2010 PALISADES NUCLEAR PLANT INITIAL EXAM1 NATION ADMINISTRATIVE FILES

ination Preparation Checklist Form ES-201-1

-14 Facility:

I

10.

Final license applications due and Form ES-201-4 prepared (C.1.I; C.2.i; ES-202)

Date of Examination: 2 010

-14

-1 4 Target Date*

11.

Examination approved by NRC supervisor for facility licensee review (C.2.h; C.3.f)

Examinations reviewed with facility licensee (C.1.j; C.2.f and h; C.3.g)

12.

-180

-7 11 Developed by: Written - Facility a NRC 0

// Operating - Facility @ NRC c]

Chief Initials Task Description (Reference)

Examiner's

1.
2.
3.
4.

Examination administration date confirmed (C.l.a; C.2.a and b)

NRC examiners and facility contact assigned (C.l.d; C.2.e)

Facility contact briefed on security and other requirements (C.2.c)

Corporate notification letter sent (C.2.d)

13.

Written examinations and operating tests approved by NRC supervisor (C.2.i; C.3.h)

-1 20

-7

-120

14.

Final applications reviewed; 1 or 2 (if >lo) applications audited to confirm qualifications / eligibility; and examination approval and waiver letters sent (C.2.i; Attachment 5; ES-202, C.2.e; ES-204)

Proctoring/written exam administration guidelines reviewed with facility licensee (C.3.k)

15.

-1 20

~~~

~~

[5.

Reference material due (C.1.e; C.3.c; Attachment 3)]

6.

Integrated examination outline(s) due, including Forms ES-201-2, ES-201-3, ES-301-1, ES-301-2, ES-301-5, ES-D-l's, ES-401-1/2, ES-401-3, and ES-401-4, as applicable (C.l.e and f; C.3.d)

{-70) 1 (7.

Examination outline(s) reviewed by NRC and feedback provided to facility licensee (C.2.h; C.3.e))

{-451

8.

Proposed examinations (including written, walk-through JPMs, and scenarios, as applicable), supporting documentation (including Forms ES-301-3, ES-301-4, ES-301-5, ES-301-6, and ES-401-6, and any Form ES-201-3 updates), and reference materials due (C.l.e, f, g and h; C.3.d)

-30 I 9-Preliminary license applications (NRC Form 398's) due (C.l.I; C.2.g; ES-202)

II I

I I SP ll

-7

16.

Approved scenarios, job performance measures, and questions distributed to NRC examiners ((2.34 IK

  • Target dates are generally based on facility-prepared examinations and are keyed to the examination date identified in the corporate notification letter. They are for planning purposes and may be adjusted on a case-by-case basis in coordination with the facility licensee.

[Applies only] {Does not apply) to examinations prepared by the NRC.

~

~

~~

ES-201 Examination Security Agreement Form ES-201-3

1.

Pre-Examination

?&ge I O F 3 I acknowledge that I have acquired specialized knowledge about the NRC licensing examinations scheduled for the week(s) of 8/16/2010 and 8/23/2010 as of the date of my signature. I agree that I will not knowingly divulge any information about these examinations to any persons who have not been authorized by the NRC chief examiner. I understand that I am not to instruct, evaluate, or provide performance feedback to those applicants scheduled to be administered these licensing examinations from this date until completion of examination administration, except as specifically noted below and authorized by the NRC (e.g., acting as a simulator booth operator or communicator is acceptable if the individual does not select the training content or provide direct or indirect feedback). Furthermore, I am aware of the physical security measures and requirements (as documented in the facility licensee's procedures) and understand that violation of the conditions of this agreement may result in cancellation of the examinations andlor an enforcement action against me or the facility licensee. I will immediately report to facility management or the NRC chief examiner any indications or suggestions that examination security may have been compromised.

2.

Post-Examination To the best of my knowledge, I did not divulge to any unauthorized persons any information concerning the NRC licensing examinations administered during the week(s) of 8/16/2010 and 8/23/2010. From the date that I entered into this security agreement until the completion of examination administration, I did not instruct, evaluate, or provide performance feedback to those applicants who were administered these licensing examinations, except as specifically noted below and authorized by the NRC.

1. TEFFBEf ILlff Lf,f/~h DEVL'LD?ER
3. V/&rhjtA L-hCclau 0 P m od3 m&%mble
4. DQrl;c) &2,I
7.

ht, i7 ' Se+rfitbi

8.

MfW-bFf

9. w\\lc,l-b@& LmT
11. l. - - - 4, 4 j L
13. <mot'kv C(%J 1 4. &?Ab-
15. MJ1;L ~ ~ L w \\ \\ s
16. %,n f? E3-
17.

0k-cn-,

18.

fi-mh5 NOTES:

PRINTED NAME JOB TITLE / RESPONSIBILITY

2.

)?GN.4t3 J-i-pl &o

&q 7

DC+C io P K 5

L zy,Ge/d5

6.

~ P k f TARLehJD I O. L C a 7 T 7. fim&d e D - 5 0

/

12. J - O L L & L <

ES-201 Examination Security Agreement Form ES-201-3

1.

Pre-Examination I -'

I I

I To the best of my knowledge, I did not divulge to any unauthorized persons any information concerning the NRC licensing examinations administered administration, I did not instruct, evaluate, or provide performance feedback to those applicants who were administered these licensing examinations, during the week(s) of 8/16/2010 and 8/23/2010. From the date that I entered into this security agreement until the completion of examination except as specifically noted below and authorized by the NRC.

I acknowledge that I have acquired specialized knowledge about the NRC licensing examinations scheduled for the week(s) of 8/16/2010 and 8/23/2010 as of the date of my signature. I agree that I will not knowingly divulge any information about these examinations to any persons who have not been authorized by the NRC chief examiner. I understand that I am not to instruct, evaluate, or provide performance feedback to those applicants scheduled to be administered these licensing examinations from this date until completion of examination administration, except as specifically noted below and authorized by the NRC (e.g., acting as a simulator booth operator or communicator is acceptable if the individual does not select the training content or provide direct or indirect feedback). Furthermore, I am aware of the physical security measures and requirements (as documented in the facility licensee's procedures) and understand that violation of the conditions of this agreement may result in cancellation of the examinations and/or an enforcement action against me or the facility licensee. I will immediately report to facility management or the NRC chief examiner any indications or suggestions that examination security may have been compromised.

2.

Post-Examination

17.
18.

NOTES:

ES-201 ExaminationSacurltyAgreeme nt F

o

~

ES-2015 I acknowtedge that I have acquired spedalked hodedge about the NRC licensing examinations scheduled for the week($) of % 1692 as of the date of my signature. I agree that 1 All not knowingly d i

any inhnation about these eweminations to any penions who haw not b n authorized by the NRC chef examiner. I understand that I am not bo instruct, evaluaw, or provide performance feedback bo those applicants sdrsduled to be administered these licensing axarnhtiom from this date until completion ofexrmination admlnistratkn. exapt as spedffcally noted below and auMorirsd by the NRC (e.g., acting 45 a simulator booth opentor or communicator is acceptabie if the individual does nat seled the training content 01 provide direct 01 indirect feedback). Furthefmore, I am aware of the physical sccurlty masum and requirements (as r.bcmwW in the fscility kensee's procedures) and understand that vidation of the condition0 of this agreement may result in cancellarion d the examinations and/or an enforcement adion against me or the facility license%. I wi# immediately r%port to tacifi management or the NRC chief examiner any indications or wggwtbns that axambtm. nsscwity may have been compfwnised.

2 P

To the best of my knowledge. I did not divulge to any unauthorized persons any information Concsming the NRC liensing examinations adminiitered during the week(s) of

. From the date that lentered mtotMsswxlrity agreement untilthb c~npletrorrofsramlnation admhktmtm

.,Ididnot instruct. evaluate. or prOvi8e performanet feedback to those applicants who were admhbtw ed these lkmsing exanrinrtiona. exmpt as specitiUlfy noted b e h and authorized by the NRC.

ES-201, Paae 27 of 28

-~

ES-401 Record of Rejected WAS Form ES-401-4 017 K2 072 K6 Tier I Randomly Group Selected KIA All statements in this category have an importance rating <2.5. Resampled and obtained 01 7 A4.01.

All statements in this category have an importance rating <2.5. Resampled and obtained 072 AI.01.

Reason for Rejection 3

111 G2.4.49 Unable to develop an operationally valid, discriminatory exam question due to no credible relationship between immediate operator actions without reference to procedures and 10CFR55.43(b) topics. Resampled and obtained G2.4.29.

1 I1 1 I1 1 I1 1 I2 211 211 211 211 211 211 212 212 022 AK3.06 025 AAI.11 038 EK1.03 062 AK2 051 AK1 005 A3 006 K1.12 007 K2 059 K2 RO Exam Unable to develop an operationally valid discriminatory exam question due to no credible relationship between loss of reactor coolant makeup and RCP thermal barrier cooling.

Resampled and obtained 022 AK3.05.

Unable to develop an operationally valid discriminatory exam question due to no credible relationship between loss of RHR and Reactor building sump level indicators.

Resampled and obtained 025 AA1.09.

Unable to develop an operationally valid discriminatory exam question due to similarities with RO question #3. Resampled and obtained 038 EK1.02.

There are no statements for this category. Resampled and obtained 062 AA1.06.

All statements in this category have an importance rating <2.5. Resampled and obtained 051 AA2.02.

There are no statements for this category. Resampled and obtained G2.2.37.

Importance rating <2.5. Resampled and obtained 006 K1.03 There are no statements for this category. Resampled and obtained 007 K4.01.

All statements in this category have an importance rating e2.5. Resampled and obtained 059 K3.04.

063 K5 I All statements in this category havean importance rating <2.5. Resampled and obtained 063 K6 063 A2.01.

All statements in this category have an importance rating <2.5. Resampled and obtained 063 Al.01.

I SRO Exam ES-401, Page 27 of 33

K/A Selection Methodology and Suppression Report

1.

The systematic and random sampling of WAS for the Palisades Nuclear Plant August 2010 Written Exam was performed in accordance with the following:

a.

NUREG-1021, Rev. 9 Supplement 1, ES-401, Attachment 1, "Example Systematic Sampling Methodology".

b.

NUREG-I021 I Rev. 9 Supplement 1, ES-401, D.l.b.

2.

WA Suppression:

Suppression of any WAS was minimal and in accordance with the guidance mentioned in Step 1 of this methodology document. WA suppression was as follows:

Fifteen Tier 1 WA topics were suppressed that are vendor specific to a plant design other than Combustion Engineering. The following are the Tier 1 WA topics that were suppressed:

WE04 LOCA Outside Containment I 3

WE1 1 Loss of Emergency Coolant Recirc. I 4 BWE04; WE05 Inadequate Heat Transfer - Loss of Secondary Heat Sink I 4 WE01 8 E02 Rediagnosis & SI Termination I 3 WE13 Steam Generator Over-pressure I 4 WE15 Containment Flooding I 5 WE16 High Containment Radiation 19 BWIAOI Plant Runback I 1

BWlAO28AO3 LOSS d NNI-XN I 7

BWlAO4 Turbine Trip I 4 BWlAO7 Flooding I 8 BWIAOS Emergency Diesel Actuation I 6 BWEO3 Inadequate Subcooling Margin I 4 BWEO8; WE03 LOCA Cooldown - Depress. I 4 BWE13BE14 EOP Rules and Enclosures One Tier 2 WA topic, "025 Ice Condenser" was suppressed due to prior knowledge that Palisades design does not use an ice condenser.

3.

Tier 1 and Tier 2 randomly selected generic category ("G") WAS were selected from the 41 generic WAS listed in ES-401, section D.l.b.

4.

SRO Only questions - WAS were randomly selected from either the "A2" or "G" categories. This was completed per ES-401 I Attachment 1, Item 4.

5.

Numbered tokens were used and were manually and randomly selected from a large cup. NO automatic generation software was used in the selection process.

6.

After initial random selection a total of 14 WAS were rejected for various reasons, as documented on Form ES-401-4, "Record of Rejected WAS", as required.

Palisades Nuclear Plant August 2010 Initial License Exam

ES-403 Written Examination Grading Form ES-403-1 Quality Checklist Facility: Palisades Date of Exam: August 27th, 2010 Exam Level: RO IXI SR(

Initial I

Item Description

1.

Clean answer sheets copied before grading

2.
3.
4.

Answer key changes and question deletions justified and documented Applicants' scores checked for addition errors (reviewers spot check >25% of examinations)

Grading for all borderline cases (80% f 2% overall and 70 or 80, as applicable, +. 4% on the SRO-onlv) reviewed in detail

5.
6.

All other failing examinations checked to ensure that grades are justified Performance on missed questions checked for training deficiencies and wording problems; evaluate validity of questions missed by half or more of the applicants C

Date

a. Author ai2712010
b. Facility Reviewer(*)

8/27/20 10

c. NRC Chief Examiner(*)

%/h//O

d. NRC Supervisor(*)

(*)

The facility reviewer's signature is not applicable for examinations graded by the NRC; two independent NRC reviews are required.

ES-403, Page 5 of 5

ES-401 Written Examination Review Worksheet Form ES-401-9

  • QUESTION REVIEWED AS PART OF THE ES-401 SAMPLE I

I I

I Q#

1 2

3" 4

5 6

7'

1.
2.
3.
4.
5.
6.
7.
8.

Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.

Enter the level of difficulty (LOD) of each question using a 1 - 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).

Check the appropriate box if a psychometric flaw is identified:

The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information)

The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).

The answer choices are a collection of unrelated true/false statements.

The distractors are not credible; single implausible distractors should be repaired, more than one is unacceptable.

One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).

Check the appropriate box if a job content error is identified:

The question is not linked to the job requirements (Le., the question has a valid WA but, as written, is not operational in content).

The question requires the recall of knowledge that is too specific for the closed reference test mode (i.e., it is not required to be known from memory).

The question requires reverse logic or application compared to the job requirements.

The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

Check auestions that are samDled for conformance with the approved WA and those that are designated SRO-on/y (WA and license level mismatches are unacceptable).

Enter question source: (B)ank, (M)odified, or (N)ew. Check that (M)odified questions meet criteria of ES-401 Section D.2.f.

Based on the reviewer's judgment, is the question as written (U)nsatisfactory (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?

At a minimum, explain any " U ratings (e.g., how the Appendix B psychometric attributes are not being met).

ES-401 2

Form ES-401-9 Explanation If.d was true then b. would also be true. But there can only be one correct answer therefore.d cannot be true. RESOLUTION:

Distractors reworded.

Will not heat removal via the SGs be adversely impacted by PCP trip? = 2 correct answers b & c. RESOLUTION: Natural circulation will allow heat removal therefore ability to remove heat is maintained.

? Why isnt this a memory question ? LOK=L? RESOLUTION:

Changed to L Question = ATWS not Dropped Rod. RESOLUTION: Question replaced

1.
2.
3. Psychometric Flaws
4. Job Content Flaws Q#

LOK LOD (F/H)

(1-5) Stem Cues T/F Cred. Partial Job-Minutia

  1. /

Back-Focus Dist.

Link units ward 24 H

3 25*

L 3

5. Other
6.
7.
8.

Q= SRO B M N u/E/s Explanation WA Only Y

B E

Change stem to make it clear RIA -2317 has not reached the alarm set point. Change a. to...are both required to cause an alarm.

RESOLUTION: Change made.

Y N

S

ES-401 2

Form ES-401-9 I

I

4. Job Content Flaws
5. Other I 6.
1. I 2. 1 3,. Psychometric LOK LOD FW (1-5) Stem Cues Focus 4

Flaws

7.
8.

JIWS Explanation

=red.

Dist.

Q=

WA Y -

S I Y

Y -

S S

Y S I Y

Y Y

S I I

S S

Y N -

Y S

I This question has 3 problems. 1) It does not match the KA which asks how the quench tank is cooled, not how steam entering the tank is cooled. 2) The question can be answered without use of the stem.

