ML103620020

From kanterella
Jump to navigation Jump to search
Wind Resource of Ohio Mean Annual Power Density at 100 Meters
ML103620020
Person / Time
Site: Davis Besse 
Issue date: 12/28/2010
From:
AWS Truewind
To:
NRC/SECY
SECY RAS
Shared Package
ML103620017 List:
References
License Renewal 2, RAS 19314, 50-346-LR
Download: ML103620020 (1)


Text

Lake Erie P e n n s y l v a n i a P e n n s y l v a n i a I n d i a n a I n d i a n a ONTARIO K e n t u c k y K e n t u c k y W e s t V i r g i n i a W e s t V i r g i n i a M i c h i g a n M i c h i g a n Ross Stark Wood Knox Pike Darke Scioto Licking Adams Gallia Allen Huron Butler Wayne Lorain Brown Clark Perry Logan Union Athens Trumbull Seneca Meigs Hardin Ashtabula Henry Noble Miami Franklin Mercer Preble Belmont Fulton Vinton Portage Fairfield Highland Erie Putnam Hancock Carroll Monroe Shelby Clinton Marion Muskingum Lucas Medina Richland Greene Holmes Warren Morgan Summit Madison Morrow Fayette Guernsey Washington Pickaway Coshocton Ashland Hocking Jackson Geauga Williams Clermont Harrison Delaware Paulding Lake Tuscarawas Lawrence Defiance Auglaize Hamilton Wyandot Cuyahoga Columbiana Jefferson Crawford Van Wert Mahoning Sandusky Champaign Montgomery Ottawa Akron Logan Bryan Canton Toledo Chester Vickery Lakewood McGuffey Hamilton Lexington Cleveland Lucasville Youngstown Conesville Cincinnati Mount Liberty 82°0'0"W 82°0'0"W 84°0'0"W 84°0'0"W 42°0'0"N 42°0'0"N 40°0'0"N 40°0'0"N 38°0'0"N 38°0'0"N 210000 210000 360000 360000 510000 510000 4200000 4200000 4350000 4350000 4500000 4500000 4650000 4650000 Power Density at 100 m Class W/m2 1- < 100 1+ 100 - 200 2 200 - 300 3 300 - 400 4 400 - 500 5 500 - 600 6 600 - 800 7 > 800 Features City Interstate Highway County Boundary Water Body Wind Resource of Ohio Wind Resource of Ohio Mean Annual Power Density at 100 Meters AWS Truewind, LCC Projection: Tranverse Mercator, UTM Zone 17 WGS84 Spatial Resolution of Wind Resource Data: 200m This map was created by AWS Truewind using the MesoMap system and historical weather data.

Although it is believed to represent an accurate overall picture of the wind energy resource, estimates at any location should be confirmed by measurement.

The transmission line information was obtained by AWS Truewind from the Global Energy Decisions Velocity Suite. AWS does not warrant the accuracy of the transmission line information.

0 10 20 30 40 5

Miles 0

10 20 30 40 5

Kilometers Generalized Transmission Line Category Under 100 kV 100 kV-161 kV 230 kV-287 kV 345 kV 500 kV 735 kV +

Step-Up DC Line