PSEG InternalU se Only Pagelof..1.
PSEGNUCLEAR L.L.C.
SALENUOPERATIONS Sl.OP-AB.CONT-OOOl(Q) - REV. 13 CONTAINMENT CLOSURE Biennial Review Performed: Yes No.-£ Change Package(s) and Affected Document Number(s) incorporated into this revision: None The following OTSC(s) were incorporated into this Revision: None REVISION
SUMMARY
The following changes were incorporated into this revision:
Revised Attachment 1 (Page 10 oflO) to reflect deletion of 11-15SW57 and 11-15SW65 due to installation ofDCP 80092249, CFCU Simplification - Fixed Resistance Control Scheme
[80092249-0350]
Revised Step 3.6.3 to indicate notifying the "LLRT Evolution Team" versus the "1ST Test Engineer(s)" to isolate any penetration that is breached to support LLRT. This change was incorporated due to organizational changes, and is considered to be editorial in nature.
IMPLEMENTATION REQIDREMENTS Effective Date:
lol "2'1IV':xJ~
DCP 80092249, CFCU Simplification - Fixed Resistance Control Scheme
CONTAINMENT CLOSURE S 1.oP-AB.CONT -OOOl(Q)
[C0330]
1.0 ENTRY CONDITIONS DATE: __ TIME: __ _
1.1 Any condition requiring Containment Closure to limit the potential release of radioactive material when the Plant is in Mode 5 or 6.
1.2 Entry from another abnormal operating procedure.
2.0 IMMEDIATE ACTIONS 2.1 None 3.0 SUBSEQUENT ACTIONS NOTE The OEH Door may be closed with the four corner bolts torqued to meet requirements that support closure prior to Core Boiling. When Maintenance is notified to secure the OEH door, clear communication is required" to ensure ALL bolts are to be secured to establish Containment Closure.
When operating in a reduced RCS inventory condition OR when the RCS is vented to the Containment atmosphere, Closure of the Containment Outage Equipment Hatch (OEH), Personnel Airlocks, and Containment Purge" Supply, Purge Exhaust and PressureNacuum Relief penetrations should be established prior to time to Core Boiling following; a Loss of RHR event (Refer to 80082938, Operation 0140).
During movement of irradiated fuel in the conta,inment, Containment Closure should be established within one hour fol'lowing a Fuel Har-ldling Accident.
When the initiating event is other than a loss of RHR Of a Fuel Handling Accident, Containment Closure should be established within four hours of the initiating event.
3.1 " IF AT ANY TIME, Radiation Protection determines the Containment is uninhabitable, THEN EVACUATE all personnel from Containment.
3.2 EVACUATE all non-essential personnel from Containment.
3.3 REQUEST Radiation Protection provide radiological coverage of Containment personnel.
3.4 REQUEST Containment Coordinator to provide personnel as required for Containment Closure.
3.5 INFORM all Containment Closure personnel that high temperature fluids and/or radioactive water and gases may be present near any RCS openings.
Salem 1 Page 1 of18 Rev. 13
S 1.oP-AB.CONT -OOOI(Q)
NOTES
.' This procedure provides the minimum actions necessary to satisfy Containment Closure.
Additional actions may be taken (e.g., closing lines from both inside and outside Containment) to ensure Containment Closure is satisfied.
Blind flanges may be used to satisfy valve closure.
3.6 DIRECT Containment Closure personnel to perform the following:
3.6.1 IF Containment Equipment Hatch is open, THEN:
A.
REMOVE obstructions from inner Containment Equipment Hatch, AND INSTALL umer Containment Equipment Hatch with a minimum of four bolts to eliminate air gaps.
OR B.
INSTALL Outage Equipment Hatch IA W SC.MD-FR.CAN-OOOl(Q)
AND ENSURE all penetrations are closed or Blind Flanged to eliminate air gaps.
C.
IF the Outage Equipment Hatch is installed with the OEH door opened OR latched closed with four comer bolts, THEN direct Maintenance to SECURE the door in the closed position with ALL ten bolts IA W SC.MD-FR.CAN-OOOI(Q) AND ENSURE all penetrations are closed or Blind Flanged to eliminate air gaps.
NOTE When the OEH door is in the process of being closed, one Airlock should remain open until notified by Maintenance that the OEH door is closed. The other Airlock should be closed.
Salem 1 3.6.2 IF any Personnel Airlock is open, THEN:
A.
REMOVE obstructions from Personnel Air Locks.
B.
CLOSE both inner AND outer Personnel Air Lock doors.
C.
ENSURE Personnel Air Lock door interlock is in service.
3.6.3 Notify the LLRT Evolution Team to ISOLATE any penetration that is breached to support LLRT.
Page 2 of18 Rev. 13
Sl.OP-AB.CONT -OOOI(Q) 3.7" IF Containment Closure is not established lAW Sl.OP-ST.CAN-0007(Q),
Refueling Operation - Containment Closure, THEN OBTAIN a blank copy.ofSl.OP-ST.CAN-0007(Q), Refueling Operations-Containment Closure for a listing of Containment Closure valves located inside AND outside Containment.
NOTES When the OEH door is in the process of being closed, one Airlock should remain open OR the Containment Purge should remain in service until notified by Maintenance that the OEH door is closed.
