,<:r Energy$er.dces Report of Nondestructive Examination Visible, Solvent Removable Liquid Penetrant Examination Page 1 of4 Client:

Exelon (PO # 00000828, Release 00473)

Project No.:

Line/Drawing No.:

N/A (Exelon Relief Request 13R-19)

Weldlltem No:

901 348 Report No.: __

....::...90'0-1,;;3",,4-=;8--,;0.... 4 _

RVHP # 64 Date:

4-06-11 Part Shape / Size:

--'-P"'en"'e:.:t::.:ra::.:t"'io::n:...S"'4'---____ ____

Material Type:

AS SS CladdingiER 309UERNiCrFe-7A Time:

1300 NDE Procedure :

GOP-9.7 Rev.

13 Acceptance Standard:

Appendix A Sec 1.0 & 2.0 Surface Finish:

As Welded/ground Material Thickness:

Approx. O. 200" Stage of Fabrication:

Final PT of J-Weld/Pen 0.0. Overlay Joint Design:

J-Weld/Pen.OD Overlay TYPE II VISIBLE PENETRANT EXAMINATION, METHOD C SOLVENT REMOVABLE Cleaner:

SKC-S Penetrant:

SKL-SP1 Developer:

SKD-S2 Penetrant Application :

Brush Batch No:

10F16K Batch No:

09K02K Batch No:

09L05K Penetrant Removal:

0 1}' Wipe/Solvent Wipe Post-Type of Preclean Penetrant removal Developing Lighting Light B152FC Dry Time:

8Min.

Dwell Time:

15 Min.

Dry Time 7 Min.

Time:

17 Min.

Equipment Flashlight Intensity A150FC Part Cal. Due Light Meter Cal. Due Temperature:

75 OF Thermometer No:

OTC-135 Date:

9-25-11 No:

OLM-15 Dale:

9-15-1 1 IND.

Distance from A R NO:

Zero Dimensions TYPE C E C J 1

12:00 (J-Weld) 3/32" X 1/4" Linear X

2 12:00 (J-Weld) 1116" X 1116" Rounded X

Sketch: See pages 2 through 4 3

11:00 1/16" X 1/2 "

Linear X Comments: B= Before Testing A = After Testing 4

3:00 1/4" X 1/4" Rounded X Note # 1: The only relevant indications on the J-Weld surface overlay surface were 5

3:00 1/8" X 1/8" Rounded X

indications# 1 and 2 located @ 12:00.

Note # 2:There were a couple of areas located @ approximately 2:30that were 6

2:00 118" X y,-

Linear X considered cleaning issues and will need to be re-examined after repair.

7 2:00 1/8" X )1,"

Rounded X

8&9 5:00 & 6:00 1/16" X 3/16" Linear X

Weld / Item is o Acceptable IZI Rejectable Examiner: K~Q~

~4?~evel :

Date

-L~--"-=""'--'C;-

"""'f-~-=-H--":'------ Level: :tJ{: Date:

Reviewer:

Chent

_-,4/",0",6:..;/1,-,1_

Reviewer:

'1/0,,/((

~~~NII

___________ Date: