Department of Homeland Security Region IV 3003 Chamblec-Tucker Road Atlanta, Georgia 30341 igý'FEMA April 12, 2011 Victor M. McCree Regional Administrator - RII State and Local Government Affairs US Nuclear Regulatory Commission One Marquis Tower 245 Peachtree Center Avenue, Suite 1200 Atlanta, Georgia 30303

Dear Mr. McCree:

On February 23, 2011, the State of Florida successfully conducted a plume exposure pathway exercise of offsite radiological emergency plans and preparedness for the Turkey Point Nuclear Power Plant. The enclosed exercise report addresses the evaluation of the plans and preparedness for the State of Florida and the counties within the 10-mile Emergency Planning Zone. The participants included representatives from the State of Florida and local government officials, employees and volunteers from Miami-Dade and Monroe Counties. The Radiological Emergency Preparedness Program staff prepared the report.

We did not identify any Deficiencies or Areas Requiring Corrective Actions during this exercise.

Based on the results of the February 23, 2011, exercise and FEMA's review of Florida's Annual Letters of Certification for 2010, the offsite radiological emergency response plans and preparedness for the State of Florida and the affected local jurisdictions site-specific to the Turkey Point Nuclear Power Plant can be implemented and are adequate to provide reasonable assurance that appropriate measures can be taken offsite to protect the health and safety of the public in the event of a radiological emergency at the site. The Title 44 CFR, Part 350, approval of the offsite radiological emergency response plans and preparedness for the State of Florida site-specific to the Turkey Point Nuclear Power Plant, granted on February 15, 1984 will remain in effect.

)

' Should you have questions, please contact Conrad Burnside at 770/220-5486.

-Snerely, Major P. May, Regional Administrator Enclosure cc:

Ms. Vanessa E. Quinn, Branch Chief Federal Emergency Management Agency Headquarters Radiological Emergency Preparedness Branch - NP-TH-RP 1800 S uth Bell Street Arli gton, Virginia 20598-3025 iuRC Headquarters Document Control Desk U. S. Nuclear Regulatory Commission Washington, D. C. 20555-0001

Homeland Security Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise 4

TURKEY POINT NUCLEAR POWER PLANT AFTER ACTION REPORT (FINAL)

February 23, 2011 Radiological Emergency Preparedness (REP) Program 0

FEMA Published April 2011

Homeland Security Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise This page is intentionally blank

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR Administrative Handling Instructions

1. This After Action Report (AAR) for the 2011 Turkey Point Nuclear Power Plant (TPNPP)

Radiological Emergency Preparedness, Plume Phase Emergency Planning Zone (EPZ)

Exercise is considered a public document..

2. Points of

Contact:

Federal:

State of Florida:

Mr. Randall Hecht South Section Chief FEMA Region IV 3003 Chamblee-Tucker Atlanta, Georgia 30341-4122 770/220-3147 randall.hecht @ dhs.gov Mr. W. Tracy Poole REP Program Florida DEM 2555 Shumard Oak Boulevard Tallahassee, Florida 32399 229/413-2398 william.poole@em.myflorida.com Licensee Florida Power and Light Company Brian Carberry Emergency preparedness Coordinator Turkey Point Nuclear Plant 9760 SW 344th Street Homestead, Florida 33035 305-246-6485 Brian.Carberry@FPL.com Handling Instructions 2011 TPNPP REP Exercise I

Homeland Security Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise Table of Contents Page A dm inistrative H andling Instructions..............................................................................................

1 T ab le of C ontents.............................................................................................................................

2 E x ecutive S u m m ary.........................................................................................................................

4 Section 1: E xercise O verview....................................................................................................

6 Section 2: Exercise Design Summary........................................................................................

9 Section 3: Analysis of Capabilities..........................................................................................

14 3.1 Exercise Evaluation and Results.............................................................................

14 3.2 E valuation Sum m aries............................................................................................

14 3.2.1 S tate of F lorida................................................................................................

14 3.2.1.1 State Emergency Operations Center..........................................

14 3.2.1.2 Florida Incident Management Team..........................................

15 3.2.1.3 Dose Assessment.....................................................................

15 3.2.1.4 State of Florida BRC Field Teams.............................................

16 3.2.2 R isk Jurisdictions........................................................................................

19 3.2.2.1 Miami-Dade, Florida.................................................................

19 3.2.2.1.1 Miami-Dade Emergency Operations Center (EOC)...... 19 3.2.2.1.2 Miami-Dade Emergency PI WC Summary:.............. 19 3.2.2.1.3 Miami-Dade Traffic Control Points (TCP)............... 20 3.2.2.1.4 Miami-Dade Backup Route Alerting........................ 21 3.2.2.1.5 Waterway Warning...................................................

22 3.2.2.1.6 Miami-Dade Schools.................................................

22 3.2.2.2 Monroe County, Florida.............................

23 3.2.2.2.1 Tavernier Emergency Operations Center.................. 23 3.2.2.2.2 Ocean Reef Traffic Control Points...........................

24 Section 4 :

C onclusion......................................................................................................

.. 25 Table of Contents 2011 TPNPP REP Exercise 2

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR List of Appendices Appendix A: Exercise Timeline.................................

............................... 27 A ppendix B : T able 2..........................................

.2 8

Appendix C: Exercise Evaluator and Assignments........

,....... ;...................... 29 Appendix D: Acronyms

..................................................................... 31 A ppendix E : E xercise Locations..............................................

I............. 35 Appendix F:

Exercise Planning Team Leadership.................................................................

37 I

1 I

I I

1 I

I I

I I

I I

Table of Contents 2011 TPNPP REP Exercise 3

HoMomeland Security: Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise Executive Summary On February 23, 2011, the Department of Homeland Security (DHS), Federal Emergency Management Agency (FEMA) Region IV, Radiological Emergency Preparedness (REP)

Program staff evaluated a plume exposure pathway exercise in the Emergency Planning Zone (EPZ) around the Turkey Point Nuclear Power Plant (TPNPP). It is located on the slhbre of Biscayne Bay, approximately 25 miles south of the City of Miami, and 7 miles-north 'of the Monroe and Miami-Dade County line..

FEMA's overall objective for the exercise was to assess the level of State and local preparedness in responding to a radiological emergency at TPNPP. This report analyzes exercise results, identifies strengths to maintain and build upon, identifies potential areas for further improvement and supports development of corrective actions.

This exercise was conducted using the Homeland Security Exercise and Evaluation Program (HSEEP) methodology under current FEMA's policies and guidance. The ability of state and local response agencies was tested with regard to implementation of Radiological Emergency Response Plans (RERP). The evaluation team conducted this exercise using Homeland Security Exercise and Evaluation Program (HSEEP) methodology. The previous Federal-evaluated exercise for this site was conducted on February 18, 2009.

The specific objectives State and locals agencies demonstrated were:

" Objective 1: Demonstrate the ability to provide emergency operations center management including direction and control through the State and counties Emergency Operations Centers (EOC).

  • Objective 2: Demonstrate the ability to provide protective action decision-making for State and county emergency workers and the general public through exercise play and discussions of plans and procedures.
  • Objective 3: Demonstrate the ability to physically implement protective actions for State and county emergency workers and the general public through exercise demonstration and discussion of plans and procedures.

" Objective 4: Demonstrate the ability to activate the Prompt Alert and Notification utilizing the Emergency Alert System (EAS) through exercise play.

" Objective 5: Demonstrate the effectiveness of plans, policies and procedures in the Emergency News Center (ENC) for joint (public and private sector) emergency information communications.

Their objectives reflect the REP Program Exercise Evaluation Criteria as negotiated in the Extent of Play Agreements (EOPA).

The evaluation of Out-of-Sequence (OOS) activities conducted January 18-21, 2011 is included in this report.

Executive Summary 2011 TPNPP REP Exercise 4

Homeland Security Exercise and Evaluation Program (HSEEP)

.2011 Turkey Point Nuclear Power Plant REP Exercise AAR State and local organizations successfully demonstrated knowledge of theivremergency response plans and procedures and their ability to implement them. No Deficiencies or Areas Requiring Corrective Action (ARCA) were identified.

