Text
Exek,n.,
PxtIon NuIQIr wwwxeloncorpcom 200 Exelon Way Nuclear
- eiiiett :eUai-e-, PA iCJ4 10 CFR 50.55a July 27, 2010 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353
Subject:
Response to Request for Additional Information
- Submittal of Relief Request l3R-14 Concerning Nozzle-to-Vessel Weld and Inner Radii Examinations
References:
1)
Letter from P. B. Cowan (Exelon Generation Company, LLC) to U.S.
Nuclear Regulatory Commission, Submittal of Relief Request 13R-14 Concerning Nozzle-to-Vessel Weld and Inner Radii Examinations, date February 1,2010 2)
Letter from P. Bamford (U.S. Nuclear Regulatory Commission) to M.
J. Pacilio (Exelon Nuclear), Limerick Generating Station, Units 1 and 2
Request for Additional Information Regarding Relief Request I3R-14, Nozzle-to-Vessel Weld and Inner Radii Examinations (TAC NOS.
ME3306 and ME3307), dated June 25, 2010 In the Reference 1 letter, Exelon Generation Company, LLC (EGC), requested relief from the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code, Section Xl, Rules for lnservice Inspection of Nuclear Power Plant Components. Relief Request 13R-14 proposes an alternative to the requirements contained in Table IWB-2500-1 concerning nozzle-to-vessel weld and nozzle inner radii examination requirements.
In the Reference 2 letter, the U.S. Nuclear Regulatory Commission requested additional information. Attached is our response.
www.exeloncorp.com Exelon Nuclear 10 CFR 50.55a July 27, 2010 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Limerick Generating Station, Units 1 and 2 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353
Subject:
Response to Request for Additional Information - Submittal of Relief Request 13R-14 Concerning Nozzle-to-Vessel Weld and Inner Radii Examinations
References:
1)
Letter from P. B. Cowan (Exelon Generation Company, LLC) to U.S.
Nuclear Regulatory Commission, IISubmittal of Relief Request 13R-14 Concerning Nozzle-to-Vessel Weld and Inner Radii Examinations,lI date February 1, 2010 2)
Letter from P. Bamford (U.S. Nuclear Regulatory Commission) to M.
J. Pacilio (Exelon Nuclear), IlLimerick Generating Station, Units 1 and 2 - Request for Additional Information Regarding Relief Request 13R-14, Nozzle-to-Vessel Weld and Inner Radii Examinations (TAC NOS.
ME3306 and ME3307),1I dated June 25, 2010 In the Reference 1 letter, Exelon Generation Company, LLC (EGC), requested relief from the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code,Section XI, IIRules for Inservice Inspection of Nuclear Power Plant Components. II Relief Request 13R-14 proposes an alternative to the requirements contained in Table IWB-2500-1 concerning nozzle-to-vessel weld and nozzle inner radii examination requirements.
In the Reference 2 letter, the U.S. Nuclear Regulatory Commission requested additional information. Attached is our response.
Response to Request for Additional Information
Submittal of Relief Request I3R-14 Concerning Nozzle-to-Vessel Weld and Inner Radii Examinations July 27, 2010 Page 2 No regulatory commitments are contained in this letter.
Should you have any questions concerning this letter, please contact Tom Loomis at (610) 765-5510.
Sincerely, 49%7 David P. Helker Manager Licensing & Regulatory Affairs Exelon Generation Company, LLC
Attachment:
Response to Request for Additional Information
- Relief Request l3R-14 cc:
USNRC Region I, Regional Administrator USNRC Senior Resident Inspector, LGS USNRC Project Manager, LGS R. R. Janati, PA Bureau of Radiation Protection Response to Request for Additional Information -
Submittal of Relief Request 13R-14 Concerning Nozzle-to-Vessel Weld and Inner Radii Examinations July 27,2010 Page 2 No regulatory commitments are contained in this letter.
Should you have any questions concerning this letter, please contact Tom Loomis at (610) 765-5510.
Sincerely, David P. Helker Manager - Licensing &Regulatory Affairs Exelon Generation Company, LLC
Attachment:
Response to Request for Additional Information - Relief Request 13R-14 cc:
USNRC Region I, Regional Administrator USNRC Senior Resident Inspector, LGS USNRC Project Manager, LGS R. R. Janati, PA Bureau of Radiation Protection
Attachment Response to Request for Additional Information Relief Request 13R-14 Attachment Response to Request for Additional Information Relief Request 13R-14
Response to Request for Additional Information Attachment Relief Request l3R-14 Page 1 Request:
1.
Please expand the synopsis of what inspections have already been performed on the components for which this alternative is requested to include all indications that were found and how these indications were dispositioned.
If no indications were found during any inspections, please state so.
Rewonse:
The following tables identify the Recordable Indications (RI) and Non-Recordable Indications (NRI) identified during the inspections. All the indications were evaluated as acceptable per ASME Section Xl.
Table 1
- Unit 1 Nozzle-to-Vessel and Nozzle Inner Radius Inspection Results Unit J Component }
Outage [Interval I Period Results Misc.
1 N17A 1R04 1
2 NRI 1
N17A 1R07 2
1 NRI 1
N17A-IR 1R04 1
2 NRI 1
N17A-lR 1R07 2
1 NRI 1
N17B 1R04 1
2 RI Recordable indications identified-acceptable per ASME Section XI 1
N17B 1R07 2
1 NRI 1
N17B 1R12 3
1 NRI 1
N17B-lR 1R04 1
2 NRI 1
N17B-IR 1R07 2
1 NRI 1
N17B-IR 1R12 3
1 NRI 1
N17C 1R04 1
2 RI Recordable indications identified-acceptable per ASME Section Xl 1
N17C 1R11 2
3 NRI 1
N17C-IR 1R04 1
2 NRI 1
N17C-lR 1R11 2
3 NRI 1
N17D 1R04 1
2 RI Recordable indications identified-acceptable per ASME Section Xl 1
N17D 1R07 2
1 NRI 1
N17D-lR 1R04 1
2 NRI 1
N17D-lR 1R07 2
1 NRI 1
N2A 1R02 1
1 NRI 1
N2A 1R07 2
1 NRI 1
N2A 1R12 3
1 NRI 1
N2A-IR 1R02 1
1 NRI 1
N2A-lR 1R07 2
1 NRI 1
N2A-lR 1R12 3
1 NRI 1
N2B 1 R02 1
1 RI Recordable indications identified acceptable per ASME Section XI 1
N2B 1 R09 2
2 RI Recordable indications identified acceptable per ASME Section Xl 1
N2B-lR 1R02 1
1 NRI Response to Request for Additional Information Relief Request 13R-14 Request:
Attachment Page 1 1.
Please expand the synopsis of what inspections have already been performed on the components for which this alternative is requested to include all indications that were found and how these indications were dispositioned. If no indications were found during any inspections, please state so.
Response
The following tables identify the Recordable Indications (RI) and Non-Recordable Indications (NRI) identified during the inspections. All the indications were evaluated as acceptable per ASME Section XI.
Table 1 - Unit 1 Nozzle-to-Vessel and Nozzle Inner Radius Ins ection Results 1
N17A 1R04 1
2 NRI 1
N17A 1R07 2
1 NRI 1
N17A-IR 1R04 1
2 NRI 1
N17A-IR 1R07 2
1 NRI 1
N17B 1R04 1
2 RI Recordable indications identified-acceptable per ASME Section XI 1
N17B 1R07 2
1 NRI 1
N17B 1R12 3
1 NRI 1
N17B-IR 1R04 1
2 NRI 1
N17B-IR 1R07 2
1 NRI 1
N17B-IR 1R12 3
1 NRI 1
1R04 1
2 RI Recordable indications identified-acceptable per ASME Section XI 1
N17C 1R11 2
3 NRI 1
N17C-IR 1R04 1
2 NRI 1
N17C-IR 1R11 2
3 NRI 1
N17D 1R04 1
2 RI Recordable indications identified-acceptable per ASME Section XI 1
N17D 1R07 2
1 NRI 1
N17D-IR 1R04 1
2 NRI 1
N17D-IR 1R07 2
1 NRI 1
N2A 1R02 1
1 NRI 1
N2A 1R07 2
1 NRI 1
N2A 1R12 3
1 NRI 1
N2A-IR 1R02 1
1 NRI 1
N2A-IR 1R07 2
1 NRI 1
N2A-IR 1R12 3
1 NRI 1
N2B 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2B 1R09 2
2 RI Recordable indications identified-acceptable per ASME Section XI 1
N2B-IR 1R02 1
1 NRI
Response to Request for Additional Information Attachment Relief Request 13R-14 Page 2 Unit Component Outage Interval Penod Results Misc 1
N2B-IR 1R09 2
2 NRI 1
N2C 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2C 1 R09 2
2 RI Recordable indications identified-acceptable per ASME Section XI 1
N2C-IR 1R02 1
1 NRI 1
N2C-lR 1R09 2
2 NRI 1
N2D 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2D 1R07 2
1 NRI 1
N2D-IR 1R02 1
1 NRI 1
N2D-lR 1R07 2
1 NRI 1
N2E 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section Xl 1
N2E 1R09 2
2 NRI 1
N2E-lR 1R02 1
1 NRI 1
N2E-lR 1R09 2
2 NRI 1
N2F 1 R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2F 1R07 2
1 NRI 1
N2F 1R12 3
1 NRI 1
N2F-lR 1R02 1
1 NRI 1
N2F-IR 1R07 2
1 NRI 1
N2F-IR 1R12 3
1 NRI 1
N2G 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2G 1R07 2
1 NRI 1
N2G 1R11 2
3 NRI 1
N2G-IR 1R02 1
1 NRI 1
N2G-IR 1R07 2
1 NRI 1
N2G-IR 1R11 2
3 NRI 1
N2H 1 R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2H 1R07 2
1 NRI 1
N2H 1R11 2
3 NRI 1
N2H-IR 1R02 1
1 NRI 1
N2H-lR 1R07 2
1 NRI 1
N2H-lR 1R11 2
3 NRI 1
N2J 1R02 1
1 RI Recordable indications identified acceptable per ASME Section XI 1
N2J 1R1O 2
3 NRI 1
N2J-lR 1R02 1
1 NRI 1
N2J-lR 1R1O 2
3 NRI Response to Request for Additional Information Relief Request 13R*14 Attachment Page 2 Recordable indications identified-acceptable per ASME Section XI N2C 1R09 2
2 RI Recordable indications identified-acceptable per ASME Section XI 1R02 1
1 NRI 1R09 2
2 NRI 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1R07 2
1 NRI 1R02 1
1 NRI 1R07 2
1 NRI 1
1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2E 1R09 2
2 NRI 1
N2E-IR 1R02 1
1 NRI 1
N2E-IR 1R09 2
2 NRI 1
N2F 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2F 1R07 2
1 NRI 1
N2F 1R12 3
1 NRI 1
N2F-IR 1R02 1
1 NRI 1
N2F-IR 1R07 2
1 NRI 1
N2F-IR 1R12 3
1 NRI 1
N2G 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2G 1R07 2
1 NRI 1
N2G 1R11 2
3 NRI 1
N2G-IR 1R02 1
1 NRI 1
N2G-IR 1R07 2
1 NRI 1
N2G-IR 1R11 2
3 NRI 1
N2H 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2H 1R07 2
1 NRI 1
N2H 1R11 2
3 NRI 1
N2H-IR 1R02 1
1 NRI 1
N2H-IR 1R07 2
1 NRI 1
N2H-IR 1R11 2
3 NRI 1
N2J 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2J 1R10 2
3 NRI 1
N2J-IR 1R02 1
1 NRI 1
N2J-IR 1R10 2
3 NRI
Response to Request for Additional Information Attachment Relief Request 13R-14 Page 3 Unit Component Outage Interval Period Results Misc.