Containment Closure should be accomplished by closing the most readily available valves. located either inside or outside Containment. If valves on one side of Containment can NOT be closed to satisfy Containment Closure, then the valves on the opposite side for the associated penetration line shall be closed, as applicable.
Containment Purge may be restored after Containment airborne activity conditions have stabilized AND Radiation Protection release calculations are within acceptable limits.
3.8 IF Containment Closure is being established due to the potential release of radioactive material, THEN CLOSE Containment Ventilation penetrations as follows:
EITHER CLOSE the Outside Isolation valve and Outside Test valve for each line listed in the table below, OR CLOSE the Inside Isolation Valve and Inside Vent valve for associated line, OR ENSURE the Inside Isolation Blind Flange (1 VCF211 VCF3) is installed (as applicable), and Inside Vent valve for associated line is closed.
LINE OUTSIDE OUTSIDE INSIDE INSIDE ISOLATION TEST ISOLATION VENT PURGE SUPPLY lVCl'"
IVC917 lVCF2 lVC901 PURGE EXHAUST IVC4*
IVC916 IVCF3 lVC900 PRESS RELIEF IVC5
- IVC918 IVC6
- IVC902 Operated from the Control Room Salem 1 Page 3 of18 Rev. 13
S 1.0P-AB.CONT -OOOl(Q) 3.9 IF Containment Closure is not established lAW S 1.0P-ST.CAN-0007(Q),
THEN INITIATE Preliminary Containment Closure as follows:
3.9.1 REVIEW Components "Off Normal and Off-Normal Tagged" List(s),
AND any maintenance in progress on the following systems for effect on Containment Closure:
Control Air (CA)
Component Cooling (CC)
Safety Injection (SJ)
Chemical & Volume Control (CVC) 3.9.2 IF any CA, SW, CC, RHR, SJ, or CVC System penetration line that is not in service may communicate between Containment atmosphere and the outside environment, THEN CLOSE either the outside valves OR the inside valves listed in Attachment 1, Containment Penetrations, for that line.
3.9.3 DOCUMENT valves closed in blank copy ofSl.OP-ST.CAN-0007(Q),
Refueling Operations - Containment Closure.
3.10 ENSURE integrity of Containment Pressure Instrumentation (Elev. 78, Inner Penetration Area):
1PA-2386 1PA-2405 1PT-948A 1PT-948B 1PT-948C 1PT-948D 3.11 IF Fuel Transfer Canal is open to Containment with Reactor Cavity drained.,
THEN 'CLOSE Refueling Cavity from Fuel Handling Building as follows:
3.11.1 MOVE Fuel Transfer Cart to Containment.
3.11.2 CLOSE Fuel Transfer Tube Gate Valve.
3.12 EITHER CLOSE OR INSTALL a blind flange on ALL open electrical penetrations.
3.13 IF Preliminary Containment Closure is complete, THEN INITIATE completion ofSl.OP-ST.CAN-0007(Q), Refueling Operations-Containment Closure, to verify Containment Closure.
3.14 IF required for Containment cooling, THEN PLACE all available CFCUs with Service Water available in SLOW speed lAW Sl.OP-SO.CBV-0001(Q), Containment Ventilation Operation.
Salem 1 Page 4 of18 Rev. 13
S 1.oP-AB.CONT-OOOI(Q) 3.15 MONITOR Containment Radiation Monitors for increased activity:
3.15.1 IF Containment airborne activity increases, THEN OPERATE the Iodine Removal Units IA W Sl.OP-SO.CBV-OOOl(Q),
Conta1nment Ventilation Operation.
3.15.2 CONTINUE operation of Iodine Removal Units until Radiation Protection determines that airborne activity is within limits.
3.16 NOTIFY SM/CRS to refer to the Event Classification Guide and Technical Specifications.
3.17 IF any Containment line/penetration can NOT be closed off to isolate the Containment environment from the outside atmosphere, THEN CONTACT SM/CRS for further direction.
3.18 WHEN the following conditions are satisfied, Containment Closure is no longer required:
RCS temperature is stable or decreasing.
-+
RHR flow is stable.
EITHER RCS level is stable and greater than 97.5 ft, OR Refueling Cavity level is greater than 23 ft. above the Reactor Pressure Vessel flange.
Radiation Protection determines that Containment can be opened for access.
Technical Specification Action statements are exited.
3.19 WHEN Containment Closure is no longer required:
Salem 1 3.19.1 RESTORE Containment Ventilation to normal lineup IA W Sl.OP-SO.CBV-OOOl(Q), Containment Ventilation Operation.
3.19.2 RETURN Personnel Air Locks to positions as directed by SM/CRS.
3.19.3 RETURN inner Containment Equipment Hatch OR Outage Equipment Hatch to positions as directed by SM/CRS.
3.19.4 RESTORE access to Containment.
Page 5 ofl8 Rev.13
S 1.0P-AB.CONT-OOOI(Q) 4.0 COMPLETION AND REVIEW 4.1 UPDATE WCM to reflect valves that were closed IA W Sl.OP-ST.CAN-0007(Q).
4.2 COMPLETE Attachment 2, Sections 1.0 and 2.0, AND FORWARD this procedure to SM/CRS for review and approval.
4.3 SM/CRSPERFORM the following:
4.3.1 REVIEW this procedure with Attachments 1 and 2 for completeness and accuracy.
4.3.2 COMPLETE Attachment 2, Section 3.0.
4.3.3 FORWARD completed procedure to Operations 8tm.
END OF PROCEDURE Salem 1 Page 6 ofI8 Rev. 13
S 1.oP-AB.CONT -OOOI(Q)
ATTACHMENT 1 (page 1 of 10)
CONT~NTPENETRATIONS 1.0 Steam Generator Closure NOTE Satisfactory installation of manways and hand holes is accomplished by installing the component with a minimum of bolts. Gaskets are NOT required.
I LINE I OUTSIDE VALVES ** I INSIDE ISOLATION 11BF22
- 11BF57 AFIBF AND EITHER Steam Generator manways & handholes on 11AF11 *, 11AF21 *,
both primary and secondary sides.
11AF116, 11AF117, llAF1l8,llAF1l9, Steam Generator openings on piping systems 11AF124, 11AF126, 11AF129, including:
- llAF132, 11AF22 (ilv),
Main Feedwater System 11AF23 (cv), 11AF86 (ilv),
Chemical Feed/Wet Layup System llAF920 (cv), llAF921 (cv),
Steam Generator level columns OR 11AF23, 11AF129, 11AF132 12BF22
- 12BF57 AFIBF AND EITHER Steam Generator manways & handholes on 12AF11 *, 12AF21 *,
both primary and secondary sides.
12AF1l6, 12AF1l7, 12AF1l8, 12AF1l9, Steam Generator openings on piping systems 12AF122, 12AF123, including:
12AF124, 12AF125, 12AF126, 12AF134, Main Feedwater System 12AF22 (ilv), 12AF23 (cv)
Chemical Feed/Wet Layup System 12AF86 (ilv),
Steam Generator level columns OR 12AF23 Operated from the Control Room If stopcheck valve AF23 is CLOSED, then only the inboard vent and drain valves listed with it need to be closed for that AF line. Valve BF22 is required to be closed in either case.
(cv) = check valve; (ilv) = inline valve; (rv) = relief valve I
Salem 1 Page 7 of18 Rev. 13
S 1.oP-AB.coNT -OOOl(Q)
ATTACHMENT 1 (page 2 of10)
CONT~NTPENETRATIONS 1.0 Steam Generator Closure (Continued)
I LINE I
OUTSIDE VALVES **
I INSIDE ISOLATION AFIBF 13BF22
- 13BF57 AND EITHER Steam Generator manways & handholes on 13AF11 *, 13AF21 *,
both primary and secondary sides.
13AF1l6, 13AF1l7, 13AF118, 13AF1l9, Steam Generator openings on piping systems 13AF126, 13AF129, including:
13AF131, 13AF22 (ilv),
13AF23 (cv), 13AF86 (ilv);
Main Feedwater System 13AF921 (cv),
Chemical Feed/Wet Layup System OR Steam Generator level columns 13AF23 & 13AF129 AFIBF 14BF22
- 14BF57 AND EITHER Steam Generator manways & handholes on 14AFll *, 14AF21
- both primary and secondary sides.
14AF1l6, 14AF117 14AF119~ 14AF122, 14AF123, Steam Generator openings on piping systems 14AF124, 14AF126, 14AF22 including:
.(ilv), 14AF23 (cv), 14AF86 (ilv), 14AF920 (cv),
. Main Feedwater System OR Chemical FeedIW et Layup System 14AF23 Steam Generator level columns Operated from the Control Room if stop check valve AF23 is CLOSED, then only the inboard vent and drain valves listed with it need to be closed.
(cv) = check valve; (ilv) = inline valve; (rv) = relief valve I
Salem 1 Page 8 of18 Rev. 13
S l.oP-AB.CONT -OOOI(Q)
ATTACHMENT 1 (page 3 of 10)
CONT~NTPENETRATIONS 1.0 Steam Generator Closure (Continued)
I LINE I
OUTSIDE VALVES I
INSIDE VALVES GB llGB4 *, llGB47 llGB3 (ilv)
GB 12GB4 *, 12GB47 12GB3 (ilv)
GB 13GB4 *, 13GB47 13GB3 (ilv)
GB 14GB4 *, 14GB47 14GB3 (ilv)
MS llMS6, llMS10 *, llMS18 *, llMS45, llMS130, llMS146, llMS167 *,
IlMS2-5, IlMS199, IlMSll-15 (rv),
I1MS61, IlMS189 I1MS943 MS 12MS6, 12MSI0 *, 12MS18 *, 12MS130, 12MS146, 12MS167 *,
12MS2-5 12MS199, 12MSll-15 (rv),
12MS61, 12MS189 12MS943 MS 13MS6, 13MSlO *, 13MS18 *, 13MS45, 13MS130, 13MS146, 13MS167 *,
13MS2-5 13MS199, 13MSll-15 (rv),
13MS61, 13MS189 13MS943 MS 14MS6, 14MSI0 *, 14MS18 *, 14MS130, 14MS146, 14MS167 *,
14MS2-5 14MS199, 14MSll-15 (rv),
14MS61, 14MS189 14MS943 Operated from the Control Room This line cannot be closed from inside Containment. These valves will provide the best boundary if the line cannot be closed from outside Containment. ENSURE SM/CRS is notified if this line cannot be closed from outside Containment.
(cv) = check valve; (ilv) = inline valve; (rv) = relief valve I
Salem 1 Page 9 of18 Rev. 13
sl.oP-AB.CONT-OOOl(Q)
ATTACHMENT 1 (page 4 of 10)
CONT~NTPENETRATIONS 1.0 Steam Generator Closure (Continued)
I LINE I
OUTSIDE VALVES SS 118894
- SS 128894
- SS 138894
- SS 14SS94
- 2.0 Phase "A" Penetrations I
LINE I
OUTSIDE VALVES CA 11CA330
- CA 12CA330
- CC ICCI13 * & ICC215
- CVC ICV7
- CVC ICV69 * & ICV288
- eve ICV1l6 * & ICV335 Operated from the Control Room Operated from the Primary Sample Room I
INSIDE VALVES 118S93 **
128S93 **
138893 **
14SS93 **
I INSIDE VALVES 1CA930, 11CA542, llCA543, llCA360 (cv)
ICA931, 12CA542, 12CA543, 12CA360 (cv)
ICCllO, ICC179, ICCI80, ICC205, ICC274, ICC275, ICC278, ICCI09 (cv), ICCl12 (rv)
ICV3 *, ICV4 *, ICV5 *, ICV6 (rv)
ICV75 *, ICV77 *, ICV79 *, ICV272, ICV290, ICV74 (cv), ICVE24 ***
ICV1l4 *, ICV134 *, ICV284 (ilv) *, 1CV336, 1CV338, 1CV360, 11-14CV107, 11-14CVI08, ICV296 (cv), 1CVl15 (rv)
- ENSURE boundary of Heat Exchanger (lCVE24) on the Charging line side.
(cv) = check valve; (ilv) = inline valve; (rv) = relief valve I
I Salem 1 Page 10 of18 Rev. IS
ATTACHMENT 1 (page 5 of 10)
CONTAINMENT PENETRATIONS S 1.oP-AB.coNT -OOOl(Q) 2.0 Phase"N'Penetrations (Continued)
LINE OUTSIDE VALVES INSIDE VALVES DR IDR29 * & IDR915 IDR31, IDR50, IDR54, IDRI21, IDR30 (cv)
FP IFP147
- IFP275, IFP284, IFP285, IFP148 (cv)
NT INT25
- INT45, INT46, INT47, INT26 (cv)
NT INT32
- INT35 *, INT55, INT56, INT33 (rv),
INT34 (cv), 11-148J93
- PR IPR18
- IPR17
- SJ 18J53 *, ISJ60 *,
181123
- 18J212 SS.
18827
- 188103
- SS 18833
- 188104
- SS 18849
- 188107
- SS 18864
- 188110*
VC***
1VC8 * & IVC12
- 1VC7 * & IVC11
- Operated from the Control Room
- STOP APD lR11112 Sample Pump from Control Room Rack Area (Rack 109) prior to closing valves.
(cv) = check valve; (ilv) = inline valve; (rv) = relief valve Salem 1 Page 11 of18 Rev. 13
sl.oP-AB.CONT-0001(Q)
ATTACHMENT 1 (page 6 of 10)
CONT~NTPENETRATIONS 2.0 Phase "A" Penetrations (Continued)
I LINE I
OUTSIDE VALVES I
INSIDE VALVES WL IWL13
- IWLI2
- WL IWLI7
- IWLI6
- WL IWL97
- IWL96
- WL IWL99 & IWLI08
- IWL98
- WR IWR80
- IWR82 *~ IWR96, IWR97, IWR125, IWR126, 11-14WR62 *~ IWR8I (cv) 3.0 Phase "B" Penetrations I
LINE I
OUTSIDE VALVES I
INSIDE VALVES CC ICC1l8
- ICCI83, lCC184, ICC294, ICC307, ICC308, 11-14CCI20, lCC1l9 (cv)
CC ICC13I
- ICCI89, ICC283, ICC285, ICC287, ICC303, ICC305~ 11-14CC130, ICCI90 (ilv) *., ICC208 (cv)
CC lCC136
- ICC185, ICC242, lCC279, ICC280, ICC301, lCC302, Il-14CC127, lCC187 (ilv) *, lCC186 (cv), lCC135 (rv)
Operated from the Control Room (cv) = check valve; (ilv) = inline valve; (rv) = relief valve I
I Salem 1 Page 12 of18 Rev. 13
S 1.oP-AB.coNT -OOOl(Q)
ATTACHMENT 1 (page 7 of 10)
CONT~NTPENETRATIONS 4.0 Other Penetrations I
LINE !
