ML102930340
| ML102930340 | |
| Person / Time | |
|---|---|
| Site: | Watts Bar |
| Issue date: | 10/11/2010 |
| From: | Tennessee Valley Authority |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| R-P0305 | |
| Download: ML102930340 (7) | |
Text
{{#Wiki_filter:* TENNESSEE VALLEY AUTHORITY EXAMINATION
SUMMARY
AND RESOLUTION SHEET REPORT NUMBER: ~.? 05b'$" PROJECT: WBN UNIT: 2 CYCLE 00 COMPONENT ID: SIF-D197-09 t-..........~=-T"E_X...A...M_I_N....A....T"TIO_N_M_E_T_H__O;...D-r-__-=-1I-SY_ST_E_M_:S_I.... S~.l..I...S....I D~W-:-::G....N:-:O__:_IS_'I-..,2_06_3_-W_-_0_6---i v. 0 MT D PT D UT ~ VT D CONFIGURATION: CATEGOR PROCEDURE:N-UT-64 REV 11/ TC: N ~ VLV TO EL B-J EXAMINER: EXAMINER: EXAMINER: EXAMINER: ':];$e.Azy tJ:l.f-.C2 LEVEL:
- .:rr:-
Total coverage calculated to be approximately
- 74. =2 t. %
RESOLUTION BY: ~ LEVEL dJ-DATE: 04 *).q-o~ ACCESS: FORMS DATABASE R-10/04/01 ~EWE.DB~ . ~'--6~ e.P ~ LEVEC=t1/- DATE: C;- Lt-ANII: DAT-i:--5713-*7~?- Page: --L-OF~
TENNESSEE VALLEY AUTHORITY DIGITAL ULTRASONIC CALIBRATION DATA SHEET REPORT NUMBER ~<l>o3oS-MANUFAC MODE: ~ SHEAR PROJECT WBN UNIT/CYCLE 2/00 CALIBRATION DATE: 0
- ~9*o9 CALIBRATION BLOCK NO. wB sa TEMP: 7,t},j of PROCEDURE: N*UT*64 REV:
Ii TC: N1A TRANSDUCER SIMULATOR BLOCK,,-:.L&.v.tl~W'/~r::....:.""'~;; kBA MODEL: COMr-c; THERMOMETER SIN: 55'8.1.71 DUE DATE:b.-.;/4*o'! COUPLANT: klk49~1 1l BATCH: ()'A~:f' r
- ELEMENTS:
I SHAPE: {f"til1P! ANGLE VERIFICATION.~~~~:::~ SIN Oh~H<f'1j SIZE: .$7r FREQ: I,~ MH BLOCKTYPE.,f':Mllt't!!J SIN:_7<.-tj"'-C-o"-'J""-L-'to"'---- CONTOUR: /11/4 FOCUS' AI/A NOMINAL ANGLE: If'([ AC.:.TU:A:L:.A::N~G:L:E~+~5~°:.1 ~ - INSTRUMENT CABLE TYPE 86--/7+ LENGTH: 7~. () # CNT:~ MANUFACTURER:kr4",~m.::.-A DUE DATE:o,..7,J-Pq DLONG DRL MODEL NO.: t15d/ ~o SIN: t:3630./t MEMORY NUMBER 30.4 dB ANII: PAGE ~ OF (P DATE: SIGNAL 2 SIGNAL 1 GAIN SET 5 ~~'LLIl:i...Jl~~~4{-,~~!:]) LVL.: ;jf ~~~~~~~~~/:..-"LVL.~ LVL.~ DATE:"\\ "'ll 40 60 1----+-'--+-----+-+__-1--+---+-+-0---1---1 20 1----+-'--+-----+-+__-1--+---+-+--1---1 VERTICAL REVIEWER: ~-.>c_ DISPLAY WIDTH '3, gOt:! inches REF. REFLECTOR: (fDnt;;"'f ~,t1If GAIN: 35,3 dB AMPLITUDE: 50 METAL PATH:
- if 1f.J VERIFICAnON TIMES t~=-;::=;::::;=;=:;:D=A;::C:;::::;:=:=::=::-"""''''SGoomRuE:cFT.L1ECrT~0r<R:rsrrH1REFERENCE SCAN DIRECT.
SDH SENSlTMTY 100 1----+-'--+-----+-+__---t.4~__/,I4~<j-(.ooJ'H----I D A AXIAL 80 I----+-'--+-----+~+__-+-i~'_____+-+--I---I M CIRC. D P L I T U D E
TENNESSEE VALLEY AUTHORITY DIGITAL ULTRASONIC REPORT NUMBER CALIBRATION DATA SHEET ~" \\:=>03DS PROJECT WBN UNIT/CYCLE 21 00 CALIBRATION DATE: 04 *,;19-1:1 CALIBRATION BLOCK NO. we 8J TEMP: '74:3 OF PROCEDURE: N-UT-64 REV: /I TC: /t/~ SIMULATOR BLOCK: BO/~e4J TRANSDUCER ~~~i=~----- MANUFAC 8TO MODEL: TIU-~ THERMOMETER SIN: 5"58a7/ DUEDATE:o,-.,14-of 17 L COUPLANT: Ulr/6gel 7k BATCH.: O';2il5' r
- ELEMENTS:
~ SHAPE: [lec.rM~/e.- ANGLE VERIFICATION ~~~~::::..I SIN 85""'3,7 SIZE: ~(8J(/"') FREQ: ~.o MH BLOCK TYPE 80M,R41 SIN: '790J'1(> CONTOUR: #/A FOCUS* A//A NOMINAL ANGLE: 701ft. ACTUAL ANGLE70""'° INSTRUMENT --------1 CABLE TYPE,fc;.174 LENGTH: 7~.t>
- CNT:d-MANUFACTURER:A!ar.4/&-~£';(
MODE: D SHEAR D LONG 1&1 RL MODEL NO.:. USA! '0 MEMORY NUMBER A//A 4/. '4-dB SIGNAL 2 SIGNAL 1 GAIN SET 20 I--+--+--If--+--+--+-+--I--+---l 40 1-~rf-*f'1-1'----+--+--+-+--I--+---l 60 I--+--+--I-+--+--+-+--I--+---l VERTICAL DISPLAY WIDTH '.5'1>0 inches REF. REFLECTOR: 8oMfl\\f SP# GAIN: '.1> AMPLITUDE: 5"0 METAL PATH: VERIFICATION TIMES DAC REFLECTOR REFERENCE t--:::-;=:;::::::;:::;=~:e:::;:::::;=:;:::;;:::;,---fscSC:::;AN~D;UlREW:ciT.Tl~CTss:UD;EHl1 SENSITIVITY 100 1--+--+--I-+--+-h-1O;:::---;.I'V(~~L-.I D A AXIAL 80 I--+--+--I-+--+---..fe..::....-+--I--+---l M CIRe. D P L I T U D E EXAMINER: ---"~:":'+~LIlC..:~~ LVL.: \\ u.::- DATE: <;~ ANII: DATE: PAGE :3 OF
TENNESSEE VALLEY AUTHORITY MANUAL ULTRASONIC REPORT NUMBER PIPING EXAMINATION ~.Po30S" DATA SHEET ROJECT: WEN UNIT/CYCLE 2 / 00 EXAMINATION DATE IJ4. ~ 9-O'j SYSTEM:S-L--S~-- START TIME: -/-{BG-END TIME: ~ 00 WELD I D 9 0 J'Jt "tlfU-9"'1 71'/- u'l-l'-tif' ..: SIF-DI 7-9 EXAM SURFACE DID ~ OD CONFIG.: VLV TO EL >I MATERIAL TYPE: DCS C8!SS DCSCL DCCSS FLOW SURFACE TEMP.: 77,9 PYRONO. 55"8:271 PROCEDURE:N-UT-64 REV: -i.L. TC: )/It! EXAMINATION ANGLE 4-5 DEG. 70 RL. DEG. Wo
REFERENCE:
__?i;;;;;......;();;..;./~W_le_/~~d_____ AXIAL SCAN SENSITIVITY 41, :2 dB (p 4.~ dB Lo
REFERENCE:
,bc.. CIRC. SCAN SENSITIVITY 44./, dB ~ ~ ~ dB IND L (in) FROM REF. AT MAX AMP MAX EXAM NOM. NO AMP NO. ANG L1. L Max L2 WMAX MP MAX D MAX % DAC 3-14 NRI INDICATION INFORMATION: TYPE, DAMPING, ETC. 5 45() lKJ D D REMAip(SILIMITATIONS ;flo eK(/#1 J~ f..i<J n Sl'A-/f/6 :5-frt911t Vtuve.sid-e E"KtrH!tna-!to;? lJel'./::;r #t~/I JHAil4 f~iu //10, 5'"- 2~ r/4 r /.) I"tlif. >>aVI /'1ec/ t9/f aJ e rei. J /1 EXAMINER..<t:: Aft. L (jfll/u. L LEVEL: :If' XAMINER:£~~#'r.-/~OAVEL:L.. REVIEWED BY~ rJ ~(I'J" LEVEL: Lu: DATE:c;-U'd'( o ACCESS. FORMS DATABASE 10/18/01 ANII: Q DATE: S-//3 (r69 PAGE i.{ OF ~
TVA PROJECT:J#A TIS N/(/YutiC:AR SYSTEM:_.....::::S-=--'.]:~S Office of Nuclear Power 'UNIT: ~ WELD NO: SZr-j?/r7-o9 REPORT NO.: ~.P03D5 VAL-V£ ~o/.(/ I:lBow Or;) BY: LEVEL: JI DATE: &4--;'["-0; PAGE 5 OF r.a
PROJECT:.WdZlf.9#£ tVttet.tTAR UNIT: ~ TVA .WALL THICKNESS PROFILE SHEET WELD NO: 51(-$17 -09 SYSTEM: SIS REPORT NO:
- Weld Edge DIAMETER: _...;/:.,.0;.......;.cJ;.......;
WELD L!NGTH:.....,..;3;;...;;..5:.=...,7:...~=---O Weld Centtrllne 11"'III..1----2.5"---... ~1......---2.5..----+~1 Cil flow. CROWN HEIGHT: __~..;;;.:.:~ CRQWN WIDTH:__...;:...~ Posilion O* 90" 180* 270* Record Thlckn... M...ur.ment. As Indlc.ted. Including Weld Width, Edge*To-Edge At O* VALVe-eL.Bow O~ EXAMINER:_--:..,-q;~~~Lh..:...- LEVEL: --...~~.-."..---- DATE: ~ ~ W O ANIl: REVIEW~ 8Y:~Q<'_Q~ ---.;~........._I_.~~-- ~- U di3(<P9 LEVEL: W+- DATE:S-H'D7 J.,:D:.::A~TE:'::;:;::=~=*=======--1 PAGE TVA 19668 (NP.S-89)
TVA Procedure N-GP-31 Item 1 Item 2 Required examination Volume in sq. in. (width x height) Number of scan directions Item 8 Item 9 Item 10 Exam volume achieved (sq. in.) in direction 3 X length of weld achieved Exam volume achieved (sq. in.) in direction 4 X length of weld achieved Determined the achivied exam volume add 6,7,8 & 9 Item 11 Exam volume percentage item 10/item 5 x 100}}