ML102930358

From kanterella
Jump to navigation Jump to search
NDE Report R-P0405
ML102930358
Person / Time
Site: Watts Bar Tennessee Valley Authority icon.png
Issue date: 10/11/2010
From:
Tennessee Valley Authority
To:
Office of Nuclear Reactor Regulation
References
R-P0405
Download: ML102930358 (7)


Text

TENNESSEE VALLEY AUTHORITY EXAMINATION

SUMMARY

AND RESOLUTION SHEET REPORT NUMBER:

~.P04oS" PROJECT: WBN UNIT:

2 CYCLE 00 COMPONENT In: SIF-D199-07 EXAMINATION METHOD SYSTEM: SIS lSI DWG NO: ISI-2063-W-08

. 0 MT D

PT D

UT

~

VT D

CONFIGURATION:

CATEGOR_

PROCEDURE:N-UT-64 REV

/1 TC: IV ~

VLV TO EL B-J EXAMINER:

EXAMINER:

EXAMINER:

EXAMINER:

ry;xA0irtk 0 LEVEL:

~

Total coverage calculated to be approximately

'1o,,3S" %

1;e1z:a¥b~~2!t;5 51c~lrL{/e~;a'f:/fj:JL~:~4 o~s Jl~ U-th'llltahdl1 St!et/'l,3 fl-r:l::h-tItLd dfL..e.. 10 valvc..

gedtrl 1-1!

ACCESS: FORMS DATABASE R-10/04/01 LEVEl:;: L DATE: ~

~ - 0 ANII:

Page:

L-OF~

TENNESSEE VALLEY AUTHORITY DIGITAL ULTRASONIC CALIBRATION DATA SHEET REPORT NUMBER S?-.,? 0 Llo5 PROJECT WBN UNIT/CYCLE 2/00 CALIBRATION DATE: (J'-O/-09 CALIBRATION BLOCK NO.w883 TEMP: 71. '7 OF PROCEDURE: N-UT-64 REV: II TC: K/tL SIMULATOR BLOCK: 8.MP4S TRANSDUCER

~"--'OLl!~.'---'-""'--

MANUFAC KBI'I MODEL:

CO~-(;

THERMOMETER SIN: S,~ 7'JJ DUE DATE:bf,-A"*""

COUPLANT:t(/p4\\..1...../;p:.

BATCH:

"'~fAS"f

  1. ELEMENTS:

I SHAPE: 904"'/

ANGLE VERIFICATION ~~~:::::::~

SIN OlrllfJ-r SIZE:

.37,-

FREQ: /.r M

BLOCKTYPEtf~... )

SIN:

o3I:fo CONTOUR:

/V/A FOCUS' #/A NOMINAL ANGLE: 45'""

ACTUAL ANGLE 4-S'" 0 INSTRUMENT ------.......

CABLETYPER6l/74 LENGTH:

7~." #CNT:~ MANUFACTURER:IV~,nt~....... DUEDATE:b,.;lJ~'

MODE:

~ SHEAR 0 LONG 0 RL MODEL NO.:

USN,~

SIN: t:3'St>!-

CIRe.

0 A

M P

L I

T U

D E

DAC REFLECTOR REFERENCE MEMORY SCAN DIRECT.

SDH SENSITIVITY NUMBER AXIAL 0

SIGNAL 1 SIGNAL 2 GAIN SET 20 t---+--+---+-t--+--+--+-t--+----I 40 t---+-~'H'I=----t--+--+--+-t--+----I 60 t---+--+---+-t--+--+--+-t--+----I 80 1---+--+--+-+---+--'+---+-+---+--1 100 t---+--+---+-t----tn""""f-;~'I.4-'l"""--+----I VERTICAL LVL.:tC DATE: Cc'c?;:lo ANII:

DATE:

PAGE d.-

OF Co

TENNESSEE VALLEY AUTHORITY DIGITAL ULTRASONIC CALIBRATION DATA SHEET REPORT NUMBER

~. ?()LlDS PROJECT WBN UNIT/CYCLE 2/ 00 CALIBRATION DATE:

tM,* t) I ~ 0 PROCEDURE: N-UT-64 REV:

II TC: N/A CALIBRATION BLOCK NO. 11113 8'3 TEMP: 7/. 7 OF 1-':~=':':':::';:::TiW~

SIMULATOR BLOCK:

RompttJ BLOC!c

~

TRANSDUCER i

MANUFAC 1<<1)

MODEL:

{teL* 2 THERMOMETER SIN:S"..?773 DUE DATE: (J1:r-;({}'O~

  1. ELEMENTS:;J, SHAPE: 1?ec!tJI1]/-e.

COUPLANT: tt'~~Li:~RiiI<~~~I~:: Ok ~:2S'P SIN

~5-~3q SIZE:;J. (8KI1)FREQ:;l.6 MH BLOCKTYPE 120fJ1j?a~

SIN:

7/i0390 CONTOUR' N ~

FOCUS' tV'l1-NOMINAL ANGLE: ?ORt.-

ACTUAL ANGLE 7tJRt.

