ML11265A074
| ML11265A074 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 09/22/2011 |
| From: | Jason Paige Plant Licensing Branch II |
| To: | Tomonto B Florida Power & Light Co |
| References | |
| TAC ME6891, TAC ME6892 | |
| Download: ML11265A074 (2) | |
Text
1 NRR-PMDAPEm Resource From:
Paige, Jason Sent:
Thursday, September 22, 2011 8:28 AM To:
Tomonto, Bob Cc:
Hanek, Olga; Everett, Ronald
Subject:
ACCEPTANCE REVIEW: Turkey Point Accident Monitoring Instrumentation TS Changes LAR (ME6891 and ME6892)
SUBJECT:
ACCEPTANCE REVIEW: Turkey Point Accident Monitoring Instrumentation TS Changes LAR (ME6891 and ME6892)
By letter dated August 17, 2011, Florida Power & Light Co. submitted a license amendment for Turkey Point Units 3 and 4. The purpose of this e-mail is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staffs acceptance review of this amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.
If you have any questions, please contact me.
Jason Paige, Turkey Point Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation US Nuclear Regulatory Commission Phone: (301) 415-5888
Hearing Identifier:
NRR_PMDA Email Number:
153 Mail Envelope Properties (Jason.Paige@nrc.gov20110922082800)
Subject:
ACCEPTANCE REVIEW: Turkey Point Accident Monitoring Instrumentation TS Changes LAR (ME6891 and ME6892)
Sent Date:
9/22/2011 8:28:07 AM Received Date:
9/22/2011 8:28:00 AM From:
Paige, Jason Created By:
Jason.Paige@nrc.gov Recipients:
"Hanek, Olga" <Olga.Hanek@fpl.com>
Tracking Status: None "Everett, Ronald" <Ronald.Everett@fpl.com>
Tracking Status: None "Tomonto, Bob" <Bob.Tomonto@fpl.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 1856 9/22/2011 8:28:00 AM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: