Text

From:

William D Bartron [william.d.bartron@dom.com]

Sent:

Friday, October 22, 2010 7:46 AM To:

Sanders, Carleen

Subject:

RE: Clarification for Relief Request RR-04-06

Carleen, You are correct, per discussion with the Millstone Engineering department this is a typo.

Section 3 of the request should state the Applicable Code Requirement is from the 2004 Edition (No Addenda) of the ASME Code Section XI.

If you have any questions, please contact me.

Bill William D. Bartron Station Licensing Supervisor Millstone Power Station Dominion Nuclear Connecticut, Inc.

860-444-4301 From: Sanders, Carleen [1]

Sent: Thursday, October 21, 2010 4:03 PM To: William D Bartron (Generation - 4)

Subject:

FW: Clarification for Relief Request RR-04-06 Afternoon, As a follow-up to our earlier phone conversation, can you please verify the following:

In the Dominion Nuclear Connecticut, Inc. (DNC), submittal for Relief Request RR-04-06 for Use of PDI Qualified Procedures, Personnel and Equipment for Non-Appendix VIII RPV Shell-to-Flange Weld, DNC states in Section 2 that the Applicable Code Edition and Addenda is the 2004 Edition (No Addenda) of the ASME Code,Section XI. However, in Section 3 of the request, DNC states that the Applicable Code Requirement is from the 2001 Edition (No Addenda) of the ASME Code Section XI. Please verify that this date in Section 3 is a typo, and it should be 2004.

Thank you, Carleen Sanders Millstone Project Manager 301-415-1603

CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and/or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.

E-mail Properties Mail Envelope Properties (90D7BEDC8151CB4A98D4952A4C3B3A97025612414A)

Subject:

RE: Clarification for Relief Request RR-04-06 Sent Date: 10/22/2010 7:45:50 AM Received Date: 10/22/2010 7:45:50 AM From: William D Bartron Created By: william.d.bartron@dom.com Recipients:

Carleen.Sanders@nrc.gov (Sanders, Carleen)

Tracking Status: None Post Office:

DOM-MBX06.mbu.ad.dominionnet.com Files Size Date & Time MESSAGE 17237 10/22/2010 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: