TENNESSEE VALLEY AUTHORITY EXAMINATION
SUMMARY
AND RESOLUTION SHEET REPORT NUMBER:
K-PoSo8
./
PROJECT: WBN UNIT:
2 CYCLE 00 COMPONENT In: SIF-D193-03 EXAMINATION METHOD SYSTEM: SIS lSI DWG NO: ISI-2063-W-ll MT D
PT D
~
VT D
CONFIGURATION:
CATEGOR PROCEDURE:N-UT- ~4 REV I
TC: AII A-VAL TO P B-J EXAMINER:
EXAMINER:
EXAMINER:
EXAMINER:
1PS£.- H/~ Ip n)1" ~
- )
LEVEL:
- r Total coverage calculated to be approximately
'70
/110..tKam/l1alhl'1 SCan 3
dld-L b PCLlve. 7eome--!rj.
/flo reccJrCJa.lJl-e... /;'d;cabbrzS' t2Z,>,crl/cd RESOLUTION~'
~VIEWED~,
~
- du Q;.jo'Q"~"if=
{;:;~------------
LEVEL LJ,.-DATE: tJG* 21*oCj LEVEL:1J..(..., DATE:
- d 4 -
ACCESS: FORMS DATABASE R-10/04/01 ANII:
TENNESSEE VALLEY AUTHORITY DIGITAL ULTRASONIC CALIBRATION DATA SHEET REPORT NUMBER 1<* P()Sc>8 PROJECT WBN UNIT/CYCLE 2/00 CALIBRATION DATE: 06 '~~-d1 CALIBRATION BLOCK NO. W883 TEMP: 77./ OF PROCEDURE: N-UT- '4 REV:
II TC: tV/A SIMULATOR BLOCK: RoMP~5 TRANSDUCER
'-'----'-'=.:..::..~<-------
MANUFAC KB,4 MODEL:
CoA1,e G THERMOMETER SIN: 1:3905"4 DUE DATE: 08~1;l,09 l?
/
COUPLANT: tI#r....~</ 1/.
BATCH:
O'~~$"'
- ELEMENTS:
I SHAPE:
l'Ot1"~
ANGLE VERIFICATION ~~~~:::~
SIN 011. v4c SIZE:
.,15"""0 FREQ: ::l~? MH2 BLOCK TYPE,..foMeiS SIN:
93 -S"7:l4=
CONTOUR:
FOCUS',4/d NOMINAL ANGLE:
~')
ACTUAL ANGLE 4-5"0 INSTRUMENT ------....-t CABLE TYPE8GI74-LENGTH-7,7* CJ
- CNT:~ MANUFACTURER: KA...-r~e,< DUE DATE:"8./8~C'9 MODE:
~ SHEAR D LONG D RL MODEL NO.:
t15A/ '0 SIN:
c.f7~88
/
20 1---+---+--+-+--+--+---+-+----+----1 60 t---+---+---t-+---+---+--t-+---+---1 DAC REFLECTOR REFERENCE MEMORY SCAN DIRECT.
NTC SDH SENSITIVITY NUMBER A
AXIAL D
D IJJ n-dB UA M
CIRe.
~
D a8.~ dB
~fi~3,"'-SS PRANGE:
1.;;'00 inches *FREQ:
~.;/S-MHz L
PROBE DELA 1':3()" msec *RECTIFY: r,.IIWAY-I VELOCITY 0, I;.7/
msec DUAL 0
ON 18 OFF T
DISP DELAY:
O.OOD
- REJECT:
~
U
- ENERGY:
/1-.,,,
- DISP. START: :r"P D
- DAMPING: /,k ohms E
- PRRlPRF: tI~ #~ ~
DET: D Peak
~ Flank o
ANGLE-15:
deg TCG:
D ON
~ OFF DISPLAY WIDTH I. ~C>O inches ZERO:
IY'df msec
- PULSER:
5'~4/~
/.,li 40 I---+---+--+~.,~#"..;y
,-+--+--+-------1----1 80 1---+---+--+-+--+--....--+-+-___+_---1
/
REF. REFLECTOR: RoMP..,
~R1/
GAIN: 4-'.8 dB CALIBRATION TIMES AMPLITUDE: 5"0 METAL PATH:
.443 INITIAL TIME: 07Sa FINAL TIME: /:1jtJ VERIFICATION TIMES 1)()85'3 2)09(')/
3),y/A 4)#/,.#
1 5),1//..1 6)#/A 7)/Ya 18)#/A' 19)#/...4
- PDI QUALIFIED INSTRUMENT SETTINGS:
VERIFY INSTRUMENT SETTINGS AND CALIBRATION SEQUENCE ARE IN ACCORDANCE WITH TABLE 2 OF THE APPLICABLE PDI QUALIFICATION IMPLEMENTATION PROCEDURE!
