-- #F Doyle, Daniel From:
Doyle, Daniel Sent:
Wednesday, February 09, 2011 10:51 AM To:
Dennig, Robert Cc:
Wentzel, Michael; Perkins, Leslie; Lehman, Bryce
Subject:
Basemat and containment question Categories:
Salem Hope Creek
- Robert, I am coordinating the NRC response to two public comments received on the Salem/Hope Creek draft SEIS for license renewal. The two comments are below. I checked with RASB in DLR and they provided a draft response to the first comment but recommended that I check with your branch to review the draft response and provide the response to the second comment.
Can you help me with this or point me in the right direction? Thanks for your time.
Comment SHC-W-14: SAMA - Breakdown of Population Dose by Containment Release Mode for Salem Generating Station / Table 5-4 / Page 5-6 / Line 10.
For the "Basemat Melt Through (BMT)", population dose is considered negligible. The BMT is a protection system for the basemat of reactor containment buildings in nuclear power stations. The system comprises a structure located in a cavity below the reactor vessel and submerged in water.
The structure comprises staggered layers of stainless steel beams for intercepting molten material escaping from the reactor vessel during meltdown of the reactor core. The system is designed so that the molten material is distributed in thin layers over wings of the beams and transfers its heat to the surrounding water thus affording a rapid quenching of the molten core and safeguarding the integrity of the basemat.
Would there be any chance, even within the basemat system of staggered layers of steel beams, of a flash to steam of the molten material and potential release to the atmosphere augmenting/causing a potential contribution to population dose? Have there been model studies done to confirm the report's claims of negligible contribution to population dose? The steam generated during this core melt must be relieved somewhere.
Response (draft): At Salem there are several safety systems designed to maintain the containment post-accident pressure below the design pressure. Per Salem's UFSAR Section 6.2.2, the Containment Fan Cooling System and the Containment Spray System maintain the post-accident containment pressure and temperature below design values. These systems are designed to address pressure and temperature spikes after a LOCA; however, they would operate the same way if there were spikes due to steam related to core melt.
Comment SHC-W-15: Why is there no basemat system present at Hope Creek Generating Station? Is it related to the design of the HCGS BWR?
Response: (insert response)
Dan Doyle 18
i Project Manager Division of License Renewal U.S. Nuclear Regulatory Commission daniel.doyle(anrc.qov (301) 415-3748 19