ML110040834

From kanterella
Jump to navigation Jump to search
Bellefonte Units 3 & 4 Cola (Final Safety Analysis Report), Rev. 3 - FSAR Chapter 02 Figure 2.5-340
ML110040834
Person / Time
Site: Bellefonte  Tennessee Valley Authority icon.png
Issue date: 12/22/2010
From: Arent G
Tennessee Valley Authority
To:
Document Control Desk, Office of New Reactors
Spink T
References
BELLEFONTE.P02.NP, BELLEFONTE.P02.NP.3, TENNVALLEY, TENNVALLEY.SUBMISSION.6, +reviewedmmc1
Download: ML110040834 (1)


Text

Bellefonte Nuclear Plant, Units 3 & 4 COL Application Part 2, FSAR REACTOR UNIT #3 B B' Northeast S38°W Southwest (projected 45' southeast) (projected 38' northwest) (projected 5' northwest) (projected 45' southeast) (projected 8' northwest) (projected 65' northwest) (projected 5' southeast) (projected 65' northwest) (projected 25' northwest) (projected 38' northwest) (projected 35' northwest) (projected 42' southeast) (projected 42' northwest) (projected 13' southeast) (projected 8' southeast)

B-1086 B-1094 B-1088 B-1007 B-1021 B-1002 B-1005 B-1023 B-1003 B-1013 B-1006 B-1012 B-1019 B-1020 B-1011 B-1031 650 Plant grade 650 (el. 628.6')

610 Ground surface 610 Residual soil

? ? ? C

? ?

C UTA-54-E C D

C C D Top of rock C C D D D D D

35' 35' 35' 570 35' Excavation 35.4' Foundation 570 limit elevation 50' 50' 588.6' 60.1' 75.3' 530 71.2' 530 Elevation (feet )

75.3' Elevation (feet)

Middle Stones River Middle Stones River Middle Stones River 490 Unit D 120.5' 120.4' Unit D Unit D 490 120'

? D D

Middle Stones River E Middle Stones River E 450  ? Unit E E Middle Stones River  ? 450 Unit E E F

176' F Unit E

?

410 Middle Stones River Middle Stones River Middle Stones River 410

? Unit F F Unit F Unit F LSR

?

370 370 390 Lower Stones River 251' Lower Stones River Lower Stones River 390 40 feet Explanation Symbols Unit Descriptions 0

0 40 feet Observed water level (during drilling) Rock/soil interface, thin dashed line where Upper Stones River Limestone and argillaceous limestone Scale extrapolated, dotted where approximate Unit A Argillaceous and silty limestone*

No vertical exaggeration C Lithologic contact Unit B Limestone D UTA-54-E Resonant column and torsional shear testing Unit C Argillaceous and silty limestone*

Geologic contact, dashed where approximate Unit D Limestone Unit E Argillaceous and silty limestone*

Unit F Limestone Lower Stones River Limestone and argillaceous limestone Note: Lithology is interpolated between borings that lie within 10 feet of the section line.

Contacts in more distant borings are shown for information purposes.

The Stones River Group is comprised of Upper Stones River, Middle Stones River, *Argillaceous and silty limestone is described as Shale with and Lower Stones River. limestone interbeds in field descriptions on boring logs.

  • Argillaceous and silty limestone is described as Shale with limestone interbeds in field descriptions on boring logs.

FIGURE 2.5-340 BLN COL 2.5-6 Geotechnical Cross Section B-B' D-17D Rev 0