Thomas G. Mogren Manager - Engineering Services CENG a joint venture of Consteflatlon 4Fý eD Energy-01 R.E. Ginna Nuclear Power Plant, LLC 1503 Lake Road Ontario, New York 14519-9364 585.771.5208 585.771.3392 Fax Thomas.Moqren@,cenqllc.com July 29, 2011 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTENTION:
SUBJECT:
Document Control Desk R.E. Ginna Nuclear Power Plant Docket No. 50-244 Response to Request for Additional Information Re: Fourth Interval Inservice Inspection Proaram Relief Requests Nos. ISI-02 and ISI-03 (1) Letter from P. Swift, Ginna LLC, to NRC Document Control Desk, dated December 16, 2010,
Subject:
10 CFR 50.55a Request ISI-02 and ISI-03:
Relief From Impractical Examination Coverage Requirements Pursuant to 10 CFR50.55a(g)(5)(iii) for the Fourth Interval Inservice Inspection (ISI)
Program. (Agencywide Documents Access and Management System (ADAMS) Accession No. ML103620105)
References:
(2) Letter from D. V. Pickett, NRC, to J. T. Carlin, Ginna LLC, dated April 13, 2011,
Subject:
R.E. Ginna Nuclear Power Plant -Request For Additional Information Re: Fourth Interval Inservice Inspection Program Relief Requests Nos. ISI-02 and ISI-03 (TAC NOS. ME5248 and ME5249).
(Agencywide Documents Access and Management System (ADAMS)
Accession No. ML110880297)
In Reference 1, R.E. Ginna Nuclear Power Plant, LLC (Ginna LLC) requested relief from impractical examination coverage requirements pursuant to 10 CFR50.55a(g)(5)(iii) for the Fourth Interval Inservice Inspection (ISI) Program. This 10 CFR 50.55a request is for weld examinations performed during the 4 th 10-Year ISI Interval, where the required coverage of
'essentially 100 percent' could not be obtained, when examined to the extent practical in accordance with ASME Section XI Code Case N-460 "Alternative Examination Coverage for Class 1 and 2 Welds". The basis for the 10 CFR 50.55a request is that compliance with the specified requirements is impractical as described in Relief Request ISI-02 and ISI-03. This request for the Fourth Interval Inservice Inspection (ISI) Program, ended December 31, 2009.
In Reference 2, the Nuclear Regulatory Commission (NRC) sent a request for additional information (RAI). The questions in the RAI and the corresponding responses are in the attached enclosure.
ACD q7 014
Document Control Desk July 29, 2011 Page 2 There are no regulatory commitments contained in this letter. Should you have questions regarding this matter, please contact Thomas Harding (585) 771-5219, or Thomas. hardinair*hcenqllc.com.
Very truly yours, Thomas Mogren
Enclosure:
Response to Request for Additional Information Regarding Relief Request ISI-02 and 03 cc:
W. M. Dean, NRC D. V. Pickett, NRC Resident Inspector, NRC (Ginna LLC)
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request ISl-02 Question No. 1 Please provide the edition and addenda of the ASME Code,Section XI, Appendix VIII that was used for these examinations.
Response
ASME Section XI 1995 Cat Item Summary No.
Comp ID Examined Edition/I 996 Addenda Exmied Appendix VIII B-F B5.70 1007190 NSE-4R 2009 X
1006990 NSE-3R 2009 X
B-J B9.11 1007000 PL-FW-III-R 2009 X
1007200 PL-FW-X-R 2009 X
1012000 PL-FW-XIII 2008 (1) 1012100 PL-FW-VI 2005/2006 X
1013500 PL-FW-XV 2005 (1) 1013600 PL-FW-VIII 2008 X
1014500 D
2009 X
1028900 A
2009 X
1029400 B
2008 X
1030300 CSW-5 2009 X
1030400 A
2009 X
1030700 C
2008 X
1034300 H
2003/2006 X
1035900 H
2002 X
1036200 J
2002 X
B-J B9.31 1011000 PL-FW-II 2005 X
B-M-1 B12.40 1059200 V-720-1 (Body 2009 X
Weld)
V-720-2 (Body 2009 X
1059205 Weld)
(1) ISI weld configuration consists of CSS to CSS material.
Page 1 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request ISI-02 Question No. 2 ASME Code Categor B-F, Pressure Retaining Dissimilar Metal Welds in Vessel Nozzles, Item No. B5. 70 Nozzle to Safe End Welds, NSE-3R (Inleo and NSE-4R (Outlet)
Question No. 2a
- a.
In regards to these welds, ISI-02 states "the "B" steam generator inlet/outlet nozzle to safe-end welds are considered as dissimilar metal welds consisting of a stainless steel clad-carbon steel nozzle with Inconel Alloy 690 weld material to a stainless steel safe end." Inconel 690 is a designation for base material. Please clarify the weld material type.
Response
- a.
In accordance with Ginna Station 3rd Interval ISI Program approved Relief Request Number 27, weld filler metals used were in accordance with Code Case 2142 and 2143. Currently, the weld filler metal is designated as alloy 52 (AWS A5.14, ERNiCrFe-7) and alloy 152 (AWS A5.1 1, ENiCrFe-7) as listed in ASME Section IX, Article 4 under F-43 filler metal.
Question No. 2b
- b.
Please provide afigure and coverage calculations for Component ID NSE-4R (100 7190) and coverage calculations for Component ID NSE-3R (1006990). Please ensure that figures provided for both components clearly depict all wave modalities and insonification angles used (please note that the figure and caption should match) and examination limitations encountered Please keep in mind that the figures are transmitted as black and white, so that different styles of lines should be used to distinguish between axial and circ scans or, if necessary, provide afigure for each of the scan directions.
Response
b, The Ginna ISI Vendor provided additional coverage calculations to support the examination record coverage final figures as provided. See Attachment # 1.
Question No. 2c
- c.
It is the NRC staff's understanding that the Performance Demonstration Initiative (PDI) program requires two angles in order to claim ASME Code coverage for a Supplement 10, single side exam.
Please clarify whether your Code coverage calculations were made using two angles. Did a single angle provide greater coverage? If so, how much?
Response
c, Yes, the site examination record indicates a combined Code coverage % using multiple scan angles by the ISI Vendor coverage calculations. See Attachment # 1.
Did a single angle provide greater coverage? Yes. The single angle providing greater coverage was the 600 RL probe that was approximately 96% coverage from one-side of the weld.
Page 2 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request IS1-02 and ISI-03 Relief Reauest ISI-02 Ouestion No. 2d d
The PDI qualification program requires that for DM welds, the weld crown condition must be ground flush or machined to allow for adequate scanning on top of the weld and butter material.
Why wasn't the Inconel weld ground flush to allow for scanning on top of the weld and butter material?
Response
- d. Prior to the 2009 outage, an engineering evaluation was performed to calculate the component required minimum thickness values for this complex dissimilar metal (DM) weld configuration. An engineering change package (ECP) was generated based on the Replacement Steam Generator project installed weld configuration. The evaluation outputs determined that the "As Found" component thicknesses of the S/G nozzle and safe-end were very near the calculated T-min values.
During the evaluation phase, the original manufacturer was consulted for original design basis of these complex weld configurations. The manufacturer designed and fabricated the Replacement S/G DM weld to safe-end configuration prior to being shipped to site. The replacement S/G's were fitted into place with the existing RCS elbows (Cast SS), using the DM final design configuration and existing ID/OD fit-up offsets. The site made the decision not to alter the existing elbows other than to machine the outer surface for adequate fit-up requirements. The DM weld SS safe-end component was reduced in its length (very short) to provide the required fit-up dimensions. This fit-up created the narrow groove tie-in weld from the safe-end to existing CSS elbows.
Just prior to performing the weld crown reduction (WCR) preparation of the primary nozzle DM welds, engineers preparing the ECP determined that the welds could not be ground flush per the procedural requirements of PDI-UT-10 without potentially violating the required T-min values.
Background factors:
Just prior to the outage while engineering evaluation activities were occurring, the site formulated an Issue Response Team (IRT). The IRT had an action to select an experienced vendor to perform the DM weld crown removal (WCR) process. Three vendors were selected and assessed; the best fit was a vendor with an automated sanding process. The WCR vendor mobilized to site and started the set-up process by performing a hands-on walk-down in containment for actual field conditions. As the weld configuration is extremely complex (a 150 OD taper on the primary CS nozzle to a 301 angle machined face of the DM welds with a very short safe-end interface to a machined tie-in weld of the RCS CSS elbow), it made mounting the sanding fixture difficult. Mounting could only be 1) to the tapered surface at one end or 2) encroaching on the elbow at the other end. Also, it was discovered in the field that there were some existing external obstructions adjacent to the area to the DM weld configuration that interfered with the WCR sanding equipment, preventing it from going around the entire circumference of the welds during the proposed automated sanding process.
Based on these facts, the site started a hand grinding process with a different vendor on a spare piece of the site-specific mockup. The site realized that this process had high risks involved with hand grinding (uncontrolled process) on a complex configuration and that this grinding process was very time-consuming (inconel weld material was very difficult to hand grind) based on time trials, requiring many physical man-hours including RP & NDE oversight, that would incur high accumulated dose. The actual field dose rates adjacent to the S/G primary nozzle welds was approximately 40 Mremn/Hr. Actual field trials of hand grinding resulted in time estimates at 100 Page 3 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request IS1-02 man-hours x 40 Mrem/hr = 4 Rem dose, in addition to RP and NDE oversight equaling 48 man-hours x 40 Mrem/Hr = 2 REM dose, for a total of approximately 6 REM to personnel.
Based on the dose considerations together with the concerns for violating piping T-min requirements, it was decided to keep the existing weld configurations intact.
Question No. 2e
- e.
The staff believes that it would be possible to obtain greater coverage through various options including the use ofphased array ultrasonic inspection (PA UT) employing site-specific mockups, if necessary. As such, please address why PA UT was not employed in the 4th interval. What will be done for future examinations to maximize ASME Code coverage?
Response
- e.
The site consulted EPRI NDE Center PDA staff to gain some insight into PAUT as compared to conventional manual UT on the site's complex configuration. EPRI's opinion was PAUT would not provide any additional coverage but would be beneficial for flaw depth sizing if flaws were detected.
The site compared conventional manual UT to phased array techniques during 2008 and 2009. The site elected to go with the qualified conventional UT examinations. This decision was made prior to the fabrication of a site specific mockup for the required technical justification and performance demonstration.
References:
"EPRI - Review of Ginna Nuclear Power Plant Dissimilar Metal Weld Walk-down Information" document; IR-2009-359.
"EPRI - Technical Justification for the Acceptance of Ultrasonic Examination Demonstration Results on Ginna Steam Generator Nozzle Dissimilar Metal Weld Configurations with PDI-UT-10, Revision C" document; IR-2009-3 81.
Question No. 2f f
Please address how this weld was examined during pre-service inspection (PSI) and the Code coverage achieved.
Response
- f.
Pre-Service examinations on welds NSE-3R and NSE-4R were performed in 1996 in accordance with ASME Section XI Code, 1986 Edition, No Addenda. UT and PT examinations were performed and Code coverage obtained was > 90%. The Appendix VIII requirements did not exist at this time.
Question No. 3 ASME Code Category B-J, Pressure Retaining Welds in Piping, Item No. B9.11 Circumferential Pipe Welds PL-FW-111-R and PL-FW-X-R Page 4 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request IS1-02 Ouestion No. 3a
- a.
Please provide coverage calculations for Component IDs PL-FW-III-R (1007000) PL-FW-X-R (1007200). Please ensure that figures clearly depict all wave modalities and insonification angles used (please note that the figure and caption should match) and examination limitations encountered Please keep in mind that the figures are transmitted as black and white, so that different styles of lines should be used to distinguish between axial and circ scans or, if necessary, provide afigure for each of the scan directions.
Response
- a.
During the preparation and fabrication of the required DM weld site-specific mockup, a pre-outage technical error and lack of reviews missed the fact that the narrow groove tie-in weld adjacent to the DM weld was also needed for performance demonstration. Once the ISI examination started, it was discovered that SS safe-end had the following factors: wall thickness greater than what was qualified in PDI-UT-2 procedure; on a taper surface; and scanning thru the adjacent DM weld.
These facts mean that the site cannot claim any code coverage; therefore no code coverage 0% was credited. A total of 10% best effort coverage (450 shear wave on top of safe-end and 600 RL thru the adjacent DM weld) was obtained as documented in Reference 1. Based on CSS material (RCS Elbow) this configuration would be a single-sided examination (50%), and scanning thru adjacent dissimilar metal weld on a tapered surface makes this examination very limited.
Ouestion No. 3b
- b.
The staff acknowledges that these are difficult examinations; however, the staff believes that it would be possible to obtain greater coverage through various options including the use ofphased array ultrasonic inspection (PA UT) employing site-syecific mockups, if necessary. As such, please address why PA UT was not employed in the 4t interval. What will be done for future examinations to maximize ASMEf Code coverage?
Response
- b.
The site consulted EPRI NDE Center PDA staff to gain some insight into PAUT as compared to conventional manual UT on the site's complex configuration. EPRI's opinion was PAUT would not provide any additional coverage due to tapered surface and limited scanning thru an adjacent DM weld but would be beneficial for flaw depth sizing if flaws were detected. The site compared conventional manual UT to phased array techniques during the 2008 and 2009 timeframe. The site elected to go with the qualified conventional UT examinations.
For the future, the site should modify the existing site-specific mockup to include the narrow groove weld configuration with flaws that will be adjacent to the DM weld as in the field. At this time, it will be possible for a qualified ISI vendor to demonstrate a qualified UT technique such as PAUT on this component for flaw detection and applicable code coverage.
Ouestion No. 3c
- c.
Please address how this weld was examined during PSI and the Code coverage achieved Page 5 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Reauest IS1-02
Response
- c.
Pre-Service examinations on welds PL-FW-III-R and PL-FW-X-R were performed in 1996 in accordance with ASME Section XI Code, 1986 Edition, No Addenda. PT PSI examinations of both welds from the inside (ID) and outside (OD) surfaces were performed and 100% coverage obtained.
RT PSI examinations were performed and 100% coverage obtained.
