1 NRR-PMDAPEm Resource From:
Stang, John Sent:
Wednesday, December 15, 2010 7:38 AM To:
Todd, Randall P; Meixell, Bob Cc:
Kulesa, Gloria
Subject:
RR 10-ON-001 Pleasegivemeacall
ByletterdatedJune9,2010,DukeEnergyCarolinas,LLC(thelicensee)submittedRequestforAlternativeNo.10ON001 relatedtotheinspectionofspecifiedAmericanSocietyofMechanicalEngineersBoilerandPressureVesselCodeClass2 ResidualHeatRemovalHeatExchangerwelds(thesubjectRHRHXwelds)atOconeeNuclearStation,Units1,2,and3.
TheNRCstaffdeterminedthatadditionalinformationisrequiredtocompleteitsevaluationofthelicenseesrequest.
Thestaffsrequestforadditionalinformationisprovidedbelow.
- 1. Please state whether previous inservice inspections of the RHR HXs have detected any signs of leakage or age-related degradation in the subject RHR HX welds at Oconee Nuclear Station, Units 1, 2, and 3.
JohnStang 3014151345
Hearing Identifier:
NRR_PMDA Email Number:
40 Mail Envelope Properties (John.Stang@nrc.gov20101215073800)
Subject:
RR 10-ON-001 Sent Date:
12/15/2010 7:38:08 AM Received Date:
12/15/2010 7:38:00 AM From:
Stang, John Created By:
John.Stang@nrc.gov Recipients:
"Kulesa, Gloria" <Gloria.Kulesa@nrc.gov>
Tracking Status: None "Todd, Randall P" <Randall.Todd@duke-energy.com>
Tracking Status: None "Meixell, Bob" <Bob.Meixell@duke-energy.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 836 12/15/2010 7:38:00 AM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: