Letter Sequence Draft RAI |
|---|
|
|
MONTHYEARNL-11-0464, Proposed Alternative for the Fourth Lsi Interval2011-03-22022 March 2011 Proposed Alternative for the Fourth Lsi Interval Project stage: Request ML1108105442011-03-22022 March 2011 Notice of Cancelled Forthcoming Meeting with Southern Nuclear Operating Company, Inc. (Snc), to Discuss NFPA 805 License Amendment for Joseph M. Farley Nuclear Plant, Units 1 and 2 Project stage: Meeting L-2011-058, Units 1 & 2 - Status Reports Decommissioning Funding Status Report for the Listed Units2011-03-23023 March 2011 Units 1 & 2 - Status Reports Decommissioning Funding Status Report for the Listed Units Project stage: Request NRC 2011-0021, License Amendment Request 262 Revision to Technical Specification Operating Limits to Include Measurement Uncertainty2011-03-23023 March 2011 License Amendment Request 262 Revision to Technical Specification Operating Limits to Include Measurement Uncertainty Project stage: Request ML1109403062011-04-0505 April 2011 Acceptance Review Letter License Amendment Request to Revise Technical Specification Operating Limits to Include Measurement Uncertainty Project stage: Acceptance Review ML11172A0812011-07-28028 July 2011 Request for Additional Information on Inservice Inspection Plan Project stage: RAI NL-11-1542, Response to NRC Request for Additional Information, Proposed Alternative FNP-ISI-ALT-11, Version 1.02011-08-16016 August 2011 Response to NRC Request for Additional Information, Proposed Alternative FNP-ISI-ALT-11, Version 1.0 Project stage: Response to RAI ML1127605592011-09-28028 September 2011 Draft Request for Additional Information LAR-262 Project stage: Draft RAI ML1127605122011-09-28028 September 2011 E-mail Transmitting Draft Request for Additional Information LAR-262 Project stage: Draft RAI ML11347A0052012-01-18018 January 2012 Safety Evaluation of Relief Request FNP-ISI-ALT-11, Version 1.0, for the Fourth 10-Year Inservice Inspection Interval Project stage: Approval ML1135401472012-01-30030 January 2012 Issuance of Amendment to Revise Technical Specification Operating Limits to Include Measurement Uncertainty Project stage: Approval 2011-07-28
[Table View] |
Text
REQUEST FOR ADDITIONAL INFORMATION Point Beach Nuclear Plant, Units 1 and 2 License Amendment Request (LAR-262) dated March 23, 2011 Revision to Technical Specification Operating Limits to Include Measurement Uncertainty (TAC Nos. ME5906 and ME5907)
The technical staff in the Reactor Systems Branch (SRXB) of the Office of Nuclear Reactor Regulation has developed the following request for additional information associated with its review of LAR-262.
SRXB-1 For the item relating to the Refueling Water Storage Tank (RWST) Temperature, the basis for the change states the current RWST minimum temperature of 40°F is based on the value assumed in the steam line break analysis core response.
Please identify the section in the Final Safety Evaluation Report (FSAR) that confirms this minimum temperature of 40°F.