ML102040769

From kanterella
Jump to navigation Jump to search

the NRC Staff Finds the 6/22/10 Application for Amendment Regarding Containment Spray System Nozzle SR Acceptable for Review
ML102040769
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 07/23/2010
From: Tam P
Plant Licensing Branch III
To: Etheridge H, Waters J
Indiana Michigan Power Co
Tam P
References
TAC ME4125, TAC ME4126
Download: ML102040769 (2)


Text

Accession No. ML102040769 From: Tam, Peter Sent: Friday, July 23, 2010 4:00 PM To: 'hletheridge@aep.com'; 'Joe Waters (jrwaters@aep.com)'

Cc: Lobel, Richard; Torres, Roberto

Subject:

D.C. Cook - 6/22/10 Application for Amendment Acceptable for Review (TAC ME4125 and ME4126)

Helen:

This e-mail informs you that the NRC staff finds your 6/22/10 application (Accession No. ML101880034) for an amendment regarding containment spray nozzle surveillance requirement acceptable for review. The review is currently ongoing under the above two TAC numbers.

Peter S. Tam Senior Project Manager (for D. C. Cook and Monticello)

Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Tel. 301-415-1451 E-mail Properties Mail Envelope Properties (3D6B1F4F51D25E4E9B6C93FF92DAE5171443BF9A23)

Subject:

D.C. Cook - 6/22/10 Application for Amendment Acceptable for Review (TAC ME4125 and ME4126)

Sent Date: 7/23/2010 4:00:14 PM Received Date: 7/23/2010 4:00:00 PM From: Tam, Peter Created By: Peter.Tam@nrc.gov Recipients:

hletheridge@aep.com ('hletheridge@aep.com')

Tracking Status: None jrwaters@aep.com ('Joe Waters (jrwaters@aep.com)')

Tracking Status: None Richard.Lobel@nrc.gov (Lobel, Richard)

Tracking Status: None Roberto.Torres@nrc.gov (Torres, Roberto)

Tracking Status: None Post Office:

HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 8079 7/23/2010 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: