ML102460429
| ML102460429 | |
| Person / Time | |
|---|---|
| Site: | Davis Besse (NPF-003) |
| Issue date: | 08/27/2010 |
| From: | Allen B FirstEnergy Nuclear Operating Co |
| To: | Office of Nuclear Reactor Regulation, Document Control Desk |
| References | |
| L-10-253 | |
| Download: ML102460429 (8) | |
Text
FENOC 0 %
5501 North State Route 2 FirstEnergy Nuclear Operating Company Oak Harbor, Ohio 43449 Barry S. Allen 419-321-7676 Vice President - Nuclear Fax: 419-321-7582 August 27, 2010 L-10-253 10 CFR 54 ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
Davis-Besse Nuclear Power Station, Unit No.1 Docket No. 50-346, License Number NPF-3 License Renewal Application Boundary Drawings By the referenced letter, FirstEnergy Nuclear Operating Company (FENOC) submitted the License Renewal Application (LRA) for Davis-Besse Nuclear Power Station, Unit No. 1. The LRA references license renewal boundary drawings used in support of the scoping phase of the license renewal project. Enclosed is a copy of the license renewal boundary drawing index and the boundary drawings, which are provided to aid the Nuclear Regulatory Commission staff in the review of the License Renewal Application.
No new regulatory commitments are contained in this submittal. If there are questions or if additional information is required, please contact Mr. Clifford Custer, Fleet License Renewal Project Manager, at 724-682-7139 or Mr. Gregory H. Halnon, Fleet Director, Regulatory Affairs, at 330-384-5638.
Sincerely, Barry S. Allen
Reference:
FENOC Letter L-10-221, "License Renewal Application," August 27, 2010.
Davis-Besse Nuclear Power Station, Unit No. 1 L-1 0-253 Page 2
Enclosures:
A License Renewal Application Boundary Drawing Index B
License Renewal Application Boundary Drawings cc:
B. K. Harris, NRC DLR Project Manager P. E. Cooper, NRC DLR Project Manager M. A. Satorius, NRC Regional Administrator, Region III NRC Resident Inspector cc:
w/o Enclosures NRC DLR Director NRR Project Manager Utility Radiological Safety Board
Enclosure A Davis-Besse Nuclear Power Station, Unit 1 Letter L-1 0-253 License Renewal Application Boundary Drawing Index (3 pages)
Davis-Besse License Renewal Application License Renewal Boundary Drawing Index No Drawing Description 1
LR-M001-00 Piping Symbols & Diagrams Index 2
LR-MO01-01 Piping Symbols & Diagrams Index - General License Renewal Notes 3
LR-M002 Instrumentation Symbols 4
LR-MO03A Main Steam and Reheat System - Sheet 1 5
LR-MO03B Main Steam and Reheat System - Sheet 2 6
LR-MO03C Main Steam and Reheat System - Sheet 3 7
LR-MO06D Auxiliary Feedwater System 8
LR-MO06E Condensate System 9
LR-MO07A Steam Generator Secondary System 10 LR-MO07B Steam Generator Secondary System 11 LR-M009B Cooling Water System 12 LR-MO10C Make-up Water Treatment System 13 LR-M010D Make-up Water Treatment System 14 LR-MO1 1 Domestic Water System 15 LR-MO12E Screen Wash and Cooling Tower Make-up System 16 LR-MO15A Instrument Air System 17 LR-MO15D Station Air System 18 LR-MO16A Station Fire Protection System 19 LR-MO16B Station Fire Protection System 20 LR-MO17A Diesel Generators 21 LR-MO17B Diesel Generators Air Start 22 LR-MO17C Fuel Oil 23 LR-MO17D Station Blackout Diesel Generator 24 LR-M019 Nitrogen Supply System 25 LR-M020A Water Treatment & Intake Structure Auxiliary Steam System 26 LR-M020B Auxiliary Building Auxiliary Steam System 27 LR-M020D Turbine Building Auxiliary Steam System 28 LR-M021 Station Heating System 29 LR-M022A Main Turbine Gland Steam Seal & Drain System 30 LR-M024G No. 1 Main and Auxiliary Turbine Driven Feed Pumps 31 LR-M024H No. 2 Main and Auxiliary Turbine Driven Feed Pumps 32 LR-M026A HV & A/C Air Flow Diagram Turbine Building & Auxiliary Feed Pump Room 33 LR-M026B HV & A/C Air Flow Diagram Water Treatment Building and Miscellaneous Yard Structures 34 LR-M026B01 HV & A/C Air Flow Diagram Water Treatment Building and Miscellaneous Yard Structures 35 LR-M027A HV & A/C Air Flow Diagram Auxiliary Building Non Radioactive Areas and Control Room 36 LR-M027B HV & A/C Air Flow Diagram Auxiliary Building Non Radioactive Areas 37 LR-M028B HV & A/C Air Flow Diagram Aux. Bldg. Radwaste, Fuel Handling and Access Control Areas 38 LR-M028C HV & A/C Air Flow Diagram Auxiliary Building Radwaste Ventilation 39 LR-M028D HV & A/C Air Flow Diagram Fuel Handling Area Ventilation Page 1 of 3
Davis-Besse License Renewal Application License Renewal Boundary Drawing Index No Drawing Description 40 LR-M029B HV & A/C Air Flow Diagram Containment and Penetration Rooms
- Sheet 1 41 LR-M029C HV & A/C Air Flow Diagram Containment and Penetration Rooms
- Sheet 2 42 LR-M029D HV & A/C Air Flow Diagram Containment and Penetration Rooms
- Sheet 3 43 LR-M029E HV & A/C Air Flow Diagram Containment and Penetration Rooms
- Sheet 4 44 LR-M030A Reactor Coolant System 45 LR-M030B Reactor Coolant System Instrumentation 46 LR-M031A Make Up & Purification System 47 LR-M031 B Make Up & Purification System 48 LR-M031C Make Up & Purification System 49 LR-M033A High Pressure Injection 50 LR-M033B Decay Heat Train 1 51 LR-M033C Decay Heat Train 2 52 LR-M034 Emerg. Core Cooling System Ctmt. Spray & Core Flooding Systems 53 LR-M035 Spent Fuel Pool Cooling System 54 LR-M036A Component Cooling Water System 55 LR-M036B Component Cooling Water System 56 LR-M036C Component Cooling Water System 57 LR-M037C Clean Liquid Radioactive Waste System 58 LR-M037D Clean Liquid Radioactive Waste System 59 LR-M037E Clean Liquid Radioactive Waste System 60 LR-M037F Clean Waste Monitor Tanks 61 LR-M037G Boric Acid Evaporator 1-1 62 LR-M037H Boric Acid Evaporator 1-2 63 LR-M038A Gaseous Radwaste Hydrogen and Oxygen Monitoring Systems 64
,LR-M038B Gaseous Radioactive Waste System 65 LR-M038C Gaseous Radioactive Waste System 66 LR-M039A Miscellaneous Liquid Radioactive Waste 67 LR-M039B Miscellaneous Liquid Radioactive Waste 68 LR-M040A Reactor Coolant System Details 69 LR-M040D Reactor Coolant Pump & Motor 70 LR-M041A Service Water Pumps and Secondary Service Water System 71 LR-M041B Primary Service Water System 72 LR-M041C Service Water System for Containment Air Coolers 73 LR-M042B Sampling System Sh. 2 Local Grab Samples 74 LR-M042C Sampling System Sh. 3 75 LR-M043 Auxiliary Building Chilled Water System 76 LR-M045 Chemical Addition Systems 77 LR-M046 Station Drainage Systems 78 LR-M047 Radwaste Drumming Station 79 LR-M090 Station Plumbing and Drains 80 LR-M269P Sprinkler Sys. S.W. Valve Room Intake Structure Elev. 566'-0" 81 LR-M281N13 System Line I.D. for Radwaste Demineralizer Skid Page 2 of 3
Davis-Besse License Renewal Application License Renewal Boundary Drawing Index No Drawing Description.
82 LR-M33301 Fire Protection Piping Sprinkler System Room 303 Auxiliary Building Elev. 585'-0 83 LR-OS002 Makeup and Purification System 84 LR-OS041A1 Emergency Diesel Generator Systems 85 LR-OS041A2 Emergency Diesel Generator Systems Page 3 of 3
Enclosure B Davis-Besse Nuclear Power Station, Unit 1' Letter L-1 0-253 License Renewal Application Boundary Drawings (85 pages)
THE 85 SUBSEQUENTLY LISTED DRAWINGS/FIGURES HAVE BEEN PROSSED INTO ADAMS.
THESE DRAWINGS CAN BE ACCESSED WITHIN THE ADAMS PACKAGE OR BY PERFORMING A SEARCH ON THE DOCUMENT/REPORT NO.