1 N2K 1 R02 1
1 RI Recordable indications identifled-acceptable per ASME Section Xl 1
N2K 1R1O 2
3 NRI 1
N2K-IR 1R02 1
1 NRI 1
N2K-IR 1R10 2
3 NRI 1
N3A 1R06 1
3 NRI 1
N3A 1R09 2
2 RI Recordable indications identified-acceptable per ASME Section Xl 1
N3A-IR 1R06 1
3 NRI 1
N3A-lR 1R09 2
2 NRI 1
N3B 1R06 1
3 NRI 1
N3B 1R09 2
2 NRI 1
N3B-lR 1R06 1
3 NRI 1
N3B-lR 1R09 2
2 NRI 1
N3C 1R06 1
3 NRI 1
N3C 1R07 2
1 NRI 1
N3C-lR 1R06 1
3 NRI 1
N3C-lR 1R07 2
1 NRI 1
N3D 1R06 1
3 NRI 1
N3D 1R07 2
1 NRI 1
N3D 1R12 3
1 NRI 1
N3D-lR 1R06 1
3 NRI 1
N3D-IR 1R07 2
1 NRI 1
N3D-lR 1R12 3
1 NRI 1
N5A 1R04 1
2 NRI 1
N5A 1R07 2
1 NRI 1
N5A 1R12 3
1 NRI 1
N5A-IR 1R04 1
2 NRI 1
N5A-IR 1R07 2
1 NRI 1
N5A-lR 1R12 3
1 NRI 1
N5B 1R04 1
2 RI Recordable indications identified-acceptable per ASME Section XI 1
N5B 1R07 2
1 NRI 1
N5B 1R12 3
1 NRI 1
N5B-IR 1R04 1
2 NRI 1
N5B-lR 1R07 2
1 NRI 1
N5B-IR 1R12 3
1 NRI 1
N6A 1R05 1
3 NRI 1
N6A 1R1O 2
3 NRI 1
N6A-lR 1R05 1
3 NRI 1
N6A-IR 1R1O 2
3 NRI 1
N6B 1R04 1
2 NRI 1
N6B 1R1O 2
3 NRI 1
N6B-IR 1R04 1
2 NRI Response to Request for Additional Information Relief Request 13R-14 Attachment Page 3 N2K 1R02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 1
N2K 1R10 2
3 NRI 1
N2K-IR 1R02 1
1 NRI 1
N2K-IR 1R10 2
3 NRI 1
N3A 1R06 1
3 NRI 1
N3A 1R09 2
2 RI Recordable indications identified-acceptable per ASME Section XI 1
N3A-IR 1R06 1
3 NRI N3A-IR 1R09 2
2 NRI 1
N3B 1R06 1
3 NRt 1
N3B 1R09 2
2 NRt 1
N3B-tR 1R06 1
3 NRt 1
N3B-tR 1R09 2
2 NRI 1
N3C 1R06 1
3 NRt 1
N3C R07 2
1 NRt 1
N3C-tR 1R06 1
3 NRt 1
N3C-tR 1R07 2
1 NRt 1
N3D 1R06 1
3 NRI 1
N3D 1R07 2
1 NRt 1
N3D 1R12 3
1 NRt 1
N3D-IR 1R06 1
3 NRI 1
N3D-IR 1R07 2
1 NRt 1
N3D-tR 1R12 3
1 NRt 1
N5A 1R04 1
2 NRt 1
N5A 1R07 2
1 NRI 1
N5A 1R12 3
1 NRt 1
N5A-tR 1R04 1
2 NRt 1
N5A-tR 1R07 2
1 NRI 1
N5A-tR 1R12 3
1 NRI 1
N5B 1R04 1
2 RI Recordable indications identified-acceptable per ASME Section XI 1
N5B 1R07 2
1 NRI 1
N5B 1R12 3
1 NRt 1
N5B-tR 1R04 1
2 NRt 1
N5B-IR 1R07 2
1 NRt 1
N5B-IR 1R12 3
1 NRI 1
N6A 1R05 1
3 NRt 1
N6A 1R10 2
3 NRI 1
N6A-IR 1R05 1
3 NRt 1
N6A-IR 1R10 2
3 NRt 1
N6B 1R04 1
2 NRI 1
N6B 1R10 2
3 NRt 1
N6B-IR 1R04 1
2 NRI
Response to Request for Additional Information Attachment Relief Request 13R-14 Page 4 Unit Component Outage Interval Period Results Misc.
1 N6B-IR 1R1O 2
3 NRI 1
N7 1 R05 1
3 RI Recordable indications identified-acceptable per ASME Section XI 1
N7 1R1O 2
3 NRI 1
N7-IR 1R05 1
3 NRI 1
N7-IR 1R1O 2
3 NRI 1
N8A 1R04 1
2 NRI 1
N8A 1R07 2
1 NRI 1
N8A-IR 1R04 1
2 NRI 1
N8A-lR 1R07 2
1 NRI 1
N8B 1R04 1
2 NRI 1
N8B 1R07 2
1 NRI 1
N8B-IR 1R04 1
2 NRI 1
N8B-IR 1R07 2
1 NRI TaLe 2
- Unit 2 Noze-to-Vessel and Nozzle Inner Radius Inspection Results Unit Component Outage Interval Period Results Misc.
2 N17A 2R03 1
2 RI Recordable indications identified acceptable per ASME Section Xl 2
N17A 2R08 2
2 NRI 2
N17A-IR 2R03 1
2 NRI 2
N17A-IR 2R08 2
2 NRI 2
N17B 2R04 1
3 NRI 2
N178 2R10 3
1 NRI 2
N17B-IR 2R04 1
3 NRI 2
N17B-IR 2R10 3
1 NRI 2
N17C 2R02 1
1 NRI 2
N17C 2R07 2
1 NRI 2
N17C-IR 2R02 1
1 NRI 2
N17C-lR 2R07 2
1 NRI 2
N17D 2R04 1
3 NRI 2
N17D 2R09 3
1 NRI 2
N17D-IR 2R04 1
3 NRI 2
N17D-IR 2R09 3
1 NRI 2
N2A 2R02 1
1 RI Recordable indications identified acceptable per ASME Section Xl 2
N2A 2R10 3
1 NRI 2
N2A-IR 2R02 1
1 NRI 2
N2A-IR 2R10 3
1 NRI 2
N2B 2R02 1
1 RI Recordable indications identified acceptable per ASME Section XI 2
N2B 2R07 2
1 NRI 2
N2B-IR 2R02 1
1 NRI Response to Request for Additional Information Relief Request 13R-14 Attachment Page 4 N7-IR N8A N8A N8A-IR N8A-IR N8B N8B N8B-IR N8B-IR 1R05 1R10 1R04 1R07 1R04 1R07 1R04 1R07 1R04 1R07 2
2 2
2 1
2 2
3 3
3 2
2 2
2 1
NRI NRI Rl NRI NRI NRI NRI NRI NRI NRI NRI Recordable indications identified-acceptable per ASME Section XI Table 2 - Unit 2 Nozzle-to-Vessel and Nozzle Inner Radius Ins 2
N17A 2R03 1
2 RI Recordable indications identified-acce table er ASME Section XI 2
N17A 2R08 2
2 NRI 2
N17A-IR 2R03 1
2 NRI 2
N17A-IR 2R08 2
2 NRI 2
N17B 2R04 1
3 NRI 2
N17B 2R10 3
1 NRI 2
N17B-IR 2R04 1
3 NRI 2
N17B-IR 2R10 3
1 NRI 2
N17C 2R02 1
1 NRI 2
N17C 2R07 2
1 NRI 2
N17C-IR 2R02 1
1 NRI 2
N17C-IR 2R07 2
1 NRI 2
N17D 2R04 1
3 NRI 2
N17D 2R09 3
1 NRI 2
N17D-IR 2R04 1
3 NRI 2
N17D-IR 2R09 3
1 NRI 2
N2A 2R02 1
1 RI Recordable indications identified-acce table er ASME Section XI 2
N2A 2R10 3
1 NRI 2
N2A-IR 2R02 1
1 NRI 2
N2A-IR 2R10 3
1 NRI 2
N2B 2R02 1
1 RI Recordable indications identified-acce table er ASME Section XI 2
N2B 2R07 2
1 NRI 2
N2B-IR 2R02 1
1 NRI
Response to Request for Additional Information Attachment Relief Request 13R-14 Page 5 Unit Component Outage Interval Period Results Misc.
2 N2B-lR 2R07 2
1 NRI 2
N2C 2R02 1
1 RI Recordable indications identified acceptable per ASME Section Xl 2
N2C 2R07 2
1 RI Recordable indications identified acceptable per ASME Section Xl 2
N2C-IR 2R02 1
1 NRI 2
N2C-lR 2R07 2
1 NRI 2
N2D 2R02 1
1 RI Recordable indications identified-acceptable per ASME Section Xl 2
N2D 2R10 3
1 NRI 2
N2D-lR 2R02 1
1 NRI 2
N2D-lR 2R10 3
1 NRI 2
N2E 2R02 1
1 RI Recordable indications identified-acceptable per ASME Section Xl 2
N2E 2R07 2
1 NRI 2
N2E-lR 2R02 1
1 NRI 2
N2E-lR 2R07 2
1 NRI 2
N2F 2R02 1
1 RI Recordable indications identified-acceptable per ASME Section Xl 2
N2F 2R07 2
1 NRI 2
N2F-IR 2R02 1
1 NRI 2
N2F-IR 2R07 2
1 NRI 2
N2G 2R02 1
1 RI Recordable indications identified-acceptable per ASME Section Xl 2
N2G 2R07 2
1 NRI 2
N2G-IR 2R02 1
1 NRI 2
N2G-lR 2R07 2
1 NRI 2
N2H 2R02 1
1 RI Recordable indications identified-acceptable per ASME Section Xl 2
N2H 2R09 3
1 NRI 2
N2H-IR 2R02 1
1 NRI 2
N2H-lR 2R09 3
1 NRI 2
N2J 2R02 1
1 RI Recordable indications identified-acceptable per ASME Section Xl 2
N2J 2R09 3
1 NRI 2
N2J-IR 2R02 1
1 NRI 2
N2J-lR 2R09 3
1 NRI 2
N2K 2R02 1
1 NRI 2
N2K 2R10 3
1 NRI 2
N2K-IR 2R02 1
1 NRI 2
N2K-lR 2R10 3
1 NRI 2
N3A 2R03 1
2 NRI 2
N3A 2R07 2
1 NRI 2
N3A-IR 2R03 1
2 NRI 2
N3A-IR 2R07 2
1 NRI Response to Request for Additional Information Relief Request 13R-14 Attachment PageS Recordable indications identified-acce table er ASME Section XI 2
N2C 2R07 2
RI Recordable indications identified-acce table er ASME Section XI 2
N2C-IR 2A02 1
1 NRI 2
N2C-IR 2R07 2
1 NRI 2
N2D 2A02 1
1 RI Recordable indications identified-acceptable per ASME Section XI 2
N2D 2R10 3
1 NRI 2
N2D-IA 2A02 1
1 NAI 2
N2D-IR 2R10 3
1 NRI 2
N2E 2R02 1
1 RI Recordable indications identified-acce table er ASME Section XI 2
N2E 2R07 2
1 NRI 2
N2E-IR 2R02 1
1 NRI 2
N2E-IR 2R07 2
1 NRI 2
N2F 2R02 1
1 RI Recordable indications identified-acce table er ASME Section XI 2
N2F 2R07 2
1 NRI 2
N2F-IR 2A02 1
1 NRI 2
N2F-IR 2A07 2
1 NRI 2
N2G 2A02 1
1 AI Recordable indications identified-acce table er ASME Section XI 2
N2G 2A07 2
1 NRI 2
N2G-IR 2R02 1
1 NRI 2
N2G-IR 2A07 2
1 NRI 2
N2H 2R02 1
1 RI Recordable indications identified-acce table er ASME Section XI N2H 2R09 3
1 NRI R
2R02 1
1 NRI N2H-IR 2R09 3
1 NRI N2J 2R02 1
1 RI Recordable indications identified-acce table er ASME Section XI 2
N2J 2R09 3
1 NRI 2
N2J-IR 2R02 1
1 NAI 2
N2J-IR 2A09 3
1 NRI 2
N2K 2A02 1
1 NRI 2
N2K 2R10 3
1 NRI 2
N2K-IR 2R02 1
1 NRI 2
N2K-IR 2R10 3
1 NRI 2
N3A 2R03 1
2 NRI 2
N3A 2R07 2
1 NRI 2
N3A-IR 2R03 1
2 NRI 2
N3A-IA 2R07 2
1 NRI
Response to Request for Additional Information Attachment Relief Request 13R-14 Page 6 Unit Component Outage Interval Period Results Misc.