OUTSIDE VALVES I
INSIDE VALVES CA lCA1714 (100' Airlock) lCA1718 (100' Airlock)
CA lCA1715 (130' Airlock) lCA1721 (130' Airlock)
CS lCS902 & lCS903 lCS900 & lCS901 CS llCS2 *, llCSI0, llCS36, llCS6, llCS44, llCS49, l1CS67, llCS46, llCS51, llCS52, l1CS48 (cv) 1 CS60, 11 CS4 (cv),
l1CS5 (rv)
-:CS 12CS2 *, 12CS 1 0, 12CS36, 12CS6, 12CS44, 12CS49, 12CS67, 12CS46, 12CS52, 12CS4 (cv),
12CS48 (cv) l2CS5 (rv)
CVC llCV98 & llCV318 llCV291, llCV293, llCV295, llCV99 (cv)
CVC 12CV98 12CV291, 12CV293, 12CV295, 12CV99 (cv)
CVC 13CV98 & 13CV318 13CV291, 13CV293, 13CV295, 13CV99 (cv)
CVC 14CV98 14CV291, 14CV293, 14CV295, 14CV99 (cv)
Operated from the Control Room (cv) = check valve; (ilv) = inline valve; (rv) = relief valve I
Salem 1 Page 13 of18 Rev. 13
S 1.0P-ARCONT -OOOI(Q)
ATTACHMENTl (page 8 oflO)
CONT~NTPENETRATIONS 4.0 Other Penetrations (Continued)
I LINE I
OUTSIDE VALVES I
INSIDE VALVES PRJ 1PR36, 1PR40, 1PR41, 1CS64, CSI 11-12CS5 (rv), 1CV309, CVCI 1CV365, 1CV43 (rv), 1SJ229, 1PR31, 1PR32, 1PR25 (cv) ***
SJI 1SJ293, 1SJ32 (rv), 11-12SJ39 RHR (rv), 11-12SJ48 (rv), 1 SJ167 (rv), 1RH3 (rv), 1RH25 (rv) 11-12RH19 *, 1RH20 *,
RHR 1RJI21, 1RH24, 1R1f41, 1RH26 *, 1RH47, 1RH25 (rv) 1R1f46 (cv), 1RH58, 1RH72 11-12RH4 *, 11-12R1f36, RHRISJ 1R1f33, 1RH81, 1R1f45 (cv),
1RH2 *, 1R1f49, lRH63, 1RH64, 1RH3 (rv) lSJ69 *, 1SJ160, 1SJ70 (cv)
SA 1SA591 (sf) & 1SA905 1SA120, 1SA121, 1SA272, 1SA119 (cv)
-SA 1 SA262 & 1 SA263 1SA264 SA 1 SA265 & 1 SA266 1SA267 SA 1 SA268 & 1 SA269 1SA270 SFIWL 1 SF22 & 1 SF73 1WL191 SFIWL lSF36 & 1SF76 1WL190 This line cannot be closed from inside Containment. These valves will provide the best boundary if the line cannot be closed from outside Containment. ENSURE SM/CRS is notified if this line cannot be closed from outside Containment.
(cv) = check valve; (ilv) = inline valve; (rv) = relief valve; (sf) = spectacle blind plate & flange I
Salem 1 Page 14 of18 Rev.l3
S 1.oP-AB.coNT -OOOl(Q)
ATTACHMENT 1 (page 9<ofl0)
CONTAINMENT PENETRATIONS 4.0 Other Penetrations (Continued)
I LINE I
OUTSIDE VALVES I
INSIDE VALVES SJ lSJ12 *, lSJ13 *, 181309 18J166 *, 18J149~ lSJ150 (cv),
18J19 *, 181311, 11-148J14, 11-148J15, 11-148J16 (ilv), 11-148J388 SJ 118J44 *, 118J126 SJ 128J44 *, 128J126 SJ 118J49
- 118J50 *, 118J154, 18J224, 118J43 (cv),
138J43 (cv) ***
SJ 128J49
- 128J50 *, 128J154, 18J218, 18J220, 128J43 (cv), 148J43 (cv) '***
SJ 118J40 *, 118J145, 18J216 18J63 *, 18J248, 13-148J136, 13-148J137, 13-148J138 ****
SJ 128J40 *, 18J194, 18J252, 18J159 *, 18J250, 11-128J136, 11-128J137, 128J145 11-128J138 ****
SJ 18J135
- 18J158 *, 18J214, 11-148J141, 11-148J142, 11-148J143 ****
Operated from the Control Room This line cannot be closed from inside Containment. ENSURE<8M/CR8 is notified if this line cannot be closed from outside Containment.
This line cannot be closed from inside Containment. These valves will provide the best boundary if the line cannot be closed from outside Containment. ENSURE 8M/CR8 is notified if this line cannot be closed from outside Containment.
- These valves are preset to prevent pump runout and should only be closed as a last resort effort to establish Containment Closure.
(cv) = check valve; (ilv) = inline valve; (rv) = relief valve
,~
'. 1 I
Salem 1 Page 15 of18 Rev. 13
ATTACHMENT 1 (page 10 oflO)
CONT~NTPENETRATIONS S 1.0P-AB.CONT -OOOI(Q) 4.0 Other Penetrations (continued)
I:
LINE 1
OUTSIDE VALVES r
INSIDE VALVES I
SS ISS901 N/A SW llSW58 *, ***
IISW62, IISW63, IISW64, IISW67, IISW69, IISW248, I1SW269 SW llSW72 *, ***
AND 11 CFCU Piping, Fan Cooler, and Motor Cooler are INTACT SW 12SW58 *, ***
12SW62, 12SW63, 12SW64, 12SW67, 12SW69, 12SW248, 12SW269 SW 12SW72 *, ***
AND 12 CFCU Piping, Fan Cooler, and Motor Cooler are INTACT SW 13SW58 *, ***
13SW62, 13SW63, 13SW64, 13SW67, 13SW69, 13SW248, 13SW269, 13SW280, SW 13SW72 *, ***
13 SW283 AND 13 CFCU Piping, Fan Cooler, and Motor Cooler are INTACT SW 14SW58 *, ***
14SW62, 14SW63, 14SW64, 14SW67, 14SW69, 14SW248, 14SW269, 14SW280, SW 14SW72 *, ***
14SW283 AND 14 CFCU Piping, Fan Cooler, and Motor Cooler are INTACT SW 15SW58 *,***
15SW62, 15SW63, 15SW64~ 15SW67, 15SW69, 15SW248, 15SW269 SW 15SW72 *, ***
AND 15 CFCU Piping, Fan Cooler, and Motor Cooler are INTACT VC IVCI0*
IVC9*
VC IVCI4*
1VC13*
Operated from the Control Room Closing these valves isolates the Containment Fan Coil Unit from its associated relief valve path eliminates the CFCUs overpressure protection. If these valves are closed then the associated CFCU should be drained to prevent damage to the CFCU coils in the event of a sudden temperature increase inside Containment.
