MONTHYEARML1027307792010-09-30030 September 2010 CLI-10-27 Memorandum and Order Denying Interlocutory Appeals, Reverse the Board Order, and Terminate Adjudicatory Proceeding Project stage: Request ML1107408522011-03-14014 March 2011 Declaration of Karen Hadden on Behalf of Seed Coalition Project stage: Other ML1107408502011-03-14014 March 2011 Declaration of Susan Dancer on Behalf of Seed Coalition Project stage: Other ML1107408482011-03-14014 March 2011 Petition for Leave to Intervene and Request for Hearing of Seed Coalition and Susan Dancer Project stage: Request ML1109705442011-04-0707 April 2011 STP Nuclear Operating Companys Answer Opposing Request for Hearing and Petition for Leave to Intervene Project stage: Request ML1109706592011-04-0707 April 2011 NRC Staffs Answer to Petition for Leave to Intervene and Request for Hearing of Seed Coalition and Susan Dancer Project stage: Request ML1112800022011-05-0808 May 2011 Petitioners Proposed Amended Petition for Leave to Intervene & Request for Hearing of Seed Coalition & Susan Dancer Project stage: Request ML1112800032011-05-0808 May 2011 Intervenors Request for Oral Argument on Contentions Raised on Relicensing Project stage: Request ML1114307992011-05-23023 May 2011 Order (Scheduling Oral Argument) Project stage: Request ML11161A1432011-06-0202 June 2011 License Amendment Request for Approval of a Revision to the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Request ML1115303932011-06-0202 June 2011 NRC Staff Answer to Proposed Amended Petition for Leave to Intervene and Request for Hearing of Seed Coalition and Susan Dancer Project stage: Request ML1120101502011-07-22022 July 2011 License Amendment Request to Approve Revision to Fire Protection Program Related to Alternate Shutdown Capability - Unacceptable for Review with Opportunity to Supplement Project stage: Other NOC-AE-11002703, Supplement to the License Amendment Request for Approval of a Revision to the South Texas Fire Protection Program Related to the Alternative Shutdown Capability2011-08-0101 August 2011 Supplement to the License Amendment Request for Approval of a Revision to the South Texas Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Supplement ML11221A2302011-08-0101 August 2011 Supplement to the License Amendment Request for Approval of a Revision to the South Texas Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Supplement ML1121404492011-08-0909 August 2011 License Amendment Request to Approve Revision to Fire Protection Program Related to Alternate Shutdown Capability - Acceptable for Review Following Supplement Project stage: Other ML1204001382012-02-0808 February 2012 Email, Request for Additional Information, License Amendment Request to Approve Revision to Fire Protection Program in Fire Hazards Analysis Report Related to Alternate Shutdown Capability Project stage: RAI ML1204001462012-02-0808 February 2012 Request for Additional Information, License Amendment Request to Approve Revision to Fire Protection Program in Fire Hazards Analysis Report Related to Alternate Shutdown Capability Project stage: RAI ML1204701642012-02-16016 February 2012 Request for Additional Information Email, Round 2, License Amendment Request to Approve Revision to Fire Protection Program in Fire Hazards Analysis Report Related to Alternate Shutdown Capability Project stage: RAI ML1204701612012-02-16016 February 2012 Email, Request for Additional Information, Round 2, License Amendment Request to Approve Revision to Fire Protection Program in Fire Hazards Analysis Report Related to Alternate Shutdown Capability Project stage: RAI ML12079A0382012-03-0808 March 2012 Response to Request for Additional Information Regarding License Amendment Request for Revision to the Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Response to RAI NOC-AE-12002801, Response to Request for Additional Information Regarding License Amendment Request for Revision to the Fire Protection Program Related to the Alternative Shutdown Capability2012-03-0808 March 2012 Response to Request for Additional Information Regarding License Amendment Request for Revision to the Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Response to RAI ML12101A2232012-04-0303 April 2012 Response to Request for Additional Information, 01.1, Regarding to the License Amendment Request to Revise the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Response to RAI NOC-AE-12002827, Response to Request for Additional Information, 01.1, Regarding to the License Amendment Request to Revise the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability2012-04-0303 April 2012 Response to Request for Additional Information, 01.1, Regarding to the License Amendment Request to Revise the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Response to RAI NOC-AE-12002838, Response to Request for Additional Information, RAI-01.1, Regarding the License Amendment Request to Revise the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability2012-05-0303 May 2012 Response to Request for Additional Information, RAI-01.1, Regarding the License Amendment Request to Revise the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Response to RAI ML12135A1822012-05-0303 May 2012 Response to Request for Additional Information, RAI-01.1, Regarding the License Amendment Request to Revise the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Response to RAI ML12213A0592012-07-31031 July 2012 Notice of Appearance of Lloyd B. Subin on Behalf of the U.S. Nuclear Regulatory Commission in the Matter of South Texas, Units 1 and 2 Project stage: Request NOC-AE-12002892, Withdrawal of Proposed License Amendment Request to Revise the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability2012-07-31031 July 2012 Withdrawal of Proposed License Amendment Request to Revise the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Withdrawal ML12220A5092012-07-31031 July 2012 Withdrawal of Proposed License Amendment Request to Revise the South Texas Project Fire Protection Program Related to the Alternative Shutdown Capability Project stage: Withdrawal ML12222A0262012-08-14014 August 2012 FRN - Withdrawal of License Amendment Request to Approve Revision to Fire Protection Program in Fire Hazards Analysis Report Related to Alternate Shutdown Capability Project stage: Withdrawal ML12222A0232012-08-14014 August 2012 Letter, Withdrawal of License Amendment Request to Approve Revision to Fire Protection Program in Fire Hazards Analysis Report Related to Alternate Shutdown Capability Project stage: Withdrawal NRC-2012-0196, South Texas Project, Units 1 and 2 - FRN - Withdrawal of License Amendment Request to Approve Revision to Fire Protection Program in Fire Hazards Analysis Report Related to Alternate Shutdown Capability (TAC Nos. ME6346 and ME6347)2012-08-14014 August 2012 South Texas Project, Units 1 and 2 - FRN - Withdrawal of License Amendment Request to Approve Revision to Fire Protection Program in Fire Hazards Analysis Report Related to Alternate Shutdown Capability (TAC Nos. ME6346 and ME6347) Project stage: Withdrawal 2011-08-01
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 July 22, 2011 Mr. Edward D. Halpin President and Chief Executive Officer/
Chief Nuclear Officer STP Nuclear Operating Company South Texas Project P. O. Box 289 VVadsworth, TX 77483
SUBJECT:
SOUTH TEXAS PROJECT, UNITS 1 AND 2 - LICENSE AMENDMENT REQUEST FOR APPROVAL OF A REVISION TO THE FIRE PROTECTION PROGRAM RELATED TO THE ALTERNATE SHUTDOVVN CAPABILlTY UNACCEPTABLE FOR REVIEVV VVITH OPPORTUNITY TO SUPPLEMENT (TAC NOS. ME6346 AND ME6347)
Dear Mr. Halpin:
By letter dated June 2,2011 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML11161A143), STP Nuclear Operating Company (STPNOC) submitted a license amendment request for South Texas Project (STP), Units 1 and 2. The proposed amendment would approve revision to the STP, Units 1 and 2, Fire Protection Program related to the Alternate Shutdown Capability. The purpose of this letter is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staff's acceptance review of this amendment. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review.
The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
Consistent with Section 50.90 of Title 10 of the Code of Federal Regulations (10 CFR), an amendment to the license (including the technical specifications) must fully describe the changes requested, and following as far as applicable, the form prescribed for original applications. Section 50.34 of 10 CFR addresses the content of technical information required.
This section stipulates that the submittal address the design and operating characteristics, unusual or novel design features, and principal safety considerations.
The NRC staff has reviewed your application and concluded that the following information is necessary to enable the NRC staff to make an independent assessment regarding the acceptability of the proposed amendment request in terms of regulatory requirements and the protection of public health and safety and the environment:
Please provide information to supplement the license amendment request in order to facilitate a comparison between the RETRAN analyses performed to support the Appendix R licensing request and a typical RETRAN analysis performed for a licensing basis event. Include information to compare key analytic inputs, and a summary description of the RETRAN results for the
Halpin
- 2 Appendix R analyses, including a discussion of the key figures of merit, limiting cases and results.
In order to make the application complete, the NRC staff requests that STPNOC supplements the application to address the requested information by July 27, 2011. This will enable the NRC staff to complete its detailed technical review. If the information responsive to the NRC staff's request is not received by the above date, the application will not be accepted for review pursuant to 10 CFR 2.101, and the NRC staff will cease its review activities associated with the application. If the application is subsequently accepted for review, you will be advised of any further information needed to support the NRC staff's detailed technical review by separate correspondence.
The information requested and associated time frame in this letter were discussed with Mr. Ken Taplett of your staff on July 13, 2011.
If you have any questions, please contact me at 301-415-3016 or via e-mail at Salwant.singal@nrc.gov.
Sincerely, f~ 'L~~T \\c/S,\\.--\\~Z C?\\
Salwant K. Singal, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-498 and 50-499 cc: Distribution via Listserv
E. Halpin
- 2 Appendix R analyses, including a discussion of the key figures of merit, limiting cases and results.
In order to make the application complete, the !\\IRC staff requests that STPNOC supplements the application to address the requested information by July 27, 2011. This will enable the NRC staff to complete its detailed technical review. If the information responsive to the NRC staff's request is not received by the above date, the application will not be accepted for review pursuant to 10 CFR 2.101, and the NRC staff will cease its review activities associated with the application. If the application is subsequently accepted for review, you will be advised of any further information needed to support the NRC staff's detailed technical review by separate correspondence.
The information requested and associated time frame in this letter were discussed with Mr. Ken Taplett of your staff on July 13, 2011.
If you have any questions, please contact me at 301-415-3016 or via e-mail at Balwant.singal@nrc.gov.
Sincerely, IRAI Balwant K. Singal, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-498 and 50-499 cc: Distribution via Listserv DISTRIBUTION: