ML102090390
| ML102090390 | |
| Person / Time | |
|---|---|
| Site: | Crystal River |
| Issue date: | 01/12/2010 |
| From: | Mark Franke NRC/RGN-II/DRS/EB3 |
| To: | Cauffmann C NRC/NRR/DIRS/IRIB |
| References | |
| FOIA/PA-2010-0116 | |
| Download: ML102090390 (1) | |
Text
Franke, Mark From:
Franke, Mark Sent:
Tuesday, January 12, 2010 3:58 PM To:
Cauffman, Christopher Cc:
Haskell, Russell
Subject:
RE: Crystal River SIT (Containment)
Hi Chris, We do not have an exit date set.
Two SIT Charter items depend on a licensee root cause analysis and a corrective action.
- 5. Assess the licensee's activities related to the problem investigation (e.g., root cause analysis, extent of condition, etc).
- 6. Assess the licensee's corrective action/"fix" in addressing the containment delamination issue.
The licensee hopes to have a root cause by end of January and hopes to have a repair (corrective action) plan sometime in February.
Based on the current schedule, the SIT public exit would most likely be in March.
From: Cauffman, Christopher 1"'*
Sent: Tuesday, January 12, 2010 3:36 PM To: Franke, Mark Cc: Haskell, Russell
Subject:
Crystal River SIT (Containment)
- Franke, With regards to the Crystal River SIT:
What date did we do the exit meeting or what date do we plan on exiting, if known?