ET 11-0008, (WCGS) - Results of the Seventeenth Steam Generator Tube Inservice Inspection
| ML11298A261 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 10/19/2011 |
| From: | Clemens R Wolf Creek |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| ET 11-0008 | |
| Download: ML11298A261 (127) | |
Text
WPLF CREP
'NUCLEAR OPERATING CORPORATION Richard P. Clemens Vice President Engineering October 19, 2011 ET 11-0008 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
Subject:
Docket No. 50-482: Results of the Seventeenth Steam Generator Tube Inservice Inspection Gentlemen:
The Attachment, the Steam Generator Tube Inspection Report, is being submitted in accordance with Wolf Creek Generating Station (WCGS) Technical Specification (TS) 5.6.10, "Steam Generator Tube Inspection Report."
This report provides the results of WCGS's seventeenth steam generator (SG) tube inservice inspection.
The Steam Generator Tube Inspection Report includes the following:
- a. The scope of inspections performed on each SG;
- b. Active degradation mechanisms found;
- c. Nondestructive examination techniques utilized for each degradation mechanism;
- d. Location, orientation (if linear), and measured sizes (if available) of service induced indications;
- e. Number of tubes plugged during the inspection outage for each active degradation mechanism;
- f.
Total number and percentage of tubes plugged to date;
- g. The results of condition monitoring, including the results of tube pulls and in-situ testing; The following items are also included in accordance with the One-time Alternate Repair Criteria, H*, which was approved by the Nuclear Regulatory Commission (NRC) to support WCGS's Refueling Outage 18 and the subsequent operating cycle:
- h.
Following completion of an inspection performed in Refueling Outage 18 (and any inspections performed in the subsequent operating cycle) the primary to secondary LEAKAGE rate observed in each SG (if it is not practical to assign the LEAKAGE to an individual SG, the entire primary to secondary LEAKAGE should be conservatively assumed to be from one SG) during the cycle preceding the inspection which is the subject of the report;
- i. Following completion of an inspection performed in Refueling Outage 18 (and any inspections performed in the subsequent operating cycle) the calculated accident induced leakage rate from the portion of the tubes below 15.2 inches from the top of the tubesheet for the most limiting accident in the most limiting SG.
In addition, if the calculated accident induced leakage rate from the most limiting accident is less than 2.50 times the maximum operational primary to secondary leak rate, the report should describe how it was determined; and P.O. Box 411 / Burlington, KS 66839 / Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HCNET
ET 11-0008 Page 2 of 2
- j.
Following completion of an inspection performed in Refueling Outage 18 (and any inspections performed in the subsequent operating cycle) the results of monitoring for the tube axial displacement (slippage).
If slippage is discovered, the implications of discovery and corrective action shall be provided.
Enclosures 1, 2, 3 and 4 contain all service-induced indications identified in SGs A, B, C and D during WCGS's Refueling Outage 18.
No commitments are contained in this correspondence.
If you have any questions concerning this matter, please contact me at (620) 364-4084, or Mr.
Gautam Sen at (620) 364-4175.
Sincer P. Clemens RPC/rlt Attachment : : : :
Steam Generator A Service-Induced Indications Steam Generator B Service-Induced Indications Steam Generator C Service-Induced Indications Steam Generator D Service-Induced Indications cc:
E. E. Collins (NRC), w/a, w/e J. R. Hall (NRC), w/a, w/e G. B. Miller (NRC), w/a, w/e Senior Resident Inspector (NRC), w/a, w/e
Attachment to ET 11-0008 Page 1 of 8 STEAM GENERATOR TUBE INSPECTION REPORT This report is being submitted pursuant to Technical Specification 5.6.10, "Steam Generator Tube Inspection Report," to report the results of the seventeenth steam generator (SG) tube inservice inspection.
S ummary The seventeenth SG tube inservice inspection was completed by Westinghouse Electric Corporation on April 12, 2011, during Refueling Outage 18 (RF18). Initial entry into MODE 4 was achieved on May 24, 2011.
Refueling Outage 18 was the third inspection of the third inspection interval (60 Effective Full Power Months (EFPMs)). At the Start of Refueling Outage 18 the SGs had operated for a total of 262.08 EFPMs (21.84 Effective Full Power Years (EFPYs)).
Permanent approval of an alternate repair criteria, H*, for indications within the tubesheet (TS) could not be achieved prior to Refueling Outage 18. As a result, a One-time Alternate Repair Criteria, H*, was approved by the Nuclear Regulatory commission (NRC) which revised Technical Specification 5.5.9, "Steam Generator (SG) Program" and Technical Specification 5.6.10, "Steam Generator Tube Inspection Report" for Wolf Creek Generating Station's (WCGS's) Refueling Outage 18 and the subsequent operating cycle. The following alternate tube repair criteria shall be applied as an alternative to the 40% through wall depth (TWD)-
based criteria:
H* is the distance from the top of the tubesheet (TTS) into the TS expansion region that tubes must be free of stress corrosion flaws to assure that the tubes do not pull out of the TS under the limiting loads with appropriate factors of safety. For WCGS, the H* distance is 15.2 inches.
All defects below the H* distance are not relevant to the integrity of the tube. Therefore inspection and repair below the H* distance is not required by the technical specification. For Refueling Outage 18 and the subsequent operating cycle, tubes with service-induced flaws located greater than 15.2 inches below the TTS do not require plugging. Tubes with service-induced flaws located in the portion of the tube from the TTS to 15.2 inches below the TTS shall be plugged upon detection.
No corrosion related tube degradation mechanisms were detected in any region of the SGs.
Wear at anti-vibration bar (AVB) intersections; wear at the flow distribution baffle; and wear due to foreign objects continue to be monitored.
Secondary side maintenance and inspections were also performed, The condition of the SGs has met all industry and regulatory structural and leakage integrity requirements.
Section 1 of this report describes the scope of inspections performed, including the nondestructive examination techniques utilized for each degradation mechanism.
Section 2 contains the location, orientation (if linear), and measured sizes (if available) of service induced indications.
Attachment to ET 11-0008 Page 2 of 8 STEAM GENERATOR TUBE INSPECTION REPORT Section 3 contains the inspection results, which include:
- a. Active degradation mechanisms found;
- b. Number of tubes plugged during the inspection outage for each active degradation mechanism;
- c. Total number and percentage of tubes plugged to date;
- d. The results of condition monitoring, including the results of tube pulls and in-situ testing;
- e. The primary to secondary leakage rate observed in each SG;
- f.
The calculated accident leakage rate from the portion of the tube below 15.2 inches from the top of the tubesheet for the most limiting accident in the most limiting SG; and
- g. The results of monitoring for the tube axial displacement (slippage).
Attachment to ET 11-0008 Page 3 of 8 STEAM GENERATOR TUBE INSPECTION REPORT Section 1: Scope and Examination Techniques of Inspections Performed The actual inspections performed during Refueling Outage 18 meet or exceed both the Technical Specification minimum requirements and the requirements of the Electric Power Research Institute (EPRI) Pressurized Water Reactor (PWR) Steam Generator Examination Guidelines. The following primary side inspections were performed in all four SGs:
25% Bobbin examination of tubes, full length except for Rows 1 and 2, which are inspected with the bobbin from tube end to tube support plate (TSP) #7 on both the hot leg (HL) and cold leg (CL).
25% HL +Point rotating pancake coil (RPC) examination, tube sheet (TS) +3"/-15.2".
0 HL RPC TS +3"/-1 5.2" of the peripheral tubes, 2 pitches into the bundle.
CL Peripheral Tubes, CL tube sheet (TSC) +/- 3" 100% of peripheral tubes; 2 pitches into the bundle.
+Point examination of all "I-code" indications that are not resolved after history review.
0
+Point inspection of new flow distribution baffle (FDB) wear indications and prior FDB wear indications that have changed by 10% TWD or greater by bobbin.
Visual inspection of mechanical and weld plugs.
+Point inspection to bound (all surrounding tubes, at least 1 pitch removed) the tubes exhibiting possible loose parts (PLP) signals during the inspection.
+Point inspection of PLP signals from the previous inspection.
25% Row 1 and Row 2 U-bends, mid-range +Point examination.
Dents (structures) -Ž2 volts: Inspect 25% in SG A/D and 50% in SG B/C of all previously identified and 100% of new dents a-2 volts in the HL (including the U-bends) with the mid-range +Point probe in all four SG's.
0 Dings (freespan) >5 volts: Inspect 25% of all previously identified and 100% of new dents >5 volts in the HL (including the U-bends) with the mid-range +Point probe in all four SG's.
100% Bobbin inspection of all prior indications except dents and dings.
+Point examination of a 5% sample of bobbin indications that have not changed since the prior inspection ("H" and "S" codes).
0
+Point inspection of the sample of tubes to support the scale profiling effort.
100% Bobbin inspection of tubes surrounding previously plugged tubes being monitored for potential long term damage propagation and tubes with potentially elevated residual stress.
Attachment to ET 11-0008 Page 4 of 8 STEAM GENERATOR TUBE INSPECTION REPORT In order to increase the probability of detecting foreign object wear, the base bobbin scope and TTS RPC was performed on different tubes. Auto Analysis (ADS) was performed as a tertiary review to the normal analysis process, utilizing sorts established to increase the confidence that top of tubesheet defects (DTI), PLP, indications of tube sever within the tubesheet (TSI),
support defects (DSI) and other significant flaws (>30% TWD) were detected. The sorts used were qualified against a data set made up of previous plant indications and indications that were "injected" into WCGS data by Data Union software. The tertiary review did not identify any indications that were not already called by primary and/or secondary analysis.
During the inspection, a C-2 finding for AVB wear in SG B led to a scope expansion. This was due to a single defective tube (45%) that had a growth rate of 25% over two cycles.
An additional 20% of the unscheduled tubes in rows >15 were inspected.
No further scope expansion was required.
In addition, the following secondary side maintenance and inspections were performed:
Sludge Lancing of all four SGs Foreign Object Search and Retrieval (FOSAR) to locate, identify, and retrieve foreign objects that were present on the steam generator TS in all four SGs. FOSAR was also performed to inspect for any PLP identified during the Eddy Current Program.
TTS In-Bundle Inspection (IBI) of SGs B and C to inspect the condition of the top of the TS and to augment the FOSAR effort.
Upper Steam Drum Inspection in SGs B and C to evaluate the condition of the upper steam drum components with regard to damage of any kind.
o 100% visual inspection of J-nozzles o
Ultrasonic sample of feedring locations and J-nozzles Section 2: Indication Listing The following Enclosures contain all service-induced indications for all four SGs.
This encompasses the location, orientation (if linear), and measured sizes (if available) of service induced indications : Steam Generator A Service-Induced Indications : Steam Generator B Service-Induced Indications : Steam Generator C Service-Induced Indications : Steam Generator D Service-Induced Indications The key below provides a description of the abbreviations used in the tables.
Attachment to ET 11-0008 Page 5 of 8 STEAM GENERATOR TUBE INSPECTION REPORT COL Column PER Percent LOCN Location INCH1 Distance from location
- H, #C
(# = Support Plate Number) Hot Leg or Cold Leg Side AV#
Anti-Vibration Bar (# = number)
TSH Tube Sheet Hot Leg TSC Tube Sheet Cold Leg FBC Flow Baffle Cold Leg FBH Flow Baffle Hot Leg
Attachment to ET 11-0008 Page 6 of 8 STEAM GENERATOR TUBE INSPECTION REPORT Section 3: Inspection Results Active Degradation Mechanisms Found Note: "Active" degradation mechanism is a historical term (prior to the current Revision 7 of the EPRI PWR Steam Generator Examination Guidelines).
This term has been replaced with "Existing" degradation mechanism.
Existing Degradation is defined as indications of degradation previously and/or currently observed in a Steam Generator.
The inspection results indicate that wear at AVB locations, wear at the flow distribution baffle, and wear due to foreign objects are existing degradation mechanisms.
Stress Corrosion Cracking at the tube ends is also considered an existing degradation mechanism.
However, an alternate repair criterion, H*, was approved for RF18.
This eliminated the need to inspect the tubes below 15.2 inches from the top of the tubesheet.
Identification of Tubes Pluaaed No tubes in SG A required plugging during Refuel 18.
Row 40 44 45 45 46 50 50 51 53 Row 40 45 49 Column 81 100 53 74 61 37 47 64 50 Column 101 69 75 Column 34 104 35 Attribution AVBWear AVBWear AVBWear AVBWear AVBWear AVBWear AVBWear AVBWear AVBWear Attribution AVBWear AVBWear AVBWear Attribution AVBWear AVBWear AVBWear Steam Generator C:
Row 48 40 53
Attachment to ET 11-0008 Page 7 of 8 STEAM GENERATOR TUBE INSPECTION REPORT Total Number of Tubes Plugqqed in Each Steam Generator Steam Generator Total Number of Total Percentage Tubes Plugged Plugged A
- 42 0.75%
B 62 1.10%
C 31 0.55%
D 131 2.33%
- An additional 3 plugs are installed in SG A cold leg only, due to tubesheet drilling errors during manufacturing. No tubes are installed in those locations.
Results of Condition Monitorinq The examination results confirm that the WCGS SGs currently meet all industry and regulatory structural and leakage integrity guidance. No indications were found to exceed structural limits.
No tube pulls or in-situ testing were required.
" AVB wear remains an existing degradation mechanism.
The maximum observed indication (45% TWD at an AVB location) meets the structural and leakage requirements.
" Tube wear at the FDB is an existing degradation mechanism that is not progressing.
Wear at the FDB is attributed to a prior application of pressure pulse cleaning of the SGs.
No new indications were reported as expected; all indications were previously reported at Refuel 16 and Refuel 17. The magnitude of the wear does not challenge the performance requirements for condition monitoring.
Tube wear detected at three TSP intersections in SG D is an existing degradation mechanism that is not progressing. This degradation mechanism is not an operational degradation mechanism but is the result of transient foreign objects interacting with the tubes. The current indications of wear at the tube support plates meet the performance criteria for condition monitoring.
Volumetric indications detected at the TTS have not changed since the prior inspections at Refuel 16 and Refuel 17. The reported changes in depth are small and within the normal variability of the sizing technique. The likely source of these indications is wear due a transient foreign object at a prior time. No new wear indications from foreign objects were detected. No foreign objects were found among the tubes with volumetric indications and their neighboring tubes. The largest indication is 26% TWD, which poses no challenge to the condition monitoring performance criteria.
No corrosion related degradation mechanisms were observed.
No degradation indications were observed related to potential precursor signals such as dents and dings, or to interferences such as permeability variations, etc.
" Leakage is not an issue for any indication reported. There is currently no leakage in the SGs.
All plugs were found to be in acceptable condition based on visual inspection.
No wear was found on any tube adjacent to a tube that had previously been identified as potentially requiring stabilization due to continuing wear after plugging for AVB wear.
The absence of wear on adjacent tubes indicates that continuing wear of the plugged
Attachment to ET 11-0008 Page 8 of 8 STEAM GENERATOR TUBE INSPECTION REPORT tubes is progressing at a slower rate than predicted, confirming the analysis that significant margin in time exists before potential stabilization would be required.
" The accident induced leakage requirements for H* were met without the need for a change in the administrative leakage limit.
No evidence of tube slippage was found.
Sludge lancing activities removed 26 pounds from SG A, 34 pounds from SG B, 30 pounds from SG C, and 27.5 pounds from SG D.
FOSAR activities in SGs A, B, C, and D identified and removed some minor foreign objects. All foreign objects were bound using the Plus Point probe. In addition, PLP indications reported by eddy current testing were further evaluated by visual inspection and bounded using the Plus Point probe.
No degradation was associated with any foreign object or PLP indication.
Minor foreign objects remaining in the SGs were evaluated by analysis and are acceptable for continued operation.
Secondary side visual inspection activities performed at the top of the tubesheet in SGs B and C were successful in gathering additional information which is used to determine future maintenance and cleaning strategies. No degradation was identified during this inspection.
Upper steam drum visual and ultrasonic inspections in SG B and C collected additional data used for monitoring and trending of upper steam drum components.
Minor degradation is being monitored at a few J-Nozzle to Feedring interface locations. All results were within acceptance criteria.
No other degradation was observed during these inspections.
Analysis of the data collected for scale profiling is on-going and is expected in January of 2012.
No immediate concerns are expected from this analysis. Previous analysis shows that the majority of scale deposits are located in the U-bend regions and upper tube support plate bundle on the hot leg side. At tube support plate quatrefoil locations, the majority of the locations examined have been clean. This information is used in conjunction with visual data to continue trending the condition of the secondary side of the steam generators in order to plan future maintenance and cleaning strategies.
to ET 11-0008 Steam Generator A Service-Induced Indications (21 pages)
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCHI1
+
1 25 8
11 AVI
.001 28 9
14 AV2
.001 28 9
14 AV5
.001 27 10 10 AV5
.00I 30 10 12 AV2
.001 30 10 15 AV5
.001 30 10 16 AV6
.001 35 14 11 AVi
.001 38 19 17 AV4
.001 40 19 14 AV2
.001 40 19 19 AV5
.001 35 20 16 AV3
.001 40 20 11 AV5
.001 42 22 11 AV4
.001 42 22 21 AV5
.001 38 25 17 AV2
.00I 38
- 25.
16 AV6
.001 39 25 20 AV2
.001 45 25 31 AV2
.001 45 25 26 AV3
.001 45 25 24 AV4
.001 45 25 33 AV5
.001 45 25 17 AV6
.001 27 26 21 AV5
.001 45 26 26 AV3
.001 45 26 30 AV4
.001 45 26 20 AV5
.001 I ROW COL PER LOCN INCH11
+-- -. -
+-
1 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCHI1
+
1 39 27 17 AV3
.001 40 27 17 AV2
.001 48 27 17 AV4
.001 48 27 18 AV5
.001 44 28 13 AV3
.001 44 28 20 AV5
.001 I 37 29 20 AV6
.001 38 29 17 AV2
.001 38 29 17 AV3
.001 40 29 16 AV2
.001 41 29 19 AV4
.001 41 30 16 AV4
.001 41 30 15 AV5
.001 45 30 22 AV2
.001 45 30 30 AV3
.001 45 30 16 AV4
.001-45 30 19 AV5
.001 50 30 15 AV5
.001 23 31 14 AVi
.001 41 31 21 AV2
.001 41 31 24 AV4
.001 44 31 20 AV4
.001 37 32 13 AV4
.001 41 32 16 AV2
.001 41 32 27 AV3
.001 41 32 17 AV4
.001
+.
+
I ROW COL PER LOCN INCH11
+.
+
2 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCH11
-+--
-+-- - -+--
-+-----+
1 45 32 20 AV2
.001 1 45 32 23 AV3
.001 1 45 32 36 AV4
.001 1 45 32 30 AV5
.001 1 45 32 20 AV6
.001 47 32 18 AV2
.001 47 32 35 AV3
.001 47 32 28 AV4
.001 47 32 18 AV5
.001 47 32 15 AV6
.001 34 33 17 AV4
.001 38 33 14 AV3
.001 45 33 32 AV4
.001 45 34 19 AV2
.001 45 34 28 AV4
.001 47 34 20 AV3
.001 47 34 18 AV4
.001 50 34 17 AV1
.001 50 34 21 AV2
.001 50 34 16 AV3
.001 48 35 19 AV2
.001 48 35 23 AV3
.001 48 35 21 AV4
.001 48 35 23 AV5
.001 33 36 20 AV2
.001 33 36 16 AV3
.001 33 36 14 AV5
.001 35 36 18 AV5
.001 43 36 18 AV3
.001 43 36 19 AV4
.001
- -+-
- - -+---
-+-----+
I ROW COL PER LOCN INCH11
-+---
-+--
- -+---
+------+
3 ST Max
SG -
A Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+.
+.
+
I ROW COL PER LOCN INCH11
-+--
-+-- - -+--
-+-------
1 45 36 22 AV2
.001 47 36 15 AV2
.001 36 37 18 AV3
.001 36 37 18 AV4
.001 37 37 19 AV5
.001 38 37 20 AV5
.001 45 37 21 AV2
.001 45 37 30 AV3
.001 45 37 16 AV4
.001 45 37 16 AV6
.001 48 37 25 AV3
.001 30 38 15 AV5
.001 40 38 21 AV4
.001 41 38 18 AV4
.001 43 38 18 AV2
.001 43 38 38 AV3
.001 43 38 23 AV4
.001 43 38 23 AV5
.001 45 38 16 AV1
.001 45 38 28 AV3
.001 45 38 25 AV4
.001 48 38 16 TSH
.001 39 39 24 AV3
.001 39 39 24 AV4
.001 39 39 21 AV5
.001 39 39 26 AV6
.001 44 39 26 AV2
.001 44 39 22 AV3
.001
+
I ROW COL PER LOCN INCH11
+
4 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCH11
++
1 44 39 36 AV4
.001 1 44 39 28 AV5
.001 44 39 20 AV6
.001 I38 40 19 AV2
.00 1 38 40 21 AV3
.001 38 40 18 AV5
.001 38 40 17 AV6
.001 41 40 18 AV2
.001 41 40 17 AV5
.001 41 40 22 AV6
.001 43 40 18 AV5
.00I 44 40 14 AV1
.001 44 40 18 AV2
.001 44 40 15 AV3
.001 45 40 19 AV3
.001 45 40 33 AV4
.001 45 40 22 AV5
.001 46 40 20 AVI
.001 46 40 32 AV2
.00!
46 40 38 AV4
.001 46 40 34 AV5
.001 27 41 17 AV2
.001 27 41 21 AV5
.001 28 41 16 AV2
.001 28 41 18 AV5
.001 38 41 15 AV2
.001 38 41 29 AV3
.001 38 41 24 AV4
.001 38 41 16 AV6
.001 40 41 20 AV3
.001 40 41 20 AV4
.001
+
I ROW COL PER LOCN INCHI1
+
5 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCH11
+
41 41 15 AV3
.001 44 41 17 AV3
.001 44 41 23 AV4
.001 44 41 33 AV5
.001 44 41 21 AV6
.001 45 41 19 AV2
.001 45 41 36 AV3
.001 45 41 30 AV4
.001 45 41 30 AV5
.001 45 41 22 AV6
.001 26 42 16 AV2
.001 26 42 17 AV5
.001 I
27 42 20 AV5
.001 30 42 19 AV2
.001 36 42 15 AVi
.001 36 42 22 AV2
.001 36 42 21 AV3
.001 36 42 22 AV4
.001 36 42 30 AV5
.001 36 42 14 AV6
.001 40 42 17 AV2
.001 40 42 20 AV3
.001 40 42 25 AV4
.001 40 42 20 AV5
.001 40 42 19 AV6
.001 48 42 17 AV4
.001 56 42 15 AV6
.001 28 43 16 AV2
.001 36 43 22 AV2
.001 36 43 19 AV5
.001
+
I ROW COL PER LOCN INCH11
-+--
-+--
-+-----+
6 ST Max
SG -
A Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+.
+
I ROW COL PER LOCN INCH11
+.
+
1 41 43 16 AV2
.001 41 43 24 AV3
.001 41 43 14 AV4
.001 41 43 33 AV5
.001 41 43 13 AV6
.001 30 44 22 AV5
.001 35 44 15 AV5
.001 38 44 18 AV5
.001 41 44 22 AV2
.001 41 44 26 AV3
.001 41 44 22 AV4
.001 41 44 19 AV5
.001 41 44 19 AV6
.001 43 44 20 AV3
.001 43 44 18 AV5
.001 28 45 22 AV5
.001 28 45 15 AV6
.001 35 45 16 AV1
.001 35 45 22 AV2
.001 36 45 14 AVi
.001 36 45 22 AV2
.001 36 45 19 AV3
.001 36 45 26 AV4
.001 36 45 27 AV5
.001 36 45 22 AV6
.001 37 45 16 AV6
.001 38 45 16 AV3
.001 38 45 15 AV4
.001 38 45 18 AV5
.001 38 45 17 AV6
.001 39 45 36 AV4
.001
-+
+-
-+----------+
I ROW COL PER LOCN INCH11
+
7 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCH11
+
1 39 45 27 AV5
.001 40 45 16 AV2
.001 40 45 13 AV3
.001 40 45 16 AV4
.001 40 45 13 AV5
.001 41 45 16 AV5
.001 41 45 14 AV6
.001 43 45 12 AVi
.001 43 45 13 AV3
.001 44 45 22 AV3
.001 44 45 24 AV4
.001 44 45 17 AV5
.001 44 45 15 AV6
.001 26 46 16 AV2
.001 26 46 17 AV5
.001 28 46 18 AVI
.001 28 46 21 AV2
.001 28 46 34 AV5
.001 28 46 15 AV6
.001 30 46 23 AV2
.001 33 46 19 AV3
.001 34 46 15 AV3
.001 35 46 16 AV2
.001 35 46 17 AV3
.001 35 46 20 AV4
.001 39 46 34 AV2
.001 39 46 29 AV3
.001 39 46 33 AV4
.001 43 46 16 AV2
.001 43 46 18 AV3
.001
-+--
-+-
-- +-----+
I ROW COL PER LOCN INCH11
+
8 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+.
+
I ROW COL PER LOCN INCHlI
+.. 3. 46 35..+
A... 4-
-+-
1 43 46 35 AV4
.001 1 43 46 17 AV5
.001 43 46 17 AV6
.001 44 46 26 AV2
.001 44 46 30 AV3
.001 44 46 24 AV4
.001 44 46 18 AV5
.001 49 46 29 AV3
.001 49 46 25 AV4
.001 50 46 16 AV2
.001 50 46 31 AV3
.001 50 46 26 AV4
.001 32 47 17 AV5
.001 34 47 21 AV2
.001 34 47 17 AV3
.001 34 47 24 AV5
.001 36 47 12 AV3
.001 36 47 15 AV5
.001 37 47 22 AV3
.001 37 47 32 AV4
.001 37 47 22 AV5
.001 39 47 14 AV2
.001 39 47 16 AV4
.001 39 47 18 AV5
.001 42 47 16 AV5
.001 42 47 15 AV6
.001 44 47 18 AV2
.001 26 48 18 AV5
.001 36 48 22 AV5
.001
+
I ROW COL PER LOCN INCH11
+
9 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24 I ROW COL PER LOCN INCH11
+
1 37 48 19 AV2
.001 37 48 18 AV3
.001 37 48 14 AV5
.001 38 48 29 AV2
.001 38 48 28 AV3
.001 38 48 18 AV4
.001 38 48 17 AV5
.001 40 48 15 AV4
.001 40 48 20 AV5
.001 40 48 16 AV6
.001 44 48 18 AV2
.001 22 49 16 AV2
.001 22 49 13 AV6
.001 24 49 14 AV2
.001 36 49 18 AV2
.00I 36 49 15 AV3
.001 36 49 19 AV4
.001 40 49 19 AV2
.001 40 49 24 AV3
.001 40 49 19 AV4
.001 40 49 13 AV5
.001 36 50 17 AV2
.001 36 50 22 AV3
.001 36 50 22 AV4
.001 36 50 17 AV5
.00I 36 50 12 AV6
.001 38 50 18 AV4
.001 39 50 19 AV4
.001 27 51 17 AV5
.001 36 52 13 AV2
.001
+
I ROW COL PER LOCN INCH11
..-.--------------------------+
10 ST Max
SG -
A Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCH11
+
1 38 52 24 AV3
.001 1 38 52 21 AV4
.001 38 52 15 AV5
.001 40 52 23 AV2
.001 40 52 19 AV3
.001 40 52 31 AV4
.001 40 52 30 AV5
.001 40 52 23 AV6
.001 43 52 21 AV2
.001 33 53 20 AV2
.001 33 53 16 AV3
.001 33 53 18 AV4
.001 33 53 13 AV5
.001 34 53 18 AV2
.001 36 53 15 AV6
.001 38 53 13 AV3
.001 40 53 17 AV3
.001 41 53 14 AV3
.001 42 53 20 AV2
.001 42 53 17 AV3
.001 42 53 16 AV4
.001 42 53 29 AV5
.001 49 53 17 AV5
.001 49 53 15 AV6
.001 35 54 21 AV2
.001 35 54 19 AV3
.001 36 54 24 AV3
.001 36 54 20 AV5
.001
+
I ROW COL PER LOCN INCH11 11 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCHI1 1 37 54 17 AV2
.001 40 54 14 AV2
.001 41 54 14 AV4
.001 41 54 36 AV5
.001 41 54 18 AV6
.00!
42 54 13 AV4
.001 42 54 25 AV5
.001 18 55 21 AV1
.001 36 55 20 AV5
.001 38 55 16 AVi
.001 38 55 19 AV2
.001 38 55 28 AV3
.001 38 55 30 AV4
.001 42 55 16 AV4
.001 50 55 22 AV2
.00!
35 56 20 AV2
.00!
44 56 23 AV2
.001 44 56 30 AV3
.001 44 56 26 AV4
.001 44 56 25 AV5
.001 23 57 17 AVI
.001.
23 57 16 AV2
.00!
23 57 21 AV5
.00!
42 57 18 AV3
.00!
19 58 20 AVi
.001 19 58 18 AV6
.001 29 58 16 AV5
.001 I ROW COL PER LOCN INCH11
-+-
-+-
12 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24 I ROW COL PER LOCN INCH11
+
1 31 58 18 AV1
.00!
31 58 23 AV2
.001 31 58 20 AV5
.001 41 58 25 AV2
.001 41 58 20 AV3
.001 43 58 31 AV2
.001 43 58 25 AV3
.001 43 58 28 AV4
.001 43 58 28 AV5
.001 34 59 14 AV4
.001 39 59 14 AV3
.001 39 59 15 AV5
.001 41 59 18 AV2
.001 41 59 23 AV3
.001 41 59 17 AV4
.001 44 59 28 AV2
.001 44 59 33 AV3
.001 44 59 18 AV4
.001 44 59 14 AV6
.001 44 60 24 AV3
.001 44 60 20 AV4
.001 44 60 18 AV5
.001 44 60 14 AV6
.001 34 61 22 AV4
.001 34 61 14 AV5
.001 38 61 15 AV3
.001 42 61 20 AV2
.001 50 61 15 AV4
.001 50 61 16 AV5
.001 36 62 16 AV2
.001
+
I ROW COL PER LOCN INCH11 13 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24 I ROW COL PER LOCN INCH11
+
36 63 15 AV2
.001 36 63 12 AV3
.001 37 64 17 AV2
.001 37 64 19 AV3
.001 37 64 16 AV4
.001 37 64 13 AV5
.001 37 64 16 AV6
.001 57 64 20 AV1
.001 57 64 16 AV2
.001 40 65 15 AV2
.001 44 66 14 AV3
.001 51 66 23 AV2
.001 51 66 15 AV3
.001 38 67 18 AV5
.001 42 68 21 AV3
.001 49 68 21 AV2
.001 49 68 19 AV3
.001 49 68 19 AV5
.001 40 69 15 AV3
.001 40 70 16 AV1
.001 40 70 31 AV3
.001 40 70 27 AV4
.001 40 70 17 AV5
.001 40 70 16 AV6
.001 50 70 31 AV2
.001 27 71 15 AV2
.001 37 74 15 AV1
.001 37 74 33 AV3
.001
.- -+--
-. -+-
I ROW COL PER LOCN INCH11 14 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24 I ROW COL PER LOCN INCH11
+
1 37 74 33 AV4
.001 1 37 74 32 AV5
.001 1 37 74 14 AV6
.001 39 75 16 AV3
.001 41 75 17 AV2
.001 41 75 23 AV3
.001 41 75 23 AV4
.001 41 75 30 AV5
.001 41 75 15 AV6
.001 42 75 18 AVI
.001 44 75 22 AV3
.001 44 75 23 AV4
.001 44 75 24 AV5
.001 44 75 14 AV6
.001 39 76 26 AV2
.001 39 77 17 AV3
.001 44 77 24 AV4
.001 44 77 16 AV5
.001 58 77 13 AV6
.001 34 78 20 AV2
.001 34 78 16 AV3
.001 34 78 24 AV5
.001 39 78 17 AV3
.001 39 78 17 AV5
.001 39 78 19 AV6
.001 36 79 15 AV4
.001 39 79 17 AV2
.001 39 79 19 AV3
.001 39 79 24 AV4
.001 39 79 17 AV5
.001
+
I ROW COL PER LOCN INCH11
+
15 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCHI1
-+-
+
1 27 80 19 AV5
.001 34 80 17 AV1
.001 34 80 23 AV2
.001 40 80 19 AV2
.001 28 81 12 AV2
.001 28 81 12 AV5
.001 39 81 15 AV2
.001 39 81 17 AV4
.001 39 81 20 AV5
.001 44 81 16 AV2
.001 46 81 15 AV2
.001 46 81 16 AV3
.001 46 81 14 AV5
.001 56 81 15 AV5
.001 27 82 12 AV2
.001 27 82 20 AV5
.001 36 82 12 AV2
.001 39 82 16 AV2
.001 39 82 19 AV4
.001 40 82 20 AV2
.001 40 82 17 AV3
.001 40 82 15 AV4
.001 40 82 19 AV5
.001 36 83 22 AV1
.001 46 83 18 AVi
.001 46 83 22 AV2
.001 25 84 12 AV2
.001 I ROW COL PER LOCN INCH11
- -- -+
-+
16 ST Max
SG -
A Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
- -- -+
+.-
+
I ROW COL PER LOCN INCHI1
- -+-----
+
34 84 17 AV2
.001 34 84 20 AV3
.001 34 84 14 AV4
.001 34 84 16 AV5
.001 36 84 14 AV5
.001 39 84 13 AVi
.001 39 84 33 AV2
.001 39 84 34 AV3
.001 39 84 21 AV4
.001 39 84 24 AV5
.001 39 84 21 AV6
.001 44 84 15 AV3
.001 44 84 15 AV4
.001 44 84 14 AV5
.001 45 84 16 AV4
.001 53 84 14 AV5
.001 55 84 26 AV5
.001 33 85 11 AV3
.001 33 85 14 AV4
.001 39 85 20 AV2
.001 39 85 37 AV3
.001 39 85 38 AV4
.001 39 85 27 AV5
.001 39 85 21 AV6
.001 54 85 17 AV5
.001 25 86 14 AV5
.001 30 86 16 AV5
.001 31 86 27 AV5
.001
-+--
- -+-
- -+-----
I ROW COL PER LOCN INCH11 17 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24 I ROW COL PER LOCN INCH11
+.
+
1 36 86 16 AV2
.001 46 86 13 AV1
.001 46 86 19 AV2
.001 46 86 26 AV3
.001 46 86 15 AV4
.001 26 87 16 AV5
.001 30 87 21 AV5
.001 30 87 17 AV6
.001 39 87 17 AV1
.001 39 87 14 AV2
.001 39 87 18 AV3
.001 39 87 37 AV4
.001 39 87 17 AV5
.001 39 87 14 AV6
.001 44 87 19 AV2
.001 44 87 20 AV3
.001 50 87 18 AVI
.001 50 87 18 AV2
.001 50 87 19 AV3
.001 50 87 22 AV4
.001 50 87 25 AV5
.001 20 88 18 AV6
.001 30 88 17 AV2
.001 30 88 17 AV5
.001 38 89 25 AV5
.001 39 89 18 AV4
.001 44 89 21 AV2
.001 44 89 22 AV3
.001 44 89 34 AV4
.001 44 89 20 AV5
.001 44 89 22 AV6
.001
+ ----. ----..
- +
I ROW COL PER LOCN INCH11
-+--
-+-
+
18 ST Max
SG -
A Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24 S-----
+
I ROW COL PER LOCN INCH11 30 90 13 AV5
.001 40 90 15 AV6
.001 50 90 13 AV4
.001 50 90 30 AV5
.001 35 91 20 AV1
.001 35 91 28 AV4
.001 36 91 26 AV2
.001 36 91 29 AV4
.001 36 91 15 AV5
.001 36 91 25 AV6
.001 41 91 21 AV6
.001 26 92 18 AV5
.001 35 92 17 AV3
.001 35 92 12 AV4
.001 35 92 13 AV5
.001 35 92 12 AV6
.001 36 92 12 AV2
.001 36 92 17 AV5
.001 38 92 19 AV5
.001 38 92 17 AV6
.001 44 92 19 AV3
.001 44 92 28 AV4
.001 44 92 15 AV5
.001 38 93 23 AV5
.001 39 93 15 AV2
.001 39 93 31 AV3
.001 39 93 18 AV4
.001 39 93 20 AV5
.001 I ROW COL PER LOCN INCH11
+
19 ST Max
SG A
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24 I ROW COL PER LOCN INCH11
-+
39 94 15 AV3
.001 39 94 15 AV5
.001 20 95 15 AV6
.001 38 95 18 AV4
.001 38 95 22 AV5
.001 39 95 16 AV2
.001 39 95 20 AV3
.001 39 95 23 AV4
.001 39 95 15 AV5
.001 39 96 19 AV3
.001 39 96 20 AV4
.001 27 97 11 AVI
.001 27 97 20 AV2
.001 35 97 21 AV4
.001 37 97 18 AV2
.001 37 97 19 AV3
.001 37 97 16 AV4
.001 37 97 22 AV5
.001 38 97 15 AV3
.001 37 98 12 AV2
.001 37 98 17 AV3
.00I 38 98 19 AV3
.001 38 98 22 AV4
.001 39 98 15 AV3
.001 35 99 20 AV5
.00I 38 99 17 AV2
.001 38 99 15 AV3
.001 38 99 27 AV4
.001 I ROW COL PER LOCN INCH1I 20 ST Max
SG - A Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:53:24
+
I ROW COL PER LOCN INCHI1
-+--
- -+--
- -+---
+
1 37 100 13 AV3
.001 1 37 100 15 AV4
.001 39 101 17 AV3
.001 39 101 21 AV4
.001 39 101 18 AV5
.001 39 102 15 AV4
.001 40 102 21 AV3
.001 40 102 17 AV4
.001 40 102 18 AV5
.001 40 103 18 AV3
.001 40 103 18 AV4
.001 40 103 18 AV6
.001 43 103 14 AV3
.001 37 104 16 TSH 4.431 138 106 15 AV4
.00 38 106 13 AV5
.001 26 109 20 AV2
.001 27 109 18 AV2
.001 36 109 14 AV4
.001 36 110 16 AV2
.001 36 110 15 AV3
.001 36 110 29 AV4
.001 36 110 37 AV5
.001 36 110 19 AV6
.001 I ROW COL PER LOCN INCH11
+
Tubes: 275 Records: 601 21 ST Max to ET 11-0008 Steam Generator B Service-Induced Indications (34 pages)
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
+
17 5
25 2C
-. 421 26 7
16 AV2
.001 26 7
12 AV5
.001 27 8
28 AV2
.001 27 8
16 AV5
.001 27 9
19 AVi
.001 27 9
18 AV5
.001 28 9
16 AV5
.001 29 9
21 AV2
.001 29 9
20 AV5
.001 30 9
38 AV2
.001 30 9
23 AV5
.001 27 10 14 AV2
.001 27 10 10 AV5
.001 30 10 15 AV2
.001 30 10 25 AV5
.001 32 12 12 AV2
.001 32 12 19 AV4
.001 32 12 23 AV5
.001 33 12 17 AV2
.001 33 12 24 AV5
.001 33 12 17 AV6
.001 32 14 13 AV5
.001 34 16 17 AV5
.001 45 22 29 AV5
.001 45 22 34 AV6
.001 42 23 14 AVI
.001 1 42 23 14 AV2
.001
-+---
-+--
-+-
-+-----+
I ROW COL PER LOCN INCH11
+
1 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCHI1
- - -+-
+
1 42 23 20 AV3
.001 1 42 23 20 AV4
.001 1 42 23 12 AV6
.001 S44 23 13 AV3
.001 44 23 15 AV4
.001 30 24 25 TSH
.271 45 24 14 AV2
.001 45 24 12 TSC
.321 46 24 18 AV5
.001 46 24 10 AV6
.001 47 24 18 AV5
.001 47 24 17 AV6
.001 46 25 16 AV2
.001 46 25 27 AV3
.001 46 25 35 AV4
.001 46 25 34 AV5
.001 46 25 22 AV6
.001 47 25 14 AV6
.001 48 25 19 AV5
.001 48 25 18 AV6
.001 49 27 18 AV6
.001 49 28 19 AV4
.001 49 28 32 AV5
.001 49 28 21 AV6
.001 49 29 19 AV3
.001 49 29 18 AV5
.001 44 30 14 AV4
.001 44 30 12 AV5
.001 30 31 16 AV2
.001
-+--
-+-- - -+--
-+-----+
I ROW COL PER LOCN INCH11
+
2 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11 43 31 14 AV5
.001 49 31 13 AV2
.001 49 31 29 AV5
.001 49 31 14 AV6
.001 1
32 18 FBC
-. 351 1
32 18 FBC
.351 22 32 30 FBH 1.631 48 32 16 AV5
.001 48 32 14 AV6
.00I 1
33 14 FBC
-. 241 1
33 15 FBC
.271 28 33 14 AV5
.001 28 33 15 AV6
.001 45 33 21 AV3
.001 49 33 17 AV2
.001 49 33 25 AV3
.001 49 33 21 AV4
.001 49 33 39 AV5
.001 49 33 18 AV6
.001 51 33 15 AV5
.001 51 33 16 AV6
.001 44 34 18 AV2
.001 44 34 21 AV3
.001 44 34 21 AV4
.001 44 34 18 AV5
.001 49 34 10 AV2
.001 49 34 14 AV3
.001 49 34 14 AV4
.001 36 35 21 AV2
.001
+
I ROW COL PER LOCN INCH11
+
3 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+---------------------------
I ROW COL PER LOCN INCH11
+
1 36 35 16 AV3
.001 1 36 35 22 AV4
.001 53 35 10 AV2
.001 53 35 29 AV4
.001 53 35 35 AV5
.001 53 35 19 AV6
.001 19 36 20 1H 18.971 36 36 16 AV3
.001-42 36 24 AV2
.001 42 36 13 AV3
.001 42 36 17 AV4
.001 49 36 16 AV2
.001 49 36 24 AV3
.001 49 36 36 AV4
.001 49 36 26 AV5
.001 49 36 14 AV6
.001 25 37 18 AV5
.001 36 37 18 AV3
.001 36 37 22 AV4
.001 36 37 17 AV5
.001 49 37 16 AV2
.001 49 37 19 AV3
.001 49 37 21 AV4
.001 49 37 25 AV5
.001 49 37 16 AV6
.001 50 37 19 AV3
.001 50 37 41 AV4
.001 50 37 35 AV5
.001 54 37 16 AV3
.001 54 37 18 AV5
.001 36 38 13 AV2
.001 I ROW COL PER LOCN INCH11 4
ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+.
+
I ROW COL PER LOCN INCH11
+
42 38 15 AV5
.001 42 38 12 AV6
.001 45 38 18 AV4
.001 47 38 27 AV3
.001 50 38 27 AV3
.001 50 38 37 AV4
.001 50 38 25 AV5
.00I 39 39 15 AVi
.001 39 39 14 AV2
.001 41 39 12 AV2
.001 42 39 14 AV2
.001 42 39 19 AV3
.001 42 39 19 AV4
.001 42 39 18 AV6
.001 45 39 12 AVI
.001 45 39 18 AV2
.001 I 45 39 13 AV3
.001 55 39 16 AV2
.001 36 40 15 AVi
.001 41 40 14 AV4
.001 41 40 13 AV6
.001 42 40 17 AV2
.001 42 40 21 AV3
.001 42 40 14 AV6
.001 45 40 15 AV2
.001 47 40 13 AV2
.001 54 40 11 AV2
.001
+
I ROW COL PER LOCN INCH11
-- -+--
- -+--
- -+---
+------+
5 ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11 1 55 40 16 AV4
.001 39 41 17 AV4
.001 41 41 16 AV3
.001 42 41 13 AV3
.001 42 41 15 AV4
.001 42 41 27 AV5
.001 42 41 12 AV6
.001 46 41 20 AV2
.001 48 41 21 AV3
.001 38 42 15 AV3
.001 39 42 23 AV4
.001 39 42 13 AV6
.001 41 42 12 AV3
.001 41 42 25 AV4
.001 41 42 17 AV5
.001 44 42 10 AV3
.001 44 42 13 AV4
.001 47 42 19 AV2
.001 48 42 15 AV4
.001 37 43 17 AVi
.001 37 43 21 AV2
.001 37 43 22 AV3
.001 43 43 14 AVi
.001 43 43 18 AV3
.001 44 43 14 AV2
.001 44 43 22 AV3
.001 44 43 21 AV4
.001
- -. -+-
I ROW COL PER LOCN INCH11 6
ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
+
1 44 43 15 AV5
.001 46 43 20 AV6
.001 47 43 17 AV1
.001 47 43 12 AV2
.001 47 43 21 AV3
.001 52 43 16 AV1
.001 56 43 15 AV4
.001 56 43 31 AV5
.001 44 44 15 AV3
.001 44 44 14 AV4
.001 44 45 14 AV3
.001 44 45 24 AV4
.001 44 45 19 AV5
.001 47 45 19 AVi
.001 47 45 17 AV2
.001 47 45 14 AV3
.001 47 45 17 AV4
.001 48 45 39 AV4
.001 48 45 26 AV5
.001 48 45 23 AV6
.001 52 45 10 AVi
.001 52 45 15 AV2
.001 52 45 23 AV3
.001 52 45 22 AV4
.001 52 45 20 AV5
.001 34 46 20 AV4
.001 44 46 21 AV1
.001 44 46 37 AV2
.001 44 46 31 AV3
.001 44 46 27 AV4
.001 44 46 29 AV5
.001
+ ----.-
+
I ROW COL PER LOCN INCH11
+
7 ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+.
+
I ROW COL PER LOCN INCH11
+.
+
45 46 14 AV2
.001 45 46 15 AV3
.001 47 46 20 AV2
.001 53 46 18 AV2
.001 53 46 22 AV4
.001 53 46 26 AV5
.00!
53 46 19 AV6
.001 38 47 17 AV3
.001 41 47 18 AV2
.00I 42 47 13 AV2
.001 42 47 19 AV3
.00!
42 47 21 AV4
.001 42 47 13 AV5
.001 42 47 21 AV6
.001 44 47 20 AV2
.001 44 47 16 AV4
.001 46 47 21 AV6
.001 47 47 13 AVI
.001 47 47 19 AV2
.001 47 47 16 AV4
.001 47 47 17 AV5
.00!
48 47 20 AV2
.001 50 47 19 AV1
.001 50 47 40 AV2
.001 50 47 37 AV3
.001 50 47 35 AV4
.001 50 47 18 AV5
.00!
50 47 20 AV6
.001 1 56 47 33 AV4
.001 1 56 47 35 AV5
.001
+
I ROW COL PER LOCN INCH11
-- -+--
-+--
- -+---
+------+
8 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
+
34 48 16 AV6
.001 44 48 16 AV2
.001 44 48 12 AV3
.001 44 48 13 AV4
.001 46 48 14 AV2
.001 48 48 14 AV2
.001 48 48 25 AV3
.001 48 48 34 AV4
.001 48 48 25 AV5
.001 48 48 17 AV6
.001 50 48 24 AV2
.001 50 48 19 AV3
.001 50 48 16 AV4
.001 50 48 25 AV5
.001 50 48 13 AV6
.001 30 49 26 AV2
.001 30 49 33 AV5
.001 30 49 27 AV6
.001 39 49 24 AV4
.001 44 49 12 AV2
.001 44 49 21 AV3
.001 44 49 15 AV4
.001 52 49 18 AV3
.001 33 50 15 AV4
.001 44 50 13 AV1
.001 44 50 15 AV2
.001 44 50 16 AV3
.001 45 50 13 AV1
.001 45 50 19 AV3
.001 45 50 20 AV4
.001
+
I ROW COL PER LOCN INCH11 9
ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
-+-- -
-+-
- - -+-----+
1 45 50 22 AV5
.001 47 50 15 AVI
.001 47 50 20 AV2
.001 47 50 36 AV3
.001 47 50 17 AV5
.001 53 50 22 AV1
.001 53 50 35 AV2
.001 53 50 44 AV3
.001 53 50 25 AV4
.001 53 50 34 AV5
.001 44 51 15 AV2
.001 44 51 24 AV3
.001 44 51 20 AV4
.001 46 51 24 AV2
.001 52 51 18 AVi
.001 25 52 20 AV5
.001 25 52 21 AV6
.001 35 52 18 AV2
.001 35 52 10 AV4
.001 36 52 13 AV4
.001 40 52 15 AV3
.001 40 52 22 AV4
.001 40 52 20 AV5
.001 44 52 16 AV2
.001 47 52 13 AV2
.001 50 52 15 AV1
.001 50 52 18 AV2
.001 37 53 15 AV4
.001
+
I ROW COL PER LOCN INCH11
+
10 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
- -+-------
-+-------+
1 42 53 17 AV5
.001 44 53 31 AV2
.001 44 53 22 AV3
.001 44 53 20 AV4
.001 45 53 18 AV1
.001 45 53 23 AV2
.001 45 53 42 AV3
.001 45 53 26 AV4
.001 46 53 33 AV3
.001 46 53 15 AV4
.001 46 53 14 AV5
.001 46 53 15 AV6
.001 49 53 33 AV4
.001 49 53 31 AV5
.001 40 54 13 AV1
.001 40 54 15 AV2
.001 40 54 13 AV4
.001 42 54 33 AV1
.001 42 54 23 AV2
.001 42 54 24 AV3
.001 42 54 18 AV4
.001 42 54 35 AV5
.001 42 54 24 AV6
.001 44 54 15 AV3
.001 46 54 18 AV4
.001 46 54 21 AV5
.001 47 54 18 AVl
.001 47 54 26 AV2
.001 47 54 15 AV3
.001 47 54 15 AV4
.001 47 54 14 AV5
.001 50 54 28 AV3
.001
+-------------+
I ROW COL PER LOCN INCH11
+
11 ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+.
+
I ROW COL PER LOCN INCH11
+.
+
1 50 54 22 AV4
.001 1 50 54 37 AV5
.001 51 54 17 AV3
.001 51 54 21 AV4
.001 51 54 17 AV5
.001 37 55 15 AV3
.001 38 55 13 AV3
.001 38 55 14 AV4
.001 38 55 13 AV6
.001 40 55 17 AV4
.001 40 55 15 AV5
.001 41 55 13 AV2
.001 43 55 30 AV2
.001 43 55 27 AV3
.00!
43 55 33 AV4
.001 45 55 14 AV2
.001 46 55 21 AV2
.001 46 55 13 AV4
.001 46 55 30 AV5
.001 47 55 10 AV3
.001 51 55 23 AV5
.001 51 55 24 AV6
.001 32 56 13 AV2
.001 36 56 15 AV2
.001 36 56 14 AV3
.001 37 56 24 AV2
.00!
37 56 24 AV3
.001 37 56 16 AV4
.001
+
I ROW COL PER LOCN INCH11
-- -+--
-+--
- -+---
+------
+
12 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+.. +------------------------+
I ROW COL PER LOCN INCH11
+
1 42 56 16 AV3
.00!
1 42 56 18 AV5
.001 44 56 17 AV5
.001 44 56 14 AV6
.001 45 56 21 AV3
.001 46 56 14 AV4
.001 46 56 33 AV5
.001 46 56 17 AV6
.001 48 56 14 AV5
.001 37 57 17 AV3
.001 40 57 17 AV2
.001 40 57 16 AV3
.001 40 57 11 AV5
.001 44 57 17 AV5
.001 45 57 15 AV4
.001 52 57 24 AV2
.001 52 57 18 AV3
.001 53 57 33 AV2
.001 53 57 30 AV3
.001 53 57 19 AV4
.001 36 58 27 AV2
.001 36 58 22 AV3
.001 36 58 12 AV4
.001 37 58 14 AV1
.001 37 58 11 AV2
.001 37 58 12 AV3
.001 37 58 19 AV4
.001 37 58 12 AV5
.001 39 58 18 AV3
.001 I ROW COL PER LOCN INCHlI
+
13 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11 1 39 58 15 AV5
.001 S41 58 18 AVi
.001 41 58 14 AV2
.001 41 58 25 AV3
.001 43 58 18 AV1
.001 43 58 16 AV2
.001 43 58 35 AV3
.001 43 58 36 AV4
.001 46 58 16 AV2
.001 46 58 19 AV3
.001 46 58 21 AV4
.001 46 58 23 AV5
.001 47 58 15 AV1
.001 47 58 25 AV2
.001 47 58 10 AV4
.001 48 58 13 AV3
.001 48 58 17 AV5
.001 49 58 16 AV2
.001 49 58 15 AV3
.001 59 58 12 AV6
.001 37 59 14 AV3
.001 40 59 17 AV2
.001 43 59 16 AV6
.001 47 59 14 AV1
.001 47 59 20 AV2
.001 47 59 13 AV3
.001 47 59 31 AV4
.001 48 59 17 AV2
.001 48 59 17 AV3
.001 48 59 18 AV4
.001
-+-------------
I ROW COL PER LOCN INCH1i 4---------
14 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
+
50 59 21 AV1
.001 50 59 35 AV2
.001 50 59 21 AV3
.001 50 59 23 AV4
.001 50 59 26 AV5
.001 50 59 20 AV6
.001 51 59 17 AV5
.001 51 59 17 AV6
.001 33 60 13 AV2
.001 40 60 20 AV2
.001 40 60 27 AV3
.001 42 60 21 AV2
.001 42 60 17 AV3
.001 42 60 16 AV4
.001 42 60 14 AV5
.001 44 60 21 AV3
.001 44 60 11 AV4
.001 44 60 18 AV5
.001 46 60 10 AV2
.001 46 60 14 AV3
.001 46 60 32 AV5
.001 46 60 18 AV6
.001 47 60 15 AV1
.001 47 60 14 AV2
.001 47 60 26 AV3
.001 48 60 31 AV4
.001 48 60 37 AV5
.001 50 60 16 AV2
.001 50 60 17 AV5
.001 51 60 11 AV6
.001
- -+-
-+------+
I ROW COL PER LOCN INCH11
+
15 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCHI1
+
1 52 60 21 AV4
.001 52 60 20 AV5
.001 36 61 12 AV2
.001 36 61 19 AV3
.001 39 61 13 AV2
.001 39 61 17 AV3
.001 42 61 13 AV2
.001 42 61 12 AV3
.001 43 61 13 AV4
.001 46 61 14 AV1
.001 46 61 12 AV2
.001 46 61 28 AV3
.001 46 61 41 AV4
.001 46 61 16 AV5
.001 46 61 24 AV6
.001 47 61 18 AV2
.001 47 61 14 AV4
.001 48 61 29 AV4
.001 48 61 31 AV5
.001 50 61 21 AV2
.001 50 61 29 AV3
.001 50 61 17 AV5
.001 52 61 18 AV2
.001 55 61 15 AV5
.001 55 61 15 AV6
.00!
34 62 13 AV4
.001 35 62 11 AV2
.001 36 62 14 AV2
.001 36 62 11 AV4
.001
+
I ROW COL PER LOCN INCH11
+
16 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
+---------------------------
39 62 19 AV4
.001 40 62 20 AV2
.001 40 62 29 AV5
.001 41 62 23 AV2
.001 41 62 17 AV3
.001 42 62 36 AV5
.001 42 62 15 AV6
.001 43 62 18 AV2
.001.
43 62 15 AV3
.001 43 62
'22 AV5
.001 43 62 14 AV6
.001 45 62 19 AV2
.001 46 62 11 AVI
.001 46 62 20 AV2
.001 46 62 35 AV3
.001 46 62 14 AV4
.001 46 62 24 AV5
.001 46 62 32 AV6
.001 47 62 20 AV2
.001 47 62 14 AV3
.001 48 62 33 AV2
.001 48 62 14 AV3
.001 48 62 18 AV6
.001 49 62 14 AVi
.001 49 62 33 AV2
.001 49 62 16 AV3
.001 35 63 13 AV2
.001 35 63 15 AV3
.001 37 63 31 AV4
.001
-+--
-+-- - -+--
-+-----+
I ROW COL PER LOCN INCH11
-+---
-+---
-+---
-+-----+
17 ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02 I ROW COL PER LOCN INCH11
+---------------------------
1 38 63 15 AV3
.001 41 63 17 AV3
.00j 41 63 19 AV5
.001 42 63 15 AV2
.001 43 63 27 AV3
.001 43 63 15 AV5
.001 43 63 14 AV6
.001 45 63 23 AV2
.001 45 63 17 AV3
.001 45 63 16 AV4
.001 45 63 28 AV6
.001 46 63 11 AVI
.001 46 63 14 AV3
.001 46 63 21 AV5
.001 47 63 14 AV4
.001 47 63 36 AV5
.001 47 63 13 AV6
.001 48 63 25 AV3
.001 48 63 20 AV5
.001 49 63 25 AV3
.001 50 63 19 AV1
.001 50 63 13 AV2
.001 50 63 24 AV3
.001 53 63 15 AV1
.001 53 63 25 AV2
.001 53 63 28 AV3
.001 53 63 14 AV4
.001 36 64 17 AV3
.001 37 64 30 AV4
.001 37 64 27 AV5
.001
+
I ROW COL PER LOCN INCH11
-+--
-. -+-
-+-
+
18 ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
+.
+
1 37 64 19 AV6
.001 38 64 16 AV2
.001 38 64 25 AV3
.001 38 64 32 AV5
.001 38 64 19 AV6
.001 39 64 14 AV2
.001 41 64 18 AV5
.001 41 64 15 AV6
.001 42 64 22 AV3
.001 43 64 14 AV3
.001 43 64 28 AV4
.001 44 64 12 AV3
.001 44 64 18 AV4
.001 44 64 21 AV5
.001 44 64 17 AV6
.001 45 64 18 AV3
.001 46 64 17 AV1
.001 46 64 16 AV2
.001 46 64 22 AV3
.001 46 64 25 AV4
.001 47 64 16 AV2
.001 47 64 32 AV3
.001 48 64 29 AV2
.001 48 64 24 AV3
.001 48 64 26 AV4
.001 I49 64 24 AV2
.001 49 64 24 AV3
.001 49 64 25 AV4
.001 49 64 17 AV5
.001 51 64 28 AV1
.001
+
I ROW COL PER LOCN INCH11
+
19 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
+
1 51 64 31 AV2
.001 51 64 22 AV3
.001 51 64 45 AV4
.00!
51 64 26 AV5
.001 37 65 13 AV2
.001 37 65 12 AV3
.001 37 65 16 AV4
.001 37 65 18 AV5
.001 37 65 15 AV6
.00!
38 65 14 AV4
.001 38 65 11 AV5
.001 42 65 14 AV2
.001 47 65 11 AV6
.001 51 65 17 AV2
.00I 41 66 16 AV2
.001 44 66 17 AV2
.001 44 66 12 AV3
.001 44 66 10 AV6
.001 46 66 13 AV1
.001 46 66 21 AV3
.001 46 66 27 AV4
.001 46 66 35 AV5
.001 47 66 22 AV2
.001 47 66 25 AV3
.001 47 66 28 AV4
.001 47 66 22 AV5
.001 55 66 12 AV2
.001 38 67 17 AV4
.00 41 67 18 AV3
.001
-+--------
I ROW COL PER LOCN INCH11
-+
-+-
-+------+
20 ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02 I ROW COL PER LOCN INCHI1 1 44 67 15 AV2
.001 1 44 67 12 AV3
.001 1 44 67 16 AV4
.001 1 44 67 16 AV5
.001 46 67 13 AV6
.001 39 68 13 AV3
.001 41 68 11 AV6
.001 42 68 16 AVi
.001 42 68 16 AV2
.001 42 68 14 AV3
.001 42 68 14 AV4
.001 42 68 14 AV6
.001 45 68 21 AV5
.001 50 68 22 AV2
.001 50 68 30 AV3
.001 50 68 15 AV4
.001 42 69 13 AV3
.001 44 69 10 AV2
.001 44 69 17 AV3
.001 45 69 14 AVi
.001 45 69 12 AV2
.001 45 69 26 AV4
.001 45 69 18 AV5
.001 45 69 16 AV6
.001 50 69 10 AVi
.001 50 69 16 AV2
.001 50 69 25 AV3
.001 51 69 16 AV2
.001 44 70 18 AV2
.001 44 70 12 AV4
.001
+
I ROW COL PER LOCN INCHI1
+
21 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02 I ROW COL PER LOCN INCH11
+
47 70 12 AV4
.001 52 70 11 AV6
.001 54 70 18 AVI
.001 54 70 18 AV2
.001 36 71 12 AV4
.001 36 71 12 AV5
.001 40 71 12 AV6
.001 41 71 19 AV2
.001 41 71 15 AV3
.001 48 71 14 AV6
.001 49 71 21 AV2
.001 49 71 28 AV3
.001 49 71 14 AV4
.001 37 72 13 AV2
.001 37 72 26 AV3
.001 37 72 25 AV5
.001 37 72 15 AV6
.001 40 72 12 AVi
.001 40 72 23 AV2
.001 40 72 17 AV3
.001 40 72 23 AV5
.001 44 72 12 AV2
.001 44 72 17 AV3
.001 44 72 21 AV5
.001 50 72 16 AV2
.001 50 72 12 AV3
.001 50 72 13 AV4
.001 50 72 33 AV5
.001 50 72 28 AV6
.001
+
I ROW COL PER LOCN INCH11 22 ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02 I ROW COL PER LOCN INCH11 1 52 72 16 AV5
.001 40 73 18 AV5
.001 41 73 11 AV3
.001 44 73 20 AV2
.001 44 73 19 AV4
.001 44 73 19 AV5
.001 45 73 15 AV4
.001 45 73 35 AV5
.001 49 73 17 AV2
.001 49 73 16 AV3
.001 49 73 28 AV4
.001 49 73 18 AV5
.001 51 73 21 AVI
.001 51 73 17 AV2
.001 51 73 15 AV3
.001 37 74 20 AV3
.001 37 74 20 AV4
.001 37 74 18 AV5
.001 37 74 17 AV6
.001 39 74 20 AV4
.001 39 74 12 AV5
.001 42 74 19 AV2
.001 42 74 17 AV3
.001 43 74 10 AV4
.001 44 74 16 AV2
.001 44 74 39 AV4
.001 44 74 19 AV6
.001 45 74 14 AV2
.001 45 74 23 AV3
.001 45 74 41 AV4
.001 I ROW COL PER LOCN INCH11 23 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
+
1 45 74 42 AV5
.001 1 45 74 25 AV6
.001 48 74 17 AV4
.001 50 74 27 AV2
.001 50 74 12 AV3
.001 50 74 20 AV5
.001 51 74 17 AV3
.001 51 74 23 AV5
.001 55 74 25 AV4
.001 55 74 27 AV5
.001 55 74 24 AV6
.001 37 75 13 AV3
.001 46 75 29 AV2
.001 46 75 21 AV3
.001 46 75 16 AV4
.001 47 75 15 AV6
.001 50 75 19 AV3
.001 1 50 75 26 AV4
.001 51 75 20 AV2
.001 53 75 19 AV4
.001 53 75 23 AV5
.001 53 75 21 AV6
.001 41 76 16 AV6
.001 44 76 13 AV3
.001 44 76 18 AV4
.001 44 76 16 AV5
.001 45 76 14 AV5
.001 44 77 12 AV2
.001
-+--
- -+--
- -+---
-+-----+
I ROW COL PER LOCN INCH11
-- -+--
-+--
- -+---
+------+
24 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
+
1 44 77 19 AV3
.001 1 44 77 12 AV4
.001 44 77 13 AV5
.001 45 77 15 AV3
.001 45 77 15 AV4
.001 48 77 14 AV3
.001 48 77 15 AV4
.001 46 78 12 AV2
.001 47 78 10 AV5
.001 41 79 11 AV2
.001 41 79 12 AV3
.001 41 79 15 AV4
.001 44 79 17 AV2
.001 44 79 19 AV3
.001 44 79 35 AV4
.001 44 79 35 AV5
.001 44 79 30 AV6
.001 47 79 15 AV3
.001 47 79 28 AV4
.001 47 79 24 AV5
.001 47 79 16 AV6
.001 48 79 14 AV5
.001 50 79 14 AV2
.001 50 79 17 AV4
.001 50 79 34 AV5
.001 50 79 13 AV6
.001 37 80 12 AV3
.001 37 80 10 AV4
.001 1 37 80 18 AV5
.001 43 80 16 AV2
.001 4---
I ROW COL PER LOCN INCHI1
+
25 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCH11
-+-------+
1 44 80 14 AV3
.001 45 80 12 AV2
.001 45 80 16 AV3
.00!
45 80 21 AV4
.001 45 80 21 AV5
.001 45 80 11 AV6
.001 47 80 30 AV4
.001 47 80 12 AV5
.001 47 80 15 AV6
.001 35 81 13 AVi
.001 36 81 10 AVi
.001 36 81 13 AV4
.001 36 81 19 AV5
.001 40 81 34 AV2
.001 40 81 27 AV3
.001 40 81 35 AV4
.001 40 81 40 AV5
.001 40 81 17 AV6
.001 44 81 18 AV2
.001 44 81 15 AV3
.001 44 81 14 AV6
.001 45 81 11 AV4
.00!
46 81 14 AV3
.001 47 81 15 AV2
.00!
47 81 24 AV3
.001 47 81 27 AV4
.001 47 81 11 AV6
.001 50 81 15 AV3
.001 37 82 19 AV3
.001 1 47 82 10 AV3
.001 I ROW COL PER LOCN INCH11 26 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+--------
I ROW COL PER LOCN INCH11
+
1 47 82 16 AV4
.001 47 82 11 AV6
.001 50 82 11 AV2
.001 44 83 11 AV3
.001 44 83 14 AV4
.001 45 83 17 AV3
.001 45 83 12 AV4
.001 45 83 15 AV5
.001 48 83 15 AV2
.001 44 84 11 AV6
.001 46 84 13 AV3
.001 47 84 13 AV4
.001 47 84 14 AV5
.001 50 84 13 AV3
.001 39 85 15 AV2
.001 39 85 17 AV5
.001 44 85 13 AV3
.001 44 85 15 AV5
.001 45 85 14 AV2
.001 45 85 18 AV4
.001 45 85 21 AV5
.001 50 85 19 AV3
.001 50 85 17 AV5
.001 51 85 12 AV2
.001 51 85 25 AV3
.001 51 85 36 AV4
.001 51 85 24 AV5
.001 51 85 13 AV6
.001
+
I ROW COL PER LOCN INCH11
-+-
-+------
+
27 ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
+
I ROW COL PER LOCN INCHI1
+
1 37 86 17 AV4
.001 44 86 15 AV3
.001 44 86 19 AV4
.001 44 86 17 AV5
.001 50 86 24 AV3
.001 50 86 15 AV4
.001 50 86 16 AV5
.001 38 87 15 AV6
.001 44 87 13 AV4
.001 44 87 19 AV5
.001 47 87 14 AV2
.001 48 87 12 AV4
.001 52 87 11 AV4
.001 52 87 12 AV5
.001 52 87 10 AV6
.001 54 87 16 AV1
.001 54 87 13 AV6
.001 42 88 15 AV3
.001 50 88 21 AV3
.001 50 88 10 AV4
.001 50 88 20 AV5
.001 21 89 13 AV2
.001 36 89 11 AV4
.001 45 89 20 AV4
.001 45 89 12 AV5
.001 52 89 24 AV5
.001 23 90 19 AV6
.001
+
I ROW COL PER LOCN INCH11
+
28 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCHI1 45 90 17 AV3
.001 45 90 13 AV6
.001 49 90 17 AV2
.001 50 90 19 AV3
.001 50 90 20 AV4
.00!
50 90 19 AV5
.001 53 90 15 AV5
.001 53 90 20 AV6
.001 44 91 11 AV3
.001 44 91 16 AV6
.001 47 91 10 AV4
.001 47 91 12 AV5
.001 47 91 12 AV6
.001 48 91 12 AV3
.001 50 91 11 AV5
.001 50 91 18 AV6
.001 1
92 13 FBC
.351 45 92 16 AV4
.001 45 92 10 AV5
.001 45 92 11 AV6
.00!
40 93 10 AV5
.001 40 93 13 AV6
.001 44 93 14 AV5
.001 44 94 11 AV5
.001 46 94 15 AV2
.001 46 94 26 AV3
.001 46 94 20 AV4
.001 46 94 13 AV5
.001 I ROW COL PER LOCN INCHI1 29 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCHI1
+
46 95 16 AV2
.001 46 95 16 AV3
.001 46 95 14 AV4
.00!
46 95 12 AV5
.001 47 95 15 AV4
.001 47 95 13 AV5
.001 47 95 10 AV6
.001 48 95 14 AV4
.001 48 95 26 AV6
.001 49 95 10 AV3
.001 49 95 24 AV5
.001 49 95 17 AV6
.001 38 96 14 AV6
.001 45 96 21 AV3
.001 45 96 18 AV4
.001 45 96 13 AV6
.001 46 96 22 AV2
.001 46 96 35 AV3
.001 46 96 12 AV4
.001 46 96 11 AV5
.001 47 96 18 AV3
.001 47 96 28 AV4
.001 47 96 28 AV5
.001 47 96 19 AV6
.001 48 96 25 AV6
.001 49 96 28 AV6
.001 47 97 28 AV4
.001 47 97 35 AV5
.001 47 97 19 AV6
.001 41 98 16 AV5
.001
-+--
-+-
+- ---
+-----+
I ROW COL PER LOCN INCH11
+
ST Max
SG -
B Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+.
+
I ROW COL PER LOCN INCHI1
+-----------------------------i 44 98 19 AV5
.001 45 98 20 AV3
.001 45 98 32 AV5
.001 45 98 18 AV6
.001 46 98 20 AV2
.001 46 98 28 AV4
.001 46 98 33 AV5
.001 48 98 33 AV5
.001 48 98 33 AV6
.001 43 99 18 AV3
.001 43 99 13 AV4
.001 43 99 25 AV5
.001 43 99 12 AV6
.001 45 99 16 AV3
.001 45 99 13 AV4
.001 45 99 21 AV5
.001 46 99 14 AV4
.001 46 99 17 AV6
.001 43 100 25 AV3
.001 43 100 30 AV5
.001 43 100 14 AV6
.001 44 100 27 AV5
.001 44 100 42 AV6
.001 45 100 14 AV2
.001 45 100 23 AV5
.001 45 100 13 AV6
.001 39 101 14 AV5
.001 1 41 101 16 AV6
.001 42 101 20 AV5
.001 I ROW COL PER LOCN INCH11
-- -+--
- -+--
- -+---
+-------
31 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+
I ROW COL PER LOCN INCHI1
+
42 101 21 AV6
.001 43 101 15 AV5
.001 43 101 19 AV6
.001 44 101 17 AV3
.001 44 101 29 AV4
.001 44 101 34 AV5
.001 44 101 14 AV6
.001 40 102 18 AV5
.00 41 102 22 AV4
.001 43 102 18 AV2
.001 43 102 19 AV4
.001 40 103 13 AV5
.001 41 103 16 AV6
.001 42 103 19 AV5
.001 42 103 15 AV6
.001 43 103 17 AV3
.001 43 103 18 AV5
.001 39 104 13 AV5
.001 39 104 15 AV6
.001 40 104 14 AV4
.001 40 104 20 AV6
.001 41 104 24 AV5
.001 41 104 36 AV6
.001 37 105 11 AV3
.001 37 105 14 AV5
.001 37 105 16 AV6
.001 38 105 16 AV2
.001 38 105 22 AV3
.001
+
I ROW COL PER LOCN INCH11
+
32 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02
+---------------------------
I ROW COL PER LOCN INCH11
- -+-
- -+-----+
1 38 105 22 AV6
.001 I39 105 17 AV4
.00 39 105 10 AV5
.001 39 105 22 AV6
.001 41 105 23 AV6
.001 36 106 12 AV6
.001 38 107 12 AV5
.001 38 107 16 AV6
.001 35 108 16 AV5
.001 33 109 11 AV6
.001 35 109 13 AV6
.001 36 109 11 AV2
.001 36 109 23 AV4
.001 36 109 14 AV5
.001 33 110 17 AV2
.001 33 110 20 AV5
.00!
36 110 32 7C
-. 451 36 110 23 AV6
.001 33 111 15 AV2
.001 33 111 19 AV5
.001 33 111 16 AV6
.001 34 111 12 AV6
.001 28 113 13 AV2
.00!
28 113 18 AV5
.001 26 115 20 AV2
.001 26 115 15 AV5
.001 28 115 16 AV5
.001
+
I ROW COL PER LOCN INCH11
+
33 ST Max
SG B
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 17:58:02 I ROW COL PER LOCN 4-
--- I---
-N
+
INCHill
-~+
I I
I 26 116 14 AV2
.001 I26 116 18 AV5
.001
+
I ROW COL PER LOCN INCH11
- -+-
-+--
Tubes: 428 Records: 962 34 ST Max to ET 11-0008 Steam Generator C Service-Induced Indications (23 pages)
SG -
C Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04 I ROW COL PER LOCN INCH11
-+--
-+--
-+---
-+-----+
1 4
2 TSC 14.721 16 5
7 TSH
.341 1
6 9
TSC 14.921 1
8 5
TSC 15.091 28 8
12 AV2
.001 1
9 8
TSC 15.471 1
10 14 TSC 15.251 1
11 9
TSC 15.261 1
12 8
TSC 15.371 32 12 10 AV4
.001 1
13 13 TSC 15.611 33 13 11 AVi 001 33 13 14 AV4
.001 1
14 13 TSC 15.361 33 14 12 AV3
.001 33 14 15 AV4
.001 33 14 17 AV6
.001 34 14 18 AV1
.001 34 14 13 AV3
.001 34 14 22 AV4
.001 34 14 11 AV6
.001 35 14 25 AV3
.001 35 14 23 AV4
.001 1
15 13 TSC 15.531 35 15 37 AV2
.001
+
I ROW COL PER LOCN INCH11
+
1 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04 I ROW COL PER LOCN INCH11
-+--
- -+--
-+--
-+-----
1 35 15 20 AV4
.001 1 35 15 14 AV6
.001 37 15 18 AV2
.001 37 15 21 AV4
.001 1
16 15 TSC 15.481 34 16 19 AV4
.001 35 16 11 AVi
.001 35 16 17 AV2
.001 35 16 17 AV4
.001 35 16 14 AV6
.001 1
17 12 TSC 15.401 1
18 17 TSC 15.571 34 18 13 AV4
.001 34 18 12 AV5
.001 1
19 11 TSC 15.741 38 19 26 TSC 9.201 39 19 11 TSC 8.691 40 19 8
TSC 7.821 1
20 11 TSC 15.631 38 20 23 AV2
.001 38 20 14 AV3
.001 38 20 20 AV4
.001 36 21 11 AV2
.001 36 21 15 AV3
.001 39 21 13 AV2
.001 39 21 18 AV3
.001 39 21 13 AV6
.001
+
I ROW COL PER LOCN INCH11
-+--
-+--
- -+--
-+-----+
2 ST Max
SG -
C Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCHI1
-+---
-+-
+
39 22 12 AV4
.001 40 22 19 AV2
.001 42 22 20 AV4
.001 42 22 15 AV5
.001 35 24 21 AV6
.001 1
25 7
3C 23.651 1
25 8
3C 24.611 46 25 13 AV2
.001 47 25 18 AV2
.001 47 25 11 AV4
.001 38 26 11 AV2
.001 38 26 12 AV3
.001 36 27 10 AV3
.001 36 27 12 AV4
.001 38 27 15 AV2
.001 38 27 14 AV3
.001 39 27 22 AV4
.001 39 27 19 AV5
.001 34 28 11 AV3
.001 38 28 11 AV3
.001 38 28 18 AV4
.001 38 28 15 AV5
.001 38 28 13 AV6
.001 42 28 16 AV4
.001 39 29 12 AV3
.001 39 29 16 AV5
.001
-+-
-+- -+------
I ROW COL PER LOCN INCH11
+
3 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
+
1 50 29 11 AVI
.001 39 30 16 AV5
.001 34 31 14 AV4
.001 34 31 12 AV5
.001 38 31 12 AV3
.001 1
32 13 FBC
-. 081 39 32 15 AV4
.001 38 33 11 AV2
.001 38 33 15 AV3
.001 38 33 11 AV4
.001 44 33 13 AV3
.001 44 33 28 AV4
.001 44 33 21 AV5
.001 52 35 11 AV2
.001 28 36 14 AV5
.001 40 36 11 AV1
.001 40 36 13 AV3
.001 27 37 17 AV6
.001 33 37 11 AV1
.001 33 37 13 AV5
.001 37 37 12 AV1
.001 37 37 19 AV3
.001 37 37 18 AV4
.001 37 37 14 AV5
.001 38 37 14 AV3
.001 40 37 11 AV1
.001 1 40 37 11 AV3
.001
+ ----.
+
I ROW COL PER LOCN INCH11 4
ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
-+--
- -+--
-+--
-+-----+
43 37 21 TSH
.521 54 37 12 AV2
.001 28 39 22 AV1
.001 28 39 24 AV2
.001 28 39 14 AV5
.001 28 39 24 AV6
.001 34 39 13 AV2
.001 45 39 11 AVI
.001 45 39 19 AV2
.001 45 39 24 AV3
.001 45 39 12 AV4
.001 19 40 12 AV6
.001 34 40 17 AV2
.001 1 34 40 18 AV3
.001 34 40 11 AV4
.001 38 40 19 AVI
.001 38 40 13 AV2
.001 38 40 17 AV3
.001 38 40 16 AV4
.001 38 40 17 AV5
.001 42 40 18 AV1
.001 42 40 12 AV2
.001 42 40 24 AV3
.001 42 40 28 AV4
.001 42 40 17 AV5
.001 42 40 14 AV6
.001 51 40 11 AV3
.001 51 40 31 AV4
.001 51 40 16 AV5
.001 51 40 20 AV6
.001 24 41 12 AV6
.001
+
I ROW COL PER LOCN INCH11
+
5 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04 I ROW COL PER LOCN INCHI1 26 41 14 AV2
.001 26 41 12 AV5
.001 28 41 18 AV2
.001 34 41 18 AV3
.001 34 41 10 AV4
.001 40 41 19 AV3
.001 40 41 25 AV4
.001 40 41 25 AV5
.001 35 42 10 AVi
.001 38 42 10 AV3
.001 29 43 15 AV5
.001 36 43 13 AVI
.001 42 43 11 AVI
.001 42 43 14 AV2
.001 42 43 17 AV3
.001 45 43 11 AVI
.001 45 43 10 AV2
.001 27 44 18 AV2
.001 27 44 16 AV5
.001 31 44 16 AV2
.001 31 44 13 AV5
.001 31 44 16 AV6
.001 38 44 13 AV2
.001 39 44 16 AV2
.001 48 44 10 AVI
.001 39 45 13 AVI
.001
- - -+-
+
I ROW COL PER LOCN INCH11 6
ST Max
SG -
C Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04 I ROW COL PER LOCN INCH11 1 39 45 12 AV3
.001 39 45 33 AV4
.001 39 45 27 AV5
.001 39 45 17 AV6
.001 49 46 18 AV1
.001 49 46 15 AV2
.001 58 46 12 AV4
.001 28 47 14 AV5
.001 35 47 18 AV2
.001 35 47 12 AV3
.001 35 47 15 AV4
.001 35 47 14 AV5
.001 44 47 18 AVI
.001 44 47 14 AV2
.001 44 47 16 AV3
.001 30 48 11 AV2
.001 30 48 11 AV5
.001 30 48 15 AV6
.001 31 48 18 AVI
.001 31 48 25 AV2
.001 31 48 36 AV5
.001 31 48 27 AV6
.001 34 48 11 AV2
.001 35 48 14 AV2
.001 45 48 11 AV3
.001 45 48 26 AV4
.001 45 48 32 AV5
.001 45 48 14 AV6
.001 31 49 15 AV5
.001 33 49 16 AVI
.001
+
I ROW COL PER LOCN INCH11
-- -+--
- -+--
- -+-
+
7 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
- -+-
+
1 33 49 35 AV2
.001 1 33 49 30 AV3
.001 33 49 13 AV4
.001 33 49 15 AV6
.001 44 49 13 AV2
.001 27 50 16 AV5
.001 27 50 13 AV6
.001 39 50 10 AV3
.001 39 50 15 AV4
.001 39 50 19 AV5
.001 39 50 13 AV6
.001 49 50 20 AV2
.001 26 51 12 AV5
.001 27 51 11 AV2
.001 27 51 16 AV5
.001 29 51 12 AV5
.001 56 51 20 TSH
.161 29 52 21 AV2
.001 29 52 21 AV5
.001 29 52 17 AV6
.001 24 53 13 AV2
.001 24 53 12 AV5
.001 19 54 15 AVi
.001 19 54 13 AV6
.001 24 54 12 AV2
.001 38 54 17 AVi
.001 38 54 22 AV2
.001 38 54 28 AV3
.001 38 54 26 AV4
.001
+
I ROW COL PER LOCN.
INCH11
+
8 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
+.
+
1 38 54 22 AV5
.00@
45 54 12 AV5
.001 28 55 14 AV2
.001 29 55 16 AV2
.001 31 55 18 AV2
.001 45 55 17 AV2
.001 45 55 20 AV3
.001 45 55 22 AV4
.001 45 55 24 AV5
.001 26 56 11 AV2
.001 26 56 11 AV5
.001 38 56 11 AV1
.001 38 56 14 AV2
.001 26 57 13 AV2
.001 26 57 19 AV5
.001 27 57 17 AV2
.001 29 57 17 AV2
.001 33 57 15 AV2
.00!
44 57 23 AV2
.001 44 57 38 AV3
.001 44 57 30 AV4
.001 44 57 22 AV5
.001 44 57 24 AV6
.001 45 57 18 AV2
.001 46 57 11 AV1
.001 46 57 27 AV2
.001 46 57 30 AV3
.001 46 57 27 AV4
.001
+-
I ROW COL PER LOCN INCH11
-+-- -- -+-- -- -+-
+
9 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04 I ROW COL PER LOCN INCH11 1 46 57 16 AV5
.001 47 57 21 AV2
.001 47 57 13 AV3
.001 24 58 15 AV5
.001 26 58 14 AV2
.001 26 58 16 AV5
.001 27 58 15 AV2
.001 27 58 14 AV5
.001 27 58 12 AV6
.00!
37 58 21 AV2
.001 37 58 14 AV3
.001 37 58 21 AV5
.001 46 58 15 AV4
.001 46 58 12 TSH
.391 30 59 17 AV2
.001 30 59 15 AV5
.001 30 59 12 AV6
.001 33 59 28 AV2
.001 33 59 15 AV3
.001 33 59 18 AV4
.001 44 59 17 AV2
.001 44 59 19 AV3
.001 44 59 16 AV4
.001 44 59 14 AV5
.001 44 59 18 AV6
.001 46 59 12 AVi
.001 46 59 21 AV2
.001 29 60 14 AV2
.001 30 60 11 AV2
.001 1 30 60 14 AV5
.001
+
I ROW COL PER LOCN INCH11
+
10 ST Max
SG -
C Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04 I ROW COL PER LOCN INCH11
+
1 34 60 18 AV2
.001 1 34 60 18 AV3
.001 1 34 60 12 AV5
.001 49 60 14 AV2
.001 49 60 16 AV4
.001 49 60 13 AV5
.001 49 60 21 AV6
.001 50 60 13 AVI
.001 50 60 20 AV2
.001 50 60 20 AV3
.001 52 60 21 AV2
.001 45 61 15 AV2
.001 30 62 16 AV2
.001 30 62 13 AV5
.001 50 62 16 AVI
.001 50 62 23 AV2
.001 50 62 28 AV3
.001 50 62 25 AV4
.001 50 62 24 AV5
.001 32 63 12 TSH
.461 50 63 32 AV2
.001 50 63 29 AV3
.001 50 63 28 AV4
.001 50 63 11 AV5
.001 42 64 11 AV5
.001 44 64 10 AV2
.001 45 64 10 AV1
.001 45 64 20 AV2
.001 45 64 23 AV3
.001 45 64 15 AV4
.001
+
I ROW COL PER LOCN INCHI1
+-------------+
11 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
+
1 45 64 11 AV5
.001 47 64 21 AV1
.001 47 64 34 AV2
.001 47 64 17 AV3
.001 50 64 11 AV1
.001 50 64 31 AV2
.001 50 64 34 AV3
.001 50 64 18 AV4
.001 50 64 17 AV5
.001 50 64 10 AV6
.001 35 65 17 AV2
.001 45 65 16 AV1
.001 45 65 32 AV2
.001 45 65 30 AV3
.001 45 65 25 AV4
.001 45 65 10 AV5
.001 47 65 16 AV2
.001 47 65 11 AV3
.001 27 66 14 AV2
.001 35 66 15 AV2
.001 35 66 30 AV4
.001 35 66 17 AV5
.001 37 66 12 AV1
.001 44 66 13 AV2
.001 49 66 10 AV1
.001 49 66 14 AV2
.001 49 66 13 AV3
.001 50 66 11 AV1
.001 50 66 25 AV2
.001 50 66 11 AV4
.001
-+--
-+-
+- ---
+-----+
I ROW COL PER LOCN INCH11
+
12 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
+
1 52 66 10 AV2
.001 45 67 14 AV3
.001 45 67 23 AV4
.001 45 67 17 AV5
.001 47 67 12 AV2
.001 19 68 16 AVi
.001 30 68 13 AV2
.001 44 68 26 AV1
.001 44 68 23 AV2
.001 44 68 23 AV3
.001 44 68 23 AV4
.001 44 68 26 AV5
.001 44 68 32 AV6
.001 47 68 14 AV1
.001 47 68 20 AV2
.001 47 68 12 AV5
.001 49 68 16 AV2
.001 50 68 31 AV1
.001 50 68 32 AV2
.001 50 68 29 AV3
.001 50 68 17 AV4
.001 50 68 12 AV5
.001 50 68 25 AV6
.001 45 69 30 AV1
.001 45 69 31 AV2
.001 45 69 20 AV3
.001 45 69 41 AV4
.001 45 69 23 AV5
.001 50 69 11 AVi
.001 50 69 22 AV2
.001 50 69 18 AV3
.001 50 69 14 AV4
.001
+
I ROW COL PER LOCN INCH11
-+---
-+--
- -+-
-+------+
13 ST Max
SG -
C Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+--------------------------
I ROW COL PER LOCN INCHI1 52 69 20 AV2
.001 40 70 17 AV3
.001 40 70 15 AV4
.001 44 70 12 AV2
.001 44 70 18 AV3
.001 44 70 21 AV4
.001 45 71 19 AV3
.001 33 73 16 AV2
.001 45 74 13 AV5
.001 49 74 13 AVi
.001 49 74 14 AV2
.001 29 75 14 AV2
.001 43 75 26 AV2
.001 43 75 21 AV3
.001 43 75 23 AV4
.001 43 75 13 AV5
.001 43 75 30 AV6
.001 49 75 34 AV3
.001 49 75 42 AV4
.001 49 75 26 AV5
.001 49 75 22 AV6
.001 43 76 12 AV2
.001 51 76 25 AV3
.001 51 76 18 AV4
.001 35 77 21 AV2
.001 35 77 10 AV4
.001 35 77 18 AV6
.001 39 77 12 AV3
.001
+----------------+
I ROW COL PER LOCN INCH11
+
14 ST Max
SG -
C Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
+
1 39 77 11 AV4
.001 39 77 14 AV5
.001 39 77 14 AV6
.001 45 77 20 AV2
.001 45 77 36 AV3
.001 45 77 28 AV4
.001 45 77 14 AV5
.001 55 77 15 AVI
.001 29 78 13 AV2
.001 35 78 16 AV2
.001 35 78 24 AV3
.001 35 78 29 AV4
.001 35 78 22 AV5
.001 35 78 15 AV6
.001 33 80 18 AV6
.001 34 80 12 AV2
.001 38 80 11 AV6
.001 28 81 18 AV2
.001 28 81 20 AV5
.001 29 81 16 AVi
.001 29 81 12 AV2
.001 29 81 13 AV5
.001 36 81 10 AVI
.001 36 81 21 AV2
.001 36 81 20 AV3
.001 36 81 20 AV4
.001 36 81 12 AV5
.001 36 81 20 AV6
.001 40 81 10 AV2
.001 41 81 14 AV4
.001
+
I ROW COL PER LOCN INCH11
-+--
-+--
- -+--
-+-----+
15 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
+----
+
16 82 18 AVI
.001 16 82 13 AV6
.001 38 83 12 AV3
.001 33 84 12 AV4
.001 33 84 14 AV6
.001 40 84 25 AV2
.001 40 84 12 AV4
.001 46 84 29 AV3
.001 46 84 27 AV4
.001 46 84 22 AV5
.001 36 85 12 AVi
.001 36 85 20 AV2
.001 36 85 15 AV3
.001 36 85 30 AV4
.001 38 85 16 AV4
.001 38 85 18 AV5
.001 35 86 20 AV2
.001 35 86 20 AV5
.001 44 86 21 AV4
.001 44 86 17 AV5
.001 1
87 19 TSH 2.871 30 87 14 AV2
.001 35 87 10 AV1
.001 35 87 19 AV2
.001 35 87 17 AV5
.001 43 87 16 AV2
.001 43 87 21 AV3
.001 43 87 20 AV5
.001
+
I ROW COL PER LOCN INCH11
+
16 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
-+-
- --------+
1 28 88 11 AVI
.001 28 88 13 AV2
.001 28 88 15 AV6
.001 36 88 14 AV2
.001 39 88 14 AV2
.001 39 88 14 AV5
.001 39 88 30 AV6
.001 40 88 13 AV6
.001 28 89 10 AV6
.001 33 89 10 AV6
.001 35 89 12 AV2
.001 38 89 14 AV6
.001 1
90 11 FBC
-.271 22 90 10 AV2
.001 1
91 12 FBC
-.211 35 91 17 AV3
.001 36 91 13 AV2
.001 36 91 10 AV4
.001 36 91 12 AV5
.001 39 91 12 AV3
.001 45 91 15 AV3
.001 45 91 22 AV4
.001 45 91 32 AV6
.001 47 91 14 AV2
.001 47 91 12 AV3
.001 47 91 12 AV4
.001 47 91 25 AV6
.001
+
I ROW COL PER LOCN INCH11
+
17 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
+- --
1 92 16 FBC
-. 321 8
92 15 TSH 1.291 30 92 27 AV2
.001 30 92 22 AV5
.001 30 92 17 AV6
.001 35 92 18 AV2
.001 35 92 15 AV3
.001 38 92 21 AV3
.001 38 92 12 AV6
.001 39 92 13 AV3
.001 39 92 13 AV4
.001 39 92 15 AV5
.001 39 92 15 AV6
.001
.46 92 11 AVi
.001 46 92 26 AV3
.001 1
93 15 FBC
-. 371 45 93 11 AV3
.001 45 93 21 AV4
.001 45 93 12 AV6
.001 36 94 15 AV3
.001 38 94 12 AV3
.00!
38 94 14 AV5
.00!
38 94 10 AV6
.001 39 94 10 AV3
.001 39 94 25 AV4
.001 39 94 19 AV5
.001 39 94 11 AV6
.001 1 48 94 10 AV2
.001 1 48 94 18 AV3
.001 I
I ROW COL PER LOCN INCH11 18 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+-------------+
I ROW COL PER LOCN INCH11 48 94..
+
22..-+
AV4-
+--+
1 48 94 22 AV4
.001 1 48 94 24 AV5
.001 148 94 17 AV6
.001 35 95 10 AV6
.001 37 95 14 AV2
.001 37 95 10 AV3
.001 38 95 15 AV3
.001 39 95 12 AV3
.001 39 95 15 AV4
.001 48 95 20 AV4
.001 48 95 12 AV6
.001 39 96 12 AV4
.001 44 96 17 AV2
.001 44 96 25 AV3
.001 44 96 21 AV4
.001 44 96 17 AV5
.001 48 96 15 AV3
.001 48 96 20 AV5
.001 39 97 14 AV3
.001 39 97 10 AV6
.001 40 97 13 AV3
.001 40 97 12 AV5
.001 40 97 10 AV6
.001 21 98 14 AV6
.001 33 98 13 AV4
.001 34 98 14 AV4
.001 36 98 16 AV4
.001
+
I ROW COL PER LOCN INCHll
+
19 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
+
I ROW COL PER LOCN INCHI1
-+-----+
1 39 98 17 AV4
.001 48 98 20 AV3
.001 48 98 17 AV4
.001 48 98 18 AV5
.001 48 98 23 AV6
.001 35 99 12 AVI
.001 35 99 11 AV6
.001 39 99 11 AVI
.001 39 99 14 AV4
.001 39 99 11 AV5
.001 39 99 10 AV6
.001 40 99 13 AVi
.001 40 99 13 AV3
.001 40 99 15 AV4
.001 40 99 26 AV5
.001 40 99 12 AV6
.001 35 100 15 AV2
.001 35 100 12 AV6
.001 36 100 11 AV2
.001 36 100 17 AV3
.001 36 100 14 AV6
.001 39 100 14 AV3
.001 39 100 18 AV4
.001 44 100 26 AV2
.001 44 100 16 AV4
.001 44 100 14 AV5
.001 35 101 10 AV5
.001 35 101 10 AV6
.001 36 101 20 AV3
.001 36 101 10 AV4
.001 37 101 12 AV6
.001
+
I ROW COL PER LOCN INCH11
+
20 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
+
38 101 16 AV2
.001 38 101 10 AV4
.001 38 101 14 AV6
.001 39 101 17 AV4
.001 39 101 21 AV6
.001 40 101 12 AVI
.001 40 101 17 AV2
.001 40 101 31 AV3
.001 40 101 42 AV4
.001 40 101 20 AV5
.001 40 101 14 AV6
.001 41 101 14 TSH
.241 135 102 18 AV2
.00 35 102 12 AV3
.001 35 102 14 AV6
.001 41 102 24 TSH
.301 42 102 16 TSH
.281 34 103 14 AV4
.001 34 103 11 AV6
.001 38 103 17 AV3
.001 38 103 10 AV4
.001 38 103 11 AV6
.001 41 103 13 AV4
.001 41 103 15 AV5
.001 30 105 18 AV5
.001 35 105 11 AV5
.001 35 105 10 AV6
.001 40 105 15 AV6
.001
+
I ROW COL PER LOCN INCH11 21 ST Max
SG -
C Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCHI1
+
1 41 105 13 AV5
.001 41 105 13 AV6
.001 35 106 18 AV4
.001 35 106 14 AV6
.001 39 106 11 AV6
.001 40 106 18 AV6
.001 32 107 14 AV2
.001 32 107 10 AV5
.001 32 107 21 AV6
.001 33 107 12 AV4
.00!
33 107 14 AV6
.001 38 107 20 AV2
.001 38 107 31 AV3
.001 38 107 23 AV4
.001 38 107 20 AV5
.001 38 107 18 AV6
.001 39 107 16 AV5
.001 39 107 17 AV6
.001 33 108 20 AV3
.001 33 108 17 AV4
.001 35 108 17 AV2
.001 35 108 17 AV6
.001 37 108 13 AV3
.001 37 108 23 AV5
.001 37 108 11 AV6
.001 34 109 14 AV2
.001 34 109 12 AV3
.001 34 109 20 AV4
.001 34 109 16 AV5
.001 34 109 12 AV6
.001
+
I ROW COL PER LOCN INCH11
+
22 ST Max
SG C
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:00:04
+
I ROW COL PER LOCN INCH11
- -+--
-- - -+-----
-+
1 35 109 22 AV3
.001 35 109 33 AV4
.001 35 109 30 AV5
.001 33 110 13 AVi
.001 33 110 16 AV5
.001 36 110 12 AV3
.001 36 110 12 AV5
.001 36 110 14 AV6
.001 30 112 13 AV2
.001 30 112 14 AV5
.001 26 113 12 AV2
.001 28 113 19 AV5
.001 28 114 24 AV2
.001 28 114 17 AV5
.001 28 114 14 AV6
.001 23
.116 11 AV2
.001 12 121 9
TSH
.481
- -+-
-+------+
I ROW COL PER LOCN INCH11
+
Tubes: 304 Records: 646 23 ST Max to ET 11-0008 Steam Generator D Service-Induced Indications (35 pages)
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
27 8
13 AV2
.001 1 27 8
18 AV5
.001 29 10 14 AVI
.001 29 10 16 AV2
.001 29 10 25 AV5
.001 30 10 14 AVI
.001 30 10 17 AV2
.001 30 10 25 AV5
.001 32 11 15 AV2
.001 32 11 17 AV6
.001 33 11 17 AV2
.00!
33 11 16 AV5
.001 33 11 23 AV6
.00!
31 12 12 AV5
.001 32 12 20 AV5
.001 32 12 14 AV6
.001 33 12 18 AVI
.001 33 12 22 AV2
.001 33 12 35 AV4
.001 33 12 27 AV5
.001 33 12 11 AV6
.00!
34 12 11 AV6
.001 31 13 13 AV3
.001 31 13 11 AV5
.001 34 13 34 AV3
.001 34 13 16 AV4
.001 34 13 15 AV5
.001 34 13 16 AV6
.00!
