Emergency Response Data System
ML110200130
Person / Time
Site: San Onofre 
Issue date: 01/19/2011
From: St.Onge R
Southern California Edison Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML110200130 (4)


Text

I.~

SOUTHERN CALIFORNIA

~

EDISON An EDISON INTE RNATIONAL Company January 19, 2011 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington', DC 20555-0001 Richard J. St. Onge Director Nuclear Regulatory Affairs 10 CFR 50 Appendix E

Subject:

Docket No. 50-362 Emergency Response Data System San Onofre Nuclear Generating Station Unit 3

Dear Sir or Madam,

This letter is to inform the Nuclear Regulatory Commission (NRC) of changes that have been made to the Emergency Response Data System (EROS) at the San Onofre Nuclear Generating Station (SONGS) Unit 3. As required by 10CFR50 Appendix E, Section VI.3.a, any hardware and software changes that affect the transmitted data points identified in the EROS Data Point Library must be submitted to the NRC within 30 days after the changes are completed. Accordingly, the revised page to the EROS Data Point Library is provided in the Enclosure to this letter.

The affected data point identifier is the Unit 3 Volume Control Tank (T-077) level indication. The data point identifier changed from "L226" to "VCTLVL" on December 20, 2010.

This letter and the enclosure contain no new commitments.

Should you have any questions, please contact Ms. Linda T. Conklin at (949) 368-9443.

P.O. Box 128 San Clemente, CA 92674

Document Control Desk January 19, 2011

Enclosure:

Emergency Response Data System Changes For San Onofre Nuclear Generating Station Unit 3 cc:

E. E. Collins, Regional Administrator, NRC Region IV R. Hall, NRC Project Manager, San Onofre Units 2 and ~

J. P. Reynoso, NRC Senior Resident Inspector, Acting, San Onofre Units 2 and 3

ENCLOSURE Emergency Response Data System Changes For San Onofre Nuclear Generating Station Unit 3

ENGINEERING CHANGE NOTICE (ECN) (continuation)

PAGE..L of..L Doc No. _9""'0""'0=52=--__

Rev. _2_ ECN No.

D0043235 NECP ORDER. 800162499 Supersedes ECN/PIC D0030448 90052 Rev. 2 Page 113

~R DATA POINT LIBRARY REFERENCE FILE DATE:

REACTOR UNIT:

DATA FEEDER:

NRC ERUS PARAMETER; POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COHD DESC.:

MALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT REFERENCE; REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONs; ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT~OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL; INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR Df TRANSMITTERS:

LEVEL REFERENCE DESC.:

UNIQUE SYSTEM DESC.:

~

S03 S031 NOT LISTED

~

VOL. CONT. TK T077 LEVEL VOL. CONT. TK LEVEL A

utA o

100 TNKBOT 27 INCHES ABOVE TNKBOT p~

2 AVERAGE VOLUME conTROL TK T077 AT RADHASTE BLDG NfA NfA N/A DISPLAYS LAST GOOD READING y

DRY VOL

  • 4780 GALLONS