Independent Spent Fuel Storage Installation - Changes to the Emergency Response Plan Implementing Procedure ERPIP-730, Radiation Protection Hospital Assistance, Revision 00105
ML103260117
Person / Time
Site: Calvert Cliffs  
Issue date: 11/18/2010
From: Fick M
Calvert Cliffs 3 Nuclear Project, Constellation Energy Group, EDF Group
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
ERPIP 730, Rev 00105
Download: ML103260117 (12)


Text

Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 CENG a joint venture of 0Costellation

  • '~eDF Energy 0 Q CALVERT CLIFFS NUCLEAR POWER PLANT November 18, 2010 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos. I & 2; Docket Nos. 50-317 & 50-318 Independent Spent Fuel Storage Installation Docket No. 72-8 Changes to the Emergency Response Plan Implementing Procedures As required by 10 CFR 50.54(q), 10 CFR Part 50 Appendix E.V, and 10 CFR 72.44(f), changes to the Emergency Response Plan Implementing Procedures are enclosed. These changes do not decrease the effectiveness of the Emergency Response Plan.

Should you have questions regarding this matter, please contact Mr. Douglas E. Lauver at (410) 495-5219 or Mr. Michael J. Fick at (410) 495-5216.

Very truly yours, for Michael J. Fick Director - Emergency Preparedness MJF/PSF/bjd

Enclosures:

ERPIP 730, Revision 00105 cc:

W. M. Dean, NRC Resident Inspector, NRC V. Ordaz, NRC (ISFSI, Spent Fuel Project Office)

(Without Enclosures)

D. V. Pickett, NRC S. Gray, DNR

  • Constellati on Energ Calvert Cliffs Nuclear Power Plant TECHNICAL PROCEDURE ERPIP-730 RADIATION PROTECTION HOSPITAL ASSISTANCE Revision 00105 Safety Related REFERENCE USE Applicable To:

Calvert Cliffs Nuclear Power Plant Approval Authority:

Plant General Manager

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 2 of 11

SUMMARY

OF ALTERATIONS Revision Change Summary of Revision or Change Procedure upgraded to meet the format and content requirements of the Technical Procedures Writer's Manual. Revision bars have not been used to identify these changes.

Changed all TLD references to DLR (Dosimeter of Legal Record) throughout the procedure. Calvert Cliffs will be going to vendor processing and will no longer be using TLDs.

Changed ERO positional titles to support closure of AF200200004, Nos. 002-008 to ensure ERO position titles are consistent among Emergency Preparedness program plans and procedures.

.05-026 Editorial correction to change title of procedure from Health Physicist Hospital Assistance to Health Physics Hospital Assistance (change bars not used to identify in procedure), and change references to Health Physics Technician to Health Physics personnel.

0103 Editorial correction to perform the following:

Change, where necessary, CEG Medical Director to CE Medical Staff notification.

Change, where necessary, CEG physician to CE physician/Medical Director Occupational Health &

Environmental Management.

Add "Specific Hospital Plan" to step 6.3.A.1.a.

Change "New Hospital" to "Emergency Room Entrance" on, page 1 of 2.

Change Health Physics to Radiation Protection due to Radiation Protection reorganization.

Change references from PR-3-100 (where applicable) to CNG-PR-3.01-1000 to align Calvert Cliffs procedures with Fleet procedures.

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 3 of 11

SUMMARY

OF ALTERATIONS Revision Change Summary of Revision or Change 04 Entire Procedure - Previous change bars have been removed to prevent human error.

Entire Procedure - Changed "CEG" and "CE" to "CENG" 1.0 - Changed "attending an" to "supervising the care to an" 6.1.1 - Bullet 3 - Changed "Barriers" to "Postings and Barricades" (PCR-10-03273) 6.1.5 -Added "Electronic Personal Dosimeter (EPD)" (PCR 03273) 9.0 - Deleted the steps in this section because there are no records generated from this procedure. - Updated the map for the Radiological Emergency Area at Calvert Memorial Hospital. (PCR-1 0-03273) 05 Updated map for Calvert Memorial Hospital

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 4 of 11 TABLE OF CONTENTS SECTION TITLE PAGE 1.0 P U R P O S E...................................................................................................................................

5 2.0 APPLICABILITY/SCOPE............................................................................................................

5 2.1.

Applicability............................................................................................................

5 2.2.