Question No. 4 ASME Code Category B-J. Pressure Retaining Welds in Piping, Item No. B9. 11 Circumferential Pipe Welds PL-FW-XIII, PL-FW-VI, PL-FW-XV PL-FW-VIII, D. A. B. CSW-5. A. C.H, H and J Question No. 4a
- a.
For all the welds listed above, please ensure that coverage calculations are provided, and that figures clearly depict all wave modalities and insonification angles used (please note that the figure and caption should match).
Response
- a.
In accordance with the qualified PDI procedure, it states that it is not qualified for:
Detection or length sizing of circumferentially oriented flaws when only single side access is available and the flaw is located on the far side of the weld, however guidance is provided to perform a best effort examination of the far side examination volume. The techniques identified in this procedure have been demonstrated to be representative of "best effort" technology for single side detection of far side flaws parallel to the weld. Therefore, 50% "Code coverage" has been claimed for the near side volume and 50% (or whatever additional coverage applies) "best effort coverage" for the far side portion of the examination volume."
Weld # PL-FW-XIII - Elbow to Pump, 48% Code Coverage 450 & 600 shear-wave and 600 RL on elbow side. Far side was examined best effort with 600 RL.
Weld # PL-FW-VI - Pump to Pipe, 50% Code Coverage 450 shear-wave and 600 RL on pipe side. Far side was examined best effort with 600 RL.
Weld # PL-FW-XV - Elbow to Pump, 40.5% Code Coverage SLIC20 on elbow side. Far side was examined best effort with SLIC20. See Attachment 2a and 2b.
Weld # PL-FW-VIII - Pump to Pipe, 50% Code Coverage 450 & 600 shear-wave and 600 RL on pipe side. Far side was examined best effort with 600 RL.
Weld # D - Pipe to Nozzle, 74% Code Coverage based on 100% CW/CCW scans using 450 shear wave and US axial scan minus welded ID tag 0% + 96% + 100% + 100% / 4= 74%. Far side was examined best effort with 600 RL.
Weld # A - Valve to Pipe, 50% Code Coverage 450 & 600 shear-wave on pipe side. Far side was examined best effort with 600 RL.
Weld # B - Pipe to Valve, 49.5 % Code Coverage 450 & 600 shear wave on pipe side. ID tag in area of interest -0.5% far side was examined best effort with 60' RL.
Weld # CSW Tee to Pipe, 50% Code Coverage 450 shear wave. Far side was examined best effort with 600 RL.
Page 6 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISl-02 and ISI-03 Relief Request ISI-02 Weld # A -Nozzle to Pipe, 74% Code Coverage based on 100% CW/CCW scans using 450 shear wave and DS axial scan minus welded ID tag 0% + 96% + 100% + 100% / 4= 74%. Far side was examined best effort with 600 RL.
Weld # C - Valve to Pipe, 49.5% Code Coverage 450 & 60' shear-wave on pipe side, welded id tag = 0.5%. Far side was examined best effort with 600 RL.
Weld # H - Pipe to Valve (867A) 48.75% Code Coverage 450 & 600 shear-wave, welded id tag = 1.2%. Far side was examined best effort with 600 RL.
Weld # H - Pipe to Valve (867B) 50% Code Coverage 60" shear-wave. No best effort scan performed on far side with RL transducer.
Weld # J - Valve (852B) to Pipe 50% Code Coverage 450 & 600 shear-wave. No best effort scan performed on far side with RL transducer.
Question No. 4b
- b.
For Component ID PL-FW-XV (1013500), the use of insonification angles of 20 L/30°L is atypical.
Was the procedure qualified to the PDI? Were these angles used for both the axial and circumferential scans? Why weren 't any shear wave exams performed? Lastly, the sketch of this component for the axial exams indicates that there was coverage on the pump side, even though the pump is cast. Please provide clarification.
Response
- b.
This ISI weld (PL-FW-XV) configuration is a Cast Stainless Steel elbow to Cast Stainless Steel pump casing, therefore the procedure used was not qualified to PDI. The procedure used manual ultrasonic with best available technology, where grain structure contributes to considerable sound attenuation and diffusion. The ISI vendor provided a search unit (SLIC20) to the site that produced a better signal to noise response then the 450 shear wave used previously (1995). The ISI vendor demonstrated on the site's CSS calibration block that the 20°L/300 L search unit could see the ID notch at the component thickness (2.4") as compared to the shear wave. Based on these facts, the weld was examined with these transducer angles. Coverage plot and transducer focus plot information are provided in Attachment 2a and 2b.
Question No. 4c
- c.
For Component ID H (1035900), please explain why a 450 shear wave exam was not performed Also, the PDI Program requires, for single sided exams of components greater than 0. 5" thick, the use of refracted longitudinal waves to provide adequate coverage on the far side. Though this is not a PDI qualified exam, it is considered best effort. Please address why a RL exam was not performed on this weld.
Response
- c.
In the 2002 Refueling outage, the site qualified examiner and site level III misinterpreted the qualified generic procedure which states, "The primary angle shall be lowest angle that provides coverage of the required examination volume from each side of the weld." The examiner used a 600 shear wave for the pipe side of the weld and for the CW & CCW scans. During the review process, the site UT Level III reviewer missed that the qualified PDI UT examiner did not perform a best effort examination on the far side of the weld using a RL transducer.
Page 7 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request ISI-02 Question No. 4d d
For Component J (1036200), as asked in "c" above, please address why a longitudinal wave exam was not performed on this weld per the PDI program.
Response
- d.
During the review process after the 2002 refueling outage, the site UT Level II reviewer missed that the qualified PDI UT examiner did not perform a best effort examination on the far side of the weld using a RL transducer.
Question No. 4e
- e.
On page 7 of 21, the text reads, "There were no recordable indications found during the inspection of these welds." Please clarify whether this statement refers to only the UT exams performed or does it also include the surface exams performed on welds PL-FW-VI, PL-FW-XV, H (1035900) and J?
Response
- e.
The four welds, PL-FW-VI, PL-FW-XV, H (1035900) and J had UT and PT examinations performed and all four welds had no recordable indications for UT and PT.
Question No. 5 ASME Code Categor B-J. Pressure Retaining Welds in Piping. Item No. B9.31 Branch Weld, PL-FW-II Question No. 5a
- a.
Please ensure that the figure clearly depicts all wave modalities and insonification angles used.
Response
- a.
For weld # PL-FW-II; 45' & 600 shear wave angles were utilized on branch side of the weld configuration during examination; a 60°RL angle was used for near and far side best effort coverage.
Base metal examination using a 0' was also performed.
Question No. 5b
- b.
Please explain how 75% coverage was achieved when it was stated in the text that this was a single-sided examination only.
Response
- b.
This examination coverage was mistakenly submitted as 75% coverage. The actual coverage equals 50% Code coverage based on being single-sided exam criteria. This report has been updated to reflect the actual coverage.
Page 8 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request ISI-02 Question No. 5c
- c.
Were any recordable indications found during either the UT or surface exams of this weld?
Response
- c.
Weld PL-FW-II had both UT and PT examinations performed. No recordable indications were identified.
Question No. 6 ASME Code Category B-M-J, Pressure Retaining Welds in Valve Bodies, Item No. B12.40 Valve Body Welds, V-720-1 and V-720-2 Question No. 6a
- a.
The figures associated with the welds listed above do not adequately depict the limitation on the valve side. Please indicate the limitations.
Response
- a.
This ISI component consists of a valve configuration with valve body extension welds. These two welds are in close proximity to valve body vertical walls. When placing the transducer/wedge up against this vertical interface, the probe insonification angle is just beyond the code coverage box from the opposite scan direction creating the limitations.
Page 9 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request ISI-03 Question No. 1 ASME Code Category C-F-I, Pressure Retaining Welds in Austenitic Stainless Steel or High Alloy Piping. Item No. C5.21 Circumferential Pipe Welds 18, 6. 14, 15, 8. and 56 Ouestion No. la
- a.
On page 3 of 11, the text states that "the examination coverage was based on the aggregate from manual scans of shear and longitudinal wave scans perpendicular and parallel to the weld in one axial direction and two circumferential directions and 0-degree longitudinal wave." In light offact that scans were performed in one axial and two circ directions, it would appear that up to 75%
coverage would have been possible. Therefore, please clarify the coverage calculations for all of these welds.
Response
- a.
In accordance with the qualified PDI procedure, it states that it is not qualified for:
Detection or length sizing of circumferentially oriented flaws when only single side access is available and the flaw is located on the far side of the weld, however guidance is provided to perform a best effort examination of the far side examination volume. The techniques identified in this procedure have been demonstrated to be representative of "best effort" technology for single side detection of far side flaws parallel to the weld. Therefore, 50% "Code coverage" has been claimed for the near side volume and 50% (or whatever additional coverage applies) "best effort coverage" for the far side portion of the examination volume."
Weld # 18 - Pipe to Tee configuration, 82.5 % Code Coverage, limitation due to Tee crotch areas, 600 shear wave was used for CW/CCW scan directions, the 700 shear wave was used for US/DS scan directions. See Attachment # 3.
Weld # 6 - Pipe to Valve (870A) 50% Code Coverage using a 450 shear-wave on pipe side.
Far side was examined best effort with 700 shear wave.
Weld # 14 - Valve to Pipe (871B) 50% Code Coverage using a 450 & 520 shear-wave on pipe side. Far side was examined best effort with 700 shear wave.