Salem 1 Page 16 ofI8 Rev. 13
1.0 COMMENTS
ATTACHMENT 2 (page 1 of2)
~COMPLETION SIGN-OFF SHEET S 1 ~OP-AB.CONT -OOOI(Q)
(Include procedure deficiencies and corrective actions. Attach additional pages as necessary.)
Salem 1 Page 17 of18 Rev. 13
S 1.oP-AB.coNT -0001(Q)
2.0 SIGNATURES
Print ATTACHMENT 2 (page 2 of2)
-COMPLETION -SIGN-OFF SHEET Initials Signature 3.0 SMICRS FINAL REVIEW AND APPROVAL:
Date This procedure with Attachments 1 and 2 is reviewed for completeness and accuracy.
Entry conditions and all deficiencies, including corrective actions, are clearly recorded in the COMMENTS Section of this attachment.
Signature: __________________ _
Date:, ____ _
SM/CRS Salem 1 Page 18 of18 Rev. 13
CONTAINMENTCLOSUREIINTEGRITY TECHNICAL BASES DOCUMENT S 1.oP-AB.coNT -OOOl(Q)
1.0 REFERENCES
1.1 Technical Documents A.
Salem Generating Station Updated Final Safety Analysis Report:
- 1.
Section 6.2, Containment Systems B.
Salem Generating Station Technical Specifications Unit 1:
- 1.
3.6.1.1, Containment Integrity
- 2.
3.6.3.1, Containment Isolation Valves
- 3.
3.9.4, Containment Building Penetrations
- 4.
3.9.10, Water Level-Reactor Vesse!
C.
Configuration Baseline Documentation:
- 1.
DE-CB.CBV -0026(Q), Containment Building Ventilation System
- 2.
DE-CRCAN-0043(Q), Containment Internal Structures D.
Event Classification Guide:
- 1.
Section 6, Fission Product Boundary Failure
- 2.
Section 7, Radiological Releases / Occurrences
- 3.
Section 18, Technical Specification / Plant Status Changes 1.2 Procedures A.
S1.0P-AB.RHR-0001(Q), Loss ofRHR B.
Sl.OP-AB.RHR-0002(Q), Loss ofRHR at Reduced Inventory C.
S1.0P-SO.CBV-000l(Q), Containment Ventilation Operation D.
Sl.OP-SO.WG-0006(Q), Containment Purge to the Plant Vent E.
S 1.0P.;ST.CAN-0007(Q), Refueling Operations-Containment Isolation F.
SC.MD-FR.CAN-OOOl(Q), Outage Equipment Hatch Installation, Removal, and Seal Replacement 1.3 Industly Concerns Salem 1 A.
NUREG 1269, Loss of Residual Heat Removal System Diablo Canyon Unit 2 B.
NUREG 1410, Loss of Vital AC Power and the Residual Heat Removal System During Mid-Loop Operations atVogtle Unit Ion March 20, 1990 C.
INPO SOER 88-03, Losses of Residual Heat Removal with Reduced Reactor Vessel Level at PWRs, Recommendation 2.h, Instructions to Restore Containment Closure D.
INPO SOER 85-01, Reactor Cavity Seal Failure E.
INPO SER 86-21, Dropped Fuel Assembly at a PWR F.
NRC INFO 86-58, Dropped Fuel Assembly at Haddam Neck Plant G.
Westinghouse Owners Group Abnormal Response Guideline (WOG-ARG-l),
Loss ofRHR while Operating at Mid-Loop Conditions H.
NUMARC 91-06, Guidelines for fudustry Actions to Assess Shutdown Management.
Page 1 of6 Rev. 13
S 1.oP-AB.coNT-OOOl(Q) 1.4 Drawings 1.5 A.
205201, Reactor Coolant B.
205202, Steam Generator Feed & Condensate C.
205203,Main, Reheat & Turbine By-Pass Steam D.
205217, Compressed Air E.
205222, Fire Protection F.
205225, Steam Generator Drains & Blowdown G.
205228, Chemical & Vohune Control Operation H.
205231, Component Cooling I.
205232, Residual Heat Removal J.
205233, Spent Fuel Cooling K.
205234, Safety InJection L.
205235, Containment Spray M.
205236, Auxiliary Feedwater N.
205238, Containment Ventilation O.
205239, Waste Disposal Liquid P.
205242, Service Water Nuclear Area Q.
205244, Sampling R.
205246, Demineralized Water - Restricted Areas S.
205247, Control Air T.
207533, Unit 1 Safety Inj. Sys. Cont. spray Instrument Sch. - Control U.
222702, Unit 1 Penetration Area Electrical Power Penetration Diagram Other A.
B.
C.
D.
E.
