1 SeabrookNPEm Resource From:

Susco, Jeremy Sent:

Tuesday, October 19, 2010 9:23 PM To:

'Cliche, Richard'; 'Carley, Edward' Cc:

Wentzel, Michael; 'michael.okeefe@fpl.com'

Subject:

draft RAIs for Thursday's telecon Attachments:

Draft environmental RAIs.docx Follow Up Flag:

Follow up Flag Status:

Flagged Rick and Ed, Attached are the draft RAIs and the document needs list that we would like to discuss on Thursday.

Jeremy

Hearing Identifier:

Seabrook_License_Renewal_NonPublic Email Number:

286 Mail Envelope Properties (AF843158D8D87443918BD3AA953ABF7819C73F8096)

Subject:

draft RAIs for Thursday's telecon Sent Date:

10/19/2010 9:22:32 PM Received Date:

10/19/2010 9:22:00 PM From:

Susco, Jeremy Created By:

Jeremy.Susco@nrc.gov Recipients:

"Wentzel, Michael" <Michael.Wentzel@nrc.gov>

Tracking Status: None

"'michael.okeefe@fpl.com'" <michael.okeefe@fpl.com>

Tracking Status: None

"'Cliche, Richard'" <Richard.Cliche@fpl.com>

Tracking Status: None

"'Carley, Edward'" <Edward.Carley@fpl.com>

Tracking Status: None Post Office:

HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 136 10/19/2010 9:22:00 PM Draft environmental RAIs.docx 34664 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

Follow up

ENCLOSURE 1 Request for Additional Information For Seabrook Station License Renewal Environmental Review Meteorology and Air Quality

1. Please provide the annual air emission reports for Title V permitted sources (TV-OP-017 and GSP-EG-225), including fuel consumption per year, for the five most recent years.

Aquatic Ecology

1. In the Seabrook 2009 Environmental Monitoring in the Hampton-Seabrook Area: A Characterization of Environmental Conditions (NAI 2010), Table 4-1 Species Composition, Annual Totals, and Nine-Year Total of Finfish, and American Lobster Impinged at Seabrook Station from 1994 to 2009, provides impingement estimates from 1994 through 2009. Subnote a states that impingement data prior to October 1994 were underestimated. Please provide a brief explanation why these data were underestimated.
2. In NAI 2010, Table 4-6 Annual estimated numbers of fish eggs and larvae entrained (in millions) by the cooling water system at Seabrook Station from June 1990 through December 2009. provides entrainment estimates for several species of fish eggs and larvae. For egg entrainment estimates, several categories combine two or more species (e.g. Atlantic cod/haddock, cunner/yellowtail, hake spp., hake spp./fourbeard rocking) due to the similar appearance of the eggs and spawning seasons. Provide any supporting information available to estimate the percentage of eggs that belong to each species.
3. In NAI 2010, NextEra sampled in two main areas, the nearfield and farfield sites. The nearfield site is located near the intake and discharge structures, and the farfield site is located approximately 2-3 nautical miles from these structures. NextEra compares data from the two sites to determine whether plant operations have an impact on aquatic resources. Discuss the justification why the farfield site was selected. Describe any studies that were conducted to select the farfield site as a control site.
4. Please describe the cleaning and maintenance procedures for the intake and discharge structures, including the frequency of dredging, physical cleaning, and other maintenance procedures.
5. Please specify the flow rate at the intake structures.
6. Please provide any recent correspondence from Federal or State agencies regarding NAI 2010 or Seabrook Station, 2010 Environmental Monitoring Program Mid-Year Report and NextEras responses to those comments.
7. The Environmental Report states that NextEra stopped monitoring pelagic fish using gill nets because the sampling methods had detrimental impacts on aquatic resources.

Please provide documentation from National Marine Fisheries Service (NMFS) or other Federal or State agencies that suggested NextEra discontinue this monitoring program.

Human Health

1. The Environmental Report (ER), Section 3.1.3.3, Solid Radioactive Waste System, discusses how low-level radioactive waste is expected to be handled during the period of license renewal. However, as discussed in the ER, Seabrook Station cannot dispose of Class B and C low-level radioactive waste at the Barnwell, SC facility, as New Hampshire is not a part of the Atlantic Interstate Low-Level Radioactive Waste Management Compact. The ER states that Seabrook Station has sufficient capacity within the waste processing building for approximately seven years of storage for Class B and C waste. In addition to the storage capability, the ER discussed the use of a contractor to process and take title of the Class B and C waste for its disposal.

However, based on the information contained in the ER, the staff is unable to reach a conclusion regarding Seabrook Stations capacity to store and dispose of low-level radioactive waste over the term of license renewal. Please provide additional information about Seabrook Stations typical yearly low-level waste generation rates, processing methods, storage capability, and disposal options during the period of license renewal.

