors.
- b.
a faster period due to long lived delayed neutron precursors.
- c.
the same period due to equal amounts of reactivity being added.
- d.
the same period due to equal reactivity rates from the rod.
QUESTION A.05
[1.0 point]
Given a source strength of 100 neutrons per second (N/sec) and a multiplication factor of 0.9, which ONE of the following is the expected stable neutron count rate?
- a.
900 N/sec
- b.
1000 N/sec
- c.
2000 N/sec
- d.
2500 N/sec QUESTION A.06
[1.0 point] Key answer changes from a to b. Corrected typographical error.
Given a reactor period of 32 seconds, approximately how long will it take for power to triple?
- a.
22 seconds
- b.
35 seconds
- c.
46 seconds
- d.
64 seconds
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.07 [1.0 point]
Keff is K4 times Y
- a.
the reproduction factor ()
- b.
the resonance escape probability (p)
- c.
the fast fission factor ()
- d.
the total non-leakage probability (f H th)
QUESTION A.08 [1.0 point]
Xenon-135 (Xe135) is produced in the reactor by two methods. One is directly from fission; the other is indirectly from the decay of :
- a.
Xe136
- b.
Sm136
- c.
Cs135
- d.
I135 QUESTION A.09 [1.0 point]
Which one of the following is the principal source of heat in the reactor after a shutdown from extended operation at 100 KW?
- a.
Production of delayed neutrons
- b.
Subcritical reaction of photo-neutrons
- c.
Spontaneous fission of U238
- d.
Decay of fission fragments
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.10
[1.0 point]
Which ONE of the following statements correctly describes thermal neutrons?
- a.
A neutron that experiences a linear decrease in energy as the temperature of the moderator increases.
- b.
A neutron at resonant epithermal energy levels that causes fissions to occur in U-238.
- c.
A neutron that experiences an increase in energy levels after collisions with larger atoms of the moderator.
- d.
A neutron that experiences no net change in energy after several collisions with atoms of the moderator.
QUESTION A.11 [1.0 point]
A reactor with Keff = 0.5 contributes 1000 neutrons in the first generation. Changing from the first generation to the SECOND generation, how many neutrons are there in the second generation?
- a.
1250
- b.
1500
- c.
1750
- d.
2000 QUESTION A.12
[1.0 point]
In a subcritical reactor, Keff is increased from 0.861 to 0.946. Which ONE of the following is the amount of reactivity that was added to the core?
- a.
0.054 delta-K/K
- b.
0.104 delta-K/K
- c.
0.125 delta-K/K
- d.
0.161 delta-K/K
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.13
[1.0 point]
The reactor is shutdown with the count rate of 100 counts per second (cps) and Keff of 0.952.
The Shim rods are withdrawn until the count rate is a steady 2000 cps. What is the new value of Keff ?
- a.
0.952
- b.
0.973
- c.
0.998
- d.
1.020 QUESTION A.14
[1.0 point]
Delayed neutrons comprise approximately what percent of all neutrons produced in the reactor?
- a.
0.65%
- b.
1.3%
- c.
6.5%
- d.
20%
QUESTION A.15
[1.0 point]
Which ONE of the following is accurate concerning control rod worth?
- a.
Doubling the poison content of a rod doubles its worth.
- b.
Rod worth increases as reactor coolant temperature decreases.
- c.
Rod worth increases as reactor coolant temperature increases.
- d.
A rod located in the edge of the core is worth more than one located near the center of the core.
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.16
[1.0 point]
The reactor is on a CONSTANT positive period. Which ONE of the following power changes will take the longest time to complete?
- a.
5%, from 95% to 100%
- b.
10%, from 80% to 90%
- c.
15%, from 15% to 30%
- d.
20%, from 60% to 80%
(***** END OF CATEGORY A *****)
Section B Normal/Emergency Procedures and Radiological Controls QUESTION B.01 [1.0 point]
Per SOP 101, the trainee may operate the reactor controls under the direct supervision of a Senior Reactor Operator when the excess reactivity is greater than ______ % k/k and less than ____ % k/k
- a.
0.2, 0.7
- b.
0.5, 0.7
- c.
0.7, 1.5
- d.
0.7, 2.0 QUESTION B.02 [1.0 point]
A radiation survey of an area reveals a general radiation reading of 1 mrem/hr. However, there is a small section of pipe which reads 10 mrem/hr at one (1) meter. Assuming that the pipe is a point source, which ONE of the following defines the posting requirements for the area in accordance with 10CFR Part 20?
- a.
Restricted Area
- b.
Radiation Area
- c.
- d.
Grave Danger, Very High Radiation Area QUESTION B.03 [1.0 point, 0.25 each]
Common radioisotopes associated with research reactors are N16, Ar4l, H3 and Na24. The half-life for each is (seconds (sec), minutes (min) hours (hr) or years (yr)).
- a.
N16 is 7.0 _____.
- b.
Ar41 is 1.9 _____.
- c.
H3 is 12.0 _____.
- d.
Na24 is 15.0 _____.
Section B Normal/Emergency Procedures and Radiological Controls QUESTION B.04 [1.0 point]
The drop-time of each of the three shim rods shall be measured:
- a.
monthly
- b.
quarterly
- c.
semi-annually
- d.
annually QUESTION B.05 [1.0 point]
Which ONE of the following definitions is the Total Effective Dose Equivalent (TEDE) as specified in 10 CFR Part 20?
- a.
The sum of thyroid dose and external dose.
- b.
The sum of the external deep dose and the organ dose.
- c.
The sum of the deep dose equivalent and the committed effective dose equivalent.
- d.
The dose that your whole body is received from the source, but excluded from the deep dose.
QUESTION B.06 [1.0 point]
A small radioactive source is to be stored in the reactor building. The source is estimated to contain 4 curies and emit a 1.17 Mev gamma. Assuming no shielding was to be used, a Radiation Area barrier would have to be erected from the source at a distance of approximately:
- a.
28 feet
- b.
32 feet
- c.
75 feet
- d.
87 feet
Section C Facility and Radiation Monitoring Systems QUESTION B.07 [1.0 point]
What is the maximum allowable dose which the Emergency Director can authorize for a volunteer to receive to save the life of someone injured and trapped in the reactor compartment?
- a.
125 Rem
- b.
100 Rem
- c.
75 Rem
- d.
50 Rem QUESTION B.08 [1.0 point]
Reactor Operator works a standard forty (40) hour work week. His duties require him to work in a radiation area for (5) hours a day. The dose rate in the area is 50 mR/hour. Which ONE of the following is the MAXIMUM number of days Reactor Operator may perform his duties WITHOUT exceeding 10 CFR 20 limits?
- a.
15 days
- b.
20 days
- c.
40 days
- d.
50 days QUESTION B.09 [1.0 point]
Which ONE of the following materials shall NOT be irradiated at MSTR?
- a.
A corrosive material
- b.
10 mg of explosive material
- c.
0.2 % k/k worth of unsecured experiment
- d.
Fueled experiment which would generate a power of 30 W
Section C Facility and Radiation Monitoring Systems QUESTION B.10 [1.0 point]
During a reactor startup, the reactor operator calculates that the maximum excess reactivity for reference core conditions is 1.6 %k/k. For this excess reactivity, which ONE of the following is the best action?
- a.
Continue to operate because the excess reactivity is within TS limit.
- b.
Increase power to 20 kW and verify the excess reactivity again.
- c.
Shutdown the reactor; immediately report the result to Reactor Manager due to excess being above TS limit.
d Continue operation, but immediately report the result to the Senior Reactor Operator since the excess reactivity is about exceeding TS limit.
QUESTION B.11 [1.0 point]
A sheet of two-inch lead reduces the gamma exposure in a beam of radiation from 800 mR/hr to 400 mR/hr. If you add additional 2 sheets (total of six inches of lead) what will be the new radiation level? (Assume all reading is the same distance from the source.)
- a.
50 mR/hr
- b.
100 mR/hr
- c.
175 mR/hr
- d.
200 mR/hr QUESTION B.12 [1.0 point]
According to Technical Specification 3.3 The minimum temperature of the reactor pool should be no less than _________ when the reactor is operated.
- a.
10.0 °C (50 °F)
- b.
12.8 °C (55 °F)
- c.
15.5 °C (60 °F)
- d.
18.3 °C (65 °F)
Section C Facility and Radiation Monitoring Systems QUESTION B.13 [1.0 point]
During a normal reactor operation, a senior reactor operator (SRO) becomes ill and is taken to the hospital. Only a reactor operator (RO) and a knowledgeable student remain in the facility.
Per Operation Procedure SOP101, reactor operation:
- a.
must be discontinued because reactor operation needs 2 licensed operators.