32 14 29 AV4
.001 32 14 12 AV5
.001 32 14 13 AV6
.001
-+-
- - -+-
+
I ROW COL PER LOCN INCH11
+
1 ST Max
SG -
D Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+---------------------------
I ROW COL PER LOCN INCH11
-+--
- -+--
-+---
-+-----
33 14 15 AV2
.001 33 14 17 AV3
.001 33 14 23 AV4
.001 34 14 14 AV2
.001 34 14 19 AV6
.001 35 14 16 AV1
.001 35 14 16 AV4
.001 35 14 21 AV5
.001 35 14 16 AV6
.001 36 14 16 AV6
.001 33 15 18 AV4
.001 35 15 14 AV2
.001 35 15 15 AV4
.001 36 15 21 AV5
.001 33 16 16 AV3
.001 33 16 18 AV4
.001 36 16 14 AV3
.001 36 16 25 AV4
.001 36 16 13 AV5
.001 36 16 13 AV6
.001 37 16 20 AV3
.001 37 16 23 AV4
.001 37 16 18 AV5
.001 37 16 26 AV6
.001 38 16 22 AV3
.001 38 16 33 AV4
.001 38 16 21 AV6
.001 35 17 24 AV2
.001 35 17 26 AV3
.001
+
I ROW COL PER LOCN INCH11 2
ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
-+--
- -+--
- -+---
-+-----+
1 37 17 15 AV3
.001 37 17 29 AV4
.001 37 17 18 AV5
.001 37 17 16 AV6
.001 38 17 15 AV1
.001 38 17 15 AV2
.001 38 17 16 AV4
.001 38 17 21 AV6
.001 34 18 18 AV4
.001 35 18 13 AV3
.001 35 18 17 AV5
.001 37 18 16 AVl
.001 37 18 18 AV3
.001 37 18 19 AV4
.001 37 18 13 AV5
.001 38 18 17 AV4
.001 38 18 14 AV5
.001 38 18 17 AV6
.001 39 18 18 AV2
.001 39 18 22 AV3
.001 41 18 17 AVi
.001 41 18 18 AV3
.001 41 18 20 AV4
.001 41 18 19 AV5
.001 26 19 25 4H
-. 591 33 19 17 AV3
.001 37 19 12 AVi
.001 37 19 25 AV3
.001 37 19 13 AV4
.001 38 19 12 AVi
.001 38 19 28 AV3
.001
+-----------------------------+
I ROW COL PER LOCN INCH11
+
3 ST Max
SG -
D Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05 I ROW COL PER LOCN INCH11
-+-- - -+-
1 38 19 14 AV5
.001 38 19 15 AV6
.001 39 19 30 AV2
.001 39 19 22 AV3
.001 39 19 18 AV5
.001 39 19 17 AV6
.001 40 19 16 AV2
.001 40 19 18 AV4
.001 40 19 15 AV5
.001 40 19 12 AV6
.001 32 20 17 AV3
.001 37 20 16 AV2
..001 37 20 13 AV3
.001 37 20 20 AV4
.001 39 20 26 AV2
.001 39 20 35 AV3
.001 39 20 16 AV4
.001 40 20 22 AV4
.001 40 20 20 AV6
.001 31 21 14 TSH
.061 37 21 17 AV2
.001 37 21 15 AV4
.001 37 21 12 AV5
.001 38 21 19 AV2
.001 38 21 15 AV3
.001 38 21 18 AV4
.001 39 21 17 AV3
.001 I39 21 16 AV5
.001 40 21 16 AV4
.001 40 21 17 AV5
.001 40 21 16 AV6
.001
+
I ROW COL PER LOCN INCH11 4
ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05 I ROW COL PER LOCN INCHI1
+
41 21 15 AVI
.001 41 21 10 AV2
.001 41 21 19 AV5
.001 41 21 18 AV6
.001 38 22 15 AV2
.001 38 22 23 AV3
.001 38 22 18 AV4
.001 38 22 22 AV6
.001 40 22 19 AV3
.001 41 22 25 AV2
.001 41 22 30 AV3
.001 41 22 29 AV5
.001 41 22 24 AV6
.001 42 22 15 AV2
.001 42 22 14 AV4
.001 42 22 21 AV5
.001 42 22 20 AV6
.001 30 23 13 AV2
.001 35 23 18 AV3
.001 38 23 15 AV5
.001 38 23 16 AV6
.001 40 23 15 AV4
.001 40 23 22 AV5
.001 45 23 13 AV3
.001 45 23 13 AV6
.001 39 24 20 AV2
.001 39 24 24 AV4
.001 42 24 22 AV2
.001 42 24 24 AV4
.001 42 24 16 AV6
.001
- - -+-
I ROW COL PER LOCN INCH11 5
ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
39 25 23 AV3
.001 39 25 18 AV5
.001 41 25 21 AV3
.001 41 25 18 AV5
.001 42 25 15 AV5
.001 43 25 22 AV2
.001 43 25 37 AV3
.001 43 25 31 AV4
.001 43 25 16 AV5
.001 43 25 22 AV6
.001 44 25 30 AV3
.001 44 25 26 AV4
.001 44 25 16 AV5
.001 44 25 15 AV6
.001 47 25 27 AV4
.001 47 25 18 AV6
.001 32 26 14 AV6
.001 37 26 19 AV2
.001 37 26 13 AV5
.001 37 26 13 AV6
.001 42 26 15 AV2
.001 47 26 20 AV5
.001 47 26 24 AV6
.001 48 26 17 AV3
.001 48 26 28 AV4
.001 48 26 17 AV5
.001 48 26 27 AV6
.001 41 27 23 AV2
.001 41 27 17 AV4
.001 41 27 16 AV5
.001
+
I ROW COL PER LOCN INCH11
+
6 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
43 27 16 AV2
.001 43 27 31 AV3
.001 43 27 13 AV4
.001 43 27 21 AV5
.001 43 27 20 AV6
.001 44 27 17 AV4
.001 44 27 17 AV5
.001 45 27 13 AV2
.001 45 27 11 AV3
.001 45 27 12 AV4
.001 45 27 14 AV5
.001 47 27 20 AV5
.001 47 27 17 AV6
.001 37 28 18 AV6
.001 42 28 23 AV2
.001 42 28 18 AV3
.001 42 28 14 AV4
.001 42 28 13 AV5
.00!
42 28 17 AV6
.001 45 28 22 AV1
.001 45 28 24 AV2
.001 45 28 22 AV3
.001 45 28 16 AV4
.001 45 28 30 AV5
.001 45 28 24 AV6
.001 46 28 22 AV5
.001 46 28 19 AV6
.001 47 28 22 AV2
.001 47 28 17 AV3
.001 47 28 28 AV5
.001 47 28 19 AV6
.001 48 28 24 AV5
.001
++
I ROW COL PER LOCN INCH11
++
7 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+-
+-
+
1 48 28 19 AV6
.001 1
29 5
FBC
-. 281 44 29 23 AV3
.001 44 29 18 AV4
.001 44 29 23 AV6
.001 46 29 19 AV4
.001 46 29 19 AV5
.00!
48 29 17 AV6
.00!
50 29 15 AV4
.001 50 29 18 AV5
.001 50 29 15 AV6
.001 1
30 13 FBC
.291 42 30 21 AV2
.001 42 30 24 AV3
.00!
42 30 20 AV5
.001 43 30 13 AV2
.001 43 30 19 AV5
.001 46 30 23 AV3
.001 50 30 14 AV4
.001 50 30 30 AV6
.001 1
31 10 FBC
.291 1
31 2
FBH
-. 421 1
31 6
FBH
.241 47 31 17 AV2
.001 47 31 15 AV3
.001 47 31 18 AV4
.001 47 31 36 AV5
.001 49 31 20 AV3
.001 49 31 20 AV3
.001 I ROW COL PER LOCN INCH11
+
8 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
1 49 31 14 AV4
.001 49 31 20 AV5
.001 49 31 25 AV6
.001 50 31 25 AV4
.001 50 31 29 AV5
.001 50 31 15 AV6
.001 1
32 5
FBC
-. 291 1
32 3
FBH
-. 341 1
32 4
FBH
.341 32 32 19 AV3
.001 41 32 19 AV3
.001 41 32 20 AV4
.001 47 32 24 AV4
.001 47 32 32 AV5
.001 47 32 19 AV6
.001 49 32 13 AVI
.001 49 32 14 AV2
.001 49 32 29 AV3
.001 49 32 24 AV4
.001 49 32 19 AV5
.001 49 32 22 AV6
.001 50 32 24 AV1
.001 50 32 26 AV2
.001 50 32 24 AV3
.001 50 32 32 AV4
.001 50 32 26 AV5
.001 50 32 13 AV6
.001 1
33 6
FBC
-. 431 1
33 10 FBC
.291 1
33 5
FBH
-.421 1
33 6
FBH
.371 37 33 18 AV2
.001 37 33 22 AV3
.001
+
I ROW COL PER LOCN INCH11 9
ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05 I ROW COL PER LOCN INCH11 47 33 14 AV2
.001 47 33 13 AV3
.001 47 33 21 AV4
.001 47 33 17 AV5
.001 47 33 18 AV6
.001 48 33 19 AV2
.001 48 33 15 AV3
.001 48 33 16 AV4
.001 48 33 15 AV5
.001 52 33 28 AV6
.001 33 34 16 AV1
.001 33 34 16 AV2
.001 33 34 16 AV3
.001 33 34 15 AV4
.001 33 34 19 AV5
.001 33 34 15 AV6
.001 35 34 19 AV3
.001 48 34 17 AVI
.001 48 34 41 AV2
.001 48 34 40 AV3
.001 48 34 26 AV4
.001 48 34 34 AV5
.001 48 34 18 AV6
.001 52 34 17 AV6
.001 35 35 14 AV2
.001 35 35 11 AV4
.001 37 35 25 AV4
.001 37 35 25 AV5
.001 37 35 16 AV6
.001 39 35 14 AV2
.001 45 35 20 AV2
.001 I ROW COL PER LOCN INCH11 10 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05 I ROW COL PER LOCN INCH11
+ ---- ---- ---- ---- ---- ----+
1 45 35 18 AV3
.001 45 35 18 AV4
.001 45 35 19 AV5
.001 53 35 14 AV2
.001 53 35 40 AV3
.001 53 35 24 AV5
.001 54 35 19 AV5
.001 41 36 17 AV2
.001 41 36 14 AV3
.001 43 36 22 AV2
.001 43 36 20 AV4
.001 43 36 17 AV5
.001 47 36 15 AV2
.001 47 36 19 AV4
.001 47 36 17 AV5
.001 47 36 17 AV6
.001 39 37 22 AV2
.001 39 37 22 AV3
.001 39 37 20 AV4
.001 39 37 18 AV5
.001 41 37 25 AV3
.001 41 37 20 AV4
.001 42 37 15 AV4
.001 43 37 14 AV4
.001 43 37 14 AV5
.001 49 37 15 AV2
.001 49 37 23 AV3
.001 49 37 22 AV4
.001 49 37 16 AV5
.001 49 37 20 AV6
.001 50 37 17 AV6
.001 I ROW COL PER LOCN INCH11
-+-
11 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
-+- --------
I ROW COL PER LOCN INCH11
+
1 51 37 18 AV2
.001 54 37 15 AVI
.001 54 37 14 AV5
.001 40 38 16 AV5
.001 42 38 20 AV2
.001 42 38 21 AV4
.001 42 38 19 AV5
.001 43 38 21 AV2
.001 43 38 12 AV3
.001 43 38 36 AV4
.001 43 38 33 AV5
.001 43 38 13 AV6
.001 46 38 22 AV3
.001 46 38 20 AV4
.001 46 38 23 AV5
.001 49 38 17 AV3
.001 49 38 28 AV4
.001 49 38 18 AV5
.001 51 38 19 AV4
.001 51 38 20 AV5
.001 44 39 15 AV2
.001 44 39 14 AV4
.001 45 39 15 AV3
.001 46 39 16 AV2
.001 46 39 20 AV4
.001 46 39 22 AV5
.001 49 39 14 AV2
.001 49 39 18 AV3
.001 52 39 23 AV3
.001 I ROW COL PER LOCN INCH11 12 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCHI1
+
1 52 39 36 AV4
.001 1 52 39 25 AV5
.001 38 40 28 AV2
.001 38 40 16 AV4
.001 38 40 18 AV5
.001 41 40 14 AV3
.001 41 40 18 AV4
.001 41 40 15 AV6
.001 39 41 15 AVi
.00I 39 41 19 AV2
.001 39 41 27 AV3
.001 39 41 30 AV4
.001 39 41 20 AV5
.001 42 41 19 AV2
.001 42 41 29 AV3
.001 42 41 21 AV4
.001 42 41 26 AV5
.001 42 41 21 AV6
.001 51 41 22 AV1
.001 51 41 25 AV2
.001 51 41 39 AV3
.001 25 42 17 AV2
.001 25 42 18 AV5
.001 33 42 16 AV4
.001 37 42 19 AV3
.001 37 42 29 AV4
.001 41 42 17 AV4
.001 43 42 14 AV5
.001 45 42 15 AV2
.001 47 42 24 AV4
.001
+
I ROW COL PER LOCN INCH11
-+--
- -+-
-+-
+------+
13 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
47 42 28 AV5
.001 47 42 16 AV6
.001 41 43 37 AV2
.001 41 43 35 AV3
.001 41 43 16 AV4
.001 41 43 35 AV5
.001 43 43 25 AV2
.001 43 43 13 AV3
.001 45 43 22 AV3
.001 45 43 35 AV4
.001 45 43 31 AV5
.001 45 43 25 AV6
.001 42 44 19 AV4
.001 42 44 16 AV5
.001 43 44 24 AV2
.001 43 44 35 AV3
.001 43 44 19 AV4
.001 43 44 20 AV5
.001 43 44 22 AV6
.001 49 44 15 AV5
.001 49 44 20 AV6
.001 33 45 14 AV4
.001 44 45 15 AV5
.001 46 45 17 AV3
.001 46 45 18 AV4
.001 46 45 14 AV6
.001 51 45 22 AV4
.001 44 46 15 AV1
.001 44 46 14 AV2
.001 44 46 19 AV5
.001
+
I ROW COL PER LOCN INCH11 14 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+.
+
I ROW COL PER LOCN INCH11
+
1 45 46 15 AV2
.001 45 46 14 AV3
.001 45 46 16 AV4
.001 45 46 16 AV5
.001 45 46 19 AV6
.001 41 47 28 AV2
.001 41 47 25 AV4
.001 41 47 22 AV5
.00O 41 47 26 AV6
.001 43 47 17 AV6
.001 50 47 21 AV2
.001 50 47 15 AV3
.001 50 47 16 AV4
.001 50 47 20 AV5
.001 50 47 16 AV6
.001 41 48 14 AV3
.001 44 48 20 AV5
.001 44 49 19 AV2
.001 44 49 17 AV4
.001 44 49 27 AV5
.001 44 49 17 AV6
.001 45 49 14 AV4
.001 45 49 12 AV5
.001 46 49 15 AV2
.001 49 49 20 AV2
.001 56 49 15 AV2
.001 56 49 14 AV4
.001 56 49 14 AV5
.001 58 49 12 AV1
.001 40 50 28 AV3
.001
-+--
-+-- - -+--
-+-----+
I ROW COL PER LOCN INCH11
+
15 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
1 40 50 29 AV4
.001 1 40 50 28 AV5
.001 48 50 17 AV1
.001 48 50 32 AV3
.001 48 50 32 AV4
.001 48 50 33 AV5
.001 48 50 12 AV6
.001 51 50 14 AV1
.001 52 50 14 AV2
.001 52 50 20 AV3
.001 52 50 16 AV4
.001 52 50 16 AV5
.001 50 51 19 AVI
.001 50 51 32 AV2
.001 50 51 13 AV3
.001 50 51 25 AV4
.001 50 51 23 AV5
.001 50 51 11 AV6
.001 41 52 16 AV2
.001 41 52 14 AV3
.001 41 52 18 AV4
.001 44 52 18 AV2
.001 52 52 25 AV2
.001 52 52 37 AV3
.001 59 52 12 AVI
.001 59 52 10 AV5
.001 25 53 21 AV2
.001 25 53 22 AV5
.001 30 53 13 AV2
.001 30 53 15 AV5
.001 36 53 20 AV2
.001
+
I ROW COL PER LOCN INCH11
+
16 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCHI1
+
1 36 53 18 AV5
.001 37 53 18 AV4
.001 37 53 22 AV5
.001 39 53 16 AV3
.001 33 54 22 AV2
.001 35 54 14 AV2
.001 35 54 19 AV3
.001 35 54 24 AV4
.001 35 54 26 AV5
.001 35 54 17 AV6
.001 38 54 26 AV3
.001 38 54 33 AV4
.001 38 54 34 AV5
.001 50 54 12 AV2
.001 50 54 16 AV4
.001 50 54 19 AV6
.001 51 54 17 AV2
.001 51 54 17 AV3
.001 51 54 24 AV4
.001 51 54 14 AV5
.001 25 55 15 AVi
.001 25 55 15 AV2
.001 39 55 15 AVi
.001 39 55 13 AV2
.001 39 55 18 AV4
.001 39 55 14 AV5
.001 39 55 18 AV6
.001 41 55 22 AV2
.001 41 55 31 AV3
.001 41 55 33 AV4
.001 41 55 25 AV5
.001 41 55 19 AV6
.001
+ ---.
