Potential Defect in Certain Velan Supplied Globe Valves
ML11159A030
Person / Time
Site: Millstone 
Issue date: 06/03/2011
From: Apostolescu V
Velan
To:
Office of Nuclear Reactor Regulation
References
46923
Download: ML11159A030 (6)


Text

46923 Part 21 (PAR)

U.S. Nuclear Regulatory Commission Operations Center Event Report 06/06/2011 Page 1 Event #

VELAN INC VICTOR APOSTOLESCU BILL HUFFMAN 06/03/2011 04/12/2011 16:30 06/03/2011 RICHARD CONTE JOSELITO CALLE ROBERT DALEY BLAIR SPITZBERG PT 21 GRP VIA E-MAIL R1DO R2DO R3DO R4DO UNSPECIFIED PARAGRAPH NRC Notified by:

HQ Ops Officer:

Notification Date / Time:

Event Date / Time:

Last Modification:

Rep Org:

10 CFR Section:

Notifications:

NON EMERGENCY Emergency Class:

VELAN INC Region:

City:

QUEBEC County:

CANADA State:

Docket #:

License #:

Agreement State:

No (EDT)

(EST)

Supplier:

21.21 POTENTIAL DEFECT IN CERTAIN VELAN SUPPLIED GLOBE VALVES The following is a summary of a Part 21 e-mail notification received from Velan Inc:

Velan Inc., a valve vendor, has identified a potential defect in certain lots of 0.5, 0.75 and 1 inch NPS globe valves sold to Areva and Fenoc. The failure could result in the valve travelling into the bonnet cavity and became jammed between body and bonnet. The analysis revealed that the failure was caused by the wrong bonnet being installed on the valve which ultimately allowed the disc to travel too far into the bonnet cavity and consequently the disc dropped into the body-bonnet gap. This prevented the valve from being closed during manual operation.

Internal analysis also determined that this failure mode is very plausible in valves installed with the stem in a horizontal orientation. Valves installed with the stem in vertical orientation are far less likely to fail but we cannot guarantee that; on valves that are normally fully open certain flow conditions may cause the disc to tilt and jam between body and bonnet. Nevertheless, operational history seems to suggest that valves installed with the stem in vertical orientation have not experienced this type of failure.

Velan has requested that each affected utility reviews the individual applications for the specific valves identified in this notification; in the event of any application where the valves inability to close will impact significantly the safe operation of the plant. Velan will work with the utility towards reaching a suitable solution.

Velan does not have specific information concerning the specific system and function applicable to these globe valves and therefore we cannot assess whether a substantial safety hazard exists as a result of their inability to close after falling as described above.

Velan's investigation and review of the available manufacturing records revealed that the same bonnet, with an

46923 Part 21 (PAR)

U.S. Nuclear Regulatory Commission Operations Center Event Report 06/06/2011 Page 2 Event #

oversized lift, was installed in all valves identified hereunder.

CUSTOMER ORDER QTY. VALVE FIGURE No. VALVE SERIAL No.

AREVA NP 8 W04-2074B-02AA 971022-1 to-8 AREVA NP 12 W03-2074B-02AA 971042-1 to -12 AREVA NP 27 W04-2074B-02AA 971048-1 to -27 AREVA NP 5 W03-2074B-02AA 981028-1 to-5 AREVA NP 5 W03-20748-02AA 981030-1 to-5 AREVA NP 10 W05-20748-02AA 001012-1 to-10 AREVA NP 13 W03-20748-02AA 001029 -1 to -13 AREVA NP 26 W04 20748-02AA 001056 -1 to -26 ARE VA NP 10 W04-20748-02AA 011035-1 to-10 FENOC 4 W05-2074B 02AA 001033 -1 to-4

CERTIFIED TO ISO 9001 QUALITY STANDARDS June 3, 2011 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001 Attention:

Document Control Desk, via fax 301-816-5151

Subject:

Globe Valve Notification, sizes 0.5, 0.75 and 1 NPS, Class 800, Carbon Steel Note:

Similar Notifications were sent to Areva and First Energy Gentlemen, On April 12, 2011 Velan was notified by Dominion Connecticut that a 0.5 NPS globe valve model number W03-2074B-02AA, Velan drawing P1-76800-N03 installed at Millstone 2 in a non-safety related portion of the main-steam system could not be closed when operated by its handwheel.

The valve was installed with the stem in a horizontal orientation; during the installation and commissioning procedure the valve was fully open (on the back seat position). The disc travelled into the bonnet cavity and became jammed between body and bonnet; the sketch in Exhibit # 1 shows the failure mode.

The analysis revealed that the failure was caused by the wrong bonnet being installed on the valve which ultimately allowed the disc to travel too far into the bonnet cavity and consequently the disc dropped into the body-bonnet gap.

This prevented the valve from being closed during manual operation. The event is covered by Millstone 2 OE 33277.

The valve subject of OE 33277 was part of a lot of 13 sold to Areva on their PO 87561, Velan PO P011-909330-N, item 11, and later sold to Millstone.

Our investigation and review of the available manufacturing records revealed that the same bonnet, with an oversized lift, was installed in all valves identified hereunder.

CUSTOMER VELAN PO No.

VELAN ITEM No.

CUSTOMER PO No.

ORDER ITEM No.

QTY.

VALVE FIGURE No.

VALVE SERIAL No.

AREVA NP P1-81483-N 0001A 56333 1A 8

W04-2074B-02AA 971022-1 to -8 AREVA NP P1-81510-N 00001 56892 1

12 W03-2074B-02AA 971042-1 to -12 AREVA NP P1-81510-N 00002 56892 2

27 W04-2074B-02AA 971048-1 to -27 AREVA NP P1-81781-N 00001 62979 1

5 W03-2074B-02AA 981028-1 to -5 AREVA NP P1-81833-N 00002 63980 2

5 W03-2074B-02AA 981030-1 to -5 AREVA NP P011-909260-N 00001 88118 1

10 W05-2074B-02AA 001012-1 to -10 AREVA NP P011-909330-N 00011 87561 11 13 W03-2074B-02AA 001029 -1 to -13 AREVA NP P011-927040-N 00001 91880 1

26 W04-2074B-02AA 001056 -1 to -26 AREVA NP P011-991170-N 00026 97049 26 10 W04-2074B-02AA 011035 -1 to -10 FENOC P011-854880-N 00001 7016078 1

4 W05-2074B-02AA 001033 -1 to -4 VELAN Inc.

7007 Cote de Liesse, Montreal Quebec, Canada H4T 1G2 Tel: (514) 748-7743 Fax: (514) 748-7592

CERTIFIED TO ISO 9001 QUALITY STANDARDS Our internal analysis also determined that this failure mode is very plausible in valves installed with the stem in a horizontal orientation. V alves in stalled with th e s tem in vertical orientation are f ar l ess l ikely t o f ail but w e c annot guarantee that; on valves that are normally fully open certain flow conditions may cause the disc to tilt and jam between body and bo nnet. Nevertheless, operational history s eems t o s uggest that va lves installed with th e s tem in v ertical orientation have not experienced this type of failure.

We do not have specific information concerning the specific system and function applicable to these globe valves and therefore we cannot assess whether a substantial safety hazard exists as a result of their inability to close after failing as described above.

We requested that each affected utility reviews the individual applications for the specific valves identified in this notification; in the event of any application where the valves inability to close will impact significantly the safe operation of the plant Velan will work with the Utility towards reaching a suitable solution.

Root cause and corrective action Prior to 1984 Velan employed a disc-union to connect the disc with the valve stem. In 1984 a new design was introduced, using a horseshoe disc thereby eliminating the need for a disc-union and the welding required to assemble the disc to the disc-union. The old design, using bonnet part number 3523-010 was reserved afterwards for military applications.

The new design, intended for all commercial and nuclear applications, also used a new bonnet (part 3524-037), with a lower backseat necessary to accommodate the shorter lift as a result of the disc-union being eliminated.

Exhibit # 2 displays two stems, showing the aforementioned methods used to connect the disc to the stem.

Due to the bonnet part 3523-010 being nearly identical with the new bonnet, 3524-037, it was incorrectly deemed interchangeable for the latter and used in a small number of instances identified in the above table.

In 2003 an Engineering review identified the potential for this type of failure on valves installed with the stem in a horizontal orientation. Consequently, the existing stock of bonnets suitable for valves using the disc-union connection was scrapped immediately. Because the operational feed-back did not indicate any field problems at the time, the analysis failed to recognize the potential impact on valves assembled with old bonnets used in safety-related applications.

Corrective actions to eliminate the recurrence of such events are under review.

For any addi tional i nformation on t his m atter pl ease c ontact m e at 51 4-748-7748 x 1134 or at victor.apostolescu@velan.com.

Sincerely yours, Velan Inc.

Victor Apostolescu, Eng.

Vice President Quality Assurance cc:

Velan - T. Velan, I. Velan, G. Perez, J. Tsesmelis; C. Minescu, C. Schweiger (via e-mail)

CERTIFIED TO ISO 9001 QUALITY STANDARDS Exhibit # 1

CERTIFIED TO ISO 9001 QUALITY STANDARDS Exhibit # 2