FEMA acknowledges the exceptional efforts of the many individuals who planned, prepared for and participated in this exercise. The enthusiasm, cooperation, and teamwork displayed by all participants highlighted the obvious training and preparation invested in this successful demonstration.

FEMA will provide identified strengths and areas for improvement to the State of Florida under separate cover. Those documents will be designated For Official Use Only (FOUO) in compliance with the HSEEP standards.

I I

I I

I I

I I

I I

I I

I I

I I

I 1

I Executive Summary 2011 TPNPP REP Exercise 5

Homeland Security., Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey point Nuclear Power Plant REP Exercise Section 1: Exercise Overview 1.1 Exercise Details Exercise Name 2011 Turkey Point NPP REP Evaluated Exercise Type of Exercise Full-Scale Exercise Exercise Out of Sequence/Off Scenario Dates January 18-21, 2011 Exercise' Date February 23,2011 Locations See Appendix E for a complete listing of locations of supported exercise activities.

Section 1: Exercise Overview 2011 TPNPP REP Exercise 6

Homeland Security Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey point Nuclear Power Plant REP Exercise Sponsors Florida Power and Light 9250 West Flagler Street Miami, Florida 33174 Program FEMA REP Program Mission

Response

Capabilities

" Emergency Operations Center Management

" Emergency Public Information and Warning

" Citizen Evacuation and Shelter in Place

" Emergency Public Safety and SecurityResponse

" Hazardous Materials Response and Decontamination Scenario Type REP, Full Plume Phase EPZ 1.2 Exercise Planning Team Leadership See Appendix F for a listing of the members of the exercise planning team leadership.

1.3 Participating Organizations The following agencies, organizations and units of government participated in the February 23, 2011 TPNPP REP Exercise.

State of Florida External Affairs Florida Department of Health Bureau of Radiation Control

" Agency for Health Care Administration (verify this)

Florida Division of Emergency Management Florida Highway Patrol Florida Department of Education Agriculture Extension Florida Department of Transportation Florida Department of Children and Families Florida National Guard Risk Jurisdiction - Miami-Dade, FL Miami-Dade Animal Services Miami-Dade Environmental Resources Management Miami-Dade Fire and Rescue Section 1: Exercise Overview 2011 TPNPP REP Exercise 7

Homeland Security Exercise and Evaluation Program (HSEEP)

I AAR 2011 Turkey point Nuclear Power Plant REP Exercise Miami-Dade Police Department 1

  • Homestead Divisional
  • Schools Division Miami-Dade Corrections Miami-Dade Department of Emergency Management.

Miami-Dade Health Environment 3

  • Health/Medical

'Miami-Dade Public Schools

  • Operations
  • Transportation Miami-Dade Transit Miami-Dade Water and Sewer Risk Jurisdiction..- MonroeCounty, FE.

Key Largo Ambulance Monroe Administration I

Monroe Emergency Management Agency Monroe Health Department Monroe Public Works Department Monroe Sheriff's Department Monroe Public Works Tavernier Fire Department FlOrida Keys Aqueduct Authority Private/Non-Governmental/Community Organizations' 1

American Red Cross Salvation Army Ocean Reef Department of Public Safety

' Federal Government Department of Homeland Security Department of Justice

Private Company Florida Power and Light I

Section 1: Exercise Overview 2011 TPNPP REP Exercise 8

Homeland Security. Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise Section 2: Exercise Design Summary 2.1 Exercise Purpose and Design DHS FEMA administers the REP Program pursuant to the regulations found in Title 44 Code of Federal Regulations (CFR) parts 350, 351 and 352. 44 CFR 350 codifies 16 planning standards that form the basis for radiological emergency response planning for licensees and State, local, and tribal governments impacted by the EPZs established for each nuclear power plant site in the United States. 44 CFR 350 sets forth the mechanisms for the formal review and approval of State, local, and tribal goveMhment RERPs and procedures by DHS FEMA. One of the REP program cornerstones

established by these regulations is the biennial exercise of offsite response capabilities.

During these exercises State, local, and tribal governments demonstrate their abilities to implement their plans and procedures to protect the health and safety of the public in the event of a radiological emergency at the nuclear plant.

The results of this exercise, together with the review of the RERPs and procedures and the verification of the periodic requirements set forth in NUREG-0654/FEMA-REP-1 through the Annual Letter of Certification (ALC) and staff assistance visits, enable-FEMA to provide a statement with the transmission of this final After Action Report to the U.S. Nuclear Regulatory Commission (NRC) that State, local, and tribal plans and preparedness are: (1)'adequate to protect the health and-safety of the public lixingin the vicinity of the nuclear power facility by providing reasonable assurance that. appropriate protective measures can be taken offsite in the event of a radiological emergency, and (2) capable of being implemented.

The Florida Division of Emergency Management (FLDEM) participated in this exercise at the Miami-Dade EOC, State Emergency Operations Center (SEOC) and Florida Power and Light (FPL) Emergency Operations Facility (EOF) in Miami-Dade, FL.

The State of Florida formally submitted-the Radiological Emergency Response Plans (RERP) for the Turkey Point NPP to FEMA Region IV on August 26, 1983. FEMA approved the plans pursuant to 44 CFR 350 on February 15, 1984. The qualifying emergency preparedness exercise was conducted on February 10, 1':1 a:nd 12, 1982.

This REP exercise was evaluated on February 23, 2011 and included evaluations from the following OOS activities in Miami-Dade, Florida held on January 18-21, 2011:

  • Protective actions for schools 2.2 FEMA Exercise Objectives and Capabilities Capabilities-based planning allows for exercise planning teams to develop exercise objectives and observe exercise outcomes through a framework of specific action items that were derived from the Target Capabilities List (TCL). The capabilities listed below form the foundation for the organization of all FEMA Region IV REP Program Section 2: Exercise Design Summary 2011 TPNPP REP Exercise 9

Homeland Security Exercise and Evaluation Program (HSEEP)

I AAR 2011 Turkey Point Nuclear Power Plant REP Exercise objectives and observations in this exercise.

e, Emergency Operations Center Management: Is the capability to provide Multi-I Agency Coordination (MAC) for incident management by activating and operating an EOC for a pre-planned or no-notice event. EOC management includes EOC

- activation, notification, staffing, and deactivation; management, direction, control,.

  • and coordination of response and recovery activities; coordination of efforts among neighboring governments at each level and among local, regional" State, and Federal
  • EOCs; coordination of public information and warning; and maintenance of the information and communication necessary for coordinating response and recovery activities.

3

  • Emergency Public Information and Warning: Is the capability that includes public information, alert, warning and notification. It involves developing, coordinating, and disseminating information to the public, coordinating officials, and incident management and responders across all jurisdictions and disciplines effectively under all hazard conditions.

1

  • CitizenEvacuation and Shelter in Place: Is:the capability to prepare for, ensure communication of, and immediately execute the safe and effective sheltering-in-place 1

of an at-risk population (and companion animals), and -the organized and managed

  • evacuation of the at-risk population (and companion animals) to areas of safe refuge in response to a potentially or actually dangerous environment. In addition, this I

capability involves the safe reentry of the population where feasible.'

Emergency Public Safety and Security Response: Is the capability to reduce the 1

impact and consequences of an incident or major event by securing the affected area, including crime andrincident scene preservation, issues as appropriate, safely diverting the public from hazards, providing security support to other response operations and I

properties; and'sustaining operations from response through recovery. Public Safety and Security Response requires coordination among-officials from Law Enforcement (LE), Fire and Emergency Medical Services (EMS).:

Hazardous Materials Response and Decontamination: Is the capability to assess and manage the consequences of a hazardous 'materials release, either accidental or as part of a terrorist attack. It includes testing and identifying all likely hazardous substances onsite; ensuring that responders have protective clothing and equipment; conducting rescue operations to remove affected victims from the hazardous environment; conducting geographical survey searches of suspected sources or contamination spreads and establishing isolation perimeters; mitigating the effects of

'hazardous materials, decontaminating on-site victims, responders, andequipment; coordinating off-site decontamination with relevant agencies, and notifying

,environmental, health, and law enforcement agencies having jurisdiction for the incident to begin implementation of their standard evidence collection and investigation procedures.

