ACCELERATED DI JRIUTION DEMONSTTION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9005100033 DOC.DATE: 90/04/06 NOTARIZED: YES DOCKET #

FACIL:50-305 Kewaunee Nuclear Power Plant, Wisconsin Public Servic 05000305 AUTH.NAME AUTHOR AFFILIATION EVERS,K.H.

Wisconsin Public Service Corp.

76

  • fS' Off3 7 RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

(1ey + )"

R

SUBJECT:

Forwards WCAP-12559 & proprietary WCAP-12558, "Kewaunee Steam Generator Tubesheet Crevice Indications Return...."

DISTRIBUTION CODE: AP01D COPIES RECEIVED:LTR ENCL L SIZE:

+ 73P TITLE: Proprietary Review Di tribu ion -

Operating Reactor NOTES:

p F

I RECIPIENT ID CODE/NAME PD3-3 LA DAVIS,MIKE COPIES LTTR ENCL 1

1 3

3 RECIPIENT ID CODE/NAME PD3-3 PD COPIES LTTR ENCL 1

1 INTERNAL: ACRS EXTE FILE LD01 EXTERNAL: LPDR 6

1 1

6 1

1 AEOD/DOA OGC/HDS1 1

VrbtPNRC PDR

(~(L~(~

cdt.

R I

D S

A D

D S

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED: LTTR 17 ENCL D

S A

D D

1 1

1 0

1 0

S 9/

-1

WPSC (414)433-1598 TELECOPIER (414] 433-5544 WE WISCONSIN PUBLIC SERVICE CORPORATION NRC-90-40 EASYLINK 62891993 600 North Adams

  • P.O. Box 19002
  • Green Bay, WI 54307-9002 April 6, 1990 U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555 Gentlemen:

Docket 50-305 Operating License DPR-43 Kewaunee Nuclear Power Plant Steam Generator Tube Concerns The enclosure to this letter formalizes the NRC during the meeting of March 28, 1990 in held to present the WPSC finding concerning generator tube inspection.

information Washington, the results presented by WPSC to the D.C. This meeting was of the 1990 KNPP steam The report includes a safety evaluation which concludes that KNPP remains within its design and licensing basis and that continued operation does not present an unreviewed safety question. In light of this determination, it is our intent to proceed with our scheduled startup without prior NRC review and approval.

Our current schedule places criticality on April 18, 1990. Notwithstanding the above, we are submitting this material for your information.

WPSC would like to take this opportunity to again express our appreciation for your prompt attention and dispatch with regard to this issue. If there are any questions regarding this information, please feel free to contact a member of my staff.

Sincerely, K. H. Evers Manager -

Nuclear Power DR/jms cc -

Mr. Patrick Castleman, US NRC US NRC, Region III Enc.

90c A O5100033 900406 PDR ADOCK 05000305 P'

PDC (Ia rc

0 0

Wisconsin Public Services Letter for Transmittal to the NRC THE FOLLOWING PARAGRAPHS SHOULD BE INCLUDED IN YOUR LETTER TO THE NRC:

Enclosed are:

1.

_L copies of WCAP-12558, "Kewaunee Indications Return to Power Report" Steam Generator Tube Sheet Crevice (PROPRIETARY).

2.

J_ copies of WCAP-12599, "Kewaunee Steam Generator Tube Indications Return to Power Report" (NON-PROPRIETARY).

Sheet Crevice Also enclosed is a Westinghouse authorization letter, CAW-90-025, Proprietary Information Notice, and accompanying Affidavit.

As Item 1 contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information The affidavit sets forth the basis on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.

Accordingly, it is respectfully requested that the information which is proprietary to Westinghouse be withheld from public disclosure in accordance with 10CFR Section 2.790 of the Commission's regulations.

Correspondence with respect to the proprietary aspects of the Application for Withholding or the supporting Westinghouse Affidavit should reference CAW-90-025 and should be addressed to R. A. Wiesemann, Manager of Regulatory &

Legislative Affairs, Westinghouse Electric Corporation, P.O. Box 355, Pittsburgh, Pennsylvania 15230-0355.

0 0

PROPRIETARY INFORMATION NOTICE TRANSMITTED HEREWITH ARE PROPRIETARY AND/OR NON-PROPRIETARY VERSIONS OF DOCUMENTS FURNISHED TO THE NRC IN CONNECTION WITH REQUESTS FOR GENERIC AND/OR PLANT SPECIFIC REVIEW AND APPROVAL.

IN ORDER TO CONFORM TO THE REQUIREMENTS OF 10CFR 2.790 OF THE COMMISSION'S REGULATIONS CONCERNING THE PROTECTION OF PROPRIETARY INFORMATION SO SUBMITTED TO THE NRC, THE INFORMATION WHICH IS PROPRIETARY IN THE PROPRIETARY VERSIONS IS CONTAINED WITHIN BRACKETS AND WHERE THE PROPRIETARY INFORMATION HAS BEEN DELETED IN THE NON-PROPRIETARY VERSIONS ON THE BRACKETS REMAIN, THE INFORMATION THAT WAS CONTAINED WITHIN BRACKETS AND WHERE THE PROPRIETARY INFORMATION HAS BEEN DELETED IN THE NON-PROPRIETARY VERSIONS ONLY THE BRACKETS REMAIN, THE INFORMATION THAT WAS CONTAINED WITHIN THE BRACKETS IN THE PROPRIETARY VERSIONS HAVING BEEN DELETED. THE JUSTIFICATION FOR CLAIMING THE INFORMATION SO DESIGNATED AS PROPRIETARY IS INDICATED IN BOTH VERSIONS BY MEANS OF LOWER CASE LETTERS (a) THROUGH (g) CONTAINED WITHIN PARENTHESES LOCATED AS A SUPERSCRIPT IMMEDIATELY FOLLOWING THE BRACKETS ENCLOSING EACH ITEM OF INFORMATION BEING IDENTIFIED AS PROPRIETARY OR IN THE MARGIN OPPOSITE SUCH INFORMATION. THESE LOWER CASE LETTERS REFER TO THE TYPES OF INFORMATION WESTINGHOUSE CUSTOMARILY HOLDS IN CONFIDENCE IDENTIFIED IN SECTIONS (4)(ii)(a) THROUGH (4)(ii)(g) OF THE AFFIDAVIT ACCOMPANYING THIS TRANSMITTAL PURSUANT TO 10CFR2.790(b)(1).