Weld # 15 - Pipe to Valve (870B) 50% Code Coverage using a 450 & 520 shear-wave on pipe side. Far side was examined best effort with 700 shear wave.
Weld # 8 - Valve to Pipe (888B) 50% Code Coverage using a 450 & 600 shear-wave on pipe side. Far side was examined best effort with 700 shear wave.
Weld # 56 - Flange to Pipe (FE-125) 50% Code Coverage using a 450 & 520 shear-wave on pipe side. Far side was examined best effort with 700 shear wave.
Page 10 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request IS1-03 Question No. lb
- b.
Was the 0-degree scan done for all of the welds?
Response
- b.
The 0-degree scan was performed on the following welds:
" Weld # 18 - Pipe to Tee-No, however, it was performed in the previous exam (1997)
" Weld # 6 - Pipe to Valve (870A) -Yes
- Weld # 14 - Valve to Pipe (87 1B) -Yes
" Weld # 15 - Pipe to Valve (870B) -Yes
" Weld # 8 - Valve to Pipe (888B) -Yes
" Weld # 56 - Flange to Pipe (FE-125) -Yes Question No. le
- c.
Please ensure that the figures clearly depict all wave modalities and insonification angles used, and the limitations encountered
Response
- c.
The figures, (provided in Reference 1), depict the requested information, with the associated limitations listed below.
" Weld # 18 - Pipe to Tee - limitation was tee crotch areas (2)
- Weld # 6 - Pipe to Valve (870A) - limitation due to cast stainless steel valve body side;
- Weld # 14 - Valve to Pipe (87 1B) - limitation due to cast stainless steel valve body side;
- Weld # 15 - Pipe to Valve (870B) - limitation due to cast stainless steel valve body side;
" Weld # 8 - Valve to Pipe (888B) - limitation due to cast stainless steel valve body side;
" Weld # 56 - Flange to Pipe (FE-125) - limitation was on flange side.
Question No. ld d
Provide a replacement figure for Component ID 18 as the figure provided in ISI-03 is too blurred to read.
Response
- d.
See Attachment # 3 for an improved image of component ID 18 weld.
Question No. le
- e.
On page 3 of 11, the text reads, "There were no recordable indications found during the inspection of these welds. " Please clarify whether this statement refers to only the UT exams performed or does it also include the surface exams performed on welds 14, 15, 8, and 56.
Page 11 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request ISI-03
Response
- e.
The four welds, 14, 15, 8 and 56 had UT and PT examinations performed. All four identified welds had no recordable indications as a result of either of the examinations.
Question No. 2 ASME Code Categoa C-F-2, Pressure Retaining Welds in Carbon or Low Alloy Piping, Item No. C5.51 Circumferential Pipe Welds G2-BC-2-A and L2-BC-2-A Question No. 2a
- a.
Please clarify/provide the coverage calculations for these welds.
Response
- a.
Weld # G2-BC-2-A and Weld # L2-BC-2-A:
- The Weld # G2-BC-2-A examination record had a total of four directions (CW, CCW, US, DS) for scan coverage. Two examination angles were used to examine the weld volume, 450 & 700.
Based on the component configuration, there is a 3/4" diameter Weld-O-Let in the area of interest. The component circumferential measurement equal 21" in length, the total scan was 18.75". 18.75/21 = 89.3%. In the axial scan direction, there was a heat trace wire in area of interest. This heat trace wire limits the total area from being scanned. A total of 80% coverage was claimed for these axial direction scans. Total coverage for the four directions equals 89.3% +
89.3% + 80% + 80%= 338.6 / 4 = 84.65%.
- The Weld # L2-BC-2-A examination record had a total of four directions (CW, CCW, US, DS) for scan coverage. Two examination angles were used to examine the weld volume, 450 & 600.
Based on the component configuration, there is a 3" diameter Sweep-O-Let in the area of interest.
The component circumferential measurement equals 21.5" in length; the total scan was 18.5".
18.5/21.5 = 86%.
Question No. 2b
- b.
Please ensure that the figures clearly depict all wave modalities and insonification angles used, and the limitations encountered
Response
- b.
The figures depict the requested information, with the associated limitations listed below.
" Weld # G2-BC-2-A - limitation encountered was 3/4" diameter Weld-O-Let fitting and a heat-trace wire causing interference.
- Weld # L2-BC-2-A - limitation encountered was 3" diameter Sweep-O-Let fitting in the area of interest.
Page 12 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Relief Request ISI-03 Ouestion No. 2c
- c.
On page 4 of 11, the text reads, "There were no recordable indications found during the inspection of these welds. " Please clarify whether this statement refers to only the UT exams performed or does it also include the surface exams performed on weld L2-BC-2-A.
Response
- c.
Clarification of requested information for weld # L2-BC-2-A:
- Weld # L2-BC-2-A had UT and MT examinations performed. This weld had no recordable indications for both the UT and MT examinations.
Page 13 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request IS1-02 and IS1-03 Coverage calculations and cross sections showing UT coverage/limitations for NSE-3R & NSE-4R COVERAGE DEITKMU4ATIO1 In th covemar calculatioin pmvidcd for components NWE-3L and lNSE 41k, the a*ea roforred to on the ultasonic coverage and limitation shcee were arrived at by using teh Microsoft Visio drawing program.
This prngmm allows the user to outline ft awn in rpiesrinn and prevides the cal-ulAted area value. Sn all the part geometric limitations wern consistent for 360 degrees, the area was used to generat* the petent of coveram For component NSE 3P and NSE 4X, the 45 degree Refracted Longiudinal (PJL) wave axi tnrasnc r
obtained 2.34 Square Inches of the cod zequired am of 4.51 Square Inches from a satrue droct~or Resulting in 52% coverage of the code required area (volume). The limitation was caused by componen geometry.
For the 60 dagree (RL) wave. examination of NEE 3R and WSE 4R. 4.32 squae inches of om-*rp was obtained of the 4. 1 square in4hes of code requir*d area (volume). Resulting in 96% coverg*. The limition was caus*d by component gspn
- y The 45 degree clrcumlbremial examinations, which were conducted fo the saf end sids of the weld, were limited by part geometry and surface condition-For NSE 3R 2.62 square inches or 58% of the code required area (volume) was scanned, This number was reduced 50% by the examiner due to the suxtee condition of the cunponeat and an inability to mainain adequate contact during tft examination. For NSE 4R 2.85 square inches or 64% of the code required area (volume) was scanned. Ti number was reugod 451% by te examiner due to the surface coditon of the comlponnt aud au ihability to umaitain adequate contact during the examination. As indicated on tWe ultrasonic coverage and limitation shea.
The 45 degree shear axial and circumferential exams were conducted in both directioms over all accessible areas, The coverage obtained to equal to the 45 degree Pt examinatL_
While these examinations were pesrned.d they are aot included in the covera calculadons COVERAGE CALCULATIONS IJ the report GINHA-3R-01 and GJNNA,4R-0l. coverage calcuiations were made by taking the percent of oerage of the 45 degree RL axial exam, the 60 degree RIL axial exam, the 45 degree RL circumferential cock--wie eanm, and thet 4s degree RL couatercleokwise RI exam and dviding by Ow nouneofr emainations (4). This calculation pmovides a composite coverage for all &wr examinations. At tbe ti1e ofthc camiuntions. the guidance i"r determining covtcraf requirments -es vaSpa in th* PD1 rrT-lO procedure and this method for detennining coverage was adopted-When detimning covearage ung the area that two angles cover, the coverage of the 45 degree RPL defines the area where two angle both provide covwerage, In ti instance the coverae of the 45 RL and the 60 degree RL are 2.34 square inches or 52% ooer-age and there is no change in the coverage of the chtumlrential examinations.
MER=
The percentage calculatim for NSE 3R would be 52% tar the 45 RL, 52% for the 60 RL 29% for the circuinvuiat clncwie rcam inon a"d 29% for the circum*fmntial Ccuntr clockwis ecxamiiawion.
This results in a coverage of 40.5%
52 + 52 + 29 + 2914 = 40.5% code coverage Page 14 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 COVMRGE CALCULATIONS (CONT.)
NSE-*t The pucentage calkulation for NSE 4R would be 52% for the 45 RL, 52% for the 60.1RL, 32% for the ircuafertial clockwis examimtion, and 32% for the circumferential comuer clockwise examivatio This relts in a coverage of 42%
52 +52 +32 + 3214 - 42% co& coverage When looking at total coverage of each examination repcivey, the calculations ame as follows NSE-3R For NSE 31R, ft 60 IRL coverage was 96%, the 45 RL ciomfernlal clockwise examination was 29%..
and the circumferential 45 RL counter lockwimse examination was 29%. This results in a coverage of just the 6ORL and the two 45 RL cite scans is 51 3%
60 RL coverage w/dcrnferemtial scans 96+29+29/3w 51,3% coverage Fox NSE 3R, the 45 RL axial coverage was 52%, the 4S RL ckim ential clockwise examination was 29%. and the circumferential 45 RL counter clockwise examination was 29%/ This results in a coverage djust the 45RL and the two 45 RL circ scans is 36.6%/o 45 RL coverage w/cgrcumfereutial scans 52 + 29 + 29 13 = 36.6% coverage NSE 4R For NSE 4X, the 60 RL coveraW was 96%, the 45 RL circumfrta clockwise exmuinnion was 32%.
and the circumferential 45 RL counter clockwise exanation was 32%. This zesulis in a coveane of 53.3%
60 RL roverage w/ciruuferntiai scans 96 + 32 + 32 / 3 = 53.3% covere For the 45 RL axial coverage was 52%. the 45 RL circunferentia dockwse examination was 32%. and the circxuerential 45 RL counter clockwise examination was 32% This results in a coverage of 39.6%
45 RL coverage w/ circumferential scans 52 + 32 + 32 / 3 = 38.6% coverage Page 15 of 20
LLTRASONIC COVERAGE AND LIMITATION SHEET
[Repoary NJo.
GiN0"vLO Customer Information Compintoent In~formTationl
- ulililtý- k;umsIC-h1;"r!
ISiet: -'Znn.;
uni:
Sse Weld ID: -B SeaM Generaioi INSIE*3R Covweraua Data Shapet ND.: COV "t-C Wemc!
nft Co00e Atca o-2'V :AU 5
AXI3 Code CoveragWs Dbtalfled Cirt Code Coverage's Oblaintcl Covorage Caikulationr, 45*' RL 2.1 in, (5256)
Go-RL 32,W~ cmv')
- nR.=
' j2"..
RL ;omposite Coverage s51.6%
See t~ots Spe Notes 19 f,9 f-SCAM
-VSee*f./
~ ~'5 Y5
.iSIM~d
/
- -f
/
I
/
I-a Qt
/
I,
/
0 0
0 S
0 0
.- 0 0
F-I a.
W.
i-tow vrel~ I
/
/
/
/,
t
/
/
/
1'
~
I, Notes. 10'.'erage mtormiafictgven is 1je bes. est~natcio due to cceponenl qieoaijy:
AetmeveV C-overage ot Ih aciunI rernhliaeexanhinai~ons asditlusmclrae was tedt.ced by 50%. dLe 10 bss ol cciacl and resiricled aioday mcperforn skewed scals 9s r-.qxredjby Tuchný.i Jusificalon IR-flt00--301. as c, reseli of surface conifftior.
Above diurt.ronnet 10 I
AREVA NdP Inc.. an ARE VA and Sieeners comoanvn.
anne 7 of R
utility: Constellation site7: G1ka'I Unit, I System I Weld ID: TB Steam Generallor i NSE-4R coverage Data Sheet No.: COV.4R-O1 Weld info Axib1 Coft Covrerage's Obtained Clic Code Covesage' Obtarrnl Covarage catculations Coork Area of 0M Mplu =4 51 in d53 RL a2.34 ir 152%)
45'R AL -$
1.A e (3T.
RI Compiip 0 ts CoveiaW =53 So ~SSee Notq oes
~~A6.'f' SCWk)~
/
/
/
/a
/
0q 0
O==
M PQ
/
/
0 Ca X
0 0
.0 0
0M 02 IN X.
CO.
CL 0D W
Cast SiainEene we)r N
,/
/
4.
I.
/
/:
/
/
'/
I~'
/~'
k I,
7 KNc'e-s. Coverage inlo-malion giyen is the bett esirmalion due to comnpowen geometry.
IAchie~ed cover age ri flit! arcrnfemrteient exami~nalios. as ilustraked. was reduced by 4.5% due to loss of coniact anid resh ii,:d abidi v In pwsform 'KieWee1 scans.
'sreured by iTvchniml Jusl:iicatca) IR-2(104iW8. as a resutl ni surlace -ondillor.
a eurdb Abvve, ilusitetlo0f is Nol Th Scaile flL
.r IVf.,j ga, 1 91 MM compatnV Page 7 of
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 a Examination Coverage for RC-PL-FW-XV Dump Pu rn p Etbow E Ubcow (Uir'ci Ex(Xfl
/Axi~a E~xorm Examination Coverage:
Axial Coverage Down = 62%
Axial Coverage Up
= 0%
Parallel Coverage CW = 50%
Parallel Coverage CCW = 50%
Average = 40.5%
Page 18 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 b SlUC Module Beam Traces Showing Focal Depth of SLIC 20 for Responding to Needed Depth SLIC MODULE BEAM TRACES SLIC 30 SLIC 40 SLIC 50 SLIC 35 10 65 5070 40 6040 50 L
L L L S
LLL 0.197 0.T.787 SLIC 25 SLIC 20 SLIC 15 SLIC 45 Page 19 of 20
ENCLOSURE Response to Request for Additional Information Regarding Relief Request ISI-02 and ISI-03 Weld Cross-Sectional Views Item C5.21 Component ID: 18 (1162770)
Limitation due to tee curvature Wave Modality and Insonification angles (60"s and 70*s)
(Axial and Circ Directions) were used for scanning, where accessible.
FP PC q9
'Z70 Tryp.CAL-T-F6 le 4.
,,J n
.10 0 100C 100 0
r4ed1rd "'Jýfh ý', ý. S' 000'Mrd OP-SOP-Lictic'Al -'- ?
(o 7C) 0 0
Irl "i
0,,,) Lc-,Oký Aý, 001-;t4 Page 20 of 20