- b.
must be discontinued because reactor operation needs a licensed SRO.
- c.
may continue until a replacement SRO can arrive at the facility within 60 minutes.
- d.
may continue since the RO can monitor the console while the student can carry out prescribed written instructions.
QUESTION B.14 [1.0 point]
Determine its DECAY CONSTANT (), when a radioactive material is DECAYING at a rate of 30% per hour.
- a.
0.155
- b.
0.236
- c.
0.357
- d.
1.202 QUESTION B.15 [1.0 point]
Which ONE of the following is the large contributor to Ar-41 production?
- a.
Neutron interaction with the hydrogen in the reactor pool water
- b.
Gamma interaction with the oxygen in the reactor pool water
- c.
Beta interaction with the Nitrogen in the reactor pool water
- d.
Neutron interaction with dissolved air in the reactor pool water
Section C Facility and Radiation Monitoring Systems QUESTION B.16 [1.0 point]
Which ONE of the following conditions requires the reactor operator shutdown the reactor operation?
- a.
The inlet temperature reaches 65 °F.
- b.
The Safety Channel # 2 alarms due to an internal faulty relay.
- c.
Reactor power increases from 95% to 97% while pool is filling.
- d.
Reactor power decreases from 55% to 50% when a rabbit is removed.
(***** END OF CATEGORY B *****)
Section C Facility and Radiation Monitoring Systems QUESTION C.01 [1.0 point]
Which ONE of the following is the initial position of the SHIM rods that the reactor operator needs to withdraw during a startup to lower power?
- a.
6 inches
- b.
10 inches
- c.
12 inches
- d.
16 inches QUESTION C.02 [1.0 point]
To reduce radiological activity within the demineralizer tank, the reactor operator needs to:
- a.
encapsulate the corrosive material.
- b.
change the resin in the demineralizer tank by quarterly.
- c.
turn on the reactor pools water pump after a high power run is performed.
- d.
turn off the reactor pools water pump after a high power run is performed.
QUESTION C.03 [1.0 point]
For a shim-safety rod, the "withdraw limit" light is ON, the "insert limit" light is OFF, and the "contact" light is ON. This means that:
- a.
The rod and drive are not in contact, the rod is full in and the drive is full out.
- b.
The rod and drive are not in contact, the rod and drive are both full in.
- c.
The rod and drive are in contact, the rod and drive are both full in.
- d.
The rod and drive are in contact, the drive and rod are full out.
Section C Facility and Radiation Monitoring Systems QUESTION C.04 [1.0 point]
A signal for the Period < 5 Sec Scram comes from the:
- a.
Startup channel
- b.
Log/Linear channel
- c.
Linear channel
- d.
Safety channel QUESTION C.05 [1.0 point]
Which ONE of the following events will cause the audio/visual (RED) alarms?
- a.
Log N =125 %
- b.
Recorder off
- c.
Significant Loss of coolant
- d.
Safety Channel # 2 = 130%
QUESTION C.06 [1.0 point]
Which ONE of the following conditions does NOT allow the reactor operator changing the reactor operation from a steady-state mode to an AUTOMATIC mode?
- a.
Two of shim rods are fully up.
- b.
One of shim rods is fully down.
- c.
The regulating rod position indicates 12 inches of withdrawal.
- d.
The demand power sets at 150 kW, and the actual power indicates at 135 kW.
Section C Facility and Radiation Monitoring Systems QUESTION C.07 [1.0 point]
Which ONE of the following describes the status of reactor coolant systems when the reactor is filled with demineralized water?
- a.
Recirculation line valve: CLOSE. Pump discharge line valve:CLOSE. Pump suction line valve: OPEN
- b.
Recirculation line valve: CLOSE. Pump discharge line valve:OPEN. Pump suction line valve: CLOSE
- c.
Recirculation line valve: OPEN. Pump discharge line valve:CLOSE. Pump suction line valve: OPEN
- d.
Recirculation line valve: OPEN. Pump discharge line valve:CLOSE. Pump suction line valve: CLOSE QUESTION C.08 [1.0 point] Change from Stack Particulate Monitor to Continuous Air Monitor (CAM). The facility does not have the Stack Particulate Monitor When a failure of a fuel experiment occurs, the Stack Particulate Monitor Continuous Air Monitor (CAM) will alarm due to the release of:
- a.
- b.
Ar-41
- c.
Na-24
- d.
Xe-135 QUESTION C.09 [1 point] Change from Stack Particulate Monitor to Continuous Air Monitor (CAM). The facility does not have the Stack Particulate Monitor WHICH ONE of the following is true statement regarding detector requirement to measure N16 release to the environment?
- a.
NONE, N16 has too short a half-life to require environmental monitoring.
- b.
Stack Particulate Monitor Continuous Air Monitor (CAM)
- c.
Stack Gas Monitor
- d.
Bridge Area Monitor
Section C Facility and Radiation Monitoring Systems QUESTION C.10 [1.0 point]
Which ONE of the following would indicate a clog in the demineralizer tank?
- a.
High radiation level at pool surface
- b.
High flow rate through demineralizer
- c.
High temperature in demineralizer
- d.
High pressure upstream of demineralizer QUESTION C.11 [1.0 point]
Which ONE of the following best describes on how the Uncompensated Ion Chamber (UIC) and Compensated Ion Chamber (CIC) operate?
- a.
The CIC has two chambers, both can sense gamma rays but only one is coated with boron-10 for (n,) reaction; whereas the UIC has only one chamber coated with boron-10 for (n,) reaction.
- b.
The CIC has two chambers, one is coated with U-235 for fission reaction and the other is coated with boron-10 for (n,) reaction; whereas the UIC has only one chamber coated with U-235 for fission reaction.
- c.
The CIC has only one chamber coated with boron-10 for (n,) reaction; whereas the UIC has two chambers, one is coated with U-235 for fission reaction and the other is coated with boron-10 for (n,) reaction.
- d.
The CIC has only one chamber coated with U-235 for fission reaction, whereas the UIC has two chambers, both can sense gamma rays but only one is coated with boron-10 for (n,) reaction.
QUESTION C.12 [2.0 points, 0.5 each]
Match the input signals listed in column A with their respective responses listed in column B.
(Items in column B is to be used more than once or not at all.)
Column A Column B
- a.
Core inlet water temperature = 60 °C
- 1.
Alarm only
- b.
Interlock by pass
- 2.
Alarm and rod prohibit
- c.
Low CIC voltage
- 3.
Alarm and reactor scram
- d.
Count rate= 2 cps
- 4.
Alarm and rod rundown
Section C Facility and Radiation Monitoring Systems QUESTION C.13 [1.0 point]
Which ONE of the following is the Safety Limit (LS) for the MSTR?
- a.
The cladding temperature must not exceed 510 °C.
- b.
The cladding temperature must not exceed 527 °C.
- c.
The thermal power shall not exceed 240 kW (120% of full power).
- d.
The thermal power shall not exceed 300 kW (150% of full power).
QUESTION C.14 [1.0 point]
Which ONE of the following is the method used to get rid of radioactive liquid waste?
Radioactive liquid waste is
- a.
tested for 10CFR20 limits, then pumped to the storage tank.
- b.
put liquid waste through evaporators, collect them in solid form after passing through air filters.
- c.
diluted with chemical to meet 10CFR20 limits, then pumped to the sanitary sewer system.
- d.
held for decay of short lived isotopes then sampled for 10CFR20 limits and if satisfactory, pumped to the sanitary sewer system.
QUESTION C.15 [1.0 point]
Which ONE of the following experimental facilities will have highest ratio between thermal neutron flux and fast neutron flux (flux in thermal/flux in fast) during full power operation?
- a.
Thermal Column in T mode
- b.
Sample Rotor Assembly
- c.
Core Access Element
- d.
Beam Tube
(***** END OF CATEGORY C *****)
(***** END OF EXAMINATION *****)
Section A L Theory, Thermo & Fac. Operating Characteristics A.01 Answer:
b T = (-)/
T = (.0070 -.00175)/0.1 x 0.00175 = 30 seconds A.02 Answer:
c
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Table2.5, page 2-59.
A.03 Answer:
d
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Sec 3.3.1 A.04 Answer:
a
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Sec 3.2.2 A.05 Answer:
b
Reference:
CR = S/(1-K) CR = 100/(1 -.9) = 1000 A.06 Answer:
a b
Corrected typographical error.
Reference:
P=Poet/ 3=1* et/32 t = 32 sec*ln(3) = 35.2 sec A.07 Answer:
d
Reference:
DOE Handbook Vol 2, L Theory (Nuclear Parameters), E.O. 1.1 a&b, pg. 9 A.08 Answer:
d
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1988,
§§ 8.1 8.4, pp. 8-3 8-14.