II

/ I

  • ~ST~UMENT CABLE TYPE Rtr /74 LENGTH: 'l2t2
  1. CNT:~ MANUFACTURER:;rral1f-(rel!J1e~DUE DATE: 6,,-;3-09 MODE:

D SHEAR D LONG

~ RL MODEL NO.:

tts~()

VERIFICATION TIMES AMPLITUDE: 50 %

20 t---r--+---+-t---r--+--+-t----r---l SIGNAL 2 SIGNAL 1 GAIN SET S

40 t----t-=~CL...f-t---r--+--+-t---+---l 60 t---r--+---+-t----r--+--+-t----r---l VERTICAL DAC REFLECTOR REFERENCE MEMORY t--:::-;::::::;;:::::;::::::::::::~=::;:::::;::::::::::::;;::::::---"VS;CCiiANS-DDiI[RREE4C:lT:::-.

rNTCT"5siiiD*Hl1 SENSITIVITY NUMBER 100 t---r--+---+-t---7--17'r-lt7~~t----r---l D

A AXIAL 80 t---r--+---+-t---<<_-+--+-t----r---l M

CIRC.

D P

L I

T U

D E

SIF-Dl99-07 ACCESS: FORMS DATABASE 07*25-07 LVe:: ( (

DATE:~~

ANII:

DATE:

PAGE OF CR

TENNESSEE VALLEY MANUAL ULTRASONIC REPORT NUMBER AUTHORITY PIPING EXAMINATION

~,'?ol\\.oS DATA SHEET ROJECT:

WBN UNIT/CYCLE 2/00 EXAMINATION DATE t')~ 09 SYSTEM: SIS START TIME:

/014-END TIME:

/O,:({

WELD I.D.: SIF-DJ99-07 EXAM SURFACE DID

~OD CONFIG.:

VLV TO EL>

MATERIAL TYPE: DCS l&JSS DCSCL DCCSS FLOW SURFACE TEMP.:

84,(p PYRO NO. 5~~ 773 PROCEDURE:N-UT-64 REV:

/I TC:

/VA EXAMINATION ANGLE 45' DEG.

70RL DEG.

Wo

REFERENCE:

~.".fNeJd AXIAL SCAN SENSITIVITY 3:<.3 dB 74.5" dB Lo

REFERENCE:

--r/)c.

CIRC. SCAN SENSITIVITY 4tJ.6 dB

/Vld dB INO L (in) FROM REF.

AT MAX AMP MAX EXAM NOM.

INDICATION INFORMATION:

AMP NO.

NRI NO.

L1 LMax L2 WMAX MPMAX DMAX

%DAC 3-14 ANG.

TYPE, DAMPING, ETC.

4 4S()

~

5 45'(1 00 tP 4$0

[Zl 4

0

~

7CJRL D

D REMARKSILIMITATIONS AI",

~ X"a I11trlar/C:;rt

-:;ea '1 3

da-L 0 Va /l/~

4 eo,j! -f-",u.

?Vd U1/ 'v1r;.ft'b rt IJ-e r.f'c.;r#1J UA/Ltn In hl"nc, 5-';U) '10

z:LJ roll,

~ea../1n <:"d t<J PI uiP {A J

/'

EXAMINER:~ill,.

~o {/J ~/..h LEVEL: ::7L ANII:

(jj)

'XAMINER:~"-~x!:di::- '.L2A VEL: -:#C DATE:

CtJ. (l~ (d>'i REVIEWEDBY'~

nlJ~...(1MA LEVEL: Il,.....

DATE: (e,.q.<8 PAGE tt.

OF

~

(J ACCESS: FORMS DATABASE 10/18/01

PROJECT:..w.f~ 8#d' /V"'*;f/(

UNIT:

c2.

WELD NO: --:S:,.:r.::.Lf_"'.t:;.f)..!-/t-J'f'f!--.::"-1 SYSTEM:_..:5~Z.:=:S~

TVA

.WALL THICKNESS PROFILE SHEET REPORT NO:

Record Thickness Measurements As Indlc.ted, Including Weld Width, Edge*To-Edge At O*

Position O*

90*

180*

270*

CROWN HEIGHT:

_-.:..:::...;;:~:.....-

CRQWN WIDTH:_-..:..:.=:.=...


1~---2.5"----.~

II DIAMETER: __

,~.()!l::.......

WELD LENGTH:_..J....I:,,;*Vw():.....-

ANII:

EXAMINER:__!..,I&t.~~~~:::..:....--

LEVEL:

,.;,;..::~

DATE:

'IVA 19668 (NM.S9)

REVIEWED 8Y~(~' Of*

I

~.-...o I ID~A~TE:.::*=:;;::::~=::::;.:~===__1 LEVEL:

I DATE: Cd ~...~ t-o PAGE HOI**....

PROJECT: W.I'm'ffAr#ltct.&'l/£ SYSTEM:

5:1S

-~=------

TVA Office of Nuclear Power VAL. !/E UNIT:

~

WELD NO:

S ~r:J)1'9 - 07 Bow REPORT Nu.:

~'?04()~-

£2.Bow oc>

0/1 G s,Wt:)

C~4n,"'" "-~J;,.,,

PL-t... h J;..1'Wl'/ or V,,/pG.

BY: ~ /IItII-J-v

~

LEVEL:

IT DATE:

O~~-). 7-d'7 PAGE

<0 OF

~

TVA Procedure N-GP-31 Item 1 Required examination Volume in sq. in.

(width x height)

Item 2 Number of scan directions Exam volume achieved (sq. in.) in direction 3 X length of weld achieved Item 8 Item 3 Total Scan volume in sq. in.

Item 4 Total length of weld Total required exam volume in cubic Item 5 inches Exam volume achieved (sq. in.) in Item 6 direction 1 X length of weld achieved Exam volume achieved (sq. in.) in Item 7 direction 2 X length of weld achieved Item 9 Exam volume achieved (sq. in.) in direction 4 X length of weld achieved Item 10 Determined the achivied exam volume add 6,7,8 & 9 Item 11 Exam volume percentage item 10/item 5 x 100