S co p e.............................................................................................................................

5

3.0 REFERENCES

AND DEFINITIONS......................................................................................

5 3.1.

Developmental References.........................................................................................

5 3.2.

Performance References.........................................

6 3.3.

Definitions...............................................................................................................

6 4.0 PREREQUISITES 6

4.1.

Training and Qualifications........................................................................................

6 4.2.

Initial Conditions........................................................................................................

6 5.0 PRECAUTIONS.................................................................................................................

6 6.0 PERFORMANCE 7

6.1.

A ctivatio n...................................................

7 6.2.

Radiation Emergency Area Personnel and Equipment Control

................. 8 6.3.

CENG Medical Staff Notification.................................................................................

8 6.4.

Patient Removal From Radiological Emergency Area (if applicable)..........................

8 6.5.

Radiation Exposure Follow-Up Activities to Consider (as warranted).........................

9 6.6.

Arrange for Shipment of Radioactive Materials.........................................................

9 7.0 POST-PERFORMANCE ACTIVITIES....................................................................................

9 8.0 B A S E S.....................................................................................................................................

9 9.0 R E C O R D S.................................................................................................................................

9 ATTACHMENT 1, Calvert Memorial Hospital Radiation Emergency Area.......................................

10

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 5 of 11 1.0 PURPOSE To provide emergency response instructions to the Radiation Protection Personnel attending an injured contaminated person.

2.0 APPLICABILITYISCOPE 2.1.

Applicability This procedure provides instructions for the Radiation Protection -Personnel supervising the care to an injured contaminated person transferred from Calvert Cliffs Nuclear Power Plant to Calvert Memorial Hospital.

2.2.

Scope 2.2.1.

CENG personnel are to assist the hospital staff with respect to radiological and contamination hazards. It is appropriate to make recommendations to reduce exposure and contamination spread as necessary. However, CENG personnel are not to interfere with medical treatment of the injured person.

2.2.2.

This procedure is used for all cases of injured contaminated personnel taken to Calvert Memorial Hospital from Calvert Cliffs Nuclear Power Plant.

3.0 REFERENCES

AND DEFINITIONS 3.1.

Developmental References 3.1.1.

NUREG 0654, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants 3.1.2.

10 CFR 20, Standard for Protection Against Radiation 3.1.3.

10 CFR 50.47, Emergency Plans 3.1.4.

10 CFR 50 Appendix E to Part 50, Emergency Planning and Preparedness for Production and Utilization Facilities 3.1.5.

Calvert Cliffs Nuclear Power Plant Emergency Response Plan 3.1.6.

PR--1101, Preparation and Control of Calvert Cliffs Technical Procedures 3.1.7.

PR--I103, Use of Procedures 3.1.8.

Technical Procedures Writer's Manual

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 6 of 11 3.2.

Performance References None 3.3.

Definitions None 4.0 PREREQUISITES 4.1.

Training and Qualifications 4.1.1.

Personnel performing this procedure shall be qualified on the tasks or activities contained in this procedure.

4.2.

Initial Conditions 4.2.1.

Injured contaminated person has been transferred to Calvert Memorial Hospital.

5.0 PRECAUTIONS 5.1.

One concern of attending physicians is the use of blocking agents (for example, potassium iodide (KI) for iodine and Ethylenediaminetetraacidic Acid (EDTA)) for cesium. As guidance, Radiation Protection Personnel should recommend the following:

The consideration of a blocking agent if the actual or potential exposure to a radionuclide is in excess of 20 % Annual Limit on Intake (ALl).

The administration of a blocking agent if the actual or potential exposure is in excess of 50 % ALl.

ALl for I-131 is 50 microcuries S

,*ALI for Cs-1 37 is 200 microcuries 0

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 7 of 11 6.0 PERFORMANCE 6.1.

Activation NOTE Order of actions is not mandatory.

6.1.1.

CHECK Radiation Emergency Area setup (see Attachment 1, Calvert Memorial Hospital Radiation Emergency Area) for the following:

Step-off pads Friskers Posting and Barricades erected, as required 6.1.2.

TELL ambulance personnel to stay with the ambulance at the hospital until they are surveyed and released.

6.1.3.

BRIEF the hospital staff on the contamination status.

6.1.4.

IF entering Radiation Emergency Area, THEN DON anti-Cs (hospital supplied) and CHECK the attending hospital staff for proper protective clothing and correct use of protective clothing.