---+
I ROW COL PER LOCN INCH11
+
17 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
-+--
-+-
+- ---
+-----+
45 55 18 AV2
.001 45 55 17 AV3
.001 45 55 27 AV4
.001 45 55 16 AV5
.001 45 55 17 AV6
.001 48 55 25 AV3
.001 52 55 19 AV2
.001 34 56 39 AV2
.001 34 56 25 AV3
.001 34 56 16 AV4
.001 34 56 35 AV5
.001 34 56 15 AV6
.001 44 56 23 AV6
.001 45 56 18 AVi
.001 45 56 38 AV2
.001 45 56 28 AV3
.001 45 56 33 AV4
.001 45 56 32 AV5
.001 45 56 20 AV6
.001 50 56 14 AVI
.001 50 56 18 AV2
.001 50 56 29 AV3
.001 50 56 36 AV4
.001 50 56 24 AV5
.001 50 57 20 AV2
.001 50 57 17 AV3
.001 51 57 17 AV4
.001 51 57 17 AV6
.001 35 58 11 AV2
.001 1 36 58 15 AV4
.001
+
I ROW COL PER LOCN INCH11
-- -+--
-+--
- -+---
+------+
18 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05 I ROW COL PER LOCN INCHI1
+
1 41 58 12 AV2
.001 41 58 21 AV4
.001 41 58 23 AV5
.001 50 58 22 AV3
.001 50 58 20 AV4
.001 50 58 14 AV5
.001 50 58 14 AV6
.001 50 59 32 AV2
.001 50 59 30 AV4
.001 50 59 18 AV5
.001 50 59 18 AV6
.001 35 60 16 AV3
.001 35 60 29 AV5
.001 40 60 16 AV4
.001 40 60 12 AV5
.001 33 61 19 AV2
.001 33 61 18 AV3
.001 35 61 14 AV2
.001 35 61 15 AV2
.001 35 61 19 AV3
.001 44 61 14 AVI
.001 44 61 16 AV2
-001 44 61 36 AV3
.001 44 61 28 AV4
.001 44 61 20 AV6
.001 44 61 23 5H
-. 571 55 62 34 AV1
.001 55 62 33 AV2
.001 55 62 17 AV3
.001 40 63 19 AV2
.001 40 63 15 AV3
.001 1 41 63 12 AV5
.001
+
I ROW COL PER LOCN INCH11
-+--
- -+-
-+-
+
19 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCHI1
-+--
- -+--
-+---
-+-------
33 64 17 AV2
.001 33 64 17 AV3
.001 33 64 24 AV4
.001 33 64 14 AV5
.001 38 64 13 AV2
.001 38 64 17 AV3
.001 41 64 22 AV3
.001 41 64 12 AV4
.00 41 64 18 AV5
.001 44 64 13 AV2
.001 47 64 14 AV2
.001 15 65 30 5H
.041 40 65 11 AV2
.001 45 65 15 AVi
.001 45 65 14 AV2
.001 31 66 19 AV2
.001 31 66 17 AV6
.001 33 66 17 AV2
.001 33 66 18 AV3
.001 41 66 15 AV1
.001 41 66 20 AV2
.001 41 66 28 AV3
.001 41 66 36 AV4
.001 41 66 22 AV5
.001 41 66 29 AV6
.001 44 66 16 AV2
.001 44 66 15 AV3
.001 44 67 17 AV2
.001 44 67 17 AV3
.001
+
I ROW COL PER LOCN INCH11
+
20 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+----
+
I ROW COL PER LOCN INCH11
+
1 44 67 19 AV4
.001 34 68 17 AV2
.001 40 68 16 AV2
.001 40 68 13 AV3
.001 40 68 13 AV4
.001 45 68 19 AV2
.001 46 68 27 AV2
.001 46 68 17 AV3
.001 50 68 19 AV4
.001 31 69 13 AV1
.001 31 69 13 AV2
.001 31 69 16 AV5
.001 34 69 16 AV2
.001 34 69 19 AV3
.001 36 69 13 AV3
.001 52 69 18 AV1
.001 30 70 12 AV1
.001 30 70 16 AV2
.001 33 70 14 AV2
.001 39 70 10 AV2
.001 44 70 18 AVI
.001 44 70 23 AV2
.001 44 70 14 AV3
.001 44 70 27 AV5
.001 44 70 27 AV6
.001 45 70 17 AV2
.001 46 70 28 AV2
.00I 4---------+
I ROW COL PER LOCN INCH11
+
21 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
- - -+-
+- -+- -------
+
1 46 70 22 AV3
.001 50 70 27 AV2
.001 50 70 23 AV3
.001 55 70 16 AV3
.001 55 70 21 AV5
.001 57 70 19 AV5
.001 58 70 15 AV2
.001 36 71 36 AV1
.001 36 71 28 AV2
.001 36 71 29 AV3
.001 36 71 27 AV4
.001 36 71 31 AV5
.001 36 71 18 AV6
.001 24 72 18 AV2
.001 32 72 33 AV1
.001 32 72 19 AV2
.001 32 72 20 AV5
.001 34 72 12 AV2
.001 36 73 18 AV2
.001 36 73 15 AV4
.001 36 73 20 AV5
.001 58 73 14 AV2
.001 39 74 16 AV3
.001 39 74 15 AV4
.001 45 74 16 AV1
.001 45 74 15 AV2
.001 48 74 29 AV2
.001 48 74 17 AV3
.001
+ - --.
- --+
I ROW COL PER LOCN INCH11
+
22 ST Max
SG -
D Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+.
+
I ROW COL PER LOCN INCH11
+.
+
39 75 17 AV2
.001 39 75 20 AV3
.001 39 75 20 AV4
.001 39 75 19 AV5
.001 44 75 19 AVi
.001 44 75 22 AV2
.001 44 75 19 AV3
.001 44 75 22 AV4
.001 44 75 13 AV5
.001 36 76 17 AV1
.001 36 76 16 AV2
.001 52 76 15 AVi
.001 52 76 15 AV2
.001 52 76 16 AV3
.001 57 76 27 AV4
.001 57 76 35 AV5
.001 44 77 22 AV3
.001 44 77 16 AV4
.001 39 78 25 AV3
.001 39 78 17 AV4
.001 39 78 20 AV5
.001 41 78 16 AV2
.001 46 78 22 AV2
.001 50 78 16 AVi
.001 50 78 22 AV2
.001 50 78 34 AV3
.001 50 78 20 AV4
.001 28 79 13 AV2
.001 28 79 13 AV5
.001 33 79 15 AV5
.001
+
I ROW COL PER LOCN INCH11
+
23 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
1 39 79 22 AV2
.001 42 79 19 AV3
.001 36 80 18 AV3
.001 36 80 20 AV4
.001 37 80 15 AV2
.001 39 80 23 AV2
.001 39 80 18 AV4
.001 50 80 17 AV2
.001 50 80 16 AV3
.001 50 80 17 AV4
.001 56 80 15 AV4
.001 37 81 14 AV2
.001 37 81 21 AV3
.001 37 81 15 AV4
.001 43 81 11 AVI
.001 43 81 18 AV2
.001 43 81 28 AV3
.001 43 81 15 AV4
.001 43 81 21 AV5
.001 47 81 27 AV3
.001 49 81 26 AV2
.001 51 81 39 AV2
.001 51 81 18 AV3
.001 51 81 25 AV4
.001 51 81 23 AV5
.. 001 51 81 18 AV6
.001 24 82 15 AV2
.001 24 82 12 AV6
.001 43 82 19 AV2
.001
+
I ROW COL PER LOCN INCH11
+
24 ST Max
SG -
D Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
-+--
-+-
+- ---
+-----+
1 43 82 24 AV4
.001 45 82 17 AV2
.001 45 82 38 AV3
.001 45 82 17 AV5
.001 45 82 13 AV6
.001 49 82 21 AV2
.001 39 83 27 AV3
.001 39 83 22 AV4
.001 39 83 11 AV5
.001 39 83 15 AV6
.001 40 83 20 AV3
.001 44 83 18 AV2
.001 45 83 15 AV2
.001 48 83 14 AV2
.001 48 83 21 AV4
.001 20 84 21 AV6
.001 32 84 12 AV3
.001 32 84 14 AV6
.001 41 84 19 AVi
.001 41 84 29 AV3
.001 41 84 24 AV4
.001 41 84 24 AV5
.001 46 84 15 AVi
.001 46 84 14 AV2
.001 46 84 33 AV3
.001 46 84, 22 AV4
.001 24 85 19 AV6
.001 35 85 12 AV3
.001 35 85 18 AV4
.001
+
I ROW COL PER LOCN INCH11 25 ST Max
SG -
D Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+.
+
46 85 17 AV3
.001 46 85 21 AV4
.001 49 85 28 AV2
.001 49 85 19 AV3
.001 49 85 21 AV4
.001 49 85 22 AV5
.001 50 85 27 AV4
.001 50 85 24 AV5
.001 50 85 18 AV6
.001 26 86 15 AV5
.001 40 86 21 AV3
.001 41 86 19 AV4
.001 28 87 15 AV2
.001 30 87 14 AV2
.001 36 87 16 AVi
.001 38 87 14 AV3
.001 40 87 18 AV1
.001 40 87 19 AV2
.001 40 87 20 AV3
.001 40 87 33 AV4
.001 40 87 14 AV5
.001 47 87 16 AVl
.001 50 87 21 AV4
.001 50 87 19 AV5
.001 20 88 20 AV1
.001 35 88 13 AV3
.001
- -+-
- -+------
I ROW COL PER LOCN INCH11 26 ST Max
SG -
D Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05 I ROW COL PER LOCN INCH11
-+-
- - -+-
-+-----+
1 38 88 16 AV2
.001 38 88 16 AV3
.001 43 88 14 AVI
.001 45 88 12 AV2
.001 45 88 16 AV3
.001 45 88 20 AV4
.001 45 88 31 AV5
.001 49 88 21 AV3
.001 49 88 22 AV4
.001 49 88 16 AV5
.001 50 88 20 AV2
.001 50 88 16 AV3
.001 50 88 20 AV4
.001 50 88 25 AV5
.001 53 88 11 AV2
.001 36 89 18 AV3
.001 38 89 24 AV3
.001 38 89 26 AV4
.001 38 89 22 AV5
.001 39 89 20 AV2
.001 47 89 16 AV1
.001 50 89 22 AV3
.001 50 89 15 AV4
.001 50 89 16 AV5
.001 1
90 4
FBC
-. 341 1
90 7
FBC
.291 36 90 20 AV3
.001 36 90 14 AV4
.001 36 90 21 AV6
.001
+
I ROW COL PER LOCN INCH11
-+--
- -+-
-+-
+------+
27 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
1 38 90 15 AV3
.001 39 90 20 AVi
.001 39 90 20 AV2
.001 39 90 14 AV5
.001 45 90 20 AV3
.001 48 90 16 AV3
.001 48 90 17 AV5
.001 53 90 24 AV4
.001 53 90 21 AV5
.001 53 90 25 AV6
.001 1
91 7
FBC
-.361 1
91 7
FBH
.051 32 91 17 AVi
.001 32 91 18 AV5
.001 36 91 19 AV2
.001 36 91 24 AV4
.001 37 91 14 AV3
.001 1
92 8
FBC
-. 361 1
92 7
FBH
.001 1
92 4
FBH
.311 19 92 18 AV6
.001 40 92 19 AVi
.001 40 92 24 AV3
.001 40 92 18 AV5
.001 43 92 11 AV2
.001 43 92 31 AV3
.001 43 92 16 AV4
.001 43 92 16 AV5
.001 45 92 16 AV3
.001 I ROW COL PER LOCN INCH11
+
28 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
1 45 92 23 AV4
.001 1 45 92 25 AV5
.001 49 92 28 AV2
.001 49 92 16 AV3
.001 49 92 28 AV4
.001 49 92 19 AV5
.001 1
93 8
FBC
.001 45 93 14 AV3
.001 45 93 22 AV4
.001 45 93 22 AV5
.001 45 93 17 AV6
.001 1
94 2
FBC
.001 39 94 14 AV3
.001 41 94 32 AV2
.001 41 94 32 AV3
.001 41 94 28 AV4
.001 41 94 24 AV5
.001 41 94 13 AV6
.001 43 94 31 AV2
.001 43 94 17 AV3
.001 43 94 20 AV4
.001 43 94 24 AV5
.001 44 94 17 AV3
.001 44 94 17 AV4
.001 35 95 10 AVI
.001 35 95 14 AV5
.001 38 95 23 AV2
.001 38 95 14 AV3
.001 40 95 16 AV5
.001 40 95 23 AV6
.001
+
I ROW COL PER LOCN INCH11
+
29 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCHI1 1 41 95 20 AV2
.001 41 95 17 AV4...
.001 41 95 23 AV5
.001 44 95 19 AV2
.001 44 95 29 AV3
.001 45 95 14 AV1
.001 45 95 16 AV2
.001 45 95 18 AV3
.001 45 95 27 AV4
.001 45 95 34 AV5
.001 45 95 21 AV6
.001 48 95 17 AV4
.001 41 96 24 AV2
.001 41 96 36 AV3
.001 41 96 17 AV5
.001 44 96 21 AV2
.001 44 96 32 AV3
.001 44 96 16 AV4
.001 44 96 18 AV6
.001 45 96 23 AV2
.001 45 96 31 AV5
.001 27 97 15 TSH
-.811 38 97 16 AV4
.001 38 97 18 AV5
.001 40 97 17 AV3
.001 40 97 19 AV4
.001 41 97 24 AV3
.001 41 97 34 AV4
.001 46 97 26 AV3
.001 40 98 24 AV2
.001 I ROW COL PER LOCN INCH11 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
1 40 98 25 AV3
.001 1 40 98 19 AV4
.001 40 98 17 AV6
.001 38 99 21 AV2
.001 38 99 19 AV3
.001 41 99 18 AV2
.001 41 99 16 AV3
.001 41 99 14 AV4
.001 41 99 16 AV6
.001 43 99 14 AV5
.001 34 100 14 AV3
.001 38 100 21 AV2
.001 38 100 19 AV3
.001 38 100 16 AV4
.001 38 100 21 AV5
.001 40 100 22 AV2
.001 40 100 20 AV6
.001 41 100 29 AV2
.001 41 100 25 AV3
.001 41 100 25 AV4
.001 41 100 19 AV5
.001 42 100 21 AV3
.001 42 100 32 AV4
.001 36 101 16 AV2
.001 38 101 34 AV3
.001 38 101 25 AV4
.001 38 101 17 AV5
.001 38 102 17 AV3
.001 40 102 22 AV2
.001 40 102 38 AV3
.001
-+--
-+-- - -+--
-+-----+
I ROW COL PER LOCN INCH11 31 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05 I ROW COL PER LOCN INCH11 1 40 102 37 AV4
.001 26 103 13 AV5
.001 34 103 16 AV3
.001 34 103 13 AV4
.001 34 103 19 AV6
.001 36 103 13 AV3
.001 36 103 17 AV4
.001 38 103 12 AV2
.001 38 103 20 AV3
.001 38 103 36 AV4
.001 38 103 29 AV5
.001 40 103 20 AV2
.001 40 103 31 AV3
.001 40 103 28 AV4
.001
- 40.
103 14 AV5
.001 40 103 17 AV6
.001 43 103 13 AV4
.001 32 104 23 AV5
.001 34 104 17 AV3
.001 34 104 17 AV4
.001 35 104 17 AV3
.001 35 104 15 AV4
.001 35 104 17 AV5
.001 38 104 19 AV3
.001 40 104 40 AV2
.001 40 104 29 AV3
.001 40 104 19 AV4
.001 40 104 24 AV5
.001 40 104 20 AV6
.001 1 30 105 12 AV2
.001
+
I ROW COL PER LOCN INCH11 32 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05
+
I ROW COL PER LOCN INCH11
+
33 105 12 AV3
.001 33 105 15 AV5
.001 35 105 13 AV6
.001 38 105 36 AV3
.001 38 105 24 AV4
.001 38 105 10 AV6
.001 34 106 16 AV2
.001 34 106 15 AV4
.00!
34 106 19 AV6
.001 35 106 22 AV2
.001 35 106 20 AV3
.001 35 106 14 AV4
.001 35 106 18 AV6
.001 36 106 14 AV4
.001 36 106 16 AV5
.001 40 106 16 AV4
.001 35 107 25 AV3
.001 35 107 20 AV4
.001 35 107 16 AV5
.001 35 107 12 AV6
.001 36 107 22 AV4
.001 36 107 22 AV5
.001 35 108 18 AV3
.001 35 108 31 AV4
.001 35 108 18 AV5
.001 35 108 19 AV6
.001 37 108 15 AV6
.001 38 108 14 AV6
.001 28 109 19 AV5
.001
+
I ROW COL PER LOCN INCH11
+
33 ST Max
SG -
D Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05 I ROW COL PER LOCN INCH11
+.
+
32 109 13 AV5
.001 32 109 12 AV6
.001 33 109 17 AV3
.001 33 109 20 AV4
.001 33 109 23 AV5
.001 34 109 13 AV2
.001 34 109 11 AV4
.001 34 109 11 AV5
.001 34 109 14 AV6
.001 36 109 13 AV6
.001 29 110 15 AV5
.001 32 110 16 AV2
.001 32 110 18 AV5
.001 35 110 18 AV3
.001 35 110 33 AV4
.001 35 110 19 AV6
.001 29 111 16 AV2
.001 30 111 16 AV2
.001 30 111 17 AV6
.001 32 111 15 AV6
.001 30 112 11 AV5
.001 27 113 20 AV2
.001 30 113 22 AV5
.001 27 114 15 AV5
.001 24 115 21 AV1
.001 26 115 17 AVI
.001
+
I ROW COL PER LOCN INCH11 34 ST Max
SG D
Service Induced Indications Wolf Creek 1 XVIII SAP 20110401 04/28/2011 18:02:05 I ROW COL PER LOCN
-+H INCHill
-+
I 27 115 14 AV1
.001 I
27 115 17 AV6
.001 I
22 116 15 AV6
.001
+--
I ROW COL PER LOCN INCH11 Tubes: 418 Records: 1016 35 ST Max