2 N3B 2R03 1
2 RI Recordable indications identifled-acceptable per ASME Section Xl 2
N3B 2R07 2
1 RI Recordable indications identified-acceptable per ASME Section Xl 2
N3B-IR 2R03 1
2 NRI 2
N3B-IR 2R07 2
1 NRI 2
N3C 2R04 1
3 NRI 2
N3C 2R09 3
1 NRI 2
N3C-IR 2R04 1
3 NRI 2
N3C-IR 2R09 3
1 NRI 2
N3D 2R04 1
3 NRI 2
N3D 2R09 3
1 NRI 2
N3D-IR 2R04 1
3 NRI 2
N3D-IR 2R09 3
1 NRI 2
N5A 2R03 1
2 RI Recordable indications identified-acceptable per ASME Section XI 2
N5A 2R08 2
2 NRI 2
N5A-IR 2R03 1
2 NRI 2
N5A-IR 2R08 2
2 NRI 2
N58 2R03 1
2 RI Recordable indications identified-acceptable per ASME Section Xl 2
N5B 2R09 3
1 NRI 2
N5B-IR 2R03 1
2 NRI 2
N5B-IR 2R09 3
1 NRI 2
N6A 2R05 1
3 NRI 2
N6A 2R08 2
2 NRI 2
N6A-lR 2R05 1
3 NRI 2
N6A-lR 2R08 2
2 NRI 2
N6B 2R03 1
2 NRI 2
N6B 2R08 2
2 NRI 2
N6B-IR 2R03 1
2 NRI 2
N6B-lR 2R08 2
2 NRI 2
N7 2R05 1
3 NRI 2
N7 2R08 2
2 NRI 2
N7-lR 2R05 1
3 NRI 2
N7-IR 2R08 2
2 NRI 2
N8A 2R03 1
2 NRI 2
N8A 2R10 3
1 NRI 2
N8A-IR 2R03 1
2 NRI 2
N8A-IR 2R10 3
1 NRI 2
N8B 2R03 1
2 NRI 2
N8B 2R10 3
1 NRI 2
N8B-IR 2R03 1
2 NRI 2
N8B-IR 2R10 3
1 NRI Response to Request for Additional Information Relief Request 13R-14 Attachment Page 6 ecordable indications identified-table er ASME Section XI 2
N3B 2R07 2
1 RI Recordable indications identified-acce table er ASME Section XI 2
N3B-IR 2R03 1
2 NRI 2
N3B-IR 2R07 2
1 NRI 2
N3C 2R04 1
3 NRI 2
N3C 2R09 3
1 NRI 2
N3C-IR 2R04 1
3 NRI 2
N3C-IR 2R09 3
1 NRI 2
N3D 2R04 1
3 NRI 2
N3D 2R09 3
1 NRI 2
N3D-IR 2R04 1
3 NRI 2
N3D-IR 2R09 3
1 NRI 2
N5A 2R03 1
2 RI Recordable indications identified-acce table er ASME Section XI 2
N5A 2R08 2
2 NRI 2
N5A-IR 2R03 1
2 NRI 2
N5A-IR 2R08 2
2 NRI 2
N5B 2R03 1
2 RI Recordable indications identified-acce table er ASME Section XI 2
N5B 2R09 3
1 NRI 2
N5B-IR 2R03 1
2 NRI 2
N5B-IR 2R09 3
1 NRI 2
N6A 2R05 1
3 NRI 2
N6A 2R08 2
2 NRI 2
N6A-IR 2R05 1
3 NRI 2
N6A-IR 2R08 2
2 NRI 2
N6B 2R03 1
2 NRI 2
N6B 2R08 2
2 NRI 2
N6B-IR 2R03 1
2 NRI 2
N6B-IR 2R08 2
2 NRI 2
N7 2R05 1
3 NRI 2
N7 2R08 2
2 NRI 2
N7-IR 2R05 1
3 NRI 2
N7-IR 2R08 2
2 NRI 2
N8A 2R03 1
2 NRI 2
N8A 2R10 3
1 NRI 2
N8A-IR 2R03 1
2 NRI 2
N8A-IR 2R10 3
1 NRI 2
N8B 2R03 1
2 NRI 2
N8B 2R10 3
1 NRI 2
N8B-IR 2R03 1
2 NRI 2
N8B-IR 2R10 3
1 NRI
Response to Request for Additional Information Attachment Relief Request 13R-14 Page 7 Reciuest:
2.
Please confirm that the single set of values (e.g., nozzle radii, nozzle thicknesses, etc.) used in Enclosure 2 to l3R-14, Plant Specific Applicability, are correct and applicable to both LGS Units 1 and 2. The staff notes that some of these values would be expected to be unit, or nozzle-specific.
Response
The single set of values (e.g., nozzle radii, nozzle thicknesses, etc.) used in Enclosure 2 to 13R-14, Plant Specific Applicability, are correct and applicable to both LGS, Units 1 and 2. These values are minimum design values.
Response to Request for Additional Information Relief Request 13R-14 Request:
Attachment Page 7 2.
Please confirm that the single set of values (e.g., nozzle radii, nozzle thicknesses, etc.) used in Enclosure 2 to 13R-14, "Plant Specific Applicability," are correct and applicable to both LGS Units 1 and 2. The staff notes that some of these values would be expected to be unit, or nozzle-specific.
Response
The single set of values (e.g., nozzle radii, nozzle thicknesses, etc.) used in Enclosure 2 to 13R-14, "Plant Specific Applicability," are correct and applicable to both LGS, Units 1 and 2. These values are minimum design values.