ML112430077
| ML112430077 | |
| Person / Time | |
|---|---|
| Site: | 07201030, North Anna |
| Issue date: | 08/25/2011 |
| From: | Jennivine Rankin NRC/NMSS/SFST/LID |
| To: | Hartz L Virginia Electric & Power Co (VEPCO) |
| Rankin J, NMSS/SFST/LB 492-3268 | |
| References | |
| TAC L24551 | |
| Download: ML112430077 (4) | |
Text
August 25, 2011 Mr. L. N. Hartz Vice President, Nuclear Support Services Virginia Electric and Power Company 5000 Dominion Boulevard Glen Allen, VA 23060
SUBJECT:
REQUEST FOR EXEMPTIONS FROM CERTAIN REQUIREMENTS IN 10 CFR PART 72 FOR THE NORTH ANNA POWER STATION INDEPENDENT SPENT FUEL STORAGE INSTALLATION - SUPPLEMENTAL INFORMATION NEEDED
Dear Mr. Hartz:
By letter dated July 21, 2011, Virginia Electric and Power Company (Dominion) requested exemptions from the requirements of 10 CFR 72.212(b)(3) and (b)(11). The exemptions were requested for NUHOMS HD Dry Shielded Canisters (DSC), Model Number HD-32PTH, with serial numbers DOM-32PTH-004-C, -005-C, -007-C, -010-C, -013-C, -019-C and GBC-32PTH-011-C due to non-compliance with the terms and conditions of the Transnuclear, Inc., Certificate of Compliance (CoC) 72-1030, Amendment No. 0. At the time of loading, the decay heat limit was exceeded for twelve fuel assemblies. The twelve fuel assemblies are distributed over the seven identified DSCs.
U.S. Nuclear Regulatory Commission staff performed an acceptance review of the exemption request, to determine if the request contains sufficient information to allow the staff to complete the detailed technical review. This letter is to advise you that based on our acceptance review, the request does not contain sufficient information. The information needed to continue our review is described in the enclosure to this letter as a Request for Supplemental Information. In order to schedule our technical review, this supplemental information should be provided by September 14, 2011. If the supplemental information is not received by this date, the review of this request may be delayed. The supplemental information requested and associated timeframe for the Dominion response were discussed with Mr. Thomas Szymanski of your staff on August 25, 2011.
If you have any questions regarding this matter, please contact me at 301-492-3268.
Sincerely,
/RA/
Jennie Rankin, Project Manager Licensing Branch Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards Docket Nos.: 50-338, 50-339, 72-56, 72-1030 TAC No.:
L24551
Enclosure:
Request for Supplemental Information cc w/encl:
Distribution via Listserv
ML112430077 G:\\SFST\\Rankin\\Surry and North Anna Exemptions\\NorthAnna RSI letter.docx OFC SFST SFST SFST SFST SFST NAME JRankin JBorowsky MSampson WWheatley MWaters DATE 8/22/11 8/22/11 8/22/11 8/22/11 8/25/11
Enclosure VIRGINIA ELECTRIC AND POWER COMPANY DOCKET NOS. 50-338, 50-339, 72-56, AND 72-1030 REQUEST FOR SUPPLEMENTAL INFORMATION RELATED TO THE REQUEST FOR EXEMPTIONS FROM CERTAIN REQUIREMENTS IN 10 CFR PART 72 FOR THE NORTH ANNA POWER STATION UNITS 1 AND 2 INDEPENDENT SPENT FUEL STORAGE INSTALLATION Request for Supplemental Information General Information Provide an environmental report.
The July 21, 2011, exemption request does not include an environmental report. To aid the staff in performing an environmental assessment, an environmental report should be submitted pursuant 10 CFR 51.60 which discusses the considerations of 10 CFR 51.45.
This information is needed for staff to complete an environmental assessment pursuant 10 CFR 51.30.
Thermal Evaluation Provide the ANSYS files required to run the thermal analyses presented in Transnuclear, Inc.
Calculation No. 10494-174, including the files listed in Section 6.0 of the calculation.
The staff needs the files to run the ANSYS thermal analyses, including those listed in Section 6.0, to verify the models presented in Transnuclear, Inc. Calculation No. 10494-174.
This information is needed to determine compliance with 10 CFR 72.122(h).