2. The ER, Section 3.1.3.4, Mixed Waste, discusses an outage event where a large volume (40 tons) of mixed waste was generated during a steam generator chemical cleaning process and that similar large volumes may be generated in the future. Is it reasonably foreseeable that there will be additional steam generator chemical cleanings that will require the disposal of similar large volumes of mixed waste during the term of license renewal? Also, the discussion on the generation of small volumes of mixed waste does not contain sufficient information for the staff to make an assessment of the mixed waste storage and disposal capabilities at the Seabrook Station. Please provide additional information about Seabrooks typical yearly mixed waste generation rates, processing methods, applicable permits, storage capacity, and disposal options during the period of license renewal.

Archaeological and Cultural Resources

1. Please provide any correspondence with the New Hampshire Division of Historical Resources or Native American tribes not included in the ER Hydrology and Water Quality
1. Please provide a summary of the last 12 months of analytical results of composite samples taken via the Radiation Monitor Control Station (located in the Auxiliary Building).
2. Has tritium been detected offsite above detection limits (based on quarterly sampling) in any of the new temporary monitoring wells (TW-1, TW-2, or TW-3) installed in the marsh south of the Auxiliary Building? If so, please identify the well(s), date(s) detected, and maximum observed results.

ENCLOSURE 2 References Requested for Docketing at the Seabrook Station Environmental Site Audit October 5-7, 2010 Meteorology and Air Quality Seabrook Station, Design Basis Document, Meteorological Monitoring System, DBD-MET-01, Revision 2, January 7, 2010.

FPL Company - New England Division, 345 kV Seabrook Transmission Substation SF6 Emissions Reduction Partnership for Electric Power Systems, Annual Report for 2005-2009.

NHDES, Stage I/II Gasoline Vapor Recovery System, Certificate of Compliance, March 20, 2008.

NHDES, Title V Operating Permit, TV-OP-017, Issued June 5, 2006.

NHDES, Issuance of General State Permit: GSP-EG-225, Issued July 2, 2008.

Aquatic Ecology ARCADIS et. al. (ARCADIS, Normandeau Associates Inc., Wayne C. Micheletti, Inc., and Harris Group, Inc.). 2008. Cooling Water Intake Structure information Document. Prepared for FPL Energy Seabrook, LLC. July 2008.

(Note that Appendix F is privileged and confidential. If the NextEra feels it is appropriate, you can request that this appendix be non-public by filling out an affidavit under 10 CFR 2.390.)

Florida Power and Light (FPL). 2006. Seabrook Station NPDES Permit NH0020338 Renewal Application. September 2006.

(Please include cover letter and Clean Water Act Section 316(a) and (b) certifications.)

NAI (Normandeau Associates, Inc.). 1988. Seabrook Environmental Studies, 1987. A Characterization of Baseline in the Hampton-Seabrook Area, 1975-1987. A preoperational study for Seabrook Station Technical Report XIX-II. Prepared for NH Yankee Division Public Service Company of New Hampshire. November 1988.

NAI (Normandeau Associates Inc.). 1991. Seabrook Station 1990 Environmental Studies in the Hampton - Seabrook Area: A Characterization of Environmental Conditions.

NAI (Normandeau Associates Inc.). 1994. Seabrook Station 1993 Environmental Studies in the Hampton - Seabrook Area: A Characterization of Environmental Conditions. Prepared for North Atlantic Energy Service Corporation.

NAI (Normandeau Associates Inc.). 1995. Seabrook Station 1994 Environmental Monitoring in the Hampton - Seabrook Area: A Characterization of Environmental Conditions. Prepared for North Atlantic Energy Service Corporation.

NAI (Normandeau Associates, Inc.). 1997. Seabrook Station 1996 Environmental Monitoring in the Hampton-Seabrook Area: A Characterization of Environmental Conditions.

NAI (Normandeau Associates Inc.). 2001. Seabrook Station Essential Fish Habitat Assessment. R-18900.009. Prepared for North Atlantic Energy Service Corporation.

NAI (Normandeau Associates, Inc.). 2008. Seabrook Station 2007 Environmental Monitoring in the Hampton-Seabrook Area: A Characterization of Environmental Conditions. Prepared for FPL Energy Seabrook Station.

NAI (Normandeau Associates, Inc.). 2010. Seabrook Station 2009 Environmental Monitoring in the Hampton-Seabrook Area: A Characterization of Environmental Conditions. Prepared for FPL Energy Seabrook Station.

NAI (Normandeau Associates, Inc.). 2010. Seabrook Station 2010 Environmental Monitoring Program Mid-Year Report.

NAI and ARCADIS. (Normandeau Associates, Inc. and ARCADIS). 2008. Seabrook Nuclear Power Station EPA 316(b) Phase II Rule Project, Revised Proposal for Information Collection.

Section 7.0. Prepared for FPL Energy Seabrook Station. June 2008.

NAI (Normandeau Associates, Inc.) and BBL (Blasland Bouck and Lee). 2006. Seabrook Nuclear Power Station EPA 316(b) Phase II Rule Project Proposal for Information Collection.

Prepared for FPL Energy Seabrook Station. Bedford, New Hampshire, Normandeau Associates. May 2006.

(Please also include associated letter to EPA dated May 4, 2006.)

NMFS (National Marine Fisheries Service). 2004. Letter From L. Allen, Office of Protected Resources to A. Legendre, FPL Energy Seabrook Station Regarding Withdrawal of Application for Incidental Take Authorization. May 7, 2004.

Padmanabhan M and Hecker GE. 1991. Comparative evaluation of hydraulic model and field thermal plume data Seabrook Nuclear Station. Alden Research Laboratory, Inc. Sponsored by New Hampshire Yankee Division of Public Service Company of New Hampshire.

Seabrook Station. 2010. Bivalve Larvae Entrainment Sampling. ZN1120.02, Rev.00, Chg. 03.

Regulatory Compliance Procedure.

Seabrook Station. 2010. Icthyoplankton Entrainment Sampling. ZN1120.01, Rev.01, Chg. 03.

Regulatory Compliance Procedure.

Please submit copies of the following figures of sufficient quality to allow for reproduction in the SEIS. Please remove any company logos from the figures or figure captions. Also, please submit electronic versions to michael.wentzel@nrc.gov and michelle.moser@nrc.gov.

From ARCADIS et. al. (ARCADIS, Normandeau Associates Inc., Wayne C. Micheletti, Inc., and Harris Group, Inc.). 2008. Cooling Water Intake Structure information Document. Prepared for FPL Energy Seabrook LLC. July 2008. Appendix A:

o Figure 3-13 Offshore Intake (Velocity Cap) at Seabrook Station o Figure 3-14 Profile of Intake Tunnel and Shafts at Seabrook Station o Figure 3-16 Seabrook Nuclear Power Station circulating water pumphouse Hydrology and Water Quality Seabrook, 2010, Environmental Reclamation of 32 Acres behind General Office Building, Rev.

1, March 23 Radiation Safety & Control Services, Inc. (RSCS), 2009a, Site Conceptual Ground Water Model for Seabrook Station, Rev. 01, TSD #09-019, June 9 Radiation Safety & Control Services, Inc. (RSCS), 2009b, Tritium Distribution and Ground Water Flow at Seabrook Station, Rev. 00, TSD #09-039, August 31 NextEra Energy Seabrook, LLC, 2009, Stormwater Pollution Prevention Plan for NextEra Energy Seabrook, Rev. 41, July 1 NHDES, 2010, NPDES Compliance Evaluation Inspection for NPDES Permit No. NH0020338, letter from P. Heirtzler, Wastewater Engineering Bureau, to A. Legendre, NextEra Energy Seabrook LLC, July 20 NHDES, 2010, NPDES Compliance Evaluation Inspection for NPDES Permit No. NH0020338, letter from P. Heirtzler, Wastewater Engineering Bureau, to A. Legendre, NextEra Energy Seabrook LLC, June 15 NextEra Energy Seabrook, 2010, Response to Letter of Deficiency - NPDES Compliance Evaluation Inspection, letter from M. OKeefe, Licensing Manager, to State of New Hampshire, Department of Environmental Services, July 15 Well completion data and elevation data for wells TW-1, TW-2, and TW-3 and the recent SW-series wells (circa 2009 and 2010)

Current illustrations of tritium data (plume) and groundwater elevation contours in surficial and bedrock aquifers, September 2010 (prepared by RSCS)

USEPA letter regarding timely and complete NPDES permit renewal application (circa 2006)

Discharge Monitoring Reports (DMRs) for the last 12 months, as submitted to the USEPA per NPDES Permit #NH0101303 Archaeological and Cultural Resources Seabrook Station Program Manual, Environmental Compliance Manual, Rev. 41 (NAEC)

Cultural Resources Protection Plan (Draft) and Final, when available Cultural Resources Management Plan, Seabrook Nuclear Power Plant, Seabrook and Hampton Falls, New Hampshire, May 2010 by Brian Valimont, New England Archaeology Co., LLC (Please submit via separate letter, as this document is to remain non-public per 36 CFR 800.11(c).

Meteorology and Air Quality Letter of Deficiency for the Title V air permit issued by New Hampshire Department of Environmental Services in 2010 and any subsequent related correspondence Socioeconomics Visitor center attendance for the last three years Emergency preparedness fees for the last three years Mill rates and education takes for the last three years Tax statement for appraisal value of Seabrook Station for the last three years