ML110030840

From kanterella
Jump to navigation Jump to search
E-mail from J. Tsao, NRC to E. Michel, NRC; Subject: Oconee Raw Service Water Pipe
ML110030840
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 08/21/2009
From: John Tsao
Office of Nuclear Reactor Regulation
To: Eric Michel
Division of Nuclear Materials Safety II
References
FOIA/PA-2011-0021
Download: ML110030840 (2)


Text

Stamm, Eric From:

Tsao, John

(-/d'-.k2 Sent:

Friday, August 21, 2009 8:46 AM To:

Michel, Eric Cc:

Franke, Mark; Chan, Terence; Nove, Carol; Hoffman, Keith; Gray, Harold

Subject:

RE: Oconee raw service water pipe

Eric, Recently an issue came up regarding a leaking buried pipe at Indian Point with affected our review of its license renewal application. The licensee for Indian Point talked about using guided wave UT also.

In a phone call with Region I recently, I think that Harold Gray or someone in Region I said that the guided wave UT was not effective at Oyster Creek. the UT did not identified the cracked location in the buried pipe because the crack was located at a pipe support and the pipe support masked the crack (or something to that effect).

Carol Nove in my branch studied guided wave UT as part of her review of Indian Point issue. If I remember correctly Carol said that if the guided wave is qualified, it can be useful. Carol is not in the office today so that I cannot verify the issue on the guided wave UT with her.

Keith-Hoffman has the lead on buried pipe in my branch. He is in the office today. his phone # is 301-415-1294. He told me that the guided wave technology has not been qualified or demonstrated. EPRI is doing a mockup to demonstrate the methodology. Please call Keith Hoffman on the latest development on the guided wave technology.

Thanks.

John From: Michel, Eric Sent: Friday, August 21, 2009 8:29 AM To: Tsao, John Cc: Franke, Mark

Subject:

RE: Oconee raw service water pipe

John, Yes, this is definitely safety related piping.

I talked with the residents and it sounds like Oconee has changed course a bit. They've made contact with GE and Structural Integrity to do some inspections of the pipe. Right now, their plan is to do a guided wave exam to perform the flaw characterization. From what I understand of guided wave, it's a fairly new technology. I'm assuming they'd try to use that data for the GL 90-05 evaluation. Guided wave isn't acknowledged by the Code as a volumetric technique, so I'm assuming we'd reject that idea. I'd appreciate any thoughts you've got on the topic.

Eric From: Tsao, John Sent: Friday, August 21, 2009 8:14 AM

"6: Mithel, Eric

Subject:

RE: Oconee raw service water pipe ok Thanks. my deputy division director was asking me the question about whether it is a safety related system John From: Michel, Eric Sent: Friday, August 21, 2009 8:12 AM To: Tsao, John

Subject:

RE: Oconee raw service water pipe I believe so, because it's a part of the safe shutdown facility. I'll double check.

From: Tsao, John Sent: Friday, August 21, 2009 7:47 AM To: Michel, Eric

Subject:

Oconee raw service water pipe

Eric, Is the Oconee raw service pipe safety system (the degraded portion of the pipe)?

Thanks.

John 2