LINEARITY CHECK VERTICAL SIGNAL 1 100 90 80 I 70 60 50 40 I 30 20 SIGNAL 2 50 45" 40 l"j~
30
~5" 2f.7 I/~
/0 GAIN I SET
-6 dB
-12dB SET
+12 SET
+6 SIF-D193-03
/
EXAMINER:~se!-/k/~Jo {ltd V L LVL.: :iT
~AN.;;;...;..;;;;.II:~~~
...........----+-
EXAMINER:~~:'!fc.~ ~~-:;17--
I--D_AT_ E_:---=-~-'-(--Lr1----:.I<~/~~?__
REVIEWER: ~.,...().
Sb-LM~.\\-
LVL_~ DATE: l..4 e,.Lk-oq PAGE Z
OF 6
ACCESS. FORMS DATABASE 07-25-07
TENNESSEE VALLEY AUTHORITY DIGITAL ULTRASONIC CALIBRATION DATA SHEET REPORT NUMBER
,Z* f>Qsc8 PROJECT WBN UNIT/CYCLE 2/00 CALIBRATION DATE: OJ, -~-~9 CALIBRATION BLOCK NO. wB83 TEMP: '77./ of PROCEDURE: N-UT-6-1 REV: II TC: IVa SIMULATOR BLOCK: !?"MP4S TRANSDUCER
~-'-=-!.!'¥-==------
MANUFAC
!rBA MODEL:
ComP' G THERMOMETERSIN:f"19oS-DUEDATE:D8-1-l'09 o
I
~
COUPLANT: U/ff...,~/ '$
BATCH:
D&;J.;J. S" r
- ELEMENTS:
I SHAPE:
n 0";
ANGLE VERIFICAnON.~~~~::::~
SIN OiL v4c:
SIZE:
.~)O FREQ:,;].).1' MH2 BLOCK TYPE ROMeltJ SIN:
93 -57,;.4-CONTOUR:
/V/A FOCUS' #/,4 NOMINAL ANGLE: '0 ACTUAL ANGLE 70 0
INSTRUMENT ------.....
CABLE TYPE K6=-/74 LENGTH' 7<<.0
- CNT:~ MANUFACTURER:kr4"fA't'W~;f DUE DATE: 08-/8-09 MODE:.18 SHEAR 0 LONG 0 RL MODEL NO.:
USN '0 SIN: 376S8 20 1--+---+---+-+--+--+--+-+---+----1 80 1--+---+---+-+--+-~--+-+---+----1 60 1--+---+---+-+--+--+--+-+---+----1 100 1--+---+---+-+--,,0"'1'CJol 5'-~""'L...!!!f".L7.!o<.4l C'~---j-----l DAC REFLECTOR REFERENCE MEMORY SCAN DIRECT.
NTC SDH SENSITIVITY NUMBER A
AXIAL
~
0 5'.~ dB 7o~ l,n -ss M
CIRe.
D 0
u[ A: dB Jo-1-A PRANGE:
...1.4()0 inches *FREQ:
- l.~:r MHz L
PROBE DELA 5.f'aS-msec *RECTIFY: full w!i/l't.-
I VELOCITY,//73 msec DUAL D ON
~ OFF T
DISP DELAY: O.DDO
- REJECT:~
U
"-ENERGY:
H*', It
- DISP. START: ZF' D
- DAMPING: lie ohms E
- PRRlPRF: A",w #.'41.
DET: D Peak
~ Flank o
ANGLE' 70
..r deg TCG:
D ON
~ OFF DISPLAY WIDTH
~.4()O inches ZERO: tV44 msec
- PULSER:
S'~4/e.
40 I--+---+---:t~,----'"
j/+i7';J--t-+--+--+---j-----l REF. REFLECTOR: RoM,P~u SJ'h' GAIN: So.7 dB CALIBRATION TIMES AMPLITUDE: SO METAL PATH: 0.9'/
INITIAL TIME:
0'74$-
FINALTIME:/~~8 VERIFICATION TIMES 1)0844 2)DfjD4 3)At/A 4)#/A 1 5)AlhI 6)#d 7)4//..1 18)#/..4 19)#/4
- PDI QUALIFIED INSTRUMENT SETTINGS:
VERIFY INSTRUMENT SETTINGS AND CALIBRATION SEQUENCE ARE IN ACCORDANCE WITH TABLE 2 OF THE APPLICABLE PDI QUALIFICATION IMPLEMENTATION PROCEDURE!
LINEARITY CHECK VERTICAL SIGNAL 1 100 1 90 80 1 70 60 50 40 I 30 20 SIGNAL 2 50 14-5" 4-0 135" 3t>
~;
- lO I/~
I~
GAIN SET
-6 dB
-12dB SET
+12 SET
+6 ATTENUATOR AMP 80%
32 TO 48 l~T~ 24 20%
6~~O 96 -l...:.J68~096 1 ~N---=T=S4-~O-=-=--+-=-=--I=--=-r=--=--- 1,;
J '& *1twE~XAMlNED SIF-D193-03
/\\
/
EXAMINER:~(iU/~J,.o itu( k-lvLVL.: 2-EXAMINER: c~c-- Rt"-e-/~ '-fJ~1 REVIEWER:b 0.1
~"()d2..f.A.
LVL.:..l<.L.-
DATE:lA~'o9 ANII:
DATE:
PAGE :3 OF b
ACCESS: FORMS DATABASE 07-25-07
\\j
TENNESSEE VALLEY MANUAL ULTRASONIC REPORT NUMBER AUTHORITY PIPING EXAMINATION K-eGso8 DATA SHEET ROJECT:
WBN UNIT/CYCLE 2/00 EXAMINATION DATE t::J~ - 2 2. 0 Cf SYSTEM: SIS START TIME:
tJ~1-7 END TIME:
08.57 WELD I.D.: SIF-D193-03 EXAM SURFACE OlD
~OD CONFIG.:
VAL TO P
OCSCL OCCSS MATERIAL TYPE: OCS
~SS FLOW SURFACE TEMP.:
77,'1 PYRONO.
£~C(v<H PROCEDURE:N-UT-to 4 REV:
1/
TC: /11M EXAMINATION ANGLE 45" DEG.
70 DEG.
Wo
REFERENCE:
~Q.{'tveIJ AXIAL SCAN SENSITIVITY
- 39. (,
dB 6';.;<
dB Lo
REFERENCE:
,bc CIRC. SCAN SENSITIVITY 40.8 dB MIA-dB INO L(in) FROM REF.
AT MAX AMP MAX EXAM NOM.
INDICATION INFORMATION:
AMP NO.
NRI NO.
L1 LMax L2 WMAX MPMAX DMAX
%DAC 3-14 ANG.
TYPE, DAMPING, ETC.
4 45" 00 5
4so rn t:.
4~o
~
4 70()
~
0 0
REMARKSILIMITATIONS
/Yo
'Y/1ffllr1trf-/on
<I'c<;z
.-=?
du<. rn t/t::tlve CdO>>1IZ!",u
~Y/.1H1(/JahOY1 LU./'" 1'-
e.d
- (///A-h:tln /HC, 5- ~oCJ/o :rLJ rotI.
See( n""ec/ cIn
/A}~/,.I J
/)
EXAMINER: ~5P I%,;~h(JL /J/~ LEVEL: E ANII:
GJ
~
/
~
1'/~ / dJq
'XAMINER:~~~.a L:~
DATE:
REVIEWEDBY:~"".O" ~.~rA LEVEL::1!I::: DATE:lea<t.-?f PAGE 4-OF b
( \\
ACCESS, FORMS DATABASE 10/18/01
TV
.WAll THICKNESS REPORT NO:
PROFilE SHEET 1<- \\'::>0508 PROJECT: leQ~5 ~ Ow l.¢"y WELD NO:
5.I £- - 'D \\93 - 03 UNIT:
2-SYSTEM: ;s:r;:s Record Thickness Measurementlll Ae Weld
(:, Weld lEdge Indicated, Including Weld Width, Cent.rllnG Edge*To-Edge At O*
f3 2.5" t>~
2.5"
- >1 m rh Posilion 0"
90*
180" 270*
[J]
rn rs1
.~
\\ I) f OJ
.vIc.
-/
~Slde rn
,ld1l
- I u.ak.t'slde "I rn 5'10
/A I
C!l
,4-[;
/
[!)
1,lJ.4'5V Flow CROWN HEIGHT:
ElL! <,,,
DIAMETER:
.30
.EJ4."
fl'{2-II CRQWN WIDTH:
WELD lENGTH:
VA-I ve.
t=~Q 1/2 PI (J-e t/ ~
t.L.
EXAM'NERtfk'\\CL1C.l'p 4
~u',*a...'h REVIEWED 8~9.
9~ep~
ANll: f;J' dT
¥Pe!¢C; LEVEL:
"'!'7!O <7 LEVEL:
l1t:
DAT£' c.. HY -I?fl DAU" DATE:
PAGE
!:)
OF b
I 1VA 19668 (NP-S.89) 1-IOI,~99,44
TVA PROJECT:
WEN SYSTEM:
S.::r.s REPORT Office of Nuclear Power VALVE UNIT:
!="t:. 0 \\IV WELD NO:
S:rF- ]),93- 03 R - Po508
?/?E BY: :J;~ Alea,Jro LEVEL:
dL DATE: "6 it-CJ9' PAGE 6
OF 6
TVA Procedure N-GP-31 Item 1 Item 2 Required examination Volume in sq. in.
(width x height)
Number of scan directions Item 3 Total Scan volume in sq. in.
Item 4 Total length of weld Total required exam volume in cubic Item 5 inches Exam volume achieved (sq. in.) in Item 6 direction 1 X length of weld achieved Exam volume achieved (sq. in.) in Item 7 direction 2 X length of weld achieved Item 8 Item 9 Item 10 Exam volume achieved (sq. in.) in direction 3 X length of weld achieved Exam volume achieved (sq. in.) in direction 4 X length of weld achieved Determined the achivied exam volume add 6,7,8 & 9 Item 11 Exam volume percentage item 10litem 5 x 100 11111:'hel au 51M ¥~
dUe Iv yale/£:-
INFORI~iAlIUI' u~~L\\Y