Section 2: Exercise Design Summary 2011 TPNPP REP Exercise 1

10 I

Homeland Security'.Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise Additionally, each capability is linked to several corresponding activities and tasks to provide additional details. Based upon the identified exercise objectives, the: following capabilities and associated activities are:-

o Objective 1: Demonstrate the ability to provide emergency operations center management including direction and.control through the State and county EOCs.

Capability: EOC Management - Activate EOC/Multi-Agency Coordination Center (MACC)/ Initial Operating Facility (IOF); Direct EOC/MACC/IOF Tactical Operations; and Provide EOC/MACC/IOF Connectivity

  • Objective 2: Demonstrate the ability to provide protective action decision-making for State and County emergency workers and the general public through exercise play and discussions of plans and procedures.
  • Capability: EOC Management - Gatherand Provide Information; Identify and Address Issues; and Support and Coordinate Response
  • Capability: Emergency Public Information and Warning - Manage Emergency Public Information and Warnings; Activate Emergency Public Information, Alert and Warning, Notification Plans and Issue Emergency Warnings.
  • Objective 3: Demonstrate the ability to physically implement protective actions for State and county emergency workers and the general public, through exercise demonstration and discussion of plans and procedures.

. Capability: EOC Management - Direct EOC Tactical Operations; Gather and Provide Information; and Identify and Address Issues

  • Capability: Emergency Public Safety and Security Response -Activate Public Safety and Security Response; Control Traffic, Crowd, and Scene; and Command and: Control Public Safety and Security Response Operations
  • Capability: Citizen Evacuation and Shelter-in-Place - Direct Evacuation or In-Place ProtectionOperations; Activate Evacuation or In-Place Protection; Implement Evacuation Orders for General Population; Collect and Evacuate Population Requiring Assistance
  • Capability: Hazardous Materials Response and Decontamination - Direct Hazardous Material Response and Decontamination Tactical Operations; Activate Hazardous Material Response and Decontamination; Assess Hazard

.and Evaluate Risk; and Conduct Decontamination and Clean-up and Recovery Operations k Objective 4: Demonstrate the ability to activate the Prompt Alert and Notification System utilizing the PNS and EAS System through exercise play.

Capability: Emergency Public Information and Warning - Manage Emergency Public Information and Warnings; Activate Emergency Public Information, Alert and Warning, Notification Plans; and Issue Public Section 2: Exercise Design Summary 2011 TPNPP REP Exercise 11

Homeland Security Exercise and Evaluation Program (HSEEP)

I AAR 2011 Turkey Point Nuclear Power Plant REP Exercise I

Information.

,Objective 5: Demonstrate.the effectiveness of plans, policies and procedures in the 1

. ENC for joint (public and private sector) emergency information communications.

Capability: Emergency Public Information and Warning -.,Establish an ENC; Conduct ENC operations; Issue Public Information, Alerts, Warnings, and Notifications; Conduct Media Relations; and Provide Public Rumor Control..3 2.3 Scenario Summary The exercise was based on the following scenario of plant events provided by the licensee. Times were for planning purposes only.

The scenario begins with a vehicle fire at the Unit 4 lay down area. Upon arrival at the scene the fire brigade determines that the fire has not resulted in visible damage to any structures or equipment.

3 The vehicle driver is discovered to have minor injuries and medical assistance will be requested. The victimwill not require offsite medical attention. Due to the size and difficulty of the fire, offsite response should be requested and may be simulated. The l

Shift Manager should declare an Unusual Event per HUI. The fire. will be extinguished by the fire brigade after approximately 25-30 minutes.

3 After the fire is out a Reactor Coolant System (RCS) leak will develop and will be greater than the maximum charging capacity with letdown isolated. The Emergency Coordinator (Shift Manager) should declare an ALERT per FAI due to loss or potential loss of RCS.

The reactor will be manually tripped.

The Emergency Coordinator will determine that it is necessary to activate emergency I

response facilities. The Duty Call Supervisor will be notified to activate the Emergency Response Organization. The Charlie team will respond and staff emergency facilities.

3 Safety Injection will be initiated. MOV-3-864B will block flow from the Refueling Water Storage Tank (RWST) due to a mechanical failure of the valve. Safety Injection pumps will trip shortly afterwards. Hydraulic shock from the reactor trip will create a fuel element failure. Containment Building Radiation Monitors (RD-1401, -1402, and -

1403) will start to increase.

Emergency response teams will be dispatched to determine the reason for the lack of flow from the RWST.

Approximately 90 minutes after the reactor trip containment radiation levels have continued to rise and the size of the RCS leak increases. Conditions are met for the Emergency Coordinator to declare a SITE AREA EMERGENCY per FSI due to loss or Section 2: Exercise Design Summary 2011 TPNPP REP Exercise 12

Homeland Security.Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR potential loss of any two barriers.

As the event continues, reactor core temperatures and Containment High Range Radiation: Monitor (CHRRMS) readings will increase with corresponding fuel clad

'degradation.

,Approximately 90 minutes after SAE conditions are met, a Containment Purge Valve begins to leak with a corresponding increase in the Plant Vent SPING to greater than 3.0uCilcc. Conditions are met for the Emergency Coordinator to declare a GENERAL EMERGENCY per FG1 due to loss of any two barriers and loss or potential-lossof the third OR per RGI due to a valid reading on the Plant Vent SPIiNG greater than 3.OuCilcc.

Default PARS will be generated based on severe core damage plant conditions unless dose projection data is available to support notification within 15 minutes of the GE declaration.,

Field teams will be dispatched to measure and track the plume. Emergency response teams will continue to attempt to establish cooling to the reactor and evaluate the release and its impact. Once a dose projection has been completed, additional PARS will be generated based on the radiological release data. The release to the environment will last for 28 minutes at which time the Purge Valve leak will stop without intervention from emergency responders.

If Emergency response teams can find that the disc from MOV-3-864B is blocking flow from the RWST they may have time to establish flow from the RWST and initiate core cooling prior 'to the end of the exercise.

The exercise will be terminated when exercise objectives have been met.

Section 2: Exercise Design Summary 2011 TPNPP REP Exercise 13

Homeland Security Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise Section 3: Analysis of Capabilities 3.1 Exercise Evaluation and Results Contained in this section are the results and findings of the evaluation of all jurisdictions and functional entities that participated in the February 23, 2011 plume phase exposure EPZ exercise and OOS interviews anddemonstrations on January 18-21, 2011 and February 23, 2011.

3.2 Evaluation Summaries 3.2.1 State of Florida 3.2.1.1 State Emergency Operations Center Emergency Operations Center Management Capability Summary:

The Florida State Emergency Operations Center (SEOC) was activated and provided risk counties all necessary support to assist staff in the overall mission to protect life and property. Personnel were alerted and mobilized in a timely manner to activate the SEOC from a-cold call out to having all major Emergency Support Functions (ESF) positioned in 48 minutes. The State Emergency Response Team (SERT) Chief at the SEOC demonstrated command and control throughout the exercise. Numerous briefings kept staff up to date on conditions at the site as well as risk counties and the Florida Incident Management Team (IMT). Communications in and out of the SEOC were clear and well understood throughout the exercise. Mission assignments and other requests were received and promptly acted upon. The SERT Chief also reviewed the identified protective actions developed by the IMT and risk counties to ensure no areas were missed, or given an inappropriate protective action. The SEOC had sufficient equipment and supplies to support emergency operations. Numerous large screens displayed on the front and side walls were used to project national and local news, weather, Emergency Notification Forms (ENF), electronic maps and internal information systems which provided situational awareness, and current status information.

For this capability, the following REP criteria were MET: 1.a. 1, 1.c. 1, 1.d. 1, L.e. 1, 2.a. 1, 2.b.2 and 3.b. 1.

Emergency Public Information and Warning Capability Summary:

Staff members demonstrated complete competence and confidence in their responsibilities, and familiarity with operational plans and procedures. They exhibited a broad understanding of how best to employ resources in identifying and addressing immediate needs and implementing established programs. Procedures included coordination with internal and external agencies, media outlets, the general public and acting on mutual aid agreements with other Statewide Public Information Officers (PIO) for material and personnel resource support. The PIO explained how rumor control would be accomplished. They managed and notified internal and external resources, interested parties, and managed the Florida Emergency Information Line (FEWL), a 24 Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise 14

.Homeland Security Exercise and Evaluation Program (HSEEP)

I AAR 2011 Turkey Point Nuclear Power Plant REP Exercise hour public inquiry hotline. Questions were answered and forwarded tol appropriate

-agencies as accurate information became available. Attempts were' made to establish trends and resolve inaccurate information. During the exercise, the State:External Affairs Office (ESF-14), supported the SEOC, and published and posted five press releases with no observed shortcomings.

For this capability, the following REP criteria were MET: 5.a. 1, 5.b. I 3.2.1.2 Florida Incident Management Team I

Emergency Operations Center Management Capability Summary:

Direction and control by the: Florida IMT at the EOF was proactive, responsive and smooth. Cooperation and participation was evident among state and county decision-makers. The Emergency Management Directors (EMD) focused on their communities and projected this attribute at all times in the protective action decision-making process.

'The utility provided Protective Action Recommendations (PAR) on% a timely' basis. The State Coordinating Officer (SCO) facilitated decision meetings which allowed risk county decision-makers to quickly reach independent, coordinated decisions.

This newly activated facility was adjacent to both the utilities recovery operations room and the ENC. It was well designed with ample space and infrastructure to accommodate I

the mission.

Communications were challenged throughout the exercise. Wireless connectivity to the 3

internet failed at the beginning of the exercise but was rapidly replaced by connection to a wired network. In the Decision Room, conference calls to risk county'EOCss failed intermittently for a variety of reasons but were seamlessly replaced by a combination of I

hand-held radios and agency'supplied cell'phones:'

Constant focus on unfolding events by the SCO, BRC and county decision-makers helped ensure public safety.

For this capability, the following REP criteria were MET: L.a. 1, 1!.c. 1, 1.d. land 1.e. 1.

3.2.1.3 Dose Assessment

  • Hazardous Materials Response and-Decontamination Capability Summary:,

3 The State BRC successfully demonstrated the ability to assess the consequences of a hazardous materials release.

'3 The FPL EOF in Miami;, Florida, served as the interface between the utility and the responding State and local government organizations' Consistent with the State of Florida's Concept of Operations" as specified in the State's RERP, the Florida IMT was deployed directly to the EOF and was authorized to make administrative and technical decisions 'on behalf of the Governor. Similarly, senior BRC staff members also deployed 3

to the EOF and were responsible for conducting independent accident analyses to include Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise U

15 i

Homeland,Security Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise radiological dose assessment, development of PAR to protect the health and safety of the public and emergency workers, providingdirection and control for the State of Florida BRC, FTs, and: serving as the technical advisor to the Florida IMT.

The BRC performed independent accident analyses, utilizing all available information and resources to factor into the development of protective actions. This included the State of Florida BRCFTs data, the RASCAL dose projection computer model, plant status and associated technical information and recommendations developed and provided by the utility operator..

The utility also performed dose modeling by utilizing their in-house Class A Computer Model.. While some variationT in plant condition assumptions were input into the& dose models, both the utility and the: BRC concurred that the Environmental Protection Agency (EPA). Protective Action Guidelines (PAG) were exceeded at or beyond 7 miles from TPNPP. Consequently, the State and affected counties agreed upon public evacuation. 5 miles around TPNNP and 10 miles downwind in Sectors R, A, and B.

The BRC successfully demonstrated its capability to effectively conduct independent accident analyses in a manner consistent with the preservation of public and emergency worker health and safety."

For this capability, the following REP criteria were met: lal, lcl, ldl, lel, 2a1, 2bl, 2b2.

3.2.1.4 State,of Florida BRC Field Teams Hazardous Materials Response and Decontamination Capability Summary:.

This capability was successfully demonstrated by the State of Florida BRC FTs. The demonstration included conducting geographical survey searches for contamination and testing.

In accordance with the EOPA, some State of Florida BRC personnel were pre-positioned at the Florida City Substation along with the Mobile Environmental Radiological Laboratory (MERL), Sample Preparation Van (SPV), the Field Team Supervisor (FTS) trailer, radiation survey instruments, dosimetry and miscellaneous supplies. The FTS properly inventoried all equipmenit ind performed survey instrument pre-operational checks. An inconsistency in recorded' source check parameters was obseryved and discussed with the FTS and MERL supervisor. While performning instrument source checks it was noticed that the values posted on the instruments, for source check ranges differed from the values posted in'the check lists. The FTS verified that the, numbers posted in the check list were the values to use to verify' instrument operation. A discussion was held with State of Florida BRC personnel to establish how these numbers were obtained and why they differed fr6ro the calibration numbers. BRC stated that they would review this practice and determine if a better method for calculating a range for source check values could be derived.

Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise 16

Homeland Security Exercise and Evaluation Program (HSEEP)

I AAR.

2011 Turkey Point Nuclear Power Plant REP Exercise Field Operations Specialists (FOS) were pre-positioned in the area but did not arrive on scene until 0900. Three FTs were assembled and consisted of two FOS from different offices of the BRC. Each FT was issued a state law enforcementradios 8900 MHz radio, satellite radio and cell phones for communication, purposes. Field checks of:all radios were performed between the State of Florida BRC FTs and the MERL prior to deployment. Once the Field Team Director (FTD) took command he also performed coimn unication checks'with all State of Florida BRC FTs. Each State 'of Florida BRC FTs was provided with the necessary equipment, plans, maps and dosimetry to perform their missions. The MERL Supervisor conducted a detailed safety and radiological briefing and updated all personnel on plant status,.current conditions and potential changes prior to deploying the State of Florida BRC FTs.

All FOS personnel assigned to the State of*Florida BRC FTs were knowledgeable of their radiation exposure limits and actions to take if limits were exceeded or if KI was ordered to'be ingested. The FOS properly read their electronic dosimeters while in the field and logged all results on the proper forms.

3 The FTD maintained, good contact with theState of Florida BRC FTs and kept them up-to-date on the plant status. While deployed the State of Florida BRC FTs were well 3

managed to enable them to locate the plume. The FTD directed the State of Florida BRC FTs to take appropriate radiation measurements and air samples. The State of Florida BRC FTs was very knowledgeable of their equipment. The FOS worked together as a 1

team in reading the SOPs while performing their tasks to ensure the tasks were completed correctly; Several air samples and radiation surveys were successfully completed. and the results communicated to the FTS. All sample transfer and chain of custody'paperwork I

was appropriately demonstrated.

For this capability,the following REP criteria were MET: 3.a. 1, 3.b.1, 4.a. 1, 4.a.3.

3 3.2.1.4 Emergency News Center (ENC)

Emergency Public Information and Warning:

The agencies of the ENC successfully demonstrated this capability by developing, coordinating and disseminating emergency public information with a sense of urgency 3

and without undue delay. The ENC serves as the central point of contact for the distribution and release of information to the media during an emergency at TPNPP.

This fixed facility offers ample space for P1O and supplemental technical staff from the utility, State of Florida, Miami-Dade County, Monroe County and Federal agencies to perform the duties required of them.

The utility, State and risk county personnel arrived in accordance with procedures. There was no pre-positioning of ENC staff for this exercise. The arriving staff conducted communication checks with their respective EOC and jurisdictional leads. All means of 3

communication were operational and no failures were noted during this evaluation.

Established protocols were followed when preparing, coordinating and disseminating Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise 17 I

Homeland SecurityrExercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise news releases. News release preparation and coordination was exemplary and was complete in both English. and Spanish as required.

Th e" E8N Manager proved to be the catalyst for the coordination between the State and County PIOs in the ENC. The process for preparing and. distributing news releases varied among the PIOs. Each PIO had the capability for preparing and distributing news releases from the ENC. However, the PIOs operate independently coordinating approval

.of news releases through their. respective jurisdictions. Both FPL and Miami-Dade County had pre-scripted English and Spanish releases.

Spanish translation of news releases'and EAS messages was successfully demonstrated during the exercise. The Miami-Dade County PIOs and the FPL spokesperson were bi-lingual and capable of translating all written and verbal correspondence. Monroe County and the State of Florida do not have Spanish interpreters so Miami-Dade has accepted responsibility for interpreting information for them.

There were two media briefings during the exercise. Prior to each briefing, the ENC Manager and County spokespersons discussed and coordinated their message for the briefing. They discussed who would say what, and in which order the briefing would be conducted. A book containing 81 different canned slides was provided by the Emergency Broadcast Center (EBC) for the spokespersons to select from to help aid their briefings. The selected slides were then projected behind the spokespersons during their briefing.

A critical aspect of keeping the. public informed is ensuring the correct information is available and erroneous information is corrected and rumors controlled. The public inquiry: and rumor control function is performed in the State and county EOCs and not in the ENC.. In accordance with plans, rumor control information gathering in EOCs should be passed to the PIOs in the ENC for inclusion in media briefings. These actions were not observed or evaluated during this exercise due to exercise design. The applicable citizeninformation numbers.were provided to the. public during each mediai briefing and on all news releases.

For this capability the following criteria were met: 1.a. 1, 1.d. 1, L.e. and 5.b. 1.

Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise 18

Homeland Security Exercise and Evaluation Program (HSEEP)

I AAR 2011 Turkey Point Nuclear Power Plant REP Exercise 3.2.2 Risk Jurisdictions 3.2.2.1 Miami-Dade, Florida 3.2.2.1.1 Miami-Dade Emergency Operations Center (EOC)

I Emergency Operations Center Management Capability Summary:.

Miami-Dade Department of Emergency Management (DEM) and EOC personnel successfully demonstrated the ability to provide Multi-Agency Coordination (MAC) for an incident at TPNPP.

The EOC is a state-of-the-art facility, well equipped to support emergency operations.

Overall direction and control for county response was provided by the DEM-Director who also had authority to make PADs. Following the Alert declaration by TPNPP, the DEM Director relocated to the EOF and delegated management of the EOC to the DEM Deputy Director.

According to the EOPA, staff was prepositioned in the EOC. At 0828, the utility notified affected jurisdictions that the plant had declared a NOUE. Following the decision of the DEM Director to activate the EOC, the EOC Branch Directors followed procedures to 1

alert appropriate agency representatives to respond.

Since the initial call was received during business hours, DEM staff was immedciately 3

available in the EOC. The Operations Section Chief provided a facility, briefing,-

organization overview and WebEOC orientation to EOC staff at 0846.: The Deputy Operations Section Chief briefed EOC staff about the NOUE and plant status at 0901.

The DENM Director and Deputy Director frequently. instructed EOC staff to anticipate future actions if the incident escalated and to monitor events and conditions in the county which could affect their response. Frequent planning meetings were held with command and general staff to discuss response strategies. The Planning Section Chief monitored and tracked incident status.

3 PADs were coordinated among Miami-Dade, Monroe County and Florida BRC. These decisions were implemented by the EOC staff in a timely manner. The Operations Section Chief provided frequent briefings to EOC staffregarding incident status, and decisions made by DEM Director and followed up with EOC Branch Directors to ensure proper actions were taken.

3 For this capability, the following REP criteria were met: l.a. 11.c. 1,1.d&l, 1.e. 1, 2.a. 1, 2.b.2, 2.c.1, 3.a. 1, 3.b.1, 3.c.1, 3.c.2 and 3.d..l...

3.2.2.1.2 Miami-Dade Emergency Public Information and Warning Capability Summary:

Miami-Dade DEM and EOC-personnel successfully demonstrated the ability to provide the media and the public with emergency information and warnings.

Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise 19

Homeland Security.Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise Emergency public information and warnings were managed by the PIO staff at the EOC as directed by the DEM Director and Deputy Director. The PIO staff was not only -

responsible for preparing and distributing press releases and EAS messages, but also for activating the county siren system. Appropriate pre-scripted mess"ages ini English and Spanish were selected and promptly distributed to the media and to the ENC once it was activated. The Miami-Dade County PIO and the FPL spokesperson were bilifigual and capable of translating all written and verbal correspondence including releases for Monroe County and the State~of Florida. All selected messages were coordinated with Monroe County prior to their release. Media outlets were monitored throughout the Iexercise on ten televisions dedicated to media monitoring.

Siren actiYation and release of EAS messages was accomplished in a timely manner after PADs& were made by the DEM Director. Following the failure (controller inject) of four sirens to sound during the. first activation, EOC staff promptly directed personnel at the Evacuation Command Post (ECP) to perform backup route alerting in the failure areas.

The process for preparing and distributing news releases varied among the PIO's. Each PIO had the capability for preparing and distributing news releases from the ENC.

However, the PIO's operate independently whilecoordinating approval oftheir new releases through their respective jurisdictions.

The 311 Center fielded several public inquiries throughout the exercise. All questions

.were properly answered or forwarded to the appropriate agency. The 311 Center received late registrants for the specialneeds list, and those were forwarded tothe Human

,Serv 6esiBranch Director to ensure they were considered during the evacuation. The representative in the 311 Center maintained close and frequent contact with the PIOs regarding the nature and content of the calls received. The PIOs provided the 311! Center with all press releases and EAS messages to keep them up to date with the incident. No rumors or trends were identified during the exercise.

For this capability, the folloWingREP criteria were met: 5.a. 1, 5.a.3 :and 5.b. 1.

3.2.2.1.3 Miami-Dade Traffic ControlPoints (TCP)

Public Safety and Security Response Capability Summary:

Miami-Dade Public Safety Branch Director'(PSBD) and the MDPD successfully demonstrated through discussions, the ability to set up and secure Traffic Control'Points (TCP) and limit emergency worker exposure to, radiation.

At Alert Emergency Classification Level (ECL), police officers are staged at EC).

Information is exchanged through radio communications from officers at the ECPs to officers in the field. As directed, officers ate assigned to set up and man an assigned TCP. Upon direction from the Director, officers would then ingest-KI.

Police personnel tasked to support TCPs are also given a briefing on specifics such as Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise 20

Homeland Security Exercise and Evaluation. Program (HSEEP) 1 AAR 2011 Turkey Point Nuclear Power Plant REP Exercise I

addresses of reception centers, methods to clear impediments, contacts for wreckers and public works facilities for signage or barrier support. Each officer-isprovided a~copy of the TCP plan. Questions were asked about clearing impediments. Answers were direct and to the point.

When interviewed about radiation exposure control, the Miami-Dade PSBD stated officers would receive their radiation safety.briefing, all required dosimetry and KI with an instruction and exposure record card. The safety briefing would cover exposure limits, as well as, the hazards of taking KI, precautions not to take KI if allergic to shell fish, and a reminder not to take the issued KI until directed to do so. Instructions would also be provided on how to fill out the exposure record card for both dosimeter readings and consumption of KI when directed.

'For this capability, the following REP criteria were MET: 3.d.1 and 3.d.2.

3.2.2.1.4 'Miami-Dade Backup Route Alerting 1

Emergency Public Information and Warning Capability Summary:

Backup Route Alerting was successfully demonstrated by interview with the Miami-Dade PSBD and representatives of the MDPD. In accordance with the EOPA, no routes were actually run and no traffic officers Were interviewed At 1135, the Miami-Dade PSBD was notified that four sirens had failed and backup route alerting was necessary. This information was passed to the MDPD representative who stated he would begin researching a book of maps depicting siren coverage. After reviewing the maps and identifying the areas not covered.by overlapping sirens, the I

appropriate maps would be faxed to the police representative in the ECP.

A phone call would then be made out to the ECP to discuss the areas that need back up route alerting., The Miami-Dade PSBD and MCPD-both understood the sense of.urgency and.45 minute completion time once the failure was discovered. The need to verify prescripted message content before alerting was also discussed.

For this capability, the following REP criterion was MET: 5.a.3.

I

!I Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise I

21

,.I

Homeland Security. Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise 3.2.2.1.5 Waterway Warning Public Safety and Security Response:

The Miami-Dade PSBD successfully demonstrated through interview, the ability to clear

.,Miami-Dade waterways. The. interview was conducted with the Miami-Dade PSBD and

..representatives from the MDPD Marine Patrol, US Coast Guard, Florida Fish and Wildlife and the Biscayne National Park Services (NPS) as agreed to in the EOPA.

MiamiDade Police is the lead agency for coordinating waterway warning and evacuation:

the Public Safety Branch Director stated that emergency workers will receive their radiation safety briefing and required dosimetry, KI, instruction and exposure record cards. A safety briefing will be conducted to cover exposure limits, KI ingestion and KI precautions. Instructions for completing exposure record cards will also be included.

Coast Guard Sector Miami is responsible for broadcasting EASmessages on VHF~radio channels 16 and 23. Additionally, and as available, rotary wing aircraft will be utilized with the public address system to sweep the area advising vessels to clear the area and monitor maritime safety broadcasts and National Oceanic and Atmospheric:,

Administration National (NOAA) Weather Radio for further information. MDPD Marine Patrol and the NPS will use the public address system to advise boaters of the EAS messages, and direct boaters to the Matheson Hammock Marina.

For this capability, the following criteria were met: 5.a. 1, 5.a.3, 5.b. 1 3.2.2.1.6 Miami-Dade Schools Citizen Evacuation and Shelter in Place Capability Summary:

Miami-Dade Public School Principals successfully demonstrated through interviews, the ability to evacuate or shelter in place students at the following schools: Avocado ES, Bell-Aire ES,-Campbell Drive ES, Caribbean ES, Centennial MS,**Chapman ES, Devon Aire K-8, Florida City ES, Gilbert Porter ES, Hammocks MS, Homestead MS, Homestead Senior HS, Irving and Beatrice Peskoe ES, Laura Saunders ES, Redland MS, Redondo ES, South Dade Adult School, South Dade-HS, Whigham ES, Whispering Pines ES.

Principals at Miami-Dade Public Schools were interviewed throughout the week of January 17, 2011. They were fully aware of their responsibilities should an incident occur at the TPNPP. A Critical Incident Plan (CIP) was presented from each school. The plans included direction and control as well as appropriate coordinating actions for students and staff during an incident. School administration and staff are responsible for the response effort. Students and families are provided school response procedures at the beginning of each school year. Plans are updated and redistributed if changes become necessary.

Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise 22

Homeland Security Exercise and Evaluation Program (HSEEP)

AAR 2011 Turkey Point Nuclear Power Plant REP Exercise I

Connect-ED is a communication system that enables school officials. to-quickly contact all parents, faculty.and staff using, designated phone numbers, with personalized. voice and text messages describing an incident at the school. A pre-scripted message is loaded in the system concerning an incident at TPNPP. The message can be modified based upon school protective actions and rapidly sent to parents informing them of the changes.

  • Based upon plant conditions and discussions with each Principal, schools 'will relocate students. Every student is loaded onto school busses and transported to a designated host school where parents will pick up their children. School bus transportation is arranged through the District Superintendent. Miami-Dade Transit Authority will provide backup transportation services if there are not enough school buses available.

For this capability, the following REP criterion was MET: 3.c.2 3

3.2.2.2 Monroe County, Florida 3.2.2.2.1 Tavernier Emergency Operations Center 1

Emergency Operations Center Management Capability Summary:

Monroe County REP Administrator and EOC personnel successfully demonstrated the I

ability to provide MAC for an incident at TPNPP.

The Monroe County REP Administrator demonstrated capable direction and control of I

the.REP EOC throughout the exercise. The support organizations received continuous information on the developing situation at TPNPP and queried on their response status.

All of the support organizations were readily identifiable by title and telephone extension which provided easy location and contact information. Sufficient reference material was available at each workstation. Wall displays of maps and plant status were available for common viewing. There was ongoing coordination with the EMD who. was deployed to the EOF and actively involved with the decision making process. Emergencycworkers were interviewed and knowledgeable of assigned equipment and procedures related to radiation safety. The Monroe County REP EOC staff demonstrated a high level of competence, in thee ability to protect the health and safety 'of thepublic and emergency workers in the event of an incident at TPNPP.

3 The Monroe County REP EOC was recently relocated to the Taverinier Fire Station. The facility is well equipped to support extended operations should an incident occur, at TPNPP. There was adequate workspace and comfort support for personnel. A backup power system is in place with a fixed diesel generator that is regularly maintained by the county. The addition of a common display of WebEOC would enhance the dissemination of information.

For this capability, the following criteria were met: L.a. 1,.b. 1, L. 1, 1.d. 1, L.e. 1, 2.a. 1, 2.b.2, 3.a.1, 3.b.1, 3.d.1, 5.a.3 and 5.b.l1 Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise 23

Homeland Security Exercise and Evaluation Program (HSEEP)

AAR I.

2011 Turkey Point Nuclear Power Plant REP Exercise Emergency Public Information and Warning Capability Summary:

Monroe County EOC personnel successfully demonstrated the ability to provide the

  • media~and the public with emergency.information andwarnings...

Emergency public information and warnings were managed by the PIO staff at the EOC as directed by the Monroe County EM Planner and the County EMD at the EOF. PIO staff prepared and distributed press releases and EAS messages. Appropriate pre-scripted

-messages were promptly distributed to the, media and to the ENC once it was activated.

Messages were coordinated with Miami-Dade prior to their release.

Fo-r this capability, the following REP criteria were MET: 5.a. 1, and 5.b. 1.

3.2.2.2.2 Ocean Reef Traffic Control Points Public Safety and Security Response Capability Summary:

Ocean Reef Fire Chief (ORFC), Monroe County Sheriff's Department and the Florida Highway Patrol (FHP) successfully demonstrated the ability to set up TCPs and remove, any roadway impediments.

The ORFC stated citizens on the island are first warned of an incident by Reverse 911 and police officers would patrol the streets with mobile speakers as back up. Heistated that Ocean Reef has 1400 homes and expected word of mouth tO travel quickly.' During the interview it was determined that support agencies would be available and. had the appropriate equipment and resources needed to support this mission. Coordinating agency representatives undeistood-their roles'and responsibilities in support 'of Ocean Reef TCPs. Each agency demonstrated adequate knowledge resolve impediments to 'the flow of traffic and where to locate necessary resources to remove them.

The ORFC demonstrated through' ifiterview the ability to successfully resolve a'traffic impedimeht, should an ev dcuation occur at the TPNPP. The ORFC, in coordination with the Monroe County Sheriff's Department and Florida Highway Patrol (FHP) sfated that at SAE the Captain for the Monroe County Sheriff'§s Department discussed impediment rem6val if an evacuation were to occur due to an incident at TPNPP. He' demonstrated thorough knowledge and understanding for the coordimition necessary to remove impediments. Additionalresources would be processed through the Tavernier EOC and FHP would assist in the evacuation as well. If necessary, mutual aid would be called upon to assist, with impediment removal.

This capability was demonstrated through interview at the Tavernier EOC, in accordance

'with the EOPA. For this capability, the following REP criteria'were MET: 3.d. 1 and 3.d.2.

Section 3: Analysis of Capabilities 2011 TPNPP REP Exercise 24

I I

I I

i I

I I

U I

I I

i I

U I

I

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR Section 4: Conclusion Officials and representatives from the State of Florida; risk counties of Miami-Dade and Monroe, FPL; as well as numerous volunteers participated in this exercise. The cooperation and teamwork of the participants was evident throughout all phases of the exercise. FEMA wishes to acknowledge the efforts of the many individuals who participated and made the exercise a success. Protecting the public health and safety is the full-time job of some of the exercise participants and an additional assigned responsibility for others. Additionally, others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities.

State and local emergency response organizations demonstrated knowledge of their emergency response plans and procedures and successfully implemented them. During this exercise, no Deficiencies or Areas Requiring Corrective Action were identified.

Section 4: Conclusion 2011 TPNPP REP Exercise 25

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR This page is intentionally blank Section 4: Conclusion 2011 TPNPP REP Exercise 26

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey point Nuclear Power Plant REP Exercise AAR Appendix A: Exercise Timeline Emergency:

ClassificationTime That No ti6fin Was Received or Action-Was Taken SEhneigency Classification

,Tm tlt County County Unusual Event 0815 0815 0828 0826 Alert 0908 0921 0921 1000 0921 0923 Site Area Emergency 1033 1054 1036 1046 1048 1044 General Emergency 1212 1235 1213 1215 1225 1220 Simulated Rad. Release Started 1200 1235 1236 1232 1234 1235 Simulated Rad. Release Terminated 1230 1315 1305 Ongoing Ongoing 1303 Facility Declared Operational 1055 1020 1032 1016 1000 0950 Declaration of Em ergency: State 1049 1120 1119 Declaration of Emergency: Miami 1100 1100 Dade Declaration of Emergency: Monroe 1122 1100 State Control Transfer to IMT 1102 1102 Exercise Terminated 1339 1333 1330 1339 1335 1330 Early Precautionary News Release: Stay Tuned Alert 1015 1015 1015 1015 1st Protective Action Decision: Stay Tuned SAE 1100 1100 1100 1100 ist Siren Activation 1105 1105 1105 1105 1st EAS Message 1

1110 1110 1110 1110 2nd Protective Action Decision:

Miami-Dade: Evacuate 2,3, 4,5,.6, 7; Shelter in Place 8, 1243 1243 1243 1243 9; 10 mile marine blockade Monroe: Shelter in Place 10 2nd Siren Activation 1255 1255 1255 1255 2nd EAS Message 1255 1255 1255 1255 KI Administration Decision: Emergency Workers and 1243 1

1 General Public in Evacuation Areas 1243 1243J 1243 1243 AAR Appendix A: Exercise Timeline 2011 TPNPP REP Exercise 27

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR Appendix B:

Table 2 DATE AND SITE: February 23, 2011 - Turkey Point Nuclear Power Plant ELEMENT/Sub-Element FLDEM FL BRH Miami-Dade Monroe County County

1. EMERGENCY OPERATIONS MANAGEMENT L.a. 1. Mobilization M

M M

M L.b.l.

Facilities M

M I.c. 1.

Direction and Control M

M M

M I.d.l.

Communications Equipment M

M M

M 1.e. 1.

Equipment & Supplies to Support Operations M

M M

M

2. PROTECTIVE ACTION DECISION MAKING 2.a.1.

Emergency Worker Exposure Control M

M M

M 2.b.l.

Rad Assessment & PARs Based on Available Information M

2.b.2.

PARs & PADs for the General Public M

M M

M 2.c. 1. Protective Action Decisions for Special Populations M

2.d.1.

Rad Assessment & Decision Making for Ingestion Exposure 2.e.1.

Rad Assessment & Decision Making for Relocation, Re-entry & Return

3. PROTECTIVE ACTION IMPLEMENTATION 3.a. 1.

Implementation of Emergency Worker Control M

M M

3.b. 1. Implementation of KI Decisions M

M M

3.c.1.

Implementation of PADs for Special Populations M

3.c.2.

Implementation of PADs for Schools M

3.d.1.

Implementation of Traffic and Access Control M

M 3.d.2.

Impediments to Evacuation and Traffic & Access Control M

M 3.e.1.

Implementation of Ingestion Decisions Using Adequate Info 3.e.2.

Implementation of EP Decisions Showing Strategies & Instructional Materials 3.f.l.

Implementation of Relocation, Re-entry & Return Decisions

4. FIELD MEASUREMENT and ANALYSIS 4.a.1.

Plume Phase Field Measurement & Analysis Equipment M

4.a.2.

Plume Phase Field Measurement & Analysis Management M

4.a.3.

Plume Phase Field Measurements & Analysis Procedures M

4.b.l.

Post Plume Field Measurement & Analysis 4.c.1.

Laboratory Operations M

5. EMERGENCY NOTIFICATION & PUBLIC INFO 5.a.I.

Activation of Prompt Alert and Notification M

M M

5.a.3.

Activation of Prompt Alert and Notification Backup Alert and Notification M

M 5.b.l1.

Emergency Info and Instructions for the Public and the Media M

M M

6. SUPPORT OPERATIONS/FACILITIES 6.a.1.

Monitoring and Decon of Evacuees and EWs and Registration of Evacuees 6.b.l.

Monitoring and Decon of Emergency Worker Equipment 6.c.I1.

Temporary Care of Evacuees 6.d.I1.

Transport and Treatment of Contaminated In~jured Individuals LEGEND:

A=ARCA M = Met D = Deficiency AAR Appendix B: Table 2 2011 TPNPP REP Exercise 28

t Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR Appendix C: Exercise Evaluator and Assignments TURKEY POINT NUCLEAR POWER PLANT FEBRUARY 23, 2011

'URIS DICTIO SEQUENCE KEVin Key FRMA 1

State of Florida In Sequence Kevin Keys FEMA I1.a..1, I.c.l, i.d.i, L~e.1, (SE C)

Odis Spencer 2.a. 1, 2.b.2, 5.a. 1, 5.b.1I FL SMT LEAD In Sequence Obhie Robinson FEMA 1.a. 1, 1.c. 1, 1.d. 1, 1.e. 1, (Miami) 2.a.1, 2.b.2, 5.a.1, 5.b.1 FL SMT In Sequence Gerald McLemore FEMA l.a.1, 1.c.1, 1.d.1, l.e.1, 2.a.1, 2.b.2, 5.a.1, 5.b.1 Emergency News In Sequence Robert Spence FEMA 1.a. 1, 1.e. 1, 5.b. 1 Center (ENC) Lead Ron Shaw OJT ENC In Sequence JT Ackerman FEMA 1.a.1, 1.e. 1, 5.b.1 Public Information -

In Sequence Alex Sera FEMA 5.b. 1 Spanish Language ENC Dose Assessment In Sequence Robert Trojanowski NRC 1.a. 1, 1.c. 1, 1.d. 1, L.e. 1, 2.a.1, 2.b.1, 2.b.2, 3.a.1, 4.a.2 Emergency In Sequence Robert Trojanowski NRC l.c. 1, 1.d. 1, L.e. 1, 2.b. 1 Operations Facility Mobile Laboratory In Sequence Brad McRee FEMA 1.e. 1, 3.a. 1, 4.c.1 Field Team r

(Lead)

In Sequence Joe Hatworth FEMA 1.d.1, Le.b1, 3.a.1, 3.b.1, 4.a. 1, 4.a.2, 4.a.3 Field Team 2 In Sequence Marcy Campbell FEMA 1.d. 1, Le. 1, 3.a. 1, 3.b. 1, 4.a. 1, 4.a.2, 4.a.3 Emergency In Sequence John Fill FEMA 2.a.1, 2.b.2,2.c.1 Operations Center Lead Emergency In Sequence Walt Cushman FEMA 1.a. 1, 1.c. 1,1.d. 1, 1.e. 1 Operations Center Emergency In Sequence Matt Bradley FEMA 3.a.1, 3.b.1, 3.c.1, 3.c.2 Operations Center Water Clearance In Sequence, by Walt Cushman FEMA

5. a. 1, 5.a. 3, 5.b.1I interview in EOC Traffic Control In Sequence, by Matt Bradley FEMA 3.d. 1, 3.d.2 Points interview in EOC Protective Action for OOS Lisa Rink FEMA 3.c.2 Schools - Lead (#1)I Protective Action for OOS IRobert Spence FEMA 3.c.2 AAR Appendix C: Exercise Eval & Assign 2011 TPNPP REP Exercise 29

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR Protective Action:-for;:: i'OOS

.,.Gerald Mcemnorei,.: FEM I 3i..

Schools (#3) : * : ' *,

Monroe County ili//~/*

il Emergency In sequence Jon Sandberg

FEMA, 1.a. i, 1.b. 1, 1.c. 1, 1.d. 1, Operations Center L e. 1, Lead*-

Emergency In sequence Lorenzo *Lewis FEMA 2.a. 1, 2.b.2, 3.a. 1, 3.b. 1, Operations Center 5.a.3 County Warning In Sequence, by Lisa Rink FEMA 5.a.1, 5.b.1 Point (Ocean Reef interview in EOC.

3.d.1, 3.d.2 Monroe County)

Traffic Control Points 1

1 I

I I

1 I

I 1

AAR Appendix C: Exercise Eval & Assign 2011 TPNPP REP Exercise 30

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR Ap'pendixD:Aoym

ýcronym Meaning AAR' After Action Report. -,*...

.,,",ALC

-Annual. Letter iof'Certification ARC American Red Cross ARCA Area Requiring Corrective Action ARES Amateur Radio for Emergency Services BRC Bureau of Radiation Control CFR Code of Federal Regulations CHRRMS Containment High Range Radiation Monitor DHS Department of Homeland Security DRD Direct-Reading Dosimeter DSS Department of Social Services EAL Emergency Action Level EAS Emergency Alert System ECL Emergency Classification Level ECP Evacuation Command Post EEG Exercise Evaluation Guide EMA Emergency Management Agency EMD Emergency Management Director EMS Emergency Medical Services ENC Emergency News Center ENF Emergency Notification Form EOC Emergency Operations Center EOF Emergency Operations Facility ENC Emergency News Center ENN Emergency Notification Network EOPA Extent of Play Agreement EPA U.S. Environmental Protection Agency EPZ Emergency Planning Zone ERDS Emergency Response Data System ERP Emergency Response Plan ESF Emergency Support Function EW Emergency Worker EWD Emergency Worker Decontamination AAR Appendix D: Acronyms 2011 TPNPP REP Exercise 31

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR A.cronyM'.' 1%

Meaning FEIL Florida Emergency Information. Line FEMA Federal Emergency Management Agency.,.,:.

FHP Florida Highway Patrol FL DEM Florida Division of Emergency Management FMT Field Monitoring Team, FOS Field Operations Specialist FOUO For Official Use Only, FPL Fiorida Power and Light, FRMAC Federal Radiological,Monitoring and Assessment Center' FT Field Team FTD Field Team Director FTS Field Team Supervisor GAR Governor's Authorized Representative GE General Emergency GIS Geographic Information System GM Geiger-Muller (detector)

GPS Geographic Positioning System, HAZMAT Hazardous Materials-HSEEP Homeland Security Exercise. andEvaluation Program HQ Headquarters IC Incident Commander,.

ICP Incident Command Post ICS Incident Command System IOF Initial Operations Facility IP Improvement Plan IPZ Ingestion Pathway Zone JIC Joint Information Center KI Potassium Iodide.

LE Law Enforcement LP-1 Local Primary (EAS Radio Station)

MAC

-Multi-Agency Coordination MACC Multi-Agency Coordination Center MDPD Miami-Dade Police Department MERL Mobile Environmental Radiological Laboratory I

I I

I I

I I

I I

I I

I I

I I

I I

AAR Appendix D: Acronyms 2011 TPNPP REP Exercise 32

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR roiiY'rn,%:'-

ng,ý

'[-1

--Sle ni MOC

.Mobile Operations Center MOU Memorandum of Understanding mR milliroentgen rinR/h "milliroentgen per hour NAWAS National Warning System NGO Non-Governmental Organization NIMS National Incident Management System NOUE Notification of Unusual Event NPP Nuclear Power Plant NRC U.S. Nuclear Regulatory Commission NUREG-NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria 0654 for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980 OC Operations Chief OOS Out of Sequence OP Operational Procedure ORO Offsite Response Organization PA Public Announcement PAD Protective Action Decision PAG Protective Action Guide PAR Protective Action Recommendation P1O Public Information Officer PPE Personal Protective Equipment, PRD Permanent Record Dosimetry R

Roentgen RAC Regional Assistance Committee RACES Radio Amateur Civil Emergency Service RCS Reactor Coolant System REA Radioactive Emergency Area REM Roentgen Equivalent Man REP Radiological Emergency Preparedness REPP Radiological Emergency Preparedness Program RERP Radiological Emergency Response Plan:

R/h Roentgen(s) per hour AAR Appendix D: Acronyms 2011 TPNPP REP Exercise 3.3

Homeland Security Exercise and Evaluation Program (HSEEP)

AAR T.

2011 Turkey Point Nuclear Power Plant REP Exercise I

Meain RO

]Radiological Officer,.

RWST Refueling Water StoraRe Tank SAE S'ite Area Emergency SPV Sample Procedure Van SCO State Coordinating Officer SEOC State Emergency Operations Center SERT State Emergency Response Team SMRAP Southern Mutual Radiological Assistance Plan' SMT State Management Team SOP Standard Operating Procedure TCL Target Capabilities List TCP Traffic Control Point THD Technological Hazard Division TLD Thermoluminescent dosimeter TPNPP Turkey point Nuclear Power Plant USDA U.S. Department of Agriculture UTL Universal Task List VFD Volunteer Fire Department I

I I

I I

I I

I I

I I

I I

I I

U I

AAR Appendix D: Acronyms 2011 TPNPP REP Exercise 34

Homeland-Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR Appendix E: Exercise LOcations Exercise Locations Florida Division of Emergency Management 2555 Shumard Oak Boulevard Tallahassee, Florida 32399 FP&L EOF 9250 West Flagler Street Miami, FL 33174.

(305) 552-3552 Miami-Dade County EOC 9300 NW 41st Street Miami, FL 33178 (305) 468-5400 Monroe County EOC 151 Marine Avenue Tavernier, FL 33070 (305) 852-9860 Out of Sequence Locations Florida City ES 364 NW 6THIAVENUE FLORIDA CITY, FL 3303 (305)247-4676 Homestead'Senior HS 2351 SE 12TH AVENUE HOMESTEAD, FL 33034 (305)245-7000 Laura Saunders ES 505 SW 8 STREET HOMESTEAD, FL 33030 (305)247-3933 Homestead MS 650 NW 2ND AVENUE HOMESTEAD, FL 33030 (305)247-4221 South Dade Adult School 109 NE 8TH STREET HOMESTEAD, FL 33030 (305)248-5723 Redondo ES 18480 SW 304 STREET HOMESTEAD, FL 33030 (305)247-5943 Gilbert Porter ES 15851 SW 112 STREET MIAMI, FL 33196 (305)382-0792 AAR Appendix E: Exercise Locations 2010 FNP REP Exercise 35

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR Irving and Beatrice Peskoe ES 29035 SW 144TH AVENUE HOMESTEAD, FL-33033 (305)242;8340 Avocado ES 16969 SW 294TH STREET HOMESTEAD, FL 33030 (305)247-4942 Chapman ES 27190 SW 140TH AVENUE HOMESTEAD, FL 33032 (305)2451-1055 South Dade HS 28401 SW 167TH AVENUE MIAMI-DADE, FL 33030 (305)247-4244 YMAACD @MacArthur South 13990 SW 264TH STREET NARANJA, FL 33032 (305)258-7200 Leisure City 14950 SW 288TH STREET HOMESTEAD, FL 33033 (305)247-5431 Hammocks MS 9889 HAMMOCKS BOULEVARD MIAMI, FL 33196 (305)385-0896 Campbell Drive ES 15790 SW 307TH STREET HOMESTEAD, FL 33033 (305)245-0270 Bell-Aire ES.

10205 SW 194TH STREET MIAMI, FL 33157

.(305)233-5401.

Whispering Pines ES 18929 SW 89TH ROAD MIAMI, FL 33157.1 (305)238-7382 Whigham ES 21545 SW 87 AVENUE MIAMI, FL 33189 (305)234-4840 Centennial MS 8601 SW 212TH STREET MIAMI, FL 33189 (305)235-1581 Caribbean ES 11990 SW 200 STREET MIAMI, FL 33177 (305)233-7131 Redland MS 16001 SW 248 STREET HOMESTEAD, FL 33031 (305)247-6112 Devon Aire K-8 10501 SW 122ND AVENUE MIAMI, FL 33186 (305)274-7100 1

I I

I 1

t I

I I

I I

I ES-Elementary School, MS-Middle School, High School AAR Appendix E: Exercise Locations 2011 TPNPP REP Exercise 36

Homeland Security Exercise and Evaluation Program (HSEEP) 2011 Turkey Point Nuclear Power Plant REP Exercise AAR Appendix F: Exercise Planning Team Leadership.

AgencyName.

Florida Division of Emergency Management Tracy Poole Roger Rankin FL BRC Charlie Adams Miami-Dade Emergency Management Niel Batista Monroe County Emergency Management Irene Toner Vince Kalson FEMA Region IV Randall Hecht Lisa Rink Florida Power and Light Don Mothena Brian Carberry Mitch Epstein AAR Appendix F: Exercise Planning Team Leadership

-37 2011 TPNPP REP Exercise