ML110670546

From kanterella
Jump to navigation Jump to search

Request for Additional Information Related to the License Amendment Request for Approval of Davis-Besse Cyber Security Plan
ML110670546
Person / Time
Site: Davis Besse 
Issue date: 03/10/2011
From: Michael Mahoney
Plant Licensing Branch III
To: Allen B
FirstEnergy Nuclear Operating Co
mahoney, m NRR/DORL/LPLIII-2 415-3867
References
TAC ME4341
Download: ML110670546 (6)


Text

..."R REGUt _

UNITED STATES "i)

NUCLEAR REGULATORY COMMISSION C>,)

'1'....

0

~

Cl WASHINGTON, D.C. 20555-0001 0

Iii March 10,2011

~

{;j

\\(',.

~

'l-"

~O

        • i<

Mr. Barry S. Allen Site Vice President FirstEnergy Nuclear Operating Company Davis-Besse Nuclear Power Station Mail Stop A-DB-3080 5501 North State Route 2 Oak Harbor, OH 43449-9760

SUBJECT:

DAVIS-BESSE NUCLEAR POWER STATION, UNIT NO.1 - REQUEST FOR ADDITIONAL INFORMATION RELATED TO THE LICENSE AMENDMENT REQUEST FOR APPROVAL OF DAVIS-BESSE CYBER SECURITY PLAN (TAC NO. ME4341)

Dear Mr. Allen:

By letter to the Nuclear Regulatory Commission (NRC) dated July 16, 2010 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML102020203), as supplemented by letters dated September 28, and November 23,2010 (ADAMS Accession Nos.

ML102740569 and ML103350171, respectively), and February 1,2011 (ADAMS Accession No. ML110390058), FirstEnergy Nuclear Operating Company (FENOC or the licensee), submitted a license amendment request for approval of the Davis-Besse Nuclear Power Station, Unit 1, Cyber Security Plan.

The NRC staff is reviewing your submittal and has determined that additional information is required to complete the review. The specific information requested is addressed in the enclosure to this letter. During a discussion with your staff on March 8, 2011, it was agreed that you would provide a response within 30 days from the date of this letter.

The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for NRC staff review and contribute toward the NRC's goal of efficient and effective use of NRC staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-3867.

Sinrei11JJIA ichael Mahoney, Project Ma Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-346

Enclosure:

Request for Additional Information cc w/encl: Distribution via Listserv

REQUEST FOR ADDITIONAL INFORMATION (RAI)

DAVIS-BESSE NUCLEAR POWER STATION, UNIT NO.1 DOCKET NO. 50-346 The Nuclear Regulatory Commission (NRC, the Commission) staff has reviewed the July 16, 2010 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML102020203) as supplemented by letters dated September 29, and November 29,2010 (ADAMS Accession Nos. ML192899417) and. ML103350211, respectively), and February 15, 2011 (ADAMS Accession No. ML110540414), FirstEnergy Nuclear Operating Company submittal regarding the request for approval of the Davis-Besse Nuclear Power Station (DBNPS),

Unit 1, Cyber Security Plan (CSP). The NRC staff has determined that the following information is needed in order to complete its review:

RAI 1: Records Retention Title 10 of the Code ofFederal Regulations (10 CFR), Paragraph 73.54(c)(2), requires licensees to design a cyber security program to ensure the capability to detect, respond to, and recover from cyber attacks. Furthermore, 10 CFR 73.54(e)(2)(i) requires licensees to maintain a CSP that describes how the licensee will maintain the capability for timely detection and response to cyber attacks. The ability for a licensee to detect and respond to cyber attacks requires accurate and complete records and is further supported by 10 CFR 73.54(h), which states that the licensee shall retain all records and supporting technical documentation required to satisfy the requirements of 10 CFR 73.54 as a record until the Commission terminates the license for which the records were developed and shall maintain superseded portions of these records for at least 3 years after the record is superseded, unless otherwise specified by the Commission.

The licensee's CSP, Section 4.13, states that Critical Digital Asset (CDA) audit records and audit data (e.g., operating system logs, network device logs) are retained for a period of time that is less than what is required by 10 CFR 73.54(h).