6.1.5.

CHECK hospital staff for proper dosimetry AND proper Use of Dosimeter of Legal Records (DLRs), Direct Reading Dosimeters (DRDs) or Electronic Personal Dosimeters (EPD).

6.1.6.

CHECK Radiation Emergency Area for suitable number of contaminated waste containers.

6.1.7.

CONSULT with attending physician.

NOTE CENG personnel may make recommendations regarding contamination and radiological hazards. However, the attending physician makes all treatment decisions.

6.1.8.

ANSWER questions posed by attending physician.

6.1.9.

ASSIST, as required.

6.1.10.

MONITOR tissue specimens.

6.1.11.

LABEL and SAVE specimens for radiation evaluation.

6.1.12.

ASSIST with decon; as requested.

6.1.13.

MONITOR the patient periodically to access decon effectiveness.

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 8 of 11 6.2.

Radiation Emergency Area Personnel and Equipment Control 6.2.1.

CHECK that protective coverings over equipment are used as appropriate to prevent contamination spread.

6.2.2.

OVERSEE the movement activities of patients and hospital staff to reduce the spread of contamination.

6.3.

CENG Medical Staff Notification 6.3.1.

IF patient is verified contaminated OR Calvert Memorial Hospital physician wishes to consult with a CENG physician/Medical Director Occupational Health & Environmental Management, THEN:

1.

ENSURE Plant Health Physicist establishes communication with the CENG Manager-Safety and Medical Services Department.

a.

SEE the Facility Phone Number list, Company phone directory, or Specific Hospital Plan.

2.

CONDUCT informal briefing(s) with Calvert Memorial Hospital staff and CENG physician/Medical Director Occupational Health &

Environmental Management, as necessary, to include the following:

Current event situation (that is, radiological conditions)

Follow-up tasks that may need to be performed 6.4.

Patient Removal From Radiological Emergency Area (if applicable) 6.4.1.

COLLECT all personnel dosimetry for DLR processing at CCNPP.

6.4.2.

EVALUATE and REPORT personnel dose.

6.4.3.

COLLECT protective clothing, contaminated waste, and so forth, for return to Calvert Cliffs.

6.4.4.

SURVEY equipment and property and DECON as need.

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 9 of 11 6.5.

Radiation Exposure Follow-Up Activities to Consider (as warranted)

NOTE The Plant Health Physicist may waive the following actions if inhalation or ingestion of radioactivity by the Calvert Memorial Hospital staff is unlikely or insignificant. Whole body counting maybe offered as a courtesy or on request.

6.5.1.

ARRANGE whole body count for patient AND all hospital personnel who attended patient.

6.5.2.

IF available, THEN EVALUATE exposure results.

6.5.3.

IF deemed appropriate, THEN ARRANGE for in-vitro samples to be taken.

6.5.4.

IF available, THEN EVALUATE sample results.

6.6.

Arrange for Shipment of Radioactive Materials 6.6.1.

COMPLETE shipping papers for transport of radioactive material to CCNPP according to Department of Transportation (DOT) regulations.

6.6.2.

CONSULT with Radiation Protection Supervision (Support) for guidance.

6.6.3.

PERFORM radiological surveys of the Radiation Emergency Area and adjacent areas.

6.6.4.

DOCUMENT radiological cleanliness before returning facilities to unrestricted use by Calvert Memorial Hospital staff.

6.6.5.

FORWARD all records to Director-Emergency Preparedness at event termination.

7.0 POST-PERFORMANCE ACTIVITIES None 8.0 BASES None 9.0 RECORDS None

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 10 of 11 Page 1 of 2 ATTACHMENT 1, Calvert Memorial Hospital Radiation Emergency Area Enter Here

RADIATION PROTECTION HOSPITAL ASSISTANCE ERPIP-730 Revision 00105 Page 11 of 1i Page 2 of 2 ATTACHMENT 1, Calvert Memorial Hospital Radiation Emergency Area (CONTINUED)

Radiological Emergency Area Floor Plan Located in Calvert Memorial Hospital Emergency Department RADIOLOGICAL EMERGENCY AREA (REA)

SJAN.CLOSET D_ L E O DECO0

,,o,

STORAGE u z*

CONTROLLED Shower Head ImAREA 015 DECONTAMINATI)N 15AROOM