UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001

..Ji..lre 13, 2011 Mr. Michael J. Pacilio President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, IL 60555

SUBJECT:

BYRON STATION, UNIT NOS. 1 AND 2 - CORRECTION TO ISSUANCE OF LICENSE AMENDMENT NO. 171, RE: TECHNICAL SPECIFICATION (TS)

CHANGE FOR THE RELOCATION OF SPECIFIC SURVEILLANCE FREQUENCY REQUIRMENTS BASED ON TSTF-425 (TAC NOS. ME3368 AND ME3369)

Dear Mr. Pacilio:

By letter dated February 24,2011 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML110060811), the U.S. Nuclear Regulatory Commission (NRC) issued Amendment No. 171 to Facility Operating License No. NPF-37 and Amendment No. 171 to Facility Operating License No. NPF-66. After issuance, it became apparent a revision bar to the revised NOTE contained in surveillance requirement (SR) 3.3.1.8 had been omitted.

Enclosed is the corrected TS page 3.3.1-11. This error did not impact Amendment No. 171 as this is an administrative correction and does not change the NRC staff conclusions.

We regret any inconvenience this may have caused. ShOUld you have any questions regarding this matter, please contact me at (301) 415-1115.

Sincerely, Nicholas J. DiFrancesco, Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-454 and 50-455

Enclosure:

As stated cc: Distribution via Listserv

RTS Instrumentation 3.3.1 SURVEILLANCE REQUIREMENTS (continued)

SURVEI LLANCE FREQUENCY SR 3.3.1.8


--NOTE-------------

This Surveillance shall include verification that interlocks P-6 and P-10 are in their required state for existing unit conditions.

Perform COT.


NOTE---

Only requi red when not performed within the Frequency specified in the Surveillance Frequency Control Program Prior to reactor startup AND Four hours after reducing power below P-10 for power and i ntermedi ate instrumentation AND Four hours after reduc"j ng power below P-6 for source range instrumentation AND In accordance with the Surveillance Frequency Control Program (continued)

BYRON UNITS 1 & 2 3.3.1 11 Amendment 171/171

June 13, 2011 Mr. Michael J. Pacilio President and Chief Nuclear Officer Exelon Nuclear 4300 Winfield Road Warrenville, I L 60555

SUBJECT:

BYRON STATION, UNIT NOS. 1 AND 2-CORRECTION TO ISSUANCE OF LICENSE AMENDMENT NO. 171, RE: TECHNICAL SPECIFICATION (TS)

CHANGE FOR THE RELOCATION OF SPECIFIC SURVEILLANCE FREQUENCY REQUIRMENTS BASED ON TSTF-425 (TAC NOS. ME3368 AND ME3369)

Dear Mr. Pacilio:

By letter dated February 24, 2011 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML110060811), the U.S. Nuclear Regulatory Commission (NRC) issued Amendment No. 171 to Facility Operating License No. NPF-37 and Amendment No. 171 to Facility Operating License No. NPF-66. After issuance, it became apparent a revision bar to the revised NOTE contained in surveillance requirement (SR) 3.3.1.8 had been omitted.

Enclosed is the corrected TS page 3.3.1-11. This error did not impact Amendment No. 171 as this is an administrative correction and does not change the NRC staff conclusions.

We regret any inconvenience this may have caused. Should you have any questions regarding this matter, please contact me at (301) 415-1115.

Sincerely, IRA!

Nicholas J. DiFrancesco, Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Reguration Docket Nos. 50-454 and 50-455

Enclosure:

As stated cc: Distribution via Listserv DISTRIBUTION:

PUBLIC LPL3-2 RlF RidsNrrLASRohrer Resource RidsNrr DorlLpl3-2 Resource RidsNrrPMByron Resource RidsAcrs_MailCTR Resoruce RidsRgn3MailCenter Resource ADAMS Accession no ML111600029 NRR-106 OFFICE LPL3-2/PM LPL3-21LA LPL3-2/BC NAME NDiFrancesco SRohrer JZimmerman DATE 6/9/11 6/9/11 6/13/11 OFFICIAL RECORD COpy