Explain the deviation from the 10 CFR 73.54(h) requirement to retain records and supporting technical documentation until the Commission terminates the license (or to maintain superseded portions of these records for at least 3 years) and how that meets the requirements of 10 CFR 73.54.

RAI 2: Implementation Schedule The regulation at 10 CFR 73.54, "Protection of digital computer and communication systems and networks," requires licensees to submit a CSP that satisfies the requirements of this section for Commission review and approval. Furthermore, each submittal must include a proposed implementation schedule and the implementation of the licensee's cyber security program must be consistent with the approved schedule. Paragraph 73.54(a) of 10 CFR requires licensees to provide high assurance that digital computer and communication systems and networks are adequately protected against cyber attacks, up to and including, the design basis threat.

The completion of several key intermediate milestones, (Items (a) through (g) below), would demonstrate progress toward meeting the requirements of 10 CFR 73.54. The NRC staffs ENCLOSURE

-2 expectation is that the key intermediate milestones will be completed in a timely manner, but no later than December 31,2012. The key CSP implementation milestones are as follows:

Establish, train and qualify Cyber Security Assessment Team, as described in Section 3.1.2, "Cyber Security Assessment Team," of the CSP is as follows:.

(a) Identify Critical Systems and CDAs, as described in Section 3.1.3, "Identification of Critical Digital Assets," of the CSP.

(b) Implement cyber security defense-in-depth architecture by installation of

[deterministic one-way] devices, as described in Section 4.3, "Defense-In-Depth Protective Strategies" of the CSP.

(c) Implement the management, operational and technical cyber security controls that address attacks promulgated by use of portable media, portable devices, and portable equipment as described in Appendix D, Section 1.19, "Access Control for Portable and Mobile Devices," of the Nuclear Energy Institute's (NEI) 08-09, Revision 6.

(d) Implement observation and identification of obvious cyber-related tampering to existing insider mitigation rounds as described in Appendix E, Section 4.3, "Personnel Performing Maintenance and Testing Activities," and Appendix E, Section 10.3, "Baseline Configuration," of NEI 08-09, Revision 6.

(e) Identify, document, and implement cyber security controls to physical security target set CDAs in accordance with Section 3.1.6, "Mitigation of Vulnerabilities and Application of Cyber Security Controls," of the CSP.

(f) Ongoing monitoring and assessment activities will commence for those target set CDAs whose security controls have been implemented, as described in Section 4.4, "Ongoing Monitoring and Assessment," of the CSP (g) Full implementation of the CSP for all safety, security, and emergency preparedness functions.

Provide a revised CSP implementation schedule that identifies the appropriate milestones, completion dates, supporting rationale, and level of detail to allow the NRC to evaluate the licensee's proposed schedule and associated milestone dates which include the final completion date. It is the NRC's intention to develop a license condition incorporating your revised CSP implementation schedule containing the key milestone dates.

RAI 3: Scope of Systems Paragraph 73.54(a) of 10 CFR requires licensees to provide high assurance that digital computer and communication systems and networks are adequately protected against cyber attacks, up to and including, the design basis threat as described in 10 CFR 73.1. In addition, 10 CFR 73.54(a)(1) states that the licensee shall protect digital computer and communication systems and networks associated with:

-3 (i)

Safety-related and important-to-safety functions; (H)

Security functions; (iii)

Emergency preparedness functions, including offsite communications; and (iv)

Support systems and equipment which, if compromised, would adversely impact safety, security, or emergency preparedness functions.

Subsequent to the issuance of the cyber security rule, the NRC stated that 10 CFR 73.54 should be interpreted to include structures, systems, and components (SSCs) in the balance of plant (BOP) that have a nexus to radiological health and safety (ADAMS) Accession No. ML103490344, dated November 19, 2010). The SSCs in the BOP are those that could directly or indirectly affect reactivity of a nuclear power plant and could result in an unplanned reactor shutdown or transient and are therefore, within the scope of important-to-safety functions described in 10 CFR 73.54(a)(1). Furthermore, the NRC issued a letter to NEI, dated January 5, 2011 (ADAMS Accession No. ML103550480), that provided licensees with additional guidance on one acceptable approach to comply with the Commission's policy determination.