F.
G.
S-C-SW-MEE-1236, Generic Letter GL96-06, Service Water System Modifications, Station Blackout Evaluation NLR-N89001, Dated January 6, 1989, Response to NRC Generic Letter 88-17 NLR-N890014, Dated January 27, 1989,90 Day Response to NRC Generic Letter 88-17 S-C-CA-CSE-0881, OEB UFSAR Change Notice 99-014 and Procedure SC.MD-FR.CA-0001(Q). Use during modes 5,6, and Undefined.
S-2-RC-MEE-1931, S-2-RC-MEE-1931, Containment Habitability following Loss of RHR Cooling with the RCS Drained to the Rx Flange 70047277 -0200, Clarify definition of Closure 1.6 Conformance Documents Salem 1 A.
C0330, NRC GL 88-17, Develop Procedures For Containment Closure B.
SOO-056, 50.59 Safety Evaluation, Nuclear Licensing Commitment Change to NL-N89001 to allow an open OEH door during mid-loop conditions when boiling will not occur Page 2 of6 Rev. 13
sl.oP-AB.CONT -OOOl(Q) 2.0 DISCUSSION 2.1 This procedure provides the instructions necessary for establishing Containment Closure.
Accidents with the potential of radiological releases to the environment require that the Containment be isolated from the general public. Operation in Mode 5 & 6 frequently requires Containment opening~ such as penetrations, hatches, and access ways. A method to provide rapid closure of Containment has been recognized following several industry events which resulted in actual or near releases to the environment.
It is. the intent of this discussion to provide the reasoning behind the logic and flowpath of the procedure. It is not intended to provide additional direction to the procedure.
The Nuclear Regulatory Commission has provided the following defInition:
CLOSED CONTAINMENT - A containment that provides at least one integral barrier to the release of radioactive material. Sufficient separation of the containment atmosphere from the outside environment is to be provided such that a barrier to the escape of radioactive material*is reasonably expected to remain in place following a core melt accident. This can be accomplished by providing reasonable assurance that the following conditions are met:
A.
The inner Equipment Hatch is installed and held in place by a sufficient number of bolts such that no air gaps exist in the sealing surface OR the Outage Equipment Hatch is installed using all bolts and the OEH door is capable of being closed within one hour during Mid-Loop operation IA WSC.MD-FR.CAN-0001(Q) OR OEH door is closed and secured with the four comer bolts torqued.
B.
A minimum of one door in each airlock is closed, and C.
Each penetration providing access from the containment atmosphere to the outside atmosphere shall be closed by a valve or a blind flange: Closure bya valve or blind
. flange used for containment isolation during power operation meets this specifIcation.
Closure by other valves or blind flanges may be used if they are similar in capability to those provided for containment isolation. These may be constructed of standard materials and may be justifIed on the basis of either normal analysis methods or reasonable engineering judgement.
2.2 Entry Conditions - Entry conditions are based on the requirement for establishing Containment Closure. The most signifIcant requirement is to prevent or stop radiological releases to the environment. This can be from several occurrences, such as a Fuel Handling incident in Containment, loss of Refueling Cavity level during Refueling, loss of RHR cooling with the potential for core boiling before restoration, and other similar casualties.
Each of these specifIc events have an Abnormal Operating Procedure associated with the casualty which will direct Containment Closure when prudent.
Salem 1 Page 3 of6 Rev. 13
S 1 ;OP-AB.CONT -OOOl(Q) 2.3 Immediate Actions - None 2.4 Subsequent Actions - A note is provided at Step 3.1 to inform the Operator that Containment Closure should be established prior to core boiling when operating in a redricedRCS inventory condition or With the ReS vented to the Contaimnent atmosphere, OR within one hour when movement of irradiated fuel in the containment, OR should be established within four hours when NOT operating in a reduced RCS inventory condition OR movement of irradiated fuel in the containment. This time limit is to establish Containment Closure prior to core dam.ag~. The time available between the loss of RHR cooling, core uncovery, and core damage varies depending on Plant conditions at the time of event initiation. For adverse conditions,the time to core damage could be as little as 30 minutes. For more favorable conditions, the time would exceed two hours.
In any event, Containment Closure should be established before core damage occurs (ref: Westinghouse Owners Group ARG-1).
Additional administrative.controls are in place to ensure Containment Closure is established within allowable times:
(1) Res inventory is not reduced until at least 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> after Unit shutdown to assure time to core uncovery is two hours or greater.
(2) Because both the Equipment Hatch and the Outage Equipment Hatch require four hours to install, installation is required prior to operating at reduced inventory (ref: PSE&G Response to GL 88-17, NLR-N89001 & NLR-N89014).
(3) If the Outage Equipment Hatch is installed, the OEH door can either be opened or closed IA W S 1.0P-ST.CAN-0007(Q) prior to and during operating at reduced inventory conditions or movement of irradiated fuel in containment. The Outage Equipment Hatch door must be capable of being switched from the Standby Position to the Closed Position in less than one hour during movement of irradiated fuel in containment OR prior to the time to core boil when at reduced inventory conditions. The OEH Door may be closed with the four comer bolts torqued to meet requirements to support closure prior to Core Boiling. When Containment Closure is required by this procedure ALL bolts are to be secured.
Therefore, this procedure establishes a time limit of either one hour, four hours, or prior to time to core boil based on existing Plant conditions.
Step 3.1 is a conditional statement directing immediate evacuation of all personnel in the Containment if at any time Radiation Protection determines the Containment is uninhabitable. A significant safety hazard may be present due to airborne activity, high temperatures, extreme humidity, and ionizing radiation. In all cases, personnel not involved in Containment Closure or in combating the initiating event are evacuated from the Containment (Step 3.2).
Salem 1 Page 4 of6 Rev. 13
S 1.oP-AB.CONT -OOOl(Q)
Step 3.3 requests Radiation Protection Department provide radiological coverage to Containment personnel. This is intended to reduce the possibility of inadvertent overexposure.
Step 3.4 requests the Containment Coordinator provide personnel to assist with Containment Closure.
Step 3.5 directs the Operator to inform all Containment Closure personnel of the potential for high temperature fluids and/or radioactive water/gases near RCS openings.
A note at Step 3.6 informs the Operator that this procedure provides the minimum actions necessary to satisfy Containment Closure. The note is intended to inform the Operator that additional actions may be taleen to ensure Containment Closure is satisfied, such as closing additional valves, closing both the inner and outer Personnel Airlocks, installing blind flanges, etc. The note also clarifies that blind flanges satisfy valve closure. Step 3.6 directs Containment Closure personnel to take the necessary actions to close the Equipment Hatch OR the Outage Equipment Hatch, and the Personnel Air Locks. Installation of the Equipment Hatch OR the Outage Equipment Hatch in the Closed Position with all air gaps eliminated has been deemed sufficient protection against radiological releases since the highest pressures postulated in Containment are less than the peale pressure expected in the Design Basis Accident (ref: Westinghouse Owners Group ARG-l).
Steps 3.7 direct the Operator to obtain a copy ofSl.OP-ST.CAN-0007(Q),Refueling Operations-Containment Closure. This surveillance identifies the valves outside and inside Containment that may need to be closed in order to.establish Containment Closure.
A note preceding Step 3.8 informs the Operator that Containment Closure should be accomplished by closing the most readily available valves located either inside or outside Containment. Ifvalves on one side of Containment can not be closed, then the corresponding valves on the opposite side of Containment for the associated line should be closed. Additionally, the note states that Containment Purge may be restored if Radiation Protection concurs and conditions requiring Containment Closure have stabilized.
The ability to automatically isolate Containment Ventilation due to radiological conditions is still available providing protection against uncontrolled airborne releases. Step 3.8 closes Containment Ventilation from the environment if a potential release ofradioactive material is present.
Step 3.9 directs initiation of Preliminary Containment Closure. The intent of preliminary closure is two-fold; first, to review Components "Off Normal" and "Off Normal Tagged" lists and any maintenance in progress for CA, SW, CC, RHR, SJ, & CVC Systems. Any line within these systems that may communicate between the Containment atmosphere and the outside environment is closed off to ensure Containment Closure. Second, to document all valves that are closed to satisfy Preliminary Containment Closure for each penetration line listed on Attachment 1. identifies each penetration line with the corresponding valves located outside and inside Containment.
While preliminary closure is in progress, the Operator is directed to ensure integrity of other lines penetrating Containment. Step 3.10 ensures integrity of Containment Pressure Instrumentation.
Step 3.12 ensures the integrity of electrical penetrations. Step 3.11 ensures the Fuel Transfer Canal is closed.
Salem 1 Page 5 of6 Rev. 13
S l.oP-AB.CONT -OOOl(Q)
After Preliminary Containment Closure has been performed, direction is given (Step 3.13) to verify Containment Closure by performing S 1.0P-ST.CAN-0007(Q). In many cases, only one valve, either inside or outside of Containment, is required to be closed. However, because* of outage activities, a single valve may not be available to satisfy closure. Therefore, it may be necessary to close multiple valves on the opposite side of the penetration to satisfy Closure. Sl:0P-ST.CAN..;0007(Q),Refueling Operations - Containment Closure, is performed to verify containment penetrations are isolated or operable. This procedure is performed to ensure the boundary of check valves, relief valves, and inline valves for the valve group that are being used satisfy Containment Closure. Boundary of check valves and other inline valves is checked to ensure a release path is not present through an open valve body.
Relief valves may be used to satisfy Containment Closure as they are normally closed, automatic-acting valves. Footnotes in the attachment provide additional information or direction to the Operator as necessary.
Step 3.14 directs the Operator to place all available Containment Fan Coil Units (CFCUs) with Service water available in slow speed if required for containment cooling, This is to minimize temperature and pressure increases in Containment even if cO],e boiling occurs. Operating CFCUs in slow speed is the analyzed configuration in the UFSAR. Operating CFCU s without Service Water cooling provides no additional cooling. Therefore, only CFCUs with Service Water available are placed in service. Step 3.15 places Containment Iodine Removal Units in service if airborne activity exceeds limits established by Radiation Protection.
The SMiCRS is directed to refer to the Event Classification Guide and Technical Specifications in Step 3.16.
Step 3.17 directs the Operator to cOFltact the SMiCRS if any ContaiE.ment penetration cannot be closed.
Step 3.18 lists the conditions that are to be satisfied before the procedure can be exited and Step 3.19 directs actions for the Operator to take when Containment Closure is no longer required.
The procedure is then exited in Section4.0'.
END OF DOCUMENT Salem 1 Page 6 of6 Rev. 13