A.09 Answer:
d
Reference:
DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory Volume 1, Module 1, Enabling Objective 4.9, p. 61.
A.10 Answer:
d
Reference:
NRC Standard Question A.11 Answer:
b
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, § 5.3, p. 5.6 2-nd generation=n + K*n=1000+500=1500 neutrons
Section A L Theory, Thermo & Fac. Operating Characteristics A.12 Answer:
b
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 3.3.3, page 3-21.
At k=0.861; = Keff/Keff or = Keff-1/Keff = -0.139/0.861 =-0.161. At k=0.946, =-
0.054/0.946 = -0.0571. The difference between is the answer,i.e. -0.0571-(-0.161)=0.104 A.13 Answer:
c
Reference:
Count1*(1-Keff1) = Count2*(1-Keff2)
Count1*(1-0.952) = Count2*(1-Keff2) 100*(1-0.952) = 2000(1-Keff2); Keff2 = 0.998 A.14 Answer:
- a.
Reference:
DOE Fundamentals Handbook, Nuclear Physics and Reactor Theory, Volume 2 A.15 Answer:
c
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, ' 3.3.2, p. 3-18.
A.16 Answer:
c
Reference:
Time is related to ratio of final power to initial power. 2:1 is the largest ratio.
Section B Normal/Emergency Procedures and Radiological Controls B.01 Answer:
c
Reference:
SOP 101, Sec B.3.b.ii B.02 Answer:
c
Reference:
10 mrem/hr at 1 meter (100 cm.) = 111.1mrem/hr at 30 cm.
B.03 Answer:
- a. = sec,
- b. = hr;
- c. = yr;
- d. = hr;
Reference:
NRC bank question B.04 Answer:
c
Reference:
TS 4.2.1 B.05 Answer:
c
Reference:
B.06 Answer:
c
Reference:
at 1 foot DR= 6CEN = 6*4*1.17*1, DR=28.1 Rem/hr at 1 foot.
Radiation Area barrier = 0.005 Rem/hr Distance for a dose at 0.005 Rem/hr will be: Dr1D1 2 = Dr2D2 2 28.1= 0.005 x2, x2 = 5616, x = 74.9 ft B.07 Answer:
c
Reference:
MST Emergency Plan 7.4.6 B.08 Answer:
b
Reference:
10CFR20.1201(a)(1) [5000 mr x 1 hr x day = 20 days 50 mr 5 hr B.09 Answer:
d
Reference:
TS 3.7.1 & 3.7.2 B.10 Answer:
c
Reference:
TS 3.1 B.11 Answer:
b
Reference:
2 inches equal a half-thickness. Adding 4 inches (in total of six inches) results in a total of three half-thicknesses. (800) x (1/2)3 = 800*0.125 = 100 mR/hr B.12 Answer:
c
Reference:
Section B Normal/Emergency Procedures and Radiological Controls B.13 Answer:
d
Reference:
SOP 101 B.14 Answer:
c
Reference:
DR = DR*e -t 30% is decayed, so 70% is still there 70% =100%* e -(1hr)
Ln(70/100) = -*1 -->=0.357 B.15 Answer:
d
Reference:
NRC Standard Question B.16 Answer:
b
Reference:
Section C Facility and Radiation Monitoring Systems C.01 Answer:
a
Reference:
SOP 103 C.02 Answer:
d
Reference:
SOP 101, Sec B.5 C.03 Answer:
d
Reference:
SAR 7.2.2.6 C.04 Answer:
b
Reference:
SAR 7.2.2 C.05 Answer:
c
Reference:
SAR 7.2.2 C.06 Answer:
d
Reference:
SAR 7.2.2.6 page 7-8, the servo system interlock (>2% of set point)
C.07 Answer:
a
Reference:
SOP 301 C.08 Answer:
d
Reference:
SAR, Table 13.1 C.09 Answer:
a
Reference:
Standard NRC Question.
C.10 Answer:
d
Reference:
Standard NRC question C.11 Answer:
a
Reference:
NRC Standard Question C.12 Answer:
a(2) b(1) c(4) d(2)
Reference:
SAR 7.2 C.13 Answer:
a
Reference:
Section C Facility and Radiation Monitoring Systems C.14 Answer:
d
Reference:
SAR 11.1.1 C.15 Answer:
a
Reference:
SAR 10.2