Explain how the scoping of systems provided by the Davis-Besse CSP meets the requirements of 10 CFR 73.54 and the additional guidance provided by the NRC.

RAI 4: Definition of Cyber Incident Paragraph 73.54(e)(2) of 10 CFR requires that "the cyber security plan must include measures for incident response and recovery for cyber attacks." The definition of "incident" that the NRC finds acceptable, and as stated in Regulatory Guide 5.71, is as follows: "Occurrence, caused by either human action or natural phenomena that may cause harm and that may require action."

Furthermore, NEI 08-09, Revision 6, Appendix B (Glossary) guidance, defines cyber incident as "a digital-related adverse condition."

In the RAI submitted to the licensee on January 20,2011, the NRC asked the licensee to "please explain why Davis-Besse's CSP does not include a definition for 'cyber incident.'" The licensee's response to the NRC on this question, dated February 1, 2011, states:

"The DBNPS Cyber Security Plan does not include a definition for "cyber incident" because the phrase "cyber incident" is not used in the Cyber Security Plan. The phrase "cyber incident" would be defined within FENOC procedures. No revision to the DBNPS Cyber Security Plan is required."

The Davis-Besse CSP makes 17 references to NEI 08-09 Appendix E (Operational and Management Controls), describing the CSP's implementation of the controls listed in that document. Section 4.6 of the Davis-Besse CSP lists six Incident Response topics that, it notes, are discussed in NEI 08-09, Appendix E. NEI 08-09, Appendix E, discusses controls that describe an organization's responsibilities for addressing cyber incidents (e.g., Section 7, Attack

- 4 Mitigation and Incident Response), and the detailed descriptions use various forms of the term "cyber incident." For example, the term "cyber security incident" or "cyber incident" is used in the following manner:

  • Section 7.4 (Incident Handling), the control tasks the organization with "identification of what constitutes a cyber security incident"
  • Section 7.6 (Incident Response Assistance), the control states that the organization provides support personnel who offer advice and assistance to users "in response to and reporting of cyber security incidents;"

Section 9.2 (Awareness Training), the control states that the organization must establish, implement, and document "training to include practical exercises to simulate actual cyber incidents."

Because the CSP references controls that use the term "cyber incidents" in the areas of training, attack mitigation, incident response and recovery, and audit generation, as well as establishing a Computer Security Incident Response Team, it is clear that "cyber incident" is an integral component of the Davis-Besse cyber security program. Please provide a definition of "cyber incident" such that the NRC staff can determine if the associated actions fully comply with 1 0 CFR Section 73.54.

ML102740569 and ML103350171, respectively), and February 1, 2011 (ADAMS Accession No. ML110390058), FirstEnergy Nuclear Operating Company (FENOC or the licensee), submitted a license amendment request for approval of the Davis-Besse Nuclear Power Station, Unit 1, Cyber Security Plan.

The NRC staff is reviewing your submittal and has determined that additional information is required to complete the review. The specific information requested is addressed in the enclosure to this letter. During a discussion with your staff on March 8, 2011, it was agreed that you would provide a response within 30 days from the date of this letter.

The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for NRC staff review and contribute toward the NRC's goal of efficient and effective use of NRC staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-3867.

Docket No. 50-346

Enclosure:

Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:

PUBLIC LPL3-2 RlF RidsNrrPMDavis-Besse Resource RidsAcrsAcnw_MailCTR Resource RidsRgn3MailCenter Resource CErianger, NSIR ADAMS Accession No. ML110670546 Sincerely, IRA!

Michael Mahoney, Project Manager Plant Licensing Branch 111-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation RidsNrrDorlLpl3-2 Resource RidsNrrLASRohrer Resource RidsOgcRp Resource RidsNrrDorlDpr Resource PPederson, NSIR

  • By Memo Dated NRR-088 OFFICE LPL3-2IPM LPL3-2JLA NSIRIDSP/ISCPB LPL3-21BC LPL3-21PM NAME MMahoney SRohrer CErlanger RCarlson (NDiFrancesco for)

MMahoney 3/8/11 319111 2/18/11 & 3/4111

  • 3/10/11 3/

111