3) It is not credible that steam would be discharged above the water in a quench tank, ie. 2 non-credible distracters. RESOLUTION:

Question replaced.

Is not the rupture disk is expected to rupture if a relief valve fails open? Hi quench tank pressure would be expected to alarm. Also the tank may be > IOpsig with the rupture disk blown and the relief stuck open. Therefore a. not b. could be the correct answer.

RESOLUTION: Question replaced.

Y Y

Why wouldn't CCW pressure drop to c 80 psig on a loss of offsite power. Therefore c. not b. could be the correct answer.

Y S I Y

S I

ES-401 2

Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (FN)

(1-5) Stem Cues T/F Cred. Partial Job-Minutia

  1. /

Back-Q= SRO BIMIN UWS Explanation Focus Dist.

Link units ward WA Only 55' L

2 Y

N S

ES-401 2

Form ES-401-9 I

I I

I I

I I

I

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H)

(1-5)

Stem Cues T/F Cred. Partial Job-Minutia

  1. /

Back-Q= SRO 6/M/N u/E/s Explanation Focus Dist.

Link units ward WA Only 75 H

2 Y

B E

change stem to Which one of the following load drops will put D/G 1-1 closest to and below the continuous operational load limit?"

RESOLUTION:

Stem changed.

76' H

2 Y

Y M

S 77 H

3 Y

Y N

S 78*

H 2

Y Y

B S

79 H

2 Y

Y B

S 80' H

3 Y

Y N

S 81 H

3 Y

Y M

S 82 L

4 Y

Y B

S 83 H

2 Y

Y B

S 84' H

2 Y

Y B

s 85 H

2 Y

Y B

s 86 H

3 Y

Y N

S 87 H

3 Y

Y B

S 88, H

4 Y

Y N

S 89 H

3 Y

Y N

S

ai J

The licensee Outline was accepted as submitted.

OPERATING TEST COMMENTS Scenario 1 Add to Turnover that turbine testing is planned. (done)

Add RO actions for boration. (done)

Scenario 2 Remove event 3 it is same as JPM D. (done)

Scenario 3 In event 3 add that BOP may be directed to do back panel check. (done)

In event 4 add that SRO may direct refill of T-1OA. (done)

Scenario Spare In event 3 change 72-hour Tech Spec calls to 7-day and 30-day actions. (done)

JPMs ALL change to add cue to provide procedures (done)

JPM RO ADM l a Change answer key to match procedure Attachment 2 (done)

JPM RO ADM 3 Add contamination zone around pump. (done)

JPM SRO ADM 2 Change JPM to faulted by having data sheet call for load path 2. (done)

JPM SYS K Add cue for amp meter reading if candidate does not push pushbutton. (done)

Entergy Nuclear Operations, Inc.

Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Hugh Nixon Training Manager Entwg-y September Is', 2010 Mr. Bruce Palagi U.S.

Nuclear Regulatory Commission Region 111 2443 Warrenville Road Suite 21 0 Lisle, IL 60532-4352

Dear Mr. Palagi:

The purpose of this letter is to notify you that there were no comments by the applicants concernin the Initial Licensed Operator Written Examination that was administered on August 27 B,2010.

Please contact Jeffrey lliff at (269) 764-2974 if you have any questions.

Hudh ixon T r a w g Manager Entergy Nuclear Operations, Inc.

Palisades Nuclear Plant

Questions asked bv applicants durinq written exam

1.
2.
3.
4.
5.
6.
7.
8.
9.

I O.

RO Question 40. 55-33414 asked if Safety Injection has been blocked with the push buttons on C-I 3 or disabled by pulling fuses. Proctor reply: Safety Injection has been blocked per the initial conditions of the question.

SRO Question 76. 55-3341 4 asked which Battery Chargers are initially in service.

Proctor reply: Re-read the question.

RO Question 22. 55-33483 asked how many Charging Pumps were in service and how many Letdown Orifice Stop Valves were open. Proctor reply: P-55A, Charging Pump, is in service. Provided to all applicants by writing on white board and calling attention to the additional information.

RO Question 61. 55-32201 asked if the SFP heatup rate was linear. Proctor reply:

Re-read the question.

RO Question 40. 55-33413 asked if the CHP signal was still standing or if it was spurious (came in and cleared). Proctor reply: The CHP signal is still standing.

Provided to all applicants by writing on white board and calling attention to the additional information.

RO question 20.55-33482 asked if the effects were for a specific NI channel or for overall effects on Nls. Proctor reply: Re-read the question.

RO Question 47. 55-33414 asked if the question should be answered per actual current plant conditions. Proctor reply: Answer based on actual current plant conditions per the Appendix E brief prior to the start of the exam. Did not provide this to all applicants because this was discussed prior to the start of the exam.

RO Question 64. 55-33414 asked if the noun name for RIA-2300 was correct and could the official noun name be supplied. Proctor reply: RIA-2300 noun name is Radwaste Engineered Safeguard Room Monitor. Provided to all applicants by writing on white board and calling attention to the additional information.

SRO Question 79. 55-33414 asked why EOP-7.0 was entered if P-8C was available. Proctor reply: Re-read the question.

RO Question 61. 55-33414 asked if the answer was based on the design temperature limit for the SFP. Proctor reply: Re-read the question.